NEUTRIK NAC3MX-W Operating & Assembly Instruction

Text of the manual

OPERATING & ASSEMBLY INSTRUCTION

20 250 P S E JET 16 250 20 250 NAC3MX-W Place the chuck over the cable. Prepare the cable as shown. D B. ASSEMBLY INSTRUCTION A. OPERATING INSTRUCTION [0.32"] 8 mm [0.787”] 20 mm [0.9”] PE 23 mm Separate the housing from the bushing (cable remain in bushing) B C 20 250 P S E JET 16 250 20 250 NAC3MX-W Approval based: Rating: Cable Type: Strain Relief: Cable O.D.: VDE EN 60320-1/EN60320-2-2 250 V ac / 16 A 2 H05VV-F3G 1.0 mm , Length max. 2 m 2 H05VV-F3G 1.5 - 2.5 mm H07RN-F3G 1.5 mm2 White chuck 6.0 - 12.0 mm UL UL 498 / CSA C22.2 No. 182.3 250 V ac / 20 A SJTOW, SJOOW 3 x 12 AWG White chuck 6.0 - 12.0 mm C [0.32"] 8 mm [0.787”] 20 mm [0.9”] PE 23 mm VDE (EN 60320-1/EN60320-2-2) UL (UL 498 / CSA C22.2 No. 182.3) 40 - 50 mm Recommendation: Wire Pulling Lubricant - LUB-I/0.95 TM from 3M i A Insert cable into the bushing and housing. Note: “Apply cable pulling lubricant to cable jacket.” Connector Assignment: APPLIANCE APPLIANCE INLET APPLIANCE OUTLET INLET OUTLET COMBINATION NAC3PX NAC3MPX NAC3FPX NAC3FPX-ST 20 250 P S E JET 20 250 P S E JET 16 250 20 250 NAC3MX-W 20 250 P S E JET 16 250 20 250 NAC3MX-W 20 250 P S E JET Power IN Power OUT Power OUT Power IN NAC3MX-W (Plug connector) NAC3FX-W (Connector) NAC3FX-W (Connector) NAC3MX-W (Plug connector) Application: The powerCON TRUE1 system is certified as a connector with breaking capacity according IEC 60320, VDE 0625. It is intended for use as an appliance coupler and interconnection coupler. It serves to supply power to an appliance and from an appliance to other equipment. To be installed by qualified person only.

Torque Value 0.7 Nm

5. Torque Value 2.0Nm PRESS FIRMLY Torx size T8 1. 2. 4. Wrench size 13 mm 6. 3. Important: Push and turn simultaneously. FOR DISASSEMBLY - OPEN TWIST LOCK! 1. Press with screw driver to unlock 2. Turn bushing 360°. 3. Repat step 1 + 2 until bushing is unscrewed. 1. 2. CAUTION To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.). LIECHTENSTEIN 20 250 P S E JET G E F Important: Align rubber key and latch. Insert the wires into the terminals and fasten the screw with Torx size T8. Wiring VDE UL L brown black Þ N blue white Þ green / yellow green Þ Slide the chuck onto the insert (1) and then both together into housing (2). Important: Align the chuck and insert by positioning the nose into the keyway. Slide the bushing up the cable and tighten it with the tool as shown. Important: Yellow O-ring to hide to achieve IP protection (6). (Tool available: Art. No. HTAC) FORCE Draft. Nr.: BDA 380 Update: 21.12.2017 Data subject to change without prior notice. 2017 NEUTRIK . ALL RIGHTS RESERVED. NEUTRIK and powerCON is a registered trademark. I I ® ® ® © NEUTRIK AG LI T: +423 / 237 24 24 F: +423 / 232 53 93 NEUTRIK USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202 ( ) NEUTRIK UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439 NEUTRIK Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830 NEUTRIK France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511 NEUTRIK Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796 NEUTRIK Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052 NEUTRIK India Pvt. Ltd. IND T: +91 / 982 05 43 424 F: +91 / 22 26163 540 SAFETY WARNING For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.

Other Cables and connectors Manuals