Bticino 321071 Manual 

Specifications

Brand: Bticino
Category: Touchscreen
Model: 321071 (Manual )
File Type: PDF
File Size: —
Pages: 5

Read Online

Read the Bticino 321071 Manual  online using the built-in PDF viewer.

Text of the manual

3 4 5

6 9 87 14 15 16 17 18 11 12 13 19 20 21 D45 System 10” touch screen handsfree internal unit BT00852-a-EN 03/09/2014 Description D45 System 10” touch screen video internal unit. Complete door entry functions with alarm managements. International standard SOS pushbutton, intercom function, programming device touch screen functions. Digital photo frame and camera functions. Direct call to switchboard function. 6 different default selectable ringtones (can be changed with your favourite music). Slot for SD CARD. Surge protection. Wall mount installation. Power supply : 18-30 Vdc Stand by absorption: ≤ 100 mA @ 30 V Max. operating absorption: ≤ 200 mA @ 30 V Operating temperature: (-10)-(+40)°C LCD display size : 10.2” LCD display resolution : 800 x 480 Supported SD CARD : 32 Gb maximum Supported music files : mp3, wav, wma Dimensional data Legend 1. Mini USB port 2. SD CARD socket 3. Message information LED 4. Connection status LED 5. Alarm LED 6. Microphone 7. Door lock release pushbutton 8. Communication pushbutton 9. SOS pushbutton 10. 10” LCD touch screen display 11. Download connector 12. Configurator housing 13. Local power connector 14. Anti removal alarm sensor connector 15. SOS alarm connector 16. SEP entrance panel connector 17. Alarm sensor connector 18. Unlock device connector 19. RJ45 System BUS connector 20. Anti removal switch 21. Loudspeaker Front & side views Rear view Technical data

10” touch screen handsfree internal unit

BT00852-a-EN 03/09/2014 F F I I #I #I Configuration When the biggest number of #FF in whole system is ≤ 20, and the biggest number of #II is ≤4, and the total risers number is ≤ 50, we recommend to choose (MODE 1) configuration for system. When the biggest number of #FF in whole system is more than 20, or the biggest number of #II is more than 4, we suggest to use (MODE 2) configuration to setup #FF (choose the biggest number #FF of system) and #II (choose the biggest number #II of system), then calculate total IU number of system. If the total number (#FF * #II * R ) is less or equal 4000, use of (MODE 2) is suggested. Indoor handset must be configured for following parameters: FF : Floor number II : Apartment number #II : Maximum apartments quantity per floor in a riser Two different configuration modes available for whole system: configuration MODE 1 and configuration MODE 2. The main characteristics for each configuration mode are listed below. POSITION MOde 1 MOde 2 F FF FF F I II II I #I Default for #II is 04, need not connect the configurator II (#II setup using same value for all system handsets). #I Two different device configuration ways available: WAY 1: configuration settings by touch screen WAY 2: configuration setting by inserting physical configurators Configuration setting by touch screen - WAY 1 : At the lower right corner of the main interface, press on the icon, you will enter in the setting page. Click on the icon, to input the installation password (default password : 686868) and click on the (OK) icon to confirm, you will come to the installation page. Note : when you come to the sub menu, click on the white circle at front of the setting item, if selected there is a red dot in the white circle. When you operate with the digital keyboard, click on the (C) icon to delete the last number; click on the (OK) icon to confirm Room Number Lift SOS Detector IU Type Entry Panel Restore Home Back

