D814123 0AA00_01 13-12-19
I INSTALLATION MANUAL
THALIA
Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie
aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen”tigre aan de binnenkant zorgvuldig!
CONTROL PANEL
F2 3,15 AT
F1 1.25 AT(220-230V)
F1 2.5 AT (120V)
ANT.
ANT
SHIELD
24V
220-230V ~*
S2
S1
S3
0,75
0,75
0,75
0,75
0,75
*
L
N
10 11
L
N
M1
220-230V ~*
14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74
75
+
M2
24V
AUX 3
(MAX 24V 1A)
- REF SWE
+ REF SWE
SWC 1 / SW 1 / ENC1A
SWO 1 / SW 2 / ENC1B
SWC2 / ENC2A
SWO2 / ENC2B
24V -
24V +
24 VSafe+
COM
IC 1
IC 2
COM
SAFE 1
STOP
FAULT 1
SAFE 2
FAULT 2
-
+
-
NO
NO
NC
NC
NC
JP20
3x2,5 mm2
3x2,5 mm2
230V
(*)
24V
(*) 110V
26
AUX 3 ≠ 1
AUX 3 = 1
27
1
26 27
50 51
24 V~
SCA
220
+
+
S1
X1
OPEN
S1
X1
STOP
-
-
S2
X1
CLOSE
S2
X1
STOP
OPEN
CLOSE
QUICK INSTALLATION
See motor specifications
ELI encoder activation
Other voltages available on request
Optional board connector
Palmtop programmer connector, Connecter
Display plus programming keys,
Power supply
Motor
Accessories power supply
Encoder/limit switch inputs
AUX
Safety devices
Commands
Antenna
TUBE ARRANGEMENT
2 - THALIA
D814123 0AA00_01
IT IS NECESSARY TO FOLLOW THIS SEQUENCE OF ADJUSTMENTS:
1 - Adjusting the limit switches
2 - Autoset
3 - Programming remote controls
4 - Setting of parameters/logic, where necessary
After each adjustment of the end stop position a new autoset is required.
After each modification of the motor type, a new autoset must be carried out
If the simplified menu is used:
- In GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A 50 - E5 BT A18 - E5 BT A12 motors: phase
1 (end stop adjustment) is included in the simplified menu.
- In other motors: phase 1 (end stop adjustment) must be carried out before activating
the simplified menu
D2
D1
72
50 51
70
24V ~
2
1
TX1
2
1
RX1
4
5
3
SAFE 1 = 0
SAFE 1 = 1
72
50 51
70
24V ~
Vsafe
73
52
2
1
TX1
2
1
RX1
4
5
3
Photocells not checked (Check every 6 months)
Photocell checked
THALIA - 3
D814123 0AA00_01
ELI 250 BT
2
E
40 41 42 43 44 45
+ REF SWE
SWC 1
SWO 1
SWC2
SWO2
10 11
M1
14 15
+
M2
-
+
-
PHOBOS N BT tipo otore - type de oteur - otorentyp - otor type - tipo otor:
1
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M1
M2
M2
M1
M2
M2
M1
M1
40 41 42 43 44 45
SW 1
10 11
M1
14 15
M2
+
-
+
-
SW 2
3
IGEA BT tipo otore - type de oteur - otorentyp - otor type - tipo otor:
40 41 42 43 44 45
SW 1
10 11
M1
14 15
+
M2
-
+
-
SW 2
M2
M1
1 2 3
SW 1
M1 +
M1-
1 2 3
SW 2
M2 +
M2-
M2
M1
1 2 3
SW 1
M1 +
M1-
1 2 3
SW 2
M2 +
M2-
M1
M2
M2
M1
M2
M2
M1
M1
M1
M1
M2
M2
= 1 (ext)
open in other direct.
= 1 (ext)
open in other direct.
i
= 1 (ext)
open in other direct.
= 0 (int)
iopen in other direct.
= 0 (int)
open in other direct.
= 0 (int)
open in other direct.
ELI 250 BT
Maximum power
180W
Maximum cycle-
continuous cycle
PHOBOS N BT
Maximum power n
40W
Cycle maximum
S3 13s-1-13s-1 x30
pause
IGEA BT
Maximum power
70W
Maximum cycle
continuous cycle
change mot
= 0
change mot = 0
change mot
= 0
change mot = 0
change mot
= 0
change mot
= 0
4 - THALIA
D814123 0AA00_01
tipo motore - type de moteur - motorentyp - motor type - tipo motor:
tipo motore - type de moteur - motorentyp - motor type - tipo motor: 4
6
E
40 41 42 43 44 45
SW 1
SW 2
10 11
M1
14 15
-
M2
+
+
-
M1
M1
M2
M2
M2
M2
M1
M1
7
PHOBOS BT A / KUSTOS BT A tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M1
M2
M2
M1
M2
M2
M1
M1
40 41 42 43 44 45
SW 1
10 11
M1
14 15
M2
+
-
+
-
SW 2
M2
M1
1 2 3
SW 1
M1 +
M1-
1 2 3
SW 2
M2 +
M2-
White
Red
**Rosso
*Bianco
*Bianco
***Nero
***Nero
**Rosso
Black
SUB BT
Maximum power
90W
Maximum cycle
S3 17s-1-17s-1 x21
pause 90 min.
LEAF MAX
400 kg
2 m
TYPE OF USE - SEMI-INTENSIVE
Semi-intensive
= 0 (int)
open in other direct.
change mot
= 0
= 1 (ext)
open in other direct.
change mot
= 0
PHOBOS BT A
KUSTOS BT A
Maximum power -
40W
40W
Maximum cycle
S3 13s-1-13s-1 x30
pause
90min.
