Everet EVP412 Operation & User’s Manual

Specifications

Brand: Everet
Category: Security Camera
Model: EVP412
File Type: PDF
File Size: —
Pages: 39

Read Online

Read the Everet EVP412 Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

Qucik Start Guide

3 Dial Switch Settings (at the bottom of the camera) 4 PRODUCT HIGHLIGHTS 6 TECHNICAL SPECIFICATIONS 7 CAMERA INTERFACE 9 CAMERA DIMENSIONS 9 IR REMOTE CONTROLLER 10 OSD MENU 13 Webinterface 23 VISCA OVER IP 35 HOW TO USE VISCA OVER IP 35 SAFETY GUIDES 1. Before operation, please fully read and follow all instructions in the manual. 2. The camera power input range is 100-240 VAC (50-60Hz), ensure the power supply input within this rate before powering on. 3. The camera power voltage is DC12V/8W. We suggest you use it with the original power supply adapter or use PoE+ (IEEE802.3at) compatible switch. 4. Please keep the power cable, video cable and control cable in a safe place. Protect all cables especially the connectors. 5. Operational environment: 0℃-50℃, humidity less than 90%.To avoid any danger, do not put anything inside the camera, and keep away from the corrosive liquid. 6. Avoid stress, vibration and damp during transportation, storage and installation. 7. Do not detatch the camera housing and cover. For any service, please contact authorized Everet technicians. 8. Video cable and control cable should be individually shielded, and cannot be substituted with other cables. 9. Do not direct the camera lens towards strong light, such as the sun or the intensive light.

10. Use a dry and soft cloth to clean the camera housing. Applied with neutral cleaning agent

when there is need to clean. To avoid damage on the camera lens, never use strong or abrasive cleaning agents on the camera housing. 11. Do not move the camera by holding the camera head. To avoid mechanical trouble, do not rotate the camera head by hand. NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING. 12. Put the camera on fixed and smooth desk or platform, avoid leaned installation. 13. Power Supply Polarity (Drawing) Note: The video quality may be affected by the specific frequencies of electromagnetic fields. Never grasp the head of the camera, and never move the camera by hand when it is working, otherwise the camera will breakdown. PACKING LIST Check all bellow items when open the package: Camera 1 Power Adapter 1 Power Cable 1 RS232 Control Cable 1 USB 3.0 Cable 1 Remote Controller 1

Qucik Start Guide

1. Check if following products are in the box - Camera - DC12V input - Power supply cable - RS232 Cable - USB 3.0 Cable - IR Remote Control 2. Power on the camera with the 12V adapter or use a POE+ switch. PoE+ switch requirements: (PoE+ IEEE 802.3af/at compliant with total power of 126W up to 30W per port) Recommended unmanaged PoE+ network switches: - TP link TL-SG1008MP 8-port - Netgear GS16PP 16-port 3. Check if you get video output from HDMI or SDI on a display. NOTE: The default resolution of the camera is 1080P30. If your display does not support this resolution you can easily change the resolution with the IR remote control. Please go to chapter: IR Remote Controller in this manual and follow instructions ‘Change video output Resolution for SDI, HDMI and USB 3.0‘ on how to do this. 4. Check if you can Pan and Tilt the camera wit the IR remote controller. NOTE: if you cannot pan or tilt the camera. Please go to chapter: IR Remote Controller in this manual and follow instructions ‘SET Camera 1-4’ on how to do this. 5. Please check the default camera IP address (192.168.1.188) for operation in your network or simply change IP address in OSD menu settings using IR remote controller. Please go to chapter: ‘OSD Menu’ and follow instructions ‘Change IP address’ to see how to do this

Dial Switch Settings (at the bottom of the camera)

Dial Switch(ARM) SW-1 SW-2 Instruction 1 OFF OFF Updating mode 2 ON OFF Debugging mode 3 OFF ON Undefined 4 ON ON Working mode

Dial Switch (USB)