10” touch screen handsfree internal unit

BT00852-a-EN 03/09/2014 Room Number IU Type Configuration Click on the white circle to select “With apartment interface 323009” or “Without apartment interface 323009”. If you select “With apartment interface 323009”,you can’t set the room number because this is directly set by the apartment interface. If you select “With apartment interface 323009, two modes are available: direct call mode and normal call mode. With direct call mode, the room number is a digital value (1 to 4000). With normal call mode, the room number is a combination of floor number and room number. You need to set the room number and the maximum apartment quantity per floor. Click on the white circle to select “With lift controller” or “Without lift controller”. If you select “With lift controller”, a lift icon will appear in the main interface. In idle state, press this icon or the unlock key to call the lift. Note : lift control function should be equipped with a lift controller interface and supported by the lift manufacturers. Default setting is without lift controller. Click on the white circle to select SOS alarm contact status “Normal open” or “Normal close”. Default setting is Normal open. The alarm detector sub menus include two pages, the setting item in the first page as below : Enable /Disable : enable or disable the detector, click on the “Enable” or “Disable” to switch enable /disable. Detector mode : set the detector normal open or normal close, select “ON” (normal open) or “OFF” (normal close) to switch detector mode. Definition : define the detector type, (area1-infrared), (area2-door contact), (area3- smoke), (area 4-gas), (area5-infrared/no infrared), (area 6- infrared/no infrared), (area 7- infrared/no infrared), (area 8- infrared/no infrared), click on the “infrared” or “no infrared” to switch detector definition of area 5 to area 8. Area1 to area 4 can’t be changed. Status : display the detector status, when it becomes blue detector is enabled and when it becomes gray means disabled. Areas : show area1 to area 8 alarms. Click on “Reset” to restore the parameters of the page to default value. Click on the PgDn icon to have access to the second page. Setting item in the second page as below: Alarm : define alarm whether with sound, click on the white circle to select “YES/ON”. Effective time for alarmed : click on the white circle to set the effective time as 40 sec./100 sec./150 sec./210 sec./225 sec. Delay : when the detector monitors an alarm, it will report the message after the setting delay time. You can click on the white circle to set the delay time as 40 sec./100 sec./150 sec./210 sec./225 sec. For Area 3 and Area 4 you can’t set delay time. Click on “reset” to restore the parameters of the page to default value. Click on the PgUp icon to return to the first page Lift Entry Panel SOS Restore Detector Click on the white circle to select “Master” or “Slave” IU. When one apartment install multiple handsets, if the handsets be called, only the master handset opens the video, slave handsets do not open the video. If the slave handset answered, the other handset returns to static, the answered handset open the video and audio, and then you can talk with the entry panel. Default setting is master handset. Click on the white circle to select “Doorbell” or “Entry panel”. If the handset linked is a small entry panel, we can set whether monitor the small entry panel, if you select “Monitor enable”, “Video door phone” menu will display “ ”. When the small entry panel call handset, the handset will ring and turn on the video; if linked with doorbell ,it can’t monitor and when the handset detect income signal the handset only ringing for 10 seconds. Click on “OK” to restore all the parameters to default value or click on “Cancel” to abort your operation.

10” touch screen handsfree internal unit

BT00852-a-EN 03/09/2014 Configuration example (A): The number of handsets is 1204, each floor has 4 handsets, the system configuration mode is Mode 1, the handset configuration should be as follows POSITION CONFIGURATION VALUE REMARkS F 1 F 2 I 0 It is ok not to insert configurator 0 I 4 #I Because the default value of #II is 4, no configurator is needed #I example (B): The number of handsets is 1206, each floor has 8 handsets. System configuration mode 2 is used. The handset configuration should be as follows: POSITION VALUE REMARkS F 1 F 2 I 0 It is ok not to insert configurator 0 I 6 #I 0 It is ok not to insert configurator 0 #I 8 Configuration setting by inserting phisical configurators - WAY 2 : Side pushbutton functions SOS Key : in case of urgent or unexpected situation, press on the “SOS key” to send the alarm message to the management center. Answer Key : When a visitor calls the host, press the “Answer key” to talk with him, during which you can press again on the key to end the talk. Unlock Key : During the communication with the entrance panel or the small entrance panel, press on the “Unlock key” to unlock and call the lift. Icons quick explanations F F I I #I #I Back Return to previous menu Home Return to the main interface PgUp Page up PgDn Page down Anti-disturb mode, the status Led on (red) Outside mode, the status Led on (pink) Home mode, the status Led on (blue)

10” touch screen handsfree internal unit

LED indicators IU device supports an SD CARD (32 Gb max.). The icon pops up at the up-right angle of the screen, meaning that the storage card has been inserted. When inserted, sound and image media contents can be used. Supported audio format : MP3, WAV, WMA. Supported images format : JPG, BMP. Device can be connected to a PC by using an universal USB cable in order to share music and photos. PC must be equipped with the USB 2.0 and one of the following operating systems : MAC OS X v10.5.8 or higher version Windows 7, Windows Vista or Windows XP Home or Professional(SP3). SD Card storage Device connection LED Status of the internal unit Status LED Red ON Anti disturb mode Blue ON Common mode Pink ON Outside mode Red Quick flash Being called, no answer Red Slow flash Talking Information LED Off Dim No new message Blue Quick flash New message Alarm LED Off DIM Unguarded Red Slow flash Guarded, without alarm Red Quick flash Alarm occurs BT00852-a-EN 03/09/2014

Other Touchscreen Manuals