Crestron GLS-ODT-C-2000 Operations & Installation Manual

Specifications

Brand: Crestron
Category: Stud Sensor
Model: GLS-ODT-C-2000 (Operations & Installation Manual)
File Type: PDF
File Size: 0.73 Mb
Pages: 2

Read Online

Read the Crestron GLS-ODT-C-2000 Operations & Installation Manual online using the built-in PDF viewer.

Text of the manual

Crestron Electronics, Inc.

Operations & Installation Guide - DOC. 6769C 15 Volvo Drive Rockleigh, NJ 07647 (2023016) Tel: 888.CRESTRON 09.11 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice. These instructions include three typical installation options (A, B, and C). Choose one that best suits your needs. Other methods may be possible but they are not described here. Parts Supplied Sensor (1) Threaded Rod (1) and Hex nut (1) #8-32 x 1/2 inch screw (2) Half Mask (1) #8-32 x 1-1/2 inch screw (2) 360º Perforated Mask (1) #8x32 Washer and Nut (2) Plastic Washer (1) Tools/Equipment Required (not supplied) Phillips Screwdriver Electrical Tape Pliers Pencil Diagonal Cutters Model/Feature Basics The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the GLS-SIM (or other compatible interface) to automatically control lighting. The exact behavior of the sensor can be configured via software, but the sensor is typically used to turn lights on when a room or area is occupied, and to shut them off when the room or area is vacated. The sensor continually analyzes and adjusts to changing conditions. The sensor uses the latest microprocessor-based technology which permits it to continually adjust and optimize its performance. The combination of ultrasonic (doppler shift) motion detection, which gives maximum sensitivity, and infrared motion detection, which gives higher false triggering immunity, yields a sensor with excellent performance. Crestron GLS-ODT-C-500/1000/2000 Dual-Technology Ceiling Mounted Occupancy Sensor Operations & Installation Guide Coverage 500 sq. ft (46.45 sq. m) 1000 sq. ft. (92.9 sq. m) 2000 sq. ft. (185.8 sq. m) Suggested Location Mount in corner/ over doorway Mount in center of room/area Mount in center of room/area Model No. GLS-ODT-C-500 Description 1-Way Dual-Technology 2-Way Dual-Technology 2-Way Dual-Technology Operating Frequency 40KHz 40KHz 32KHz Current Consumption 30mA 40mA 32mA GLS-ODT-C-1000 GLS-ODT-C-2000 24 1 2 G optional Sensor #2 ( ) Red Black Black Red Red Blue* Sensor #1 Black Red Blue2 Connecting Sensors to the GLS-SIM Connecting Sensors to the DIN-IO8 or Equivalent1 *To incorporate the internal photocell, connect gray wire to GLS -SIM and cap off blue wire from sensor. Gray 2 (cap off) Gray* (cap off) –SENSOR– ––– NET––– 24 Y Z G Use CRESNET-P or CRESNET-NP wire only GLS-SIM Sensor #1 optional Sensor #3 ( ) To Control System G 1 2 3 4 ––– NET G 1 2 3 4 24 Y Z G 24 Y Z G ––– To Control System ––– ––– I/O DIN-IO8 NOTE: The same Crestron power supply MUST be used to power both the sensors and the interface device (e.g., DIN-IO8). Otherwise, there is a risk of damage to the interface device. 