S3 13s-1-13s-1 x30
pause
90min.
= 1 (ext)
open in other direct.
= 0 (int)
open in other direct.
change mot
= 0
change mot
= 0
NON-MANAGED MOTORS
THALIA - 5
D814123 0AA00_01
tipo motore - type de moteur - motorentyp - motor type - tipo motor: 8
1
2
3
4
M1 +
M1 -
- REF SWE
SW 1
1
2
3
4
M2 +
M2 -
- REF SWE
SW 2
reg. fc. - l.sg adj - regl.fc - endsche inst
M1
M1
M2
M1
M2
M2
M2
M1
M1
M2
40 41 42 43 44 45
10 11
M1
14 15
M2
+
-
+
-
SW 1
- REF SWE
SW 2
1
2
GIUNO ULTRA BT A 20
GIUNO ULTRA BT A 50
Maximum power
90W
90W
Maximum cycle
S3 10s-5-14s-5 x40
pausa -pause - pause pause -
pausa - pauze 90 min.
S3 10s-5-14s-5 x40
pausa -pause - pause pause - pausa -
pauze 90 min.
LEAF MAX.
150 kg
150 - 400 kg
2 m
5 - 2 m
TYPE OF USE - SEMI-INTENSIVE
Semi-intensive
= 1 (ext)
open in other direct.
= 0 (int)
open in other direct.
change mot
= 0
change mot
= 0
ATTENTION: with actuators with integrated locks, the permanently active slowdown to a value higher than 5 is mandatory.
6 - THALIA
D814123 0AA00_01
40 41 42 43 44 45
SW 1
10 11
M1
14 15
M2
-
+
+
-
10
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
SW 2
9
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
40 41 42 43 44 45
+ REF SWE
SWC 1 *
SWO 1 *
SWC2 *
SWO2 *
blu***
rosso****
blu***
rosso****
10 11
M1
14 15
-
M2
+
-
+
M1
M2
M1
M2
M1
M2
M1
M2
M2
M1
M2
M1
M2
M1
M2
M1
M2
M1
1 2 3
SW 1
M1 -
M1+
1 2 3
SW 2
M2 -
M2+
inv.mot / change mot / inv.mot = 0
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 0
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 0
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 0
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 1
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 1
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 1
mot.tausch / inv.mot / inv.mot
inv.mot / change mot / inv.mot = 1
mot.tausch / inv.mot / inv.mot
SWC * / SWO **
SWO* / SWC**
VIRGO SMART BT A ( 3 wires )
VIRGO SMART BT A (5 wires)
= 0 (int)
open in other direct.
= 1 (ext)
open in other direct.
= 1 (ext)
open in other direct. :
= 0 (int)
open in other direct.
1= +Red ****
2= - Blu ***
3= SWO*/SWC**
4= SWC*/SWO**
5= +REF SWE
VIRGO SMART BT A
Maximum power
110W
Maximum cycle 20 cycles/h
* With reverse logic, opening direction = 000 (DIR=INT)
** With reverse logic, opening direction = 001 (DIR=ext)
*** Blu
**** Red
M1= VIRGO SMART BT A (Left) / M2= VIRGO SMART BT A SQ (Right)
M1= VIRGO SMART BT A (Right) / M2= VIRGO SMART BT A SQ (Left)
ATTENTION: with actuators with integrated locks, the permanently active slowdown to a value higher than 5 is mandatory.
THALIA - 7
D814123 0AA00_01
E5 BT A18
E
40 41 42 43 44 45
- REF SWE
SW 1
10 11
M1
14 15
+
M2
-
+
-
SW 2
11
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
E5 BT A12
12
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M2
M2
M1
M1
M1
M1
M2
M2
60
COM
1
2
3
4
M1 +
M1 -
COM
- REF SWE
SW 1
M1
5
1
2
3
4
M2 +
M2 -
COM
- REF SWE
SW 2
M2
5
E5 BT A18
E5 BT A12
Maximum power 40W
40W
Maximum cycle 20 cycles/h
100 cycles/h
LEAF MAX see the motor’s manual
see the table below
Maximum cable length
30m
30m
= 1 (ext)
open in other direct.
= 0 (int)
open in other direct.
change mot
= 0
change mot
= 0
E5 BT A12
ON pedestrian gates, adjust the speed so as to limit the energy of the leaf within a
maximum value of 1.69 Joule (as required by the EN16005 regulation).
Use the table to determine the minimum closing times between 90°and 10°.
Table with the leaf manoeuvre minimum times
Leaf width (mm)
)
Leaf weight (kg)
50
60
70
80
90
750 mm
3,0 s
3,0 s
3,0 s
3,0 s
3,5 s
850 mm
3,0 s
3,0 s
3,5 s
3,5 s
4,0 s
1000 mm
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
1200 mm
4,0 s
4,5 s
4,5 s
5,0 s
5,5 s
The approaching phase (from 10° to the limit switch position) must take place in at least 1.5 s.
Example: if the leaf weighs 80 kg and has a width of 1000 mm, adjust the manoeuvre speed from 90° and 10° in at least 4.0 s.
For intermediate values, use the higher value: if the leaf weighs 75 kg consider a value of 80 kg, if its width is 1100 mm use a value of 1200 mm.
IMPORTANT: Low-energy operation is not considered a proper safety measure if the leaf is used by elderly, invalid, disabled people and children.
In this case, provide additional safety measures, according to the provisions of the legislation in force.
