BFT DEIMOS BT A400 120 Quick Start Manual

Specifications

Brand: BFT
Category: Gate Opener
Model: DEIMOS BT A400 120 (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the BFT DEIMOS BT A400 120 Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Limit switch adjustment

3 4 >25 mm 60-70 mm 17 mm + X I te ≥ 20 mm Concrete foundation 17 mm Y Y + 50 mm Use normalised black cables R02V - HO5VVF Gear set / rack 2 mm DEIMOS BTA FW ≥ 3.03 X = Rack Programming (see reverse) Product reserved for professionals For safety warnings, please see complete instruction manual Position the feet at the limit switches while keeping a 2 cm margin before the gate stop. The limit switch pawl should be all down. Note: the first trigger pulse after switching on power is the opening. D812965 04903_01 18-10-17

How to programme the remote control

6 10 11 M 41 43 42 10 11 M 41 43 42 4 Fine-tune the limit switch adjustment. 5 LED RADIO FLASHES RADIO START x1 S1 S2 S3 S1 S1 OK LED RADIO FLASHES S1 Y Y + 50 mm = AUTO OPEN AUTO CLOSE AUTO OPEN AUTO CLOSE 5s SET SET SET OK KO S1 S2 S3 S1 S2 S3 LED radio Intermittent fashing S1 S2 S3 S1 S2 S3 LED radio Steadily lit LED radio Continuous fashing Y # ANT SHIELD Antenne + + + F3 1,25A T F1 0,63A T (220-230V F1 1,6A T (120V) ERR SET RADIO 24V - 24V + 24 VSafe+ COM START OPEN NO NO Accessories power supply Limit switch connector * Commands PHOT STOP COM FAULT 1 BAR FAULT 2 NC NC NC Safety devices Power supply L N 220-230V ~ * M1 Motor* Blinker + REF SWE SWC SWO 10 L N 11 20 21 41 42 43 50 51 52 60 61 62 70 71 72 73 74 75 24V ! 24V~ 220-230V~* POWER SWO SWC START OPEN STOP PHOT FAULT1 BAR FAULT2 S1 S2 S3 *factory pre-wired 1 2 3 Hamal control board HAMAL 3 By default, the opening is on the right. If the opening is on the left, check wiring: switch 10-11 & 42-43. mini maxi + + + 7 S2 >5s S1+ S2 >10s KEYS Description S1 S2 S3 Add Start Key associates the desired key with the Start command. Add Pedestrian Key associates the desired key with the pedestrian command. Confrms the changes made to parameter settings and operating Erase List WARNING! Erases all memorized transmitters from the receiver’s memory. Pressed BRIEFLY, it gives the START command. HELD DOWN (>5 sec.), it activates the AUTOSET function. 2 TRIMMER Function T1 T2 Waiting time before automatic closing. 0 120 5 50 10 90 % Force exerted by leaf % Slow-down speed T3 + mini. + maxi 3 2 1 ON OFF 1 Apartment building Residential Reaction to the START input (wired or radio): CLOSED Opens Stops Opens Opens Opens OPEN Closes Closes Opens WHILE CLOSING STOPS+TCA No effect WHILE OPENING AFTER STOP Apartment building Residential Reaction to the OPEN input (wired): CLOSED Opens Opens Opens Opens Opens OPEN Opens WHILE CLOSING Keeps it open Keeps it open No effect No effect WHILE OPENING AFTER STOP Closes Closes STOPS+TCA No effect Apartment building Residential Reaction to the PEDESTRIAN input (radio): CLOSED Opens partially Opens partially Opens partially Opens partially Stops Opens partially OPEN WHILE CLOSING WHILE OPENING AFTER STOP How to perform an open/close test by using the remote control. Testing the direction of opening - running / stop: apply power, motor engaged and at stroke centre. Checking the direction of rotation. Start an autoset, gate closed. Fine-tune the adjustments. Motor functions using the potentiometers (T1, T2, T3). Remember to check by pressing S2 for 5 sec. As an option, to go further.... 1 - I wish to deactivate the photocells during opening: 3 - I wish to activate pedestrian opening: Place dipswitch 5 in the ON position. 2 - I wish to activate and adjust automatic closure: This is done by regulating the T1 potentiometer. Please refer to the remote control programming by pressing S2. DIP Function 1 Transmitter programming Selection of sensing bars. Check photocells. Secure entry check. Photocells during closing ON: Memorise the commands OFF : Disables memorizing of transmitters ON : Input for resistive edge 8K2. OFF: Entry for sensitive lintel. ON : Enable safety check OFF: Deactivate the check. ON : Enable safety check OFF: Deactivate the check. ON: Invert the movement during the closure phase only. OFF: Active on opening and closing; invert the movement during the closure phase. 2 3 4 5 Sets the automation type of operation: ON = Apartment building OFF = Residential ON : Safety edge with active reversal only when closing, when opening the movement stops OFF : Safety edge with active reversal in both directions Fast closure. ON : Closes 3 seconds after the photocells are cleared OFF: Fast closure deactivated. 7 Safety edge input operation 6 Residential / apartment building operation 8 *factory pre-parameterised Choose the key Press the 2 top keys simultaneously (hidden key). The LED remains fxed 24V 2 1 TX1 2 1 RX1 4 5 3 50 51 52 70 72 73 DIP3=ON DIP3=OFF Wire the THEA photocells. 1b 1a Wire the DESME photocells 24V 2 1 TX1 2 1 RX1 4 5 3 50 51 70 72 or

Other Gate Opener Manuals