2To incorporate the internal photocell, connect the gray wire to the DIN-IO8 (or other interface device) and cap off the blue wire from the sensor. Black Blue* Blue* 1The following Crestron devices may be used to integrate the sensors into a Cresnet system by following the schematic shown here: DIN-IO8 DIN-AP2 PAC2 PRO2 AV2 CP2E MP2E CNXIO16 Any Crestron product with Versiports Use CRESNET-P or CRESNET-NP wire only CRESNET-P or CRESNET-NP wire recommended, 250 feet (76 m) max. If using input 1 If using input 2 1 2 3 4 ON ON ON ON DIP Switch Settings Blue or White Red Black All wires from sensor to GLS-SIM must be 24 AWG minimum. (If GLS-SIM is not located adjacent to the sensor, use CRESNET-P or CRESNET-NP wire.) To ensure correct processing of the sensor’s output from all interface devices (other than the GLS-SIM), the SIMPL program for the control processor must disable the pull-up resistor built in to the Versiport input connector. This is accomplished by setting the “pu-disable” digital input signal to a “1.” The Versiport output can also be inverted using logic such as a NOT symbol to generate a logic “high” when the room is occupied. • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, consult a qualified electrician. • Sensors must be mounted on a vibration free surface. • All sensors must be mounted at least 6 feet (1.8 m) away from air vents. • Do not mount sensors closer than 10 feet (3 m) from each other. • Do not touch the inner surface of the lens. Clean outer surface with a damp cloth only. WARNING: To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before wiring! CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators). NOTES: Observe the following points. Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. For assistance in your region, please refer to the Crestron Web site (www.crestron.com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron Web site (www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Future Updates As Crestron improves functions, adds new features and extends the capabilities of the GLS-ODT-C units, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron Web site periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column. When wiring the Cresnet® network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. Network Wiring SETUP Preparing and Connecting Wires Strip the ends of the wires approximately 1/2 inch (13 mm). Use care to avoid nicking the conductors. Twist together the ends of the wires that share a connection and tin the twisted connection. Apply solder only to the ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle. DESCRIPTION INSTALLATION INSTRUCTIONS WIRING DIAGRAMS FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. 1 2 3 4 ON 1 2 3 4 ON By masking two sections, you can block hallway traffic Masking is not required in a corner mounting application. The sensor can not see hallway traffic. Mask 1. Select the location for mounting the sensor and proper masking for your application. (Refer to Mounting/Masking Location Diagram). 2. Use the supplied threaded rod or other means to make a hole (1/2 to 1 inch [13 to 26 mm]) in the ceiling tile just large enough to pass the shaft of the threaded rod through. 3. Insert the sensor wires through the flared end of the threaded rod. Position the threaded rod to the base of the sensor. 4. Insert the flared end of the threaded rod into the opening in the bottom of the sensor and twist to lock into place. 5. Push the wires into the hole in the ceiling tile and insert the threaded rod until the sensor is flush with the tile. 6. Insert wires through the hole in the included washer, then place the washer over the rod and secure in position using the included hex nut. 7. Connect low voltage wires from the GLS-SIM or other Crestron® device as shown in the wiring diagram. Twist strands of each lead tightly and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape. 8. Rotate the sensor to the desired orientation. Note that the sensor base and backcover are keyed. To lock the device in place, ensure that the arrows are not aligned. 9. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE. Mounting to Drop Ceiling Using Threaded Rod Low-Voltage Wires NOTE: Wires routed through the Threaded Rod Drop Ceiling 1" thick maximum Nut Washer Threaded Rod 5. Connect low voltage wires from the GLS-SIM or other Crestron device as shown in the wiring diagram. Twist strands of each lead tightly and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape. 6. Push wire connections through the center hole of the back cover and into the ceiling. 7. Secure the sensor body to the back cover by aligning the arrows. Lock it by turning the sensor such that the arrows do not line up. 8. Rotate the sensor to the desired orientation. 9. Restore power at the circuit breaker or fuse. INSTALLATION IS COMPLETE. Low-Voltage Wires Wallboard Ceiling Sensor Back Cover Sensor Base Keylock Arrow Mounting Screws (2 places) Sensor Front Cover Back Cover open center to route Low-Voltage Wires Mounting Screw Back Cover internal surface shown Back Cover shown mounted on ceiling with screws Nut (2 places) Washer (2 places) Mounting to Drop Ceiling Using Screws Option B. Drop Ceiling Installation Using Screws NOTE: You may use the mounting screws, nuts and washers included, or screws in combination with commercially available wall anchors. 1. Select the location for mounting of the sensor and proper masking for your application (Refer to Mounting/Masking Location Diagram). 2. Make a hole in the ceiling tile large enough to pass the wire connections and wire nuts through (approximately 1 inch [26 mm] diameter). 3. Remove the back cover of the sensor. Hold the back cover and body of the sensor and rotate until the two arrows line up, and pull them apart. 4. Install back cover of the ceiling sensor to the wallboard or drop ceiling using the included screws, nuts and washers, or screws in combination with commercially available wall anchors. Option B. Drop Ceiling Installation Using Screws (Cont’d) Option C. Back Box or Surface Mount Raceway Installation Drop Ceiling Mounting to Octagon Back Box Installed Flush to Drop Ceiling GLS-SIM Cresnet® GLS-ODT-C-500/1000/2000 Up to Three in Parallel The supplied masks mount in the sensor front cover. The half mask is supplied pre-mounted to demonstrate the mounting method. The perforated mask has twelve 30º removable segments that allow you to mask particular areas to prevent undesire- able triggers from affecteng the sensor operation. The following illustrations provide typical application examples. 1. Select the location for mounting of the sensor and proper masking for your application (Refer to Mounting/Masking Location Diagram). 2. Refer to the suggested mounting option illustrations below. Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation DIN-IO8 GLS-ODT-C-500/1000/2000 Cresnet® GLS-SIM (Optional) Crestron 2-Series Control Processor or CLS-C6 Crestron 2-Series Control Processor Option A. Drop Ceiling Installation Using Supplied Threaded Rod MOUNTING/MASKING LOCATION DIAGRAM TYPICAL APPLICATION DIAGRAMS SPECIAL PROGRAMMING #8-32 Screws (2 places) Octagon Back Box 4" x 1 1/2" deep Low-Voltage Wires GLS-SIM (Optional) Low-Voltage Wires Wallboard Ceiling GLS-SIM (Optional) Wire Mold Back Cover Back Cover Screws (4 places) Wire Mold Round Fixture (for raceway mount) Mounting Screws (4 places) Wire Mold Raceway (use applicable fittings)

