Keysight Technologies U1281A A CAUTION notice denotes a

hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if n

Keysight U1281A/U1282A Quick Start Guide

3 Standard Shipped Items Verify that you have received the following items with the shipment of your U1281A/U1282A multimeters: ✔ Test leads (red and black) ✔ IR-to-USB cable ✔ Four 1.5 V AA batteries ✔ Printed copy of the U1281A/U1282A Quick Start Guide (this document) ✔ Printed copy of the Certificate of Calibration If any item is missing or damaged, keep the shipping materials and contact the nearest Ke
Keysight U1281A/U1282A Quick Start Guide Install or Change the Batteries The multimeter is powered by four 1.5 V AA batteries (included in the shipment). Before installing or changing the batteries, pull from a corner and stretch the orange rubber holster to remove it. Turn On the Multimeter Turn the rotary switch from the position to any other position to begin making measurements. A mA COM V V A V mV mV U1282A True RMS Multim eter mA Peak Vsense Dual
Keysight U1281A/U1282A Quick Start Guide 5 The Multimeter at a Glance A mA COM V V A V mV mV U1282A True RMS Multimeter mA Vsense Peak Vsense Dual Auto FUSED 440mA CAT III 1000V 600V CAT IV MAX 10A MAX FUSED OUT OUT MHz RMT Vsense red LED indicator Display screen Keypad Rotary switch Input terminals IR communication port Test lead/probe holders Battery access (under the orange rubber holster) Tilt stand Fuse access (under the orange rubber holster)
Keysight U1281A/U1282A Quick Start Guide Using the Rotary Switch Legend Measurement function Model U1281A U1282A AC V/AC V with Low Pass Filter (LPF)[a] ✔ ✔ AC mV/AC mV with LPF[a] ✔ ✔ DC/AC/AC+DC V ✔ ✔ DC/AC/AC+DC mV ✔ ✔ Resistance/Continuity ✔ ✔ Diode/Frequency counter[a] ✔ ✔ Capacitance/Temperature ✔ ✔ DC μA/mA/AC μA/mA/AC+DC μA/mA ✔ ✔ DC A/AC A/AC+DC A ✔ ✔ Square wave mode[a] — ✔ [a] For U1282A only. V mV V
Keysight U1281A/U1282A Quick Start Guide 7 Using the Keypad Legend Key response when pressed for: Less than 1 second More than 1 second – Starts the Max/Min/Avg recording – Switches between the Max/Min/Avg recording modes – Stops the Max/Min/Avg recording – Starts and stops the Peak recording Sets the Null/Relative mode Enables and disables the non-contact voltage detection – Vsense[a] Sets a manual range Enables autoranging Enables the frequency
Keysight U1281A/U1282A Quick Start Guide Using the Input Terminals WARNING To avoid damaging this device, do not exceed the input limit. Rotary position Input terminals Overload protection 1000 Vrms 1000 Vrms for short circuit <0.3 A 440 mA/1000 V, fast-acting fuse 11 A/1000 V, fast-acting fuse This input terminal is for use with the Remote Switch Probe (purchased separately). The button on the probe emulates the button on the multimeter by default. V V
Keysight U1281A/U1282A Quick Start Guide 9 Safety Alerts and Warnings Hazardous voltage indication The multimeter will display the hazardous voltage ( ) symbol as an early precaution when the measured voltage is: This symbol will also be displayed when the input signal exceeds the limitation of measuring circuit as frequency dependence. Hazardous current indication The multimeter will display the hazardous current ( ) symbol as an early precaution when the