Intracom OSDR Installation Manual
Read Online
Read the Intracom OSDR Installation Manual online using the built-in PDF viewer.
Text of the manual
Radio (OSDR) platform
GDC-003/54
OSDR
19.7 km Markopoulou Ave., Peania, Athens, GR 19002
T +30 210 667 1000, F +30 210 667 1001
http://www.intracom-telecom.com
email (product support): [email protected]
The information contained in this document is subject to change without prior notice.
INTRACOM S.A. TELECOM SOLUTIONS, 2018. All rights reserved.
All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains
are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners.
This document is made available to the end users only for their internal use.
No part of this document nor any data herein may be published, disclosed, copied, reproduced,
redistributed by any form or means, electronically or mechanically, or used for any other purpose
whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS.
Information as well as drawings and specifications contained in this document are subject to change
without prior notice.
All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOM
SOLUTIONS and/or their respective owners.
Any rights not expressly granted herein are reserved.
Printed in Greece.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
-I-
Document Revision History
Previous Edition:
2.2
Current Edition:
3.0
Reasons of Change
M = Modified, A = Added, R = Removed
Details
New materials (M) (A)
New installation procedures (A)
• Sectoral 26/28/32 GHz antenna
• Sectoral 10.5 GHz antenna
• Parabolic antenna 10.5/26/28/32
GHz
• M20 gland
• Outdoor AC PoNE
• Indoor AC PoNE
• XPOL tool kit
Contents restructure (M)
Document optimization
Revised installation instructions (M)
• OSDR to sectoral/parabolic
antenna
• OSDR to panel antenna
• Panel antenna mounting kit
• ETH cable installation
• Optical cable installation
• Power injectors installation
• Sectoral antenna pole space
requirements
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
-III-
Equipment Disposal
Disposal of old electrical and electronic equipment (applicable through the
European Union and other European countries with separate waste collection
systems).
This symbol, found on this product and any of its parts or on its operating instructions
or on its packaging, indicates that electrical and electronic equipment may not be
disposed of as unsorted municipal waste. Instead, this product should be handed over
to applicable collection points for the recycling of electrical and electronic equipment.
By ensuring the correct disposal of this product, you will help prevent potential
negative consequences to the environment and human health, which could otherwise
be caused by inappropriate disposal of this product.
By recycling, reusing and other forms of recovery of old electrical and electronic
equipment you are making an important contribution to the conservation of natural
resources and to the protection of the environment.
For more information about the recycling of this product, please contact your local
municipal authorities, municipal waste disposal service or the store where you
purchased this product.
Απόρριψη παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών (ισχύει στην
Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα χωριστής
συλλογής απορριμμάτων).
Το σύμβολο αυτό, που απεικονίζεται πάνω στο προϊόν και σε τυχόν εξαρτήματα του
ή στο εγχειρίδιο οδηγιών του ή στη συσκευασία του, δείχνει ότι οι ηλεκτρικές και
ηλεκτρονικές συσκευές, μετά το πέρας της λειτουργίας τους, δεν θα πρέπει να
απορρίπτονται μαζί με τα αστικά απόβλητα. Αντίθετα θα πρέπει να παραδίδονται σε
κατάλληλα σημεία συλλογής για την ανακύκλωση των ηλεκτρικών και ηλεκτρονικών
συσκευών.
Διασφαλίζοντας τη σωστή απόρριψη αυτού του προϊόντος, συνεισφέρετε στην
πρόληψη πιθανών αρνητικών συνεπειών στο περιβάλλον και την ανθρώπινη υγεία,
οι οποίες θα μπορούσαν να προκληθούν από την μη ενδεδειγμένη απόρριψη του
προϊόντος.
Η ανακύκλωση, επαναχρησιμοποίηση και άλλες μορφές αξιοποίησης των παλαιών
ηλεκτρικών και ηλεκτρονικών συσκευών βοηθούν στη διαφύλαξη των φυσικών πόρων
και στην προστασία του περιβάλλοντος.
Για περισσότερες πληροφορίες σχετικά την ανακύκλωση αυτού του προϊόντος,
παρακαλούμε επικοινωνήστε με τις τοπικές δημοτικές αρχές, την υπηρεσία
αποκομιδής αστικών αποβλήτων ή το κατάστημα από το οποίο αγοράσατε το
συγκεκριμένο προϊόν.
Για περισσότερες πληροφορίες, μπορείτε να επικοινωνείτε με το Συλλογικό Σύστημα
Εναλλακτικής Διαχείρισης Αποβλήτων Ηλεκτρικού και Ηλεκτρονικού Εξοπλισμού
“Ανακύκλωση Συσκευών Α.Ε.” (www.electrocycle.gr).
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
-IV-
Declaration of Conformity
Hereby, Intracom S.A. Telecom Solutions declares that the products
OmniBASTM & WiBASTM are CE marked in compliance with the essential
requirements and other relevant provisions of the Radio Equipment Directive
2014/53/EU, Eco Design Directives 2009/125/EC, 2010/30/EU and with the
requirements of the RoHS directive 2011/65/EU.
The full text of the EU declaration of conformity is available at the
following URL: http://emc.intracom-telecom.com/en/start.htm
∆ήλωση Συμμόρφωσης
Με την παρούσα, η Intracom Α.Ε. Τηλεπικοινωνιακών Λύσεων δηλώνει ότι
τα προϊόντα OmniBASTM & WiBASTM φέρουν την σήμανση CE
συμμορφούμενο προς τις απαιτήσεις και τις λοιπές διατάξεις των οδηγιών
Radio Equipment Directive 2014/53/EU, Eco Design Directives
2009/125/EC, 2010/30/EU καθώς και με τις απαιτήσεις της οδηγίας RoHS
2011/65/EU.
Το πλήρες κείμενο της δήλωσης συμμόρφωσης (EU) είναι διαθέσιμο στην
ακόλουθη διεύθυνση URL: http://emc.intracom-telecom.com/en/start.htm
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
1
Table of Contents
1. Introduction ......................................................................................................................... 3
About this Document .......................................................................................................... 3
Safety Precautions ............................................................................................................. 5
2. Materials .............................................................................................................................. 9
OSDR ............................................................................................................................... 10
Antennas .......................................................................................................................... 11
Mounting Kits ................................................................................................................... 12
Cables .............................................................................................................................. 15
Cable Glands and Holder ................................................................................................. 18
Power Injectors................................................................................................................. 19
SFP .................................................................................................................................. 21
Ancillaries ......................................................................................................................... 22
Others .............................................................................................................................. 23
3. Before Starting the Installation ........................................................................................ 24
3.1. Radio Unit View ................................................................................................................ 25
3.2. Radio Unit Cabling ........................................................................................................... 28
Gigabit ETH cable for service Traffic, Inband Management and Powering ....................... 29
Fiber Optic cable for service Traffic and Inband Management / Gigabit Ethernet (S-FTP)
cable for service Powering ............................................................................................... 37
3.3. Installation Tools .............................................................................................................. 45
3.4. Site Prerequisites ............................................................................................................. 47
4. Installation Procedures ..................................................................................................... 51
4.1. Radio Unit and Antenna ................................................................................................... 52
Sectoral and Parabolic Antenna ....................................................................................... 52
Panel Antenna .................................................................................................................. 65
4.2. Radio Unit Grounding Cable ............................................................................................. 76
4.3. Radio Unit Ethernet (S-FTP) Cable .................................................................................. 77
4.4. Power Injector .................................................................................................................. 82
4.5. Radio Unit Optical Cable (Optional) .................................................................................. 83
4.6. Radio Unit Cable Holder ................................................................................................... 88
Appendix A: Adaptation Kit Installation .............................................................................. 91
Pole Installation ................................................................................................................ 91
Appendix B: Mounting Kit Wall Installation ......................................................................... 94
Wall Installation ................................................................................................................ 94
Appendix C: Power Injector Installation .............................................................................. 96
Outdoor DC PoNE ............................................................................................................ 97
Outdoor AC PoNE .......................................................................................................... 105
Table of Contents
2
Indoor AC POE............................................................................................................... 112
Appendix D: Cables Termination ....................................................................................... 114
Ethernet Cable ............................................................................................................... 115
Grounding Cable ............................................................................................................ 120
AC Power Supply Cable ................................................................................................. 123
Appendix E: Sectoral Antenna Pole Space Requirements ............................................... 126
10.5 GHz Antenna .......................................................................................................... 126
26/28/32 GHz Antenna ................................................................................................... 128
Appendix F: Receptacles Pin Out ...................................................................................... 130
Radio Unit ...................................................................................................................... 130
Outdoor DC PoNE .......................................................................................................... 132
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
3
1. Introduction
About this Document
Scope of
Document
The scope of this document is to provide detailed instructions on the
installation and cabling of OSDR (Outdoor Software-Defined Radio platform)
wireless product.