Select the correct
motor model
8 - THALIA
D814123 0AA00_01
ELI BT A 40 LS
E
40 41 42 43 44 45
+ REF SWE
SWC 1
SWO 1
SWC2
SWO2
10 11
M1
14 15
+
M2
-
+
-
13
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M2
M2
M1
M1
M1
M1
M2
M2
ELI BT A35 LS
40 41 42 43 44 45
+ REF SWE
SWC 1
SWO 1
SWC2
SWO2
10 11
M1
14 15
+
M2
-
+
-
14
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M2
M2
M1
M1
M1
M1
M2
M2
ELI BT A40
40 41 42 43 44 45
- REF white *
+ REF brown**
ENC M1 green ***
ENC M2 green ***
10 11
M1
14 15
+
M2
-
+
-
15
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M2
M2
M1
M1
M1
M1
M2
M2
= 1 (ext)
open in other direct.
= 1 (ext)
open in other direct.
= 1 (ext)
open in other direct.
= 0 (int)
open in other direct.
= 0 (int)
open in other direct.
= 0 (int)
open in other direct.
ELI BT A 40 LS
Maximum power
180W
Maximum cycle
continuous cycle
change mot
= 0
change mot
= 0
change mot
= 0
change mot
= 0
change mot
= 0
change mot
= 0
with limit stop
ELI BT A 35 LS
Maximum power
40W
Maximum cycle
40 cycles/h
ELI BT A 40
Maximum power
180W
Maximum cycle
continuous cycle
*White
**Brown
***Green
with limit stop
THALIA - 9
D814123 0AA00_01
ELI BT A35
16
tipo otore - type de oteur - otorentyp - otor type - tipo otor:
M2
M2
M1
M1
M1
M1
M2
M2
40 41 42 43 44 45
- REF white *
+ REF brown**
ENC M1 green ***
ENC M2 green ***
10 11
M1
14 15
+
M2
-
+
-
E
= 1 (ext)
iopen in other direct.
= 0 (int)
open in other direct.
ELI BT A35
Maximum power
40W
Maximum cycle
40 cycles/h
change mot
= 0
change mot
= 0
*White
**Brown
***Green
10 - THALIA
D814123 0AA00_01
MIN 1 - MAX 3
AUTO OPEN
AUTO CLOSE
autoset
O 01
. . . . . .
o
o
end
desidered button
hidden button
release
mem.remotes
preset
Dir
int
ext
lang
.....
x1
eli
phobos bt a
phobos n
2
1
ar
Sr
Ac
Sc
ind
ita
fra
deu
eng
esp
n. mot.
type
0---
10--
OK
150-
OK
1520
OK
OK
/
P1
P2
P1
P2
P1
P2
P1
P2
/
end
ersu
o
o
l.sw adj
l.sw adj
GIUNO ULTRA
opm1
opm2
clm2
clm1
E5 A18 / E5 A12
1
2
1
1
2
2
1
2
1
2
1
2
manual movement
ELI BT
KUSTOS BT A
PHOBOS BT A
PHOBOS N BT
IGEA BT
SUB BT
VIRGO SMART BT A
ELI BT A40 LS
ELI BT A35 LS
ELI BT A40
ELI BT A35
PRESET
DEFAULT
ar
sr
ac
sc
ind
PARAMETERS
LOGIC
TCA
0
1
0
1
0
0
Step-by-step movement
0
1
0
1
0
0
Pre-alarm
0
0
0
1
1
0
Deadman
0
0
0
0
0
1
Block pulses during opening
0
0
0
1
1
0
SIMPLIFIED MENU
: motor 1 opening
limit switch adjustment
: motor 1/2
opening
limit switch
adjustment
: motor 1/2
closing
limit switch
adjustment
Refer to the
settings on the
adjustment of
the limit switches
found in the
GIUNO ULTRA
motor manual.
or
or
or
or
or
or
or
or
: motor 2 opening
limit switch adjustment
: motor 2 closing
limit switch adjustment
: motor 1 closing
limit switch adjustment
INT: inward opening
EXT: outward opening
ar: automatic operation, residential
sr: semiautomatic operation, residential
ac: automatic operation, commercial
Sc: semiautomatic operation, commercial
Ind: dead man operation
LEGENDA
Scroll up
Scroll own
Confirm/
Switch
on display
Exit menù
Password entry. Request with Protection Level logic set to 1, 2, 3, 4
12 - THALIA
D814123 0AA00_01
50 51 52
70 71 72 73 74 75
24V -
24V +
24 VSafe+
COM
SAFE 1
SAFE 2
STOP
FAULT 1
FAULT 2
NC
NC
NC
1-S
2-S
3-S
4-S
5-S
6-S
(SCS-MA)
SAFE 1
1
2
1
2
3
4
5
51
TX1
RX1
1 Bar 1
2
3
4
5
6
1
2
1
2
3
4
5
52
50
TX1
RX1
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX4
RX4
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 4
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
6
6
6
6
6
6
6
6
6
6
1
2
1
2
3
4
5
TX1
RX1
1 Bar 1
2
3
4
5
6
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX4
RX4
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 4
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
6
6
6
6
6
6
