Advantech PCM-3680 Startup Manual

Specifications

Brand: Advantech
Category: Control Unit
Model: PCM-3680 (Startup Manual)
File Type: PDF
File Size: —
Pages: 4

Read Online

Read the Advantech PCM-3680 Startup Manual online using the built-in PDF viewer.

Text of the manual

1 PCM-3680 Startup Manual All product specifications are subject to change without notice.

STARTUP MANUAL PCM-3680 2-Port CAN-bus PC/104 Module with Isolation Protection Before installation, please make sure that you have: • PCM-3680 • ICOM Series Driver CD with Advantech WDM CAN Driver • Startup Manual If anything is missing or damaged, contact your distributor or sales representative immediately. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reason- able protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residen- tial area is likely to cause interference in which case the user is required to correct interference at his expense CE This product has passed the CE test for environmental spec- ifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ordering information. PCM-3680 is a special purpose communication card that brings the Control Area Network to your PC. With the built-in CAN controller, the PCM-3680 provides bus arbitration and error detection with automatic transmission repeat function. The onboard CAN controllers are located at different positions in the memory. You can run both CAN controllers at the same time, independently. The PCM-3680 operates at baud rates up to 1 Mbps and can be installed directly into the expansion slot of your PC. • Operates 2 CAN networks simultaneously • High speed transmission (up to 1Mbps) • 16 MHz CAN controller frequency • 4 KB address space, 40 base address adjustable in steps from C800H up to EF00H • Optical isolation protection of 2500 VDC • Wide IRQ selection for each port includes: IRQ 3, 4, 5, 6,7, 9, 10, 11, 12, 15 • LED indicates transmit/receive status on each port • Direct memory mapping enables speedy access • Supports 32/64-bit WinXP/Vista/Win7, WinCE 5.0/6.0 and Linux • Ports: 2 • CAN Controller: SJA-1000 • CAN Transceiver: 82C250 • Signal Support: CAN-L, CAN-H • Memory Address: From C800H to EF00H • IRQ: 3, 4, 5, 6, 7, 9, 10, 11,12, 15 • Isolation Voltage: 2500 VDC • Power Consumption: +5 V @ 400 mA typical, 950 mA max. • Connectors: Dual DB-9 male connectors • Operating Temperature: -40 ~ 85°C (-40 ~ 185°F) • PC/104 Form Factor: 3.6" x 3.8" (90 x 96 mm) • Shipping Weight: 0.485 lb (0.22 kg) Packing List Features Declaration of Conformity Overview Notes For more information on this and other Advantech products, please visit our websites at: http://www.advantech.com/eAutomation For technical support and service: http://www.advantech.com/support/ This startup manual is for PCM-3680. Part No. 2000368040 1st Edition June 2011 Specifications Jumper & Switch Locations

2 PCM-3680 Startup Manual

Installation Card Configuration The PCM-3680 has two ports, each with one jumper. The jumpers set the IRQ for the ports, which can be configured separately. A DIP switch sets the memory base address for each port. The following chart shows the function of the jumper and the switch (see the previ- ous page for jumper and switch locations). Default Settings • Port 1 is set for COM1 (IRQ=12, Memory address = DA00:0000). • Port 2 is set for COM2 (IRQ=15, Memory address =DA00:0200). If you need to change these settings, see the following sections. Otherwise, you can simply install the card. Note that you will need to disable your CPU card's onboard COM ports, if any, or set them to alternate addresses/IRQs. Jumpers and Switches Jumpers JP1 and JP2 set the interrupts for Port 1 and Port 2, respectively. You can choose any IRQ from 3 to 15, except 8, 13 and 14. When you choose IRQs, make sure they are not used for other cards in the system. The following figures show the card's default settings. Note: It is suggested to set the terminator resistor (120Ω) to keep the baud rate performance. Switch and Jumper Functions IRQ Setup JP1 Port 1 JP2 Port 2 Memory base address SW1 Port 1, Port 2 JP5/JP6 Setting (Terminator Resistor Setup) Status Value of Terminator Resistor (Ω) Open Mode 0 Close Mode 120 Memory Base Address (SW1) The memory base address for the PCM-3680, which requires 4 KB of address space, is made up of the mem- ory segment and its associated offset. The address for the memory segment is set through SW1, a six-position DIP switch. You can choose any base address from C800 to EF00. The following table shows the DIP switch settings and the corresponding base addresses. Memory Address Configuration (SW1) Address/ DIP Switch A12 A13 A14 A15 A16 A17 C800H on on on off on on C900H off on on off on on CA00H on off on off on on CB00H off off on off on on CC00H on on off off on on CD00H off on off off on on CE00H on off off off on on CF00H off off off off on on D000H on on on on off on D100H off on on on off on D200H on off on on off on D300H off off on on off on D400H on on off on off on D500H off on off on off on D600H on off off on off on D700H off off off on off on D800H on on on off off on D900H off on on off off on DA00H on off on off off on DB00H off off on off off on DC00H on on off off off on DD00H off on off off off on DE00H on off off off off on DF00H off off off off off on E000H on on on on on off E100H of on on on on off E200H on off on on on off E300H off off on on on off E400H on on off on on off E500H off on off on on off E600H on off off on on off E700H off off off on on off E800H on on on off on off E900H off on on off on off EA00H on off on off on off EB00H off off on off on off EC00H on on off off on off ED00H off on off off on off EE00H on off off off on off EF00H off off off off on off

3 PCM-3680 Startup Manual All product specifications are subject to change without notice.

STARTUP MANUAL Memory Area Once the memory segment for the base address is selected, the offset will be automatically assigned for Port 1, Port 2, and hardware reset. The following table shows the base addresses of the CAN control- lers. Software Overview Please install the Advantech CAN WDM Driver before using PCM-3680. You can find the driver in the CD come along with the product. Advantech CAN Windows WDM&CE Driver is composed of bus drivers, ports drivers, tools and examples. Bus drivers and ports drivers, which run in PeliCAN mode, are used to drive SJA1000 chip on Advantech CAN device. Bus drivers and ports drivers are compliant with PCI and ISA bus, and provide the users with coherent operation interfaces. Users can directly write applications with windows API. Examples of VC, VB, VB.NET, C#.NET, VC.NET, eVC are supplied in the package, provid- ing a reference for users to develop applications. When developing work is completed, users can use test tools to verify if functions of the application are correct. Installation After the installation of the driver, please start the “Add Hardware Wizard” to add the hardware device. Then follow the steps as shown in the figures below. Base address (hex) CAN Controller base:0000h - base:00FFh Basic- Port 1 base:0100h - base:01FFh HW reset Basic - Port 1 base:0200h - base:02FFh Basic- Port 2 base:0300h - base:03FFh HW reset Basic - Port 2 base:0400h - base:0FFFh Not used DataMonitor Utility

4 PCM-3680 Startup Manual

Configuration Before you start to use PCM-3680, you must configure the CAN resource. You can refer to the below figures to set the Memory Address and IRQ.