This document applies for installation of all available operation
modes: PtMP Hub(1), PtMP TS(2) and PtP Node(3).
Target
audience
This document is addressed to certified technicians with wireless equipment
knowledge and skills concerning the following:
• Outdoor Radio Unit Installation (pole installation).
• Antenna installation.
• Preparation & Termination of: Ethernet & Grounding cables.
• Laying and Installation of: Ethernet, Fiber Optic & Grounding cables.
• Testing Ethernet cables using Ethernet cable testers.
Reference
manuals
The reference manuals are listed below:
Item
Description
1
Lightning & Surge Protection for Intracom Telecom Radios – Installation
Practices.
2
OSDR Product Catalog.
3
OSDR System Description.
4
Lightning & Surge Protector (LSP) Datasheet.
5
WiBASTM-Connect Installation.
6
OSDR Commissioning.
Continued on next page
(1) WiBASTM OSDR Hub.
(2) WiBASTM OSDR Terminal Station (TS). For WiBASTM-Connect refer to item 5 of the Reference
manuals.
(3) OmniBASTM-OSDR.
About this Document, Continued
Conventions
This document applies to the following conventions:
• Arial Bold blue fonts are used for order codes.
• Arial Blue underline fonts are used for document references.
• Arial Bold black fonts are used for indicating important information or
paragraph header.
This symbol means DANGER. The purpose of this symbol is to warn
you that any wrong action can cause bodily injury or even death.
This symbol means CAUTION. The purpose of this symbol is to
prevent you from performing an action that might result in damage of
the equipment.
The purpose of this symbol is to protect you from unauthorized entry
to the site and damage your equipment.
A note calls your attention to important supplementary information.
A hint denotes helpful piece of advice or practical suggestion.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
5
Safety Precautions
RF EXPOSURE
Locally applicable national and international RF safety requirements must be
adhered to when installing the OSDR / antenna system.
Please refer to local regulatory authorities for advice on compliance.
As guidance, for an OSDR 10.5 / 26 / 28 / 32 GHz:
According to EN 50385 and the relative EU Directives (1999/519/EC -
general public environment & 2004/40/EC – occupational environment) the
OSDR / antenna, should be installed in a location such that it is not possible
for workers or members of the public, in the normal course of their work or
everyday activities, to gain access closer in front of the antenna than the
specified distances in the table below.
The values of the table are given for OSDR at max power and max gain 60
cm terminal antenna.
BAND (GHz)
DISTANCE (meters)
WORKER
PUBLIC
PtMP
Hub
PtMP TS or
PtP Node
PtMP
Hub
PtMP TS or
PtP Node
26 / 28 / 32
0.5
2.55
1
5.1
10.5
1.25
2.5
Continued on next page
Safety Precautions, Continued
General
• Do not install or operate this system in the presence of flammable gases or
fumes. Operating any electrical instrument in such an environment is a
safety hazard.
• Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may void the product
warranty and may expose the end user or the service provider to legal and
financial liabilities.
• INTRACOM S.A. TELECOM SOLUTIONS and its resellers or distributors
are not liable for injury, damage or violation of regulations associated with
the installation of outdoor units or antennas.
• Appropriate labeling should exist at points with high risk of contact with
hazardous voltage.
• A list with emergency phone numbers (e.g. medical assistance numbers)
should be hung at easy-to-view positions.
• Also, recommended are for safety purposes, a fire detection system and
fire extinguishers (installed at easy-to-access points) inside the installation
premises.
• This equipment must be permanently earthed for protection and functional
purposes.
• Changes or modifications to this equipment not expressly approved by
INTRACOM S.A. TELECOM SOLUTIONS or the party responsible for
compliance could void the user's authority to operate the equipment.
Working on the Building’s Roof
During stormy weather, do not perform any mechanical assembling or
antenna installation / alignment works on the building’s roof.
The metal structure of towers / masts is prone to lightning.
Equipment Access
Only trained, authorized personnel should have access to the
installed equipment.
The equipment premises is intended to be installed in restricted access.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
7
Safety Precautions, Continued
Proper Grounding Installation & Equipotential Bonding
Never power on OSDR equipment unless you have completed the
grounding installation.
There is risk of equipment failure and / or electrical shock.
Ensure that:
• The grounding system measures an appropriate path resistance as specified
by local regulations.
• An appropriate grounding bar (or terminal) exists at the proximity of each
equipment installation position.
• The equipment is intended to be installed in location only where the
equipotential bonding has been applied.
Local AC Power Source
Ensure that:
• Safety requirements require a single pole circuit-breaker to be employed
between the local power DC source and outdoor AC PoNE.
• The circuit breaker must disconnect the mains phase of the AC power.
• For circuit breaker requirements refer to Circuit breakers on page 49.
Local DC Power Source
Ensure that:
• Safety requirements require a single pole circuit-breaker to be employed
between the local power DC source and outdoor DC PoNE.
• The circuit-breaker must control (open / close) the negative (-) V pole of the
power supply.
• The positive pole (+) V of the Local DC Power Source, which the wire of DC
power cable is terminated on, is grounded.
• For circuit breaker requirements refer to Circuit breakers on page 49.
AC & DC Power Supply Cables
Ensure that:
• Power source cables must be tested for short circuits, open circuit or wrong
wiring before installed.
• The ground wire of the AC power source cable must be connected to the
protective earth (ground) point of the mains electricity installation.
Continued on next page
Safety Precautions, Continued
Proper Connection of Power Injector
Never connect the Gigabit Ethernet (S-FTP) cables coming from the OUT
receptacle of power injector to network switches / routers / laptops.
There is risk of network devices failure due to potential power that is carrying
inside the cable.
Connect the OUT receptacle of power injectors to electrical GbE port of radio
unit as described in current manual.
Proper Radio Unit Power Up
Do not plug / unplug:
The Ethernet cable to / from the radio unit when the power injector
operates (powering through power injector).
There is risk of radio unit failure.
Always ensure that the power supply source / power injector is OFF before
plugging / unplugging.
