CFM/CMM Thermo Anemometer

Model AN100 www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Extech Instruments AN100 Congratulations on your purchase of the Extech AN100 CFM/CMM Thermo Anemometer. This

instrument measures Air Velocity, Air Flow (volume) and Temperature. The large, easy-to-read backlit LCD includes primary and secondary displays plus numerous status indicators. The meter is shipped fully tested and calibrated and with proper use will provide years of reliable service. Descriptions 1. LCD Display 2. Vane Probe 3. Rubb

• AUTO POWER OFF Press to turn the meter ON or OFF

• MAX/MIN (for Airflow/Air Velocity) Used to record and store the highest, lowest and average airflow or velocity readings. ◄ (LEFT) also serves as change decimal point button in AREA mode • UNITS Press to select the mode of operation. In FLOW mode, the meter displays air volume. In VELOCITY mode, the meter displays air speed. ▲(UP) also serves as increase n

MAX (top of LCD): Max Hold function engaged for the Air Temperature function

 HOLD (top of LCD): Data Hold function engaged for the Air Temperature function  VEL: indicates that meter is in air velocity mode  FLOW: indicates that meter is in air flow mode  MAX (bottom of LCD): Max Hold for the IR Temperature and RH function  HOLD (bottom of LCD): Data Hold for the IR Temperature function and RH function

Extech Instruments AN100 Connecting the Vane

1. The vane plug is inserted in the meter’s sensor jack at the top of the meter. The plug and jack are keyed so that the plug can only fit in the jack one way. 2. Turn the plug carefully until it lines up with the jack and then firmly push the plug in place. Do not apply undue force or try to twist the plug side-to-side. 3. If the vane is not connected to the meter or if the sensor is defective, the

Air Flow Measurements (CMM / CFM)

1. Turn on the meter using the ON/OFF button 2. Press the UNITS button to select the desired air flow units: CMM (cubic meters per minute) or CFM (cubic feet per minute). NOTE: At power up the meter will display the last unit of measure previously entered. 3. To begin entering the area in m2 or ft2, press and hold the AREA button until it beeps twice. The leftmost digit of the bottom display

Extech Instruments AN100 Air Flow Averaging Mode

1. To enter 20 Point Averaging Mode, press and hold the AVG button until it beeps twice. The AVG icon will be displayed. 2. Take a measurement and press the AVG button. A single beep will sound and the HOLD icon will appear in the display. 3. The average reading will be displayed and number of readings measured will appear in the upper right hand corner of the display. After 5 seconds, the display will retu

appears on the LCD, the 9V battery must be replaced.

1. Disconnect the sensor. 2. Remove the meter’s rubber protective jacket 3. Use a Phillips screwdriver to open the rear battery compartment 4. Replace the 9V battery 5. Close the battery compartment and replace the meter’s protective jacket Safety: Please dispose of batteries responsibly and never dispose of batteries in a fire, batteries may explod

Accuracy (% of reading)

m/s (meters per sec) 0.40 - 30.00 m/s 0.01 m/s ± (3%rdg + 0.20 m/s) km/h (kilometers/hour) 1.4 - 108.0 km/h 0.1 km/h ± (3%rdg + 0.8 km/hr) ft/min (feet per minute) 80 – 5900 ft/min 1 ft/min ± (3%rdg + 40 ft/m) mph (miles per hour) 0.9 – 67.0 mph 0.1 mph ± (3%rdg + 0.4 MPH) knots (nautical MPH) 0.8 to 58.0 knots 0.1 knots ± (3%rdg + 0.4 knots) Air Flow Ra

Extech Instruments AN100 Useful Equations and Conversions

Area equation for rectangular or square ducts Area equation for circular ducts Cubic equations NOTE: Measurements made in inches must be converted to feet or meters before using the above formulae. Unit of Measure Conversion Table m/s ft/min knots km/h MPH 1 m/s 1 196.87 1.944 3.6 2.24 1 ft/min 0.00508 1 0.00987 0.01829 0.01138 1 knot 0.5144 101.27 1 1.8519 1.1523 1 km/h 0.2778 54.69 0.54 1 0.6222

Extech Instruments Measuring Instruments Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
461923

PDF User Guide (@36R54N), Extech Instruments 461923 Measuring Instruments (16-07-2026)

3 1029 165 16-07-2026
VB450

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 02-08-2026)

12 602 91 02-08-2026
CT-3060

Measuring Instruments #Q1PM97

12 542 120 15-05-2026
AN510

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 27-05-2026)

8 84 13 27-05-2026
380942

User Guide: Extech Instruments 380942 (896M17, Upd.20-09-2026)

6 468 75 20-09-2026
461891

User Guide: Extech Instruments 461891 (7HHC1H, Upd.07-07-2026)

7 1262 190 07-07-2026

Measuring Instruments: Similar Manuals