True RMS 1000V Digital Multimeter

w/Temperature 1000V CAT II 600V CAT III KANE515 ® KANE515 ® www. .com [email protected] 1.800.561.8187

TABLE OF CONTENTS

FUNCTIONS ................................................................................................................................................. 3 FEATURES .................................................................................................................................................... 3 GENERAL SPECIFICATIONS .................................................................................................................... 3 CATEGORY DEFINITIONS .......................................................................................................................... 3 IMPORTANT SAFETY WARNINGS ......................................................................................................... 4 CLEANING .................................................................................................................................................... 4 OVERVIEW .................................................................................................................................................. 5 SYMBOLS .................................................................................................................................................... 6 OPERATING INSTRUCTIONS AC/DC Voltage: <1000V AC/DC ....................................................................................................6 Resistance: <40MΩ ........................................................................................................................... 7 Continuity ........................................................................................................................................... 7 Diode ................................................................................................................................................... 8 Capacitance ......................................................................................................................................... 8 ..........................................................................................................9 AC/DC Milliamps: 400mA .............................................................................................................9 AC/DC Amps: <10A ......................................................................................................................... 10 Temperature C˚/F˚ ............................................................................................................................ 10 Test Lead Notes ................................................................................................................................ 11 Battery Replacement ....................................................................................................................... 11 FCC/IC INFORMATION ............................................................................................................................ 12 WARRANTY ................................................................................................................................................ 12 DISPOSAL .................................................................................................................................................. 12 STORAGE .................................................................................................................................................. 12 www. .com [email protected] 1.800.561.8187

• 1000V AC/DC

• 10A AC/DC • Resistance 40MΩ • Diode test • Audible continuity • Capacitance 9999µF • Temperature -328˚ to 2462˚F (-200˚ to 1350˚C) • Microamps • Milliamps • Auto/Manual ranging • True RMS • Auto power off • Min/Max • Hold • 1 ms Fast response Min/Max • Low battery indicator • Rubber boot • Test lead holders • Kick stand • High resolution backlit display • Fused test lead inputs • Auto selection GENERAL SPECIFICATIONS • Operating Temperature: 32˚ to 122˚F (0˚ to 50˚C) • Storage Temperature: -44˚ to 122˚F (-20˚ to 50˚C) • Operating Humidity: <75% max. • Operating Altitude: 6561 ft (2000m) • Display: 6,000 • Backlight: Yes • Over-range: “OL” is displayed • Dimensions: 6.50” x 3.31”x 2.28” • Item Weight: 15.2 oz • Calibration: Recommended annually • CAT Rating: CAT III 600V/CAT II 1000V • Certifications: • Battery Type: (AA) 2 • Test Leads: CAT III test leads • Accuracy: ± (% of reading + # of least significant digits) Measurement Category Short-Circuit (typical) kAa Location in the building installation II < 10 Circuits connected to mains socket outlets and similar points in the MAINS installation III < 50 Mains distributions parts of the building IV > 50 Source of the mains installation in the building CATEGORY DEFINITIONS cETLus UL 61010-1:2012 3rd CE EN 61010-1:2010 3rd, IEC61010-2-033:2012 Ed.1, EN 61326-1:2013 FCC, RoHS Compliant, TOV protection, IP 42. 6’ Drop protection www. .com [email protected] 1.800.561.8187

IMPORTANT SAFETY WARNINGS

WARNING Read entire Safety Notes section regarding potential hazard and proper instructions before using this meter. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument. WARNING To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death. WARNING • Before each use, verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use this meter during electrical storms or in wet weather. • Do not use the meter or test leads if they appear damaged. • Ensure meter leads are fully seated and keep fingers away from the metal probe contact when making measurements. Always grip the leads behind the finger guards molded into the probe. • Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 60 DC or 25 AC RMS. Such voltages pose shock hazards. • To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. • Unless measuring voltage or current, shut off and lockout power before measuring resistance or capacitance. • Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) to prevent shock and arc blast injury where hazardous live conductors are exposed. • Always turn off power to a circuit or assembly under test before cutting, unsoldering or breaking the current path. Even small amounts of current can be dangerous. • Always disconnect the live test lead before disconnecting the common test lead from the circuit. • In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of victim’s apparent recovery. Electrical shock can cause unstable heart rhythms that may need medical attention. • If any of the following occur during testing, turn off the power source to the circuit being tested: arching, flame, smoke, extreme heat, smell of burning materials or discoloration or melting of components. WARNING Higher voltages and currents require greater awareness of physical safety hazards. Before connecting the test leads; turn off power to the circuit under test, set meter to the desired function and range; connect the test leads to the meter first, then connect to the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power immediately and recheck all settings and connections. WARNING This meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all recommended safety procedures that include proper lockout utilization and use of personal protective equipment that includes safety glasses, gloves and flame resistant clothing. CLEANING Periodically clean your meters’ case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components. www. .com [email protected] 1.800.561.8187

