Craftsman 919.15216 Owner's Manual
Read Online
Read the Craftsman 919.15216 Owner's Manual online using the built-in PDF viewer.
Text of the manual
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
Model No.
919.152160
CAUTION: Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
N014212 Rev. 0 7/24/08
2 - ENG
N014212
TABLE OF CONTENTS
WARRANTY
ONE YEAR FULL WARRANTY
If this product fails due to a defect in material or workmanship within one year
from the date of purchase, Sears will at its option repair or replace it free of
charge. Contact Sears at 1-800-4-MY-HOME® to arrange for repair, or return it
to the place of purchase for replacement.
If this product is used for commercial or rental purposes, this warranty applies
for only ninety days from the date of purchase.
This warranty gives you specific legal rights and you may have other rights
which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFICATION CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SAFETY GUIDELINES - DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
duty cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-14
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
SERVICE AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-19
REPAIR PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-23
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-41
REPAIR PROTECTION AGREEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
HOW TO ORDER REPAIR PARTS . . . . . . . . . . . . . . . . . . . . . . . back cover
3 - ENG
N014212
SPECIFICATION CHART
Model No.
919.152160
Running HP
0.8*
Bore
1-7/8"
Stroke
1-1/4"
Voltage-Single Phase
120V
Minimum Branch Circuit Requirement
10 amps
Fuse Type
Time Delay
Air Tank Capacity
6 gallon
Approx. Cut-In
120 PSI
Approx. Cut-out
150 PSI
SCFM @ 40 psig
3.7*
SCFM @ 90 psig
2.6*
*Tested per ISO 1217
Refer to Glossary for abbreviations.
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and under-
stand. This information relates to protecting YOUR SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To help you recognize this information, we use the
symbols below. Please read the manual and pay attention to these symbols.
Indicates an
imminently hazardous
situation which, if not avoided, will
result in death or serious injury.
Indicates a potentially
hazardous situation
which, if not avoided, may result in
minor or moderate injury.
Indicates a potentially
hazardous situation
which, if not avoided, could result in
death or serious injury.
Used without the
safety alert symbol
indicates a potentially hazardous
situation which, if not avoided, may
result in property damage.
IMPORTANT SAFETY INSTRUCTIONS
This product contains chemicals known to the State of
California to cause cancer, and birth defects or other
reproductive harm. Wash hands after handling.
Some dust contains chemicals known to the State
of California to cause cancer, birth defects or other
reproductive harm such as asbestos and lead in lead based paint.
Do not operate this unit until you read and
understand this instruction manual for safety,
operation and maintenance instructions.
SAVE THESE INSTRUCTIONS
4 - ENG
N014212
HAZARD
Risk of explosion or fire
What can happen
How to prevent it
•
It is normal for electrical contacts
within the motor and pressure
switch to spark.
•
Always operate the compressor in a
well ventilated area free of combus-
tible materials, gasoline, or solvent
vapors.
•
If electrical sparks from compressor
come into contact with flammable
vapors, they may ignite, causing fire
or explosion.
•
If spraying flammable materials,
locate compressor at least 20 feet
(6.1 m) away from spray area. An
additional length of air hose may be
required.
•
Store flammable materials in a
secure location away from com-
pressor.
•
Restricting any of the compressor
ventilation openings will cause seri-
ous overheating and could cause
fire.
•
Never place objects against or on
top of compressor.
•
Operate compressor in an open
area at least 12" (30.5 cm) away
from any wall or obstruction that
would restrict the flow of fresh air to
the ventilation openings.
•
Operate compressor in a clean, dry
well ventilated area. Do not operate
unit indoors or in any confined area.
•
Unattended operation of this prod-
uct could result in personal injury
or property damage. To reduce the
risk of fire, do not allow the com-
pressor to operate unattended.
•
Always remain in attendance with
the product when it is operating.
•
Always turn off and unplug unit
when not in use.
HAZARD
RISK TO BREATHING (Asphyxiation)
What can happen
How to prevent it
•
The compressed air directly from
your compressor is not safe for
breathing. The air stream may
contain carbon monoxide, toxic
vapors, or solid particles from the
air tank. Breathing these contami-
nants can cause serious injury or
death.
•
Air obtained directly from the com-
pressor should never be used to
supply air for human consumption.
