Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.1/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
CPS-EX2000 2000W Power Supply scalable
19“ embedded 2U/3U or hardmount in all positions, PFC 0,99
Features:
• 3D Heat Dissipation
• Real time I/V programming
• Real time I/V-monitoring
• Reference voltage f. autonomous programming
• CSB Current Share Bus
• Inhibit for safe interlocking
• Remote Shutdown
• Sense mode
• Power Good Relay DC-ok
• Precise dynamics on load change
• Series & parallel operation up to 100kW
• EMC conducted class B, radiated class A
• Efficiency 92-94%
• PFC Powerfactor 0,99
• Variable controlled fans from Papst
• Long lifetime under hard operation
• Solid 2U and 3U subframes available
Model
Voltage programmable
Current programmable
CPS-EX2000.024
24 – 30Vdc
42 – 84A
CPS-EX2000.036
30 – 45Vdc
28 – 56A
CPS-EX2000.048
45 – 58Vdc
21 – 42A
CPS-EX2000.072
58 – 90Vdc
14 – 28A
CPS-EX2000.110
90 – 150Vdc
9,1 – 18,2A
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.2/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Technical description - a unique mechanical concept
The Camtec CPS-EX models are high-precision industrial power supplies „Made in Germany“. These
power supplies are designed for scalable power systems.
For more than 25 years the Camtec Power Supplies manufactures high-end switch mode power supplies in
Germany. A field breakdown of below 0,004% over a 10-year period under review approves our ambitious
quality concept. Each manufactured Camtec product passes several 100% random tests for each detailed
function and a full-load Burn-In test.
Although it is not required from the safety norms our production applies a routine safety test to each
manufactured device, even if it is an extra low-voltage model. The components in the assembled device pass
stress aging to achieve an even level and to prevent from delayed failures. Our internal product engineering
guidelines provide a clear target: Camtec product reputation must say „mount and forget“. Quality is never a
mere promise for our team.
The CPS-EX power supplies provide low noise and ripple, a very quick programming, and a precise setting at
high load changes. With an efficiency of 92-94% and a power factor of 0.99, the devices are highly energy
efficient.
Equipped with high-end capacitors of outstanding lifetime our power supplies guarantee a very long and
reliable operation time. The circuit design of the CPS-EX Series allows cope playing with complex loads. The
internal protection circuits protect the power supply and the connected system, even in exceptional situations.
The CPS-EX series is protected from high transients by strong filters with high energy efficiency. All inputs and
outputs and the interface are electrically isolated. The design specifications call for the highest standards of
safety and interference suppression. The device was developed in accordance with the requirements of
EN61010-1, EN61010-2-201, EN62368-1 and the EMC standards EN55032 conducted Class B, radiated
Class A.
The mechanical design of the CPS-EX2000 device series is unique. It is the first power supply line in
the world market, which can be flexibly adapted to any installation situation.
The forced air-cooling system with monitored and load-dependent variable fan control, allows a detached
position in the system. By simple and cost-effective wall brackets the device can be integrated in any position
in 90° increments. Unlike comparable power supplies Camtec comes here for the first time to let the system
integrator completely free hand. The cooling concepts for supply and exhaust air can be designed to
completely remove the heat dissipation from the cabinet. Complex and expensive air-conditionings for switch
cabinets can be reduced to a minimum or even eliminate. Brackets for air channels are available as an option.
In selecting the fan, as with all our power supplies, in our opinion we use with the German manufacturer EBM
Papst the highest quality and most reliable devices in the world market.
The installation of the power supply in a 19" subrack is guaranteed in the simplest way. Again, our engineers
have decided to offer a completely open and flexible system. The optional front panels allow the power
supplies the use in either a 2U or 3U subrack. In this way we can realized 6kW in 2U-rack and up to 10kW in a
3U-rack with the CPS-EX2000 models. With Zero-Stacking the series allows scalable high-power DC source in
a comparable small 19-inch rack unit. For power applications with high dynamic range above 10kW we
recommend contacting our support team.
