Everet EVP412 Operation & User’s Manual
Read Online
Read the Everet EVP412 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Qucik Start Guide
3
Dial Switch Settings (at the bottom of the camera)
4
PRODUCT HIGHLIGHTS
6
TECHNICAL SPECIFICATIONS
7
CAMERA INTERFACE
9
CAMERA DIMENSIONS
9
IR REMOTE CONTROLLER
10
OSD MENU
13
Webinterface
23
VISCA OVER IP
35
HOW TO USE VISCA OVER IP
35
SAFETY GUIDES
1. Before operation, please fully read and follow all instructions in the manual.
2. The camera power input range is 100-240 VAC (50-60Hz), ensure the power supply input
within this rate before powering on.
3. The camera power voltage is DC12V/8W. We suggest you use it with the original power
supply adapter or use PoE+ (IEEE802.3at) compatible switch.
4. Please keep the power cable, video cable and control cable in a safe place. Protect all
cables especially the connectors.
5. Operational environment: 0℃-50℃, humidity less than 90%.To avoid any danger, do not
put anything inside the camera, and keep away from the corrosive liquid.
6. Avoid stress, vibration and damp during transportation, storage and installation.
7. Do not detatch the camera housing and cover. For any service, please contact authorized
Everet technicians.
8. Video cable and control cable should be individually shielded, and cannot be substituted
with other cables.
9. Do not direct the camera lens towards strong light, such as the sun or the intensive light.
10. Use a dry and soft cloth to clean the camera housing. Applied with neutral cleaning agent
when there is need to clean. To avoid damage on the camera lens, never use strong or
abrasive cleaning agents on the camera housing.
11. Do not move the camera by holding the camera head. To avoid mechanical trouble, do
not rotate the camera head by hand.
NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING.
12. Put the camera on fixed and smooth desk or platform, avoid leaned installation.
13. Power Supply Polarity (Drawing)
Note:
The video quality may be affected by the specific frequencies of electromagnetic fields.
Never grasp the head of the camera, and never move the camera by hand when it is working,
otherwise the camera will breakdown.
PACKING LIST
Check all bellow items when open the package:
Camera
1
Power Adapter
1
Power Cable
1
RS232 Control Cable
1
USB 3.0 Cable
1
Remote Controller
1
Qucik Start Guide
1.
Check if following products are in the box
-
Camera
-
DC12V input
-
Power supply cable
-
RS232 Cable
-
USB 3.0 Cable
-
IR Remote Control
2.
Power on the camera with the 12V adapter or use a POE+ switch.
PoE+ switch requirements:
(PoE+ IEEE 802.3af/at compliant with total power of 126W up to 30W per port)
Recommended unmanaged PoE+ network switches:
-
TP link TL-SG1008MP 8-port
-
Netgear GS16PP 16-port
3.
Check if you get video output from HDMI or SDI on a display.
NOTE: The default resolution of the camera is 1080P30. If your display does not
support this resolution you can easily change the resolution with the IR remote
control. Please go to chapter: IR Remote Controller in this manual and follow
instructions ‘Change video output Resolution for SDI, HDMI and USB 3.0‘ on how to do
this.
4.
Check if you can Pan and Tilt the camera wit the IR remote controller.
NOTE: if you cannot pan or tilt the camera. Please go to chapter: IR Remote Controller
in this manual and follow instructions ‘SET Camera 1-4’ on how to do this.
5.
Please check the default camera IP address (192.168.1.188) for operation in your
network or simply change IP address in OSD menu settings using IR remote controller.
