2-Zone Hose Faucet Timer

Model No.ITV201P WEB: www.rainpointus.com Email:[email protected] Free Hotline (US): 833 3815659

PLEASE ACTIVATE THE VALVE BEFORE USE IF YOU ARE USING IT

FOR THE FIRST TIME OR AFTER A PERIOD OF IDLENESS TO ENSURE YOU CAN USE IT PROPERLY: 1. TURN THE TIMER DIAL TO ON AND HOLD THE OK BUTTON FOR 3-5 SEC TO ENTER MANUAL WATERING MODE. 2. RE-PRESS THE ZONE BUTTON 2 TIMES TO SELECT 2 ZONES 3. AFTER HEARING 2 "CLICKING" SOUND, TURN THE DIAL TO OFF TO CLOSE THE MANUAL FUNCTION. 4. REPEAT STEPS1-3 FOR 3-5 TIMES. (EXPLANATION: IN MOST CASES THE VALVE IS ACTIVATED, BUT DUE TO EXTERNAL FORCES OR THE ENVIRONMENT DURING STORAGE AND TRANSPORTATION BY A VARIETY OF FACTORS, THE VALVE MAY APPEAR TO CLOSE ON ITS OWN, THEN IT NEEDS TO BE ACTIVATED MANUALLY) FOR ANY PROBLEMS DURING USE, PLEASE GET SUPPORT AS FOLLOWS: WEB: www.rainpointus.com EMAIL:[email protected] FREE HOTLINE (US): 833 3815659

Select Zone Left or Zone Right to be programmed

FILTER DIAL DELAY/+ BUTTON ZONE BUTTON - BUTTON P BUTTON OK/MANUAL BUTTON HOSE TAP CONNECTION BIG LCD SCREEN

3 C - 50 C (37 F - 122 F)

Water Duration 1min - 3h59min Water Frequency every 2 days to every 6 days or any day from Monday to Sunday Waterproof and Dustproof IP54 Max Flow Rate 35L/Min Thread Type For tap 3/4 or 1 with BSP or NH thread Powered By 2*AAA Alkaline Batteries (Excluded) Battery Life Approx 1 year Working Temperature Operating Water Pressure 0.5 - 8bar (7-116 psi)

1) First select ZONE L, complete the settings for ZONE L according to steps

1-4 below, then turn the dial to "ON" to save the changes. 2) Then press ZONE to select ZONE R, repeat the following steps 2-4 again, and finally turn the dial to "ON" to save the changes. After completing the settings of each dial item, please turn the dial to save and go to the next dial item. If you continue to press the OK button at this time, you will re-enter the setting of the dial item.

1. Turn dial to START TIME.

2. Using the "+" and "-" button to set time to start watering. 3. Using "OK" button to switch time between hours and minutes. 4. Press "P" to switch plan between P1, P2 and P3. 5. Press "ZONE" button to switch outlet between ZONE Left and ZONE Right . 6. Turn dial to save changes. 1. Turn dial to HOW LONG. 2. Using the "+" and "-" button to set the time of watering duration from 1 minute to 3 hours 59 minutes. 3. Using "OK" button to switch time between hours and minutes. 4. Press "P" to switch plan between P1, P2 and P3. 5. Press "ZONE" button to switch outlet between ZONE Left and ZONE Right . 6. Turn dial to save changes.

1.Turn the dial to HOW OFTEN.

2.There are 2 setting modes for watering frequency. 1)Weekday Mode : Monday to Sunday. (Watering plans will run every Sunday, Wednesday, Thursday and Friday) a. Press "+" button to select the day of the week, press "OK" to confirm. b. means the "Day" has been selected. Pressing "OK" again can cancel the selection. c. Turn dial to confirm the changes. (Watering plans will run every day) If you want to run the watering schedule every day, please select every day from Monday to Sunday. After you have finally selected the days to be watered, please do not press the OK button to confirm, please turn the dial directly to confirm. Otherwise the cursor will flashing on next day or enter the “Every 2/3/4/5/6 Days Mode”

If there are no problems, please turn dial to ON to allow your timer to water according

to the programmed time, zone, duration and frequency. 1) With the dial in the "ON" position, press the "DELAY/+" button for 3-5s to start the delay watering function. 2) In Delay Mode, you can find the selection of 24H flashing on the screen. Press "+" and "-" to select delay time from 24H, 48H and 72H. 3) Press "OK" button to confirm , then the screen will start countdown. The plan will resume when the countdown ends. 4) To remove rain delay, you need to hold the “DELAY/+” button for 3-5s again to resume your watering schedules. When the selection is flashing, if there is no action or operation for 5 sec, the Rain Delay Mode will automatically start based on the time you stay.