As accessories for the CPS-EX Camtec provides matched 19 "subframes. Our subracks deserve the name of
a carrier, because they really are extremely stable made of stainless steel. The power supplies have nickel-
plated steel pins to position the power supplies in the subframes. The so married together systems withstand
the toughest conditions. All mechanical connections in the power supplies or on the racks are constructed with
A2 or nickel-plated screws, so that they provide maximum protection against corrosion and conductivity.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.3/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Features
Idling behavior
The CPS-EX Series is permanently open-circuit proof. When an output
voltage is preset it comes stable. If a load is switched suddenly, the unit
stabilized within <1ms. An overshoot of the output voltage is irrelevant.
Start behavior
The power supply has a start delay of 1s to stabilize all measuring circuits
for the interface messages accurately. The power supply starts with a
ramp (soft start) of 100ms. The output voltage does not overshoot -
regardless of whether a load is connected or not.
Galvanic isolation and insulation
The switching power supply is galvanically isolated between the input and
the output. All major digital inputs and outputs of the interface are
electrically isolated.
V programming (Ureg)
The output voltage of the CPS-EX power supply can be adjusted by a
control signal. The setting is linear to the input signal. The power supply
operates data stable even at all output voltages.
C programming (Ireg)
The output current of the CPS-EX power supply can be adjusted by a
control signal. The setting is linear to the input signal. The power supply
operates data stable even at all output currents.
V Monitor (Umon)
The power supply provides real-time monitoring of the output voltage. It is
the exact and real value at the output terminals. If the sense line is used,
the real value is measured directly at the load. The latency signal preset to
the measured value is negligible since the control circuit is constructed
completely analogously.
C Monitor (Imon)
The power supply provides real-time monitoring of the output current. It is
the exact and real value at the output terminals. The latency signal preset
to the measured value is negligible since the control circuit is constructed
completely analogously.
Constant Voltage or Constant Current Mode (CV/CC)
The device can be operated as a DC voltage source or a constant current
source. The operating mode is signaled on the interface.
Auxiliary Voltage (AUX)
The devices feature a 12V / 500mA auxiliary voltage to operate external
peripheral.
Potentiometer Internal Control (Uadj/Iadj)
If the power supply shall only set with the built-in internal potentiometers,
the use of the internal reference voltage is possible. The power supply
requires no external signals and can operate completely autonomously.
Potentiometer External Control (Uadj/Iadj)
If the power supply shall only set with external potentiometers, the use of
the internal reference voltage is possible. The power supply requires no
external signals and can operate completely autonomously.
Sense Mode
The power supply has a sense mode to compensate for voltage drops of
2V per load line.
Fuse Mode
The unit can be operated in fuse mode. In the fuse mode, the unit is turned
off and locked when it was more than 5 seconds in constant current mode
to protect a connected defect load. The lock can be controlled remotely or
repeal by disconnection from the mains again.
Continuous Mode
The unit can be operated in continuous mode. In the continuous mode, the
power supply provides constant current mode in a continuous flow and no
ticker-operation.
Master-Slave Mode (Ureg-OUT/Ireg-OUT)
The master-slave mode can be defined in the parallel operation. One device can
be set as the master, the other involved network units act as a slave and the
setting signals follow current / voltage, which are commanded by the Master. This
ensures that all devices are operated synchronously.
Current Share Bus (CS)
In parallel operation, the involved network components communicate with each
other and share the total power evenly to each other.
Remote Shutdown (SD)
All CPS-EX devices have a remote shutdown (open collector or switching
contacts).
Inhibit Mode (Interlock)
The inhibit circuit reliably prevents unintentional starting of the power supply. The
control loop is internally locked. Since this blocking is done progressively it is
active even when the control signal, is missing due to a cable break or temporarily
suspend. A premature restart of the power supply is prevented.
The inhibit input can be connected to a relay or switch. If the contact is interrupted,
the power supply is switched off. If the contact is closed again, the power supply
restarts.
DC and AC Fail
By DC-fail the power supply reports that the power output is disabled.
By AC-fail the power supply reports an AC undervoltage. Both signals have
separate outputs. Each of them can be selected between NO and NC.
Over Voltage Protection (OVP)
On the interface is a message signal. Until the abolition of the fault the device
switches off.
