D-Link DIS-700G-28SW Quick Installation Manual
Text of the manual
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
1
DIS-700G-28SW
Industrial Layer 2+ Gigabit Managed
Switch with SFP slots
Quick Installation Guide
This document outlines the quick installation of the DIS-700G-28SW series.
Package Checklist
Please verify that the box contains the following items:
Item
Quantity
Rack-mounted Ethernet switch
1
Rack-mount bracket
2
Screws (for bracket)
6
ALM Terminal Block (2-pin)
1
Quick Installation Guide
1
RJ45 Ethernet Port Dust Cover
14
SFP Ethernet Port Dust Cover
2
Safety Instructions
When a connector is removed during installation, testing, or servicing, or when an energized fiber is
broken, a risk of ocular exposure to optical energy that may be potentially hazardous occurs,
depending on the laser output power.
The primary hazards of exposure to laser radiation from an optical-fiber communication system are:
Damage to the eye by accidental exposure to a beam emitted by a laser source.
Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber.
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
2
Model Layouts
Front Access Models
Front View
DIS-700G-28SW
Rear View
DIS-700G-28SW
Item Description
1 System Status Indicators (LED)
2 Port Status Indicators (LED)
3 Gigabit Copper RJ45 Ports
4 100/1000BaseSFP Slot (Port 25 & 26)
1000BaseSFP Slot (Port 27 to 28)
5 Terminal Block for Alarm Relay output
6 Grounding Screw
7 DC terminal block (dual input)
8 Console Port
9 Reset Button
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
3
Dimensions
(unit = mm)
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
4
Rack Mounting
When mounting the switch, practice good safety habits. Relay rack mounting normally requires at
least two people.
1. Obtain the tools required for the mounting hardware.
2. Attach the mounting brackets to the switch in one of two supported positions by using the
screws in the accessory kit.
3. From the front of the relay rack, position the switch in preferred location.
4. Secure the switch in place with the provided screws on both left and right side of mounting
bracket.
Mounting Bracket Position 1 for Standard Mount
Position 1
Position 2
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
5
Mounting Bracket Position 2 for Standard Mount
Ground Connecting
The switch must be properly grounded for optimum system performance.
Alarm Relay Connecting
The 30VDC/1A alarm relay output contacts are located in a 2P terminal block.
The alarm relay contact is “Normal Open”, and it will be closed when detected any power failures.
Power Connecting
AC Power Connection
If you use AC power, connect the AC power cord to the AC supply socket on the rear panel, and
plug the cord into the external power source. The voltage must be 100 to 240 V (±10% tolerance).
Warning: Ensure that all power sources to the chassis (power distribution panel) are turned off
during the connection.
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
6
Ethernet Interface Connecting (RJ45 Ethernet)
The switch provides two types of electrical (RJ45) and optical (mini-GBIC) interfaces.
Connecting the Ethernet interface via RJ45:
To connect to a PC, use a straight-through or a cross-over Ethernet cable,
To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP
(Shielded Twisted Pair) Ethernet cables.
Ethernet Interface Connecting (Fiber, SFP)
For a 1000 Mbps fiber port available, please use the mini-GBIC SFP. These accept plug in fiber
transceivers that typically have an LC style connector.
For a 100 Mbps fiber port (port 25 & 26 only) available, please prepare the LC connectors or SC
connectors (with the use of an optional SC-to-LC adapter).
They are available with multimode, single mode, long-haul or special-application transceivers.
DANGER:
Never attempt to view optical connectors that might be emitting laser energy.
Do not power up the laser product without connecting the laser to the optical fiber
and putting the cover in position, as laser outputs will emit infrared laser light at this
point.
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
7
Console Connection
The Console port is for local management by using a terminal emulator or a computer with terminal
emulation software.
DB9 connector connect to computer COM port
Baud rate: 115200bps
8 data bits, 1 stop bit
None Priority
None flow control
To connect the host PC to the console port, a RJ45 (male) connector-to-RS232 DB9 (female)
connector cable is required. The RJ45 connector of the cable is connected to the CID port of
DIS-700G-28SW; the DB9 connector of the cable is connected to the PC COM port. The pin
assignment of the console cable is shown below:
Connect & Login to DIS-700G-28SW
1.
Connecting to DIS-700G-28SW Ethernet port (RJ45 Ethernet port).
2.
Factory default IP: 192.0.2.1
3.
Login with default account and password.
Username: admin
Password: admin
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
8
CLI Initialization & Configuration (Optional)
1.
Connecting to DIS-700G-28SW Ethernet port (RJ45 Ethernet port).
2.
Enter the command: telnet 192.0.2.1
3.
Login with default account and password.
Username: admin
Password: admin
4.
Change the IP address with commands listed below:
CLI Command:
SYSTEM RESET
The Reset button is provided to reboot the system without the need to remove power. Under normal
circumstances, you will not have to use it. However, or rare occasions, the DIS-700G-28SW may not
respond; then you may need to push the Reset button.
enable
configure
interface vlan 1
ip-address xxx.xxx.xxx.xxx netmask xxx.xxx.xxx.xxx
exit
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
9
LED STATUS INDICATIONS
LED Name
Indicator /color
Condition
1. System Status Indicators
SYS
On Green
System is working normal
Flash Green
System booting, or database saving or remote download is
in-progress
Off
System is not working or not have supply power
P1
On Green
P1 power line has power
Flashing Green
P1 is DC power and only one pair of power is input
Off
P1 power line disconnect or does not have supply power
P2
On Green
P2 power line has power
Off
P2 power line disconnect or does not have supply power
Alarm
On Red
Alarm event occurs
Off
No alarm
RR (Ring Role)
On Green
One of 3 Ring group is enabled and is Master role.
Off
Ring is slave role
RS (Ring Status)
On Green
Ring fail happen and detected
Off
No ring fail detected
2. Port Status Indicators
Copper port Link/Act
(Port 1 to 24)
On Green
Ethernet link up but no traffic is detected
Flashing Green
Ethernet link up and there is traffic detected
Off
Ethernet link down
Copper port Speed
(Port 1 to 24)
On Yellow
A 1000Mbps connection is detected
Off
No link or a 10 Mbps,100Mbps connection is detected
SFP port Link
(Port 25 to 28)
On Green
Ethernet link up
Flashing Green
Ethernet link up and there is traffic detected
Off
Ethernet link down
SFP Speed
(100/1000M)
(Port 25 to 28)
On
SFP port speed 1000Mbps
Off
SFP port speed 100Mbps or link down
DIS-700G-28SW Industrial Layer 2+ Gigabit Managed Switch with SFP slots
Quick Installation Guide
10
Federal Communication Commission Interference Statement
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Non-modification Statement
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
Innovation, Science and Economic Development Canada (ISED) Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Japan Voluntary Control Council for Interference Statement
この装置は、クラス A 情報技術装置です。 この装置を家庭環境で使用すると電波妨
害を引き起こすことがあります。 この場合には使用者が適切な対策を講ずるよう要求され
ることがあります。
VCCI-A
This is a Class A product based on the standard of the Voluntary Control Council for
Interference (VCCI). If this equipment is used in a domestic environment, radio interference
may occur, in which case the user may be required to take corrective actions.
CE EMI Class A Warning
This equipment is compliant with Class A of CISPR 32. In a residential environment this
equipment may cause radio interference.
Ver 1.01 (EU) 2019/12/16 GP801280X-000