Datalogic Memor Manual
Text of the manual
Datalogic Memor™ Multi-Battery Charger
Figure 1
The Datalogic Memor Multi-Battery Charger, with its 4 slots,
allows you to charge the Datalogic Memor battery packs.
The Datalogic Memor Multi-Battery Charger is compatible with
the following batteries:
−
94ACC1367 Dl-Memor Large Capacity Battery Cvr2,
ETI CA Battery Inc. P/N BP08-000610, 3.7V 2000mAh TYP
−
94ACC1368 Dl-Memor Standard Battery Cvr2,
ETI CA Battery Inc. P/N BP08-000600, 3.7V 1100mAh TYP
−
94ACC0083 Memor X3 Standard Battery
Model: Standard, Memor X3, 3.7V 1430 mAh TYP
−
94ACC0084 Memor X3 Large Capacity Battery
Model: Extended, Memor X3, 3.7V 2300mAh TYP
Annual replacement of rechargeable battery
pack avoids possible risks or abnormalities and
ensures maximum performance.
CAUTION
822000924 (Rev. A) Nov. 2017
SET UP AND USE
Plug the power supply into the connector positioned on the
Datalogic Memor Multi-Battery Charger base. Then plug the
power supply into a socket.
Figure 2
Insert the battery pack into one of the free slots with the battery
contacts oriented toward the charger back by simply pressing
downward until the battery snaps in place.
Figure 3
The Datalogic Memor Multi-Battery Charger
could get warm during charging, this is normal
and does not mean a malfunction.
NOTE
WARNING
Installing, charging and/or any other action
should be done by authorized personnel and
following this manual.
The battery pack may get hot, explode, ignite,
and/or cause serious injury if exposed to
abusive conditions.
If the battery pack is replaced with an improper
type, there is risk of explosion.
Do not place the battery pack in or near a fire
or heat; do not place the battery pack in direct
sunlight, or use or store the battery pack inside
unventilated areas in hot weather; do not place
the battery pack in microwave ovens, dryer,
high
pressure
containers,
on
induction
cookware or similar device. Doing so may
cause the battery pack to generate heat,
explode or ignite. Using the battery pack in this
manner
may
also
result
in
a
loss
of
performance and a shortened life expectancy.
Use only a Datalogic approved power supply.
The use of an alternative power supply will void
the product warranty, may cause product
damage and may cause heat, explode or ignite.
The area in which the units are charged should
be clear of debris and combustible materials or
chemicals.
Immediately discontinue use of the battery
pack if, while using, charging or storing the
battery pack, the battery pack emits an unusual
smell, feels hot, changes colour or shape, or
appears abnormal in any other way.
Do not short-circuit the battery pack contacts
connecting the positive terminal and negative
terminal. This might happen, for example, when
you carry a spare battery pack in your pocket
or purse; accidental short–circuiting can occur
when a metallic object such as a coin, clip, or
pen causes direct connection of the contacts of
the battery pack (these look like metal strips on
the battery pack). Short–circuiting the terminals
may damage the battery pack or the connecting
object.
Power on
Battery Charging
State LEDs
Do not apply voltages to the battery pack
contacts.
Do not pierce the battery pack with nails, strike
it with a hammer, step on it or otherwise
subject it to strong impacts or shocks.
Do not disassemble or modify (i.e. bend, crush
or deform) the battery pack. The battery pack
contains safety and protection devices, which,
if damaged, may cause the battery pack to
generate heat, explode or ignite.
In case of leakage of liquid from the battery,
avoid contact with liquid the skin or eyes. If the
contact occurs, immediately wash the affected
area with water and consult a doctor.
Do not solder directly onto the battery pack.
Do not expose the battery pack to liquids.
Avoid any knocks or excessive vibrations. If
the device or the battery is dropped, especially
on a hard surface, you should take it to the
nearest
Authorised
Repair
Centre
for
inspection before continuing to use it.
Do not remove or damage the battery pack’s
label.
Do not use the battery pack if it is damaged in
any part.
Battery pack usage by children should be
supervised.
Collect and recycle waste batteries separately
from the device in comply with European
Directive
2006/66/EC,
2002/95/EC,
2002/96/EC and subsequent modifications, US
and China regulatory and others laws and
regulations about environment.
BATTERY CHARGING STATUS LED DESCRIPTION
LED
Status
Power
Green
It is constant when the battery
charger is powered
Charger
Off
Empty slot
Red Constant
Charging
Green Constant
Charge completed
Orange Constant
Failure
TECHNICAL FEATURES
ELECTRICAL
Power supply
5 V*
Max consumption
3 A
Charge time
1100 mAh Battery: max. 4 hours
2000 mAh Battery: max. 6 hours
1430 mAh Li-Ion Battery: max. 5 hours
2300 mAh Li-Ion Battery: max. 7 hours
PHYSICAL
Dimensions
21.5 x 8.5 x 7 cm
Weight (without batteries)
450 g
LEDs
4 Charger Status LEDs
1 Power on LED
ENVIRONMENTAL
Working temperature
0° to +50 °C**
Storage temperature
-20° to +70 °C
Humidity
80% without condensation
*
Recommended power supply: 94ACC1324 PG5-30P35
AC/DC POWER SUPPLY EU/USA PLUG
**
All the batteries must be charged at a temperature
ranging from 0° to +35 °C.
Even if the storage temperature range is wider, In
order to achieve the longest battery life, store the
spare batteries between 20 to 30 ºC (68 to 86 ºF).
NOTE
COMPLIANCE
FCC Compliance
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
This device has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiated radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
− Reorient or relocate the receiving antenna.
− Increase the separation between the equipment and
receiver.
− Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
− Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user‘s authority to
operate the equipment.
Industry Canada (ICES-003) Compliance
This Class B digital apparatus complies with Canadian ICES-
003.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
©2008-2017 Datalogic S.p.A. and/or its affiliates. All rights reserved.
Datalogic and the Datalogic logo are registered trademarks of Datalogic
S.p.A. in many countries, including the U.S. and the E.U. Memor is a
trademark of Datalogic S.p.A. and/or its affiliates. All other brand and
product names may be trademarks of their respective owners.
www.datalogic.com