Over Current Protection (OCP)
On the interface is a message signal. Until the abolition of the fault the device
switches off.
Temperature Control (TEMP)
The operating temperature of the power supply can be monitored via a signal
applied to the interface output.
Temperature Alarm (TA)
If the device is in the critical range, a warning signal is applied to the interface.
Over Temperature Thermal Shutdown (OT)
The device has a thermal monitoring: shutdown with automatic restart. The OT
signal is applied to the interface.
Fan Failure Monitoring (FF)
If it comes to a fan failure or blocking, a signal is applied to the interface. The
speed signal of the fan is monitored. Thus, even a creeping fault is detected at an
early stage and there is a warning long sold separately in front of a fan failure.
3D Heat Dissipation
Our aligned and controlled heat dissipation design opens possibilities that are
formerly being reserved to custom design power supplies: Steplessly hard mount
of the CPS-EX2000/3000 power supply modules in a 3D-room.
In practice that means that one can mount the modules into every angle
imaginable. Our 3D heat dissipation (3D-HD) ensures optimal cooling in each
mounting position you may consider.
Design-to-Service:
Most recorded failures in the field concern the signal interface of a power supply.
Camtec offers new concept of design-to-service that allows the customer easily to
exchange the interface himself in the field. The analogue and digital interfaces
apply plug & play self calibrating and can be used independent from the model
CPS-i/EX/EP 2000 & 3000 Thus, system down cost is being reduced and only a
small amount of spare parts need to be stocked by the customer.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.4/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Technical Data Table
AC Input Range
184-264Vac
AC Input Frequency
47-63Hz
DC Input Range
250-375Vdc
AC Input Rated
230Vac <10A
DC Input Rated
250Vdc <9,3A 375Vdc <6,2A
DC Voltage Rated
24Vdc
36Vdc
48Vdc
72Vdc
110Vdc
DC Voltage Programmable
24 - 30Vdc
30 - 45Vdc
45 - 58Vdc
58 - 90Vdc
90 - 150Vdc
DC Current Programmable
42 - 84A
28 - 56A
21 - 42A
14 - 28A
9,1 - 18,2A
Over Voltage Protection
35Vdc
52,5Vdc
68Vdc
105Vdc
175Vdc
Over Current Protection
92A
62A
46A
31A
20A
Ripple Noise 230Vac 20MHz
35mVpp
35mVpp
75mVpp
100mVpp
200mVpp
Auxiliary Voltage
12Vdc/0,5A accuracy ±0,5V R&N 30mVpp, not influenced from SB, SD, INH operations
Power Rated
2000W, 184-264Vac
Cooling
Continuously controlled and monitored fans from EBM Papst (Germany)
Efficiency
typ. 92-94% 230Vac at full load
Power Factor Control (PFC)
0,99 / 230Vac full load
Short Circuit Resistance
yes
Open Circuit Protected
yes
Base Load (OCP)
Non required (open circuit protected)
Load Regulation
< ± 0,05% 0-100%
Load Regulation Time
<1ms on load switch 10-100%
Rise Time and Latency
0V – Voutmax, 15ms over all
Accuracy
Ureg: ≤ ± 0,5%, Ireg: ≤ ± 1%, Umon: ≤ ± 0,5%, Imon: ≤ ± 1%, Uref: ≤ ±1%
Temperature Control
yes, thermal shutdown & autorecovery (+70°C, outside measuring point distance 10mm)
Hold Up Time
>30ms 230Vac mains buffering at full load
Inrush Current
<14,6Aeff <20,7Apeak 230Vac active electronic inrush protection (no simple NTC)
Startup Delay
typ. 1s
Softstart
typ. 100ms
Ambient Temperature
- 20°C…+60°C operating, derating 2,5%/°C >50°C
Storage Temperature
- 40°C…+85°C
Ambient Conditions
Humidity 95% non-condensing @ 25°C, climate class 3K3, pollution degree 2
ROHS
2011/65/EU, (EU) 2015/863 conform
REACH
EG No. 1907/2006 conform
EMI
EN55032, conducted .024/.036/.048 class B / .072/.110 class A, all models radiated class A
EMS/EMI
EN61000-6-2,3,4
Safety
EN61010-1, EN61010-2-201, EN62368-1, EN60950-1, EN60204-1
Protection Class I
PE connection required
Leackage Current
Typical 1,9mA, <2,8mA, 230Vac 50Hz
Isolation Input to Output
3000Vac
Isolation Input to Case
2500Vac
Isolation Output to Case
500Vdc , ≥48Vdc= 2800Vdc
MTBF (IEC61709)
419500h (Meantime Between Failures: statistic time between failures after repairs)
MTTF (IEC61709)
146110h (Meantime To Failure: statistic time to ever fails)
Dimensions (HxWxD)
84x126,4x444mm | 3,3x5x17,5 Inch (without frontplate, note cable outlet in planning)
Weight
4,4kg / 9,7lbs
Input Power Connections
Neutrik NAC3FCA (locked by bajonett) included
Output Power Connections
Brass-Powerbars with metric M8 thread, a touch protection is included
Programming Time Vout [ms]
Model
24Vdc
36Vdc
48Vdc
72Vdc
110Vdc
Slew Rate 90-10%, 10/100% Load, [ms] typ.
