C&D Technologies DATEL DMS-EB2 Quick Start Manual

Text of the manual

MPM_DMS-EB2_D00 Page 1 of 4

D I G I T A L P A N E L M E T E R S DMS-EB2 Multi-Purpose Application Board for DMS-20PC/LCD Meters The DMS-EB2 Application Board was designed for quick and easy application/evalu- ation of DATEL's subminiature DMS-20PC/LCD Series, 3½ Digit, LED/LCD Display, Digital Panel Voltmeters. The DMS-EB2's versatility, low cost and direct DMS-20PC/LCD plug-in compatibility makes interfacing a breeze. The DMS-EB2 covers many common panel- meter applications while providing easy signal and power I/O terminations (via a standard MOLEX connector) and plug-in versatility when changing from one application to another. The DMS-EB2 has provisions for such common applications as input dividers for high input voltages, gain (span) adjustment, 9/12Vdc battery operation, and decimal point place- ment. The board permits direct signal I/O wiring via the interface connector or soldering directly to the board. The DMS-EB2 is fully compatible with all four versions of the DMS- 20PC/LCD (±200mV, ±2V, ±20V, ±200V) making it interchangeable from meter to meter and application to application. Solder gaps are conveniently placed on the board and may be quickly bridged or cut as required. This low-cost addition to DATEL's expanding line of subminiature meters dem- onstrates our continuing commitment to offer the most versatile, easy-to-use panel-meter products. FEATURES ■ Gain (span) adjustment ■ Input divider network for attenuating voltages up to 250Vdc ■ Operate meter and board from +5V supply or 9/12V battery ■ On-board solder gaps for decimal point placement ■ On-board I/O connector for easy power and signal input Figure 1. DMS-EB2 Schematic Diagram U1 +VIN +VOUT 1 2 3 4 5 6 SG15 (–) INPUT LO (+) INPUT HI ANALOG� COMMON� TEST/HOLD � REF. OUT REF. IN 12 11 8 7 10 9 SG3 SG2 SG1 DP 3 DP 2 DP 1 +5V SUPPLY/� +BATTERY � 3 4 5 6 2 1 5V RETURN/� –BATTERY � DISPLAY� ENABLE � LM7805CT + C2 10µF 35V GND SG5 C1 1.5µF, 50V SG14 SG10 R2 R1 R3 +5V SUPPLY/� +BATTERY (Close for� Offset Adjust) SG6 SG4 (+) (–) +V GND HI LO TST/� HOLD� IN TST/� HOLD� OUT –V Components are user-supplied � and not part of the standard product SG7-SG9 and SG11-SG13 are not used. J1 J2 Closed solder gap Open solder gap         R1 R2 R5 U1 SG15 SG14 SG6 SG5 J1 SG4 SG3 SG1 SG2 C1 +C2 1 SG10 12 1 2 3 4 5 6 J2 For updated, full-size data sheets visit: www.cd4power.com