6
6
6
6
SAFE1 = 1,3,5
SAFE1 = 0,2,4
SAFE1 = 7,10,13
1 PHOT / 1 PHOT OP / 1 PHOT CL
1 PHOT / 1 PHOT OP / 1 PHOT CL
2 PHOT / 2 PHOT OP / 2 PHOT CL
3 PHOT / 3 PHOT OP / 3 PHOT CL
4 PHOT / 4 PHOT OP / 4 PHOT CL
BAR 8K2/BAR 8k2 OP/BAR 8k2 CL
1 BAR / 1 BAR OP / 1 BAR CL
1 BAR / 1 BAR OP / 1 BAR CL
2 BAR / 2 BAR OP / 2 BAR CL
3 BAR / 3 BAR OP / 3 BAR CL
4 BAR / 4 BAR OP / 4 BAR CL
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
70
72
70
72
73
70
70
70
70
70
70
72
72
72
73
2-S
1-S
3-S
73
2-S
1-S
3-S
5-S
4-S
6-S
73
51
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
52
52
52
52
52
52
52
52
52
52
72
70
72
70
73
72
70
51
50
70
73
72
70
4-S
5-S
6-S
70
73
72
70
1-S
2-S
4-S
5-S
3-S
70
73
6-S
70
72
8,2Kohm 5%
SAFETY EDGE
SAFETY EDGE
1
SAFE1 = 6,9,12
3
2
5
4
SAFE 2
1
2
1
2
3
4
5
51
TX1
RX1
1 Bar 1
2
3
4
5
6
1
2
1
2
3
4
5
52
50
TX1
RX1
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX4
RX4
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 4
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
6
6
6
6
6
6
6
6
6
6
1
2
1
2
3
4
5
TX1
RX1
1 Bar 1
2
3
4
5
6
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX1
RX1
1
2
1
2
3
4
5
TX2
RX2
1
2
1
2
3
4
5
TX3
RX3
1
2
1
2
3
4
5
TX4
RX4
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
1 Bar 2
2
3
4
5
1 Bar 4
2
3
4
5
1 Bar 3
2
3
4
5
1 Bar 1
2
3
4
5
6
6
6
6
6
6
6
6
6
6
SAFe 2= 1,3,5
SAFe 2 = 0,2,4
SAFe 2 = 6,9,12
SAFe 2 = 7,10,13
SAFe 2 = 8,11,14
SAFe 1 = 8,11,14
1 PHOT / 1 PHOT OP / 1 PHOT CL
1 PHOT / 1 PHOT OP / 1 PHOT CL
2 PHOT / 2 PHOT OP / 2 PHOT CL
3 PHOT / 3 PHOT OP / 3 PHOT CL
4 PHOT / 4 PHOT OP / 4 PHOT CL
BAR 8K2/BAR 8k2 OP/BAR 8k2 CL
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
52
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
70
74
70
74
75
70
70
70
70
70
70
74
74
74
75
2-S
1-S
3-S
75
2-S
1-S
3-S
5-S
4-S
6-S
75
51
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
51
50
52
52
52
52
52
52
52
52
52
52
74
70
74
70
75
74
70
51
50
70
75
74
70
4-S
5-S
6-S
70
75
74
70
1-S
2-S
4-S
5-S
3-S
70
75
6-S
70
74
8,2Kohm 5%
SAFETY EDGE
SAFETY EDGE
1
3
2
4
5
TEST OFF
TEST ON
TEST OFF
TEST ON
1 BAR / 1 BAR OP / 1 BAR CL
1 BAR / 1 BAR OP / 1 BAR CL
2 BAR / 2 BAR OP / 2 BAR CL
3 BAR / 3 BAR OP / 3 BAR CL
4 BAR / 4 BAR OP / 4 BAR CL
Numero massimo di dispositivi verifcati: 6 (ma non più di 4 per tipo),
Maximum number of tested devices: 6 (but no more than 4 per type),
Nombre maximum dispositif vérifés: 6 (mais pas plus de 4 par type),
Max. Anzahl der überprüften Geräte: 6 (jedoch nicht mehr als 4 je Typ),
Número máximo dispositivos comprobados: 6 (pero no más de 4 por tipo),
Maximumaantal “trusted devices”: 6 (maar niet meer dan 4 per type)
THALIA - 17
D814123 0AA00_01
ECB 24 V~
UNIDA
THALIA
A
B
C
D
OPEN
OPEN
S1
S2
S3
+
-
OK
S1
S2
S3
+
-
OK
70
71
COM
STOP
S1
S2
S3
+
-
OK
S1
S2
S3
+
-
OK
8888
rst8
8888
.
...
J
1
2
3
4
6
5
!
<3s
+
ON
OFF
(versione x.40 e successive)
(x.40 and later versions)
(version x.40 et suivantes)
(Version x.40 und nachfolgende)
(versión x.40 y sucesivas )
(versie x.40 en hoger)
Programmatore palmare universale
Universal palmtop programmer
Programmateur palmaire universel
Universal-Handprogrammiergerät
Programador portátil universal
Universele programmeerbare palmtop
Scheda di espansione
Expansion board
Carte d’expansion
Erweiterungskarte
Tarjeta de expansión
Uitbreidingskaart
18 - THALIA
D814123 0AA00_01
. . .
pRg
OK
OK
pRg
OK
P1
P2
P1
P2
P1
P2
P1
P2
//
/
/
/
/
logic.
logic.
2
radio
OK
add. start
hidden butt
desired button
release
OK
/
01
Add. 2ch
hidden butt
desired button
release
OK
01
prg.
OK
erase 64
ia9c
OK
22fd
OK
01
OK
OK
cod rh
OK
u
off
/
default
OK
pRg
/
language
OK
OK
OK
OK
OK
OK
ita
fra
deu
eng
esp
/
/
/
autoset
OK
. . . . . .
