JA40-001 Intercom Tie Line Isolation Transformer

Data Sheet Description Typical Application The JA40 Intercom Tie Line Transformer allows up to 4 tie lines to be transformer coupled with a minimum crosstalk and noise interference. ICS TIE LINE ICS TIE LINE ICS TIE LINE ICS TIE LINE AUDIO CONTROLLER AUDIO CONTROLLER AUDIO CONTROLLER AUDIO CONTROLLER ISOLATION TRANSFORMER JA40-001 JA9X JA9X JA9X JA9X TO ONLINE INFO TO ONLINE INFO TO ONLINE INFO TO ONLINE INFO 1959 Kirschner Rd, Kelowna, BC V1Y 4N7 Tel: (778) 478-2232 Toll-Free: (855) 478-2232 www.jupiteravionics.com TM JA40-001 Data Sheet Rev A.pdf

CONFIDENTIAL & PROPRIETARY

JUPITER AVIONICS TEMPLATE SOLIDWORKS LANDSCAPE SIZEA.DRWDOT JA40 3D MODEL JA40-001 3D Model Rev A.SLDDRW DOC. NO. 1/1 SHEET JA40-001 PART NO. NCAGE CODE L00N3 A N/A MATERIAL: FINISH: TO JUPITER AVIONICS CORP. APPROVED CHECKED TAT PREPARED N/A UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES ANGLES ARE IN DEGREES TOLERANCES: 1 DEC PLACE: 0.1 2 DEC PLACE: 0.01 3 DEC PLACE: 0.005 ANGLES: 0.5 DEG 88.9mm 3.50in 114.3mm 4.50in 58.4mm 2.30in 31.8mm 1.25in 2.40in 61mm JA40-001 Specifications Installation Environment and Performance Weight: 0.44 lb. [0.20 Kg] Max. Operating Temperature -40 C to +70 C Survival Temperature -55 C to +85 C Altitude 50,000 ft. max Humidity 95%, 48 hrs Shock 20g (any axis) TSO Compliance CAN TSO-C139 (Pending) Installation Kit INST-JA40 2k ohm 2k ohm 2k ohm 2k ohm © 2012 Jupiter Avionics Corporation 1959 Kirschner Rd, Kelowna, BC V1Y 4N7 Tel: (778) 478-2232 Toll-Free: (855) 478-2232 www.jupiteravionics.com TM Printed in Canada

ICS Tie Line Isolation Transformer

Installation Manual Rev. B Jupiter Avionics Corporation 1959 Kirschner Road Kelowna BC Canada V1Y 4N7 Tel: +1 778 478 2232 Toll-Free: 1 855 478 2232 www.jupiteravionics.com

JA40-001 ICS Tie Line Isolation Transformer

Installation and Operating Manual Rev B Page ii Copyright 2013 Jupiter Avionics Corp. All rights reserved Jupiter Avionics Corporation (JAC) permits a single copy of this manual to be printed or downloaded for the express use of an installing agency. Any such electronic or printed copy of this manual must contain the complete text of this copyright notice. Any unauthorized commercial distribution of this manual is strictly prohibited. Except as described above, no part of this manual may be reproduced, copied, transmitted, disseminated, downloaded, or stored in any storage medium for any purpose without the express prior written consent of JAC. RECORD OF REVISIONS Revision Rev Date Description ECR A Nov 2013 Initial release, Serial number 1001 and higher. 1023 B Feb 2014 Certification statement changed Prepared: MPB Checked: Approved: IMPORTANT: Information in this document is subject to change without notice. To confirm the current revision status of this manual, visit the JAC website: www.jupiteravionics.com