Please go to chapter: ‘OSD Menu’ and follow instructions ‘Change IP address’ to see
how to do this
Dial Switch Settings (at the bottom of the camera)
Dial Switch(ARM)
SW-1
SW-2
Instruction
1 OFF
OFF
Updating mode
2 ON
OFF
Debugging mode
3 OFF
ON
Undefined
4 ON
ON
Working mode
Dial Switch (USB)
SW-5
SW-6
Instruction
1 OFF
OFF
Undefined
2 ON
OFF
Working mode
3 OFF
ON
Updating mode
4 ON
ON
Undefined
• Advanced ISP, 1/2.5 inch 8MP Sony sensor, providing 3840x2160 p30
• Ultra HD video resolution
• 4K wide angle optical lens: 12x optical zoom and 2x digital zoom , with 72.5 degree
field of view;
• 4K video over IP, H.264, H.265 encoding;
• IP, HDMI, 3G-SDI, USB video outputs interface
• 3G-SDI compatible with Blackmagic Design SDI Level-B
• White Balance, Exposure, Focus, Iris can be adjusted automatically or manually
• Support POE: easy to use one RJ45 cable to get video, control and power supply
• Special Focusing Algorithm: fast and precise focusing performance when zooming or
moving
• Smooth PTZ mechanical design, accurate pan tilt motor control
• 128 presets supported
• Standard Sony VISCA, VISCA over IP, PELCO-P, PELCO-D control protocol; IP VISCA
over both TCP and UDP
• Daisy chain supported, max 7 cameras connected in VISCA protocol
• Image flip function, support upside-down installation
• Supplied with functional IR remote controller
• Fast video format switch: less than 3 seconds
• Supported field upgrade for ISP, ARM, FPGA and USB
• USB3.0 port compatible with USB2.0 output.
• Support RS232/RS485/UVC control
• Standard UVC1.5 protocol, seamlessly compatible with major video conferencing
software and platform
• Support IR transfer function, code of the third party remote controller can be
transferred to the host via VISCA IN port, in case client’s development
• OSD menu in English, IP address, streaming resolution and size can be set in OSD
menu
1920*1080@3~30, 1280*720@3~30, 1024*576@3~30;
640*360@3~30
Sub Stream:
1280*720@3~30, 1024*576@3~30, 640*360@3~30.
USB 3.0
1920*1080P60/50/30/25
1280*720P60/50/30
1280*720P25
1024*576P30
960*540P30
640*360P30
352*288P30
Video Interface
HDMI (V1.4), 3G-SDI, USB 3.0, RJ45
Sensor
1/2.8” 8MP Sony CMOS sensor
Zoom
f 3.92~47.32mm(12X), F1.8- 2.8, View Angle: 72.5°(Far)-6.3°(Near)
Rotation Angle
Pan: -170° ~ +170°; Tilt: -30° ~ +90°
Rotation Speed
Pan: 0°~120°/s ;
Tilt: 0°~80°/s
Preset:
Remote controller: 10; RS232: 128; Accuracy: 0.1°
Control Port
RS232, RS485, RJ45 VISCA over IP, USB3.0 (UVC1.5), USB2.0
(UVC1.1)
Network Speed
1000M
Video encode
H.264/H.265(default: H.264)
Bit Rate Control
Variable Bit Rate, Constant Bit Rate
Video Bit Rate
1024Kbps~16384Kbps
IP Protocol
TCP/IP, HTTP, RTSP, DHCP ,RTMP, Onvif(2.4),
Visca over IP(TCP&UDP), HTML5, Visca, Pelco P, Pelco D
POE
Supported
Daisy Chain
Support RS232 serial daisy chain
Minimum Lux
0.1 lux
White Balance
Auto/Indoor/Outdoor/Manual/One Push/ATW
Exposure
Auto/Manual/Shutter Priority /Iris Priority/Bright
Focus
Auto / Manual
Iris
Auto / Manual
Electric Shutter
Auto / Manual
Gamma
Supported
WDR
Supported
BLC
Supported
2D/ 3D Noise
Reduction
Supported
Anti Flicker
OFF/50Hz/60Hz
Pan Tilt Flip
Supported
Input Voltage
DC12V/12W PoE+ recommended (IEEE802.3at)
Dimension
220mm×190mm×173mm
Net Weight
1.5KG
3.IR Receiver Panel
4.Power Indicator Light
5.Dial Switch
6. Tripod Screw Hole
7. Installation Hole
8. RS232 control port (input)
9. RS232 control port(output)
10. HDMI port
11. 3G-SDI port
12. USB 3.0
13. RJ45 port (IP&NDI)
14. DC12V plug
CAMERA DIMENSIONS
IR REMOTE CONTROLLER
POWER
By pressing the POWER key when the camera
is on, the camera will rotate and go in the
‘stand-by’ mode. When the camera is in stand-
by mode and you Press the power button
again, the camera will boot and automatically
go back to the Default PTZ position. The
Default PTZ position is the PTZ position of the
camera when you turn it on for the first time.