/
/
l.sw adj
OK
/
OK
/
1
2
op 1
OK
op 2
OK
cl 2
OK
cl 1
ersu
1
2
1
2
1
2
1
2
1
2
E5 A18 - E5 A12
GIUNO ULTRA
manual mouvement
Password entry. Request with Protection Level logic set to 1, 2, 3, 4
Scroll up
Scroll down
Exit Menù
Confirm/Switch on
display
LEGENDA
SEE PARAMETERS MENU
SEE LOGIC MENU
SEE RADIO MENU
or
or
or
or
or
or
or
or
ACCESS MENUS FIG. 1
THALIA - 29
D814123 0AA00_01
bft. . .
/
/
Err
OK
01.33
02.01
. . . . .
30.15
OK
0---
10--
OK
150-
OK
1520
prg
OK
OK
P1
P2
P1
P2
P1
P2
P1
P2
OK
0000
/
OK
0000
/
n. cycles
n. re otes
Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT
Activation of PHOT photocell input or, if configured as verified photocell, Activation
of the associated FAULT input
PHOP
Activation of PHOT OP opening photocell input or, if configured as active verified
photocell only when opening, Activation of the associated FAULT input
PHCL
Activation of PHOT CL closing photocell input or, if configured as active verified
photocell only when closing, Activation of the associated FAULT input
BAR
Activation of BAR safety edge input or, if configured as verified safety edge, Acti-
vation of the associated FAULT input
baro
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE OPENING,
or, if configured as verified safety edge active only while opening, Activation of
the associated FAULT input
barc
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE CLOSING,
or, if configured as verified safety edge active only while closing, Activation of the
associated FAULT input
SET
The board is standing by to perform a complete opening-closing cycle uninter-
rupted by intermediate stops in order to acquire the torque required for movement.
WARNING! Obstacle detection not active
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or parameter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or parameter/logic setting
er06
8k2 safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER07
Opening safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER08
Closing safety edge test failed
Check safety edge connection and/or parameter/logic settings
ER1x*
Board hardware test error
- Check connections to motor
- Hardware problems with board (contact technical assistance)
ER2x*
Encoder error
- Motor or encoder signal power cables inverted/disconnected or incorrect pro-
gramming (see Fig. E)
- Actuator movement is too slow or stopped with respect to programmed operation.
ER3x*
Reverse due to obstacle - Amperostop
Check fo r obstacles in path
ER4x*
Thermal cutout
Allow automated device to cool
ER5x*
Communication error with remote devices
Check connection with serial-connected accessory devices and/or expansion boards
ER70, ER71
ER74, ER75
Internal system supervision control error.
Try switching the board off and back on again. If the problem persists, contact the
technical assistance department.
ER72
Consistency error of the control unit’s parameters (Logics and Parameters)
Pressing OK the detected settings are confirmed. The board will keep on working
with the detected settings.
The board settings must be checked (Parameters and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
Ersw
Error during limit switch adjustment
Only for E5 BT A18 / E5 BT A12
Motor or encoder signal power cables inverted/disconnected or incorrect
programming. (see Fig. E)
ERf3
Error in the configuration of the logics (SAFE inputs, motor type)
Check that the SAFE logic or motor type configuration is correct.
*X= 0, 1, .., 9, A, B, C, D, E, F
Instantaneous force motor 2
Instantaneous force motor 1
35.40
C= SWC2 motor 2 closing limit
switch input activated
O= SWO1 motor 1 opening limit
switch input activated
C= SWC1 motor 1 closing limit
switch input activated
O= SWO2 motor 2 opening limit
switch input activated
Control unit software version
No total manoeuvres (in hundreds)
No radio control devices memorised
List of last 30 errors
ACCESS MENUS FIG. 1
30 - THALIA
D814123 0AA00_01
2) GENERAL INFORMATION
The THALIA control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
- Electronic torque control with obstacle detection
- Limit switch control inputs based on motor selected
-
Separate inputs for safety devices
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74. If the above-mentioned
terminals are being used, remove the relevant jumpers.
TESTING
The THALIA panel controls (checks) the start relays and safety devices (photocells)
before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
220-230V 50/60 Hz*
Low voltage/mains insulation
> 2MOhm 500V
Operating temperature range
-20 / +55°C
Thermal overload protection
Software
Dielectric rigidity
mains/LV 3750V~ for 1 minute
Motor output current
max. 7.5A+7.5A
Motor relay switching current
10A
Maximum motor power
180W + 180W (24V
)
Accessories power supply
24V~ (demand max. 1A)
24V~safe
AUX 0
NO 24V
powered contact (max.1A)
AUX 3
NO contact (24V~/max.1A)
Fuses
see Fig. C
N° of combinations
4 billion
Max.n° of transmitters that can be memorized
63
(*other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore cable
with a cross-sectional area of at least 3x1.5mm2 of the kind provided for
by the regulations in force. To connect the motors, use a cable with a cross-
sectional area of at least 1.5mm2 of the kind provided for by the regulations
in force. The cable must be type H05RN-F at least.
Terminal
Definition
Description
Power supply
L
LINE
Single-phase power supply 220-230V 50/60 Hz*
N
NEUTRAL
JP5
TRANSF PRIM
Transformer primary winding connection, 220-230V.
JP7
JP21
TRANSF SEC
Board power supply:
24V~ Transformer secondary winding
24V= Buffer battery power supply
Motor
10
MOT1 +
Connection motor 1. Time lag during closing.
Check connections shown in Fig.E
11
MOT1 -
14
MOT2 +
Connection motor 2. Time lag during opening.
Check connections shown in Fig.E
15
MOT2 -
Aux
20
AUX 0 - 24V
POWERED
CONTACT (N.O.)
(MAX. 1A)
AUX 0 configurable output - Default setting FLASHING LIGHT.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE
OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE. Refer to “AUX output configuration” table.