70/7,0
30/3,0
46/4,6
35/3,5
47/4,7
Output Capacity, [mF] typ.
19,4
3,74
3,4
1,07
0,52
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.5/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Manual und Technical Details
Analog Interface CON1 (Connector Model Weidmueller 1277320000 = included)
Pin
Name
Type
Function
Signal
Remarks
1
AC OK-1
Output
Closers, Signal AC OK
Relay
Potential-free
2
DC OK-1
Output
Closers, Signal DC OK
Relay
Potential-free
3
AC OK-2
Output
Center, Signal AC OK
Relay
Potential-free
4
DC OK-2
Output
Center, Signal DC OK
Relay
Potential-free
5
AC OK-3
Output
Break, Signal AC OK
Relay
Potential-free
6
DC OK-3
Output
Break, Signal DC OK
Relay
Potential-free
7
SB
Input
Control Signal Standby
Switch / Open Collector
8
SD
Input
Control Signal Shutdown
Switch / Open Collector
9
DGND
-
Digital Ground
-
10
+12V AUX
Output
Auxiliary Voltage
12Vdc/0,5A ±0,5V 30mVpp
≤1000uF, O-Ring Diode
11
DGND
-
Digital Ground
-
12
INH
Input
Control Signal Inhibit (Interlock)
Switch
Analog Interface CON2 (Connector Model Weidmueller 1277330000 = included)
Pin
Name
Type
Function
Signal
Remarks
1
DGND
-
Digital Ground
-
2
TEMP
Output
Temperature Control
Voltage 10mV/°C
3
DGND
-
Digital Ground
-
4
NC
NC
Not Connected
No Function
5
DCF
Output
Signal DC Failure
Open Collector
6
ACF
Output
Signal AC Failure
Open Collector
7
FF
Output
Signal Fan Failure
Open Collector
8
INH
Output
Signal Inhibit Active
Open Collector
9
OT
Output
Signal Over Temperature
Open Collector
10
TA
Output
Signal Temperature Alarm
Open Collector
Early warning
11
OCP
Output
Signal Over Current Protection
Open Collector
12
CC
Output
Signal Constant Current Mode
Open Collector
13
OVP
Output
Signal Over Voltage
Open Collector
14
CV
Output
Signal Constant Voltage Mode
Open Collector
Analog Interface CON3 (Connector Model Weidmueller 1277340000 = included)
Pin
Name
Type
Function
Signal
Remarks
1
AGND
-
Analog Ground
-
2
Imon
Output
Current Monitor
0-5Vdc / 5mA
3
NC
NC
Not Connected
No Function
4
Umon
Output
Voltage Monitor
0-5Vdc / 5mA
5
CS
I/O
Current Share Bus (CSB)
Parallel Operation
Bidirectional
6
Ireg-OUT
Output
Current Programming Slave
0-5V / 5mA
7
AGND
-
Analog Ground
-
8
Ureg-OUT
Output
Voltage Programming Slave
0-5V / 5mA
9
AGND
-
Analog Ground
-
10*
Iadj
Output
Potentiometer Connection Current
With external poti
11
Uref
Output
Reference Voltage
5,2Vdc / 5mA
12*
Uadj
Output
Potentiometer Connection Voltage
With external poti
13
CS
I/O
Current Share Bus (CSB)
Parallel Operation
Bidirectional
14
Ireg-IN
Input
Current Programming
0-5V
15
AGND
-
Analog Ground
-
16
Ureg-IN
Input
Voltage Programming
0-5V
Analoge Interface CON4 (Connector Model Weidmueller 1277290000 = included)
Pin
Name
Type
Function
Signal
Remarks
1
Sense -
Input
Sense Connection
-
2V / load line
2
Sense -
Input
Sense Connection
-
3, 4
NC
-
Must not be connected
5, 6
NC
-
7
Sense +
Input
Sense Connection
-
2V / load line
8
Sense +
Input
Sense Connection
-
PIN10/12* when no external control signal shall be used the device can be set with internal potentiometers. Please connect
