200759_2 TB Jan 2021
Installation & Operating Instructions
For The Evolution 5 Gas Stove MK2
Remote or Manual Control
Conventional, Top or Rear Flue, Natural Gas Stove
IT IS A REGULATION THAT THESE INSTRUCTIONS ARE HANDED TO THE
CUSTOMER AFTER THE INSTALLATION IS COMPLETE. IT IS ALSO THE
RESPONSIBILTY OF THE INSTALLATION ENGINEER TO ENSURE THE
CUSTOMER IS ABLE TO FULLY OPERATE THE APPLIANCE AND IS AWARE
OF ANY CLEANING OR MAINTENANCE REQUIRMENTS.
Please note: Gas installations MUST only be carried out by installers who
are Gas Safe registered.
Warning - Appliance should not be used if the glass in the door is
cracked, damaged or broken.
This product is not suitable for primary heating purposes.
Chimney closure plates are not supplied
200759_2 Issue 3
2
Contents
Introduction
3
Packing List
3
Specification
4
Dimensions
4
Hearth Requirements
5
Chimney Requirements
6
Assembly
Base Skirtings
7
Burner Installation
8
Mica Board Installation
9
Connecting the TTB Sensor
10
Ceramics Index
11 - 12
Positioning the logs
13
Gas Connection & Pressure Testing
14
Spillage Testing
15
Operating the Stove Slide Control Version
16
Operating the Stove Remote Control Version with Display
17 - 25
Maintenance / Cleaning / Curing the Paint
26
Trouble-shooting / Servicing
27 - 28
Commissioning Form
29
Guarantee
30
Energy Efficiency Rating
31 - 32
200759_2 Issue 3
3
Introduction
THANK YOU FOR PURCHASING A BROSELEY GAS STOVE
Broseley Fires Ltd was founded as an appliance and design development and
manufacturing company in 1975.
Since then we have built up an enviable reputation for the quality, reliability and fuel
efficiency of our stoves.
These instructions have been carefully prepared to guide the installer and end-user
through the relevant methods and standards for installation of your new Gas Stove.
Correctly installed and operated, your stove will give you many years of warmth and
reliability. Therefore, we would suggest that you read the whole instruction manual prior
to handing it to your installer. That way you will have a clearer picture of what is involved.
It is required by law that the complete assembly, installation and commissioning of gas
stoves is carried out by a professionally qualified and accredited gas fitter listed on the
“Gas Safe” register.
THE INSTALLATION MUST BE IN ACCORDANCE WITH THE ‘GAS SAFETY
INSTALLATION AND USE REGULATIONS’ IN CONJUNCTION WITH THESE
INSTRUCTIONS AND THE RELEVANT ‘BRITISH STANDARDS CODES OF
PRACTICE’ REQUIREMENTS AND THE RELEVANT ‘LOCAL AND NATIONAL
BUILDING REGULATIONS’. A COMMISSIONING CERTIFICATE MUST BE LEFT
WITH THE END CUSTOMER UPON FINAL COMPLETION AND THE
COMMISSIONING FORM COMPLETED IN THE BACK OF THESE INSTRUCTIONS.
Packing List
Stove Box
Fibre Box (Packed outside Stove)
1 x Stove body (with burner and Mica boards fitted)
1 x Main fuel bed
1 x Flue spigot
3 x Loose logs
3 x Flue spigot fixings
1 x Allen key (for door lock)
Remote Control Version only
1 x Instruction manual
1 x Remote handset and batteries
Chimney closure plates are not supplied
200759_2 Issue 3
4
Specification
Heat Input (Gross)
5.7kW
Gas Category
I2H
Supply Pressure
20 mbar
Gas Rate
0.538 m3/hr
Injector Type
Stamped E5
Flue diameter
125mm (5”)
Country of destination
GB, IE
Efficiency Class
Class 1
Nominal Output
4.3kW
NOx
130 mg/kWh (GCV)
Please note this product is designed to only use natural gas G20.
Dimensions
WEIGHT 90 Kg
All dimensions are in millimetres.
•
All parts of this appliance become hot during normal use.
•
All parts of the appliance should be considered ‘working surfaces’.
The efficiency of this appliance has been tested to BS613 and a result of 83%
NET (74.7% GROSS). This efficiency value has been verified by Kiwa (0558). This
efficiency value can be used for SAP (Standard Assessment Procedure) for
energy rating of UK dwellings.
200759_2 Issue 3
5
Hearth Requirements
The appliance needs to be located onto a solid non-combustible hearth with a minimum
thickness of 12mm. The hearth must be capable of withstanding the weight of the
appliance.
NB Side measurements taken from the Lid of the stove (Dimension E on page 4):
Rear measurement taken from the dilution box
Ensure all minimum clearances to combustible materials are complied with as
below:
Hearth Protrusion (in front of the appliance)
50mm
Shelf Distance (above the stove)
300mm
The specified minimum clearances provide the minimum distance to combustible
and non-combustible materials. If the appliance is intended to be installed into a non-
combustible opening, the clearances to the sides and above can be reduced.
However it is recommended that the specific minimum clearances are maintained,
irrespective of the materials used in the construction of the opening. This has been
tested and approved, to allow adequate air flow and access to the controls, as well
as allowing access for smoke tests and future maintenance of the flue and the
appliance.
The clearance to the rear of the appliance must always be a minimum of
50mm. Clearances to combustible materials cannot be reduced
Please note the gas supply connection to the appliance is to the right hand side
rear of the stove. The connection requires an 8mm-diameter semi-rigid pipe, not
more than 1 meter in length.
