Text of Crown M Series Operation Manual

Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your

local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operatio

M Series Power Amplifiers

page 2 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with a dry cloth. 7) Do not block any ventilation openings. Install in accor- dance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers)
M Series Power Amplifiers Operation Manual DECLARATION of CONFORMITY Crown International, Inc. Sue Whitfield 574-294-8289 [email protected] European Representative's Name and Address: Nick Owen 35, Bassets Field Thornhill Cardiff. South Glamorgen CF14 9UG United Kingdom Equipment Type: Commercial Audio Power Amplifiers Family Name: CE Model Names: M120, M240 EMC Standards: EN 55103-1:1996 Electromagnetic Compatibility - Product Family St
M Series Power Amplifiers page 4 Important Safety Instructions .......................................................2 Declaration of Conformity ............................................................3 1 Welcome ....................................................5 1.1 Features ...........................................................................5 1.2 How to Use This Manual ..........................................
M Series Power Amplifiers Operation Manual 1 Welcome The M Series of power amplifiers from Crown® represents a new era in affordable, quality power amplification. The line consists of two models in a uniform, rugged chassis, incorpo- rating the best of tried-and-true design princi- ples and innovative features. Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power levels. They must be treated with
M Series Power Amplifiers page 6 2.1 Unpack Your Amplifier Please unpack and inspect your amplifier for any damage that may have occurred during transit. If damage is found, notify the transpor- tation company immediately. Only you can ini- tiate a claim for shipping damage. Crown will be happy to help as needed. Save the shipping carton as evidence of damage for the shipper’s inspection. We also recommend that you save all packing mater
M Series Power Amplifiers Operation Manual 2.4 Choose Input Wire and Connectors Crown recommends using pre-built or professionally wired, bal- anced line (two-conductor plus shield), 22-24 gauge cables and connectors. Depending upon which amplifier input you choose, you should use either 3-pin male XLR connectors, TRS phone connectors, or terminal forks at the amplifier inputs. Unbalanced line may also be used but may result in noise over long cable
M Series Power Amplifiers page 8 2.6 Wire Your System 2.6.1 Stereo Mode Typical input and output wiring is shown in Figure 2.7. INPUTS: Connect input wiring for both channels. OUTPUTS: Maintain proper polarity (+/–) on output connectors. Connect Channel-1 loudspeaker’s positive (+) lead to Channel-1 positive (red) terminal of amp; repeat for negative (–). Repeat Channel 2 wiring as for Channel 1. How to Parallel the Inputs in Stereo
M Series Power Amplifiers Operation Manual 2.6.2 Bridge-Mono Mode Typical input and output wiring is shown in Figure 2.9. Set the Mode Switch to Bridge. INPUTS: Use only the Channel-1 input connec- tor. NOTE: Crown provides a reference of wiring pin assignments for commonly used connector types in the Crown Amplifier Application Guide available at www.crownaudio. OUTPUTS: If you are using the 5-way binding posts, connect the speaker across the red b
M Series Power Amplifiers page 10 2.7 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifier; then, plug the other end of the cordset to the AC mains. WARNING: The third prong of this connector (ground) is an important safety feature. Do not attempt to disable this ground connec- tion by using
M Series Power Amplifiers Operation Manual 3.1 Precautions Your amplifier is protected from internal and exter- nal faults, but you should still take the following precautions for optimum performance and safety: 1. Before use, your amplifier first must be config- ured for proper operation, including input and output wiring hookup. Improper wiring can result in serious operating difficulties. For information on wiring and configuration, please consu
M Series Power Amplifiers page 12 Clip Fault Signal Clip Fault Signal Power Power 11 22 Reset Reset I Clip Fault Signal Clip Fault Signal WARNING AVIS - AVERTISSEMENT - ó RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. ENERGIE ELECTRIQUE DANGEREUSE VIOR LA NOTICE DE FONCTIONNEMENT. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN OUTPUT ASSIGNMENT CH2

Crown Amplifier Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
CDi 2000

#1ZPU66: CDi 2000 Amplifier Architectural & engineering specifications

1 0.07 Mb 46 11 13-08-2026
CL1

CL1 (Amplifier ePDF Guide, #9UH65T)

2 0.4 Mb 1438 216 21-06-2026
ct16s

ct16s Operation manual - PC6434

28 1058 212 16-05-2026
Contractor Series

Amplifier #57FO77

44 376 68 10-05-2026

Amplifier: Similar Manuals