Pin10 with Pin14 and Pin12 with Pin16 to operate this mode.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.6/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Schematic of the internal circuits CON1 - 4
NC
NC
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.7/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
CON1
Push In
0,14-
1,5mm²
AWG26-16
CON2
CON3
CON4
DC +/-
M8
200A/60°C
250Vac
20A
Neutrik
PowerCon®
3x2,5 mm²
Neutrik NAC3FCA
Copy of the original instruction:
http://www.neutrik.com/de/powercon/powercon-20-a/nac3fca
- Interface pluggable Push-Pull-Connectors from Weidmueller (included)
- Input Power Connector Neutrik NAC3FCA (included)
- Output Power Connection M8 Powerbars
- Lock-Pins snap into the 2U/3U 19“-subrack
WARNING OUTPUT CONNECTION INSTRUCTION:
Mount the cable lugs directly on the output terminals followed by a washer, a split washer and a
screw. Failure to follow the order can result in excessive heat! Recommended torque: 8-10Nm. Use
only screws, washers and split washers supplied with this unit.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.8/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
LED Operating Signal
CV/OVP
CV Constant Voltage Mode LED lights Green
OVP Overvoltage maloperation or interference voltage LED lights Red
CC/OCP
CC Constant Current Mode LED lights Yellow
OCP Over Current Protection LED flashes Red, also see >>Fuse Mode<<
TA/OT
TA Temperature Alarm LED lights Yellow, warning temperature shutdown pending
OT Over Temperature Shutdown LED lights Red
INH/FF
INH Inhibit (Interlock) Shutdown LED lights Yellow
FF Fan Failure LED lights Red
SD/SB
SD Shutdown LED lights Yellow
SB Standby LED lights Red
Configuration of the Current Share Bus (CS) and Over Current Protection
Mode
S11
S12
CS active
0
CS non-active
1
Fuse Mode
0
Continuous Mode
1
Warning! CS (Current Share Mode) only applies when a current distribution must take place while parallel
operation mode. In single or parallel operation without the need of CS, always switch CS with S11 to OFF=1.
Factory set: CS non-active (S11=1), Continuous Mode (S12=1)
Note that for DIGI3201 interface equipped unit settings will be made with the browser in the software.
Programming/Monitoring V/C Analog Interface (Ureg-IN/Ireg-IN) (Umon/Imon)
The standard programming of the CPS-EX Series is an analog interface. The output voltage is linearly
proportional to the adjusted analog control signal.
The monitor signal is analog linear to the output voltage. The monitor signal for current and voltage is the real
value that is measured directly at the output of the power supply. If a sense line is connected to compensate for
the voltage drop across the load lines, the monitor signal is exactly the value that is measured at the connection
point of the sense line. The description of the power supply in the sense operation is carried out in a separate
section.
The analog inputs and outputs are non-floating. The mass is connected to the DC negative output.
The burden of the control voltages is 1MΩ. The latency to full compensation of V/C on the interface from 0-
100% is 15ms for all CPS-EX models.