Laser Radiation
When using SFP, then the OSDR is a CLASS 1 laser product.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
9
2. Materials
Scope
This chapter describes all the available materials for OSDR installation.
Topics
The chapter includes the following topics:
Description
Page
OSDR
10
Antennas
11
Mounting Kits
12
Cables
15
Cable Glands and Holder
18
Power Injectors
19
SFP
21
Ancillaries
22
Others
23
Full outdoor software defined radio, 10.5/26/28/32
GHz, FDD, GbE.
Operation Modes: PtMP Hub, PtMP TS, PtP Node.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
11
Antennas
Antenna types
#
Photo
Description
A
Antenna, sectoral 900, integrated,
26/28/32 GHz.
Includes:
• Mounting kit.
• Greasing paste.
• Installation leaflet.
B
Antenna, sectoral 900, integrated,
10.5 GHz.
Includes:
• Mounting kit.
• Greasing paste.
• Installation leaflet.
C
Antenna, parabolic, 0.3 m, integrated,
10.5/26/28/32 GHz.
Includes:
• Mounting kit.
• Greasing paste.
• Installation leaflet.
D
Antenna(1), panel, 10.5 GHz.
For installation requires the following
order codes:
• OSDR-ANT-MNT (mounting kit).
• GRS-PST (greasing paste).
For antennas order codes please refer to item 2 of Reference
manuals on page 3.
(1) Extra bolts and leaflet concerns only WiBASTM-Connect installation.
Mounting kit for
panel antenna
Oder Code
Description
OSDR-ANT-MNT
Pole/Wall mounting kit for panel antenna 10.5 GHz (pole
diameter 48 mm up to 60 mm).
Pole adaptation
bracket for
panel antenna
Oder Code
Description
INST-ADAPT
Pole adaptation bracket for panel antenna 10.5 GHz (pole
diameter 61 mm up to 120 mm).
OSDR-ANT-MNT is required for mounting
panel antenna 10.5 GHz.
#
Items Description
Qty
Details
A
Hose clamp.
2
For pole diameter 101 mm up to 120 mm.
B
Hose clamp.
2
For pole diameter 61 mm up to 100 mm.
C
Bracket.
1
Pole adaptation bracket.
D
Washers.
4
M8 washers (DIN125A), stainless.
E
Screws.
4
M8x25 hex-headed screw (DIN933),
stainless.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
13
Mounting Kits, Continued
Hooks for panel
antenna
Oder Code
Description
OSDR-PL-ANT-KIT
Hooks for panel antenna 10.5 GHz.
Pole mounting
bracket for
outdoor DC
PoNE
Oder Code
Description
INST-PONE-PL
Mounting bracket for pole installation of PONE-OD-DC
power injector (pole diameter 50 to 120 mm / steel hose
clamp diameter 64 to 140 mm).
Pole mounting
bracket for
outdoor AC
PoNE
Oder Code
Description
INST-PONE-PL2
Mounting bracket for pole installation of PONE-OD67-AC
power injector (pole diameter 50 to 120 mm / steel hose
clamp diameter 64 to 140 mm).
2 x screws and lock washers are used. The
third set (screw and lock washer) is for spare
purpose.
Continued on next page
Mounting Kits, Continued
Pole hose
clamps
Stainless steel hose clamp for pole installation of ETH-SRG-OD68 lightning
surge protector (one ETH-SRG-OD68 requires 2 clamps).
The following table shows the available hose clamps:
Item
Order Code
Description
A
ST-CL64-140
∅ 64-140 mm, width = 14.2 mm.
For ∅ 48-100 mm pole diameter.
B
ST-CL102-178
∅ 102-178 mm, width = 14.2 mm.
For ∅ 75-149 mm pole diameter.
C
ST-CL172-248
∅ 172-248 mm, width = 14.2 mm.
For ∅ 150-229 mm pole diameter.
D
ST-CL242-318
∅ 242-318 mm, width = 14.2 mm.
For ∅ 230-300 mm pole diameter.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
15
Cables
RSSI cable
Order Code / Photo
Description
CAB-RSSI-BNC
RSSI cable, male BNC to 2 x banana
plugs, 75 Ω for measuring OSDR
receive signal level in volts (voltmeter is
required).
Grounding kit
Order Code / Photo
Description
GND-KIT16-OD
Grounding kit for OSDR and outdoor
AC PoNE. Includes:
• 2 x meter yellow/green grounding
cable, 16 mm2 stranded
• 450 V
• Heat shrinkable tube, black, d = 9.5
mm x 4.8 mm.
• 1 x M5 terminal lug for 16 mm2
grounding cable stranded
• 1 x M8 terminal lug for 16 mm2
grounding cable stranded
Grounding
cable
Order Code / Photo
Description
GND-CAB6-ID
Grounding cable, per meter,
yellow/green, 6 mm2, stranded, 450 V
for outdoor DC PoNE.
Ethernet S-FTP
cable
Order Code / Photo
Description
ETH-CAB-SFTP
Shielded Ethernet cable Cat5E (S-
FTP), 4 x 2 x AWG24, black, UV-rated,
per meter.
Continued on next page
Order Code / Photo
Description
A
AC-PWR-CAB
AC power bulk cable(1), 3 x 0.75 mm2, 0.6 / 1 kV,
stranded, UV-rated, industrial type, outdoor use,
per meter.
Used for powering of outdoor AC PoNE (PONE-
OD67-AC).
B
DC-PWR-CAB-2
DC power cable, 2 x 2.5 mm2, PVC, 1 KV,
outdoor use, per meter.
Used for powering of outdoor DC PoNE (PONE-
OD-DC).
Continued on next page
(1) AC connector (ST-CONN-AC) is required for cable termination.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
17
Cables, Continued
Fiber optic
cables
Prefabricated connectorized fiber optic cables for outdoor use, DX, 2 x
LC/PC-LC/PC, available in multi-mode (MM) & single mode (SM) in different
lengths.
#
Order Code
Cable Length (m)
A
FBROPTMM-025
25
B
FBROPTMM-050
50
C
FBROPTMM-100
100
D
FBROPTMM-150
150
E
FBROPTMM-200
200
F
FBROPTSM-025
25
G
FBROPTSM-050
50
H
FBROPTSM-100
100
I
FBROPTSM-150
150
J
FBROPTSM-200
200
Cable Glands and Holder
M20 and M25
glands and
holders
#
Order Code / Photo
Details
A
M20-GLAND
OSDR M20 gland for
Ethernet cable.
B
OSDR-HOLD-2
Cable holder for fastening
2 x M20-GNAND
(includes 2 x tie wraps:
L = 100 mm, D = 18 mm,
W = 2.5 mm).
C
M25-GLAND
OSDR M25 gland for
Fiber optic cable.
D
OSDR-HOLD-5
Cable holder for fastening
4 x M20-GNAND and 1 x
M25-GLAND
(includes 5 x tie wraps:
L = 100 mm, D = 18 mm,
W = 2.5 mm).
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
19
Power Injectors
Indoor power
injectors
#
Order Code / Photo
Description
A
POE-AC75-ID
Indoor AC POE – 75 W
(Wall installation materials are not
included).
B
POE-ID-AC72
Indoor AC POE – 72 W
(Wall installation materials are not
included).
C
POE-AC56-IDH
Indoor AC POE – 56 W
(Wall installation materials are not
included).
D
IDU-O4P
Indoor OmniBASTM-4P (provides
PoNE-enabled interfaces to up to 4 x
OSDR units through 4 x GbE
interfaces).