The only preset that overrules this Default PTZ
position when the camera is rebooted, is the
‘0’ Preset. You can always go back to the
Default PTZ position by pressing the OK
button.
NOTE: The above is only applicable when
solemnly IR remote control is used to control
PTZ camera. In situations where the EVKB-100
is used to control the camera Preset ‘1’ will
overrule the HOME position.
FREEZE (Not Supported in USB)
Short press FREEZE key to freeze/ unfreeze the
image.
IRT (IR Transfer/IR Pass)
Open / close the IR pass function. Once press
the IRT key, the camera will receive and
Pass the IR remote control signal to the
codec/terminal (via VISCA IN port).
SETTING 1-4 CAMERAS
The SET keys are used to connect one of the
CAM buttons to a specific camera. For
example. If you have a EVP212, EVP220 and
EVP230 and you want to configure them as
follow:
CAM1 = EVP212
CAM2 = EVP220
CAM 3 =EVP230
1. Point the IR to camera you would like
to configure.
2. Long press one of the SET1 button for
3 seconds until the key light of one of
the CAM buttons starts flickering red.
3. When the happens just let go of the
SET button you were pressing.
4. Short press CAM1 button to configure
for e.g. EVP212 to CAM1.
Every time you press CAM1 you will be
controlling the EVP212. You can follow these
exact steps to configure other cameras.
NOTE: If you want to configure more cameras
to the same CAM number than you should SET
all the cameras to CAM1.
PRESET NUMBER KEY (1-9)
Set preset: long press (3 seconds) the number
key to set preset.
Call preset: Short press the number key to run
preset.
CLR PRE (CLEAR PRESET)
Press CLR PRE and then choose number key of
the preset you like to clear.
Long press CLR PRE to clear all presets.
FOCUS KEY ( ON THE LEFT)
With this button the focus of the camera can
be controlled when it is in Manual focus mode.
ZOOM KEY( ON THE RIGHT SIDE)
= Zoom in
= Zoom out
NAVIGATE KEY: UP/DOWN/LEFT/RIGHT
Under working mode, use navigate key to set
the pan tilt, and select menu when enter OSD.
OK
Under working mode, short press OK to make
the camera go back to Default PTZ position;
and confirm the selection when enter OSD.
AF: Auto Focus
MF: Manual Focus
RESET: Press 3 seconds to reset camera
MENU: Enter OSD menu
LEARN+LIMIT L key:
Set the pan tilt left limit position.
LEARN+LIMIT R key:
Set the pan tilt right limit position.
LEARN+LMT CLR key:
Clear the limit position.
BLC OFF/ BLC ON:
Set backlight ON/OFF
BRIGHT-/BRIGHT+:
Set image brightness, only valid under bright
priority exposure mode.
Change Video output resolution for SDI, HDMI
and USB 3.
Long press one of the blue resolution buttons
until the screen turns black. When the screen
turns black let go of the button and the video
output will automatically appear.
1. Press the MENU key on the IR remote controller, to enter the OSD menu as bellow:
2. After entering the main menu, use the UP/DOWN keys on the IR remote controller to navigate
through the menu. Once selected, the main menu will change to blue background, and the
right side will show all sub menu options.
3. Press the navigate RIGHT key to enter sub menu; use UP/DOWN key to select the submenu.
use the LEFT/RIGHT key to select parameter.
4. Press the MENU key again to return to previous menu. Press the MENU key continuously to
exit the OSD menu. Settings that have been changed are automatically saved.