In order to use air produced by this
compressor for breathing, suitable
filters and in-line safety equipment
must be properly installed. In-line
filters and safety equipment used
in conjunction with the compres-
sor must be capable of treating air
to all applicable local and federal
codes prior to human consump-
tion.
5 - ENG
N014212
• Exposure to chemicals in dust cre-
ated by power sanding, sawing,
grinding, drilling, and other con-
struction activities may be harmful.
• Sprayed materials such as paint,
paint solvents, paint remover, insec-
ticides, weed killers, may contain
harmful vapors and poisons.
• Work in an area with good cross
ventilation. Read and follow the
safety instructions provided on the
label or safety data sheets for the
materials you are spraying. Always
use certified safety equipment:
NIOSH/OSHA respiratory protec-
tion or properly fitting face mask
designed for use with your specific
application.
HAZARD
RISK of Bursting
Air Tank: The air tank on your Air Compressor is designed and may be UM coded
(for units with air tanks greater than 6" (122 mm) diameter) according to ASME
Section VIII, Div. 1 rules. All pressure vessels should be inspected once every two
years. To find your state pressure vessels inspector, look under the Division of Labor
and Industries in the government section of a phone book .
The following conditions could lead to a weakening of the air tank, and result in a
violent air tank explosion:
What can happen
How to prevent it
•
Failure to properly drain condensed
water from air tank, causing rust
and thinning of the steel air tank.
•
Drain air tank daily or after each
use. If air tank develops a leak,
replace it immediately with a
new air tank or replace the entire
compressor.
•
Modifications or attempted repairs
to the air tank.
•
Never drill into, weld, or make any
modifications to the air tank or its
attachments. Never attempt to
repair a damaged or leaking air
tank. Replace with a new air tank.
•
Unauthorized modifications to
the safety valve or any other
components which control air tank
pressure.
•
The air tank is designed to
withstand specific operating
pressures. Never make adjustments
or parts substitutions to alter the
factory set operating pressures.
Attachments & accessories:
•
Exceeding the pressure rating of
air tools, spray guns, air operated
accessories, tires, and other
inflatables can cause them to
explode or fly apart, and could
result in serious injury.
•
Follow the equipment
manufacturers recommendation
and never exceed the maximum
allowable pressure rating of
attachments. Never use compressor
to inflate small low pressure objects
such as children’s toys, footballs,
basketballs, etc.
6 - ENG
N014212
Tires:
•
Over inflation of tires could result in
serious injury and property damage.
•
Use a tire pressure gauge to check
the tires pressure before each use
and while inflating tires; see the tire
sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and simi-
lar equipment used to inflate tires can fill
small tires similar to these very rapidly.
Adjust pressure regulator on air supply to
no more than the rating of the tire pres-
sure. Add air in small increments and fre-
quently use the tire gauge to prevent over
inflation.
HAZARD
Risk of Electrical Shock
What can happen
How to prevent it
•
Your air compressor is powered by
electricity. Like any other electrically
powered device, If it is not used
properly it may cause electric
shock.
•
Never operate the compressor
outdoors when it is raining or in wet
conditions.
•
Never operate compressor with
protective covers removed or
damaged.
•
Repairs attempted by unqualified
personnel can result in serious
injury or death by electrocution.
•
Any electrical wiring or repairs
required on this product should be
performed by authorized service
center personnel in accordance with
national and local electrical codes.
•
Electrical Grounding: Failure to
provide adequate grounding to
this product could result in serious
injury or death from electrocution.
Refer to Grounding Instructions
paragraph in the Installation
section.
•
Make certain that the electrical
circuit to which the compressor
is connected provides proper
electrical grounding, correct voltage
and adequate fuse protection.
7 - ENG
N014212
HAZARD
Risk from Flying Objects
What can happen
How to prevent it
•
The compressed air stream can
cause soft tissue damage to
exposed skin and can propel dirt,
chips, loose particles, and small
objects at high speed, resulting in
property damage or personal injury.
•
Always wear certified safety equip-
ment: ANSI Z87.1 eye protection
(CAN/CSA Z94.3) with side shields
when using the compressor.
•
Never point any nozzle or sprayer
toward any part of the body or at
other people or animals.
•
Always turn the compressor off
and bleed pressure from the air
hose and air tank before attempt-
ing maintenance, attaching tools or
accessories.
HAZARD
RISK OF Hot surfaces
What can happen
How to prevent it
•
Touching exposed metal such as
the compressor head, engine head,
engine exhaust or outlet tubes, can
result in serious burns.