SW-5 SW-6 Instruction 1 OFF OFF Undefined 2 ON OFF Working mode 3 OFF ON Updating mode 4 ON ON Undefined

• Advanced ISP, 1/2.5 inch 8MP Sony sensor, providing 3840x2160 p30

• Ultra HD video resolution • 4K wide angle optical lens: 12x optical zoom and 2x digital zoom , with 72.5 degree field of view; • 4K video over IP, H.264, H.265 encoding; • IP, HDMI, 3G-SDI, USB video outputs interface • 3G-SDI compatible with Blackmagic Design SDI Level-B • White Balance, Exposure, Focus, Iris can be adjusted automatically or manually • Support POE: easy to use one RJ45 cable to get video, control and power supply • Special Focusing Algorithm: fast and precise focusing performance when zooming or moving • Smooth PTZ mechanical design, accurate pan tilt motor control • 128 presets supported • Standard Sony VISCA, VISCA over IP, PELCO-P, PELCO-D control protocol; IP VISCA over both TCP and UDP • Daisy chain supported, max 7 cameras connected in VISCA protocol • Image flip function, support upside-down installation • Supplied with functional IR remote controller • Fast video format switch: less than 3 seconds • Supported field upgrade for ISP, ARM, FPGA and USB • USB3.0 port compatible with USB2.0 output. • Support RS232/RS485/UVC control • Standard UVC1.5 protocol, seamlessly compatible with major video conferencing software and platform • Support IR transfer function, code of the third party remote controller can be transferred to the host via VISCA IN port, in case client’s development • OSD menu in English, IP address, streaming resolution and size can be set in OSD menu

1920*1080@3~30, 1280*720@3~30, 1024*576@3~30;

640*360@3~30 Sub Stream: 1280*720@3~30, 1024*576@3~30, 640*360@3~30. USB 3.0 1920*1080P60/50/30/25 1280*720P60/50/30 1280*720P25 1024*576P30 960*540P30 640*360P30 352*288P30 Video Interface HDMI (V1.4), 3G-SDI, USB 3.0, RJ45 Sensor 1/2.8” 8MP Sony CMOS sensor Zoom f 3.92~47.32mm(12X), F1.8- 2.8, View Angle: 72.5°(Far)-6.3°(Near) Rotation Angle Pan: -170° ~ +170°; Tilt: -30° ~ +90° Rotation Speed Pan: 0°~120°/s ; Tilt: 0°~80°/s Preset: Remote controller: 10; RS232: 128; Accuracy: 0.1° Control Port RS232, RS485, RJ45 VISCA over IP, USB3.0 (UVC1.5), USB2.0 (UVC1.1) Network Speed 1000M Video encode H.264/H.265(default: H.264)

Bit Rate Control

Variable Bit Rate, Constant Bit Rate Video Bit Rate 1024Kbps~16384Kbps IP Protocol TCP/IP, HTTP, RTSP, DHCP ,RTMP, Onvif(2.4), Visca over IP(TCP&UDP), HTML5, Visca, Pelco P, Pelco D POE Supported Daisy Chain Support RS232 serial daisy chain Minimum Lux 0.1 lux White Balance Auto/Indoor/Outdoor/Manual/One Push/ATW Exposure Auto/Manual/Shutter Priority /Iris Priority/Bright Focus Auto / Manual Iris Auto / Manual Electric Shutter Auto / Manual Gamma Supported WDR Supported BLC Supported 2D/ 3D Noise Reduction Supported Anti Flicker OFF/50Hz/60Hz Pan Tilt Flip Supported Input Voltage DC12V/12W PoE+ recommended (IEEE802.3at) Dimension 220mm×190mm×173mm Net Weight 1.5KG

3.IR Receiver Panel

4.Power Indicator Light 5.Dial Switch 6. Tripod Screw Hole 7. Installation Hole 8. RS232 control port (input) 9. RS232 control port(output) 10. HDMI port 11. 3G-SDI port 12. USB 3.0 13. RJ45 port (IP&NDI) 14. DC12V plug CAMERA DIMENSIONS

