D-Link DIS-700G-28SW Quick Installation Manual

Text of the manual

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 1 DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots Quick Installation Guide This document outlines the quick installation of the DIS-700G-28SW series. Package Checklist Please verify that the box contains the following items: Item Quantity Rack-mounted Ethernet switch 1 Rack-mount bracket 2 Screws (for bracket) 6 ALM Terminal Block (2-pin) 1 Quick Installation Guide 1 RJ45 Ethernet Port Dust Cover 14 SFP Ethernet Port Dust Cover 2 Safety Instructions When a connector is removed during installation, testing, or servicing, or when an energized fiber is broken, a risk of ocular exposure to optical energy that may be potentially hazardous occurs, depending on the laser output power. The primary hazards of exposure to laser radiation from an optical-fiber communication system are:  Damage to the eye by accidental exposure to a beam emitted by a laser source.  Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber.

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 2 Model Layouts Front Access Models Front View DIS-700G-28SW Rear View DIS-700G-28SW Item Description 1 System Status Indicators (LED) 2 Port Status Indicators (LED) 3 Gigabit Copper RJ45 Ports 4 100/1000BaseSFP Slot (Port 25 & 26) 1000BaseSFP Slot (Port 27 to 28) 5 Terminal Block for Alarm Relay output 6 Grounding Screw 7 DC terminal block (dual input) 8 Console Port 9 Reset Button       

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 3 Dimensions (unit = mm)

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 4 Rack Mounting When mounting the switch, practice good safety habits. Relay rack mounting normally requires at least two people. 1. Obtain the tools required for the mounting hardware. 2. Attach the mounting brackets to the switch in one of two supported positions by using the screws in the accessory kit. 3. From the front of the relay rack, position the switch in preferred location. 4. Secure the switch in place with the provided screws on both left and right side of mounting bracket. Mounting Bracket Position 1 for Standard Mount Position 1 Position 2

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 5 Mounting Bracket Position 2 for Standard Mount Ground Connecting The switch must be properly grounded for optimum system performance. Alarm Relay Connecting The 30VDC/1A alarm relay output contacts are located in a 2P terminal block. The alarm relay contact is “Normal Open”, and it will be closed when detected any power failures. Power Connecting AC Power Connection If you use AC power, connect the AC power cord to the AC supply socket on the rear panel, and plug the cord into the external power source. The voltage must be 100 to 240 V (±10% tolerance). Warning: Ensure that all power sources to the chassis (power distribution panel) are turned off during the connection.

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 6 Ethernet Interface Connecting (RJ45 Ethernet) The switch provides two types of electrical (RJ45) and optical (mini-GBIC) interfaces. Connecting the Ethernet interface via RJ45:  To connect to a PC, use a straight-through or a cross-over Ethernet cable,  To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables. Ethernet Interface Connecting (Fiber, SFP) For a 1000 Mbps fiber port available, please use the mini-GBIC SFP. These accept plug in fiber transceivers that typically have an LC style connector. For a 100 Mbps fiber port (port 25 & 26 only) available, please prepare the LC connectors or SC connectors (with the use of an optional SC-to-LC adapter). They are available with multimode, single mode, long-haul or special-application transceivers. DANGER: Never attempt to view optical connectors that might be emitting laser energy. Do not power up the laser product without connecting the laser to the optical fiber and putting the cover in position, as laser outputs will emit infrared laser light at this point.

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 7 Console Connection The Console port is for local management by using a terminal emulator or a computer with terminal emulation software.  DB9 connector connect to computer COM port  Baud rate: 115200bps  8 data bits, 1 stop bit  None Priority  None flow control To connect the host PC to the console port, a RJ45 (male) connector-to-RS232 DB9 (female) connector cable is required. The RJ45 connector of the cable is connected to the CID port of DIS-700G-28SW; the DB9 connector of the cable is connected to the PC COM port. The pin assignment of the console cable is shown below: Connect & Login to DIS-700G-28SW 1. Connecting to DIS-700G-28SW Ethernet port (RJ45 Ethernet port). 2. Factory default IP: 192.0.2.1 3. Login with default account and password. Username: admin Password: admin

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 8 CLI Initialization & Configuration (Optional) 1. Connecting to DIS-700G-28SW Ethernet port (RJ45 Ethernet port). 2. Enter the command: telnet 192.0.2.1 3. Login with default account and password. Username: admin Password: admin 4. Change the IP address with commands listed below: CLI Command: SYSTEM RESET The Reset button is provided to reboot the system without the need to remove power. Under normal circumstances, you will not have to use it. However, or rare occasions, the DIS-700G-28SW may not respond; then you may need to push the Reset button. enable configure interface vlan 1 ip-address xxx.xxx.xxx.xxx netmask xxx.xxx.xxx.xxx exit

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 9 LED STATUS INDICATIONS LED Name Indicator /color Condition 1. System Status Indicators SYS On Green System is working normal Flash Green System booting, or database saving or remote download is in-progress Off System is not working or not have supply power P1 On Green P1 power line has power Flashing Green P1 is DC power and only one pair of power is input Off P1 power line disconnect or does not have supply power P2 On Green P2 power line has power Off P2 power line disconnect or does not have supply power Alarm On Red Alarm event occurs Off No alarm RR (Ring Role) On Green One of 3 Ring group is enabled and is Master role. Off Ring is slave role RS (Ring Status) On Green Ring fail happen and detected Off No ring fail detected 2. Port Status Indicators Copper port Link/Act (Port 1 to 24) On Green Ethernet link up but no traffic is detected Flashing Green Ethernet link up and there is traffic detected Off Ethernet link down Copper port Speed (Port 1 to 24) On Yellow A 1000Mbps connection is detected Off No link or a 10 Mbps,100Mbps connection is detected SFP port Link (Port 25 to 28) On Green Ethernet link up Flashing Green Ethernet link up and there is traffic detected Off Ethernet link down SFP Speed (100/1000M) (Port 25 to 28) On SFP port speed 1000Mbps Off SFP port speed 100Mbps or link down

DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots

Quick Installation Guide 10 Federal Communication Commission Interference Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Non-modification Statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Caution This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Innovation, Science and Economic Development Canada (ISED) Statement This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Japan Voluntary Control Council for Interference Statement この装置は、クラス A 情報技術装置です。 この装置を家庭環境で使用すると電波妨 害を引き起こすことがあります。 この場合には使用者が適切な対策を講ずるよう要求され ることがあります。 VCCI-A This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions. CE EMI Class A Warning This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. Ver 1.01 (EU) 2019/12/16 GP801280X-000

Other Switch Manuals