FreeWave ZumLink Z9-PE-DEVKIT Quick Start Manual

Specifications

Brand: FreeWave
Category: Radio
Model: ZumLink Z9-PE-DEVKIT (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the FreeWave ZumLink Z9-PE-DEVKIT Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Z9-PE-DEVKIT Quick Start Guide

Thank you for purchasing the FreeWave ZumLink™ Z9-PE-DEVKIT. This Quick Start Guide provides procedures for the hardware connection and configuration of the Z9-PE-DEVKIT. For detailed information about the Z9-PE-DEVKIT, download the ZumLink Z9-PE User Manual (FreeWave Part Number: LUM0076AA) from http://support.freewave.com/. Warning! The ZumLink Z9-PE-DEVKIT is sold as a fully enclosed device, assembled at the FreeWave factory. Opening the ZumLink Z9- PE-DEVKIT device voids the FreeWave warranty. Included Equipment This is the equipment included with the ZumLink device: Qty Description 2 Z9-PE-DEVKIT wireless device Included with the Z9-PE-DEVKIT 2 ½ Wave 900 MHz Stub Antenna, 2 dBi, SMA Male RF connector (FreeWave Part Number: EAN0900SR) 2 Power Supply: 12VDC @ 800 mA (FreeWave Part Number: EMD1280UW) 2 6.5 foot long shielded Ethernet cable (FreeWave Part Number: ECD0658EB) 2 TNC Male to SMA Female Adapter (FreeWave Part Number: ECN0313TS) 2 Power Adapter (FreeWave Part Number: ASC0002ZL) User-supplied Equipment l USB to micro-USB cable Power Setup of the Z9-PE-DEVKIT The Z9-PE-DEVKIT is approved to operate with an input voltage range of +6 to +30VDC. FREEWAVE Recommends: All input power supply wires should be at least 20AWG wires. A dedicated power supply line is preferred. The power supply used MUST provide more current than the amount of current drain listed in the specifications for the product and voltage. (at least mA at 12V) Warning! Use electrostatic discharge (ESD) protectors to protect the radio from electric shock and provide filtered conditioned power with over-voltage protection. CLI Configuration This procedure provides a Tera Term terminal connection to the ZumLink CLI. The basic steps are: A. Connect the ZumLink to the Computer (on page 1) B. Tera Term Activation and ZumLink Setup (on page 2) Note: The images in this procedure are for Windows® 7 and/or Firefox®. The dialog boxes and windows appear differently on each computer. Connect the ZumLink to the Computer 1. Connect the Z9-PE-DEVKIT to all four connections as shown in Figure 1. The AutoPlay ZumLink, AutoPlay FreeWave Drivers, and ZumLink windows open. Figure 1: AutoPlay ZumLink window Figure 2: AutoPlay FreeWave Drivers window Figure 3: ZumLink window Important!: The ZumLink driver installs automatically. Figure 4: Installing Driver message Figure 5: Driver ready to use message 2. Continue with Tera Term Activation and ZumLink Setup (on page 2). QSG0052AA Rev Oct-2017 Page 1 of 2 Copyright © 2017 FreeWave

Tera Term Activation and ZumLink Setup

Note: The images in this procedure are for Windows® 7 and/or Firefox®. The dialog boxes and windows appear differently on each computer. 1. On the computer connected to the ZumLink device, open a terminal program (e.g., Tera Term http://ttssh2.osdn.jp/). 2. In Tera Term, on the File menu, select New Connection. Figure 6: File menu > New Connection The Tera Term New Connection dialog box opens. 3. Click the Port list box arrow and select the COM port the ZumLink device is connected to. Figure 7: Select the Z9-PE-DEVKIT COM port Important!: The Port assignment varies from computer to computer. 4. Click OK to save the changes and close the dialog box. The Tera Term window shows the connected COM port and Baud rate in the title bar of the window. 5. In the Tera Term window, click the Setup menu and select Serial Port. Figure 8: Serial menu > Setup Port The Tera Term: Serial Port Setup dialog box opens with the default ZumLink settings. Figure 9: Tera Term: Serial Port Setup dialog box with default settings 6. Verify the COM port settings are: Baud Rate: 115200 Data: 8 bit Parity: none Stop: 1 bit 7. Click OK to save the changes and close the dialog box. 8. In the Tera Term window, press . The ZumLink CLI Login returns. 9. Type admin to login and press . 10. When prompted, type admin for the password and press . Note: The password does not appear when typing - it looks blank. The FreeWave Shell returns. Figure 10: The FreeWave Shell returns. 11. At the > prompt, type ip_address=192.168.1.nnn and press . 12. At the > prompt, type nodeId=nnn and press . Note: Where nnn = the same unique 3 digit number. 13. At the > prompt, type save and press . Note: Go to http://support.freewave.com/ to login and download the latest firmware for the Z9-PE-DEVKIT.. Registration is required to use this login. Learn More For additional product information about the Z9-PE-DEVKIT, visit http://support.freewave.com/. For additional assistance, contact a local reseller, or contact FreeWave Technologies, Inc. at 303.381.9200 or 1.866.923.6168, or by email at [email protected]. FreeWave Technologies, Inc. reserves the right to make changes to this document or the product described within it without notice. FreeWave assumes no responsibility or liability for the use of this document or the infringement of any copyright or other proprietary right. The ZumLink Z9-PE-DEVKIT complies with FCC Part 15 rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation. FreeWave Technologies, Inc. 5395 Pearl Parkway, Suite 100 Boulder CO 80301 www.freewave.com Local: 303.381.9200 Toll Free: 1.866.923.6168 Fax: 303.786.9948 QSG0052AA Rev Oct-2017 Page 2 of 2 Copyright © 2017 FreeWave

Other Radio Manuals