METHVEN Tahi 01-6150 Installation Manual

Specifications

Brand: METHVEN
Category: Bathroom Fixtures
Model: Tahi 01-6150 (Installation Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the METHVEN Tahi 01-6150 Installation Manual online using the built-in PDF viewer.

Text of the manual

Methven Australia Pty Ltd

ABN 15 104 813 390 Melbourne, Australia www.methven.com www.methven.com Customer Care Hotline: 1300 METHVEN (638 483) Email: [email protected] - + - + Hot Distance from mounting stud to front of lining: Max 67 mm (optimum) Min 56mm Note: It is the responsibility of the installer to ensure a water proof seal is achieved between the faceplate and the finished surface of the wall. If in any doubt about the quality of the seal, the faceplate should be removed and then reinstalled using silicone to ensure a seal is achieved. MA016150 Tahi Shower Mixer 01-6150 JULY 2011 WMKA00076 Remove half-dome (if attached) Flow limiting adjustment Mix temperature limiting adjustment 1.5mm Allen Key IMPORTANT Please read all of the instructions before installation Use of this product is recommended for domestic and commercial applications. Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website for full warranty terms and conditions - www.methven.com All pipework must be thoroughly flushed prior to the installation of the mixer. Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles damaging the ceramic cartridge. Do not remove the ceramic cartridge from the mixer when installing. Damage caused by hydrostatic testing is not covered by Methven’s warranty. Methven recommends a licensed plumber carry out all installations in compliance with the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations. Installation Guide Illustration may not reflect actual product shape Do not discard screws Refer to back page for correct nozzle selection Hole cutout 102mm Apply silicone sealant Cold 2.5mm Hex key 1 2 3a 3b 4 5-7 Ceramic Cartridge Adjustment Do not remove the ceramic cartridge from the body while carrying out the following adjustments. Note: the cartridge is factory set for maximum temperature. Installation 1. Remove body assembly cover. Do not discard cover or screws (3). 2. Screw the body assembly (1) into the mounting stud. 3. Plumb body assembly (1) into system and replace body assembly cover. The minimum distance from mounting stud to front wall lining is 56mm with a maximum distance of 67mm (optimum). Note: Body assembly cover will need to be removed before wall surface finish (tiling) is applied. A hole diameter of 102mm will be required for correct mixer installation. 4. Place faceplate (2) over mixer body and fit flush with wall surface. It is recommended that a bead of clear silicone sealant is applied on the back of the faceplate before fixing to finished wall surface. 5. Screw the faceplate (2) into the fixing ring using the screws (3) taken from the body assembly cover. 6. Place the O-ring (4) and half dome (5) over the body assembly. 7. Fit handle (6) and fasten grub screw with 2.5mm hex key (8)

Please check every component in accordance

with the table below No. Item description Qty supplied 1 Body assembly 1 2 Faceplate 1 3 Screws 2 4 O-ring 1 5 Half Dome 1 6 Lever Handle with grub screw 1 7 1.5mm hex key (not shown) 1 8 2.5mm hex key (not shown) 1 THE METHVEN GUARANTEE The warranty statement shall apply to all tapware & showers supplied by Methven For more information visit www.methven.com THIS WARRANTY ISSUED BY: Methven Australia Pty Ltd, Melbourne Australia Technical Specification Inlet Connections: All 1/2" BSP Operating Pressure: 150kPa - 500kPa For optimum performance hot and cold water pressures should be equal. AS/NZS 3500 stipulates a 500kPa maximum operating pressure at any outlet within a building. Where normal pressure exceeds 500kPa, a pressure limiting valve must be installed. Operating Temperature: Recommended hot water supply 50°C, maximum 70°C. AS/NZS 3500 requires all hot water supplies to any sanitary fitting to be tempered to 50°C. Ceramic cartridges: Warranty claims will be void where the ceramic cartridge has malfunctioned due to the presence of the following within the water supply: Copper tube pieces Plastic pieces Sand, dirt or stones Thread tape Other objects not normally present in the potable water supplies Piping RequirementS for Mixers Avoid restrictive piping, fittings or sharp angled bends when plumbing the mixer. Do not hydrostatic test* the installation with this mixer installed. Damage to the ceramic cartridge may occur, voiding warranty. Hydrostatic testing refers to placing the system under pressure, above the recommended operating pressure, to determine water tightness and to uncover leaks or weak joints within the system. Care and cleaning Never use abrasives to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth. Damage caused by using unsuitable cleaning agents is not covered by warranty. www.methven.com Customer Care Hotline: 1300 METHVEN (638 483) Email: [email protected] 5 Faceplate Screws O-ring Fixing Ring Body assembly Lever handle Grub screw Half-Dome Seal 6 4 3 2 1 3

Other Bathroom Fixtures Manuals