21
26
AUX 3 - FREE
CONTACT
(N.O.)
(Max. 24V 1A)
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE
OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK.
Refer to “AUX output configuration” table.
27
Limit switch for
ELI 250 BT
VIRGO SMART BT A
ELI BT A35 LS
ELI BT A40 LS
5 wires
41
+ REF SWE
Limit switch common
42
SWC 1
Motor 1 closing limit switch SWC1 (N.C.).
43
SWO 1
Motor 1 opening limit switch SWO1 (N.C.).
44
SWC 2
Motor 2 closing limit switch SWC2 (N.C.).
45
SWO 2
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch for
PHOBOS N BT
IGEA BT
SUB BT
PHOBOS BT A
KUSTOS BT A VIRGO
SMART BT A
3 wires
42
SW 1
Limit switch control motor 1.
For actuators with single-wire limit switch control.
43
SW 2
Limit switch control motor 2.
For actuators with single-wire limit switch control.
Limit switch for
GIUNO ULTRA BT A20
GIUNO ULTRA BT A50
E5 BT A18
E5 BT A12
40
- REF SWE
Limit switch common
42
SW 1
Limit switch control motor 1.
43
SW 2
Limit switch control motor 2.
Limit switch for
ELI BT A35 LS
ELI BT A40 LS
40
- REF SWE
Encoder power supply, white cable
41
+ REF SWE
Encoder power supply, brown cable
42
ENC M1
Engine 1 encoder signal, green cable
Close the jumper JP28
43
ENC M2
Engine 2 encoder signal, green cable
Close the jumper JP29
Accessories
power supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
THALIA - 31
D814123 0AA00_01
IC 1 and IC 2 inputs common
61
IC 1
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
62
IC 2
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Safety devices
70
Common
STOP, SAFE 1 and SAFE 2 inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
SAFE 1
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP
TEST / BAR 8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL
Refer to the “Safety input configuration” table.
73
FAULT 1
Test input for safety devices connected to SAFE 1.
74
SAFE 2
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP TEST
/ BAR 8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL
Refer to the “Safety input configuration” table.
75
FAULT 2
Test input for safety devices connected to SAFE 2.
Antenna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the
antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable
position.
#
SHIELD
AUX output configuration
Aux logic= 0 - 2ND RADIO CHANNEL output.
Contact stays closed for 1s when 2nd radio channel is activated.
Aux logic= 1 - SCA GATE OPEN LIGHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIGHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIGHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - GATE OPEN ALARM output.
Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHING LIGHT output.
Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output.
Contact stays closed for 2 seconds each time gate is opened.
Aux logic= 8 - MAGNETIC LOCK output.
Contact stays closed while gate is closed.
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required.
Aux logic= 10 - FLASHING LIGHT AND MAINTENANCE output.
Contact stays closed while leaves are operating. If the value set for the Maintenance parameter is reached, once the gate has finished moving and the leaf is closed, the contact closes
for 10 sec. and opens for 5 sec. 4 times to report that maintenance is required.
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP MOV. logic. External start for traffic light control.
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP MOV. logic. Internal start for traffic light control.
IC logic= 2 - Input configured as Open.
The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time,
where activated.
IC logic= 3 - Input configured as Closed.
The command causes the leaves to close.
IC logic= 4 - Input configured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP. logic
IC logic= 5 - Input configured as Timer.
Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input configured as Timer Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E,
Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input configuration
SAFE logic= 0 - Input configured as Phot (photocell) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken
during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input configured as Phot test (tested photocell). (fig.F, ref.2).
Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is
reversed only once the photocell is cleared.
SAFE logic= 2 - Input configured as Phot op (photocell active during opening only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops
motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input configured as Phot op test (tested photocell active during opening only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken.
SAFE logic= 4 - Input configured as Phot cl (photocell active during closing only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing,
movement is reversed immediately. If not used, leave jumper inserted.
SAFE logic= 5 - Input configured as Phot cl test (tested photocell active during closing only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*). (fig.F, ref.3).
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge (fig.F, ref.4).
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2 (fig.F, ref.5). Input for resistive edge 8K2.
The command reverses movement for 2 sec.
32 - THALIA
D814123 0AA00_01
6) MOTOR WIRING Fig. E
7) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
7.1) TESTED DEVICES Fig. F
7.2) CONNECTION OF 1 PAIR OF NON-CHECKED PHOTOCELLS FIG. D1
7.3) CONNECTION OF 1 PAIR OF CHECKED PHOTOCELLS FIG. D2
8) CALLING UP MENUS: FIG. 1
8.1) PARAMETERS MENU (PARA ) (PARAMETERS TABLE “A”)
8.2) LOGIC MENU (LOGIC) (LOGIC TABLE “B”)
8.3) RADIO MENU (radio) (RADIO TABLE “C”)
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
•
Cloning of master transmitter (rolling code or fixed code).
•
Cloning to replace transmitters already entered in receiver.
•
Transmitter database management.
•
Receiver community management.
To use these advanced features, refer to the universal handheld programmer’s
instructions and to the general receiver programming guide.
8.4) DEFAULT MENU (default)
Restores the controller’s DEFAULT factory settings. Following this reset, you will
need to run the AUTOSET function again.
8.5) LANGUAGE MENU (language)
Used to set the programmer’s language on the display.
8.6) AUTOSET MENU (AUTOset)
• Launch an autoset operation by going to the relevant menu.
• As soon as you press the OK button, the “.... .... ....” message is displayed and the control
unit commands the device to perform a full cycle (opening followed by closing), during
which the minimum torque value required to move the leaf is set automatically.
