Service Manual Traverse Switch • 3EN120401 Rev. 7

2 www.liko.com l www.hill-rom.com Spare part statement Liko AB will as manufacturer of stationary & mobile lifts keep spare parts available for 10 years after the last manufacturing date of the product. Spare parts are available in the spare parts list or in the Service Manual for each model of lift. Components (manufacturing parts) are not available after last manufacturing date. Repairs and maintenance may only be performed by personnel authorized by Hill-Rom and using original Liko™ spare parts. For information regarding Service and Maintenance education, contact your Hill-Rom representative. For contact information please visit our website: www.hill-rom.com l www.liko.com In this document, this warning symbol indicates that special care should be taken. If instructions are not followed there is a risk of serious injury to patient or caregiver.

Service Manual Traverse Switch • 3EN120401 Rev. 7

3 www.liko.com l www.hill-rom.com Page 1.0 Technical Data ................................................................4 � 2.0� Troubleshooting .............................................................5 � 3.0�� Spare�Parts�Assembly�information ................................6 4.0 Spare Parts List ..............................................................7 � 5.0�� Periodic�Inspection�Information ....................................8 6.0 Product Changes ............................................................9 Table of Contents Traverse Switch

Service Manual Traverse Switch • 3EN120401 Rev. 7

4 www.liko.com l www.hill-rom.com 1.0 Technical Data, Traverse Switch 2010-04-21, llasaba 2 (10) Technical Data © Copyright Liko AB 2012-09 Inspection and Maintenance When necessary, clean the product with a moist cloth using common surface cleaners or disinfectants. NOTE! Do not use cleaning agents that contain phenol or chlorine, since these can damage aluminium and plastic materials. Service Likos transfer system should be periodically inspected at least once a year. Periodic inspection, repair and maintenance should be performed only in accordance with the Liko Service Manual and by personnel authorized by Liko/HillRom and using original Liko spare parts. Service Agreement Liko/HillRom offers the opportunity to enter into service contracts for the maintenance and periodic inspection of your Liko products. Expected Service Life The product has an expected life time of 10 years when correctly handled, serviced and inspected in accordance with Liko’s instructions. Transport and Storage The environment in which the product is transported and stored should have a temperature of 10–40 ˚C and a relative humidity of 30–75 %. The air pressure should be 700–1060 hPa. Recycling For instructions on how to recycle your Liko product, please visit the Liko website: www.liko.com. Product Changes Liko’s products undergo continous development, which is why we reserve the right to make product changes without prior notice. Contact your Liko/HillRom representative for advice and information about product upgrades. Design and Quality by Liko in Sweden Liko is quality-certified in accordance with ISO 9001 and its equivalent for the medical device industry, ISO 13485. Liko is also certified in accordance with environmental standard ISO 14001. The device is intended for indoor use. Type B, in accordance with the electrical shock protection class. Class II equipment. Prod. No. 3124604 (only in combination with Liko H-70 rail) Dimensions: A: 490 mm / 19.3 inch. B: 160 mm / 6.3 inch. C: 92 mm / 3.6 inch. Built-in dimension, H: 92 mm / 3.6 inch. Weight: 3.5 kg / 7.7 Ibs. Max. load: 250 kg / 550 Ibs. Material: Aluminium, Steel and plastic. Protection class: IP X1 www.liko.com Manufacturer: Liko AB Nedre vägen 100 SE-975 92 Luleå Sweden i f @lik

Service Manual Traverse Switch • 3EN120401 Rev. 7

5 www.liko.com l www.hill-rom.com 2.0 Troubleshooting, Traverse Switch The switch doesn't work. 1. Check mains power supply. 2. Ensure that the cable is properly connected to the power supply. 3. Check that hand control is firmly connected. 4. If the switch still does not work correctly contact Hill-Rom. The switch stops in close or 1. Check cables to power supply. open position. 2. Check mains power supply. 3. If the switch still does not work correctly contact Hill-Rom. If the switch makes an unusual Contact Hill-Rom. sound.