Additional Requirements
•
Curtains should not be positioned above the appliance at a distance of less than
the minimum specified for shelves
•
An additional guard is to be used to take account of the special hazards that exist
in nurseries and other places where there are young children or aged or infirm
persons present.
200759_2 Issue 3
6
Chimney Requirements
Please note Broseley Fires do not provide flue pipes, closure plates or any other
associated accessory.
Top or Rear Flue Outlet
The stove must be installed in accordance with current gas and buildings regulations
BS5871: Part1. The appliance can be installed in any adequate area suitable for solid
fuel fires and stoves. It can use a class 1, class 2 and pre-cast flue.
For pre-cast flue installations it is ESSENTIAL that a sealed connection is made into the
actual flue system (a void behind a closure plate is not permitted). Please refer to the
codes of best practice for further advice on pre-cast flues. Before you install the stove,
make sure the chimney flue outlet is correctly positioned to align with the flue outlet on
the stove and that the chimney is in good condition. If not, a chimney liner must be
installed or a suitable class II gas flue used. A draught is necessary to ensure the
products of combustion are fully evacuated.
It is recommended that the flue run is as straight as possible. The flue must have a
minimum vertical height of 3 metres to ensure adequate draught. You can have a
maximum of four bends in the run, each bend must not exceed 45° and an
additional metre of vertical flue should be provided for each bend. Ideally you
should have a minimum vertical section of 600mm before any bend immediately
off the top of the appliance, however it is permitted to use a 45° bend straight off
the appliance provided you have an adequate flue draft.
Prior to installation, the installer should ensure that the flue is free from obstruction and
any dampers must be fixed in a permanently open position. Ensure the chimney is not
closed and that it has been swept and subsequently smoke tested.
Make sure that rain, birds or any foreign body cannot get into the chimney to cause
damage or blockage. This problem can normally be overcome by fitting an approved gas
cowl. It is essential for the effective running of your stove that the chimney draws
properly to allow the products of combustion to escape.
VENTILATION (GB ONLY)
The gas stove is rated at less than 7kw input and therefore does not normally require
additional ventilation in the room (BS5871 – part II).
Flue Spigot Connection
Attach the supplied 5” diameter spigot to the top or rear of the stove using the three
M6x40 bolts and washers provided. The blanking plate (supplied) must be fitted over the
remaining flue outlet using 3 off m6 Countersunk screws.
200759_2 Issue 3
7
Assembly – Base Skirting
To make the gas supply connection (and also to replace batteries) on the stove you will
first need to remove the base skirting’s.
There are three skirting’s in total (one either side and one at the front). The side skirting’s
are held in place by a key slot and a magnet, to remove simply slide the skirting away
from you (towards the back of the stove) and pull free. The front skirting is held in place
by two fixings which can be accessed by opening the door.
Side View
Front View
All three skirting’s will need to be removed to allow access to the gas supply connection.
On the remote control version the right skirting also covers the main valve, this valve
contains batteries which will need to be replaced from time to time. On the manual
control version the left skirting allows access to the battery compartment which also
contains a battery for ignition purposes (again this will need to be replaced from time to
time).
200759_2 Issue 3
8
Assembly - Burner Installation
The burner will come pre-fitted, however please ensure all components are present and
fitted as per the information below to ensure nothing has moved (or become damaged)
in transit. You will need a 10mm socket for the burner and allen keys for the door when
fitting / replacing these items.
1) Remove the stove body from its packaging and stand it in position.
2) To open the door, remove the screw located above the handle (using allen key). The
door will now be free to open.
3) Slider Control Version Only. Ensure the front skirt has been removed, with the burner
completely inside the combustion chamber and control lever facing downwards
rotate the burner into position. Align the burner with the fixings points as below and
fasten in position. Reconnect wires to battery compartment and refit front skirt.
4) Remote Control Version Only. Insert the burner with the remote valve first followed
by the other end of burner. Locate in position as below and fasten in place
5) Fasten the burner into position using two (2) M6x40 bolts and washers provided.
6) The stove base plate and ceramic rods can now be fitted. The base plate rests on
the base of the stove whilst the ceramic rods fit into the cut outs in the burner bracket
as pictured.
200759_2 Issue 3
9
Assembly – Mica Board Installation
As with the burner, the Mica boards will be
pre-fitted into the stove. The information
below will assist with the removal/re-
installation should they need to be removed
for maintenance purposes.
First fit the rear mica board in front of the
burner bracket as shown opposite
Rest the top mica board (2) onto the rear,
whilst holding the top mica in position, insert
the LHS board.
Finally fit the remaining side mica board (4) and
allow the top board to rest down onto it (the top
board should now be supported by both the side and
rear mica boards).
200759_2 Issue 3
10
Assembly - Fitting Pilot to Valve and TTB sensor
MANUAL VERSION
With the burner installed, thread the 2 x TTB wires from the pilot / thermocouple to the
rear of the stove. Attach the two spade connections to the TTB which is fitted to the
bracket shown in Fig 1. Attach the bracket to rear panel of the stove by inserting the
keyhole cut-outs over the existing screw heads and drop down to final position. Tighten
screws if required. Ensure the white fibre is between the stove and bracket.
.