•
Never touch any exposed metal
parts on compressor during or
immediately after operation.
Compressor will remain hot for
several minutes after operation.
•
Do not reach around protective
shrouds or attempt maintenance
until unit has been allowed to cool.
HAZARD
Risk from Moving Parts
What can happen
How to prevent it
•
Moving parts such as the pulley, fly-
wheel, and belt can cause serious
injury if they come into contact with
you or your clothing.
•
Never operate the compressor with
guards or covers which are dam-
aged or removed.
•
Keep your hair, clothing, and gloves
away from moving parts. Loose
clothes, jewelry, or long hair can be
caught in moving parts.
•
Air vents may cover moving parts
and should be avoided as well.
•
Attempting to operate compressor
with damaged or missing parts or
attempting to repair compressor
with protective shrouds removed
can expose you to moving parts
and can result in serious injury.
•
Any repairs required on this product
should be performed by authorized
service center personnel.
8 - ENG
N014212
HAZARD
Risk of Unsafe Operation
What can happen
How to prevent it
•
Unsafe operation of your air com-
pressor could lead to serious injury
or death to you or others.
•
Review and understand all instruc-
tions and warnings in this manual.
•
Become familiar with the operation
and controls of the air compressor.
•
Keep operating area clear of all per-
sons, pets, and obstacles.
•
Keep children away from the air
compressor at all times.
•
Do not operate the product when
fatigued or under the influence of
alcohol or drugs. Stay alert at all
times.
•
Never defeat the safety features of
this product.
•
Equip area of operation with a fire
extinguisher.
•
Do not operate machine with miss-
ing, broken, or unauthorized parts.
HAZARD
Risk of Falling
What can happen
How to prevent it
•
A portable compressor can fall
from a table, workbench, or roof
causing damage to the compres-
sor and could result in serious
injury or death to the operator.
•
Always operate compressor in a
stable secure position to prevent
accidental movement of the unit.
Never operate compressor on a
roof or other elevated position.
Use additional air hose to reach
high locations.
HAZARD
risk from noise
What can happen
How to prevent it
•
Under some conditions and dura-
tion of use, noise from this product
may contribute to hearing loss.
•
Always wear certified safety equip-
ment: ANSI S12.6 (S3.19) hearing
protection.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
9 - ENG
N014212
GLOSSARY
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per min-
ute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge;
a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor
is off, air tank pressure drops as you
Accessories
•
In Line Filter
•
Tire Air Chuck
•
Quick Connector Sets
(various sizes)
•
Air Pressure Regulators
•
Oil Fog Lubricators
•
Air Hose: 1/4", 3/8" or 1/2" I.D. in
various lengths
Refer to the selection chart located on
the unit to select the tools this unit is
capable of powering.
The use of any
other accessory
not recommended for use with
this tool could be hazardous. Use
only accessories rated equal to
or higher than the rating of the air
compressor.
ACCESSORIES
This unit is capable of powering the following accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
average duty cycle be maintained;
that is, the air compressor pump
should not run more than 30-45
minutes in any given hour.
continue to use your accessory. When
the tank pressure drops to a certain
low level the motor will restart auto-
matically. The low pressure at which
the motor automatically restarts is
called "cut-in" pressure.
Cut-Out Pressure: When an air com-
pressor is turned on and begins to
run, air pressure in the air tank begins
to build. It builds to a certain high
pressure before the motor automati-
cally shuts off, protecting your air tank
from pressure higher than its capacity.
The high pressure at which the motor
shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
duty cycle
This air compressor pump is capable
of running continuously. However, to
prolong the life of your air compressor,
it is recommended that a 50%-75%
10 - ENG
N014212
assembly
Unpacking
1.
Remove unit from carton and discard all packaging.
INSTALLATION
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
•
Locate the air compressor in a
clean, dry and well ventilated
area.
•
The air compressor should be
located at least 12" (30.5 cm)
away from the wall or other
obstructions that will interfere
with the flow of air.
•
The air compressor pump and
shroud are designed to allow for
proper cooling. The ventilation
openings on the compressor are
necessary to maintain proper
operating temperature. Do not
place rags or other containers on
or near these openings.
Grounding Instructions
Risk of Electrical
Shock. In the event
of a short circuit, grounding reduces
the risk of shock by providing an
escape wire for the electric current.