Minor Motion, Ultrasonic

Major Motion, Ultrasonic Major Motion, IR Field-of-View Ranges - GLS-ODT-C-500 0 20 11.5 11.5 8.5 8.5 20 SIDE VIEW TOP VIEW 23 7 1 3 2 17 8 0 11 11 15 15 20 20 9 9 3 3 0 5.6 5.6 Minor Motion, Ultrasonic Major Motion, Ultrasonic Major Motion, IR 0 20 8 16 16 11.5 11.5 20 SIDE VIEW TOP VIEW 0 3 3 5.5 5.59 9 1 1 1 1 5 1 5 1 0 2 0 2 32 32 5.2 2 5.2 2 Minor Motion, Ultrasonic Major Motion, Ultrasonic Major Motion, IR Adjustment Knob Settings KNOB COLOR FUNCTION Sets the ultrasonic range Sets the infrared range Delayed- Off Time Ambient Light Override (Gray wire only) KNOB SETTING Range setting Full CCW = min. (OFF) Full CW = max. Range setting Full CCW = min. (OFF) Full CW = max. Full CCW = min. (30 sec.) Full CW = max. (30 min.) DEFAULT SETTING 75% 50% 100% Full CCW – Lights stay OFF Full CW – Lights always turn ON (NO ambient light override) Range– 100-3000 LUX 50% (10 min) Blue Black Red Green SYMBOL A B ON ON 1 1 A B ON ON 1 1 Minimum and Default Settings Minimum Setting Factory Default Setting MIN MAX Adjust Knob Rotation Direction DIP Switches 30 sec 5 min 30 min 20 min 10 min Delayed Off Time Selection (Black Knob) B3 • Dual-Tech Mode. This is the default mode of operation for the sensor. Passive infrared technology (PIR) turns lights on in this mode; however, motion detection by either technology (PIR or ultrasonic) will keep the lights on. If neither technology detects motion, the lights turn off after the delayed-off time. • Single-Tech Mode. Only one technology is active in this mode. The technology is selected by the dip switches. Motion detection by the selected technology - PIR or ultrasonic - will turn on the lights as well as keep them on. When motion is not detected, the lights will turn off after the delayed-off time. • Delayed-Off Time. The sensor is designed to turn the lights off if no motion is detected after a specified time. This length of time is called the delayed-off time and is set using the timer (black) knob on the sensor. The adapting patterns will modify the delayed-off time to fit the parameters of each installation based on environmen- tal conditions and occupancy patterns. • Walk-through Mode. The walk-through feature is useful when a room is momen- tarily occupied. With this feature, the sensor will turn the lights off shortly after the person leaves the room. The walk-through feature works as follows: When a person enters the room, the lights will turn on. If the person leaves the room before the walk-through time-out of 2.5 minutes, the sensor will turn the lights off. If the person stays in the room for longer than 2.5 minutes, the sensor will proceed to the Occupied mode. • LED Operation. There are two LED indicators that will flash when motion is detected. The LED flash can be disabled using the LED disable switch setting. Green flashes indicate motion detection by ultrasonic technology. Red flashes indicate motion detection by infrared technology. The sensor continually analyzes the parameters of the motion detection signal and adjusts its internal operation to maximize detection of motion while minimizing the effects of noise (electrical noise, air currents, temperature changes, etc.). Operation When the lights turn on, the sensor initially begins the Walk-through mode. Once the room is occupied for longer than 2.5 minutes, the sensor ends the Walk-through mode and begins the Occupied mode. When the sensor is first installed, the delayed-off time for the Occupied mode is based on the time adjustment settings. While the sensor is in use, the delayed-off time will change, based on how the sensor adapts to the room conditions. Whenever the sensor subsequently turns on, the value of the delayed-off time will be the adapted value (refer to Occupancy Pattern Learning For Delayed Off Time). The adapted settings can be reset using the DIP switch. Occupancy Pattern Learning For Delayed Off Time The sensor will automatically change the delayed off time in response to the occupancy and environmental conditions of the space where it is installed. The sensor analyzes the motion signal properties and will minimize the delayed off time duration when there is frequent motion detection, and lengthen the delayed off time duration when there is weak and infrequent motion detection. In the case of a false-off condition (lights turn off when the room is occupied), the delayed off time duration will immediately be lengthened to prevent further false turn offs. Occupancy Pattern Learning for Ultrasonic Technology The sensor learns the occupancy patterns of a space during the course of a day, for a seven day period. At any given time, the sensor will look at the collected data and adjust its ultrasonic sensitivity. The sensor will adjust the sensitivity to make it less likely to turn on during a period of non-occupancy and more likely to turn on during a period of occupancy. This adapting feature is not applicable when the sensor is using PIR functions only. The two tables (below and in the next column) and the “Minimum and Default Settings” illustration define the settings of the adjustment knobs and the DIP switches. * This setting is only used if the Single Technology Option (Switch A1) is selected. SWITCH FUNCTIONS Bank A OFF ON Single/Dual-Tech Mode Dual-Tech Single Tech PIR/Ultrasonic Mode PIR Ultrasonic Manual Mode Auto Adapting Enabled Auto Adapting Disabled Walk-Through Disable Walk-Through Enabled Walk-Through Disabled Bank B Override to ON Auto Mode Lights Forced ON Override to OFF Auto Mode Lights Forced OFF Test Mode OFF ON OFF = Enter/Exit Test Mode LEDs Disable LEDs Enabled LEDs Disabled DIP Switch Settings SWITCH SETTINGS SWITCH A1 A2* A3 A4 B1 B2 B3 B4 Field-of-View Ranges - GLS-ODT-C-2000 Field-of-View Ranges - GLS-ODT-C-1000 To set the Photocell level (used with the gray wire connection): 1. Remove the cover from the sensor. 