The number of cycles required for the autoset function can range from 1 to 3.
During this stage, it is important to avoid breaking the photocells’ beams and not
to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the
optimum torque values. Check them and, where necessary, edit them as described
in the programming section.
WARNING!! Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Impact forces can be reduced by using deformable edges.
Warning!! While the autoset function is running, the obstacle detection
function is not active. Consequently, the installer must monitor the
automated system’s movements and keep people and property out
of range of the automated system.
8.7)INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
2. Check the impact forces: if they fall within the limits (**) skip to point 10 of the
procedure, otherwise
3. Where necessary, adjust the speed and sensitivity (force) parameters: see
parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 10
of the procedure, otherwise
5. Apply a shock absorber profile
6. Check the impact forces again: if they fall within the limits (**) skip to point 10
of the procedure, otherwise
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
safety edge) (**)
8. Check the impact forces again: if they fall within the limits (**) skip to point 10
of the procedure, otherwise
9. Allow the drive to move only in “Deadman” mode
10. Make sure all devices designed to detect obstacles within the system’s operating
range are working properly
(*) Before running the autoset function, make sure you have performed all the
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive’s manual.
(**) Based on the risk analysis, you may find it necessary to apply sensitive
protective devices anyway
8.8) LIMIT STOP ADJUSTMENT MENU (REG. FC)
Used to adjust the limit stops for motors equipped with encoder; moreover,
for motors equipped with independent limit stop wiring harness allows the
correct positioning of the leaf for the subsequent limit stop adjustment. For
motors not specified, the menu is not active and the message” unavailable” is
shown on the display
NOTE: these manoeuvres are performed in person preset mode, at slow speed,
without the intervention of the safety devices.
8.8.1) GIUNO ULTRA BT A20, GIUNO ULTRA BT A50
Using the „+/-” buttons on the display, bring the leaf in the desired position. To
adjust the limit stops, refer to the settings for limit stop adjustment provided in
the GIUNO ULTRA motor manual.
8.8.2) E5 BT A12, E5 BT A18
Using the „+/-” buttons on the display, bring the leaf in the position indicated
by the display (opening or closing). Once the desired position is reached,
confirm the position by pressing the OK button. For E5 motors, the leaf can be
manually positioned close to the limit stops by pushing the gate; then move
the gate using the „+/-” button until it is against the mechanical stopper. To
confirm the position, or use the OK button or the radio control (previously
stored).
9) CLOSING LIMIT SWITCH PRESSURE Fig. G Ref. A-B
OPENING DIRECTION Fig. E
10) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. H) Refer to specific manual.
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an
appropriate antenna tuned to 433MHxz.
12) SOLENOID LOCK Fig. I
SOLENOID LOCK
WARNING: In the case of leaves longer than 3m, it is essential to install
a solenoid lock.
Fig. I shows a sample connection of an ECB 24V~ solenoid latch connected to
the THALIA control panel.
In order to control the solenoid lock, the THALIA panel needs a special board
mod. ME BT.
13) RESTORING FACTORY SETTINGS (Fig.J)
WARNING: this operation will restore the control unit’s factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.J ref.1)
- Open the Stop input and press the - and OK keys together (Fig.J ref.2)
- Switch on the board’s power (Fig.J ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.J ref.4)
- Wait for the procedure to finish (Fig.J ref.5)
- Procedure finished (Fig.J ref.6)
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Impact forces can be reduced by using deformable edges.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Safety input configuration
SAFE logic=9 Input configured as Bar op, safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the
automation to stop. If not used, leave jumper inserted.
SAFE logic=10 Input configured as Bar op test, safety edge checked with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 4).
Activates testing safety edges when starting operation. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=11 Input configured as Bar 8k2 op, 8k2 safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) (Fig. F, ref. 5).
The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=12 Input configured as Bar cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening
causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=13 Input configured as Bar cl test, safety edge checked with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 4).
Activates testing safety edges when starting operation. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
SAFE logic=14 Input configured as Bar 8k2 cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) (Fig. F, ref. 5).
The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
THALIA - 33
D814123 0AA00_01
TABLE “A” - PARAMETERS MENU - (PARA )
Parameter
min.
max.
Default
Personal
Definition
Description
OPEN DELAY
TI E
0
10
3
Motor 2 opening delay
time [s]
Motor 2 opening delay time with respect to motor 1.
CLS DELAY
TI E
0
25
6
Motor 1 closing delay
time [s]
Motor 1 closing delay time with respect to motor 2.
NOTE: if the time is set to maximum, before starting, engine 1 waits for the complete
shut down of engine 2.
TCA
0
120
10
Automatic closing time [s]
Waiting time before automatic closing.
TRF.LGHT.
CLR.T
1
180
40
Time-to-clear traffic light
zone [s]
Time-to-clear for the zone run through by traffic controlled by the traffic light.
OP.DIST.
SLOUD
0
50
10
Slow-down distance during
opening [%]
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown
to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 10% will be considered to be 10%.
CL.DIST.
SLOUD
0
50
10
Slow-down distance during
closing [%]
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown
to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 10% will be considered to be 10%.
DIST.DECEL
0
50
15
Deceleration distance [%]
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both
during opening and during closing, given as a percentage of total travel. WARNING: Once the
parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
PARTIAL
OPENING
10
99
99
Partial opening M1 [%]
Partial opening distance as a percentage of total opening following activation of PED
pedestrian command.
OP.FORCE
1
99
50
Leaf force during
opening [%]
Force exerted by leaf/leaves during opening. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary (**).