Power Injectors, Continued
Outdoor power
injectors
#
Order Code / Photo
Description
A
PONE-OD-DC
Outdoor DC PoNE – 60 W
• For wall installation the package
includes:
− 4 x screws and wall plugs.
− 1 x M4 grounding terminal (for
terminating 6 mm2 grounding cable
(GND-CAB6-ID)).
• For pole installation the INST-
PONE-PL is required.
B
PONE-OD67-AC
Outdoor AC PONE – 62.7 W
• For wall installation the package
includes:
− 1 x M5 grounding steel nut (for
terminating 16 mm2 grounding cable
(GND-KIT16-OD).
− 2 x M20 steel cable glands (for
Ethernet cable (ETH-CAB-SFTP)
with RJ-45 (ST-RJ45) connector).
− 1 x AC power connector (for
terminating AC power supply cable
AC-PWR-CAB).
− 2 x washers, screws and wall plugs.
• For pole installation the INST-
PONE-PL2 is required.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
21
SFP
Electrical SFP
module
Oder Code / Photo
Description
SFP-ELGFE-IN
Electrical SFP for 10/100/1000 Base-T operation.
Optical SFP
module
#
Order Code
Description
A
SFP-MM-500M
SFP, multi-mode, up to 500 m, 1.25 Gbit/s, 850 nm.
B
SFP-SM-10KM
SFP, single mode, up to 10 Km, 1.25 Gbit/s, 1310 nm.
C
SFP-SM-40KM
SFP, single mode, up to 40 Km, 1.25 Gbit/s, 1310 nm.
D
SFP-SM-80KM
SFP, single mode, up to 80 Km, 1.25 Gbit/s, 1550 nm.
Order Code / Photo
Description
A
CAB-TIE-UV
Cable tie, 500 x 12.5 mm, black, UV-resistant.
One tie is recommended per cable meter.
B
ST-RJ45
RJ-45 connector, shielded for S-FTP cable
termination (ETH-CAB-SFTP).
C
ETH-SRG-OD68
Outdoor lightning surge protector with IP68
ingress protection for Ethernet lines (one ETH-
SRG-OD68 protects one Ethernet line).
Grounding
An M4 grounding screw is pre-installed on the
device for connection with 16 mm2 grounding
cable. Can be combined with GND-KIT16-OD
(not included).
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
23
Others
Tool kit
Item
Order Code / Photo
Description
A
SEC-ANT-XPOL-KIT
Tool kit for adjusting the antenna verticality
with respect to the ground.
Tools
Item
Order Code / Photo
Description
A
CRIMP-TOOL-S
Hand crimping tool for RJ-45 connector
(ST-RJ45).
B
TOOL-M20
Optional tool for M20 gland.
Used for installation of:
• OSDR 2 x M20 glands side-by-side
• Outdoor AC power injector (PONE-
OD67-AC) M20 gland.
3. Before Starting the Installation
24
3. Before Starting the Installation
Scope
This chapter describes all the prerequisites that must be considered prior to
installing the OSDR equipment.
Topics
The chapter includes the following topics:
Description
Page
Radio Unit View
25
Radio Unit Cabling
28
Installation Tools
45
Site Prerequisites
47
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
25
3.1. Radio Unit View
Receptacles
#
Marking
Description
Use
A
GbE2
Gigabit Ethernet,
Electrical RJ-45
(100/1000 Base-T).
To connect Ethernet (S-FTP) cable
for traffic / inband management
and power via power injector.
B
FE
Fast Ethernet, RJ-45
(100 Base-T).
To connect Ethernet (S-FTP) cable
for outband management / power
via power injector.
PROTECT
To connect Ethernet (S-FTP) cable
for protection (OSDR Hub (1+1)).
C
-
-
Reserved for future use.
D
-
-
Reserved for future use.
E
GbE1
Gigabit Ethernet, SFP
cage.
To connect SFP module (electrical
/ optical) for traffic and inband
management.
Continued on next page
3. Before Starting the Installation
26
Radio Unit View, Continued
Label
#
Description
1
Product description.
2
Frequency band.
3
OSDR determination as Low or High in the link pair.
4
Duplex spacing (MHz).
5
Sub-band (01 up to 18).
6
Transmit frequencies.
7
Receive frequencies.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
27
Radio Unit View, Continued
Other points
#
Marking
Description
Use
A
-
Anchor point
To carry OSDR unit.
B
-
Wave guide
To install antenna feeder.
C
-
Clamps
To mount antenna.
D
-
Female threads for M5
screws.
To install mounting kit for panel
antenna.
E
GND
Enclosure grounding
terminal.
To connect 16 mm2 grounding
cable.
F
RSSI
Receive signal level
indication.
To connect the RSSI cable for
measuring receive signal in volts.
G
-
Female threads for
screws.
To install cable holder.
3. Before Starting the Installation
28
3.2. Radio Unit Cabling
Introduction
This topic describes the cabling overview, as follows:
Description
Page
Gigabit ETH cable for service Traffic, Inband Management and Powering
29
Fiber Optic cable for service Traffic and Inband Management / Gigabit
Ethernet (S-FTP) cable for service Powering
37
The following instructions refers to cabling overview without using any
additional device for lightning surge protection.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
29
Gigabit ETH cable for service Traffic, Inband Management
and Powering
Cable length
restriction
The Gigabit Ethernet (S-FTP) cable for service traffic, inband management
and external powering applies to the following restriction:
The maximum length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6),
between OSDR receptacle (GbE2) and customer network receptacle
cannot exceed 100 meters.
Continued on next page
3. Before Starting the Installation
30
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
AC POE
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (75W):
Marking
Cable Type
GbE#2 and OUT
Gigabit Ethernet (S-FTP) cable for traffic, inband
management and superimposed DC power.
IN
Gigabit Ethernet (S-FTP) cable for traffic and inband
management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2 for radio unit.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
31
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
AC POE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (72W):
Marking
Cable Type
GbE#2 and POE
Gigabit Ethernet (S-FTP) cable for traffic, inband
management and superimposed DC power.
LAN
Gigabit Ethernet (S-FTP) cable for traffic and inband
management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2 for radio unit and 6 mm2 for
POE.
Continued on next page
3. Before Starting the Installation
32
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
AC POE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (56W):
Marking
Cable Type
GbE#2 and OUT
Gigabit Ethernet (S-FTP) cable for traffic, inband
management and superimposed DC power.
IN
Gigabit Ethernet (S-FTP) cable for traffic and inband
management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2 for radio unit.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
33
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
DC PoNE
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an outdoor DC PoNE:
Marking
Cable Type
GbE#2 and Gbe#OUT
Gigabit Ethernet (S-FTP) cable for traffic, inband
management and superimposed DC power.
Gbe#IN
Gigabit Ethernet (S-FTP) cable for traffic and
inband management.
INPUT
DC power supply cable.
GND
Grounding cable 16 mm2 for radio unit and 6 mm2
for PoNE.
Continued on next page
3. Before Starting the Installation
34
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
DC PoNE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an outdoor AC PoNE:
Marking
Cable Type
GbE#2 and GbE#OUT
Gigabit Ethernet (S-FTP) cable for traffic,
inband management and superimposed DC
power.
GbE#IN,
Gigabit Ethernet (S-FTP) cable for traffic and
inband management.
AC-IN
AC power supply cable.
GND
Grounding cable 16 mm2.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
35
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
DC PoNE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor OmniBASTM 4W/8W:
Marking
Cable Type
GbE#2 and GbE/DC OUT
Gigabit Ethernet (S-FTP) cable for traffic,
inband management and superimposed DC
power.