IR REMOTE CONTROLLER

POWER By pressing the POWER key when the camera is on, the camera will rotate and go in the ‘stand-by’ mode. When the camera is in stand- by mode and you Press the power button again, the camera will boot and automatically go back to the Default PTZ position. The Default PTZ position is the PTZ position of the camera when you turn it on for the first time. The only preset that overrules this Default PTZ position when the camera is rebooted, is the ‘0’ Preset. You can always go back to the Default PTZ position by pressing the OK button. NOTE: The above is only applicable when solemnly IR remote control is used to control PTZ camera. In situations where the EVKB-100 is used to control the camera Preset ‘1’ will overrule the HOME position. FREEZE (Not Supported in USB) Short press FREEZE key to freeze/ unfreeze the image. IRT (IR Transfer/IR Pass) Open / close the IR pass function. Once press the IRT key, the camera will receive and Pass the IR remote control signal to the codec/terminal (via VISCA IN port).

SETTING 1-4 CAMERAS

The SET keys are used to connect one of the CAM buttons to a specific camera. For example. If you have a EVP212, EVP220 and EVP230 and you want to configure them as follow: CAM1 = EVP212 CAM2 = EVP220 CAM 3 =EVP230 1. Point the IR to camera you would like to configure. 2. Long press one of the SET1 button for 3 seconds until the key light of one of the CAM buttons starts flickering red. 3. When the happens just let go of the SET button you were pressing. 4. Short press CAM1 button to configure for e.g. EVP212 to CAM1. Every time you press CAM1 you will be controlling the EVP212. You can follow these exact steps to configure other cameras. NOTE: If you want to configure more cameras to the same CAM number than you should SET all the cameras to CAM1. PRESET NUMBER KEY (1-9) Set preset: long press (3 seconds) the number key to set preset. Call preset: Short press the number key to run preset. CLR PRE (CLEAR PRESET) Press CLR PRE and then choose number key of the preset you like to clear. Long press CLR PRE to clear all presets. FOCUS KEY ( ON THE LEFT) With this button the focus of the camera can be controlled when it is in Manual focus mode. ZOOM KEY( ON THE RIGHT SIDE) = Zoom in = Zoom out NAVIGATE KEY: UP/DOWN/LEFT/RIGHT Under working mode, use navigate key to set the pan tilt, and select menu when enter OSD. OK Under working mode, short press OK to make the camera go back to Default PTZ position; and confirm the selection when enter OSD. AF: Auto Focus MF: Manual Focus RESET: Press 3 seconds to reset camera MENU: Enter OSD menu LEARN+LIMIT L key: Set the pan tilt left limit position. LEARN+LIMIT R key: Set the pan tilt right limit position. LEARN+LMT CLR key: Clear the limit position. BLC OFF/ BLC ON: Set backlight ON/OFF BRIGHT-/BRIGHT+: Set image brightness, only valid under bright priority exposure mode.

Change Video output resolution for SDI, HDMI

and USB 3. Long press one of the blue resolution buttons until the screen turns black. When the screen turns black let go of the button and the video output will automatically appear.

1. Press the MENU key on the IR remote controller, to enter the OSD menu as bellow:

2. After entering the main menu, use the UP/DOWN keys on the IR remote controller to navigate through the menu. Once selected, the main menu will change to blue background, and the right side will show all sub menu options. 3. Press the navigate RIGHT key to enter sub menu; use UP/DOWN key to select the submenu. use the LEFT/RIGHT key to select parameter. 4. Press the MENU key again to return to previous menu. Press the MENU key continuously to exit the OSD menu. Settings that have been changed are automatically saved.

