Quantum QT-740 Operator's Manual

Text of the manual

Models QT-740 and QT-750

Manual Part No. DC30-006 Revision A Operator’s Manual Fixed/Elevating Float-Top Radiographic Tables

Copyright © 2000 QMI

This manual is copyrighted and all rights are reserved. No portion of this document may be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Quantum Medical Imaging, LLC. Made in U.S.A. Quantum Medical Imaging, LLC 2905 Veterans Memorial Highway Ronkonkoma, New York 11779 USA Phone: (631) 567-5800 Fax: (631) 567-5074

Models QT-740 & QT-750 - Operator’s Manual

i REVISION DATE TYPE OF MODIFICATION A 11/01/00 Initial Release. Page Number Rev Page Number Rev Page Number Rev i - iv A 1 - 30 A

Models QT-740 & QT-750 - Operator’s Manual

THIS PAGE INTENTIONALLY LEFT BLANK

Table of Contents

Models QT-740 & QT-750 - Operator’s Manual iii Table of Contents Chapter 1, Safety Notices 1 Chapter 2, General Information 7 Chapter 3, Operation 11 Chapter 4, User Maintenance 21 Chapter 5, Warranty Information 25

Table of Contents

iv Models QT-740 & QT-750 - Operator’s Manual THIS PAGE INTENTIONALLY LEFT BLANK

Chapter 1 Safety Notices

Models QT-740 & QT-750 - Operator’s Manual 3 WARNING Quantum Medical Imaging, LLC disclaims all responsibility from any injury resulting from improper application of this equipment. This equipment is sold to be used exclusively under the prescribed direc- tion of a person who is licensed by law to operate equipment of this nature. This equipment must be used in accordance with all safety procedures described in this manual and must not be used for purposes other than those described herein. Quantum Medical Imaging, LLC cannot assume responsibility for any mal- functioning of this equipment resulting from improper operation, mainte- nance, or repair, or from damage or modification of its components. Failure to observe these warnings may cause serious injuries. X-RAY PROTECTION X-rays are hazardous to both patient and operator unless established safe exposure factors and operating instructions are observed. It is important that everyone having anything to do with x-radiation be properly trained and fully acquainted with the recommendations of the National Council on Radiation Protection and Measurements as published in NCRP Reports available from NCRP Publications, 7910 Woodmont Ave- nue, Suite 800, Bethesda, Maryland 20814-3095 (www.ncrp.com), and of the International Commission on Radiological Protection (www.icrp.org), and take adequate steps to protect against injury. X-ray equipment may cause injury if used improperly. The instructions con- tained in this manual must be read and followed when operating this unit. Personal radiation monitoring and protective devices are available. You are urged to use them to protect against unnecessary x-ray exposure.

Chapter 1 Safety Notices

4 Models QT-740 & QT-750 - Operator’s Manual REGULATORY COMPLIANCE This certified Quantum Medical Imaging, LLC medical device has been designed, manufactured, and calibrated to comply with governing Federal Regulations 21 CFR Subchapter J and the performance standards attendant thereto. Upon installation, all certified products require the filing of Form FD-2579 "Report of Assembly of a Diag- nostic X-ray System" by the assembler (i.e., the installer) with the appropriate agen- cies; the "Installation Quality Assurance Checklist" must also be completed and properly distributed upon installation. A copy of each form (pink copy) is provided to the user. The installation report is completed by the installer and returned to Quan- tum Medical Imaging, LLC. Those responsible for the planning of x-ray equipment installations must be thor- oughly familiar and comply completely with NCRP Report No. 49, "Structural Shielding Design and Evaluation for Medical Use of X-Rays and Gamma Rays of Energies up to 10 MeV", as revised or replaced in the future. Those authorized to operate, test, par- ticipate in or supervise the operation of the equipment must be thoroughly familiar and comply completely with the currently established safe exposure factors and pro- cedures described in publications such as Subchapter J of Title 21 of the Code of Fed- eral Regulations, "Diagnostic X-Ray Systems and Their Major Components," and NCRP Report No. 102, “Medical X-Ray, Electron Beam and Gamma Ray Protection for Ener- gies Up to 50 MeV—Equipment Design and Use” as revised or replaced in the future. Scheduled maintenance is essential to the assurance of continued integrity of this equipment with respect to regulatory compliance. The continuance of certified perfor- mance to the regulatory standard is incumbent upon the user's diligent conformance to recommended maintenance instructions. This product has been classified as Class I, Type B by Underwriters Laboratories, Inc. Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or with nitrous oxide.

