Lisez attentivement ce manuel avant d'installer ou d'utiliser votre nouveau climatiseur. Assurez-
vous de conserver ce manuel.
Installation Manual
XDA
R32
English, Français, Deutch, Italian, Espanol,
Portugues
21.AW.XDA.R32.IM.ML.08.02
1 - Generalities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 - Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 - Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4 - Electrical wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R32, a fluorinated greenhouse gas with
a global warming potential (GWP) of 675.
Do not release R32 into the atmosphere.
R32: 0,39 kg / 0,26 Tonn. CO2 eq.
This symbol refers to a hazard or unsafe practice which can result in severe personal
injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury
or product or property damage.
WARNING
CAUTION
IMPORTANT!
Please read before installation
This air conditioner meets strict safety and operating standards.
For the installer or service person, it is important to install or service the air conditioner so that it operates safely and
efficiently.
Power Supply:
220 - 240 V ~ / 1 / 50 Hz
The unit contains R32, a slightly flammable gas.
•
Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those
recommended by the manufacturer.
•
The unit has to be stored in a room that doesn’t have any continuously operating ignition sources (for example:
open flames, an operating gas appliance or an operating electric heater).
•
Do not pierce or burn the unit.
•
Be aware that refrigerants do not have any odour.
•
This unit has to be installed, operated and stored in a room with a floor area larger than 3m
2. The room must
be well ventilated.
IN CASE OF MAINTENANCE OF THE REFRIGERANT CIRCUIT
•
The installer must be in possession of the F-GAS certification without any integration.
•
The installer must have the appropriate equipment (vacuum pump and recuperator) certified for R32.
Before installing the unit, read this installation manual and streactly follow all safety instructions.
Always contact an Airwell Service Center.
Any repair must be performed by qualified personnel, following the instructions contained in the
manufacturer’s technical manual.
IMPORTANT
Recommendations
• The personnel responsible for receiving the air conditioner must conduct a visual inspection in order to identify all
damage to which it may have been subjected during transport: refrigerating circuit, electrical cabinet, chassis and
cabinet.
For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical (and safety) codes.
• Pay close attention to all warning and caution notices given in this manual.
• Supply the unit with a dedicated electrical line.
• Make install the unit by qualified personnel.
• Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage
shown on the nameplate.
• The installation of a double-pole switch, protected by 10 A fuses of the delayed type, upstream the electricity wall
socket, is recommended.
• WARNING!
The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3
minutes from a previous stop.
If necessary, get help
These instructions are all you need for most installation sites and maintenance conditions.
If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to
follow the instructions in this document.
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
ONLY QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring are completed or reconnected and checked, to ensure the grounding.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions
when wiring.
Improper connections and inadequate grounding can cause accidental injury and death.
• Ground the unit following local electrical codes.
• The Yellow/Green wire cannot be used for any connection different from the ground connection.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
• Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.
• Do not use multicore cable when wiring the power supply and control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the unit. Get a partner to help, and bend your knees when lifting to reduce strain
on your back. Sharp edges or thin aluminium fins on the unit can cut your fingers.
When installing
Make sure the wall is strong enough to hold the unit weight. It may be necessary to build a strong wooden or metal
frame to provide added support.
When wiring
WARNING
COOLING
OUTDOOR TEMPERATURE
43°C D.B.
ROOM TEMPERATURE
30°C D.B.
OUTDOOR TEMPERATURE
-10°C D.B.
ROOM TEMPERATURE
16°C D.B.
HEATING
OUTDOOR TEMPERATURE
24°C D.B.
ROOM TEMPERATURE
30°C D.B.
OUTDOOR TEMPERATURE
-15°C D.B.
INDOOR ROOM
16°C D.B.
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
OPERATING LIMITS
1 - GENERALITIES
OPERATING CONDITIONS
SPECIAL PRECAUTIONS
• Clean only with neutral detergents.
• Do not place objects on the unit.
• Do not pour liquids on the unit.
Wireless remote control unit
2.
Signaling LEDs and receiver
3.
Supply air deflector
4.
Air intake grille (removable)
5.
Air filter
6.
Electric cable with plug
7.
Air inlet hole with fan
8.
Air outlet hole
9.
Condensate discharge
10. Service cap for emergency condensate discharge
11. Operation button
2 - PRESENTATION
2
3
4
5
7
2.1 - DESCRIPTION OF THE PARTS
6
8
10
11
9
1
Strip of adhesive isolating tape (2pcs.)
2.
Air inlet and outlet external grids including
chains and kit for installing the grids (2+2 pcs.)
3.
Plastic sheet (2pcs.)
4.
Wall anchoring brackets (2pcs.)
5.
Operating and installation instructions
6.
Paper drilling template
7.
Remote control
8.
Condensate discharge pipe
2.2 - SIGNALING LEDs
2.3 - ACCESSORIES SUPPLIED WITH THE UNIT
1
2
3
4
5
6
7
8
1. Receiver : it receives signals transmitted from the
remote control.
2. COOLING LED: This LED lights up when the air
conditioner is operating in cooling mode.
3. HEATING LED: This LED lights up when the air
conditioner is operating in heating mode.
4. DEHUMIDIFICATION LED: This LED lights up when
the air conditioner is operating in dehumidification
mode.
5. STANDBY LED: This LED lights up when you switch
off the air conditioner with the remote control and it
indicates also the WIFI status during unit’s operation.
6. DIGITAL DISPLAY: it can display information such
as set temperature, ambient temperature, coil
temperature, status, fault code, etc.
7. WIFI: This LED lights up when the air conditioner is
operating in WIFI mode.
The OFF position does not disconnect the power. Use
the main power switch to turn off power completely.
WARNING
NOTES
● It is possible to set the air conditioner in order to switch OFF all LEDs, even during operation, by pressing the
LIGHT button on the remote control unit.
If the symbol on remote control display is on, the air conditioner display will be on; if the symbol is off,
the air conditioner display will be off.
● In case of troubleshooting the air conditioner diagnostic system activates the lamps accordingly, even if they
are set to OFF. See paragraph TROUBLESHOOTING for further details.
1
3
4
2
5
6
7