VR1000 3w Cool or Warm White User Manual

Specifications Input Voltage: 240v AC 50-60Hz Power Consumption: 75w Dimensions: 1000 x 80 x 75mm Weight: 5.1kg LED’s: 24 x 3w Cool or Warm White LED’s Beam Angle: 40deg DMX Connections: 3 pin male / female flying leads with IP65 rated connectors Mains Link: 4 pin male / female flying leads with IP65 rated connectors Infra – Red Remote Control Sensor Features Infra Red Remote Control (Using optional VRIR remote Transmitter) Stand Alone / Master Slave DMX 512 Controllable (2 x Channel) 410Hz LED Driver Chips for Flicker Free Operation when using Video Equipment IP65 Rated for Outdoor Use Power and DMX Linkable Low Power Consumption Thermal Protection Aluminium Housing with tempered Glass Front Rubberised easy wrap cable Optional Data & Power link leads are available in various lengths Introduction Thank you for choosing the VR1000 3w Cool or Warm White Baton. Prior to use, please read all the instructions carefully paying particular attention to the installation of this product. By following the suggestions found in this user manual you can look forward to long and reliable service of your new product. Unpacking, Inspection and Installation Please check that the following items are included in your packaging. If anything is missing please contact your dealer. VR1000 Unit • Power cord with 13A mains plug Carefully remove all packaging materials from the box, ensuring that all foam padding is discarded responsibly. This unit can be mounted and operated at any angle; however we would recommend using a suitable safety chain if the unit is to be installed above head height. As little or no heat is generated by the unit it can safely be installed behind marquee linings and drapes.

Connect your VR Outdoor LED light to a suitable mains supply with the power

lead (Included) Note: The whole range of VR Outdoor lights can be connected together in any sequence. Up to 8 Units can be linked together using the IP64 rated mains link leads. Extension Data and Mains Links in various lengths are available as an optional extra. Operation The VR Range of outdoor lighting requires a VRIR Infra-Red Remote control transmitter to set up the units. They can then be controlled either using the VRIR, by a suitable DMX 512 controller. Infra-Red remote Control Operation Using the VR/IR Infra-R ed remote control transmitter. Please note that the remote supplied with the unit is designed for use with the Colour Changing Units, hence the difference in key selection. VRIR Instructions Point the VRIR controller at the IR lens on the front of the VR1000 Baton. 1. Press BLCK OUT to switch the units on or off. 2. Press the “A button to select the Pulse Mode. Note: Pressing A again will toggle between Pulse and Off. Note: Use in conjunction with the F button followed by the + & - buttons to adjust the speed of the Pulse. 3. The Prog Button selects Strobe Mode. Note: Use in conjunction with the F button followed by the + & - buttons to adjust the speed of the Strobe. 4. Pressing SP puts the unit into DMX mode. 5. Use the D button in conjunction with the numbered buttons to set the DMX address. Note: Refer to example of how to set the DMX address. 6. Pressing the SL button puts the unit into Slave mode. 7. The SA button is used to control the intensity of the white LED’s. Note: Use in conjunction with the + & - Buttons. 8. The D button used in conjunction with the numbered 0 to 9 buttons sets the units DMX address, (see example below). Setting the DMX Address using the VRIR (Example to set the DMX address to 001) 1. Press the D button; note that all the LED’s will Flash then one set of LED’s will remain lite indicating that the unit is ready to accept the first digit of the DMX address to be set. 2. Press the 0 button; note that the sequence of LED’s will change, indicating that the first number in the 001 address has been entered.

3. Press the 0 button again, note that the sequence of LED’s will change;

indicating that the second number in the 001 address has been entered. 4. Press the 1 button, note that all the LED’s on the unit light, will flash and then go out, indicating that the final number in the 001 address has been set and the unit is ready to accept a DMX signal from the controller. Note: To operate the unit in manual IR mode, after a DMX address has been set, simply point the remote at the unit and press the buttons required. The unit will automatically switch back to manual mode. To go back to DMX mode, simply press: SP, this will switch the unit back to DMX mode and the last address set. Master / Slave Mode Multiple units together using the data and mains flying leads or extension leads. The first unit in the chain will be the master unit; all the other units are slaves so should be set to slave as detailed in the VRIR operation above. Connect all the units to a suitable mains supply then whatever the Master unit is set to, the Slave units will copy. DMX Mode The unit can be set to DMX mode (as above) which will enable accurate control over the LED dimming using a compatible DMX 512 Controller. DMX Protocol Table Channel DMX Value Function 1 000 – 255 Dimming 0 – 100% 2 011 – 255 Strobe 0 – 100%