JA40-001 ICS Tie Line Isolation Transformer

Installation and Operating Manual Rev B Page iii Table of Contents SECTION 1 - DESCRIPTION ........................................................................................................................................... 1 1.1 System Overview .............................................................................................................................................. 1 1.2 Features Overview ............................................................................................................................................ 1 1.3 Inputs and Outputs ........................................................................................................................................... 1 1.3.1 Bi-directional Ports .................................................................................................................................... 1 1.4 Specifications .................................................................................................................................................... 1 1.4.1 Electrical Specifications ............................................................................................................................ 1 1.4.2 Mechanical Specifications ........................................................................................................................ 2 1.4.� Flammability of Materials .......................................................................................................................... 2 SECTION 2 – INSTALLATION ........................................................................................................................................ 1 2.1 Introduction ....................................................................................................................................................... 1 2.2 Continued Airworthiness ................................................................................................................................... 1 2.3 Unpacking and Inspecting Equipment .............................................................................................................. 1 2.3.1 Warranty ....................................................................................................................................................... 1 2.4 Installation Procedures ..................................................................................................................................... 1 2.4.1 Cabling and Wiring ....................................................................................................................................... 1 2.4.2 Mechanical Installation ................................................................................................................................. 2 2.4.3 Post Installation Checks ............................................................................................................................... 2 2.5 System Operation ............................................................................................................................................. 2 2.6 Installation Kit ................................................................................................................................................... 2 2.6.1 Recommended Crimp tools ...................................................................................................................... 2 2.7 Installation Drawings ......................................................................................................................................... 2 Appendix A - Installation Drawings ........................................................................................................................... A1 A1 Introduction ..................................................................................................................................................... A1 A2 Installation Drawings ....................................................................................................................................... A1 Appendix B - ������������ Documents ....................................................................................................................��.. B1 B1 Airworthiness �������������� ................................................................................................................................... B2 B2 Instructions for Continued Airworthiness ........................................................................................................ B2

JA40-001 ICS Tie Line Isolation Transformer

SECTION 1 - DESCRIPTION 1.1 System Overview The JA40 Intercom Tie Line Isolation Transformer allows four bi-directional intercom tie lines to be coupled and provides galvanic isolation. This prevents ground loops and common impedance problems in multi-box intercom installations. 1.2 Features Overview The JA40 features a fully balanced interconnect with shielded transformers and an aluminum enclosure. 1.3 Inputs and Outputs Refer to the JA40-001 connector map for the mating connector designators and pin assignments for the input and output signals. 1.3.1 Bi-directional Ports ICS Tie-line The JA40 connector has eight contacts to provide four ICS TIE LINE HI / LO bidirectional audio signals. 1.4 Specifications 1.4.1 Electrical Specifications The JA40 does not require aircraft electrical power. 1.4.1.1 Audio Performance Rated Input Level Audio rated input level 1.20 Vrms ±10 % Rated Output Power Audio rated output power 1.20 Vrms ±20 % Audio Frequency Response Audio frequency response ≤ 3 dB from 300 to 6000 Hz Distortion Characteristics Audio output distortion at rated power ≤ 10 % Audio output distortion at 10% of rated power ≤ 3 % Connected Load ICS TIE load (4 ea.) 2000 Ω ±10 %

JA40-001 ICS Tie Line Isolation Transformer

Installation Manual Rev B Page 2 Input to output Crosstalk and Bleed-through Level N/A Input to Input Crosstalk Level N/A Audio Noise Level without Signal Noise level below the rated output ≥ 60 dB 1.4.1.2 Audio Performance, Other ICS TIE LINE HI/LO circuitry type Transformer coupled 1.4.2 Mechanical Specifications Height 1.27 in [32.3 mm] maximum Depth 2.61 in [66.3 mm] maximum Width 4.52 in [114.8 mm] maximum Weight 0.37 lbs [0.167 kg] maximum Material brushed aluminum with conversion coating Connector J1 One 9-pin D-Sub male V5 locking Mounting 4 x 10-32 fasteners Bonding ≤ 2.5 mΩ Installation kit part number INST-JA40 1.4.� Flammability of Materials The JA40-001 complies with the requirements of RTCA/DO-160G Sec 26.3.3 "Flammability", through equivalent flammability testing of materials and the Small Parts Exemption.

