METHVEN Tahi 01-6150 Installation Manual
Read Online
Read the METHVEN Tahi 01-6150 Installation Manual online using the built-in PDF viewer.
Text of the manual
Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
www.methven.com
Customer Care Hotline: 1300 METHVEN (638 483)
Email: [email protected]
-
+
-
+
Hot
Distance from
mounting stud to
front of lining:
Max 67 mm
(optimum) Min 56mm
Note: It is the responsibility of the installer to ensure a water proof seal
is achieved between the faceplate and the finished surface of the wall.
If in any doubt about the quality of the seal, the faceplate should be
removed and then reinstalled using silicone to ensure a seal is achieved.
MA016150
Tahi Shower Mixer
01-6150
JULY 2011
WMKA00076
Remove half-dome
(if attached)
Flow limiting adjustment
Mix temperature limiting
adjustment
1.5mm Allen Key
IMPORTANT
Please read all of the instructions before installation
Use of this product is recommended for domestic and commercial applications.
Domestic and commercial warranty terms and conditions vary. Please refer to the Methven website
for full warranty terms and conditions - www.methven.com
All pipework must be thoroughly flushed prior to the installation of the mixer.
Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles
damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
Damage caused by hydrostatic testing is not covered by Methven’s warranty.
Methven recommends a licensed plumber carry out all installations in compliance with
the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.
Installation Guide
Illustration may not reflect actual product shape
Do not discard screws
Refer to back page
for correct nozzle selection
Hole cutout
102mm
Apply silicone
sealant
Cold
2.5mm Hex key
1
2
3a
3b
4
5-7
Ceramic Cartridge
Adjustment
Do not remove the ceramic cartridge from the body while
carrying out the following adjustments.
Note: the cartridge is factory set for maximum
temperature.
Installation
1. Remove body assembly cover. Do not discard cover or
screws (3).
2. Screw the body assembly (1) into the mounting stud.
3. Plumb body assembly (1) into system and replace body
assembly cover. The minimum distance from mounting stud
to front wall lining is 56mm with a maximum distance of
67mm (optimum).
Note: Body assembly cover will need to be removed
before wall surface finish (tiling) is applied. A hole
diameter of 102mm will be required for correct mixer
installation.
4. Place faceplate (2) over mixer body and fit flush with wall
surface. It is recommended that a bead of clear silicone
sealant is applied on the back of the faceplate before fixing
to finished wall surface.
5. Screw the faceplate (2) into the fixing ring using the screws
(3) taken from the body assembly cover.
6. Place the O-ring (4) and half dome (5) over the body
assembly.
7. Fit handle (6) and fasten grub screw with 2.5mm hex key (8)
Please check every component in accordance
with the table below
No. Item description
Qty supplied
1
Body assembly
1
2
Faceplate
1
3
Screws
2
4
O-ring
1
5
Half Dome
1
6
Lever Handle with grub screw
1
7
1.5mm hex key (not shown)
1
8
2.5mm hex key (not shown)
1
THE METHVEN GUARANTEE
The warranty statement shall apply to all tapware & showers supplied by Methven
For more information visit www.methven.com
THIS WARRANTY ISSUED BY: Methven Australia Pty Ltd, Melbourne Australia
Technical Specification
Inlet Connections:
All 1/2" BSP
Operating Pressure:
150kPa - 500kPa
For optimum performance hot and cold water pressures should be equal.
AS/NZS 3500 stipulates a 500kPa maximum operating pressure at any outlet
within a building. Where normal pressure exceeds 500kPa, a pressure limiting
valve must be installed.
Operating Temperature:
Recommended hot water supply 50°C, maximum 70°C. AS/NZS 3500 requires all
hot water supplies to any sanitary fitting to be tempered to 50°C.
Ceramic cartridges:
Warranty claims will be void where the ceramic cartridge has malfunctioned due to
the presence of the following within the water supply:
Copper tube pieces
Plastic pieces
Sand, dirt or stones
Thread tape
Other objects not normally present in the potable water supplies
Piping RequirementS for Mixers
Avoid restrictive piping, fittings or sharp angled bends when plumbing the mixer.
Do not hydrostatic test* the installation with this mixer installed. Damage to the ceramic cartridge may
occur, voiding warranty.
Hydrostatic testing refers to placing the system under pressure, above the recommended operating pressure, to determine water
tightness and to uncover leaks or weak joints within the system.
Care and cleaning
Never use abrasives to clean this product. Clean regularly with contamination free warm soapy water
and a damp soft cloth. Damage caused by using unsuitable cleaning agents is not covered by warranty.
www.methven.com
Customer Care Hotline: 1300 METHVEN (638 483)
Email: [email protected]
5
Faceplate
Screws
O-ring
Fixing Ring
Body assembly
Lever handle
Grub screw
Half-Dome
Seal
6
4
3
2
1
3