A. Apo: Auto power off after 30 minutes of use. Press

and hold the HOLD button while turning the meter on to disable Apo. B. Digital Backlit Display C. Range Button • Press to change from auto ranging to manual ranging. • Press repeatedly to select proper range. • Press and hold to return to auto range (AT will be displayed on screen). D. Min/Max Button • Press to enter MAX/MIN mode. AC/DC or change to manual ranging before pressing this button to enter MAX/MIN mode. • Press repeatedly to alternate between Maximum and Minimum readings. • Press and hold to return to live readings. E. Select Button: • Press to select AC, DC or Auto Selection in the • Press to select °C or °F in the Temperature function. F. Function Dial: Turns on meter and is used to select the function. G. Hold/Fast Button • Press to hold the reading on the display. Press again to return to live reading. • Press to enter Fast MAX/MIN mode in MAX/MIN mode. • Press again to return to normal MAX/MIN mode. H. Back Light Button: Press to on back light. Press again to turn off. Back light duration is 1 minute. I. Category Max Indicator: Maximum CAT Rating for fused input jacks. • Multifunction input port used for measuring: AC or DC volts, resistance, continuity, diode, capacitance µA,.mA, Amps, Temperature. • Use CATIII test leads or higher J. Recess for magnetic hanger K. Test Lead Holders L. Protective Rubber Boot M. Battery Cover (under protective rubber boot) N. Kick Stand O. Serial Number (under kick stand) KANE515 ® www. .com [email protected] 1.800.561.8187

AC/DC Voltage: <1000V AC/DC

AC VOLTS Ranges Accuracy Resolution Overload Protection 600mV to 1000V 45Hz to 500Hz 500Hz to 1kHz 0.1 mV to 1V 1000V ±(1.0% +3 dgts) ±(2.0% +3 dgts) Minimum sensitivity: 0.5V AC (auto selection mode) DC VOLTS Ranges Accuracy Resolution Overload Protection 600mV to 1000V ±(0.5% +3 dgts) 0.1 mV to 1V 1000V Minimum sensitivity: 0.5V DC (auto selection mode) WARNING • Use CATIII rated Test leads or higher. • Do not attempt to measure more than 1000V AC/DC. • Do not exceed 25 volts AC or 60 volts DC – RMS at either the common or multifunction input ports as measured from earth ground. Features: RANGE MIN/MAX HOLD SEL RANGE SEL Temp A True RMS MIN/MAX HOLD FAST V Apo µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 °F°C V Apo AT SYMBOLS Negative AC/DC Voltage or Current Auto-ranging Overload: Range Exceeded Auto power off Active Low Battery Hold/Capture Value Minimum measured value displayed Maximum measured value displayed Voltage A Amps µF Microfarad Microamps mA Milliamps Diode nF Nano Farads Ohms/Resistance Continuity Degrees Fahrenheit Degrees Celsius Fuse Warning or Caution Ground High Voltage Indication Dangerous Levels Auto Auto Selection KANE515 ® www. .com [email protected] 1.800.561.8187

600Ω to 6MΩ

±(0.8% +5 dgts) 0.1Ω to 0.001MΩ 600V 40MΩ ±(1.5% +5 dgts) 0.01MΩ Features: RANGE MIN/MAX HOLD WARNING • Do not measure resistance on a live circuit. Resistance: <40MΩ Open Circuit Voltage Audible Threshold Overload Protection Approx.: <1.0V Approx.: 40Ω 600V Features: MIN/MAX HOLD • Buzzer sounds at less than 40Ω. WARNING • Do not measure resistance on a live circuit. Continuity RANGE SEL Temp A True RMS MIN/MAX HOLD FAST V Apo µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 °F°C µA A mA °F°C Apo AT RANGE SEL MIN/MAX HOLD FAST V Apo A µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM505 µA A mA °F°C Apo KANE515 ® KANE515 ® www. .com [email protected] 1.800.561.8187

Open Circuit Voltage

Overload Protection Approx.: <3.0V DC 600V • Forward voltage drop if forward biased. • “OL” if reverse biased. Features: MIN/MAX HOLD BAD DIODE '0' Both directions (shorted) or V Apo V Apo Features: RANGE MIN/MAX HOLD Ranges Accuracy Resolution Overload Protection 10nF to 9999µF ±(3.0% +5 dgts) 0.01nF to 1µF 600V Capacitance Open Diode Displays "OL" Both directions RANGE SEL Temp A True RMS MIN/MAX HOLD FAST V Apo µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 °F°C µA A mA °F°C Apo V Forward Bias Displays approx. voltage drop RANGE SEL Temp A True RMS MIN/MAX HOLD FAST V Apo µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 °F°C A µA mA Apo AT nF Reverse Bias Displays "OL" WARNING: To avoid damaging the meter or euipment under test, safely discharge Capacitors before measuring capacitance. Large value capacitors should be discharged through an appropriate Resistance load. Use the DC Voltage function to confirm the capacitor discharge. KANE515 ® KANE515 ® www. .com [email protected] 1.800.561.8187

Keep hands behind test lead guards when measuring current levels.