Protocol lock: once set, above protocol setting will be

locked Default:OFF RS485 RS485 ON/OFF Default:OFF VISCA To select VISCA sources Optional from via COM and via IP(VISCA over IP) Default: OVER ALL LANGUAGE English Default:English

AUTO, MANUAL, SHUTTER, IRIS, BRIGHT

Default:AUTO SHUTTER Shutter speed:1/8~1/10000, only valid under manual mode Default:AUTO IRIS Iris setting: CLOSE~F1.5, only valid under manual mode Default:AUTO GAIN Gain setting:0dB~28dB , only valid under manual mode Default:AUTO BRIGHT Bright setting:0~15 Default:8 EBRIGHT Bright setting:0~15 only valid under bright priority mode. NOTE: this setting is meant to control the bright when using the EVKB-100 Default:8 WDR ON/OFF Default:OFF WDR Level WDR Level Default:1 BLC ON/OFF Default:OFF

AUTO, INDOOR, OUTDOOR, MANUAL, PUSH, ATW

Auto: Automatically detects light in the room and selects the best white balance option for you. Indoor: Preset settings for indoor camera use. Outdoor: Preset settings for outdoor camera use. Manual: You Set the white balance options based on Red and Blue gains. One-Push: Used in conditions where Auto White balance is unable to detect and use a white image to auto set the white balance. Basically, you fill the frame with what you know to be a white object (even under colored lighting), this is saved as the camera's "white" reference and camera now auto-white-balances using the new reference "white" instead of its internal reference. ATW: Auto Tracking White Balance ATW is a more dynamic version of AUTO white balance. It detects when your ambient lighting shifts significantly (such as moving from indoors to outdoors) and dynamically changes the AWB for you. Default:AUTO R/B GAIN Red/Blue gain level: 0~255, only valid under manual white balance mode. NOTE: 0db is 100 ISO | 6db is 200 ISO | 12db is 400 ISO | 24db is 800 ISO Default:AUTO FLICK Anti-Flicker setting:50/60HZ, to reduce the video flicker Default:50HZ DZOOM Turn on/off digital zoom (2x digital zoom) Default:OFF FOCUS Select focus mode: AUTO/MANUAL Default:AUTO

2D noise reduction: the bigger value, the less noise on

image, the lower resolution Default:OFF 3D NR 3D noise reduction: OFF/AUTO/0~4, the bigger value, the less motion noise on image, high value will cause image smear. Default:AUTO SHARPNESS Sharpness setting: 0~15, the higher value, edge of the image will be sharpened Default:AUTO CONTRAST Set contrast level Default:50HZ SATURATION Set saturation. Default:8 GAMMA Select gammar level Default:0 AF SENSITIVITY Optional:LOW/NORMAL/HIGH Default:NORMAL

SpeedByZoom: proportional speed, the bigger zoom, the

slowerspeed Default:ON FLIP.HOR Flip horizontal Default:OFF FLIP VER Flip vertical Default:OFF PT SPD Pan Tilt speed Default:18 ZOOM SPD Zoom speed Default:5 MENU MIR Turn on/off left/menu mirror function Default:NORMAL PRE FRZ Preset Freeze function Freeze last preset video image when switching between presets Default: OFF PRE PTSPD Pan Tilt Speed of the Preset Default: 7 PRE ZSPD Zoom speed of the Preset Default: 1

Once selected, press OK key to

confirm, if it is the selected video format, there is no change. 1080P50 1080I59.94 1080P30 720P60 1080P25 720P50 1080P59.94 720P30 1080P29.97 720P25 1080P24 720P59.94 1080I60 720P29.97

navigation button to select

item to set and using number button to set parameter. Press menu button to return. IP 192.168.001.188 MASK 255.255.255.000 GW (Gateway) 192.168.001.001 MAIN Stream 1920*1080 1280*720 1024*576 BIT RATE 10240~16384k SUB Stream 1280*720, 1024*576,640*360 BIT RATE 10240~16384k