REMOTE VERSION
Pilot and electrode connections
Manual Connection to Valve
TTB wire into valve (First set of holes)
NOTE:- Please ensure the TTB sensor is correctly seated down into the holder and not
pushed up. If the TTB touches the bracket in anyway it could cause the sensor to short
circuit and the valve will not work. It is also essential that the TTB wire into the valve is
not disturbed or removed, if this wire is not making a good connection into the valve it
will simulate an error and the valve will not operate with the handset showing an
ERROR code. The power source should be disconnected prior to ANY servicing taking
place. Never remove the TTB sensor or burner without disconnecting the power
source to the valve
Rear View of TTB
bracket
TTB Spade Connection
200759_2 Issue 3
12
Assembly – Ceramics Index
Ceramic Index 2 of 2
Front Log
Right hand log with split
Rear Log
Final Assembly
200759_2 Issue 3
13
Assembly - Positioning the Logs
Only the ceramics supplied with this appliance should be used. The ceramics should
only be laid as described. Before any ceramics are placed in position ensure that the
pilot is not obstructed and the burner is operating correctly. Broseley Fires Ltd accepts
no responsibility for any injury sustained whilst handling hot ceramics. Ceramics which
are placed other than in accordance with these instructions will be the sole responsibility
of the fitter to rectify and Broseley Fires will not be liable for any associated costs.
1: Place the main fuel bed onto the base plate
covering the burner as shown in Fig 1
Fig 1
2: Locate the front log on the two base location
on the main fuel bed so the log sits as shown
in Fig 2
Fig 2
3: Locate the right hand side log (with split) on
the rear base locating area and ensure the
front of the log sits in the grove on the front log
as shown in Fig 3
Fig 3
4: Finally position the rear log on the rear
stand-off of the main bed and the stand-off on
the right hand log. Ensure the left hand side of
the rear log sits in the location area of the
main fuel bed (toward the rear of the stove).
Fig 4
200759_2 Issue 3
14
Assembly - Gas Connection & Pressure Testing
A minimum 15mm-diameter gas supply pipe must be used to within 1 metre of the
installation with the final connection to the stove to be completed with the suitable 8mm
semi-rigid gas pipe. The 8mm pipe should be connected to the inlet of the gas valve
using the nut and 8mm olive provided. Support the control whilst finally tightening the
supply pipe.
The gas supply connection to the appliance is located at the right hand side rear (remote
version) and left hand side rear (slide control) of the stove. The connection requires an
8mm-diameter semi-rigid pipe, not more than 1 meter in length. This connection is a
compression fitting, sealant should never be used (as this can potentially cause a
blockage).
Pressure Testing
Always make sure that there is adequate gas pressure and volume to the stove. The
relevant pressures are on the ID plate.
1. For natural gas, this is 20mbar measured at the inlet connection to the stove
with the appliance in the full rate position.
2. Ensure that the gas pressure to the stove is maintained when it is operating at
the same time as other appliances in the building and that a suitable pressure
gauge is used i.e. a manometer. If the gas pressure is not as per above it will be
the sole responsibility of the fitter to rectify and Broseley Fires will not be liable for
any associated costs.
3. All figures obtained during pressure testing should be recorded on the
commissioning form found at the end of these instructions.
Ventilation (GB only)
This gas stove is rated at less than 7kw input and therefore does not normally require
additional ventilation in the room (BS5871 – part II).
200759_2 Issue 3
15
Spillage Testing
A Spillage Test MUST be carried out before the installed fire is left with the customer.
Carry out the test by first closing all doors and windows in the room containing the fire.
Ensure that the fire is burning at full rate for a minimum of 10-15 minutes.
Using a lighted smoke match, run it along under the rear edge of the stove. The draught
diverter box is situated at the rear of the stove, the entry being in the rear panel for the
stove. Observe the smoke being drawn into the dilution box. After 10 minutes repeat the
test
If there is an extractor fan in a nearby room the spillage test must be repeated with the
fan running and all connecting doors between the fire and fan left open.
If there are problems, the chimney / flue may require attention, see “Chimney
Requirements” section.
Spillage Monitoring System
This appliance is fitted with an oxygen depletion-sensing pilot. This is designed to shut
down the fire within a safe period if there is an excessive build up of products of
combustion within the stove. On the rear of the stove fitted to the dilution box is a TTB
Disc Stat which monitors any spillage from the stove into the room, if the flue path
suffered severe blockage and / or ventilation was severely impeded this safety device
would also interrupt the gas supply to the stove and switch the appliance off.
THE FOLLOWING ARE IMPORTANANT WARNINGS RELATIVE TO THE SPILLAGE
MONITORING SYSTEM
1. The installer must not attempt any adjustments to the spillage monitoring system.
2. There must be no attempt to disable the spillage monitoring system.
3. It is not possible to replace individual parts of the pilot assembly on the appliance
only a complete pilot assembly (including thermocouple) may be fitted in the
event of a replacement being necessary. When the pilot is replaced, only
complete and original manufactures’ parts must be fitted.
4. Should the appliance turn itself off, wait for a minimum of 3 minutes before
attempting to re-light. In the event of your stove tripping out, consult your
installation engineer to have the flue / chimney checked.
In adverse conditions and when the flue is extremely cold it is possible the products of
combustion may build up inside the stove and not exit via the flue ways correctly, in
this scenario the ODS will activate and turn off the burner. If this occurs try to light the
burner again, this could take several attempts in order to get sufficient heat / draw in
the flue so the products of combustion can leave the stove correctly.
200759_2 Issue 3
16
Operating the Stove - Manual Control Version
It is important to read these instructions thoroughly before lighting the stove.