GbE#5-6
Gigabit Ethernet (S-FTP) cable for traffic and
inband management.
INPUT
DC power supply cable.
GND
Grounding cable 16 mm2 for radio unit and
4 mm2 for OmniBASTM – 4W/8W.
PWR1
OmniBASTM – 4W/8W DC power supply cable.
Continued on next page
3. Before Starting the Installation
36
Gigabit ETH cable for service Traffic, Inband Management
and Powering, Continued
Cabling
overview using
DC PoNE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor OmniBASTM 4P:
Marking
Cable Type
GbE#1 (OmniBASTM-4P) and
GbE#2
Gigabit Ethernet (S-FTP) cable for traffic,
inband management and superimposed DC
power.
GbE#5, 6
Gigabit Ethernet (S-FTP) cable with Gigabit
Ethernet Electrical SFP module or Fiber Optic
cable with Optical SFP module for providing
traffic and inband management to customer
network equipment.
GND
Grounding cable 16 mm2 for radio unit and
4 mm2 for OmniBASTM – 4W/8W.
-48VDC
OmniBASTM – 4P DC power supply cable.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
37
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering
Fiber optic
cable length
restrictions
The following tables shows the maximum length of optical fiber cables in
combination with the SFP type:
Optical Fiber Cable Lengths combined with Gigabit Ethernet SFP:
Optical Fiber Cable Type
SFP Details / Order Code
Max Length (m)
Single mode
1000 Base-LX
5,000
1000 Base-LX10
(SFP-SM-10KM)
10,000
1000 Base-EX
(SFP-SM-40KM)
40,000
1000 Base-ZX
(SFP-SM-80KM)
80,000
OM1 (62.5/125) Multi-mode
1000 Base-SX
(SFP-MM-500M)
275
OM2 (50/125) Multi-mode
550
Continued on next page
3. Before Starting the Installation
38
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Gigabit
Ethernet (S-
FTP) cable
length
restriction –
when AC POE
is used
The Gigabit Ethernet (S-FTP) cable for service external powering applies to
the following restriction:
The maximum length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6),
between OSDR receptacle (GbE2 or FE) and power injector receptacle
(POE or OUT) cannot exceed 200 meters (1 x 200 meter cable).
For complete cabling overview refer to Cabling overview using AC
POE on page 39.
Gigabit
Ethernet (S-
FTP) cable
length
restriction –
when DC PoNE
is used
The Gigabit Ethernet (S-FTP) cable for service external powering applies to
the following restriction:
The maximum length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6),
between OSDR receptacle (GbE2 or FE) and power injector receptacle
(Gbe OUT/NMS OUT for PONE-OD-DC or DC OUT/MNG – GbE/DC OUT
for OmniBASTM-8W or GbE1/GbE2 for OmniBASTM-4P) cannot exceed 200
meters (requires 2 x 200 meter cables in parallel).
See below an example using PONE-OD-DC
For complete cabling overview refer to Cabling overview using DC
PoNE on page 42.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
39
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
AC POE
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (75W):
Marking
Cable Type
FE and OUT
Gigabit Ethernet (S-FTP) cable for superimposed DC
power.
GbE#1
Fiber Optic cable with Optical SFP module for traffic and
inband management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2 for radio unit.
External powering can be provided either by GbE2 or FE.
For GbE2 powering see Gigabit ETH cable for service Traffic, Inband
Management and Powering on page 29.
Continued on next page
3. Before Starting the Installation
40
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
AC POE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (72W):
Marking
Cable Type
FE and POE
Gigabit Ethernet (S-FTP) cable for superimposed DC
power.
GbE#1
Fiber Optic cable with Optical SFP module for traffic and
inband management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2 for radio unit and 6 mm2 for
POE.
External powering can be provided either by GbE2 or FE.
For GbE2 powering see Gigabit ETH cable for service Traffic, Inband
Management and Powering on page 29.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
41
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
AC POE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor AC POE (56W):
Marking
Cable Type
FE and OUT
Gigabit Ethernet (S-FTP) cable for superimposed DC
power.
GbE#1
Fiber Optic cable with Optical SFP module for traffic and
inband management.
AC INPUT
AC power supply cord.
GND
Grounding cable 16 mm2.
External powering can be provided either by GbE2 or FE.
For GbE2 powering see Gigabit ETH cable for service Traffic, Inband
Management and Powering on page 29.
Continued on next page
3. Before Starting the Installation
42
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
DC PoNE
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an outdoor DC PoNE:
Marking
Cable Type
GbE#2, FE,
NMS#OUT and
Gbe OUT
Gigabit Ethernet (S-FTP) cable for superimposed DC
power.
GbE#1
Fiber Optic cable with Optical SFP module for traffic and
inband management.
INPUT
DC power supply cable.
GND
Grounding cable (16 mm2 for radio and 6 mm2 for PoNE).
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
43
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
DC PoNE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor OmniBASTM 4W/8W:
Marking
Cable Type
GbE#2, FE,
GbE/DC OUT and
DC OUT/MNG
Gigabit Ethernet (S-FTP) cable for superimposed DC power.
GbE#1
Fiber Optic cable with Optical SFP module for traffic and inband
management.
INPUT
DC power supply cable.
GND
Grounding cable (16 mm2 for radio unit and 4 mm2 for
OmniBASTM – 4W/8W).
PWR1
OmniBASTM – 4W/8W DC power supply cable.
Continued on next page
3. Before Starting the Installation
44
Fiber Optic cable for service Traffic and Inband Management
/ Gigabit Ethernet (S-FTP) cable for service Powering, Continued
Cabling
overview using
DC PoNE,
continued
The following schematic shows a cabling overview of OSDR radio unit when
powering is through an indoor OmniBASTM 4P:
Marking
Cable Type
GbE#1 - GbE#2 (OmniBASTM-4P) &
GbE#2 - FE (OSDR)
Gigabit Ethernet (S-FTP) cable for
superimposed DC power.
GbE#1 (OSDR)
Fiber Optic cable with Optical SFP
module for traffic and inband
management.
GND
Grounding cable 16 mm2 for radio unit
and 4 mm2 for OmniBASTM – 4W/8W.
-48VDC
OmniBASTM – 4P DC power supply cable.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
45
3.3. Installation Tools
Prerequisites
It is installer responsibility to provide the tools for equipment installation.
Equipment
installation
Item
Tool / Photo
Description
1
Adjustable torque U-wrench tool (up to 29
mm opening and supporting max tightening
torque 40 Nm).
Used for tightening screws and nuts.
2
Adjustable torque wrench tool with bits
(supporting max tightening torque 20 Nm).
Used for tightening screws and nuts.
3
Set of allen keys.
Used for radio polarization change and
cable holder installation.
4
Digital inclinometer with magnetic base.
Used for sectoral antennas alignment
works.
5
13 mm wrench.
Used for sectoral antenna verticality works.
Continued on next page
3. Before Starting the Installation
46
Installation Tools, Continued
Cables
Termination
Type of cables to be terminated:
• Ethernet (S-FTP) cable.
• AC & DC power supply cables for outdoor power injectors.
• 6mm2 and 16 mm2 outdoor yellow/green grounding cables.
Item
Tool / Photo
Description
1
Blade.
2
Cable cutter.
3
Pliers (long nose).
4
See order code CRIMP-TOOL-S on page 23.
5
Ethernet cable tester.
