Argo-Hytos RPEX3-06 Operating Instructions
Text of the manual
RPEX3-06, PRMX2-06, PRMX8-06
RPERX3-06
RPEX3-06*S6
SD1EX-A2
SD1EX-A3
SD2EX-B2, SD3EX-B2
Subject to change · Operating_Instructions_for_Explosion-proof_Valves_4090_2en_06/2018
www.argo-hytos.com
Page 1
RPEX3-06, RPERX3-06, RPEX3-06*S6, PRMX2-06, PRMX8-06,
SD1EX-A2, SD1EX-A3, SD2EX-B2, SD2EX-B3, SD2EX-B4, SD3EX-B2,
SD2PX-B4, PVRMX3-103
Operating Instructions for Explosion-proof Valves
Valve Installation - Dimensions in millimeters (inches)
The minimum dimensions of the manifold must not be below the defined volume.
Heat conductivity of the subplate ≥ 38 W/mK (EN-GJS-500-7)
RPEX3-06 Single valve - min. subplate volume 116 cm3
min. subplate dimensions: 80 x 58 x 25 (3.15 x 2.28 x 0.98)
RPEX3-06 Parallel assembly
Content:
Valve installation
Mechanical part
Electrical part - solenoid
SD*EX-** Single valve - min. housing volume 144 cm3
min. housing dimensions: 60 x 60 x 40 (2.36 x 2.36 x 1.57)
SD*EX-** Screw-in cartridges - parallel assembly
Protection against mechanical damage
The valve must be protected against damage by falling objects with a suitable cover or
a suitable location on the machine or device.
Mechanical Part of the Valve
ATEX/IECEx Classification
The valves equipped with a explosion-proof single stroke solenoid are available
with the following certifications and protection modes:
Certificate No.: EPS14ATEX1744 X
Certificate No.: IECEx EPS14.0064 X
AC
l M2 Ex mb I Mb
Ex mb I Mb
lI 2G Ex mb IIB T4, T5, T6 Gb
Ex mb IIB T4, T5, T6 Gb
lI 2D Ex mb IIIC T135 °C, T100 °C, T85 °C Db Ex mb IIIC T135 °C, T100 °C, T85 °C Db
DC
l M2 Ex e mb I Mb
Ex e mb I Mb
lI 2G Ex e mb IIB T4, T5, T6 Gb
Ex e mb IIB T4, T5, T6 Gb
lI 2D Ex tb IIIC T135 °C, T100 °C, T85 °C Db Ex tb IIIC T135 °C, T100 °C, T85 °C Db
Marking
II 2GD Ex h IIB T4...T6 IIIC T135 °C, T100 °C, T85 °C
I M2 Ex h
Subject to change · Operating_Instructions_for_Explosion-proof_Valves_4090_2en_06/2018
www.argo-hytos.com
Page 2
Electrical Part of the Valve
0408
Registry-No. of above authority: 0408
Declaration of conformity: K 19 / 2014
Document: B 32 / 2014
Data as of: 03.06.2014
1. Introduction
The solenoid was designed, manufactured, and tested in compliance with the standards and
regulations generally applicable within the European Union. On leaving the factory,
the solenoid‘s safety-related conditions were tested and proven to be faultless.
The operator must read and observe the notes and warnings provided with these operating
instructions to maintain this status and to ensure safe operation.
The solenoid must only be installed and wired by a qualified technician, who is familiar with and
works according to the generally accepted engineering standards and the latest legal regulations and
standards of explosion protection.
Surface treatment - Solenoid is zinc-coated with surface protection
acc. to ISO 9227 (520 h salt spray).
2. Usage
This solenoid is assigned to Group II, Category 2 of the ATEX directive and to Group I,
Category M2 for mining applications.
This device can be used in areas where explosion hazard occurs through:
- gas/air mixtures, vapours or mists of flammable materials
according to classes IIA and IIB acc. ATEX and IECEx.
- flammable dust/air mixtures
according to classes IIIA, IIIB and IIIC.
This device may be used in the following explosion hazard areas outside mining:
Zone 1, Zone 2, Zone 21 and Zone 22.
The maximum ambient temperatures are as follows:
Temperature class
T6 or rather T 80 °C (176 °F): Tamb= -30 °C (-22 °F) up to +45 °C (113 °F) and coil power Pn=10 W
T5 or rather T 95 °C (203 °F): Tamb= -30 °C (-22 °F) up to +55 °C (131 °F) and coil power Pn=10 W
T4 or rather T130 °C (266 °F): Tamb= -30 °C (-22 °F) up to +70 °C (158 °F) and coil power Pn=10 W
T4 or rather T130 °C (266 °F): Tamb= -30 °C (-22 °F) up to +60 °C (140 °F) and coil power Pn=18 W
For 110 V DC, 110 V AC and 230 V AC coils:
The valve coil is not intended for direct connection to an electrical distribution network. Interference filtering up to 30 MHz and surge protection
must be provided by the manufacturer of the device on which the valve is installed.