Protocol lock: once set, above protocol setting will be
locked
Default:OFF
RS485
RS485 ON/OFF
Default:OFF
VISCA
To select VISCA sources
Optional from via COM and via IP(VISCA over IP)
Default:
OVER ALL
LANGUAGE
English
Default:English
AUTO, MANUAL, SHUTTER, IRIS, BRIGHT
Default:AUTO
SHUTTER
Shutter speed:1/8~1/10000, only valid under manual mode
Default:AUTO
IRIS
Iris setting: CLOSE~F1.5, only valid under manual mode
Default:AUTO
GAIN
Gain setting:0dB~28dB , only valid under manual mode
Default:AUTO
BRIGHT
Bright setting:0~15
Default:8
EBRIGHT
Bright setting:0~15 only valid under bright priority mode.
NOTE: this setting is meant to control the bright when using
the EVKB-100
Default:8
WDR
ON/OFF
Default:OFF
WDR Level
WDR Level
Default:1
BLC
ON/OFF
Default:OFF
AUTO, INDOOR, OUTDOOR, MANUAL, PUSH, ATW
Auto:
Automatically detects light in the room and selects the best white
balance option for you.
Indoor:
Preset settings for indoor camera use.
Outdoor:
Preset settings for outdoor camera use.
Manual:
You Set the white balance options based on Red and Blue gains.
One-Push:
Used in conditions where Auto White balance is unable to detect
and use a white image to auto set the white balance. Basically, you
fill the frame with what you know to be a white object (even under
colored lighting), this is saved as the camera's "white" reference and
camera now auto-white-balances using the new reference "white"
instead of its internal reference.
ATW: Auto Tracking White Balance
ATW is a more dynamic version of AUTO white balance. It detects
when your ambient lighting shifts significantly (such as moving from
indoors to outdoors) and dynamically changes the AWB for you.
Default:AUTO
R/B GAIN
Red/Blue gain level: 0~255, only valid under manual white balance
mode.
NOTE:
0db is 100 ISO | 6db is 200 ISO | 12db is 400 ISO | 24db is 800 ISO
Default:AUTO
FLICK
Anti-Flicker setting:50/60HZ, to reduce the video flicker
Default:50HZ
DZOOM
Turn on/off digital zoom (2x digital zoom)
Default:OFF
FOCUS
Select focus mode: AUTO/MANUAL
Default:AUTO
2D noise reduction: the bigger value, the less noise on
image, the lower resolution
Default:OFF
3D NR
3D noise reduction: OFF/AUTO/0~4, the bigger value, the
less motion noise on image, high value will cause image
smear.
Default:AUTO
SHARPNESS
Sharpness setting: 0~15, the higher value, edge of the
image will be sharpened
Default:AUTO
CONTRAST
Set contrast level
Default:50HZ
SATURATION
Set saturation.
Default:8
GAMMA
Select gammar level
Default:0
AF SENSITIVITY
Optional:LOW/NORMAL/HIGH
Default:NORMAL
SpeedByZoom: proportional speed, the bigger zoom, the
slowerspeed
Default:ON
FLIP.HOR
Flip horizontal
Default:OFF
FLIP VER
Flip vertical
Default:OFF
PT SPD
Pan Tilt speed
Default:18
ZOOM SPD
Zoom speed
Default:5
MENU MIR
Turn on/off left/menu mirror function
Default:NORMAL
PRE FRZ
Preset Freeze function
Freeze last preset video image when switching between
presets
Default: OFF
PRE PTSPD
Pan Tilt Speed of the Preset
Default: 7
PRE ZSPD
Zoom speed of the Preset
Default: 1
Once selected, press OK key to
confirm, if it is the selected video
format, there is no change.
1080P50
1080I59.94
1080P30
720P60
1080P25
720P50
1080P59.94
720P30
1080P29.97
720P25
1080P24
720P59.94
1080I60
720P29.97
navigation button to select
item to set and using number
button to set parameter.
Press menu button to return.
