Ametek TR-2000 Operation Manual
File Specifications
| Brand: | Ametek |
| Category: | Measuring Instruments |
| Model: | TR-2000 (Operation Manual), prNyOB4kDvwqk |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 105 pages |
Download PDF
Download Ametek TR-2000 Manual (105 pages)Read Online:
Read the Ametek TR-2000 Operation Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
TR-2100 User Manual
35 TR-2100 Connection To make a connection, click on the Connect button. The program will attempt a connection by looking for a CLI command prompt. If this is successful, it will attempt to read the EEPROM chip on the first board of the system. Once the values have been read from the board, the actual input values will start to be displayed. There are two main parts to the calibration process - offset and gain. Offset Adjustment The offset should ALWAYS be adjusted first because it will affect the subsequent accuracy of the gain offset. To set the offset, it is important th ...
TR-2100 User Manual
49 Digital-only Input Board Jumper Locations Set the Digital-only Input Board configuration jumpers per Table 15. Refer to Error! Reference source not found. for the location of each configuration jumper. Table 15 Board No. Extra Digital Channels DIG BRD SEL 0 DIG BRD SEL 1 1 1-32* On On 2 33-64* Off On 3 64-96* On Off 4 97-128* Off Off * Channel number as reported in Display Station will depend on the number of analogue boards fitted. Figure 13 Digital-only Input Board Jumpers ...
TR-2100 User Manual
76 Power (fundamental) Apparent f f S V fI = * Real f f f P V I Cos = * * Φ Reactive f f f Q V I Sin = * * Φ For delta VTs real power is computed using the two wattmeter method. Displacement power factor PF Cos = Φ Impedance (fundamental) I V Z f f f = Imbalance mI V V = − + 1 1 100 * % (Ratio of NPS to PPS) Phasor Measurement The TR-2100 acquisition system is organized so that a sample is taken at the second marker. The computed absolute phase angle from a Discrete Fourier Transform (DFT), using a 1 cycle window starting with this sample, will yield the angle of the v ...
TR-2100 User Manual
54 PC conflict, or a failed port. Please call Technical Support for additional information or help. 14. Now you will perform the following command to format the Hard drive. At the CLI> prompt, type in system formatdisk and press the Enter key. Formatting will take 30 minutes or longer to complete. See the example below. Once the process is complete, a message will appear telling you that the format was successful. Example: CLI>system formatdisk 15. At the CLI> prompt type in the word QUIT and press the enter key. The recorder will respond that it has disconnected. Exi ...
TR-2100 User Manual
51 Format Procedure 1. Verify that all events at the TR have been retrieved. If not, retrieve them before proceeding. This includes Harmonic Logs, Trend Logs, and the standard TR events. 2. Attach one end of the TR-2100 direct connect cable (AMETEK P/N 1077- 271) to the computer’s unused RS-232 port and the other end to the TR- 2100’s Local RS-232 port (found on the front panel). 3. Turn on the computer and start Win95. 4. Open Comms Manager from the System menu, and note the port and port baud rate settings. 5. Exit the DS program now (close the program). Do not just ...
TR-2100 User Manual
16 Duplicates the function of the front panel LED. Printer If a printer is connected to the TR-2100, it will report three separate events: • All entries to the event log • The system status will be printed with a test record when the Test button is pressed. • A full data record with channel configuration, profile and graphical display of analogue and digital waveforms is printed when the recorder is triggered. To enable the printer, see Chapter 4. To select the printer type, see the Display Station manual. Printout Format The TR-2100 logo is printed at the top, and th ...
TR-2100 User Manual
46 Hardware Settings Acquisition Board Configuration Switches Set-up the acquisition board configuration switches as shown below. Reference the System Drawings for number of channels and options to be enabled. Bank 1 Table 7 Table 8 * Default setting Switch Function Off On 1 Digital-only cards Yes No 2 System frequency 50 Hz 60 Hz 3 No. of analogue cards – 1 4 No. of analogue cards – 2 See 8 5 Cross triggering Disable Enable 6 GPS receiver Yes No 7 Time code port Master Slave 8 (undefined) Switch 3 Switch 4 Analogue Input Boards Off Off 1 Off On 2 On Off 3 On On 4 Bank ...
Ametek TR-2000 user guide recommended for: 502-3000 Series, iPac, Solartron Metrology ORBIT LT, Reichert r2i300, Tono-Pen XL.
⚠️ Download Safety
The Measuring Instruments Operation manual (105 pages) is completely safe to download (last scan date: 26/03/2026).
Related PDF Instructions for Ametek TR-2000:
-
Ametek ta3000R Monitor Operation & user’s manual
ta3000R46 -
Ametek Land FTI-Eb Thermal cameras Installation manual
Land FTI-Eb28 -
Ametek DMS-3K Measuring Instruments Installation & operation manual
DMS-3K206 -
Ametek VERSITRON BT130S Test Equipment Operation manual
VERSITRON BT130S82 -
Ametek 5000 Inverter Quick start manual and safety instructions
500027 -
Ametek Chandler Engineering 8040D10 Measuring Instruments Instruction manual
Chandler Engineering 8040D1052
Measuring Instruments Equipment: Frequently Requested
-
Vega VEGAVIB 63 Switch
16.02.2026Quick reference guide for the Vega VEGAVIB 63 Switch. It provides information on safety and installation steps, device reset instructions, software updates, application scenarios.VEGAVIB 63, 36 -
York Survey Supply 263090 Measuring Instruments
13.01.2026Full user manual for the York Survey Supply 263090 Measuring Instruments. The manual describes menu navigation, system parameters, software installation.263090, 2 -
TESTO 605-H2 Measuring Instruments
10.01.2026Device instruction guide for the TESTO 605-H2 Measuring Instruments. The manual describes usage examples, configuration options, safety protocols, performance optimization.605-H2, 2 -
Zircon MultiScanner HD800 OneStep Measuring Instruments
21.01.2026User reference manual for the Zircon MultiScanner HD800 OneStep Measuring Instruments. This documentation covers troubleshooting tips, diagnostic information, setup guidelines.MultiScanner HD800 OneStep, 2 -
Bside ADM02 Multimeter
26.12.2025Product usage guide for the Bside ADM02 Multimeter. This documentation details technical guidelines, performance optimization, warranty information.ADM02, 16 -
BEKA BA538C Monitor
16.12.2025User reference guide for the BEKA BA538C Monitor. It provides technical information on backup procedures, software updates, operational procedures, device calibration.BA538C, 26
Have some Questions about Ametek TR-2000 Device?
Get valuable and actionable advices from other Ametek TR-2000 device users. Describe your problem or question, regarding the using of TR-2000, in as much detail as possible, and other users will be able to answer you.