Document No: ICM-IOM

Date: 08/24/20 PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW Mars Air Curtains are designed to cover door openings, providing both temperature control/ environmental separation and flying insect control, when the building’s doors are opened. Typical installation heights are: Phantom 10 Series (Environmental Separation up to 12’ / Flying Insect Control up to 10’), and Phantom 12 Series (Environmental Separation up to 16’ / Flying Insect Control up to 14’). The units are typically suspended from the ceiling and hidden inside the false roof. They can also be wall mounted using special brackets. The units are ETL Listed, Canada and US, for either an inside or outside mount. Heated units must be mounted on the inside or the protected side of the opening. The motors used in the Phantom 10 and Phantom 12 series are 1/2 HP and 1 HP, respectively. The Phantom Series come standard with an air intake screen(s). GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Only qualified personnel should install this product. Installing personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following. A. Always disconnect, lock and tag power source before installing or servicing product. B. Installation work or electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. The combustion airflow needed for safe operation of fuel burning equipment in the area may be affected by the product’s operation. Follow the heating equipment manufacturer’s guideline and safety standards, such as those published by the National Fire Protection Agency (NFPA), the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. D. When cutting or drilling into a wall or ceiling, be careful not to damage electrical wiring and other hidden utilities. WARNING When servicing the product, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing.

RECEIVING AND INSPECTION

Upon receiving the product, check to make sure all items are accounted for by referencing the Bill of Lading to ensure all items were received. Inspect each carton for shipping damage before accepting delivery. Notify the freight carrier if any damage is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all copies of the Bill of Lading which is countersigned by the delivering carrier. A Carrier Inspection Report should be filled out by the carrier upon arrival and a report given to the Traffic Department. If damaged upon arrival, file a claim immediately with the carrier. Any physical damage to the unit after acceptance is not the responsibility of Mars Air Systems. UNPACKING Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved. INSTALLATION Typical Mounting – Wall or Ceiling Mounted Horizontally Above the Door Opening 1. Gently remove all packaging materials, hardware, and all other accessories from interior of unit prior to operating. Severe unit damage will occur if these items are not removed prior to operation. 2. The intake screen can be opened by removing the two screws on the bottom of the unit. The screen can be removed from the unit by pulling the spring-loaded piano hinges. (FIG. 1) 3. All Phantom series have the Motor Fan Assembly (MFA) shipped internally mounted. 4. All units are equipped with (4) 3/8’’ threaded inserts on top for overhead installation (FIG. 2) 5. Determine the exact mounting locations to suspend the unit above the ceiling so that the unit is centered and parallel with the door opening. Use (4) threaded rods to suspend the enclosure to the ceiling. Note: When installed in the ceiling above the door, the air curtain must be moved 3/8” away from the wall for every 1" above the door height. 6. If applicable, extended wall mounting brackets are available for attaching the unit to a wall. 7. If applicable, for tandem installation (units longer than 72”) of products mounted side by side, allow no more than 6” between the two units. Note that (4) sets of threaded rods are used to suspend each unit to the ceiling or center mounting brackets are to be used for joining and top mounting tandem units. 8. Mount the product such that the discharge is flush with the ceiling. 9. All wires must be connected internal of the unit and some knockouts are provided. However, it may be necessary to create your own knockout, as required. 10. The unit must be wired per NEC and local codes. FIG 1 FIG. 2 Electrical Field Wiring 1. For electric models, reference the Heated Products Supplement. 2. The unit and any optional accessories must be wired with the proper voltage to the junction box per the wiring diagram. (FIG. 3, unheated products only) 3. All 3 phase motors are bi-directional, which means they can rotate in either direction. Follow directional arrows on the blower wheel housings for proper rotation. If the motor is rotating incorrectly, switch two of the 3 phase power or motor leads and the motor will rotate the opposite direction. Make sure all motors are turning in the same and proper direction. (FIG. 3) WARNING Precaution should be taken in explosive atmospheres.

