Dacor 24GN Planning Manual
Read Online
Read the Dacor 24GN Planning Manual online using the built-in PDF viewer.
Text of the manual
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.15
Warming Oven/
Drop-In Cooktop
COMBINATION INSTALLATIONS
Warming Oven
Preference™/Millennia™ Cooktop
1 1/2" (38mm) Typical counter top
120VAC
Electrical
receptacle
9 1/8" (232mm) (All models except IOWO)
12 1/8" (308mm) (IOWO model only)
"A"
36"
(914mm)
"B"
2
3/4" (19mm) Min.
preference™/ Millennia™ cooktop with warming oven
Models
“A” Cabinet
Cutout Width
“B” Min.
Cabinet Width
Oven Overlays
24”
22 1/2” (572mm)
24” (610mm)
3/4” (19mm) Each Side;
1/2” (13mm) Top;
1/2” (13mm) Bottom
27”
25 1/2” (648mm)
27” (686mm)
30”
30” (762mm)
36”
34 3/8” (873mm)
36” (914mm)
IOWO24
22 9/16” (573mm)
27” (686mm)
N/A
NOTES:
1. 24” (610mm) minimum interior cabinet depth.
2. 3/4” (19mm) support platform (flush with cutout).
3.
1/8” (3mm) minimum clearance to adjacent cabinet
doors/drawers.
4.
For stacked warming ovens, see CI.20.
5.
The IOWO model cannot be stacked.
1/1