This air compressor must be
properly grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations).
1.
The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2.
Make sure the outlet being used
has the same configuration as the
grounded plug. DO NOT USE AN
ADAPTER. See illustration.
Grounding Pin
Grounded
Outlets
Plug
3.
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4.
If these grounding instructions are
not completely understood, or if in
doubt as to whether the compres-
sor is properly grounded, have the
installation checked by a qualified
electrician.
Risk of Electrical
Shock. IMPROPER
GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed by
a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified elec-
trician.
11 - ENG
N014212
Extension Cords
If an extension cord must be used, be
sure it is:
•
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3‑slot receptacle that will accept
the plug on the product
•
in good condition
•
no longer than 50 feet
•
14 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 12 AWG and 10 AWG
may also be used. DO NOT USE
16 OR 18 AWG.)
The use of an
undersized
extension cord will cause voltage to
drop resulting in power loss to the
motor and overheating. Instead of
using an extension cord, increase
the working reach of the air hose by
attaching another length of hose to its
end. Attach additional lengths of hose
as needed.
Voltage and Circuit Protection
Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
Risk of Opertion.
Certain air
compressors can be operated on
a 15 amp circuit if the following
conditions are met.
1.
Voltage supply to circuit must
comply with the National
Electrical Code.
2.
Circuit is not used to supply any
other electrical needs.
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse. NOTE: If compressor
is connected to a circuit protected
by fuses, use only time delay
fuses. Time delay fuses should be
marked "D" in Canada and "T" in
the US.
If any of the above conditions cannot
be met, or if operation of the compres-
sor repeatedly causes interruption
of the power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
12 - ENG
N014212
controlled by the regulator and is
always less than or equal to the tank
pressure.
Regulator: Controls the air pressure
shown on the outlet pressure
gauge. Turn regulator knob
clockwise to increase pressure
and counterclockwise to decrease
pressure.
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan
to blow air through the vent holes
in large amounts. You know that the
cooling system is working when air is
being expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the air
outlet.
Drain Valve:
Drain
Valve
The drain valve
is located at
the base of the
air tank and is
used to drain
condensation at the end of each use.
Description of Operation
Become familiar with these controls
before operating the unit.
On(I)/Off(O) Switch: Place this switch
in the On (I) position to provide
automatic power to the pressure
switch and Off (O) to remove power at
the end of each use.
Pressure Switch (not shown): The
pressure switch automatically starts
the motor when the air tank pressure
drops below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its
factory set pressure (slightly higher
than the pressure switch "cut-out"
setting).
Tank Pressure Gauge: The tank
pressure gauge indicates the reserve
air pressure in the tank.
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air
pressure available at the outlet side
of the regulator. This pressure is
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.
Outlet
Pressure
Gauge
Safety Valve
Regulator
Tank
Pressure
Gauge
On(I)/Off(O) Switch
Quick
Connect
13 - ENG
N014212
Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the
air compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Check
Valve
Motor Overload Protector (not
shown): The motor has an automatic
reset thermal overload protector. If
the motor overheats for any reason,
the overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. The
compressor will automatically restart
after the motor cools.
How to Use Your Unit
How to Stop
1.
Set the On/Off switch to "Off" .
Before Starting
Do not operate this
unit until you read
and understand this instruction
manual for safety, operation and
maintenance instructions.
Break-in Procedure
Risk of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not closely
followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1.
Make sure the On/Off switch is in
the "Off" position.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in
the Installation section of
this manual.)
3.
Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
4.
Move the On/Off switch to "On"
position. The compressor will start.
5.
Run the compressor for 15 min-
utes. Make sure the drain valve
is open and there is minimal air
pressure build-up in tank.
6.
After 15 minutes, close the drain
valve by turning clockwise. The
air receiver will fill to "cut-out"
pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up
1.
Set the On/Off switch to "Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Attach hose and accessories.
Risk of unsafe
operation. Firmly
grasp air hose in hand when
installing or disconnecting to
prevent hose whip.
Risk of unsafe
operation. Do not
use damaged or worn accessories.
NOTE: The hose or accessory will
require a quick connect plug if the air
outlet is equipped with a quick con-
nect socket.
Risk of Bursting.
Too much air
pressure causes a hazardous risk of
bursting. Check the manufacturer’s
maximum pressure rating for air
tools and accessories. The regulator
outlet pressure must never exceed
the maximum pressure rating.