Programming V/C via Potentiometer (Uadj/Iadj) – Stand Alone Operation
The power supply is equipped with 2 potentiometers Uadj and Iadj for setting voltage and current.
Connect each Uadj and Iadj of CON3 to the inputs Ureg-IN and Ireg-IN. If one of the two potentiometers is not
used, the other value can still be programmed via the interface. In such case, only the control signal 0-5V can
be used.
Fuse Mode
The Fuse Mode can be used mode to prevent a major damage to a defective load. Fuse Mode can be activated
via the associated switch S12 DIP switch.
If the device is in the Fuse Mode (DIP switch S12=0), the device switches off when the constant current
operation is taking longer than typ. 5s. The red OCP LED flashes with a period of 0,4s. The PSU is locked. The
interlock can be canceled by the power supply is either switched off by the mains input, SB or SD contact for a
moment.
Continuous Mode
If you select Continiuous Mode at DIP switch S12 (DIP switch S12=1), the device provides continuous power. It
also applicable in the Constant Current Mode. Factory setup = Continuous Mode
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.9/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Over Load Behaviour
The CPS-EX changes from the standard operation mode into the high current mode when high and quick
overload occurs. Thus, it provokes a restart after a 30ms break and delivers continuous current to the output.
This special behaviour is a protection for the power supply and for the connected load.
Compensation of Load Line Drop Voltage (Sense ++/--), standard operation mode
The CPS-EX power supply has a Sense Mode to compensate for the voltage drop over long load lines. The
compensation amounts to a maximum of 2V per load line. Under certain circumstances, it can be expected to
apply more complicated external interference suppression. If sense is not used, CON4 Sense +/+ and Sense -/-
shall necessarily be connected by short bridges to the power outputs (factory setup).
Sense operation: Remove the bridges between Sense +/+, Sense -/- and the power outputs. Connect the sense
lines directly to the load. It is irrelevant which of the local connections Sense +/+ and Sense -/- are applied. Pay
attention to the polarity of plus and minus of the load to prevent damage to the power supply. To avoid
interference, twist the sense lines. To reduce inductive effects, we recommend that the load lines position is
close to each other. To supply a pulsating load, the use of an electrolytic capacitor and a cermic capacitor has
proved. The internal Over Voltage Protection (OVP) of the power supply controls the DC power directly to the
DC output terminals. In case of an error the OVP acts automatically (see OVP values corresponding table).
Operating in the sense mode requires that the maximum output voltage will not be exceeded. Maximum 2V per
load lead can be compensated. The voltage drop in the load lines decreases the maximum output voltage
rating. Example of a 30V unit: if the total voltage drop in the load leads is 2V you must subtract this value from
the maximum programmable output voltage 30V – 2V = 28V maximum available voltage at the load.
The sense terminals are directly connected to the power outputs.
Lokal Sensing Remote Sensing
(factory setup) (twisted sense lines)
WARNING! PROTECT TO MIX UP SENSE CONNECTIONS. THIS COULD CAUSE SERIOUS DAMAGE TO
THE DEVICE.
Compensation of Load Line Drop Voltage (Sense ++/--) battery charger operation mode
Remote Sensing as a battery charger
If the CPS-EX power supply unit is used as a battery charger, it is recommended to refrain from sensing. It can
lead to severe damage to the power supply, if the polarity of the sense line is confused (field experience: such
error often occurs when system service is required, e.g., when the batteries are changed). If it is necessary to
use sensing, proceed as described in the figure below. Proven approaches are 250mA for the fuses and 3...5A
load capacity of diodes.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.10/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Master-Slave Mode (Ureg-OUT/Ireg-OUT)
The CPS-EX power supplies offer the possibility of Master-Slave operation. To increase the output current, up
to 5 units of the same type and output voltage can be connected in parallel. One device takes over the function
of the master, the other devices assume the slave function. The Current Share Bus (CS) marries the involved
power supplies together. The CS bus allows a symmetrical current distribution in parallel operation of several
identical CPS-EX units.