6
Crimping tool for 6 mm2 and 16 mm2 grounding
cable.
7
Hot air gun.
8
Soldering iron.
9
Solder.
Specific works
Item
Tool / Photo
Description
1
Drill machine with 5 mm bit.
Used for wall installation of outdoor power
injectors.
2
See order code TOOL-M20 on page on page
23.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
47
3.4. Site Prerequisites
Site survey
Site survey should be done before start the installation taking in
consideration the following:
Premises information
• Site details (address, contact persons, GPS and/or map co-ordinates, etc.).
• Site access and storage information (means of transport, equipment
storage and lifting information, etc.).
• Site location maps.
Network planning
• Site Coordinates.
• LOS verification (Hub – TS).
• Rooftop information (height, status, access, dimensions, layout, etc.).
• Information about pre-existing indoor/ outdoor equipment.
• Available mounting space (on the buildings’ roofs) to reserve for the
installation of the outdoor equipment.
Site-specific information
• Mechanical specifications of masts/ towers (type, dimensions/ diameter,
material, exterior finishing, etc.).
• Location of appropriate grounding points (bar or terminals).
• Location of appropriate power supply distribution points.
• Location of cable conduits available for routing the cables.
• Location of the network port distributors.
• Total length of the cables required.
Continued on next page
3. Before Starting the Installation
48
Site Prerequisites, Continued
Preparation of
the installation
premises
• Access to the installation premises must be facilitated during the
installation period.
• Entrances must be large enough to enable the easy transportation of the
new equipment.
• The floor must be level, smooth and able to bear the load of the
equipment.
• The roof must be engineered to bear the weight of the service personnel
and the outdoor equipment.
Network port
distributors
• Suitable electrical network port distributor should be available.
• The exact location of the network port distributor, as well as the network
ports to reserve, should be known prior to installing the equipment.
• Also, all the reserved ports on the network port distributors should be
qualified and tested before realizing the network connections with the
equipment.
Power supply
cable routing
Routing of AC or DC power supply power cable should be implemented as
prescribed by the local regulations regarding outdoor electrical installations.
Cable conduits
Appropriate cable conduits should exist for the routing of installed cables.
Grounding
Ensure the following:
• To make a protective earth connection, use the grounding point located
close to the radio unit.
• A grounding point (designated GND) should be located close to the
mounting position of the radio unit (0 to 2 m).
• The grounding point must be connected to grounding cable at least 16
mm2 diameter.
• An appropriate, low-resistance grounding system as specified by the local
regulations is required.
• The equipment will be connected to this grounding point, via the supplied
grounding cable. This can provides only partial protection against
Lightning-induced power surges. For more information regarding
equipment protection against Lightning-induced power surges please refer
to Lightning & Surge protection.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
49
Site Prerequisites, Continued
Lightning &
Surge
protection
A: For Ethernet (S-FTP) Cables:
Lighting surge protection device (LSP) is required to minimize possibility of
equipment damage to any equipment connected to the unit from lighting
induced surges.
For LSP device installation refer to Reference manuals item 4 on page 3.
B: Power Supply Cables (for power injector):
A power surge protection device (PSP) is required to minimize possibility of
equipment damage from lightning induced surges or power supply surges.
For PSP device installation refer to Reference manuals item 1 on page 3.
For LSP and PSP details and instructions refer to Reference manuals item 1
on page 3.
Circuit
breakers
The following table provides the circuit breakers characteristics for powering
of power injectors:
Powering Type
Required Circuit Breaker
Powering via indoor AC PoE
• single-pole MCB 6 A
• 230 V AC (voltage rating)
• C-curve (for Industrial Applications)
Powering via outdoor DC PoNE
• single-pole MCB 6 A
• min 72 V DC (voltage rating)
• C-curve (for Industrial Applications)
Powering via outdoor AC PoNE
• single-pole MCB 6 A
• 230 V AC (voltage rating)
• C-curve (for Industrial Applications)
If the plug of power supply cord is intended to be the power disconnect
device of the equipment, arrange in the installation to connect the
equipment to a socket-outlet installed close to the power injector and
easily accessible.
Continued on next page
3. Before Starting the Installation
50
Site Prerequisites, Continued
Pole
installation
• The pole construction should be rust free and strong enough to handle the
weight and restrict movement due to air pressure.
• Should be perfectly perpendicular to allow correct alignment of the
antenna.
• The antenna mounting kit should roughly point to the direction of the
opposite unit (based on the site survey data).
• Each radio and antenna unit must be installed according to the radio
planning data for pole installation (height, degrees e.t.c).
• The outdoor equipment, inclusive of the radio transceiver(s) and
antenna(s), should be mounted on a mast or on a tower.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
51
4. Installation Procedures
Installation
procedure
overview
This chapter describes the mechanical installation and cabling of the OSDR
equipment.
The following tables shows with order all the necessary steps for installation
completion:
Action
Description
Page
Photo
1
Radio Unit and Antenna
52
2
Radio Unit Grounding Cable
76
3
Radio Unit Ethernet (S-FTP) Cable
77
4
Power Injector
82
5
Radio Unit Optical Cable (Optional)
83
6
Radio Unit Cable Holder
88
4. Installation Procedures
52
4.1. Radio Unit and Antenna
Sectoral and Parabolic Antenna
Introduction
Apply this procedure for installing the OSDR to sectoral/parabolic antenna.
For sectoral antennas the procedure includes the alignment steps,
also.
The antenna is capable to be installed in both side of the pole. The
following photos are indicative of the installation in the left orientation
of the sectoral/parabolic models.
Prerequisites
It is very important to mount the antenna exactly as described to
INSTALLATION INSTRUCTION LEAFLET (included in the antenna
package).
Tools and
materials
#
Description
Tools
• Adjustable torque U-wrench.
• Allen key.
Materials
OSDR and antenna.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
53
Sectoral and Parabolic Antenna, Continued
Procedure
To install the OSDR onto the sectoral/parabolic antenna and to perform
antenna alignment, proceed as follows:
Step
Action
1
The antenna installation should look as follows.
Continued on next page
4. Installation Procedures
54
Sectoral and Parabolic Antenna, Continued
Procedure,
continued
Step
Action
2
Remove antenna protection label from the feeder, as shown
below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
55
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
3
Radio unit and antenna should be adjusted for common polarization, as shown
below. If the LINK polarization is VERTICAL then the feeders should be remained,
as shown below:
If the LINK polarization is HORIZONTAL, use the allen key to loosen the four screws
at the waveguide port of the OSDR (do not remove the screws) and then TURN the
polarizer, as shown below:
How to change antenna polarization
refer to antenna installation leaflet.
Do not over tighten the screws. Apply maximum tightening torque 0.6 Nm.
The misalignment of slots between the movable part and the stationary part of
the radio waveguide port is intentional and does not indicate a problem.
Continued on next page
4. Installation Procedures
56
Sectoral and Parabolic Antenna, Continued
Procedure,
continued
Step
Action
4
Lubricate the O-ring with silicone grease, as shown below.
• For parabolic antenna continue to step 5.
• For sectoral antenna 26/28/32 GHz go to step 8.
• For sectoral antenna 10.5 GHz go to step 19.
5
Unlock the four clamps of the radio unit,, as shown below.
6
Mount the OSDR onto the antenna, as shown below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
57
Sectoral and Parabolic Antenna, Continued
Procedure,
continued
Step
Action
7
Lock and secure all four clamps according to the pattern below.