Reset communication parameter to default

CAM RESET Reset camera parameter to default PT RESET Reset pan/tilt parameter to default ALL RESET Reset all parameter to default

Camera IR control address

USB USB firmware version CLIENT Default client end protocol: VISCA ARM VER ARM firmware version FPGA VER FPGA firmware version CAM VER Camera version RELEASE Software release date

Run a browser and input IP address (default IP address is 192.168.1.188) to enter login interface as seen

below. Default account Username: admin Password: admin NOTE: If you cannot enter the webinterface with the default IP address there are two common situations that could be causing this problem. PC is not in the same range as the default IP address of the camera - In this case you would need to change the Ethernet adapter settings of your PC to get in the same IP range ass the camera. Please check on the internet how to do this according to the OS system that you are using. PC and Camera are connected to a DHCP router. 1. Get into the OSD menu of the camera with the IR Remote controller. 2. Navigate to IP. 3. Set DHCP to ‘ON’ 4. Press on the menu button of the IR Remote controller until you exit. 5. Restart the Camera and wait until it is completely rebooted. 6. Follow steps 1 and 2, check the IP address and try to get access again in the webbrowser.

2. Live video image and control

After you have successfully logged in you will see the live video image of your camera as below. You will also be able to control following settings as you can see on the left image. 1. PTZ 2. Zoom 3. Focus 4. Focus mode 5. Pan/tilt speed 6. Focus speed 7. Zoom speed 8. Set Presets

3. Video Encode Settings

Set following settings 1. Enable/disable Main or Substream 2. Encode mode: H.264/H.265 3. Profile: Baseline, MP, HP 4. RTSP Address can used to get video feed in for instance VLC or other RTSP Decoders 5. Resolution chose the encoding resolution. 6. Set bitrate 7. Set Framerate. 8. Bitrate control: Variable or Constant Bitrate 9. Set I-Frame interval. NOTE: We suggest keeping the resolution and framerate the same as your decoding project to prevent unnecessary encoding process. The I-Frame we suggest to set double as high as the framerate unless you are capturing sports or events with lots of movements per second. In that case we suggest to keep it the same as the famerate.

4. Video Transmission

RTMP Enable RTMP streaming for e.g. YouTube or Facebook or any other RTMP address. RTMP address: streamurl/streamkey NOTE: The mainstream must be enabled for the NDI to work.

5. Image Adjust

Focus: Set camera to auto or manual focus. Enable or disable Digital Zoom.

Exposure mode: Auto, Manual, Iris Priority, Shutter Priority and Brightness Priority

White balance mode: Auto, Indoor, Outdoor, One Push, Auto Tracking (ATW), Manual

Image: enable mirror, flip, backlight compensation, WDR (wide dynamic range) and set Gamma

Image quality: configure brightness, sharpness, contrast and saturation

Noise reduction: includes 2D/3D reduction. There is an on/off option for 2D, and off/auto/1~4 options

for 3D.

In the image below you see the default Ethernet settings of the camera. This can be adjusted to your

network preferences. DHCP: Enable/Disable Enable DHCP if the camera is connected to a DHCP router that dynamically grants an IP address, netmask, gateway, and DNS. When DHCP is disabled you would need to manually set the IP address, netmask, gateway, and DNS. HTTP Port: 80 This is a standardized Port number to communicate between webclients and webservers. We suggest not to change this unless you have specific reasons. RTSP Port: 554 This is the communication port used to stream the RTSP stream to any RTSP receiving hardware or software. We suggest not to change this unless you have specific reasons. Visca over IP: 52381 This is the port number used to communicate PTZ commands over IP. This important if you want to control the camera with our Windows controller application, PTZ Controller and Bitfocus Companion.

7. Firmware upgrade

How to update Click “select file” icon, to open dialog box, select to open the file. First upgrade the ARM file and then the ISP file. Click “upgrade” to start the upgrade process. Only use upgrade files from everet.eu support website. Note: DO NOT power off or take other actions during the upgrade process, the camera will reboot automatically when the upgrade is finished. Afterwards login into webinterface and select “reset all” to reset the camera completely.