JA40-001 ICS Tie Line Isolation Transformer

CAUTION: The power input circuitry of the unit may be damaged if the installation does not conform to the wiring instructions in this manual. SECTION 2 – INSTALLATION 2.1 Introduction This section contains unpacking and inspection procedures, installation information, and post-installation checks. 2.2 Continued Airworthiness Maintenance of the JA40-001 is on condition only. Scheduled inspection and/or periodic maintenance of this unit is not required. 2.3 Unpacking and Inspecting Equipment Unpack the equipment carefully. Check for shipping damage and report any problems to the relevant carrier. Confirm that the Authorized Release Certificate or Certificate of Conformance is included. Complete the on-line warranty card from the Jupiter Avionics Corporation (JAC) website – www.jupiteravionics.com/warranty 2.3.1 Warranty All products manufactured by JAC are warranted to be free of defects in workmanship or performance for 2 years from the date of installation by an approved JAC dealer or agency. This warranty covers the cost of all materials and labour to repair or replace the unit, but does not include the cost of transporting the defective unit to and from JAC or its designated warranty repair centre, or of removing and replacing the defective unit in the aircraft. This warranty does not cover failures due to abuse, misuse, accident, or unauthorized alteration or repairs. THIS WARRANTY IS VOID IF THE PRODUCT IS NOT INSTALLED BY AN AUTHORIZED JAC DEALER. If the on- line warranty card is not completed, the product will be warranted from the date of manufacture. Contact JAC for return authorization, and for any questions regarding this warranty and how it applies to your unit(s). JAC is the final arbiter concerning warranty issues. 2.4 Installation Procedures 2.4.1 Cabling and Wiring All wire shall be selected in accordance with the original aircraft manufacturer’s maintenance instructions, or AC43.13- 1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11. For shielded wire applications, use Tefzel MIL-C-27500 shielded wire with tag ring or equivalent (for shield terminations) to make the most compact and easily terminated interconnect. Follow the Connector Map in Appendix A of this manual. Allow 3” from the end of the shielded wiring to the shield termination to allow the connector hood to be easily installed. Refer to the Interconnect drawing in Appendix A of this manual for shield termination details. Note that this unit has a ‘clamshell’ hood that is installed after the wiring is complete. Maintain wire segregation and route wiring in accordance with the original aircraft manufacturer’s maintenance instructions. Unless otherwise noted, all wiring shall be a minimum of 24 AWG, except ground lines, which shall be a minimum of 20 AWG. Refer to the Interconnect drawing for additional specifications. Check that the ground connection is clean and well secured, and that it shares no path with any electrically noisy aircraft accessories such as blowers, turn-and- bank instruments, or similar loads.

JA95-001 Aural Message Generator

Installation and Operating Manual Rev B Page A2 2.4.2 Mechanical Installation The JA40-001 can be mounted in any attitude and location with adequate space and sufficient clearance for the connector and wiring harness. It requires no direct cooling. 2.4.3 Post Installation Checks 2.4.3.1 Voltage/Resistance checks. Do not attach this unit until the following conditions are met: a) Check P1 pin 5 for continuity to ground (less than 0.5 Ω). b) Check all pins for shorts to ground or adjacent pins. 2.4.3.2 Power on Checks. Power up the aircraft’s systems and confirm normal operation of all functions of the JA40. When all performance checks are satisfied, complete the necessary regulatory documentation before releasing the aircraft for service. Refer to Appendix B. 2.5 System Operation The JA40-001 combines up to four bi-directional ICS TIE Line audio signals from four intercoms. 2.6 Installation Kit The kit required to install this unit is not included with the unit. The installation kit (Part # INST-JA40) consists of the following: Quantity Description JAC Part # 1 9 Socket, D-Submin - Crimp Socket Connector Assy CON-3420-0009 1 0.375" Inside Diameter, Hardware - Tag Ring CON-5500-0375 1 JA40-001 Assembly Notes, Installation Kit DOC-INST-JA40 1 3/4" Inside Diameter, Heat Shrink Tube WIR-HTSK-0750 2.6.1 Recommended Crimp tools Connector Type Hand crimp tool Positioner Insertion/extraction tool Positronic 9507 9502-3 M81969/1-04 Positronic AFM8 (Daniels) M22520/2.08 KB-1 2.7 Installation Drawings The drawings and documents required for Installation can be found in Appendix A of this manual.

JA40-001 ICS Tie Line Isolation Transformer

Installation Manual Appendix A - Installation Drawings A1 Introduction The drawings necessary for installation and troubleshooting of the JA40-001 ICS Tie Line Isolation Transformer are in this Appendix, as listed below. A2 Installation Drawings DOCUMENT Rev JA40-001 Connector Map A JA40-001 Interconnect A JA40-001 Mechanical Installation A

JUPITER AVIONICS TEMPLATE AUTOCAD PORTRAIT SIZEA REV B.DWT

TITLE APPROVED PREPARED CHECKED L00N3 NCAGE CODE PART NO. SHEET DOC NO. CONFIDENTIAL & PROPRIETARY TO JUPITER AVIONICS CORP. ICS Tie Line Isolation Transformer JA40-001 1/1 JA40-001 Connector Map Rev A.DWG TAT 1 2 3 4 5 6 7 8 9 ICS TIE LINE #1 HI ICS TIE LINE #2 HI ICS TIE LINE #3 HI ICS TIE LINE #4 HI CHASSIS GROUND ICS TIE LINE #1 LO ICS TIE LINE #2 LO ICS TIE LINE #3 LO ICS TIE LINE #4 LO P1 9 PIN FEMALE DMIN MATING CONNECTOR VIEW IS FROM REAR OF MATING CONNECTOR JAC DS 11-26-13 JAC KDV 11-27-13