The control for ignition, low and high setting is located on the front of the stove, the
indicators in the control shows the burner position i.e. ignition, low, high or off
The pilot light is located at the front left corner of the fuel bed.
If the Flame Supervision Device Actuating Flame (the pilot light) is extinguished by
intention or not, no attempt should be made to re-light until 3 minutes have elapsed.
IGNITING THE PILOT AND USING THE LOW, HIGH AND OFF FUNCTION
1. From the start position, pull the handle out to the ignition point.
2. Whilst holding the handle in this position a continuous clicking
sound should be heard. This is the spark electrode attempting
to light the gas from the pilot. Hold in this position until the
pilot and burner are lit.
3. Once the pilot and burner are lit keep the handle at the
ignition point for 15-20 seconds, then release.
4. Repeat above steps if the burner extinguishes when the
handle is released. To select the burners low flame setting,
gently push the handle towards the fire until the single l is
aligned below the ash lip as shown right.
5. To select the burner’s high setting, gently push the handle
towards the stove body, you will notice a slight resistance once
you are about to engage the high setting of the burner. Once
at this point the handle should be pushed a little further to
lock it into the high setting.
6. From the high setting you can select low by pulling the handle
away from the stove and out of the high setting lock.
EXTINGUISHING THE STOVE FULLY
1. From any heat setting, push the handle towards the stove
and lock into the off position. You will feel resistance at the
high setting and then off setting, once locked into the off
positon the stove will fully extinguish within a few seconds. It
is advisable to leave the handle in this position when the
appliance is not in use.
200759_2 Issue 3
17
Operating the Stove - Remote Control Version
Quick start user instructions
This control is situated on the lower right hand side of your fire. The drawing below
shows the main features of the control.
The control requires 3 AA size alkaline batteries to be inserted under the battery
compartment cover. The orientation of these is shown moulded into the battery
compartment.
The power of the burner can be adjusted up and down by pressing the – and + buttons.
After fitting the batteries and replacing the cover the fire can now operate. Slide the
power isolator switch to the right to the on / I position.
To start the fire, press the power button and hold for 1 second then release. The burner
will within around 1 to 10 seconds, adjust to the maximum power setting,
To stop the fire, simply press the power button again and the burner will stop.
If you are not intending to use the fire for a long period (i.e. over summer time months)
the battery life can be extended even more by sliding the isolator switch to the left (away
from the “on” / “I” position, symbol 0).
200759_2 Issue 3
18
Operating the Stove - Remote Control Version
Handset
Ensure the power isolator switch on the front corner of Fire Control is in the on position I.
NOTE: For safety reasons a button must be pressed and released for the command to
be recognized. Keeping hold of a button when pressing (unless otherwise instructed) will
not be recognized as a command press.
Grasp around the handset to unlock its functions. The green unlock light will illuminate to
show when the handset is unlocked and ready to accept commands. (N.B. Keep a grip
of handset to keep it unlocked, to continue to operate the command buttons)
Mode – MAN (Manual), Zzz (Snooze),
thermostat or timed.
Time (12hour or 24 hr
display)
In Range of fire
(missing if not in
range or if Fire
Control turned off)
Room Temperature
Handset Unlocked
when Illuminated
To change handset
settings (see
handbook)
Press to increase flame
Power button – To start the fire (after following the instructions of the previous page) with one hand grasp around
the rear of both sides of the button area control. The green unlock light will illuminate. Keep the handset held to
keep the control unlocked, to enable operation of the buttons. Then with the other hand touch and hold a finger on
the power button for about 3 seconds. (A short beep and a flash of the unlock light will happen upon touching.)
When the word “pilot” appears at the bottom left hand corner of the display, immediately release the power button.
(A second flash of the unlock light and a longer beep will also sound at the time to release the power button). The
Fire should be lit within a few seconds. (N.B If power button is held for more than a few seconds after second
flash/beep/word pilot appears; the command is ignored for safety reasons. Similarly if it is released too soon before
the word pilot appears, the command is also ignored. With this system, the control has been designed to ensure
that only intended ignition of the fire occurs.) To stop – with handset held to unlock it, press then release power
button.
Press to decrease flame
To change mode (see
handbook)
Light sensor (for
display back light)
Battery condition –
RC handset, FC fire
control
Gas fire burner status
Day of the week
200759_2 Issue 3
19
Operating the Stove - Remote Control Version
Operating instruction
The handset comes already paired to work with the fire and the time set etc. Please read
these instructions carefully and watch the instructional YouTube video through your
internet web browser if necessary. Do not try pairing the handset thinking that it is not
paired it is more likely the handset is not being pressed correctly.
For safety reasons the handset is made not to be operated by accident, please follow the
instructions as below:-
•
The handset should be showing a Wi-Fi symbol
in the top right of the
display. This means the handset is within range of the fire Control. (If the
symbol is not there check a) the batteries are in the handset and the fire gas
control properly the correct way around, b) the batteries are good batteries
and c) that the small isolation switch on the gas control in the top left corner
is in the “ I “ position and not the “ O “ position).
•
To start the fire, with one hand grasp firmly around the rear of both sides of
the button area control. The green unlock light will illuminate. (Keep the
handset held to keep the control unlocked, i.e. the green light on, at all times
to enable operation of the buttons).
•
Then with the other hand touch and hold a finger on the power button for
about 3 seconds. (Upon touching a short beep and a flash of the unlock light
will happen).
•
As the handset beeps and flashes the green light for the second time, the
word “pilot” will appear at the bottom left of the display, immediately release
the power button as the word the word “pilot” appears. (It may take a few
practices to do this correctly, but as stated it is done in the interest of safety
to prevent unintended operation.)