Risk of unsafe
operation.
Compressed air from the unit may
contain water condensation and
oil mist. Do not spray unfiltered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered
air. Read the instructions for the air
tools and accessories.
14 - ENG
N014212
MAINTENANCE
Customer Responsibilities
Before
each
use
Daily
or after
each
use
Check Safety Valve
X
Drain Tank
X
Unit cycles
automatically when
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
NOTE: See Operation section for the
location of controls.
To Check Safety Valve
Risk of Bursting.
If the safety valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
Risk from Flying
Objects. Always
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/CSA
Z94.3) with side shields
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced with
the same type of valve.
To Drain Tank
Risk of Unsafe
Operation. Risk
from noise. Air tanks contain high
pressure air. Keep face and other
body parts away from outlet of
drain. Use ANSI Z87.1 eye protection
(CAN/CSA Z94.3) when draining as
debris can be kicked up into face.
Use ear protection [(ANSI S12.6
(S3.19)] hearing protection) as air
flow noise is loud when draining.
1.
Set the On/Off switch to "Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve on bottom of
tank.
Risk of Bursting.
Water will condense
in the air tank. If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.
How to Start:
1.
Set the On/Off switch to "On"
and allow tank pressure to build.
Motor will stop when tank pressure
reaches "cut-out" pressure.
2.
Turn regulator knob clockwise to
increase pressure and stop when
desired pressure is reached.
If any unusual
noise or vibration
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
15 - ENG
N014212
To Replace or Clean Check
Valve
1.
Release all air pressure from air
tank. See To Drain Tank in the
Maintenance section.
2.
Unplug unit.
3.
Remove the hose by removing
the hose clamp. NOTE: The hose
clamp is not reusable. You must
purchase a new hose clamp,
see the Parts List or purchase a
standard hose clamp at a local
hardware store.
Check
Valve
Hose
Clamp
4.
Unscrew the check valve (turn
counter-clockwise) using a socket
wrench.
5.
Make sure the valve disc moves
freely inside the check valve and
the spring holds the disc in the
upper, closed position. The check
valve may be cleaned with a
solvent, such as paint and varnish
remover.
SERVICE AND ADJUSTMENTS
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to
voltage sources, compressed air, or moving parts. Before servicing unit
unplug or disconnect electrical supply to the air compressor, bleed tank of
pressure, and allow the air compressor to cool.
6.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
7.
Replace hose and new hose
clamp.
8.
Perform the Break-in Procedure.
See Break-in Procedure in the
Operation section.
To Replace Regulator Manifold
1.
Release all air pressure from air
tank. See To Drain Tank in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench
remove the safety valve from the
regulator manifold.
Safety
Valve
Regulator
Manifold
Risk of Property
Damage. Drain
water from air tank may contain oil
and rust which can cause stains.
6.
After the water has been drained,
close the drain valve. The air
compressor can now be stored.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
16 - ENG
N014212
6.
Carefully slide pump from
brackets and out of the way.
Pump
shown
moved out
of the way
Regulator
Manifold
7.
Using an adjustable wrench
remove the regulator manifold.
8.
Apply pipe sealant to new
regulator manifold and assemble,
tighten with wrench.
9.
Reapply pipe sealant to safety
valve.
10. Reassemble all components in
reverse order of removal. Make
sure to orient gauges to read
correctly and use wrenches to
tighten all components.
4.
Remove the hose by removing
the hose clamp. NOTE: The hose
clamp is not reusable. You must
purchase a new hose clamp,
see the Parts List or purchase a
standard hose clamp at a local
hardware store.
Regulator
Manifold
Hose Clamp
5.
Remove pump mounting screws
securing pump (one on each side).
Pump Mounting Screw
STORAGE
Before you store the air compressor,
make sure you do the following:
1.
Review the Maintenance section
on the preceding pages and
perform scheduled maintenance
as necessary.
2.
Set the On/Off switch to "Off" and
unplug unit.
3.
Turn the regulator counterclock-
wise and set the outlet pressure to
zero.
4.
Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6.
Drain water from air tank by
opening drain valve on bottom of
tank.
Risk of Bursting.
Water will condense
in the air tank. If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.
7.
After the water has been drained,
close drain valve by turning
clockwise.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
8.
Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor handle.
9.
Store the air compressor in a
clean and dry location.
