Text of the manual
How to access Web Management and
change HDCP setting to Auto?
For BenQ:
WDC10 (InstaShow)
Applicable for All Regions
Version: 01
Date: 2016/10/13
How to access Web Management?
Equipment:
o Laptop or PC.
o Network cable (RJ45).
o Target units, InstaShow Hosts and Buttons.
Follow below steps:
1. Connect InstaShow Host (RX) directly to laptop using network cable (RJ45).
2. Connect power source to InstaShow Host (RX) using a USB A to micro USB B cable.
3. Wait until the LED indicator on your InstaShow Host lights up static green.
4. Turn off the Wi-Fi of your laptop or PC.
5. Change laptop's IP address to 192.168.20.X (e.g. 192.168.20.100).
6. Execute the browser in laptop or PC, using below link to access Web Management.
http://192.168.20.1
7. Enter the default user name (admin) and password (0000) to log in.
8. You can do the FW / Driver upgrade in Web Management.
Please follow the installation guide to do upgrade FW / Driver of Host and Buttons.
How to change HDCP setting to HDCP auto?
1. Access Web Management.
http://192.168.20.1
2. Access Factory Menu by below link on browser.
http://192.168.20.1/whe_hidden_rx.htm
2. Change the "HDCP Auto" function to On
3. Then press Apply to save the setting.