Service Manual Traverse Switch • 3EN120401 Rev. 7

6 www.liko.com l www.hill-rom.com 3.0 Spare Parts Assembly Information Assembly Instructions to Liko™ spare parts are attached with the products. The assembly instructions are also available in Agile and on the Partner Web. Document number to spare parts assembly instructions can be found in the spare parts list. Liko technical documentation can be found on the Partnerweb: https://partner.liko.com “My information” - “Documents” If you don’t have access, send a mail for registration to: [email protected] NOTE - Always make sure the spare part is mounted according to the assembly instruction. - Check all functions related to the changed spare part. - Repairs and maintenance may only be performed by personnel authorized by Hill-Rom and using original Liko™ spare parts. Actuator LA12 Ställdon LA12 Assembly Instruction Monteringsanvisning Prod. No. 31790001 3SE690217-02 2012-10-01 Tools required 17 mm 6 mm Contains: Qty: Actuator LA12 1 Locking ring D8 2 Screw K6S M10x35 1 Nut M10 1 Fits: 3124604 Traverse Switch NOTE - Make sure the spare part is mounted according to the assembly instruction. - Check all functions related to the changed spare part. - Repairs and maintenance may only be performed by personnel authorized by Hill-Rom/Liko and using original Liko spare parts. www.liko.com © Copyright Liko AB 4.497 1. Move the traverse switch to closed position, with � hand�control�or�fixed�switch. 2. Unplug the current from the actuator. 3. With the long nose plier remove the lower locking ring from the locking pin. 4. Remove the locking pin. 5. Unscrew the screw and nut. 6. Replace the old actuator. 7. Reassemble in reverse order. Connected to controlbox or multistation. 2 3 4 5 Document Number INFORMATION

Service Manual Traverse Switch • 3EN120401 Rev. 7

7 www.liko.com l www.hill-rom.com 4.0 Spare Parts List, Traverse Switch 3124604 Traverse Switch 497 Traverse Switch 20590010 449 Hand Control 2-button M220 pce 3SE650285 31790001 497 Actuator LA12 pce 3SE690217 31790002 498 Rail Warning label, 4 pce set  3SE690218 31290125 515 Damper Required on Carriage, installed in system with Traverse Switch, according to Installa- tion Handbook. pair 3SE640257 31290126 516 Damper QR Required on QR Carriage 3126008, installed in system with Traverse Switch, according to Installation Handbook. pair 3SE690224 STANNA INTE HAR / DO NOT STOP HERE STANNA INTE HAR / DO NOT STOP HERE 498 Spare Parts Positions PROD. NO. PRODUCT Liko™ Spare Parts Spare Parts List • Overhead Lifts 31 www.hill-rom.com l www.liko.com PROD. NO. POS. NO. NAME UNIT ASSEMBLY INSTR.

