echoflex ELEDR Installation Manual

Specifications

Brand: echoflex
Category: Controller
Model: ELEDR (Installation Manual)
File Type: PDF
File Size: —
Pages: 8

Read Online

Read the echoflex ELEDR Installation Manual online using the built-in PDF viewer.

Text of the manual

ELEDR(H) Installation Guide

Installation Guide ELEDR(H) Power Load Controller • CAUTION - This equipment has more than one power supply connection point. To reduce the risk of electric shock, disconnect both the branch circuit- breakers or fuses and emergency power supplies before servicing. • CAUTION – Risk of Electric shock hazard. The controller uses high voltage and should only be in- stalled by qualified personnel in accordance with National Electrical Code and any local regulations. • CAUTION - To avoid electrical overload, total connected load should not exceed output rating. • This product is suitable for use in dry locations where the ambient temperature is -5°C to +50°C (23°F to 122°F). • Do not use outdoors. • Do not mount near gas or electric heaters • Equipment should be mounted in locations and at heights where it will not be subjected to SAVE THESE INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ELEDR(H) Installation Guide

tampering by unauthorized personnel. • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. • Do not use this equipment for other than its intended use. • Servicing should be performed by qualified ser- vice personnel. • Pollution Degree:2

ELEDR(H) Installation Guide

Overview This guide covers Echoflex Solutions Power Load Controller, model numbers ELEDR-AU 120-277 and ELEDRH-AU 240-347. Both models are equipped with a 902 MHz radio. The box contents includes the controller and installation guide. A programming guide with detailed features of the controller is available for download on www.echoflexsolutions.com. The ELEDR is designed to provide control of 120-277 VAC loads. The ELEDRH is designed to provide control of 240-347 VAC loads. The motor load rating for the power load controller is 1.5 HP @ 120VAC and 3.0 HP @ 277VAC. Simple Tap™ technology is included allowing installers and facility operators to manage configuration settings without any specialized tools. *see wiring diagram on page 5 for detailed output load ratings Preparing To Install The Controller The controller should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The controller is mounted using the conduit nipple for mounting the controller to electrical junction boxes or panels. You will require hand tools and supplies (not provided) to install the controller. • Screwdrivers, pliers, wire cutters, wire insulation stripping tool • Appropriately sized wire nuts • Small cable ties Scan the QR code to link to the programming guide

ELEDR(H) Installation Guide

Installing the Controller For best results mount the controller on the outside of the electrical box either directly at the electrical load or before the load in the circuit. Review these instructions completely before installing the controller. 1. Locate the circuit breaker panel and terminate power to the circuit. 2. Remove all face plates and other hardware from the junction box so you can access the high voltage wires. 3. Mount the controller to the exterior of the junction box or panel with the ½” threaded nipple. 4. Refer to the wiring diagram to connect the controller to line power, neutral and load wire. Use wire nuts on all connections and individually cap any bare wires (except orange antenna wire). 5. Restore power to the circuit. 6. If the controller was pre-commissioned you can use one of the pre- linked devices to test the controller operation. If the controller was not pre-commissioned by the factory, refer to the section of this guide titled Linking the First Switch. Use this switch to verify the controller functionality. Note: Always follow applicable NEC and local electrical code requirements when installing and powering the controller. i Note: The Micro USB port is for factory use only. Do not attach cables or accessories to this port The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Do not use this equipment for other than its intended use. Do not use outdoors. Electrical Terminations The controller has an external orange antenna wire. Do not cut, cap or connect this wire. Power to the controller is connected between the White (Neutral) and the Black Line power: ELEDR (120-277VAC) or ELEDRH (240-347VAC) Use only UL approved wire when making connections, see table below. Controller's Wire Details for ELEDR(H) Connection Color Specification Load Red 14AWG 600V Neutral White 14AWG 600V Line Black 14AWG 600V i