17 - ENG
N014212
TROUBLESHOOTING
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to
voltage sources, compressed air, or moving parts. Before servicing unit
unplug or disconnect electrical supply to the air compressor, bleed tank of
pressure, and allow the air compressor to cool.
PROBLEM
CAUSE
CORRECTION
Excessive tank pressure
- safety valve pops off.
Pressure switch does
not shut off motor when
compressor reaches
"cut-out" pressure.
Move On/Off lever to
the "Off" position, if
the outfit does not shut
off contact a Trained
Service Technician.
Pressure switch "cut-
out" too high.
Contact a Trained
Service Technician.
Air leaks at fittings.
Tube fittings are not tight
enough.
Tighten fittings where air
can be heard escaping.
Check fittings with
soapy water solution. Do
Not Overtighten.
Air leaks in air tank or at
air tank welds.
Defective air tank.
Air tank must be
replaced. Do not repair
the leak.
Risk bursting. Do
not drill into, weld or
otherwise modify air
tank or it will weaken.
The tank can rupture
or explode.
Air leaks between head
and valve plate.
Leaking seal.
Contact a Trained
Service Technician.
Air leak from safety
valve.
Possible defect in safety
valve.
Operate safety valve
manually by pulling on
ring. If valve still leaks, it
should be replaced.
Knocking Noise.
Possible defect in safety
valve.
Operate safety valve
manually by pulling on
ring. If valve still leaks, it
should be replaced.
18 - ENG
N014212
PROBLEM
CAUSE
CORRECTION
Pressure reading on
the regulated pressure
gauge drops when an
accessory is used.
It is normal for "some"
pressure drop to occur.
If there is an excessive
amount of pressure drop
when the accessory
is used, adjust the
regulator following
the instructions in
the Description of
Operation paragraph in
the Operation Section.
NOTE: Adjust the
regulated pressure under
flow conditions (while
accessory is being
used).
Compressor is not sup-
plying enough air to
operate accessories.
Prolonged excessive use
of air.
Decrease amount of air
usage.
Compressor is not large
enough for air require-
ment.
Check the accessory
air requirement. If it is
higher than the SCFM
or pressure supplied
by your air compressor,
you need a larger
compressor.
Hole in hose.
Check and replace if
required.
Check valve restricted.
Remove and clean, or
replace.
Air leaks.
Tighten fittings.
Regulator knob has con-
tinuous air leak.
Damaged regulator.
Replace.
19 - ENG
N014212
PROBLEM
CAUSE
CORRECTION
Regulator will not shut
off air outlet.
Damaged regulator.
Replace.
Motor will not run.
Fuse blown, circuit
breaker tripped.
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Extension cord is wrong
length or gauge.
Check the extension
cord.
Loose electrical
connections.
Check wiring
connection inside
terminal box.
Faulty motor.
Have checked by
a Trained Service
Technician.
Motor overload protec-
tion switch has tripped
Refer to Motor
Overload Protection
under Operation.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician.
20 - ENG
N014212
AIR COMPRESSOR DIAGRAM
Air Compressor Model Number 919.152160
PARTS SHOWN FOR REFERENCE ONLY
Contratos de Protección Maestra
Felicitaciones por hacer una compra
inteligente. Su nueva unidad Craftsman® está
diseñada y fabricada para años de operación
confiable; pero como todos los productos
de calidad, podría requirir reparaciones de
vez en cuando. Ahí es cuando el Contrato de
Protección Maestra le puede ahorrar dinero y
molestias.
Compre ahora un Contrato de Protección
Maestra y protéjase contra apuros y gastos
inesperados.
El Contrato de Protección Maestra también
permite prolongar la vida útil de su nueva
unidad.
Este contrato incluye lo siguiente:
Servicio Experto a cargo de uno de nuestros
12.000 profesionales especializados en
reparaciones.
Servicio ilimitado sin cargo por repuestos
y mano de obra en todas las reparaciones
cubiertas.
Garantía por defectos de fábrica: cubre
el reemplazo de su unidad si dentro de los
doce meses ocurren cuatro o más fallas.
Reemplazo de la unidad si su unidad
cubierta no puede repararse.
Control Anual de Mantenimiento
Preventivo a su solicitud, sin cargo adicional.
Asistencia telefónica rápida a cargo de
personal técnico de soporte de Sears para
las unidades que requieran repararse en
su domicilio en horarios convenientes para
usted.