Chapter 1 Safety Notices

Models QT-740 & QT-750 - Operator’s Manual 5 The following symbols may be used for marking on this equipment or equipment doc- umentation: Earth (ground) Type B Equipment Protective Earth (ground) Attention, consult accompanying documents Dangerous Voltage Enable tabletop float (releases transverse and longitudinal locks) Enable Tabletop Up Motion Enable Tabletop Down Motion

Chapter 1 Safety Notices

6 Models QT-740 & QT-750 - Operator’s Manual THIS PAGE INTENTIONALLY LEFT BLANK

Chapter 2 General Information

Models QT-740 & QT-750 - Operator’s Manual 9 OVERVIEW This manual provides information for installing, operating, and maintaining Quantum Medical Imaging’s Fixed (Model QT-740) and Elevating (Model QT-750) Radiographic Tables (hereinafter referred to as the radiographic table). It is imperative that all safety procedures described in this manual be strictly adhered to in order to ensure the safety of both patient and user. The key features of the Model QT-740 and QT-750 radiographic tables are as follows: • Large Tabletop area (85 inches long x 34 inches wide) provides ample examination platform • Four-way floating tabletop permits 36 inches of longitudinal travel and 10 inches of lateral travel for full radiographic coverage • Foot pedal controls for table float-top motions (foot pedal inhibit switch deactivates foot pedals to prevent inadvertent tabletop motion) • Push button FLOAT control provided for operator convienence • Small patient-to-film plane distance provides improved radiography with minimal magnification • Accepts all types of image receptors (buckies, grids, and stationary grid cabinets) • Patient handgrips are standard accessory • AC line cord, fitted with hospital-grade plug, plugs into a 115VAC, 50/60 Hz receptacle (also configurable for 220 VAC, 50/60 Hz power input) • The Image Receptor Cabinet is equipped with electric locks ensuring precise film receptor alignment In addition, the Model QT-750 provides: • Heavy-duty lift mechanism allows for patient loads of up to 650 lbs. (weight must be centered over table base) • Variable height tabletop, lowers to 21 inches and raises to 32.5 inches (11.5 inches total vertical travel) • Foot pedal controls for table up/down motions • Collision sensors disable tabletop down motion in the event an obstruction is detected below tabletop INTENDED USE The Fixed Float-top (Model QT-740) and Elevating Float-top (Model QT-750) Radiographic Tables are intended for use as a patient support device during the performance of radiographic examinations. NOTE The user should read this man- ual in its en- tirety prior to using this equip- ment. It should be kept in a location near the equipment and readily ac- cessible to the those that oper- ate it.

Chapter 2 General Information

10 Models QT-740 & QT-750 - Operator’s Manual MAIN COMPONENTS See Figure 1. The radiographic table contains: 1 Tabletop 2 Emergency Shut-off Switch (Model QT-750 only) 3 Foot Pedal/FLOAT Push Button Inhibit Switch 4 Base 5 Foot Pedal(s) - Float (Model QT-740) Float, Up and Down (Model QT-750) 6 Float Push Button Switch 7 Patient Handgrips 8 Image Receptor Lock Release Switch Figure 1. Radiographic Table Main Components 4 3 2 5 8 7 6 1

Chapter 3 Operation

Models QT-740 & QT-750 - Operator’s Manual 13 OVERVIEW To provide precise patient positioning, Model QT-740 and QT-750 radiographic tables feature a tabletop that "floats" in four directions; transversely (forward and backward) and longitudinally (left and right). Model QT-750 has the additional capability of tabletop elevation (i.e., the tabletop can be raised and lowered to facilitate patient transfer on and off the table). TABLE CONTROLS WARNING! All movable assemblies and parts of this equipment must be operated with reasonable care. Manufacturer’s equipment recommenda- tions described in this manual must be observed. WARNING! To avoid damage to the table, any load on table top should be distributed as evenly as possible over the support surface. Do not seat patient at extreme ends of tabletop when table- top is not centered. Patients weighing more than approximately 300 lbs. (136 kg) should only be transferred on or off the table from front side - in the center. WARNING! Do not allow patient to place his/her hands along the side or below the table rail. Injury to the patient’s hands and/or fingers is possible. Figure 2. Areas Indicated to Keep Hands/Fingers Away From