IP
192.168.001.188
MASK
255.255.255.000
GW (Gateway)
192.168.001.001
MAIN Stream
1920*1080 1280*720
1024*576
BIT RATE
10240~16384k
SUB Stream
1280*720, 1024*576,640*360
BIT RATE
10240~16384k
Reset communication parameter to default
CAM RESET
Reset camera parameter to default
PT RESET
Reset pan/tilt parameter to default
ALL RESET
Reset all parameter to default
Camera IR control address
USB
USB firmware version
CLIENT
Default client end protocol: VISCA
ARM VER
ARM firmware version
FPGA VER
FPGA firmware version
CAM VER
Camera version
RELEASE
Software release date
Run a browser and input IP address (default IP address is 192.168.1.188) to enter login interface as seen
below.
Default account
Username: admin
Password: admin
NOTE: If you cannot enter the webinterface with the default IP address there are two common
situations that could be causing this problem.
PC is not in the same range as the default IP address of the camera
-
In this case you would need to change the Ethernet adapter settings of your PC to get
in the same IP range ass the camera. Please check on the internet how to do this
according to the OS system that you are using.
PC and Camera are connected to a DHCP router.
1. Get into the OSD menu of the camera with the IR Remote controller.
2. Navigate to IP.
3. Set DHCP to ‘ON’
4. Press on the menu button of the IR Remote controller until you exit.
5. Restart the Camera and wait until it is completely rebooted.
6. Follow steps 1 and 2, check the IP address and try to get access
again in the webbrowser.
2. Live video image and control
After you have successfully logged in you will see the live video image of your camera as below.
You will also be able to control following settings as you can see
on the left image.
1. PTZ
2. Zoom
3. Focus
4. Focus mode
5. Pan/tilt speed
6. Focus speed
7. Zoom speed
8. Set Presets
3. Video Encode Settings
Set following settings
1.
Enable/disable Main or Substream
2.
Encode mode: H.264/H.265
3.
Profile: Baseline, MP, HP
4.
RTSP Address can used to get video feed in
for instance VLC or other RTSP Decoders
5.
Resolution chose the encoding resolution.
6.
Set bitrate
7.
Set Framerate.
8.
Bitrate control: Variable or Constant Bitrate
9.
Set I-Frame interval.
NOTE: We suggest keeping the resolution and framerate the same as your decoding
project to prevent unnecessary encoding process. The I-Frame we suggest to set
double as high as the framerate unless you are capturing sports or events with lots of
movements per second. In that case we suggest to keep it the same as the famerate.
4. Video Transmission
RTMP
Enable RTMP streaming for e.g. YouTube or Facebook or any other RTMP address.
RTMP address: streamurl/streamkey
NOTE: The mainstream must be enabled for the NDI to work.
5. Image Adjust
Focus: Set camera to auto or manual focus. Enable or disable Digital Zoom.
Exposure mode: Auto, Manual, Iris Priority, Shutter Priority and Brightness Priority
White balance mode: Auto, Indoor, Outdoor, One Push, Auto Tracking (ATW), Manual
Image: enable mirror, flip, backlight compensation, WDR (wide dynamic range) and set Gamma
Image quality: configure brightness, sharpness, contrast and saturation
Noise reduction: includes 2D/3D reduction. There is an on/off option for 2D, and off/auto/1~4 options
for 3D.
In the image below you see the default Ethernet settings of the camera. This can be adjusted to your
network preferences.
DHCP: Enable/Disable
Enable DHCP if the camera is connected to a DHCP router that dynamically grants an IP address,
netmask, gateway, and DNS. When DHCP is disabled you would need to manually set the IP address,
netmask, gateway, and DNS.
HTTP Port: 80
This is a standardized Port number to communicate between webclients and webservers. We suggest
not to change this unless you have specific reasons.
RTSP Port: 554
This is the communication port used to stream the RTSP stream to any RTSP receiving hardware or
software. We suggest not to change this unless you have specific reasons.
Visca over IP: 52381
This is the port number used to communicate PTZ commands over IP. This important if you want to
control the camera with our Windows controller application, PTZ Controller and Bitfocus Companion.
7. Firmware upgrade
How to update
Click “select file” icon, to open dialog box, select to open the file. First upgrade the ARM file and then
the ISP file. Click “upgrade” to start the upgrade process. Only use upgrade files from everet.eu
support website.
