C.A. Technologies CPR Product Information

Specifications

Brand: C.A. Technologies
Category: Paint Sprayer
Model: CPR (Product Information)
File Type: PDF
File Size: —
Pages: 5

Read Online

Read the C.A. Technologies CPR Product Information online using the built-in PDF viewer.

Text of the manual

HVLP/PRESSURE REDUCED AIR CAP AND FLUID NOZZLE CHART

MODEL NO. AIR CAPS FLUID TIP RANGE *MAX GUN INLET PRESS. FOR HVLP FAN CONTROL SCFM @ MAX GUN INLET STANDARD IN CAT PACK AVAILABLE FLUID NOZZLES TIPS NEEDLES / marking on needle Included 33-0208 0.8mm (.022") 40-1308 (308) 33-0210 1.0mm (.040") 40-1310 (310) 33-0212 1.2mm (.046") 40-1312 (312) Included 33-0213 1.3mm (.052") 40-1313 (313) 33-0214 1.4mm (.055") 40-1314 (314) 33-0215 1.5mm (.059") 40-1315 (315) Included 33-0217 1.7mm (.070") 40-1317 (317) 33-0219 1.9mm (.075") 40-1319 (319) 33-0222 2.2mm (.086") 40-1322 (322) Actual fluid nozzle and air cap combinations are determined by application (see application chart page 4) *Note: Air cap test gages are available to confirm HVLP compliance. *Gun inlet pressures may vary as required by application CPR 60-1504 (S) 23-2101 CPR (Pressure Reduced) 23-1301 (HVLP) 0.8 - 1.7 0.8 - 2.2 29* 29* 11 13.5 CPR PRESSURE FEED SPRAY GUN PRODUCT INFORMATION Coating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: 888.820.4498, Fax: 303.438.5708 www.spraycat.com The CPR gun comes equipped with both a pressure reduced air cap 23-2101 and a HVLP air cap 23-1301 for areas requiring HVLP compliance. 23-2101 - consumes 11 cfm at 29 psi gun inlet. 23-1301 - consumes 13.5 cfm at 29 psi gun inlet. 23-2101 pressure reduced air caps can be used with the 0.8 mm - 1.7 mm fluid orifices listed below. 23-1301 HVLP air caps can be used with the full range of fluid orifices listed below. DISTRIBUTED BY: Pro Wood Finishes 14622 Southlawn Lane Rockville MD 20850 Ph: (301) 424-3033

Operation and Maintenance Instructions for CPR Spray Guns

Operation 1. Connect air supply hose at handle of gun. 2. Connect a pressurized fluid supply to the gun fluid inlet. 3. Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel. It is best to control fluid flow by proper selection of fluid orifice size and use the fluid control knob to “fine tune flow rate”. 4. Fan width can be adjusted using the fan control knob. Turning the knob clockwise narrows the fan. Maintenance IMPORTANT! Routine cleaning and maintenance is essential to insure proper gun operation. Several states prohibit spraying solvent into the atmosphere and require the use of covered gun cleaner. 1. If a gun cleaner is being used, connect and clean the gun in the gun cleaner according to the manufactures instructions. 2. If a gun cleaner is not being used: Remove air cap and clean separately using clean solvent. For pressure setups, connect a pressurized solvent supply to the fluid inlet, trigger the gun allowing solvent to flow thru the gun until clean. NOTE: Gun head disassembly is not recommended for normal cleaning and maintenance. Gun head disassembly and reassembly instructions: Have repair kit # 10-106 available before gun disassembly. Gun head disassembly To remove the nozzle carrier (4) and air cap adapter (6): 1. Remove the air cap (1), fluid nozzle tip (2), fluid nozzle body (3), and needle (13). 2. Remove the needle seal cartridge (23). 3. Loosen the locknut (9) and remove fluid inlet (10) using a 5/8” open-end wrench. 4. The nozzle carrier (4) and air cap adapter (6) will now slide forward from the gun body (11). Gun head reassembly 1. Install a new o-ring (5 and 7) on the air cap adapter (6). 2. Install the thread locknut (9) onto the fluid inlet (10) as far as possible. 3. Install a new fluid inlet seal (8) into the recess area on the nozzle carrier (4) inlet port. 4. Slide the nozzle carrier (4) into air cap adapter (6) and insert into the gun body (11) as far as possible. Be sure the nozzle carrier (4) extends into the hole at the back of the gun head. Install the needle seal (23) but do not tighten. 5. Rotate the nozzle carrier (4) until the fluid inlet port in the nozzle carrier (4) is aligned with the threaded hole in the body. While in this position, insert the fluid inlet (10) and tighten firmly. 6. Tighten the needle seal (23) to approx. 12 ft.-lb. torque. 7. Tighten the fluid inlet (10) to approx. 25 ft.-lb. torque. 8. Tighten the locknut (9) to approx. 33 ft.-lb. torque.