JUPITER AVIONICS TEMPLATE AUTOCAD PORTRAIT SIZEA REV B.DWT

TITLE APPROVED PREPARED CHECKED L00N3 NCAGE CODE PART NO. SHEET DOC NO. CONFIDENTIAL & PROPRIETARY TO JUPITER AVIONICS CORP. ICS Tie Line Isolation Transformer JA40-001 1/2 JA40-001 Interconnect Rev A.DWG TAT JA40-001 INTERCONNECT WIRING NOTES NOTES ALL WIRE SIZE SHOULD BE 24 AWG MIN UNLESS OTHERWISE SPECIFIED. UNSHIELDED WIRE SHOULD BE SELECTED PER FAA AC43.13-1B CHANGE 1 PARA 11-76 TO 11-78. WIRE TYPES SHOULD BE IN ACCORDANCE WITH MIL-W-22759 AS DESCRIBED IN FAA AC43.13-1B CHANGE 1 PARA 11-85 AND 11-86 AND LISTED IN TABLE 11-11 OR 11-12. ALL SHIELDED CABLE SHOULD BE IN ACCORDANCE WITH MIL-DTL-27500 (REVISION H OR LATER). CONNECTION TO AIRFRAME GROUND SHOULD BE MADE WITH 20 AWG WIRE. LENGTH NOT TO EXCEED 3 FT (0.91 M). CABLE SHIELDS AT THE JA40-001 CONNECTOR PINS SHOULD BE TERMINATED TO AIRFRAME GROUND USING A TAG RING P/N: MS27741-5 OR EQUIVALENT. 2 1. 3

ICS TIE LINE #1 HI

ICS TIE LINE #1 LO HI LO ICS TIE LINE #1 1 6 ICS TIE LINE #2 HI ICS TIE LINE #2 LO HI LO ICS TIE LINE #2 2 7 ICS TIE LINE #3 HI ICS TIE LINE #3 LO HI LO ICS TIE LINE #3 3 8 ICS TIE LINE #4 HI ICS TIE LINE #4 LO HI LO ICS TIE LINE #4 4 9 CHASSIS GROUND 5 JA40-001 J1 P1 9 PIN FEMALE DMIN MATING CONNECTOR 2 3 2 CHASSIS GROUND 20 AWG 2 JUPITER AVIONICS TEMPLATE AUTOCAD PORTRAIT SIZEA REV B.DWT TITLE APPROVED PREPARED CHECKED L00N3 NCAGE CODE PART NO. SHEET DOC NO. CONFIDENTIAL & PROPRIETARY TO JUPITER AVIONICS CORP. ICS Tie Line Isolation Transformer JA40-001 2/2 JA40-001 Interconnect Rev A.DWG TAT

CENTER OF GRAVITY

WEIGHT: 0.37 lbs [0.17 Kg] MAX. 0.03in [0.8mm] 2.25in 57.2mm 1.22in 31mm 0.55in 14mm 32.3mm MAX 1.27in MAX 114.8mm MAX 4.52in MAX 3.51in MAX 89.2mm MAX 101.6mm 4.00in 7.6mm 0.30in 0.25in 6.4mm 1.80in 45.7mm TITLE CONFIDENTIAL & PROPRIETARY JUPITER AVIONICS TEMPLATE SOLIDWORKS LANDSCAPE SIZEA REV B.DRWDOT ICS Tie Line Isolation Transformer - 4 Channel JA40-001 Mechanical Installation Rev A.SLDDRW DOC. NO. 1/1 SHEET JA40-001 PART NO. L00N3 DRAWING NOT TO SCALE TO JUPITER AVIONICS CORP. APPROVED CHECKED TAT PREPARED N/A N/A MATERIAL: FINISH: NCAGE CODE UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES ANGLES ARE IN DEGREES TOLERANCES: 1 DEC PLACE: 0.1 2 DEC PLACE: 0.01 3 DEC PLACE: 0.005 ANGLES: 0.5 DEG 2.42in MAX 61.5mm MAX 2.61in MAX 66.3mm MAX JAC DS 11-26-13 JAC KDV 11-27-13

