Extech Instruments AN100 Operation & User’s Manual
| Brand: | Extech Instruments |
| Category: | Measuring Instruments |
| Model: | AN100 (Operation & User’s Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 10 |
Text of Extech Instruments AN100 Operation & User’s Manual
CFM/CMM Thermo Anemometer
Model AN100
www.GlobalTestSupply.com
Find Quality Products Online at:
[email protected]
Extech Instruments AN100 Congratulations on your purchase of the Extech AN100 CFM/CMM Thermo Anemometer. This
instrument measures Air Velocity, Air Flow (volume) and Temperature. The large, easy-to-read
backlit LCD includes primary and secondary displays plus numerous status indicators. The
meter is shipped fully tested and calibrated and with proper use will provide years of reliable
service.
Descriptions
1.
LCD Display
2.
Vane Probe
3.
Rubb
• AUTO POWER OFF Press to turn the meter ON or OFF
• MAX/MIN (for Airflow/Air Velocity) Used to record and store the highest, lowest and average
airflow or velocity readings.
◄ (LEFT) also serves as change decimal point button in AREA mode
• UNITS Press to select the mode of operation. In FLOW mode, the meter displays air volume. In
VELOCITY mode, the meter displays air speed.
▲(UP) also serves as increase n
MAX (top of LCD): Max Hold function engaged for the Air Temperature function
HOLD (top of LCD): Data Hold function engaged for the Air Temperature function
VEL: indicates that meter is in air velocity mode
FLOW: indicates that meter is in air flow mode
MAX (bottom of LCD): Max Hold for the IR Temperature and RH function
HOLD (bottom of LCD): Data Hold for the IR Temperature function and RH function
Extech Instruments AN100 Connecting the Vane
1. The vane plug is inserted in the meter’s sensor jack at the top of the meter. The plug and jack
are keyed so that the plug can only fit in the jack one way.
2. Turn the plug carefully until it lines up with the jack and then firmly push the plug in place.
Do not apply undue force or try to twist the plug side-to-side.
3. If the vane is not connected to the meter or if the sensor is defective, the
Air Flow Measurements (CMM / CFM)
1.
Turn on the meter using the ON/OFF button
2.
Press the UNITS button to select the desired air flow units: CMM
(cubic meters per minute) or CFM (cubic feet per minute).
NOTE: At power up the meter will display the last unit of
measure previously entered.
3.
To begin entering the area in m2 or ft2, press and hold the AREA
button until it beeps twice. The leftmost digit of the bottom
display
Extech Instruments AN100 Air Flow Averaging Mode
1. To enter 20 Point Averaging Mode, press and hold the AVG button until it beeps twice. The
AVG icon will be displayed.
2. Take a measurement and press the AVG button. A single beep will sound and the HOLD icon
will appear in the display.
3. The average reading will be displayed and number of readings measured will appear in the
upper right hand corner of the display. After 5 seconds, the display will retu
appears on the LCD, the 9V battery must be replaced.
1. Disconnect the sensor.
2. Remove the meter’s rubber protective jacket
3. Use a Phillips screwdriver to open the rear battery compartment
4. Replace the 9V battery
5. Close the battery compartment and replace the meter’s protective jacket
Safety: Please dispose of batteries responsibly and never dispose of batteries in a fire, batteries
may explod
Accuracy (% of reading)
m/s (meters per sec)
0.40 - 30.00 m/s
0.01 m/s
± (3%rdg + 0.20 m/s)
km/h (kilometers/hour)
1.4 - 108.0 km/h
0.1 km/h
± (3%rdg + 0.8 km/hr)
ft/min (feet per minute)
80 – 5900 ft/min
1 ft/min
± (3%rdg + 40 ft/m)
mph (miles per hour)
0.9 – 67.0 mph
0.1 mph
± (3%rdg + 0.4 MPH)
knots (nautical MPH)
0.8 to 58.0 knots
0.1 knots
± (3%rdg + 0.4 knots)
Air Flow
Ra
Extech Instruments AN100 Useful Equations and Conversions
Area equation for rectangular or square ducts
Area equation for circular ducts
Cubic equations
NOTE: Measurements made in inches
must be converted to feet or meters before using the above formulae.
Unit of Measure Conversion Table
m/s
ft/min
knots
km/h
MPH
1 m/s
1
196.87
1.944
3.6
2.24
1 ft/min
0.00508
1
0.00987
0.01829
0.01138
1 knot
0.5144
101.27
1
1.8519
1.1523
1 km/h
0.2778
54.69
0.54
1
0.6222
Extech Instruments Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
461923 |
PDF User Guide (@36R54N), Extech Instruments 461923 Measuring Instruments (16-07-2026) |
3 | 1029 | 165 | 16-07-2026 | |
VB450 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 02-08-2026) |
12 | 602 | 91 | 02-08-2026 | |
CT-3060 |
Measuring Instruments #Q1PM97 |
12 | 542 | 120 | 15-05-2026 | |
AN510 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 27-05-2026) |
8 | 84 | 13 | 27-05-2026 | |
380942 |
User Guide: Extech Instruments 380942 (896M17, Upd.20-09-2026) |
6 | 468 | 75 | 20-09-2026 | |
461891 |
User Guide: Extech Instruments 461891 (7HHC1H, Upd.07-07-2026) |
7 | 1262 | 190 | 07-07-2026 |