•
The Fire should be lit within a few seconds. (N.B. If power button is held for
more than a few seconds after second flash/beep/word pilot appears, the
command is ignored for safety reasons. Similarly if it is released too soon
before the word pilot appears, the command is also ignored. With this
system, the control has been designed to ensure that only intended ignition of
the fire occurs.)To stop – with handset held to unlock it first, press then
release power button.
200759_2 Issue 3
20
Operating the Stove - Remote Control Version
3) Setting the time
Should you have to set the time or change the time you need to enter the SETUP menu.
Hold the handset to unlock the keypad and keep held throughout the following steps, (if
you release too soon the menu will exit and you will have to start again). Press and hold
set for several seconds. The symbol in the top centre will flash. Press and release the
“mode” button several times until the word “SETUP” appears flashing in the top right
corner of the display.
Press and release “set” again to enter the “SETUP” menu.
Here you can change the clock from 12 hr or 24 hour format, the day
of the week, hour of the day, minute of the day and the display in
Celsius or Fahrenheit.
To navigate through the menu “set” moves to the next parameter
and “Mode” moves back to the previous parameter. “+” and “-
“change the display parameter.
Setting the display for 12 or 24 Hour display
The H indicates that it is time to set the timer to either 24 hour display
or 12 Hour (AM or PM) display. Press the + or – button on the handset
to toggle between the two settings. When you are ready to confirm the
setting you want press the “SET” button to progress to setting the day
of the week.
Setting the day of the week
Press and release the + and – buttons until the correct day of the week
is shown on the display.
(Mo = Monday, Tu= Tuesday, We=Wednesday, Th=Thursday,
Fr=Friday, Sa= Saturday and Su=Sunday).
Press “SET” to accept the day of the week and to progress to setting
the Hour of the day.
Note: Whilst doing this setup pressing “SET” advances to the next
display and pressing “MODE” will return you to the previous display
setting.
Setting the Hour
Press and release the + or – button to change the hour to the correct
hour and press set to store and to move to setting the minute.
Repeat this for setting the minutes.
200759_2 Issue 3
21
Operating the Stove - Remote Control Version
Setting the temperature display to Celsius or Fahrenheit
Press and release the + or - button to toggle between C and F.
When the display shows the desired symbol, press and releases the
“SET” button to store.
As the important settings above have now been done, press and hold
for a few seconds the “SET” button for a few seconds and this will exit
the setup menu. The control is now ready for use with the Fire Control.
Paging the handset
If you have misplaced the handset you can page it by pressing the + button only on the
fire control for around 5 seconds. The handset will flash and make a noise to help you to
locate it. Once you pick up the TESC it knows you hold it and so the sound stops. The
flashing and sound will last for 60 seconds each time the handset is paged as described.
If not found in 60 seconds, page again and so on. NOTE: PRESS “+” Button ONLY, NOT
“+” and “-‘Together as you will accidentally break the handset pairing and have to reset
handset to factory state and pair again (see other parts of the booklet if this happens).
Note: the legend at the bottom shows the battery condition of both the batteries in the
hand set and in the fire control alternately. RC = Remote Control handset and FC = Fire
control. The control is designed to get the most out of the batteries but when eventually
the display shows they are spent(when the battery legend is an empty area, we
recommend you change the batteries in the handset before they are flat, to avoid having
to re-program the time of day in again. N.B. Pairing is not lost, even if the batteries are
removed or flat.
Advanced settings Menu
In the event that you may want to change the other pre-set settings of the control
features. Do not do a long press and hold above but a normal short press and release
will take you into the advanced settings area.
Advanced settings options are:-
•
Back light –
o A = Automatic (default setting). The back light comes on in the dark but
not in the light.
o 0 = Light never comes on.
o 1 = Light comes on whenever handset is unlocked.
•
Display contrast – 8 levels from 0 to 7 (default level 4).
•
P = pairing with other devices other than the fire control. The hand set can pair
with other modules to :-
L= Operate an electric light – which is the dimmable in 9 steps
o F= operate an electric fan –which can have 9 speed levels
o A= operate an auxiliary contact to operate another device.
200759_2 Issue 3
22
Operating the Stove - Remote Control Version
Other Modes than Manual mode
Depending upon the model of fire, your handset maybe enabled to have some automatic
features, namely, Thermostat mode, timed thermostat mode and snooze mode. Snooze
mode can be selected to work with in conjunction with either manual or thermostatic
modes.
You can switch between modes at any time with the handset unlocked by pressing and
releasing mode button to toggle between modes.
Note: If at any time the power button is pressed during operation, this will stop the fire
and exit any automatic mode and return the handset to manual (MAN) operation mode.
Pairing the Handset to the Fire Control and resetting the handset to accept new
pairing
NOTE: Do not do this operation just because of difficulties in understanding of operating
the handset. The control is supplied originally with the pairing done so should not need
doing on initial installation. Check understanding of control operation is understood.
If either the handset is reset or the gas control has the pairing operation buttons
operated, the pairing that existed will be broken and both the two operations below
will be required to be done to enable a new pairing to be set up.
Firstly Factory Reset of display handset (to enable handset to be paired
again)
•
To reset a handset to factory conditions and enable it to be paired
with a new control, hold the handset to unlock.
•
Press and hold the “set” button until handset beeps and release
the “set” button. The symbols at the top of the display will be
flashing.