CLS.FORCE
1
99
50
Leaf force during
closing [%]
Force exerted by leaf/leaves during closing. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary (**).
OP SPEED
15
99
99
Opening speed [%}
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET", obstacle
detection is not active.
CL SPEED
15
99
99
Closing speed [%]
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING:
Once the parameter has been edited, a complete uninterrupted opening-closing cycle
is required. WARNING: when the display reads "SET", obstacle detection is not active.
SLOW SPEED
15
99
25
Slow-down speed [%]
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of
maximum running speed. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: When the display reads
“”SET””, obstacle detection is not active.
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 50% will be considered to be 50%.
ainte-
nance
0
250
0
Programming number of
operations for maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance will
be reported on the AUX output configured as Maintenance or Flashing Light and
Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
34 - THALIA
D814123 0AA00_01
TABLE “B” - LOGIC MENU - (logic)
Logic
Definition
Default
Cross out
setting
used
Optional extras
OTOR TYPE
Motor type
(Set the type of motor
connected to the
board).
0
0
Motors not active
1
ELI 250 BT
2
PHOBOS N BT
3
IGEA BT
4
NOT MANAGED
5
NOT MANAGED
6
SUB BT
7
KUSTOS BT A - PHOBOS BT A
8
GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A50
9
VIRGO SMART BT A - 5 wires
10
VIRGO SMART BT A - 3 wires
11
E5 BT A18
12
E5 BT A12
13
ELI BT A40 LS
14
ELI BT A35 LS
15
ELI BT A35
16
ELI BT A40
TCA
Automatic Closing
Time
0
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
OVE NT
Step-by-step
movement
0
0
Inputs configured as Start E, Start I, Ped operate with 4-step logic.
1
Inputs configured as Start E, Start I, Ped operate with 3-step logic. Pulse during closing reverses movement.
2
Inputs configured as Start E, Start I, Ped operate with 2-step logic. Movement reverses with each pulse.
PRE-ALAR
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
IBL OPEN
Block pulses during
opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
iBL TCA
Block pulses during
TCA
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
IBL CLOSE
Block pulses during
closing
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
RA BLOW C.OP
Hammer during
opening
0
0
Logic not enabled
1
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
RA BLOW C.CL
Hammer during
closing
0
0
Logic not enabled
1
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock
to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
BLOC PERSIST
Stop maintenance
0
0
Logic not enabled
1
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in
the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due
to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
PRESS SWC
Closing limit switch
pressure
0
0
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
limit switch must be adjusted accurately (Fig.G Ref.B).
1
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor inter-
preting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the
mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing
limit switches to trip slightly earlier (Fig.G Ref.A).
ICE
Ice feature
0
0
The Amperostop safety trip threshold stays at the same set value.
1
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than
the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing
cycle.
1 OT.ON
1 motor active
0
0
Both motors active (2 leaves).
1
Only motor 1 active (1 leaf).
THALIA - 35
D814123 0AA00_01
Inversion of the
motor’s phase shift
0
0
Open: M1 starts in advance compared to M2 (opening phase shift). (See Fig.E)
Closure: M2 starts in advance compared to M1 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M1
1
Open: M2 starts in advance compared to M1 (opening phase shift). (See Fig.E)
Closure: M1 starts in advance compared to M2 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M2
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (See Fig.E).
1
Opens in other direction to standard operating mode (See Fig. E)
SAFE 1
Configuration of
safety input SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
9
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
10
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
11
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops.
12
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
13
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
14
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops.
IC 1
Configuration of
command input IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
IC 2
Configuration of
command input IC 2.
62
4
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
AUX 0
Configuration of
AUX 0 output. 20-21
6
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA, gate open light.
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
AUX 3
Configuration of
AUX 3 output.
26-27
0
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
FIXED CODE
Fixed code
0
0
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
Protection
level
Setting the
protection level
0
0
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters
by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the
receiver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
1
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
2
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
3
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
4
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio
interference, if any.
36 - THALIA
D814123 0AA00_01
(Identifies how board
is configured in a BFT
network connection).
0
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
ADDRESS
Address
0
[ ___ ]
Identifies board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
PUSH go
Push&Go
(Only for
E5 BT A12)
0
0
Logic not active
1
Manually pushing the stopped leaf toward the opening direction determines the automatic opening.
EXPI1
Configuration of
EXPI1 input on
input-output expan-
sion board.
1-2
1
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
12
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
13
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
14
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
output expansion board is switched automatically to safety device test input, EXPFAULT1
15
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/
output expansion board is switched automatically to safety device test input, EXPFAULT1
16
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
17
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
18
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
EXPI2
Configuration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
12
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
EXPO1
Configuration of
EXPO1 output
on input-output
expansion board
4-5
11
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
EXPO2
Configuration of
EXPO2 output
on input-output
expansion board
6-7
11
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Traffic Light control with TLB board.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
TRAFFIC LIGHT
PREFLASHING
Traffic light pre-
flashing
0
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LA P
ALWAYS ON
Steadily lit red light
0
0
Red lights off when gate closed.
1
Red lights on when gate closed.
THALIA - 37
D814123 0AA00_01
TABLE “C” – RADIO MENU (RADIO)
Logic
Description
Add start
Add Start Key
associates the desired key with the Start command
add 2ch
Add 2ch Key
associates the desired key with the 2nd radio channel command. Associates the desired key with the 2nd radio channel command. If no output
is configured as 2nd Radio Channel Output, the 2nd radio channel controls the pedestrian opening.
erase 64
Erase List
WARNING! Erases all memorized transmitters from the receiver’s memory.
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
38 - THALIA
D814123 0AA00_01