Note: DO NOT power off or take other actions during the upgrade process, the camera will reboot
automatically when the upgrade is finished. Afterwards login into webinterface and select “reset all”
to reset the camera completely.
This is used for setting your login username and password. First Input the accountname, then input
password twice, click ok to finish settings. Please remember account and password, otherwise you are
not able to login.
USING VLC TO VIEW RTSP/RTMP VIDEO
Default addresses
RTSP
-
Default RTSP main streaming address: rtsp://192.168.1.188/stream/main
-
Default RTSP sub streaming address: rtsp://192.168.1.188/stream/sub
RTMP
-
Default RTMP main streaming address: rtmp://192.168.1.188:1935/app/rtmpstream0
-
Default RTMP sub streaming address: rtmp://192.168.1.188:1935/app/rtmpstream1
1. Run VLC Media Player.
2. Select Media > network stream, to show “open media” interface.
3. Input RTSP address in URL.
4. Click play to view the real time stream.
Note: If there is to much delay, select the “more option” to change the buffer time (VLC default buffer
time is 1000ms).
VISCA OVER IP
VISCA over IP means VISCA protocol over IP, to reduce RS232/RS485 cable layout (the controller must
support VISCA over IP)
Communication port spec:
● Control port: RJ45 Gigabit LAN
● IP protocol: IPv4
● Transmit protocol: UDP
● IP address: set via web frontend or OSD menu
● Port address: 52381
● Confirm send/transmission control: depending on applied program
● Range: in the same segment, not suitable for bridged network.
● Turn on camera: In the menu, set VISCA option to OVER IP
HOW TO USE VISCA OVER IP
VISCA Command
It means commands from controller to peripheral equipment, when peripheral equipment receives
commands, then return ACK. When commands executed, will return complete message.
For different commands, camera will return different message.
VISCA Inquiry
It means inquiry from controller to peripheral equipment when peripheral equipment receives this
kind of commands, it will return required message.
VISCA Reply
It means ACK, complete message, reply or error reply, sent from peripheral equipment to controller.
Command format
Enclosed is the message head and message format.
Data definition as specified:
Name
Value (Byte
0)
Value (Byte
0)
Value (Byte 0)
VISCA
command
0x01
0x00
Stores the VISCA command.
VISCA inquiry
0x01
0x10
Stores the VISCA inquiry.
VISCA reply
0x01
0x11
Stores the reply for the VISCA
command and VISCA
inquiry, or VISCA device setting
command.
VISCA device
setting
command
0x01
0x20
Stores the VISCA device setting
command.
Control
command
0x02
0x00
Stores the control command.
Control reply
0x02
0x01
Stores the reply for the control
command.
Payload length
Valid data length in Payload (1~16), is command length.
For example, when valid data length is 16 byte
Byte 2 : 0x00
Byte 3 : 0x10
Controller will save sequence number of each command, when one command sent, the sequence
number of the command will add 1, when the sequence number becomes the max value, it will
change to 0 for next time. The peripheral equipment will save sequence number of each command,
and return the sequence number to the controller.
Payload
According to Payload type, the following data will be saved.
● VISCA command
○ Save VISCA command packet
● VISCA inquiry
○ Save VISCA message packet
● VISCA reply
○ Save VISCA return packet
● VISCA device setting command
○ Save VISCA equipment setting command packet.
Control command
The following data is saved in control command payload
Controlled reply
The following data is saved in return command payload of control command.
Delivery confirmation
VISCA over IP uses UDP as transmission communication protocol, UDP communication message
transmission is not stable. It is necessary to confirm delivery and resent in application.
Generally, when controller sends a command to peripheral equipment, controller will wait for the
return message then send the next command, we can detect and confirm if the peripheral equipment
received the commands from return message’s lag time. If controller shows it is overtime, it will be
marked as error transmission.
If controller shows it is overtime, resend the commands to check peripheral’s status. The resent
command sequence number is same as last command, the following chart will list the received
message and status after resending the commands.
Sequence chart as specified
Sequence chart when command lost
Sequence chart when returned
message lost
Note: Do not set IP address, subnet mask, gateway parameter in VISCA over IP command.