3. Solenoid Ordering Code
Explosion-proof solenoid,
inner diameter 22 mm
Housing size
DC voltage
connection box
+ Cable gland
AC voltage 50/60 Hz
fix installed cable
Solenoid nominal power
10 W
18 W
Cable length
no cable (only for DC)
cable 3 m
cable 8 m
Temperature class
for 10 W, 18 W
for 10 W only
No designation
3M
8M
Solenoid Codes
Ordering No.
Solenoid Codes
Ordering No.
Solenoid Codes
Ordering No.
EX22-46/01200AT4-B
32754300
EX22-460/1200BT4-B
32755000
EX22-46/23050AT4-3M-B
32756000
EX22-46/01200AT6-B
32754400
EX22-46/02400BT4-B
32755300
EX22-46/23050AT4-8M-B
32756100
EX22-46/02400AT4-B
32041400
EX22-46/04800BT4-B
32755400
EX22-46/23050AT6-3M-B
32756200
EX22-46/02400AT6-B
32754500
EX22-46/11000BT4-B
32755500
EX22-46/23050AT6-8M-B
32756300
EX22-46/04800AT4-B
32754600
EX22-46/11050AT4-3M-B
32755600
EX22-46/11050BT4-3M-B
32756400
EX22-46/04800AT6-B
32754700
EX22-46/11050AT4-8M-B
32755700
EX22-46/11050BT4-8M-B
32756500
EX22-46/11000AT4-B
32754800
EX22-46/11050AT6-3M-B
32755800
EX22-46/23050BT4-3M-B
32756600
EX22-46/11000AT6-B
32754900
EX22-46/11050AT6-8M-B
32755900
EX22-46/23050BT4-8M-B
32756700
EX22-46/
-
-
01200
02400
04800
11000
11050
23050
A
B
12 V DC
24 V DC
48 V DC
110 V DC
110 V AC
230 V AC
T4
T6
Surface treatmen
zinc-coated (ZnNi), ISO 9227 (520 h)
B
Subject to change · Operating_Instructions_for_Explosion-proof_Valves_4090_2en_06/2018
www.argo-hytos.com
Page 3
1
2
coil
gn/ye
1
2
coil
gn/ye
4. Electrical Data - Version A and B
› Rated voltage: Un [V DC] ±10 % max.
› Supply voltage: Un [V DC or V AC] for electronics
› Ripple voltage: ±15 %
› Resistance: R20 [Ω] ±5 % at 20 [°C]
› Working duty: S1 (100 % ED) in mounted state with valve
Table 2: Voltage versions A and B
Type
Voltage
Resistance
Nominal current
Limiting current
Protection concept
Power
Un
R20
In
IG
Pn
[VDC]
[Ω]
[A]
[A]
[W]
xx EX18 046A A012
12
16.1
0.75
0.65
Diode (36V)
8.9
xx EX18 046A A024
24
61.8
0.39
0.34
Diode (36V)
9.3
xx EX18 046A A048
48
252.4
0.19
0.16
Diode (75V)
9.1
xx EX18 046A A110
110
1171.5
0.094
0.08
Diode (180V)
10.3
xx EX18 046B A012
12
7.7
1.56
1.37
Diode (36V)
18.8
xx EX18 046B A024
24
32.3
0.74
0.65
Diode (36V)
17.8
xx EX18 046B A048
48
125.7
0.38
0.33
Diode (75V)
18.3
xx EX18 046B A110
110
655.6
0.17
0.15
Diode (180V)
18.5
[VAC] 50/60 Hz
xx EX18 046A B110
110
894.1
0.112
0.095
Bridge rectifier
11.2
xx EX18 046A B230
230
3987
0.052
0.044
Bridge rectifier
10.7
xx EX18 046B B110
110
524.4
0.19
0.167
Bridge rectifier
19.1
xx EX18 046B B230
230
2251.4
0.092
0.08
Bridge rectifier
19
5. Initial Installation
› The ambient temperature range shall not exceed the temperatures given in chapter 2. The maximum temperature of the medium
(generally hydraulic fluid) shall not exceed 70 °C (158 °F).
› It is the user’s duty to ensure free and unhindered heat emission during operation. This means that the solenoid shall neither be covered
nor stored immediately adjacent to heat sources (e.g. fan heaters) during operation.
› The solenoid shall not be subjected to direct sunlight during operation.
6. Installation - Installation, Mounting, Demounting
› Using the V DC type for temperature class T4 requires a cable with an operating temperature limit of at least +105 °C (221 °F), e.g. LAPP
FD Robust. T5 and T6 require a cable with an operating temperature limit of at least +90 °C (194 °F). The fastening torque on the cable
gland depends of the used cable and is to be determined by the installing user.