Chapter 3 Operation

14 Models QT-740 & QT-750 - Operator’s Manual TABLETOP FLOAT MOTION (ALL MODELS) Models QT-740 and QT-750 both feature a "floating" tabletop. With the "float- top" function activated, both transverse and longitudinal positioning of the patient is enabled. To operate the float-top function, proceed as follows: WARNING! When transferring a patient on or off the tabletop, always make sure the tabletop is locked. If necessary, the Foot Pedal Disable Switch may be activated to prevent unintended activation of the FLOAT foot pedal control. Figure 3. Patient Positioned on Tabletop FLOAT FOOT PEDAL Figure 4. Model QT-740 FLOAT Foot Pedal Control

Chapter 3 Operation

Models QT-740 & QT-750 - Operator’s Manual 15 1. Position the patient on the table with his or her hands situated along the side of their body, or with the hands grasping the patient handles (see Figure 3). Be sure that the hands remain above the tabletop. 2. Press the FLOAT foot pedal (see Figures 4 and 5) to enable transverse and/or longitudinal motion of the tabletop. (When the foot pedal is pressed, it releases electromagnets (locks) that prevent transverse and longitudinal tabletop motion.) 3. Releasing the FLOAT foot pedal immediately activates tabletop locks, inhibit- ing transverse and longitudinal tabletop motion. ELEVATING MOTION (MODEL QT-750 ONLY) On Model QT-750 radiographic tables, the elevation function allows the tabletop to be lowered down to as low as 21 inches (533.4 mm) from floor, up to a work- ing height of 32.5 inches (825.5 mm). To operate the tabletop elevation function, proceed as follows: WARNING! For safety purposes, an Emergency Stop Switch (see Figure 6) immediately removes power from the tabletop up/down motor when activated. Rotating the Emergency Stop Switch knob 1/4-turn counterclockwise releases the Emergency Stop Switch and restores power. Figure 5. Model QT-750 - Foot Pedal Controls FLOAT FOOT PEDALS UP PEDAL DOWN PEDAL

Chapter 3 Operation

16 Models QT-740 & QT-750 - Operator’s Manual . LOWERING THE TABLETOP 1. It is recommended that the tabletop be centered before lowering it (refer to Tabletop Float Motion operation in preceding para- graph). 2. Press the DOWN foot pedal (see Figure 5) to lower the tabletop to the desired height. 3. Transfer patient onto tabletop. 4. Ensure patient is positioned with his or her hands situated along the side of their body, or with the hands grasping the patient handles (see Figure 3). Be sure patient’s hands remain above the tabletop. Note: As it is lowered, the speed at which the tabletop travels will gradually be reduced until the tabletop reaches the lowest point of travel for optimal patient comfort. RAISING THE TABLETOP 1. Press the UP foot pedal (see Figure 5) to raise the tabletop to the desired height. 2. Proceed with examination. EMERGENCY STOP SWITCH FOOT PEDAL/ FLOAT PUSH BUTTON DISABLE SWITCH Figure 6. Emergency Stop and Pedal Disable Switch Locations NOTE Model QT-750 tables are equipped with Obstruction Sensors, which detect the presence of an obstruction below the tabletop when the tabletop is being driven downward. This feature is only designed to avoid dam- age to the table and is not intended as a safeguard against per- sonal injury.

Chapter 3 Operation

Models QT-740 & QT-750 - Operator’s Manual 17 FOOT PEDAL/FLOAT PUSH BUTTON DISABLE SWITCH To prevent accidental activation of the foot pedal controls (i.e., FLOAT foot pedal on Model QT-740 and FLOAT, UP, and DOWN foot pedals on Model QT-750) and the FLOAT push button, a Foot Pedal Disable Switch is provided. This switch is located below the front table rail on the left end of the table (see Figure 6). Pressing the switch until the switch light is illuminated disables all foot pedal func- tions (and the FLOAT push button switch). When the Foot Pedal Disable Switch light is not illuminated, the foot pedals and FLOAT push button switch are fully operational. IMAGE RECEPTOR CABINET LOCK The Image Receptor Cabinet rides on four linear ball-bearings mounted to adjust- able brackets attached to either side of the cabinet (see Figure 7). These bear- ings travel on the hardened and polished steel shafts of the Receptor Cabinet Carriage. An electromagnet on the underside of the housing "locks" the cabinet into place until the LOCK RELEASE switch is depressed, thereby releasing the magnet’s hold and allowing free movement of the cabinet. CASSETTE TRAY OPERATION The radiographic table is equipped with either a Midwest or Poersch cassette tray, depending on the system ordered. The following paragraphs describe the operat- ing instructions for each. Additional information is contained in the cassette tray manufacturer’s documentation, which is provided with the table. LOCK RELEASE SWITCH Figure 7. Image Receptor Cabinet LOCK RELEASE Switch