HVLP AIR CAP TEST GAGES

FOR CPR GUNS ITEM NO. PART NO. DESCRIPTION ITEM NO. PART NO. DESCRIPTION 1 See Air Cap Chart Air Cap** 16 60-204 Needle Return Spring* 2 See Air Cap Chart Fluid Nozzle Tip** 17 60-201 Rear Bushing 3 33-1202 Fluid Nozzle Body 18 60-119 Seal* 4 60-L31H Nozzle Carrier 19 60-1520 Air Valve Assembly 5 98-8026 O-Ring* 20 60-302 Air Valve Poppet 6 60-34H Air Cap Adapter 21 60-125 O-Ring* 7 60-131 O-Ring* 22 61-1003 Air Valve Spring* 8 60-124 Fluid Inlet Seal* 23 60-1400 Needle Seal Cartridge* 9 60-128 Locknut 24 60-2101 Trigger 10 60-126 Fluid Inlet Fitting 25 60-1510 Air Control 11 60-1120-CPR CPR Gun Body HVLP 25A 60-122 Plug (optional) 12 See Air Cap Chart Fan Control Assembly** 26 60-104 Air Inlet Fitting 13 See Air Cap Chart Fluid Needle** 27 60-1033 Trigger Pivot Set 14 60-202 Fluid Control Knob 28 98-0109 Allen Plug 15 60-205 Spring Seat* **See air cap selection chart on page 1 *Indicates part included in repair kit # 10-106

CPR Smart Pack Includes:

98-0104 3/8” Socket 98-0112 Ratchet Wrench 60-8001 Gun Wrench 98-0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1 CPR-303R2 Includes: 51-303 1 QT Aluminum Pressure Cup 52-5R2 Pressure Cup Regulator 98-0104 3/8” Socket 98-0112 Ratchet Wrench 60-8001 Gun Wrench 98-0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1 CPR-PPSR2 Includes: 91-460 950 mL 3M™ PPS™ Pressure Cup 91-462 Lids and Liners (Available in 25 Pack) 91-475 #18 PPS Adapter 52-5R2 Pressure Cup Regulator 98-0104 3/8” Socket 98-0112 Ratchet Wrench 60-8001 Gun Wrench 98-0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1 CPR HVLP/PRESSURE REDUCED SPRAY GUN MATERIAL TYPE FLUID ORIFICE x AIR CAP MAXIMUM PATTERN WIDTH CFM Very Thin less than 16 sec. Zahn #2 inks , dyes, solvents, stains Thin 16 to 20 sec. Zahn #2 lacquers, enamels, primers, sealers Medium 21 to 30 sec. Zahn #2 automotive base coat enamels, primers epoxies, urethanes automotive clear coat Heavy over 30 sec. Zahn #2 heavy body primers high solid enamels high solid automotive coatings adhesives 23-2101 11 CFM 23-1301 13.5 CFM 1.3 mm x 2101 or 1301 1.4 mm x 2101 or 1301 1.5 mm x 2101 or 1301 1.7 mm x 2101 or 1301 23-2101 13" 23-1301 12" 23-2101 11 CFM 23-1301 13.5 CFM 1.7 mm x 2101 or 1301 1.9 mm x 1301 2.2 mm x 1301 23-2101 13" 23-1301 12" 23-2101 11 CFM 23-1301 13.5 CFM FLUID NOZZLE / AIR CAP SELECTION CHARTS CPR Series - Pressure Feed Guns 0.8 mm x 2101 or 1301 1.0 mm x 2101 or 1301 23-2101 13" 23-1301 12" 23-2101 11 CFM 23-1301 13.5 CFM 1.2 mm x 2101 or 1301 1.3 mm x 2101 or 1301 23-2101 13" 23-1301 12" Revised 11/17/15

Check Valve Assembly With Tubing

7 51-141 Safety Pop Off 8 52-5R2 Full Regulator Assembly 9 51-505-2 Barb Fitting 10 53-550 1/4" Swivel Fitting 11 52-50 15# Gauge Coating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: 888.820.4498, Fax: 303.438.5708 www.spraycat.com Items 6 through 11 included with 51-303-R2 PRESSURE CUP (R2 INCLUDES REGULATOR) PART SHEET PRODUCT INFORMATION 51-303 51-303-R2

Other Paint Sprayer Manuals