Multi-tone Open-area Alarm Devices

Installation Guide General This guide describes the installation of the following products: Part No Product Name Type Colour 55000-278 Multi-tone Open-area Sounder Indoor (Type A) Red 55000-279 Multi-tone Open-area Sounder Indoor (Type A) White 55000-274 Multi-tone Weatherproof Open-area Sounder Outdoor (Type B) Red 55000-275 Multi-tone Weatherproof Open-area Sounder Outdoor (Type B) White 55000-293 Multi-tone Open-area Sounder with Visual Indicator and Isolator* Indoor (Type A) Red 55000-294 Multi-tone Open-area Sounder with Visual Indicator and Isolator* Indoor (Type A) White 55000-291 Multi-tone Open-area Sounder with Visual Indicator* Indoor (Type A) Red 55000-292 Multi-tone Open-area Sounder with Visual Indicator* Indoor (Type A) White 55000-298 Multi-tone Weatherproof Open-area Sounder with Visual Indicator and Isolator* Outdoor (Type B) Red 55000-299 Multi-tone Weatherproof Open-area Sounder with Visual Indicator and Isolator* Outdoor (Type B) White 55000-296 Multi-tone Weatherproof Open-area Sounder with Visual Indicator * Outdoor (Type B) Red 55000-297 Multi-tone Weatherproof Open-area Sounder with Visual Indicator * Outdoor (Type B) White * This is a supplementary indicator and is not to be used where a VAD is speci� ed. This product in not EN54-23 compliant. The Multi-tone Open-area Alarm Devices are connected to control panels which use the Discovery or XP95 protocol. It complies with the requirements of EN54–3: 2001. Versions with isolator also comply with EN54–17: 2005. Tones incorporated in the product are: Apollo Standard Tone, Slow Whoop Tone to NEN2575 and DIN 33404 Tone. There are 2 volume settings in each variant. The versions which incorporate a short-circuit isolator have a yellow indicator LED, which illuminates through the lens if a short circuit is detected on the loop wiring. Mounting the Backbox The backbox is removed by using either an unlocking key (Type A versions) to press in one of the retain- ing lugs, or a hex driver (Type B versions). The Type A product has 6 slotted knockouts on the backbox and is installed directly to the mounting surface. For the Type B product, � t the backbox to the mounting surface with four screws using the holes in each corner (see Fig 1). Do not drill through the backbox. To ensure that there is a good seal between the back box and the unit, the mounting surface should be as � at as possible and the mounting screws not over tightened. Wiring Details Note: This product is polarity sensitive (supply reversal protected) and will not function if wired incor- rectly. Drill holes for cable entry as appropriate for the installation. Drill guides are marked on the backbox. To maintain the integrity of the Type B product it is essential that suitable cable glands be used. Connect the loop cables to the terminal block, observing polarity and functional earth/screen if appli- cable. The wiring terminals accept solid or stranded cables up to 2.5mm². The maximum number of Multi-tone Open-area Alarm Devices permitted between standard XP95 isolators (part no. 55000-720) or isolating bases (part no. 45681-321/284) is 20, depending on the loop loading. Apollo's Loop Calculator is a program available as a free download from www.apollo-� re. co.uk and can be used to check the loading of any proposed loop design. PP2248/Issue 11 ©Apollo Fire Detectors Ltd 2003–2018 Apollo Fire Detectors Ltd, 36 Brookside Road, Havant, Hants, PO9 1JR, UK Tel +44 (0)23 9249 2412 Fax +44 (0)23 9249 2754 Email: techsales@apollo-� re.co.uk Website: www.apollo-� re.co.uk Group Address Setting In group mode the Multi-tone Open-area Alarm Devices responds to an additional address referred to as the group address, which is used to activate groups of sounders simultaneously. Individual units con- tinue to respond to their own addresses and report their status in the normal way. A group address is set on a four-segment DIL switch which is factory set to 0000. A group address may be any spare address within–and only within–the range 112 to 126 inclusive. The required group address is set in accordance with the following table. DIL switch DIL switch DIL switch setting setting setting addr 1234 addr 1234 addr 1234 112 1111 117 0101 122 1010 113 0111 118 1001 123 0010 114 1011 119 0001 124 1100 115 0011 120 1110 125 0100 116 1101 121 0110 126 1000 Note: group mode is disabled if the group address DIL switch is set to 0000, irrespective of the protocol message. Commissioning It is important that the Multi-tone Open-area Alarm Devices be fully tested after installation. An XP95 Test Set, part no. 55000-870, may be used to carry out func tion al testing of individual units. The test set can also perform data integrity tests of an entire system. Troubleshooting Before investigating individual units for faults, it is important to check the system wiring is fault-free. Earth faults on data loops may cause communication errors. Fault Finding Problem Possible Cause No response or missing Incorrect address setting Incorrect loop wiring (polarity reversed) Too many Sounders with Visual Indicator between isolators Analogue value 2 Visual Indicator failed (Sounder with Visual Indicator version only) Analogue value 4 Incorrect group or individual address setting Device fault Incorrect group address setting Device fails to operate Control panel has incorrect cause and effect programming Incorrect group address setting Locking Mechanism To meet the requirements of EN54 Part 3 and the Construction Products Directive, the devices have been designed to lock to its base. To release the Type A device from its base, a release key (supplied) must be used to release the latch in the side of the base. To unlock the Type B (Weatherproof) versions, a hex driver (supplied) is required.