Chapter 3 Operation

18 Models QT-740 & QT-750 - Operator’s Manual Loading Cassette Tray (Midwest Type) To load a film cassette into a "Midwest" type cassette tray, proceed as fol- lows: 1. Float the table top fully back. 2. Pull cassette tray from receptor using tray handle (see Figure 8). 3. Pull back on front cassette grip to open both grips. 4. Position slide guides ("L" brackets seated in channels) to cassette size using indicators on cassette tray (press center brass button to allow movement). 5. Insert cassette into tray (back end first). 6. Lock cassette into tray. 7. Push front grip against cassette. 8. While pushing front grip against cassette, turn cassette lock han- dle to lock position. 9. Push tray into receptor. The cassette is now in exposure position. CASSETTE GRIP TRAY HANDLE SLIDE GUIDES LOCK HANDLE Figure 8. Midwest Cassette Film Tray

Chapter 3 Operation

Models QT-740 & QT-750 - Operator’s Manual 19 Loading Cassette Tray (Poersch Type) To load a film cassette into a "Poersch" type cassette tray, proceed as fol- lows: 1. Float the table top fully back. 2. Pull cassette tray from receptor using tray handle (see Figure 9). 3. Place thumb under lip of clamp handle. Lift handle to release. 4. Grasp handle and slide clamp back for inserting cassette. 5. Insert cassette into tray (back end first). Center it using center- ing label. 6. Slide clamp forward pushing clamp firmly against cassette. 7. While pushing clamp against cassette, press clamp handle down. TRAY HANDLE CLAMP HANDLE Figure 9. Poersch Cassette Film Tray

Chapter 3 Operation

20 Models QT-740 & QT-750 - Operator’s Manual THIS PAGE INTENTIONALLY LEFT BLANK

Chapter 4 User Maintenance

Models QT-740 & QT-750 - Operator’s Manual 23 OVERVIEW This chapter is designed to assist the system user in maintaining the smooth opera- tion of the table. The user is responsible for performing certain routine maintenance and inspection procedures. Aside from routine maintenance, any abnormal noise, vibration, or unusual performance should be investigated by a qualified service repre- sentative. Preventive maintenance or any repair service should be performed only by qualified service personnel. WARNING! Failure to follow manufacturer’s or service personnel’s recommendations may result in serious injury. USER MAINTENANCE User maintenance consists of the following activities, which should be performed on a daily basis: • Visually inspect the table for wear and cleanliness • Clean the tabletop, cassette tray, and exterior painted surfaces of the table Cleaning The system user is responsible for the basic cleanliness of the equipment. On a regular basis, the table surface should be wiped clean. Painted metal sur- faces should be cleaned using a clean cloth slightly moistened in warm soapy water (use mild soap). Wipe with a clean wet cloth, then dry. Never use abrasive polish on this equipment. WARNING! Always disconnect the equipment from the main power supply prior to any cleaning. On 115 VAC systems, the power supply cord is the power disconnect device. On 230 VAC systems, the power disconnect device is either the genera- tor circuit breaker (when generator is power source) or the main disconnect (or power cable) on systems wired directly to facility power. To remove the cassette tray from the Receptor Cabinet for cleaning, proceed as follows: Midwest Trays 1. Float the table top fully back. 2. Pull the cassette tray out by the handle until it stops. 3. Grasp both sides of the tray with your right hand placed near the table and your left hand towards the tray front.

Chapter 4 User Maintenance

24 Models QT-740 & QT-750 - Operator’s Manual 4. Locate the spring-loaded lever on the right side of the tray bottom. A spring-loaded plate covers this hole. Press the lever with your right index finger, lift the cassette tray up slightly and pull the tray away from the Receptor Cabinet. Poersch Trays 1. Float the table top fully back. 2. Pull the cassette tray out by the handle until it stops. 3. Grasp the left side of the tray with your left hand. 4. Locate the square block at the back right side of the cassette tray. A spring-loaded plate is on the front side of the block. While pressing the plate, pull the tray out from the Receptor Cabinet.

