Electrical and Mechanical Specifications

Physical SPX-1300 Aluminum Enclosure 3.5" x 2.75" x .75" Temp Storage(-55˚C to + 150˚C)" Operating(-40˚C to +80˚C) Humidity 95% (non-condensing) Power Input Unreg Input 8 to 16 VDC* @ 200mA Max Output +5VDC @100mA Data I/O" Voltage Ratings Interf

External connections and DIP Switch Settings

8-485(+)" 7-485(-)" 6-+5 VDC Out" 5-Prog Res 2" 4-Prog Res 1" 3-LED Input" 2-D1/Data/F2F Out-" 1-D0/CLK Out 2-8 to 16 VDC In" 1-Ground Diagnostic LED 12-RLY4 N.O." 11-RLY4 Com" 10-RLY4 N.C." 9-RLY3 N.O." 8-RLY3 Com" 7-RLY3 N.C." 6-RS232 Out" 5-RS232 In" 4-Groun

Temperature/Voltage de-rating curve

Electrical and Environmental Specifications The SPX-1300 units should be operated with a filtered 12 Volt nominal DC supply. " However, any voltage between 8 and 16 volts can be utilized by following the te

When the Suprex units are operating correctly and have a valid communication channel between"

the Remote and Central units the Diagnostic indicators on each unit will flash green rapidly " (2-3 flashed per second)." " If the units are not communicating, viewing the diagnostic indicator LED’s may help t