Protección contra los daños ocasionados
por sobretensión transitoria debido a
fluctuaciones de energía.
Reembolso de alquiler si la reparación de
su unidad cubierta lleva más tiempo del
prometido.
Una vez que usted compre su Contrato, sólo
necesita hacer una simple llamada telefónica
para programar su servicio. Puede llamar a
cualquier hora del día o la noche, o puede
programar su servicio en línea vía Internet.
Sears tiene más de 12.000 profesionales
especializados en reparaciones que tienen
acceso a más 4,5 millones de repuestos
y accesorios de calidad. Ése es el tipo de
profesionalismo con el cual usted puede
contar, que le ayudará a prologar la vida útil
de su unidad durante todos los años por
venir. ¡Compre hoy su Contrato de Protección
Maestra!
Se aplican algunas limitaciones y exclusiones.
Para precios e información adicional, llame al
1-800-827-6655.
Servicio de Instalaciones de Sears
Para instalaciones profesionales de artefactos
para el hogar a cargo de Sears, como abridores
de puertas de garajes, calentadores de agua y
otros artefactos grandes del hogar, en EE.UU.
llame al 1-800-4-MY-HOME®.
Master Protection Agreements
Congratulations on making a smart purchase.
Your new Craftsman® product is designed and
manufactured for years of dependable operation.
But like all products, it may require preventive
maintenance or repair from time to time. That's
when having a Master Protection Agreement can
save you money and aggravation.
Purchase a Master Protection Agreement now
and protect yourself from unexpected hassle
and expense.
The Master Protection Agreement also helps
extend the life of your new product. Here's
what's included in the Agreement:
Expert service by our 12,000 professional
repair specialists
Unlimited service and no charge for parts
and labor on all covered repairs
"No-lemon" guarantee – replacement of
your covered product if four or more product
failures occur within twelve months
Product replacement if your covered product
can't be fixed
Annual Preventive Maintenance Check at
your request – no extra charge
Fast help by phone - phone support from
a Sears technician on products requiring
in-home repair, plus convenient repair
scheduling
Power surge protection against electrical
damage due to power fluctuations
Rental reimbursement if repair of your
covered product takes longer than promised
Once you purchase the Agreement, a simple
phone call is all that it takes for you to schedule
service. You can call anytime day or night, or
schedule a service appointment online.
Sears has over 12,000 professional repair
specialists, who have access to over 4.5 million
quality parts and accessories. That's the kind
of professionalism you can count on to help
prolong the life of your new purchase for years
to come. Purchase your Master Protection
Agreement today!
Some limitations and exclusions apply. For
prices and additional information call 1-800-
827-6655.
Sears Installation Service
For Sears professional installation of home
appliances, garage door openers, water heaters,
and other major home items, in the U.S.A. call
1-800-4-MY-HOME®
Para pedir servicio de reparación
a domicilio, y para ordenar piezas:
1-888-SU-HOGARSM
(1-888-784-6427)
Au Canada pour service en français:
1-800-LE-FOYERMC
(1-800-533-6937)
www.sears.ca
To purchase a protection agreement (U.S.A.)
or maintenance agreement (Canada) on a product serviced by Sears:
1-800-827-6655 (U.S.A.) 1-800-361-6665 (Canada)
Our Home
For repair of carry-in products like vacuums, lawn equipment,
and electronics, call or go on-line for the nearest
Sears Parts and Repair Center.
1-800-488-1222 Anytime, day or night (U.S.A. only)
www.sears.com
Your Home
For repair – in your home – of all major brand appliances,
lawn and garden equipment, or heating and cooling systems,
no matter who made it, no matter who sold it!
For the replacement parts, accessories and
owner’s manuals that you need to do-it-yourself.
For Sears professional installation of home appliances
and items like garage door openers and water heaters.
1-800-4-MY-HOME®
Anytime, day or night
(1-800-469-4663) (U.S.A. and Canada)
www.sears.com www.sears.ca
Get it fixed, at your home or ours!
© Sears, Roebuck and Co.
® Registered Trademark / TM Trademark / SM Service Mark of Sears, Roebuck and Co.
® Marca Registrada / TM Marca de Fábrica / SM Marca de Servicio de Sears, Roebuck and Co.
MC Marque de commerce / MD Marque déposée de Sears, Roebuck and Co.