Details of Clamps closing
End of procedure for parabolic antenna.
For parabolic antenna alignment refer to item 6 of
Reference manuals on page 3.
Continued on next page
4. Installation Procedures
58
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
8
Perform the following actions:
A: Mount the tool onto the antenna radio wave feeder, as shown below.
B: Use the cross screwdriver to screw the bolts and
then fully tighten.
Do not over tighten.
Make sure no any gap between tool and antenna, as shown below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
59
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
9
Use the U-wrench key (13 mm) to loosen the 3 nuts, as shown below (do not
remove the nuts).
10
Install the OSDR onto the antenna as described to steps 5, 6 and 7.
Continued on next page
4. Installation Procedures
60
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
11
To correct the antenna verticality with respect to the ground, perform the following
actions:
A: Place the inclinometer, as shown below:
B: Rotate (left-right) the radio unit till the inclinometer digital indicator reaches 0
degrees.
12
Remove the OSDR.
13
Tighten the three M10 nuts (see step 9).
DO NOT remove the XPOL tool.
• Do not over tighten.
• For maximum tightening torque please follow the antenna installation leaflet
(available in package).
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
61
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
14
Install the OSDR onto the antenna as described to steps 5, 6 and 7.
15
To correct the elevation angle for matching with the RF planning data, perform the
following actions:
A: Place the inclinometer, as shown below.
B: Use the U-wrench tool to perform elevation adjustment, as shown below.
Perform adjustment till the inclinometer reaches the tilt provided by RF
planning.
C: All elevation nuts and bolts should be tightened.
• Do not over tighten.
• For maximum tightening torque please follow the antenna installation
leaflet (available in package).
Continued on next page
4. Installation Procedures
62
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
16
Remove the OSDR and the XPOL tool.
17
Install the OSDR onto the antenna as described to steps 5, 6 and 7.
18
Use the U-wrench tool to perform azimuth adjustment(1), as shown below.
• Do not over tighten.
• For maximum tightening torque please follow the antenna installation leaflet
(available in package).
End of procedure for sectoral 26/28/32 GHz.
Continued on next page
(1) The values must be taken from RF planning team.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
63
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
19
Install the OSDR onto the antenna as described to steps 5, 6 and 7.
20
To correct the elevation angle for matching with the RF planning data, perform the
following actions:
A: Place the inclinometer, as shown below.
B:
Use the U-wrench tool to perform elevation adjustment, as shown below.
Perform adjustment till the inclinometer reaches the desirable RF
planning value.
C: All elevation nuts and bolts should be tightened.
• Do not over tighten.
• For maximum tightening torque please follow the antenna installation
leaflet (available in package).
Continued on next page
4. Installation Procedures
64
Sectoral and Parabolic Antenna, Continued
Procedure, continued
Step
Action
21
Use the U-wrench tool to perform azimuth adjustment(1), as shown below.
• Do not over tighten.
• For maximum tightening torque please follow the antenna installation leaflet
(available in package).
End of procedure for sectoral 10.5 GHz.
End of procedure.
(1) The values must be taken from RF planning team.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
65
Panel Antenna
Introduction
This topic describes the following procedures:
Description
See Page
Mounting kit installation procedure
66
Panel antenna installation procedure
71
Tools and
materials
#
Description
Tools
• Adjustable torque U-wrench.
• Adjustable torque wrench with bit (hexagon male and cross).
• Allen key.
Materials
• OSDR-ANT-MNT.
• OSDR-PL-ANT-KIT.
• GRS-PST.
• OSDR.
• Panel antenna.
Mounting kit
overview
Continued on next page
4. Installation Procedures
66
Panel Antenna, Continued
Mounting kit
installation
procedure
To install the mounting kit, proceed as follows:
Step
Action
1
Perform the following actions:
A: Unscrew the azimuth adjuster screw.
B: Release the u-bolts.
2
Place the arm bracket to the pole and install the two U-bolts, as
shown below.
Use the U-wrench to tighten (washer, lock washer and nut).
Do not over tighten. Adjust the tool for max tightening
torque 15 Nm.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
67
Panel Antenna, Continued
Mounting kit installation procedure, continued
Step
Action
3
Perform the following actions:
A: Unscrew the four screws.
B: Place the radio mounting adapter onto the OSDR, as shown below.
C: Install and screw the four screws.
Do not over tighten. Adjust the tool for max tightening torque 4.2 Nm.
Continued on next page
4. Installation Procedures
68
Panel Antenna, Continued
Mounting kit
installation
procedure,
continued
Step
Action
4
Insert arm into the arm bracket, as shown below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
69
Panel Antenna, Continued
Mounting kit installation procedure, continued
Step
Action
5
Perform the following actions:
A: Install the azimuth adjuster (taking into account the caution), as shown
below.
B: Install the azimuth adjuster bolt, as shown below (washer, lock washer and
bolt).
Continued on next page
4. Installation Procedures
70
Panel Antenna, Continued
Mounting kit installation procedure, continued
Step
Action
6
Use the adjustable wrench to fully tighten the adjuster bolt.
Do not over tighten. Adjust the tool for max tightening torque 20 Nm.
The installation should look as follows.
End of procedure.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
71
Panel Antenna, Continued
Panel antenna
installation
procedure
To install the panel antenna to OSDR, proceed as follows:
Step
Action
1
Install the antenna hooks (x 4), as shown below.
Continued on next page
4. Installation Procedures
72
Panel Antenna, Continued
Panel antenna installation procedure, continued
Step
Action
2
Radio unit and antenna should be adjusted for common polarization. If the LINK
polarization is HORIZONTAL then the feeders should be remained, as shown
below:
If the LINK polarization is VERTICAL, use the allen key to loosen the four screws
at the waveguide port of the radio (do not remove the screws) and then TURN the
polarizer, as shown below:
The terminal station polarization at 10.5 GHz (radio-panel antenna) is specific and
applicable to this case only.
Do not over tighten the screws. Apply maximum tightening torque 0.6 Nm.
The misalignment of slots between the movable part and the stationary part of the radio
waveguide port is intentional and does not indicate a problem.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
73
Panel Antenna, Continued
Panel antenna
installation
procedure,
continued
Step
Action
3
Perform the following actions:
A: Lubricate the O-ring with silicone grease.
B: Remove antenna protection plastic sticker from the
feeder.
4
Unlock the four radio unit clamps, as shown below.
Continued on next page
4. Installation Procedures
74
Panel Antenna, Continued
Panel antenna
installation
procedure,
continued
Step
Action
5
Mount the panel antenna onto the OSDR, as shown below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
75
Panel Antenna, Continued
Panel antenna
installation
procedure,
continued
Step
Action
6
Lock and secure all four clamps according to the pattern below.
Details of Clamps closing
End of procedure
4. Installation Procedures
76
4.2. Radio Unit Grounding Cable
Introduction
Apply this procedure for installing the grounding cable to OSDR grounding
terminal.
Prerequisites
How to terminate a grounding cable please refer to Appendix D: Cables
Termination.
Tools and
materials
#
Description
Tools
Adjustable torque U-wrench.
Materials
GND-KIT16-OD
Procedure
To install the grounding cable to OSDR, proceed as follows:
Step
Action
1
Use the tool to remove the M5 nut and one spring washer.
Then install the cable, as shown below.
Use the adjustable U-wrench to tighten the M5 nut.
Do not over tighten. Adjust the tool for max tightening
torque 4.2 Nm.
After completion of OSDR installation do not forget to
install the other end of the grounding cable to grounding
bar.
