DIGITAL TIME SWITCH
●
Can set 20 groups on-off program, cycle weekly or daily, and control on-off manually
●
Can set 20 groups pulsation program, cycle weekly or daily, and control on-off manually
●
With countdown function, time range setting within 1 s ~ 99min 59sec
●
Can set Daylight Saving Time (1Hours) manually
●
Built-in lithium battery, and t
2.Timing settings (2.1,2.2 and 2.3 three functions can not be used at the same time)
2.1 20 groups setting of on/off function:
Step
Button
Programming
1
Press
Enter into timing ON setting (display 1 ON)
2
Press H+ and M+
Set ON time, press H + to set the hour, press M + to set the minute
3
Press D+
Same setting every day, MO-FR, MO-SA, SA-SU, MO-WE, TH-SA,
Note: This setting only set present time displayed. The ON/OFF time of program or pulsation has been set is not changed. If the ON/OFF
program needs to run according to DST, set it in the setting program.
Automatic correction of time error daily("1d"display at bottom left corner of screen)
Step
Button
Programming
1
Press both MANUAL and
Enter into time c