Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your
local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situation which may arise during installation, operatio
M Series Power Amplifiers
page 2
1)
Read these instructions.
2)
Keep these instructions.
3)
Heed all warnings.
4)
Follow all instructions.
5)
Do not use this apparatus near water.
6)
Clean only with a dry cloth.
7)
Do not block any ventilation openings. Install in accor-
dance with the manufacturer’s instructions.
8)
Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers)
M Series Power Amplifiers Operation Manual
DECLARATION of CONFORMITY
Crown International, Inc.
Sue Whitfield
574-294-8289
[email protected]
European Representative's Name and Address:
Nick Owen
35, Bassets Field
Thornhill
Cardiff. South Glamorgen
CF14 9UG United Kingdom
Equipment Type: Commercial Audio Power Amplifiers
Family Name: CE
Model Names: M120, M240
EMC Standards:
EN 55103-1:1996 Electromagnetic Compatibility - Product Family St
M Series Power Amplifiers page 4
Important Safety Instructions .......................................................2
Declaration of Conformity ............................................................3
1 Welcome ....................................................5
1.1 Features ...........................................................................5
1.2 How to Use This Manual ..........................................
M Series Power Amplifiers Operation Manual
1 Welcome
The M Series of power amplifiers from Crown®
represents a new era in affordable, quality
power amplification. The line consists of two
models in a uniform, rugged chassis, incorpo-
rating the best of tried-and-true design princi-
ples and innovative features.
Modern power amplifiers are sophisticated
pieces of engineering capable of producing
extremely high power levels. They must be
treated with
M Series Power Amplifiers page 6
2.1 Unpack Your Amplifier
Please unpack and inspect your amplifier for
any damage that may have occurred during
transit. If damage is found, notify the transpor-
tation company immediately. Only you can ini-
tiate a claim for shipping damage. Crown will
be happy to help as needed. Save the shipping
carton as evidence of damage for the shipper’s
inspection.
We also recommend that you save all packing
mater
M Series Power Amplifiers Operation Manual
2.4 Choose Input Wire and Connectors
Crown recommends using pre-built or professionally wired, bal-
anced line (two-conductor plus shield), 22-24 gauge cables and
connectors. Depending upon which amplifier input you choose,
you should use either 3-pin male XLR connectors, TRS phone
connectors, or terminal forks at the amplifier inputs.
Unbalanced line may also be used but may result in noise over
long cable
M Series Power Amplifiers page 8
2.6 Wire Your System
2.6.1 Stereo Mode
Typical input and output wiring is shown in
Figure 2.7.
INPUTS: Connect input wiring for both channels.
OUTPUTS: Maintain proper polarity (+/–) on
output connectors.
Connect Channel-1 loudspeaker’s positive (+)
lead to Channel-1 positive (red) terminal of amp;
repeat for negative (–). Repeat Channel 2 wiring
as for Channel 1.
How to Parallel the Inputs in Stereo
M Series Power Amplifiers Operation Manual
2.6.2 Bridge-Mono Mode
Typical input and output wiring is shown in
Figure 2.9.
Set the Mode Switch to Bridge.
INPUTS: Use only the Channel-1 input connec-
tor.
NOTE: Crown provides a reference of wiring pin
assignments for commonly used connector
types in the Crown Amplifier Application Guide
available at www.crownaudio.
OUTPUTS: If you are using the 5-way binding
posts, connect the speaker across the red b
M Series Power Amplifiers page 10
2.7 Connect to AC Mains
Connect your amplifier to the AC mains power
source (power outlet) with the supplied AC power
cordset. First, connect the IEC end of the cordset to
the IEC connector on the amplifier; then, plug the
other end of the cordset to the AC mains.
WARNING: The third prong of this connector
(ground) is an important safety feature. Do
not attempt to disable this ground connec-
tion by using
M Series Power Amplifiers Operation Manual
3.1 Precautions
Your amplifier is protected from internal and exter-
nal faults, but you should still take the following
precautions for optimum performance and safety:
1.
Before use, your amplifier first must be config-
ured for proper operation, including input and
output wiring hookup. Improper wiring can
result in serious operating difficulties. For
information on wiring and configuration, please
consu
M Series Power Amplifiers page 12
Clip
Fault
Signal
Clip
Fault
Signal
Power
Power
11
22
Reset
Reset
I
Clip
Fault
Signal
Clip
Fault
Signal
WARNING
AVIS -
AVERTISSEMENT -
ó
RISQUE DE CHOC ELECTRIQUE - NE PAS
OUVRIR.
ENERGIE ELECTRIQUE
DANGEREUSE VIOR LA NOTICE DE FONCTIONNEMENT.
TO REDUCE THE RISK OF FIRE OR
ELECTRICAL SHOCK, DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
OUTPUT ASSIGNMENT
CH2
Crown Amplifier Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
CDi 2000 |
#1ZPU66: CDi 2000 Amplifier Architectural & engineering specifications |
1 | 0.07 Mb | 46 | 11 | 13-08-2026 |
CL1 |
CL1 (Amplifier ePDF Guide, #9UH65T) |
2 | 0.4 Mb | 1438 | 216 | 21-06-2026 |
ct16s |
ct16s Operation manual - PC6434 |
28 | 1058 | 212 | 16-05-2026 | |
Contractor Series |
Amplifier #57FO77 |
44 | 376 | 68 | 10-05-2026 |