End of procedure.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
77
4.3. Radio Unit Ethernet (S-FTP) Cable
Introduction
Apply this procedure for installing the Ethernet (S-FTP) cable with M20 gland
to OSDR receptacle (GbE2 or FE).
Prerequisites
How to terminate an Ethernet (S-FTP) cable please refer to Appendix D:
Cables Termination.
Tools and
materials
#
Description
Tools
Adjustable torque U-wrench.
Materials
• M20-GLAND.
• Terminated Ethernet (S-FTP) cable to RJ-45 jack.
Continued on next page
4. Installation Procedures
78
Radio Unit Ethernet (S-FTP) Cable, Continued
Procedure
To install the Ethernet cable with M20 gland to OSDR receptacle (GbE2 or
FE), proceed as follows:
Step
Action
1
Remove the protective cap (plastic for GbE2 or metallic for FE).
2
Disassemble the M20-GLAND parts, as shown below.
3
Pass the cable through the parts of gland, as shown below.
The seal shown below is split-type for easy installation and
removal.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
79
Radio Unit Ethernet (S-FTP) Cable, Continued
Procedure, continued
Step
Action
4
Plug the RJ-45 jack into the GbE2 port of the OSDR.
Listen for a “click” when inserting. This verifies that the jack has been
inserted properly.
5
Perform the following actions:
A: Screw the body into the OSDR
thread.
Do not over tighten. Adjust the
tool for max tightening torque
7 Nm.
B: Insert claw into the body
(taking into account the
caution).
Align the designated points.
Misaligning of parts will cause
damage.
Continued on next page
4. Installation Procedures
80
Radio Unit Ethernet (S-FTP) Cable, Continued
Procedure,
continued
Step
Action
6
Perform the following actions:
A: Insert the seal into “pressure fingers” of claw.
B: Insert the O-ring.
C: Screw the sealing nut. Use the adjustable torque U-
wrench to fully tighten.
The ring protects from overtightening.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
81
Radio Unit Ethernet (S-FTP) Cable, Continued
Procedure,
continued
Step
Action
7
Install the cable holder, as described to Radio Unit Cable Holder
on page 88.
End of procedure.
Take care when you unplug the RJ-45 jack. The latter is locked
into the mating receptacle.
After removing the gland parts of the cable use the flat-headed
screwdriver to extract the RJ-45 jack by pressing the clip upwards, as
shown below:
4. Installation Procedures
82
4.4. Power Injector
For power injectors installation refer to Appendix C: Power Injector
Installation on page 96.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
83
4.5. Radio Unit Optical Cable (Optional)
Introduction
Apply this procedure for installing the Fiber Optic cable with M25 gland to
OSDR receptacle (GbE1).
Tools and
materials
#
Description
Tools
Adjustable torque U-wrench.
Materials
• M25-GLAND.
• Fiber Optic cable.
• SFP module.
Procedure
To install the Fiber Optic cable with M25 gland to OSDR receptacle (GbE1),
proceed as follows:
Step
Action
1
Remove the metallic protective cap.
2
Disassemble the M25-GLAND parts, as shown below.
Continued on next page
4. Installation Procedures
84
Radio Unit Optical Cable (Optional), Continued
Procedure,
continued
Step
Action
3
Pass the cable through the parts of gland, as shown below.
The seal shown below is split-type for easy installation and
removal.
4
Perform the following actions:
A:
Install the fiber optic cable into the SFP module.
B:
Plug the SFP module into the OSDR SFP cage.
C:
Install the body extension.
Do not over tighten. Adjust the tool for max tightening
torque 10 Nm.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
85
Radio Unit Optical Cable (Optional), Continued
Procedure, continued
Step
Action
5
Perform the following actions:
A: Screw the body into the body
extension thread.
Do not over tighten. Adjust the
tool for max tightening torque
10 Nm.
B: Insert claw into the body
(taking into account the
caution).
Align the designated points.
Misaligning of parts will cause
damage.
Continued on next page
4. Installation Procedures
86
Radio Unit Optical Cable (Optional), Continued
Procedure, continued
Step
Action
6
Perform the following actions:
A: Insert the seal into “pressure fingers” of claw.
B: Insert the O-ring.
C: Screw the sealing nut. Use the adjustable torque U-wrench to fully tighten.
The ring protects from overtightening.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
87
Radio Unit Optical Cable (Optional), Continued
Procedure,
continued
Step
Action
7
Install the cable holder, as described to Radio Unit Cable Holder
on page 88.
End of procedure.
Take care when you unplug the fiber optic connector.
The latter is locked into the SFP and must be extracted first (with the
tip of a flat-headed screwdriver) after removing the gland parts from
the lower part of OSDR.
4. Installation Procedures
88
4.6. Radio Unit Cable Holder
Introduction
Apply this procedure for installing the cable holder to OSDR.
Tools and
materials
#
Description
Tools
Adjustable torque wrench with hexagon male bit
Materials
OSDR-HOLD-2 or OSDR-HOLD-5
Procedure
To install the cable holder, proceed as follows:
Step
Action
1
Use the tool to remove the three screws with lock washers, as
shown below.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
89
Radio Unit Cable Holder, Continued
Procedure,
continued
Step
Action
2
Perform the following:
A: Attach the holder to radio.
B: Use the tool to install the three lock washers and screws,
as shown below.
Do not over tighten. Adjust the tool for max tightening
torque 2 Nm.
3
Install cables and glands.
How to install refer to the following:
• Radio Unit Ethernet (S-FTP) Cable on page 77.
• Radio Unit Optical Cable (Optional) on page 83.
Continued on next page
4. Installation Procedures
90
Radio Unit Cable Holder, Continued
Procedure,
continued
Step
Action
4
Use the tie wraps to tighten the cable, as shown below.
End of procedure.
Do not forget to install the OSDR grounding cable.
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
91
Appendix A: Adaptation Kit Installation
Pole Installation
Introduction
Apply this procedure for installing the adaptation kit onto the pole.
Tools and
materials
#
Description
Tools
• Adjustable torque U-wrench.
• Adjustable torque wrench with hexagon female bit.
Materials
INST-ADAPT.
Continued on next page
Appendix A: Adaptation Kit Installation
92
Pole Installation, Continued
Procedure
To install adaptation kit onto the pole, proceed as follows:
Step
Action
1
Choose the proper hose clamps based on the pole diameter.
2
Pass through the clamps to bracket, as shown below:
3
Choose the correct position onto the pole to install the
adaptation bracket.
4
Use the tool to tighten.
Do not over tighten. Adjust the tool for tightening
torque, as follows:
• min 5.5 Nm.
• max 7.0 Nm.
Continued on next page
Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
93
Pole Installation, Continued
Procedure,
continued
Step
Action
5
Install the arm bracket onto the adaptation bracket, as shown
below.
Do not over tighten. Adjust the tool for max tightening
torque 15 Nm.
End of procedure
Appendix B: Mounting Kit Wall Installation
94
Appendix B: Mounting Kit Wall Installation
Wall Installation
Introduction
Apply this procedure for installing the mounting kit onto the wall.
Tools and
materials
#
Description
Tools
Adjustable torque U-wrench.
Materials
OSDR-ANT-MNT.
Procedure
To install radio unit to sectoral/parabolic antenna, proceed as follows:
Step
Action
1
Use a drilling machine (fitted with an 8 mm drill bit) and the
following drill template to drill the holes in the wall surface, as
shown below.
Continued on next page