Maximum Loop Current Consumption at 24V

Switch-on Surge 1.2mA for <1 sec Quiescent 330µA Sounder Operated 4mA Max Sounder Beacon Operated: 92/100dB(A) 9mA Max Sound Output 100dB(A) IP Rating - Type A 21C IP Rating - Type B IP33C (IP66C**) ** Non EN 54 certi� ed For sound pressure levels measured to EN54–3 see document PP2203 and for isolator operation informa- tion see document PP2090, both available on request. IP Rating To maintain the integrity of the enclosure it is essential that suitable IP rated cable glands be used. Individual Address Setting The address of the Multi-tone Open-area Alarm Devices is set using seven segments of the eight-seg- ment DIL switch. The eighth seg ment is used to adjust the volume output. Segments 1-7 of the switch are set to “0” (ON) or “1”, using a small screwdriver or similar tool. A complete list of address settings is shown below. DIL switch DIL switch DIL switch DIL switch DIL switch setting setting setting setting setting addr 1234567 addr 1234567 addr 1234567 addr 1234567 addr 1234567 1 1000000 11 1101000 21 1010100 31 1111100 41 1001010 2 0100000 12 0011000 22 0110100 32 0000010 42 0101010 3 1100000 13 1011000 23 1110100 33 1000010 43 1101010 4 0010000 14 0111000 24 0001100 34 0100010 44 0011010 5 1010000 15 1111000 25 1001100 35 1100010 45 1011010 6 0110000 16 0000100 26 0101100 36 0010010 46 0111010 7 1110000 17 1000100 27 1101100 37 1010010 47 1111010 8 0001000 18 0100100 28 0011100 38 0110010 48 0000110 9 1001000 19 1100100 29 1011100 39 1110010 49 1000110 10 0101000 20 0010100 30 0111100 40 0001010 50 0100110 51 1100110 61 1011110 71 1110001 81 1000101 91 1101101 52 0010110 62 0111110 72 0001001 82 0100101 92 0011101 53 1010110 63 1111110 73 1001001 83 1100101 93 1011101 54 0110110 64 0000001 74 0101001 84 0010101 94 0111101 55 1110110 65 1000001 75 1101001 85 1010101 95 1111101 56 0001110 66 0100001 76 0011001 86 0110101 96 0000011 57 1001110 67 1100001 77 1011001 87 1110101 97 1000011 58 0101110 68 0010001 78 0111001 88 0001101 98 0100011 59 1101110 69 1010001 79 1111001 89 1001101 99 1100011 60 0011110 70 0110001 80 0000101 90 0101101 100 0010011 101 1010011 106 0101011 111 1111011 116 0010111 121 1001111 102 0110011 107 1101011 112 0000111 117 1010111 122 0101111 103 1110011 108 0011011 113 1000111 118 0110111 123 1101111 104 0001011 109 1011011 114 0100111 119 1110111 124 0011111 105 1001011 110 0111011 115 1100111 120 0001111 125 1011111 126 0111111 Fig 3. Example of address and tone setting Tone Setting 5 6 Tone 0 0 Standard 1 0 Slow Whoop 0 1 DIN 1 1 Standard The alert or evacuate mode is selected using the appropriate settings on the CIE (Control & Indicating Equipment Fig 2. Wiring Fig 1. Mounting Type B weatherproof products

Other Security System Manuals