2. Make note of the position of the red and green knobs. Rotate the red and green knobs fully CCW and enter the sensor’s Test mode as described above. 3. Rotate the blue knob fully CCW. 4. Wait for the lights to turn OFF. 5. Rotate the red knob fully CW. 6. Slowly rotate the blue knob clockwise until the lights turn ON. This is the correct setting. 7. Return the red and green knobs to their original positions 8. Replace the cover. Photocell level setting is complete. NOTE: This setting must be performed when the natural light is low enough to require artificial light. 1. ENSURE POWER IS ON. 2. Remove front cover. 3. Locate Dip Switch 3 in Bank B (B3). B3 will be in the OFF position from the factory. 4. To start Test mode, move switch to ON and back to OFF. The Test mode has now been initiated with a six second time-out. (Refer to the DIP Switch Settings table.) NOTE: If B3 is already in the ON position, then Test mode can be entered by just moving it to the OFF position. NOTE: The timer will remain in the six second Test mode for 15 minutes, then automatically exit Test mode and reset to the delayed-off time setting as defined by the black timer knob. NOTE: To manually take the timer out of the six second Test mode, simply toggle the switch B3 from OFF to ON and back to OFF. Set the delayed-off time to six seconds for performing a walk test. While the sensor is in Test mode, the LEDs will flash amber once a second. In order to use the ambient light override functionality of the sensor, the sensor must be wired to the GLS-SIM (or other compatible interface) using the gray wire instead of the blue wire. This feature allows the user to conserve energy by keeping the controlled lights off when not necessary. The sensor does this by measuring the amount of ambient light in the installed area and keeping the controlled lights off if there is enough ambient light available. To use this feature, the photocell adjustment (blue) knob must be adjusted from the default position. Once this adjustment is made, the controlled lights will only turn on if the ambient light present is less than the setting. The descriptions below refer to a system which has been configured to turn the lights on when a room or area is occupied, and turn them off when the room or area is vacated. Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address. 2. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. 3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser. CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touch screen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed. This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party. CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty. Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. NOTE: Operation is ultimately determined by the control system program, and that must be considered when troubleshooting. Lights do not turn ON. TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION Circuit breaker or fuse has tripped. Reset circuit breaker or replace fuse. Connections between sensor and GLS-SIM (or other interface device) have been miswired. Verify that all connections have been made per the wiring diagrams in this document. Lights stay ON. Constant motion. To test, reduce red and green knob by 15%; remove motion source. If no change, move sensor. Infrared sensor can “see” into hallway. To test, put sensor in timer Test mode and walk hallway. If lights continue to come ON, move sensor. Lights remain ON too long. Timer setting too high. To test, check switch settings. Typical setting is 10 minutes. Incorrect programming in control system. Check control system logic and pull-up resistor setting or contact Crestron for assistance. GLS-SIM (or other interface device) set to incorrect Net ID. Check that the Net ID matches the one expected by the control system (or CLS-C6). GLS-SIM DIP switch settings not correct. Refer to wiring diagrams on first page of this document for appropriate settings. Incorrect programming in control system. Check control system logic or contact Crestron for assistance. ADJUSTMENT KNOB AND SWITCH SETTINGS TEST MODE PHOTOCELL (AMBIENT LIGHT OVERRIDE) ADJUSTMENT TROUBLESHOOTING Crestron, the Crestron Logo and Cresnet are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and other countries. EMerge Alliance and the EMerge Alliance logo are either trademarks or registered trademarks of EMerge Alliance Corporation in the United States and/or other countries. Other trademarks, registered trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others ©2011 Crestron Electronics, Inc. OPERATION ADAPTIVE FUNCTIONS

Other Stud Sensor Manuals