Define a power supply as the master. Set S11=0 for all the involved units. The signals of the interface are
looped together. Connect Ureg-OUT and Ireg-OUT of the master to Ureg-IN and Ireg-IN from to slave. Connect
the corresponding Ureg-OUT/Ireg-OUT from the slave to the next slave, etc. All the monitoring signals of each
power supply are still available.
Current Distribution in Parallel Mode (CS), CSB Current Share Bus
In parallel operation, a uniform current distribution between the participating power supplies is important. To
prevent one of the power supplies going early into the current limitation and display error message. An uneven
load and thus premature aging of the participating devices is prevented.
Connect CON3 contact 5 (CS) to contact 13 of the slave. Are other devices involved in the parallel operation,
you may grind the CS bus through from unit to unit. The current division between the devices will be performed
automatically. The accuracy of the current distribution is ±5% at Iout ≥ 0,5 x Iout max. Derate the total output
current by 5% to prevent unit overload condition (signaling).
External Shutdown (SD)
The power supply is set to the Shutdown mode, when the
control input is either shorted via a relay contact, a switch
contact or an NPN transistor with open collector (voltage drop
<1V, current typ. 1,5mA). Alternatively, a voltage of 10 to 30V
(typ. 12V/1.5mA, 24V/5.5mA) can be applied.
If the shutdown repeals the power supply starts with a delay of
35ms.
Using the soft start, the current and the voltage rises within
100ms continuously to the default set values. Between control
input SD and power output is a reinforced Isolation of max.
400Vdc and a basic isolation of max. 600Vdc working voltage.
Standby (SB)
The power supply is switched to standby mode when the
control input is shorted optionally via a relay contact, a switch
contact or an NPN transistor with open collector (voltage drop
<1V, current typ. 1.5mA). Alternatively, a voltage of 10 to 30V
(typ. 12V/1.5mA, 24V/5.5mA) can be applied.
If the standby repeals, the power supply starts with a delay of
500ms.
Using the soft start, the current and the voltage rises within
100ms continuously to the default set values. Between control
input SB and power output is a reinforced Isolation of max.
400Vdc and a basic isolation of max. 600Vdc working voltage.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.11/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Inhibit / Interlock (INH)
The power supply is equipped with a control input Inhibit (INH)
to interlock a DC-shutdown of the power supply.
For the nominal operation of the power supply the connections
of the control input "INH" must always be short-circuited.
The power output is switched off as soon as the connection
between the contacts of the control input INH is interrupted.
If Inhibit is repealed, the power supply starts with a delay of
35ms. Using the soft start, the current and the voltage rises
within 100ms continuously to the default set values. Between
the INH contacts applies a current of typical 2mA.
! Warning against damage in case of incorrect connection assignment
Never apply any external voltage to the control input INH. Never connect a resistor to the INH interface. The
INH can only be connected to a floating contact (e.g., mechanical switch or relay). Between control input INH,
power input and power output is a reinforced Isolation of max. 400Vdc and a basic isolation of max. 600Vdc
working voltage.
Signal Inhibit (INH) Interlock
INH is high as soon as the connection between the contacts of the control input INH is interrupted.
Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
Auxiliary Voltage +12V (AUX)
The power supply offers an auxiliary voltage 12V/500mA. The accuracy is ±500mV. Ripple & Noise 30mVpp.
The auxiliary voltage is not affected by the control signals Standby (SB), Shutdown (SD) and Inhibit (INH) and
remains always active. Between auxiliary voltage and the power output is a reinforced Isolation of max. 400Vdc
and a basic isolation of max. 600Vdc working voltage.
DC-OK Relay (DC Power Good)
The signal DC OK has potential-free relay contacts (changeover). The contacts of CON1 Pin2 and CON1 Pin4
are closed (relay coil is energized) when the power output is active.
The contacts CON1 Pin2 and CON1 Pin4 are open when the power output is inhibited by SB, SD, INH, ACF,
OT, FF, OVP or a defective PFC. Contact load (resistive load): 30Vdc/1A, 60Vdc/0.3A, 30Vac/0.5A. Between
the intermediate relay contact and the power output is a reinforced Isolation of max. 400Vdc and a basic
isolation of max. 600Vdc working voltage.
