VM-218DTxr Quick Start

P/N: 2 9 0 0 - 3 0 0 6 2 2 QS Rev: 4 Scan for full manual VM-218DTxr Quick Start Guide This guide helps you install and use your VM-218DTxr for the first time. Go to www.kramerav.com/downloads/VM-218DTxr to download the latest user manual and check if firmware upgrades are available. Step 1: Check what’s in the box VM-218DTxr HDMI/HDBT Switcher/DA 1 Quick start guide 1 Set of rack ears 1 Power cord 4 Rubber feet Step 2: Get to know your VM-218DTxr # Feature Function 1 IR LED Lights orange when the unit accepts IR remote commands. 2 IR Sensor Use to control a peripheral device connected to OUT 2 HDBT with that device’s remote controller. 3 POWER LED Lights when the unit is powered. 4 VOLUME () Press to decrease the volume of the analog audio output. 5 VOLUME () Press to increase the volume of the analog audio output. 6 INPUT Selector Button Press to select input 1 HDMI™ or input 2 HDBT. 7 INPUT LEDs Lights green to indicate the selected input: 1 HDMI or 2 HDBT. 8 EDID READ Button Press to read the selected EDID and write it to both inputs. 9 EDID SELECT Button Press to cycle through the sources from which to read the EDID: Default, External, or Output. When Output is selected, cycles through outputs 1 to 9. The relevant EDID TYPE and OUTPUT LEDs light green. 10 EDID TYPE LEDs Lights green to indicate the selected EDID type: DEFAULT, EXT. (external) or OUTPUT. 11 OUTPUT LEDs (1 to 9) In normal operation mode: lights green when an acceptor is connected to the output. In EDID mode: when EDID TYPE OUTPUT LED lights green, press the EDID SELECT button briefly to cycle through output 1 to 9 to select the output from which to read EDID. The relevant LED lights during EDID setup and remains lit after completing the EDID setup. The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.

IN 2 IR on a 3.5 Mini Jack

Connect to an IR emitter/sensor cable for IR link extension via IN 2 HDBT. 13 IN 2 RS-232 (G, Rx, Tx) Terminal Block Connector Connect to a serial controller for RS-232 link extension via IN 2 HDBT. 14 IN 1 HDMI™ Connector Connect to an HDMI source. 15 IN 2 HDBT on RJ-45 Connectors Connect to an HDBT transmitter (for example, TP-780Txr). 16 IR on 3.5 Mini Jacks (for OUT 2 to 9) Connect to remote IR emitter/sensor cables to IR control the devices that are connected to the HDBT acceptors. 17 RS-232 OUT (G, Rx, Tx) Terminal Block Connectors (2 to 9) Connect to serially control the devices connected to the HDBT acceptors. 18 OUT 1 HDMI Connector Connect to the HDMI input of an additional DA or connect to a local monitor. 19 OUT HDBT RJ-45 Connectors (2 to 9) Connect to HDBT receivers (for example, TP-780Rxr). 20 AUDIO OUT 3.5mm Mini Jack Connect to an analog audio acceptor. 21 RS-232 CONTROL 3-pin Terminal Block Connect to the serial controller to control the VM-218DTxr. 22 REMOTE 3-pin Terminal Block For future use. 23 SETUP DIP-switches Use to set the device behavior. 24 ETHERNET RJ-45 Connector Connect to LAN for Ethernet extension via IN and OUT HDBT ports and remote IP control of the VM-218DTxr. 25 RESET Button Press and hold while powering on the device to reset to factory default parameters. 26 PROG Mini USB Connector Connect to a PC to perform firmware upgrades. 27 Mains Power Connector, Fuse, and Switch Connect to the mains supply. Step 3: Install VM-218DTxr To rack mount the machine, attach both rack ears (by removing the screws from each side of the machine and replacing those screws through the rack ears) or place the machine on a table. • Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device. • Avoid uneven mechanical loading. • Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits. • Reliable earthing of rack-mounted equipment should be maintained. Step 4: Connect the inputs and outputs Always switch OFF the power on each device before connecting it to your VM-218DTxr. For best results, we recommend that you always use Kramer high-performance cables to connect AV equipment to the VM-218DTxr.

