GCC Technologies LaserPro S400 Installation Manual
Read Online
Read the GCC Technologies LaserPro S400 Installation Manual online using the built-in PDF viewer.
Text of the manual
12V_24V External I/O board
Installation Guide
S400
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
June 28-2019, Version: 1.0
2
The parts for 12v_24v external I/O board have items below:
Notice:
S400 12v_24v External I/O board upgrade kit part number is LGCC-290115510G
1
2
3
4
5
6
7
8
9
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
2.1. Mount 24v power supply(item #1) by using 2 shorter screws(these 2 shorter screws belong to item #1,
see 2 red circles below for the position) on the back side of bracket (item # 2). Then mount 24v
power cable (item #7) to the left side of power supply (DC side, see the yellow circle below). Then
mount the AC cable (item #6) to the right side of power supply (AC side, see the green circles
below).
Open S400 main board side cover and mount the 24v power supply and bracket on the position
below. The 2 red circles below are to show the mounting position(two pictures below show the
same position, the left picture is from a longer distance and right picture is from a closer distance).
Using 3 screws (item #4, see 3 yellow circles below for screw positions) to mount the bracket.
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
Mount the wiring pcb (item #3) on top of bracket (item #2) by using 4 screws (item #4, see 4 red
circles below for the screw positions). Connect the JP33 signal cable (item #9, see the yellow circle
below)
The other side of JP33 signal cable (item #9) connect to main board(see the yellow circle below)
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
The 24v power cable (item #7) connects to the position below. The two yellow circles are the both
side of 24v power cable (item #7).
If user need to use 12v power, then change from 24v power cable (item #7) to be 12v power cable
(item #8) and connect to the positions below (the 2 yellow circles point the both sides of 12v power
cable)
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
The one side of AC power cable (item #6) connects to 24v power supply (the red circle below).
The other side of AC power cable (item #6) parallel connects to laser power supply AC (The two
red circles below are the same position. One picture is from a longer distance, one picture is a
closer distance). The AC cable screws are not easy to reach, so the laser power supply needs to be
removed the screws first(4 yellow circles below) and then mount back after connect the AC cables.
The cable protector (item #5) put to the back side of machine (the red circle below).
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
Remote Interlock Control Connection for 5272 mainboard
Connect the cable from JP24 to the JP33 on the mainboard
Connect the cable from JP43 to JP34 on the mainboard
We can connect the 12V power to the power supply on the laser engraver as show
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
The External Control Interface Board can be set to work with 5V or 12V signals
Set the jumpers to 5V or 12V accordingly in order to switch between 5V and 12V signals.
External Control Interface definitions:
Output 1: Normal low, On=High (In the duration of a job the signal is high)
Output 2: Normal High, On=Low (When Stop button is pressed, signal = low, when
processing job is finish, signal = high)
Adjust the jumper on To set the Output voltage
G
GNNDD
O
Ouuttppuutt 22
O
Ouuttppuutt 11
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
External Control Interface definitions:
Input 1: Laser On/Off (Disables/enables laser signal) Laser turns off if a hi signal is
provided
Input 2: Start/Stop (Triggers the Start/Stop function) Start
Control Modes
Switch mode
To use under Switch mode, we need to set the jumpers as follow:
Set the jumper of JP8&JP9 to the 1-2 position
Set the jumper of JP4&JP5 to the 1-2 position
JJPP99
JJPP88
JJPP44 JJPP55
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
External Control Interface definitions:
Under Switch mode:
Input I/O & GND
Input 1: Normal Open = Laser ON; Close = Laser OFF
Input 2: Close = Start/Stop (Triggers the Start/Stop function) Start
Control Modes
Electronic Control mode
To use under Electronic Control mode, we need to set the jumpers as follow:
Set the jumper of JP8 & JP9 to the 2-3 position
Set the jumper of JP4 & JP5 to the 2-3 position
JJPP99
JJPP88
JJPP44
JJPP55
IInnppuutt 11
G
GNNDD
IInnppuutt 22
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com
External Control Interface definitions:
Under Electronic Control mode:
Input I/O & GND (5V/12V)
Input 1: High = Laser Off
Low = Laser On
Input 2: Activates Start/Stop
G
GNNDD
IInnppuutt 22
IInnppuutt 11
Distributed by: Jorlink USA, Inc. | Tel.: (336) 288-1613 | [email protected] | www.JORLINK.com