Keysight Technologies U1281A Quick Start Manual
| Brand: | Keysight Technologies |
| Category: | Multimeter |
| Model: | U1281A (Quick Start Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 29 |
Text of Keysight Technologies U1281A Quick Start Manual
Keysight Technologies U1281A A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION
notice until the indicated
conditions are fully understood
and met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if n
Keysight U1281A/U1282A Quick Start Guide
3
Standard Shipped Items
Verify that you have received the following items
with the shipment of your U1281A/U1282A
multimeters:
✔
Test leads (red and black)
✔
IR-to-USB cable
✔
Four 1.5 V AA batteries
✔
Printed copy of the U1281A/U1282A
Quick Start Guide (this document)
✔
Printed copy of the Certificate of Calibration
If any item is missing or damaged, keep the
shipping materials and contact the nearest Ke
Keysight U1281A/U1282A Quick Start Guide Install or Change the Batteries
The multimeter is powered by four 1.5 V AA
batteries (included in the shipment).
Before installing or changing the batteries, pull from
a corner and stretch the orange rubber holster to
remove it.
Turn On the Multimeter
Turn the rotary switch from the
position to any
other position to begin making measurements.
A
mA
COM
V
V
A
V
mV
mV
U1282A
True RMS Multim eter
mA
Peak
Vsense
Dual
Keysight U1281A/U1282A Quick Start Guide 5
The Multimeter at a Glance
A
mA
COM
V
V
A
V
mV
mV
U1282A
True RMS Multimeter
mA
Vsense
Peak
Vsense
Dual
Auto
FUSED
440mA
CAT III 1000V
600V
CAT IV
MAX
10A MAX
FUSED
OUT
OUT
MHz
RMT
Vsense red LED indicator
Display screen
Keypad
Rotary switch
Input terminals
IR communication port
Test lead/probe holders
Battery access
(under the orange rubber holster)
Tilt stand
Fuse access
(under the orange rubber holster)
Keysight U1281A/U1282A Quick Start Guide Using the Rotary Switch
Legend
Measurement function
Model
U1281A
U1282A
AC V/AC V with Low Pass Filter (LPF)[a]
✔
✔
AC mV/AC mV with LPF[a]
✔
✔
DC/AC/AC+DC V
✔
✔
DC/AC/AC+DC mV
✔
✔
Resistance/Continuity
✔
✔
Diode/Frequency counter[a]
✔
✔
Capacitance/Temperature
✔
✔
DC μA/mA/AC μA/mA/AC+DC μA/mA
✔
✔
DC A/AC A/AC+DC A
✔
✔
Square wave mode[a]
—
✔
[a]
For U1282A only.
V
mV
V
Keysight U1281A/U1282A Quick Start Guide 7
Using the Keypad
Legend
Key response when pressed for:
Less than 1 second
More than 1 second
– Starts the Max/Min/Avg
recording
– Switches between the
Max/Min/Avg recording
modes
– Stops the Max/Min/Avg
recording
– Starts and stops the
Peak recording
Sets the Null/Relative mode
Enables and disables the
non-contact voltage
detection – Vsense[a]
Sets a manual range
Enables autoranging
Enables the frequency
Keysight U1281A/U1282A Quick Start Guide Using the Input Terminals
WARNING
To avoid damaging this device, do not exceed the
input limit.
Rotary
position
Input terminals
Overload protection
1000 Vrms
1000 Vrms for short
circuit <0.3 A
440 mA/1000 V,
fast-acting fuse
11 A/1000 V,
fast-acting fuse
This input terminal is for use with the Remote Switch Probe (purchased
separately). The button on the probe emulates the
button on the
multimeter by default.
V
V
Keysight U1281A/U1282A Quick Start Guide 9
Safety Alerts and Warnings
Hazardous voltage indication
The multimeter will display the hazardous voltage
( ) symbol as an early precaution when the
measured voltage is:
This symbol will also be displayed when the input
signal exceeds the limitation of measuring circuit as
frequency dependence.
Hazardous current indication
The multimeter will display the hazardous current
( ) symbol as an early precaution when the