For accessory installation, reference Accessory

Installation Supplement. For heated products, reference Heated Products Supplement. START-UP This product has been assembled and tested at the factory prior to shipping. The following procedures should be performed to assure its performance. Before continuing with the start-up, it is important to recognize the safety controls furnished with the unit. WARNING Prevent hazard of electrical shock. More than one disconnect switch may be required to de-energize this product. WARNING The following items must all be completed by a qualified installer and checked off when completed A. Re-check that the product has been installed properly and is level and secure. B. Check all terminal screws are tight and field wiring is connected in accordance to National Electrical Code and wired per the enclosed wiring diagram. For electric heated models, ensure that the coils are secured and not touching each other on any metal surface. C. Verify proper voltage prior to powering the product. (See product label for reference). D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G. Verify voltage to the product once more and turn power on. H. Regardless of whether the product is mounted on the inside or outside of the door opening, set the air directional vanes in the discharge nozzle slightly outward to approximately 10-15° towards the outside, or the wind load. (FIG. 4). I. For products with control panels, turn the HOA (Hand- On-Auto) selector switch to “On” position and open the door to energize the product. For products without a control panel or an On/Off switch, open the door to energize the product. J. If heated products are installed, reference Heated Products Supplement. K. For three phase units, verify direction of rotation of blower wheels (note direction arrows on the blower wheel housing). Correct if needed by changing polarity of three phase power. FIG. 4

Routine maintenance is required to keep this product

operating at its peak performance and efficiency. Over time, the housing, air intake grille, air intake filter, blower wheels and motor(s) will accumulate a build up of dust, debris and other residue. It is imperative to keep these components clean. Failure to do so will not only lower operational efficiency and performance, but also reduce the useful life of the product. The time between cleanings depends on the application, location, and daily hours of use. On average, under normal use conditions, the product should require a thorough cleaning once every six (6) months. To clean the product, perform the following: 1. Verify the product has been disconnected from the power source. 2. Use a damp cloth and either a warm mild soapy water solution or bio-degradable degreaser, to wipe down the exterior components of the housing. 3. To access the interior of the product, remove the air intake grille(s) and/or air intake filter(s). This is accomplished by removing the screws on the face of the air intake grille(s)/filter(s) and releasing the grille by pulling on the spring hinge. 4. Thoroughly clean the air intake grille(s) and clean or replace the intake filter(s). 5. Thoroughly wipe down the motor, blower wheels and blower wheel housings. Be careful not to spray the motor with a water hose. 6. The motor(s) require no additional lubrication. They are permanently lubricated and feature double sealed ball bearings. 7. To re-install the product, reverse the procedures above. 8. Reconnect the power source to the product. 9. If you have any questions regarding the maintenance of the product, contact the manufacturer. SPECIAL APPLICATIONS Outdoor Installation For outdoor unit special consideration may be required for enclosure, motor, wheel, and other components to minimize damage caused by exposure to the outdoor elements. Contact factory for special construction and costing. Freezer and Cooler Installation Air curtain must be mounted on the warm side for optimal performance. Variable Frequency Drive (VFD) is strongly recommended to control the air curtain air flow velocity at the floor level. High humid areas may require de-humidifier or additional defrost cycle to minimize condensation and freezing for freezer applications. We recommend the air curtain unit to not replace doors but work in conjunction with door opening sequence cycle. Contact factory for details. DISCLAIMER Mars reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. L. VERY IMPORTANT Using a clamp meter, measure the amperage to each motor and ensure that they do not exceed the amperage listed on the product label. M. If applicable, adjust the air intake grille(s) such that the output air stream reaches the floor. For temperature control and environmental separation applications, the air stream should reach the floor with sufficient strength to create an air seal around the door opening without creating turbulent mixing of the inside and outside air. If applicable, adjust the air intake grille(s) such that the output air stream reaches the floor. For flying insect control applications, the air stream should reach the floor with maximum strength. If after proper installation and adjustment, the product appears to be producing too little or too much air for the application, contact the manufacturer. WARNING To reduce the risk of fire, electrical shock, or injury to persons, observe the following: A. Maintenance is to be performed only by qualified personnel who are familiar with local codes and regulations and are experienced with this type of product. B. Before servicing or cleaning the product switch power off at service panel and lock service panel to prevent power from being switched “ON” accidentally.