Service Manual Traverse Switch • 3EN120401 Rev. 7

8 www.liko.com l www.hill-rom.com 5.0 Periodic Inspection Information, Traverse Switch According to ISO 10535:2006 Annex B, Periodic Inspection of medical device Liko™ overhead rail systems should be performed at least once a year. Periodic Inspection Liko™ overhead rail system (3EN111001) is available in Agile and on the Partner Web. Periodic Inspection protocol Liko™ overhead rail system 3EN111001 Rev. 13 1(12) INSTALLATION Action required: Approved Not approved 1 Decal rail marking 2 General inspection 3* Rails 4 End stops 5 Ceiling/Wall attachments System information Customer reference Type of rail system: Agreement No: S/N: Name: Approved Max Load: Address: Year of installation: Post Code ADDITIONAL COMPONENTS N/A S/N: Action required: Approved Not approved 6* Rail Switches 7 Ultra Twist 8 Transfer Motor Traverse 9 Activity Rail 10 Pool Side Lifter ENVIRONMENTAL IMPACT 11 Corrosive environments LOAD TESTING Max Load applied: Approved Not approved 12 Maximum load rail system Kg: Lbs: REQUIRED MEASUREMENTS: N/A Dimension and unit Approved Not approved 3* Joint Gap mm: Inch: 6B* Rail Switch play mm: Inch: 6C* Turn Table clearance mm: Inch: Inspection sign off Complete inspection according to the instructions (page 2-11), fill in this page and sign below. Approval to use the overhead system Approved Not approved If the overhead system has one or more inspection points “Not approved”, the system must not be used. Action required: Actions according to the inspection items "NOT APPROVED" should be performed immediately. After performed actions sign below. If anything is unclear or if you have questions, please contact Hill-Rom or your local Hill-Rom representative. Contact information is to be found at www.hill-rom.com. Inspection performed by: Date: Next inspection: Inspection performed in accordance with ISO 10535:2006 Annex B- Periodic inspection Liko™ Overhead Rail System must be thoroughly inspected at least once per year. Inspection and service must be carried out by Hill-Rom authorized personnel. See "Installation condition checklist" on next page, to determine how to perform inspection points 2 and 5. Periodic Inspections are available for: Liko™ Overhead Lifts (3EN191001), FreeSpan and FreeStand (3EN301001), Accessories (3EN601001) and Mobile Lifts (3EN371001) North America only: For non Liko™ Rail system, use “Non Liko® Rail Installation Periodic Inspection” (193725) If printed: Make a colour print of this instruction. Liko technical documentation can be found on the Partnerweb: https://partner.liko.com - “My information” - “Documents” If you don’t have access, send a mail for registration to: [email protected] Periodic Inspection may only be performed by personnel authorized by Hill-Rom and using original Liko™ spare parts. Available Liko Periodic Inspections: • 3EN371001�Periodic�Inspection�Liko™�mobile�lifts • 3EN111001�Periodic�Inspection�Liko™�OH�rail�system • 3EN191001�Periodic�Inspection�Liko™�overhead�Lifts • 3EN301001�PI�Freespan™�-�Freestand™�freestanding�lift�systems • 3EN601001�Periodic�Inspection�Liko™�accessories Also available is Periodic Inspection Slings. This inspection should be performed by a person who is suitable, has good experience and sufficient knowledge about design, use and maintenance of the sling. • 7EN160834�General�Periodic�Inspection�Protocol�Liko�Slings�and�Sabina�SupportVests NOTE! Periodic Inspection shall be performed at least once per year. INFORMATION

6.0 Product Changes, Traverse Switch

Prod. No. 3124604 2014 Changes Revision Project To prevent noise from carriages in rail curves, new design of dampers are developed. The new dampers 31290125 (Damper) and 31290126 (Damper QR) are now delivered with the Traverse switch, and are replacing 31290096 (Damper) and 31290097 (Damper QR). Rev. 01 SUS000583 2012 Changes Revision Project Two�new�designs�of�Dampers,�that�prevents�the�Carriages�to�be�parked�in�the�wrong� area of the Travers switch are now delivered with the Traverse switch. The new Dampers 31290096 (Damper) and 31290097 (Damper QR) are replacing 31290072 (End Stop) Rev. 01 1778 2011 Changes S/N Project New�attachment�for�the�traverse�switch�actuator.�The�configuration�allows�change�of� position�of�the�actuator,�from�the�fixed�rail�to�the�secondary�rail�in�the�overhead�system.� The�slimline�pendant�has�expired�so�the�Traverse�switch�stabilization�bar�has�been�updated� to�fit�the�pendants�that�are�used. 6052700 1102 2006 Changes New Prod. No 3124604 (old Prod. No 3124603), due to changed traverse plate. Prod.�No�3124604�has�Traverse�plate�prim�according�to�drawing�R3024023-3 Prod.�No�3124603�has�Traverse�plate�prim�according�to�drawing�R3024023-2 New�design�on�traverse�plate�and�actuator.�The�new�actuator�opens�and�closes�in�two�seconds�(four�times�faster).� The switch has new traverse plate that prevent stop of the carriages between the rails. NB! Always use end stop adapters on the carriages! Special�Installation�instruction�for�Traverse�Switch. Service Manual Traverse Switch • 3EN120401 Rev. 7 9 www.liko.com l www.hill-rom.com