ELEDR(H) Installation Guide

Linking the First Switch Use this method to link the first switch. Use the learn button to link additional devices. 1. If the controller already has a sensor linked, press the TEACH button on the linked sensor and proceed to step 2 within 60 seconds. 2. Click the wireless switch paddle ON three times, OFF three times and ON three times sequentially within 5 seconds. The relay will toggle and the red POWER LED will begin a repeating blinking pattern to indicate the linked switch, see the section on LED blink codes. LEARN button The LEARN button is used to link switches or sensors to the controller. 1. Press the button marked LEARN for a half second. In link mode the LEARN LED will stay ON and the POWER LED will toggle every two seconds. 2. When linking a wall switch, press the switch paddle ON three times. If linking a sensor, press the sensor’s TEACH or LINK button, refer to the sensor’s documentation. The POWER LED will remain lit for four seconds while it links the new device. It will resume toggling allowing you to link another device up to a total of twenty devices. 3. To exit link mode, press and release the LEARN button on the controller. i Note: Linking a switch or sensor that is already linked to a channel, will remove or unlink it from the channel. i Note: Link mode will time out after no activity in thirty seconds. Power Load Controller Power LED Clear Button Learn Button Learn LED Antenna (orange) Do not cut or cap Black - Line, 120-277VAC OR 240-347VAC @ 50/60 Hz 500 mW max White - Neutral Red - Load, Switched Hot Max. Switching Load: (ELEDR) 20A@120-277VAC Electronic Ballast or LED Driver (ELEDRH) 20A@240-277VAC Electronic Ballast or LED Driver (ELEDRH)16A@347VAC Electronic Ballast or LED Driver Max. Impulse Voltage: 4000V Internal Relay: Type 1.C Motor load rating:1.5 HP @ 120VAC and 3.0 HP @ 277VAC. Load Neutral to others Red - To other loads Max load (ELEDR) 20A@120-277VAC Electronic Ballast or LED Driver (ELEDRH) 20A@240-277VAC Electronic Ballast or LED Driver (ELEDRH)16A@347VAC Electronic Ballast or LED Driver Wiring Diagram

ELEDR(H) Installation Guide

CLEAR button Using the CLEAR button can reload the controller to the factory pre- commissioned settings with linked devices or it can load the factory default parameters and remove all linked devices. • To return the controller to the factory pre-commissioned state, press the CLEAR button until the POWER and LEARN LEDs start blinking, approximately 5 seconds. Release the button and the POWER LED will begin blinking indicating the factory commissioned pre-linked devices. • To completely clear the controller returning it to factory default settings removing all linked devices, press the CLEAR button until the POWER and LEARN LEDs come on solid, about 15 seconds, then release. The POWER LED will stay ON solid indicating the factory default state. Power Load Controller Power LED Clear Button Learn Button Learn LED LED Driver Battery Backup Normal Hot Normal Neutral Load Control LED + LED - LED + LED - LED Emmitter Neutral Wiring Diagrams - For use in Emergency Fixtures (2 of 2) Wiring Diagrams - For use in Emergency Fixtures (1 of 2) Power Load Controller Power LED Clear Button Learn Button Learn LED Normal Hot Load Normal Neutral Emergency Hot Emergency Neutral Normal Control Sense Normal Emergency Load Neutral Hot UL924 Emergency Bypass Relay with appropriate voltage rating

ELEDR(H) Installation Guide

LED Blink Codes and Operation The tables below describe the LED activity and associated mode of the controller. If the controller was factory pre-commissioned, upon power up it will immediately begin blinking the POWER LED based on the type and count of linked devices. The type is indicated by long blinks followed by short blinks counting the number of devices linked. This pattern will repeat after a short pause See the ELEDR programming guide for more information: https://www.echoflexsolutions.com/files/8DC-5997-ELEDR-Programming-Guide.pdf The table below describes the number of LED blinks for each device type. RED POWER LED Blink Codes Factory Default ON Solid switch(es) 1 long blink followed by short blinks counting switches occupancy sensor(s) 2 long blinks followed by short blinks counting sensors photo sensor(s) 3 long blinks followed by 1 short blink counting a sensor central command 4 long blinks followed by short blinks counting devices demand response 5 long blinks followed by short blinks counting devices Operating Mode and LED Activity Mode LEARN LED : Red POWER LED: Red Relay/Light link mode ON toggle toggle storing ID ON ON 4 seconds ON 4 seconds clearing ID ON OFF 4 seconds OFF 4 seconds factory default Off (flash on power up) ON solid ON

ELEDR(H) Installation Guide

Listings & Regulatory Statements UL Listed Component Certified UL Standard 924 Certified UL Standard 60730 Certified CAN/CSA Std E60730 UL 2043 Plenum rated California Energy Commission Title 24 - CEC Washington State Energy Code - WSEC ANSI / ASHRAE / IES Standard 90.1 International Energy Conservation Code - IECC New York City Energy Conservation Code - NYCECC FCC Part 15.231 Contains FCC ID: SZV-STM300U IC RSS-210FCC Part 15.231 Contains FCC ID: SZV-STM300U The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation. Echoflex Solutions 38924 Queens Way, Unit #1, Squamish, BC, V8B 0K8, Canada n +1 778-733-0111 echoflexsolutions.com n 8DC-5985-1.0 n Document Part # 8189M21-5985-1 Rev A n 12/20 Copyright © 2020 Echoflex Solutions, Inc. Product information and specifications subject to change without notice.