M U L T I - P U R P O S E A P P L I C A T I O N B O A R D S F O R D M S - 2 0 M E T E R S

DMS-EB2 MPM_DMS-EB2_D00 Page 2 of 4 D I G I T A L P A N E L M E T E R S www.cd4power.com TECHNICAL NOTES APPLICATIONS 1. LCD Backlighting: To backlight a DMS-20LCD meter, connect J1, pin 3 (TEST/HOLD IN) to J1, pin 6 (GND). This allows for external control, via a switch, of the backlight feature. The switch should be rated for low voltage operation at 35mA. 2. 9V LCD Meters: DMS-20LCD-X-9 meters cannot be used in a single- ended configuration, i.e., with (–) IN LO tied to GND. On these models, both (–) IN LO and (+) IN HI have to be a minimum of 1.5V above and 1.5V below J1 pins 6 and 5, respectively. To operate from a 9V or 12V battery with (–) IN LO tied to GND, use a 5V-powered meter (DMS- 20LCD-X-5), install U1 (LM7805CT) and open SG4. 3. Input Resistor Dividers: Always use 1%, or better, metal-film resistors for R1 and R2, and also make sure their power and voltage ratings are adequate for the given application. 4. Using U1 (LM7805CT): The input power range specified in the Battery Operation section is rated conservatively assuming a 100mA LED meter or a 35mA backlit LCD meter. If a non-backlit LCD model or the low- power LED model is used, the input voltage range can be extended up to 32Vdc. As shipped, the DMS-EB2 is configured for single-ended operation. This configuration is preferred for simple voltage measurements and will gen- erally cover most standard applications. Figure 1 indicates which solder gaps are shipped closed from the factory. Simply solder the board onto the meter (pin 1 to pin 1), connect the power supply to J1, pin 5 (+V) and the power return to J1, pin 6 (GROUND). 1. Decimal Point Placement: DATEL ships the DMS-EB2 with all decimal point solder gaps (SG1, SG2 and SG3) open. To enable a specific deci- mal point, close its respective solder gap with solder. When re-assigning decimal places for subsequent applications, remember to unsolder previ- ously closed solder gaps. Close SG1 for 1.999 (DP1) Close SG2 for 19.99 (DP2) Close SG3 for 199.9 (DP3) 2. Display Test (Not Available on LCD Models): Tie pin 4 (TEST/HOLD OUT) to pin 3 (TEST/HOLD IN) to test the display of the DMS-20PC. Do not leave the meter in the test mode for more than 10 seconds. On LED meters with the HOLD option, tying pins 3 and 4 together freezes the display reading. 3. Battery Operation: Open SG4 and install U1 (LM7805CT) with its metal tab facing to the left as shown in Figure 3. Allowable input power ranges (J1, pins 5 and 6) are as follows: DMS-20PC-X-XS +7.5 to +12.6Vdc DMS-20PC-X-XL +7.5 to +32Vdc C2 (10µF/35V) can be added to reduce noise. Observe correct polarity. Refer to Technical Note 4 for more information. Figure 2. J1 Connector Pinout Pin Function 1 (+) INPUT HI 2 (–) INPUT LO 3 TEST/HOLD IN 4 TEST/HOLD OUT 5 +V (Positive power connection) 6 –V (Ground, negative power return) 1 2 3 4 5 6 � � +V HI� (+) LO� (–) TST/� HOLD� IN TST/� HOLD� OUT –V� GND J1 DMS-EB2 Application board with mating connector and terminals DMS-BZL3 DMS-20 bezel assembly DMS-BZL4 DMS-20 bezel assembly with sealing gasket 39-0304000 LM7805CT (U1), +5V-output, three-terminal regulator 39-2359625 6-position pc-board socket Input Supply Range See applicable meter's data sheet Input Supply Range U1 (LM7805CT) Installed: DMS-20PC-X-XS +7.5 to +12.6V DMS-20PC-X-XL +7.5 to +32.0V DMS-20LCD-X-5 +7.5 to +32.0V DMS-20LCD-X-5B +7.5 to +12.6V Operating and Storage Temperature See applicable meter's data sheet Humidity 0 to 95%, non-condensing Dimensions 1.25" (31.8mm)L x 0.75" (19.1mm)H J1 Connector & Wire Information Terminal Type DATEL P/N 39-2099090 Crimp Tool DATEL P/N 39-2099000 Wire Size 22 to 26 AWG Insulation Diameter 0.062" (1.57mm) max. Stripping Length 0.100" to 0.125" (2.54 to 3.17mm) Ordering Information Functional Specifications (TA = 25ºC) A 10µF/35V tantalum capacitor (C2 on schematic) should be installed with the polarized end next to the + symbol on the DMS-EB2. This is especially important if the power source is located far from U1. 5. Soldering: DATEL recommends the use of "no-clean" solders when making modifications to the DMS-EB2.