Models QT-740 & QT-750 - Operator’s Manual

27 Chapter 5 Warranty Information WARRANTY STATEMENT Quantum Medical Imaging, LLC (herein known as “QMI”) warrants to buyer that any new product manufactured by QMI will be free from defects in material and manufac- turing and conform substantially to applicable specifications in effect on the date of shipment when subjected to normal, proper and intended usage by properly trained personnel. All QMI products shall be warranted for a period of 12 months from the time of origi- nal installation, the date of which will be determined by a completed, returned war- ranty card, which must be returned within 30 days of system installation. In no case shall the warranty exceed 15 months from the date of shipment. If the warranty card is not returned to QMI, then the warranty shall take effect 12 months from the date of shipment by Quantum Medical Imaging. Buyers should complete one (1) form per system or component, if items are ordered separately. WARRANTY CARD

Models QT-740 & QT-750 - Operator’s Manual

Chapter 5 Warranty Information WARRANTY STATEMENT (Continued) Fill in and mail Warranty Card promptly to: Quantum Medical Imaging, LLC 2905 Veterans Memorial Highway Ronkonkoma, N.Y. 11779 USA Any component furnished without charge to Buyer/Dealer during the warranty period to correct a warranty failure shall be warranted only to the extent of the unexpired term of the warranty of the original product. This warranty extends only to the origi- nal purchase and is not transferable unless authorized in writing by Quantum Medical Imaging. Products manufactured by parties other than QMI, where QMI acts solely as distribu- tor or reseller, will carry their respective manufacturers’ warranties. Warranty consideration will be given only for defective QMI products properly returned to the factory in accordance with QMI’s warranty return procedure (refer to Dealer Price Book or contact Quantum Medical Imaging, LLC. customer service). WARRANTY EXCLUSIONS The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, express, implied or statutory. NO IMPLIED WARRANTY OF MERCHANT- ABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. QMI Warranty is exclusive of: 1) Failure of Buyer/Dealer to prepare the site or provide power requirements or oper- ating environmental conditions in compliance with any applicable instructions or recommendations of Quantum Medical Imaging. 2) Failure of Buyer/Dealer to provide the proper incoming power required to support the equipment in accordance with the recommendation of QMI. 3) Any modification of product performed by a party other than Quantum Medical Imaging. 4) Combining incompatible products. 5) Improper or extraordinary use of the Product, improper maintenance of the Prod- uct, or failure to comply with any applicable instructions or recommendations of Quantum Medical Imaging. 6) Misuse, tampering or, negligent storage/handling of the Product by Buyer, its employees, agents or contractors. 7) Fuses and other items deemed by QMI to be expendable. 8) Acts of God, acts of civil or military authority, fires, floods, power failure or electri- cal power surges, strikes or other labor disturbances, war riots or other causes beyond the reasonable control of Quantum Medical Imaging. 9) Installation, troubleshooting or repair service are not included in this warranty. Technical service and maintenance is the responsibility of the dealer selling the equipment. 10) The Manufacturer is relieved of any responsibility for damage during shipment after the freight carrier transports the unit for delivery.

Models QT-740 & QT-750 - Operator’s Manual

29 Chapter 5 Warranty Information BUYER’S REMEDIES If Quantum Medical Imaging determines that any Product fails to meet any warranty during the applicable warranty periods, Quantum Medical Imaging shall correct any such failure as follows: A) By repairing, adjusting, or replacing any defective or non-conforming Parts or Products. B) By making available any necessary repaired or replacement parts or assemblies. Quantum Medical Imaging shall have the option to furnish either new or exchange replacement parts or assemblies. All returned parts shall become the property of Quantum Medical Imaging. The preceding Paragraphs set forth Buyer’s Remedies and Quantum Medical Imag- ing’s sole liability for claims based upon failure of the product to meet any warranty, whether the claim is on contract, warranty, Tort (including negligence and strict liabil- ity) or otherwise, and however instituted. And upon the expiration of the applicable warranty period, all such liability shall terminate. In no event shall Quantum Medical Imaging be liable for special or consequential damages. The warranties and remedies available to the buyer are conditioned upon all claims under this warranty being made in accordance with the aforementioned warranty statement.

Models QT-740 & QT-750 - Operator’s Manual

Chapter 5 Warranty Information THIS PAGE INTENTIONALLY LEFT BLANK