•
Press and release the mode button as necessary until the word
SETUP is flashing in the top right corner.
•
Press and release the “set” button again to enter the “setup” menu.
•
Press and release the “set” button several times until CAO appears
on the display (CA means Cancel All).
•
Press and release the “+” button once to change the display to CA1. Press
and release the “set” button once more and the display will change to say the
word TESC as shown adjacent.
•
The handset is now free to pair again.
200759_2 Issue 3
23
Operating the Stove - Remote Control Version
Pairing Gas control with handset after handset has been made free to pair as
above operation:
•
Ensure all the batteries are fitted correctly and with the power isolator slide switch
on the TESC Fire control put in the “I” position).
•
Place the handset within 1 metre ( 3 feet) of the fire when pairing
Simultaneously press and hold the – and + buttons on the fire control (i.e. not the
handset) until the RED LED light on the gas control starts to illuminate.
Immediately as it does so, press the power button on the gas control and the
handset makes a noise and the display shows a symbol like a number 7 back to
back with a reverse number 7.
•
Then within a minute hold the handset to unlock the keypad a green unlock light
will illuminate when the handset has detected your hand. The green light must be
illuminated in this way for any of the command buttons to accept commands to
operate the fire control.
•
While the display is as described and holding the handset as described, press the
“SET” button with the other hand to accept the pairing request to finish off the
pairing of the handset to the Fire Control and to enter the setup the time of day
on the handset as described in previous sections.
N.B If the display returns to the one shown above with the word “TESC” shown, then too
much time has passed before pressing “SET” and so the handset has not paired yet.
Simply repeat pairing again. N.B Only ever press “+” and “-“buttons together when
pairing handsets. If done afterwards this will break the pairing made and a factory reset
of the handset will need to be performed See Factory Reset of display handset later on
in the instructions.
Snooze mode in manual operation
Snooze mode is a time period you can set which will turn off the fire after a certain time
period has elapsed.
The snooze time period can be set before or during manual operation of the fire. Hold
the handset to unlock as described previously and press the mode button as many times
as necessary until the word MAN and the Zzz symbols are flashing at the top of the
display. Press and release the set button and this will put the control into Manual snooze
mode.
The default time period for the snooze time period is 1:00 hour. Pressing the set button
again will show you the snooze time period remaining. This can be adjusted by pressing
the “+” or “-“buttons. The timer period that can be set is from 1 minute to 4:00 hours.
After adjusting the time, press set again to enter the time setting required (or if left for a
few seconds this time is now stored and used).
Once this countdown timer has reached zero the fire will turn off (as if you had pressed
off manually, it does not recycle).
200759_2 Issue 3
24
Operating the Stove - Remote Control Version
Snooze mode in Thermostatic mode
The same thing as above can be done before or during a thermostatic mode operation
(see below).
Thermostatic mode
The handset has within it a thermostat sensor and this can be set so the fire will heat the
room to match the temperature set in the handset. There are 3 temperature types that
can be set:-
-Day mode temperature that has a sun symbol on the display – the default
temperature is 24 C
- Night temperature that has a half moon symbol on the display- the default
temperature setting is 18 C
-Frost protection that has a snowflake symbol on the display – the default
temperature setting is 5 C
Hold the handset and press and release the mode button several times as necessary
until the display has a thermometer symbol flashing at the top of the display. Press the
set button to enter this mode. Press the set button again to see the temperature setting
that is set and the mode (the default is 24 C) and on the left of the display is a sun
symbol showing it’s the day temperature. If a different set temperature is required, while
the display is showing this set temperature, press the + and – buttons to alter the setting.
When finished either press set or leave and after a few seconds the new setting will be
accepted and the display will return to the time of day screen.
On the anniversary of the net minute of the clock, the set temperature will be compared
to the actual temperature displayed on the handset (i.e. the room ambient temperature
around the handset).
Note- when the set temperature is reached while the fire is in operation, the fire reduces
the burner power level each minute until the burner is reduced to the minimum setting.
Once the temperature in the room drops below the set temperature the burner power
level will increase each minute until the burner is increased to the maximum setting.
Note: If at any time the power button is operated during Thermostat mode, the control
will cancel any thermostat operation and return the control to manual mode.
200759_2 Issue 3
25
Operating the Stove - Remote Control Version
Paging the handset
If you have misplaced the handset you can page it by pressing the + button only on the
fire control for around 5 seconds. The handset will flash and make a noise to help you to
locate it. Once you pick up the TESC it knows you hold it and so the sound stops. The
flashing and sound will last for 60 seconds each time the handset is paged as described.
If not found in 60 seconds, page again and so on. NOTE: PRESS “+” Button ONLY, NOT
“+” and “-‘Together as you will accidentally break the handset pairing and have to reset
handset to factory state and pair again (see other parts of the booklet if this happens).
Installer note:
To reset the handset to factory conditions (to enable the handset to be paired
with another fire for example), hold handset to unlock, press and hold for at least
10 second the SET button. The green and red lights will start to flash. They will
flash for 1 minute and during this minute if you want to reset the handset, open
the battery box and remove a battery for a few seconds. Replace the battery and
cover, the handset will now be reset and ready to pair as a new handset to
another (or the same) device as shown above in pairing section.
Pairing a new handset
Remove the back panel and insert two AA Alkaline batteries in the direction
shown by the symbols moulded into the compartment and replace the cover.