M U L T I - P U R P O S E A P P L I C A T I O N B O A R D S F O R D M S - 2 0 M E T E R S

DMS-EB2 MPM_DMS-EB2_D00 Page 3 of 4 D I G I T A L P A N E L M E T E R S www.cd4power.com Figure 3. Installing U1 Figure 4. Installing R1 SG10 12 R3 R1 To measure input voltages greater than ±100Vdc, these two etch paths. open SG10 and also cut SG1 SG2 SG3 1 U1 TO-3-style tab points to left 4. Calibration Adjustment: The DMS-EB2 has provisions for adjusting the calibration of the DMS-20 meter. Calibration adjustment is useful when an input divider (using R1 and R2) is necessary to scale the input voltage. The calibration potentiometer allows "tweaking" of the display reading. Using the calibration potentiometer Adjust the calibration pot on the back of the meter as desired. The adjustment range is only 3/4 of a turn. Do not force the pot past its end stops. 5. Differential Input Signals (Signal Referenced to Power Source): Open SG5. Apply the input signal to pin 1, (+) IN HI, and pin 2, (–) IN LO, of J1. NOTE: Common mode voltage must not exceed ±2Vdc. 6. Measuring Input Voltages Greater than 1.999Vdc (Use DMS-20PC/ LCD-1 Only): CAUTION: Do not exceed 250Vdc input signal. 1. Open SG10. For applications in which input voltages exceed ±100Vdc, also cut the 2 adjoining traces. 2. Calculate values for R1 and R2 as follows: R2 = (FSI x R1) / ( |VIN| - FSI) Where: FSI = The attenuated voltage, between the meter's (–) IN LO and (+) IN HI pins, needed to achieve the desired display readings VIN = Input voltage at J1 (beween pins 1 and 2) A typical value for R1 is 1MΩ. The sum of R1 + R2 should be between 50kΩ and 10MΩ. 3. Enable DP3 by soldering SG3. 4. Calibrate the meter using a known voltage source. Adjust the internal gain potentiometer to compensate for variations in R1 and R2. Example VIN is 199.9Vdc, and the display reading must be "199.9". 1. Assume R1 = 1.0MΩ. 2. R2 = (FSI x R1) / ( |VIN| - FSI) R2 = (1.999 x 1,000,000) / (199.9 - 1.999) R2 = 10101.01Ω or 10kΩ 7. Current Measurements (Use 200mV Model, DMS-20PC/LCD-0): The following instructions are for measuring current derived from the DMS- 20PC/LCD's power source. When measuring current that is floating with respect to J1, pin 6 (GROUND), leave SG5 closed. CAUTION: Do not exceed 1 Ampere input current. 1. Install R2 (R2 = FSR / (IMAX x 10000)) where FSR is the desired reading (0-1999) and IMAX is between 0-1 Ampere. 2. Open SG5. 3. Apply input signal (current) to (+)IN HI and (–) IN LO. 4. Adjust internal gain pot for desired full scale readings. 5. Enable decimal points using either SG1, SG2 or SG3. Example A 1.0 Ampere input must read "1.000" on the display. R2 = 1000 / (1 x 10000) R2 = 0.1 Ohm Enable DP1 via SG1 for reading of 1.000 8. Displaying DMS-20PC/LCD's Power Source (Use DMS-20PC/LCD-2, 5V-Powered Models Only): 1. If the power source is higher than 5Vdc, be sure to install U1 and cut SG4. See Battery Operation section and Technical Note 4. 2. Solder a short piece of jumper wire across the two holes labeled J2. 3. Close SG2 to enable DP2.

M U L T I - P U R P O S E A P P L I C A T I O N B O A R D S F O R D M S - 2 0 M E T E R S

DMS-EB2 DS-0340D 05/2007 © 2006 C&D Technologies, Inc. C&D Technologies, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered C&D Technologies, Inc. trademark. C&D Technologies, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.cd4power.com email: [email protected] ISO 9001 REGISTERED USA: Tucson (Az), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] United Kingdom: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.cd4power.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] MPM_DMS-EB2_D00 Page 4 of 4 D I G I T A L P A N E L M E T E R S For updated, full-size data sheets visit: www.cd4power.com