Electrical and Mechanical Specifications
Physical
SPX-1300 Aluminum Enclosure 3.5" x 2.75" x .75"
Temp
Storage(-55˚C to + 150˚C)"
Operating(-40˚C to +80˚C)
Humidity
95% (non-condensing)
Power
Input
Unreg Input 8 to 16 VDC* @ 200mA Max
Output
+5VDC @100mA
Data I/O"
Voltage Ratings
Interf
External connections and DIP Switch Settings
8-485(+)"
7-485(-)"
6-+5 VDC Out"
5-Prog Res 2"
4-Prog Res 1"
3-LED Input"
2-D1/Data/F2F Out-"
1-D0/CLK Out
2-8 to 16 VDC In"
1-Ground
Diagnostic LED
12-RLY4 N.O."
11-RLY4 Com"
10-RLY4 N.C."
9-RLY3 N.O."
8-RLY3 Com"
7-RLY3 N.C."
6-RS232 Out"
5-RS232 In"
4-Groun
Temperature/Voltage de-rating curve
Electrical and Environmental Specifications
The SPX-1300 units should be operated with a filtered 12 Volt nominal DC supply. "
However, any voltage between 8 and 16 volts can be utilized by following the te
When the Suprex units are operating correctly and have a valid communication channel between"
the Remote and Central units the Diagnostic indicators on each unit will flash green rapidly "
(2-3 flashed per second)."
"
If the units are not communicating, viewing the diagnostic indicator LED’s may help t