Hold the handset with one hand ensuring your hand is wrapped around the back
and that your hand is in contact with both sides of the handset. The green light of
the “Unlock” symbol should light and flash. The flashing indicates that it is not
paired with anything at the moment and is ready to be paired. Put the handset
down within 1 metre of the Fire that you wish to pair the handset with. Press the +
and – buttons on the Fire Control (i.e. not the +and – buttons on this handset) for
around 6 seconds. The red light on the gas control will flash and then within 2
seconds press the power button on the fire control the handset should make a
noise and the green “Unlock” light should be flashing even without holding the
handset. The handset has received a pairing request and to accept this pick up
the handset and hold as described above to keep the keypad unlocked and press
and hold the “SET” button for 3 seconds. You will hear a beep and now the
handset is paired to the fire control. The unlock green light will stay permanently
lit when holding the handset Note: If the power button differently to the above i.e.
pressed for too long or too short a time or the grip on the handset is not firm or
released too soon, the Ignition will be interrupted and not complete. The reason
for the remote control having this strict start sequence is for safety reason so that
the starting operation of the fire will be most unlikely to be done other than
intentionally by an adult. If not done correctly, wait a few seconds and try again.
PLEASE EXPLAIN TO THE CUSTOMER THESE LIGHTING AND EXTINGUSIHING
PROCEDURES
200759_2 Issue 3
26
Maintaining the Stove
Important Note:
Should the glass door become broken or damaged in any way, turn your stove off and
do not attempt to re-light it. Contact your dealer for a replacement to be fitted before
relighting the appliance. The glass used in this appliance is a ceramic type glass suitable
for operation up to 750 degrees do not use any other types of glass in this appliance.
Cleaning
We recommend only doing this when the stove is cold using a soft brush to clean any of
the stove surfaces, this is normally sufficient to remove dust and general debris. For
stubborn marks you can use a damp lint free cloth, ensure that all surfaces are dried off
immediately. We do not recommend using any kind of chemicals or abrasive
materials. It is possible to touch up the paint using the original black stove
paint, however this new paint will then need to cure.
Curing the paint
It is important to note that upon initial lighting of the stove you will notice a strong odour,
this is the paint curing and is completely normal.
Most high temperature paints operate in the same way. They use a resin which dries at
room temperature and a silicon resin which cures at high temperatures. When the stove
is burned the dry resin burns away and the silicon cures. This transition occurs about
240 degrees C / 475 degrees F.
Curing times will vary but leaving the fire on the high setting for at least four hours (and
then repeating this three times) is usually sufficient to cure the working surfaces of the
stove. The house needs to be fully ventilated during these initial burnings and although
the smoke is mostly Carbon Dioxide there are other components of the smoke which
make it smell bad and may irritate some people. These problems will go away after the
first few burns depending of the duration and surface temperature of each burn. The
hotter the stoves gets the more it will cure.
IT IS NORMAL FOR THE STOVE TO GIVE OFF ODOURS WHILST THE PAINT,
SEALANT AND CAST IRON MATURE.
Red
indi
cati
on
light
Pre
ss
to
incr
eas
e
flam
e
Pre
ss
to
dec
rea
se
flam
e
Pre
ss
pow
er
butt
on
and
hold
for
a
200759_2 Issue 3
27
Trouble-shooting
The gas pilot will not ignite or stay lit
•
Ensure the gas is turned on at the appliance and the meter / cylinder.
•
Check for blockages (especially after the pressure test point connection).
•
Is there a strong spark being generated, If not firstly check that the spade connection
is push fully into the pilot assembly. Also check that the batteriy pack located inside
the lower left side casting. If still issues check that the spark generator has not been
bent in transit – if it has, bend the metal generator so the spark is hitting above the
pilots gas outlet not below. The spark generator should be ideally10mm from the pilot
head
•
The pilot gas slider must be pulled completely out for at least 20 seconds once the
pilot is established to ensure the safety thermocouple is heated sufficiently.
•
Ensure that both spades of the TTB connection are firmly connected and not
damaged.
•
Ensure the thermocouple connection into the gas valve is tight.
•
Ensure that the pilot head, injector and burner ports are not obstructed or blocked
and are free from any dust or dirt.
•
Ensure gas pressures and flow rates are correct, as this will prevent ignition of the
pilot. An indication of high pressure can be a whistling sound from the pilot.
•
The pilot flame should burn with a strong blue flame. The flame should be focused
on the tip of the thermocouple.
The main burner does not seem to burn correctly or will not stay alight
•
Check the flue draft. In adverse conditions and when the flue is extremely cold it is
possible the products of combustion may build up inside the stove and not exit via
the flue ways correctly, in this scenario the ODS will activate and turn off the burner.
If this occurs try to light the burner again, this could take several attempts in order to
get sufficient heat / draw in the flue so the products of combustion can leave the
stove correctly
•
Ensure gas pressures and flow rates are correct.
•
Confirm that the flame pattern is even across the surface of the burner by removing
all of the ceramics. Only do this once pressures and flow rates are confirmed as
being correct.
•
Double check all ceramics are re-positioned correctly.
Once all the above checks are completed, leave the appliance in a fully commissioned
state.
200759_2 Issue 3
28
Servicing Instructions
Servicing should be carried out annually by a qualified installation gas safe engineer.
•
To open the door, remove the screw from above the handle to allow the door to open
(Long allen key supplied).
•
Remove the logs and clean any dust and debris from the top of the burner unit and
the inside of the stove. A vacuum cleaner can be used, but take care around the pilot
assembly to prevent accidental damage. A clean soft brush can also be used. Take
care not to brush any debris towards the pilot as this may cause an obstruction in the
jet.