› When installing the V DC solenoid, the fastening torque of the screws shall be [4 Nm (2.95 lbf.ft)] and for the BARTEC connection box
[0.4 Nm (0.30 lbf.ft)].
› When installing the V DC solenoid, an appropriate cable shoe of size M3 with a crosssectional area of 0.75 mm2 with an operating
temperature limit of at least +105 °C (221 °F) is to be used.
› The user has to safeguard each solenoid with a fuse: Ip ≤ 3xIG, with trigger characteristic “slow blow”. (IG values see Operating
Instructions - Table 2). The breaking capacity of the fuse link has to be stronger than the maximum short circuit current
at the user’s operating area.
› EX-secured components must be used during mounting in case the fuse and/or the interface are within the EX-range.
› The solenoid may be connected to ground via the purpose-built ground clamp on the connector casing.
› The EX-solenoid shall only be operated with a valve body according to the instructions in chapter 12.
› The coil must not be activated alone – a connection to the valve body is required!
› The single parts needed for assembly are listed in chapter 13.
7. Specification
› Coils and plug cavity with watertight encapsulation. Temperature class of coil “F“ [155 °C (311 °F)]
› Protection type IAW DIN VDE 0470, EN 60529 and/or IEC 529, device: IP 65
› Surface protection (casing) acc. DIN 50979 Fe//Zn8-12//Cn//T0
› Max. temperature of the operating medium (generally hydraulic fluid): 70 °C (158 °F)
› Max. ambient temperature: see chapter 2!
8. Suppressor - Connection Diagrams
Figure 2 - Bridge rectifier for AC version
Figure 1 - Bidirectional voltage limiter – diodes:
Uz = 36 V, bipolar for Un = 12 und 24 V DC
Uz = 75 V, bipolar for Un = 48 V DC
Uz = 180 V, bipolar for Un = 110 V DC
*Limiting curent (IG) - current at the highest temperature.
Subject to change · Operating_Instructions_for_Explosion-proof_Valves_4090_2en_06/2018
www.argo-hytos.com
Page 4
46,2 (1.82)
26 (1.02)
22 (0.87)
Valve tube
O-Ring
21.89x2.62 MVQ70
5+1 Nm
(3.7+0.7 lbf.ft)
9. Maintenance, Service, Troubleshooting
› The solenoid generally requires almost no maintenance. All electrical connections shall be checked regularly for possible damages (visual check).
› The surface of the device shall be checked regularly for dust deposits, which should be cleaned off.
› Do not try to open or to repair the device. If any trouble occurs, please contact the manufacturer.
10. Standards and Regulations
› Directive 2014/34/EU of the European Parliament and the European Council (ATEX 95)
› DIN VDE 0580
› EN 60529
› EN 60079-0:2012, EN 60079-7:2007, EN 60079-18:2009, EN 60079-31:2009
› IEC 60079-0:2011, IEC 60079-7:2006, IEC 60079-18:2009, IEC 60079-31:2008
11. Safety Notice - Please Read Carefully!
› In case the solenoid shows any signs of a defect, malfunctioning or external damage.
(including corrosion), the device must immediately be taken out of operation.
› Any deposits on the surface of the device shall not obstruct heat emission.
› To maintain legibility of the data plate, the solenoid must not be coated.
Caution:
› Always disconnect the solenoid from the power supply before any maintenance or other work on it.
› Always exchange the complete solenoid. Do not try to repair the solenoid.
› Under no circumstances shall any changes be made to the solenoid or the connecting cable.
› Never operate the solenoid when disconnected from the valve body.
› Demount the solenoid only in secure areas (not in EX-areas). If this is not possible, the solenoid must cool off for at least 10 minutes.
Any warranty claims are denied in case the regulations in this operating manual are not observed!
12. Grouping of Single Solenoids and Valves
Instructions – Please Read Carefully!
› If two solenoids per valve body are installed (RPEX3-06), they have to be mounted on opposite sides.
› The user has to ensure only one solenoid per valve body is actuated at a time. Simultaneous activation of solenoids at one and the same
valve body is forbidden. The user has to fulfil this requirement by proper electrical connections.
General
› A single solenoid must only be operated with a valve body within at least a minimum volume described in “Valve Installation”.
› The valves are wrapped in polyethylene bags (vacuum packed) and fitted with paper labels bearing the product number, name
and manufacturing order.
› The valves should be stored in boxes and protected against weather influences that may cause corrosion.
› Except for the replacement of the external gasket, any other repairs of the valve are prohibited.
They may be carried out at the manufacturer’s only.
13. Dimensions in millimeters (inches)
14. Transport and Storage / Service and Maintenance
PRODUCER:
ARGO-HYTOS s.r.o.
Dělnická 1306
543 15 Vrchlabí, Czech Republic
Telefon: + 420 499 403 111
Internet: www.argo-hytos.com
E-mail: [email protected]