1) When the selection is flashing, if there is no action or operation for 5 sec, the

Manual Mode will automatically start based on the time you stay. 2) There may be a slight delay between the time the manual button is pressed and when watering begins. 4) Press "OK" button to confirm and start the manual watering. 5) To stop manual watering, turn the dial to OFF and then back to ON, or hold the "OK/MANUAL" button for 3-5s again to resume your programmed watering schedule. 3) Use the "+" and "-" button to select watering time, from 1 min to 59 mins. (The default manual watering time is 10 minutes.) R L LEFT R Zone L are shown by default. RIGHT

If you want to use only ZONE L and close ZONE

R, please set it up as follows. 1) Turn the dial to "Start Time" and select ZONE R. 2) Press the "P" button to switch Plan, then press the "+" or "-" button until the screen displays OFF bonoth P1, P2 and P3. 3) Turn the dial to "ON" to save the changes. If you only want to use ZONE R and close ZONE L, the same applies. Note: When the low battery indicator appears on display, the valve will close automatically to avoid leakage. Please replace the battery in time in case of interrupting the normal operation.

1. No filter or not be

placed horizontally 2. The faucet is not the standard 3/4" The water inlet leakage 1. Add filter and make sure it' s placed horizontally in the inlet. 2. Make sure the faucet is a 3/4" faucet. 3. Strengthen it with raw rubber wrap. 1. Long-term storage and transportation make the valve inactive 2. Valve blockage The water won't stop/flow out Step1. Keep the tap turned off and turn the timer dial to ON; Step2. Select the zone you want to fix (ZONE L or ZONE R) and run manual watering for 3-5s and stop it ; Step3. Repeat the Step 2 for 5 to 7 times; Step4. Try using it normally. 1. The dial/valve is stuck 1. Mixed use of old and new batteries 2. Used the carbon batteries or rechargeable batteries Dial or button problems Short battery life 1.Same procedure as above. 2.Turn the dial to the OFF to check if the valve can be closed. 1. Use brand new alkaline batteries. 2. Rechargeable batteries and carbon batteries have a short and unstable battery life, please use the alkaline batteries instead of them. 2. Accidentally holding the OK button while inserts the batteries

1. Filter blockage

2. Inlet pressure not sufficient to support watering Low water pressure 1. Check if the filter is clogged, if so, clean or replace the filter. 2. Make sure the timer is installed properly and not cross-threaded. 3. Installation of a booster pump or other auxiliary equipment of increasing pressure, the product itself does not have a pressurization function. If you have further questions, visit the following link: https://rainpointus.com/downloads/faq If it doesn't work and you want to return or replace it, please contact us for support during the warranty period. Hotline (US):1-833-381-5659 E-mail: [email protected]

1) Intended for outdoor use only, put in the sheltered outdoor will prolong the the

product lifetime. 2) Using tools to tighten your timer is too tight, easy to damage. to avoid damaging the timer, please tighten it with your hand instead of a tool. 3) Please ensure that the filter is placed horizontally in the top connector before installation to prevent leakage, add a filter and thread seal tape if necessary. 4) Mesh filter prevents dirt particles, prolonging the life of the hose timer. Clean filter regularly and replace if worn. 5) When the power is low, please replace the batteries in time to avoid the interruption of the normal operation; when replacing the batteries, please make sure that the battery compartment is dry. 6) When not in use, remove batteries, drain and store indoors to away from freezing. 7) Do not use the timer which it's more than 120°F(50℃), or less than 38°F(3℃). 8) Do not subject the product to extreme force and shock. 9) Severe electrical shock could result if water is sprayed into outlets or sources of electrical current. Never immerse the product in water.

Need Help? Call 1-833 3815659

Or email to [email protected] Scan the QR code to visit the setup video