Global leader in wind measurement technology
110 Riggs Road · Hinesburg · VT 05461 USA · TEL (802) 482-2255 · FAX (802) 482-2272 · EMAIL [email protected]
SymphoniePLUS_Sensor_Connection_instructions.doc
Rev 4
31 March 2010
NRG Sensor Connections to SymphoniePLUS
Introduction
These instructions will assist you in connecting standard NRG sensors to a SymphoniePLUS logger and also
provide the default slope and offset for each sensor type. These default values are preloaded in the
SymphoniePLUS logger (except for iPack voltmeter and RMY Vertical Prop Anemometer) and the Symphonie
Data Retriever (SDR) software. The values are included here as a quick reference only - please see the
SymphoniePLUS manual for logger channel configuration.
Connections
Global leader in wind measurement technology
110 Riggs Road · Hinesburg · VT 05461 USA · TEL (802) 482-2255 · FAX (802) 482-2272 · EMAIL [email protected]
SymphoniePLUS_Sensor_Connection_instructions.doc
Rev 4
31 March 2010
Default Slope and Offsets for Symphonie
Both the SymphoniePLUS logger and SDR software come loaded with default slope and offset values for our
standard sensors. Please note that these settings are specific to Symphonie and SymphoniePLUS and may not
be the same values used for other data loggers. Some sensors are provided with sensor specific values that
may be used in place of these defaults.
Sensor Default Slope and Offsets for use with SymphoniePLUS
Sensor
Slope
Offset
Scaled Units
NRG #40 Anemometer
0.765
0.35
m/s
NRG #200P Wind Direction Vane
0.351
0
degrees
NRG #110S Temperature Sensor with Radiation Shield
0.136
-86.38
C
NRG #BP20 Barometric Pressure Sensor
0.4255
650
mB
Relative Humidity Sensor
0.097
0
%RH
Li-Cor #LI-200SA Pyranometer
1.32
0
W/sqm
Rain Gauge-Tipping Bucket
0.254
0
mm
***iPack Voltmeter SCM***
0.021
0
Volts
RMY Vertical Prop Anemometer
0.0293
-15.00
m/s