Changes to the DIP-switches only take effect on power-up. After changing a switch, reboot the device. All DIP-switches are set to

Off (up) by default. # Feature Dip-switch Settings 1 Reserved 2 Range mode On (down) – HDBaseT Ultra-long range (provides increased range at a reduced bandwidth). Off (up) – Normal range (default). Note that range mode affects the HDBT input only 3 Audio de-embedding On (down) – Disable audio de-embedding. Note that the audio output port is muted. Off (up) – Enable audio de-embedding to the analog audio output port (default). 4 Force RGB On (down) – Force RGB mode. Off (up) – Normal mode (default) For optimum range and performance use the recommended Kramer cables available at www.kramerav.com/product/VM-218DTxr. Step 5: Connect the power Connect the power cord to VM-218DTxr and plug it into the mains electricity. Safety Instructions (See www.kramerav.com for updated safety information) Caution: • For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. • There are no operator serviceable parts inside the unit. Warning: • Use only the power cord that is supplied with the unit. • Disconnect the power and unplug the unit from the wall before installing. Step 6: Operate the VM-218DTxr Web pages: RS-232 and Ethernet: RS-232/Ethernet Baud Rate: 115,200 Parity: None Data Bits: 8 Command Format: ASCII Protocol 3000 Stop Bits: 1 Example (Route input 1 to output 1): #ROUTE 1,1,1 Ethernet Parameters IP Address: 192.168.1.39 Subnet Mask: 255.255.0.0 Default UDP Port #: 50000 Default Gateway: 192.168.0.1 Full Factory Reset Front Panel Buttons: Front panel buttons: power off the device, press and hold the RESET button for 3 seconds while powering the device, and then release. Protocol 3000: “#factory” command. Web Pages: In the Device Settings page, click Reset.

On a female HDMI connector

1 HDBT On an RJ-45 connector Outputs 1 HDMI On a female HDMI connector 8 HDBT On RJ-45 connector 1 Unbalanced Stereo Audio On a 3.5mm mini jack Ports 1 IR IN On a 3.5mm mini jack for IR link extension via IN 2HDBT 8 IR OUT On 3.5mm mini jacks for IR link extension via OUT HDBT (2 to 9) 1 RS-232 IN On a 3-pin terminal block for serial link extension via IN 2HDBT 8 RS-232 OUT On 3-pin terminal blocks for serial link extension via OUT HDBT (2 to 9) 1 Mini USB On a female USB connector for firmware upgrade 1 RS-232 On a 3-pin terminal block for device control 1 10/100BaseT Ethernet On an RJ-45 female connector for device control via LAN and Ethernet link extension via IN HDBT and OUT HDBT (2 to 9) Extension Reach 4K @60Hz (4:2:0) Up to 100m (330ft) Full HD (1080p @60Hz 36bpp) Up to 130m (430ft) HDBaseT Ultra Mode and Full HD (1080p @60Hz 24bpp) Up to 180m (590ft) Compliance HDBaseT 1.0 Video Max. Resolution 4K@60Hz (4:2:0) and 4K@30Hz (4:4:4) Compliance Supports HDMI 2.0 and HDCP 1.4 RS-232 Extension Baud Rate 300 to 115,200 Analog Audio Max Level 1 Vrms THD + Noise 0.03% @1kHz at nominal level Controls Front Panel Front panel buttons: input select, volume, EDID, IR Indication LEDs: input select, EDID type, outputs Rear Panel RS-232 device control RS-232 remote control via HDBT ports IR remote control via HDBT ports Ethernet DIP-switches Supported PC Web Browsers Windows 7 and Higher Internet Explorer (32/64 bit) version 10 Firefox version 30 Chrome version 35 MAC Chrome version 35 Chrome version 63.0.3239.84 Firefox version 30 Firefox version 57.0.2 Safari version 7 Minimum Browser Window Size 1024 x 768 when in full screen mode Power Consumption 65VA Source 100-240V AC, 50/60Hz Environmental Conditions Operating Temperature 0° to +40°C (32° to 104°F) Storage Temperature -40° to +70°C (-40° to 158°F) Humidity 10% to 90%, RHL non-condensing Regulatory Compliance Safety CE, FCC Environmental RoHs, WEEE Enclosure Size 19” 1U Type Aluminum Cooling Fan ventilation General Net Dimensions (W, D, H) 43.6cm x 23.7cm x 4.4cm (17.2” x 9.3” x 1.7”) Shipping Dimensions (W, D, H) 52.5cm x 33cm x 10.7cm (20.7” x 13” x 4.2”) Net Weight 2.5kg (5.5lbs) approx. Shipping Weight 3.2kg (7.1lbs) approx. Accessories Included Power cord, rack ears Optional For optimum range and performance use the recommended USB, Ethernet, serial and IR Kramer cables available at www.kramerav.com/product/VM-218DTxr Specifications are subject to change without notice at www.kramerav.com