This is used for setting your login username and password. First Input the accountname, then input

password twice, click ok to finish settings. Please remember account and password, otherwise you are not able to login. USING VLC TO VIEW RTSP/RTMP VIDEO Default addresses RTSP - Default RTSP main streaming address: rtsp://192.168.1.188/stream/main - Default RTSP sub streaming address: rtsp://192.168.1.188/stream/sub RTMP - Default RTMP main streaming address: rtmp://192.168.1.188:1935/app/rtmpstream0 - Default RTMP sub streaming address: rtmp://192.168.1.188:1935/app/rtmpstream1 1. Run VLC Media Player. 2. Select Media > network stream, to show “open media” interface. 3. Input RTSP address in URL. 4. Click play to view the real time stream. Note: If there is to much delay, select the “more option” to change the buffer time (VLC default buffer time is 1000ms).

VISCA OVER IP

VISCA over IP means VISCA protocol over IP, to reduce RS232/RS485 cable layout (the controller must support VISCA over IP) Communication port spec: ● Control port: RJ45 Gigabit LAN ● IP protocol: IPv4 ● Transmit protocol: UDP ● IP address: set via web frontend or OSD menu ● Port address: 52381 ● Confirm send/transmission control: depending on applied program ● Range: in the same segment, not suitable for bridged network. ● Turn on camera: In the menu, set VISCA option to OVER IP HOW TO USE VISCA OVER IP VISCA Command It means commands from controller to peripheral equipment, when peripheral equipment receives commands, then return ACK. When commands executed, will return complete message. For different commands, camera will return different message. VISCA Inquiry It means inquiry from controller to peripheral equipment when peripheral equipment receives this kind of commands, it will return required message. VISCA Reply It means ACK, complete message, reply or error reply, sent from peripheral equipment to controller. Command format Enclosed is the message head and message format.

Data definition as specified:

Name Value (Byte 0) Value (Byte 0) Value (Byte 0) VISCA command 0x01 0x00 Stores the VISCA command. VISCA inquiry 0x01 0x10 Stores the VISCA inquiry. VISCA reply 0x01 0x11 Stores the reply for the VISCA command and VISCA inquiry, or VISCA device setting command. VISCA device setting command 0x01 0x20 Stores the VISCA device setting command. Control command 0x02 0x00 Stores the control command. Control reply 0x02 0x01 Stores the reply for the control command. Payload length Valid data length in Payload (1~16), is command length. For example, when valid data length is 16 byte Byte 2 : 0x00 Byte 3 : 0x10

Controller will save sequence number of each command, when one command sent, the sequence

number of the command will add 1, when the sequence number becomes the max value, it will change to 0 for next time. The peripheral equipment will save sequence number of each command, and return the sequence number to the controller. Payload According to Payload type, the following data will be saved. ● VISCA command ○ Save VISCA command packet ● VISCA inquiry ○ Save VISCA message packet ● VISCA reply ○ Save VISCA return packet ● VISCA device setting command ○ Save VISCA equipment setting command packet. Control command The following data is saved in control command payload Controlled reply The following data is saved in return command payload of control command. Delivery confirmation VISCA over IP uses UDP as transmission communication protocol, UDP communication message transmission is not stable. It is necessary to confirm delivery and resent in application. Generally, when controller sends a command to peripheral equipment, controller will wait for the return message then send the next command, we can detect and confirm if the peripheral equipment received the commands from return message’s lag time. If controller shows it is overtime, it will be marked as error transmission.

If controller shows it is overtime, resend the commands to check peripheral’s status. The resent

command sequence number is same as last command, the following chart will list the received message and status after resending the commands. Sequence chart as specified Sequence chart when command lost Sequence chart when returned message lost Note: Do not set IP address, subnet mask, gateway parameter in VISCA over IP command.