Features: RANGE MIN/MAX HOLD SEL ACµA Ranges Accuracy Resolution Overload Protection ±(1.2% +5 dgts) 600mA /1000V Fast Fuse DCµA Ranges Accuracy Resolution Overload Protection ±(1.0% +3 dgts) 600mA /1000V Fast Fuse ACmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA ±(1.2% +5 dgts) 0.01mA to 0.1mA 600mA /1000V Fast Fuse Minimum sensitivity: 5mA AC (auto selection mode only) DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA ±(1.0% +3 dgts) 0.01mA to 0.1mA 600mA /1000V Fast Fuse Minimum sensitivity: 5mA DC (auto selection mode only) AC/DC Milliamps: 400mA RANGE SEL MIN/MAX HOLD FAST V Apo A µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM505 A µA mA µA Apo AT µ A RANGE SEL MIN/MAX HOLD FAST V Apo A µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM505 A µA mA mA Apo AT A m KANE515 ® KANE515 ® www. .com [email protected] 1.800.561.8187

Keep hands behind test lead guards when measuring current levels.

• Do not attempt to measure more than 10A AC. Features: RANGE MIN/MAX HOLD SEL AC AMPS Ranges Accuracy Resolution Overload Protection 6A to 10A ±(1.5% +5 dgts) 0.001A to 0.01A 11A/1000V Fast fuse Minimum sensitivity: 500mA AC (auto selection mode only) Frequency Bandwidth: 500Hz CAUTION: 20A overload for 30 seconds max. DC AMPS Ranges Accuracy Resolution Overload Protection 6A to 10A ±(1.2% +5 dgts) 0.001A to 0.01A 11A/1000V Fast fuse Minimum sensitivity: 500mA DC (auto selection mode only) CAUTION: 20A overload for 30 seconds max. °F Ranges Accuracy Resolution Overload Protection -328˚ to 999˚F ±(1.5% + 3.6˚F) 0.1˚F 600V 1000˚ to 2462˚F ±(1.5% + 3.0˚F) 1˚F °C Ranges Accuracy Resolution Overload Protection -200˚ to 999˚C ±(1.5% + 2.0˚C) 0.1˚C 600V 1000˚ to 1350˚C ±(1.5% + 2.0˚C) 1˚C • Press Select button to change scale between Fahrenheit and Celsius. Features: MIN/MAX HOLD SEL AC/DC Amps: <10A Temperature C˚/F˚ RANGE SEL MIN/MAX HOLD FAST V Apo A µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM505 A µA mA A Apo AT A RANGE SEL Temp A True RMS MIN/MAX HOLD FAST V Apo µA mAµA A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 °F°C µA A mA °F°C Apo AT Default = ˚F Press x1 = ˚C KANE515 ® KANE515 ® www. .com [email protected] 1.800.561.8187

Test Lead Notes

CATIII 1000V Measurement Locations • Ensure the test lead shield is pressed firmly in place. Failure to use the CATIV shield increases arc-flash risk. CATII 1000V Measurement Locations • CAT IV shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall outlets. Take care not to lose the shields. WARNING Test lead category protections apply only to test leads and should not be confused with the meter’s specific CAT rating. Observe the maximum category protection indicated on the meter the test leads are plugged into. Battery Replacement • When the batteries are too low for safe operation, the Low Battery indicator will display. 4mm 18mm 4mm 18mm S/N: AA AA S/N: www. .com [email protected] 1.800.561.8187

The KANE515 is warranted to be free from defects in materials and workmanship for a period of 1 year from the

date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at Kane’s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warranty. Any implied warranties, including but not limited to implied warranties of merchantability and for a particular purpose, are limited to the express warranty. Kane shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. DISPOSAL CAUTION: This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal. STORAGE Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the instrument to return to normal operating conditions before using it. NOTE: This device complies with Part 15 of the FCC Rules and CAN ICES-3(A). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. INFORMATION TO THE USER This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designedto provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to w hich the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. WARNING Any changes or modifications not expressly approved by the manufacturer, could void the user’s authority to operate equipment. FCC/IC INFORMATION Copyright © 2018 Kane Group Ltd. ®The KANE logo is a registered trademark of Kane Group Ltd. All Rights Reserved. www. .com [email protected] 1.800.561.8187