JA40-001 ICS Tie Line Isolation Transformer

Installation Manual Appendix B - �������ation Documents

JA40-001 ICS Tie Line Isolation Transformer

Installation Manual Rev B Page B2 B1 Airworthiness Airworthiness approval of the JA40-001 may require completion of a TCCA Major Modification Report per CAR STD (AWM) 571 Appendix L, or a FAA Form 337. The sample wording for a description of the work is provided to assist the Installing Agency in preparing Instructions for Continued Airworthiness (ICA) when replacing an existing Isolation Transformer with a Jupiter Avionics JA40-001 ICS Tie Line Isolation Transformer. This sample may be modified appropriately for new installations. It is the installer’s responsibility to determine the applicability of the method used. Installations performed outside Canada must follow the applicable aviation authority’s regulations. Sample Wording: Removed the existing [model] Isolation Transformer and replaced with a Jupiter Avionics JA40-001 ICS Tie Line Isolation Transformer in [aircraft location]. Installed in accordance with the JA40-001 Installation Manual, Revision [ ], and AC 43.13-2, Chapters 2, and 3. The JA40-001 interfaces with existing aircraft systems per the Installation Manual instructions. The JA40-001 Installation Manual provides detailed installation instructions and wiring diagrams (Section 2, and Appendices A and B). The JA40-001 does not require electrical power. Aircraft equipment list, weights and balance amended. Compass compensation checked and found to conform to applicable regulations. B2 Instructions for Continued Airworthiness Maintenance of the JA40-001 ICS Tie Line Isolation Transformer is “on condition” only. Refer to the JA40-001 Maintenance Manual. Periodic maintenance of the JA40-001 is not required. The following sample Instructions for Continued Airworthiness (ICA) provides assistance in preparing ICA for the Jupiter Avionics JA40-001 unit installation as part of a Type Certificate (TC) or Supplemental Type Certificate (STC) project to comply with CAR STD (AWM) 523/527/525/529.1529 or FAR 23/25/27/29.1529 “Instructions for Continued Airworthiness”. Items that may vary by aircraft make and model are shown in brackets (“[ ]”) and should be filled in as appropriate. Some of the checklist items do not apply, in which case they should be marked “N/A” (Not Applicable). Instructions for Continued Airworthiness, Jupiter Avionics JA40-001 ICS Tie Line Isolation Transformer in an [Aircraft Make and Model] 1. Introduction [Aircraft that has been altered: Registration number, Make, Model and Serial Number] Content, Scope, Purpose and Arrangement: This document identifies the Instructions for Continued Airworthiness for a Jupiter Avionics JA40-001 installed in an [aircraft make and model]. Applicability: Applies to a Jupiter Avionics JA40-001 installed in an [aircraft make and model]. Definitions/Abbreviations: None, N/A. Precautions: None, N/A. Units of Measurement: None, N/A. Referenced Publications: JA40-001 Installation Manual JA40-001 Maintenance Manual STC/TC # [applicable STC/TC number for the specific aircraft installation] Distribution: This document should be a permanent aircraft record.

JA40-001 ICS Tie Line Isolation Transformer

Installation Manual Rev B Page B3 2. Description of the System/Alteration Jupiter Avionics JA40-001 ICS Tie Line Isolation Transformer with interface to the intercom system and [include other equipment/systems as appropriate]. Refer to Appendix A of this manual for interconnect information. Refer to aircraft manufacturer approved interconnect for actual installation. 3. Control, Operation Information N/A 4. Servicing Information N/A 5. Maintenance Instructions Maintenance of the JA40-001 is ‘on condition’ only. Periodic maintenance is not required. Refer to the JA40-001 Maintenance Manual. 6. Troubleshooting Information Refer to the JA40-001 Maintenance Manual. 7. Removal and Replacement Information Refer to Section 2 of this manual - the JA40-001 Installation Manual. If the unit is removed and reinstalled, a functional check of the equipment should be conducted. 8. Diagrams Refer to Appendix A of this manual - the JA40-001 Installation Manual - for installation drawings and interconnect examples. 9. Special Inspection Requirements N/A 10. Application of Protective Treatments N/A 11. Data: Relative to Structural Fasteners JA40-001 and appropriate mounting hardware installation, removal and replacement should be in accordance with applicable provisions of AC 43.13-1B and AC 43.13-2A. 12. Special Tools N/A 13. This Section is for Commuter Category Aircraft Only A. Electrical loads: Refer to Section 1 of the JA40-001 Installation Manual. B. Methods of balancing flight controls: N/A. C. Identification of primary and secondary structures: N/A. D. Special repair methods applicable to the airplane: N/A. 14. Overhaul Period No additional overhaul time limitations. 15. Airworthiness Limitation Section N/A