•
Clean any dust/debris from each individual ceramic using a very soft brush.
•
Check the condition of the ceramics. Damaged ceramics will affect the efficient
operation of the stove and will need to be replaced.
•
Clean the glass with a soft cloth.
•
Ensure the glass clips are tightened (finger tight is normally sufficient)
•
The outside of the stove can be cleaned as per instructions given previously.
•
Re-lay the ceramics and close the door ensuring an air tight seal.
•
Ignite the appliance and observe an even flame pattern.
Carry out all necessary final checks and leave the appliance in a fully commissioned
state.
200759_2 Issue 3
29
Commissioning Form
THIS SECTION MUST BE COMPLETED AND SIGNED BY THE INSTALLATION
ENGINEER
PLEASE LEAVE WITH THE CUSTOMER AND THE APPLIANCE.
Size of Governor setting: ___________
Length and size of gas supply: __________
Meter pressure Fire only on: ________________
Meter pressure with all other appliances on: __________________
Burner pressure Fire only on: _______________
Burner pressure with all other appliances on: __________________
Gas rate - Natural Gas - Time for 1 cubic foot in seconds: ___________
Top or Rear Flue Installation: _________
Overall length of flue: __________
Is there any spillage: __________Is the draught excessive: __________
Is there any permanent ventilation in the room: ____________________
Is the TTB connected correctly (both ends): ______________
Is the aeration of the pilot correct: __________
Does the flame encircle the FFD: ___________
Does the remote control provide full functionality: _____________________
Installation Engineers Name:
_____________________________________________________
Installers
__________________________________
Address
__________________________________
__________________________________
__________________________________
Post Code: ______________________________________
Telephone: __________________
Fax:_________________Mobile:___________________Other:
Gas Safe Registration No:
_______________________________________________________
Signed: ___________________________________ Date: _________________
200759_2 Issue 3
30
Guarantee
Your decorative gas fire, when installed in accordance with the installation instructions
and operated in accordance with these instructions should provide many years of safe
and efficient operation.
We thank you for purchasing our product and trust it will provide excellent service.
This appliance carries a manufacturer’s guarantee of One (1) Year.
The guarantee begins at the date of purchase. However should the appliance remain un-
installed the guarantee period will commence six (6) months after the original purchase
date.
Please note consumable items including the ceramic logs, Mica board and rope seals
are not covered by this guarantee. The glass on the appliance is also not covered by any
form of guarantee.
We agree to repair free of charge or, at our option, replace the appliance or part thereof,
which may prove to be defective within the guarantee period.
The guarantee is void if:
•
The appliance is not installed and operated in accordance with our instructions, or
•
Repairs or modifications have been carried out by the purchaser or any third party
not authorised by us or:
•
The appliance has been misused or accidentally damaged, or
•
Damage is due to ‘fair wear and tear.’ or
•
The appliance or defective component(s) are not returned to us, prepaid postage.
•
The appliance has not been serviced annually by a ‘Gas Safe Registered’ engineer.
The rights given in this guarantee are limited to the UK mainland and are in addition to
any to which you may have a statutory entitlement.
Please retain your purchase receipt. We will need to see this in the event of a claim
under warranty.
Broseley Fires LTD
19-34 Bedesway,
Bede Industrial Estate,
Jarrow,
Tyne and Wear,
NE32 3BE.
Tel: (0191) 430 0901
Fax: (0191) 430 9522
http://www.broseleyfires.com
200759_2 Issue 3
32
Important Note:
The energy efficiency class of this product is defined using a seasonal efficiency calculation
which reduces the actual net efficiency of the product where the use of automated heat control,
thermostats, window open sensors and timers are not used. This is not to be confused with the
net efficiency, or useful efficiency of the appliance (shown in the tables above).
This product MUST be installed by a Gas Safe Registered Installer. Full details are provided
in this manual.
Broseley Fires Ltd, 19-34 Bedesway, Bede Industrial Estate, Jarrow, Tyne and Wear,
NE32 3BE.
Product Fiche
Manufacturer : Broseley Fires Ltd
Model No.
EVO 5 Remote
Top Flue
EVO 5 Remote
Rear Flue
EVO 5 Slide
Top Flue
EVO 5 Slide
Rear Flue
Fuel Type
Natural Gas I2H
Natural Gas I2H
Natural Gas
I2H
Natural Gas
I2H
Energy Efficiency Class
C
D
D
E
Indirect Heating Functionality
No
No
No
No
Direct Heat Output kW
4.3kW
4.15kW
4.3kW
4.15kW
Indirect Heat Output kW
N/A
N/A
N/A
N/A
EEI
79%
76%
74%
71%
Useful Energy Efficiency (NCV)
High : 83%
High : 80%
High : 83%
High : 80%
Useful Energy Efficiency (NCV)
Low : N / A
Low : N / A
Low : N / A
Low : N / A
Nominal Heat Output
High : 4.3kW
High : 4.15kW
High : 4.3kW High : 4.15kW
Nominal Heat Output
Low : 2.7kW
Low : 2.6kW
Low : 2.7kW Low : 2.6kW
Heat Output Temperature
Control
Electronic Room
Temperature
Control Plus day
Timer
Electronic Room
Temperature
Control Plus day
Timer
Two Manual
Stages
Two Manual
Stages
Permanent Pilot Power (kW)
N/A
N/A
N/A
N/A
Space Heating Emissions NOx
(GCV)
130mg/kWh
130mg/kWh
130mg/kWh