DC Fail Signal (DCF)
DCF is high when the power output is disabled by SB, SD, INH, ACF, OT, FF or OVP. Output Open Collector
IMAX=10mA, VLOW≤0,6V, VMAX=30V.
AC-OK Relay (AC Power Good)
The Power Good relay reports whether the input voltage is too low or missing. The notification signal AC OK is
generated with potential-free relay contacts (changeover).
The contacts of CON1 Pin1 and CON1 Pin3 are closed (relay coil is energized) when the input voltage is higher
than typ. 175Vac or 210Vdc (switch-on). The contacts of CON1 Pin5 and CON1 Pin3 are closed (relay coil is
not energized) when the input voltage is lower than typical 165Vac or 145Vdc (turn-off). Contact load (resistive
load): 30Vdc/1A, 60Vdc/0.3A, 30Vac/0.5A.
Between the relay contacts and the power output is a reinforced isolation of max. 400Vdc and a basic isolation
of max. 600Vdc working voltage.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.12/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
AC Fail Signal (ACF)
The alarm signal ACF is high when the input voltage is lower than typ. 165Vac or 145Vdc.
The alarm signal ACF is low when the input voltage is higher than typ. 175Vac or 210Vdc.
Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
Over Voltage Protection Signal (OVP)
If an over-voltage occurs to the output (for example, defective components, external feed voltage), it is followed
by the shutdown of the power output. A periodic restart attempts (ticker operation period 1s) and a message is
triggered: The alarm signal OVP is high. Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
Constant Voltage Mode (CV)
The signal CV is high when the power supply operates as a constant voltage source. Output Open Collector
IMAX=10mA, VLOW≤0,6V, VMAX=30V. When OVP, INH, SB, SD, FF, OCP, OT or a defective PFC occur the mes-
sage signal CV is low because the power output is switched off. The change between the CV and the CC mode
is automatic. Please pay attention to the DIP switch setting of the Fuse Mode to avoid provoking malfunction.
Constant Current Mode (CC)
The signal CC is high when the power supply operates as a constant current source. Output Open Collector
IMAX=10mA, VLOW≤0,6V, VMAX=30V. When OVP, INH, SB, SD, FF, OCP, OT or defective PFC occur the mes-
sage signal CC is low because the power output is switched off. The change between the CV and the CC mode
is automatic. Please pay attention to the DIP switch setting of the Fuse Mode to avoid provoking malfunction.
CC-Mode & Over Current Protection in the Fuse Mode (OCP)
The alarm signal OCP is high, when the constant current
operation appears for more than typical 5s (Fuse Mode DIP
switch S12=0).
Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V. By
switching the unit off and on from SB, SD, or the mains, the
power supply returns into operation.
The power output is switched off. The PFC and the fans are
not switched off. In the SB or SD mode the message signal
OCP is low. In the INH mode the status of the power supply
does not change.
Temperature Control Signal (TEMP)
The power supply has a temperature monitor. Here, the temperature of the power supply is continuously
measured. The signal TEMP provides a voltage UTEMP corresponding to the internal temperature of the power
supply TINT: TINT=UTEMP/(10mV/°C), UTEMP in mV. Measuring range: +2...+150°C. Output impedance 2kOhm.
Between the signal TEMP and the power output is a reinforced Isolation of max. 400Vdc and a basic isolation
of max. 600Vdc working voltage.
Temperature Warning (TA)
The power supply has a Temperature Warning. The signal provides the user the option to save important data
before the power supply shut down from OT, or to put his system in the emergency mode. The alarm signal TA
is high when the internal temperature of the power supply is approximately 5°C below the overtemperature
protection threshold. Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.13/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Over Temperature Shutdown (OT)
The alarm signal OT is high when the temperature of the power supply is higher than the over-temperature
protection threshold. Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
Fan Fail Signal (FF)
The power supply fans are continuously monitored. FF occurs when one or both fans have an error (lower
speed due to bearing contamination, blockage, or failures). A failure message is sent: The status signal FF
applies high. Output Open Collector IMAX=10mA, VLOW≤0,6V, VMAX=30V.
C/V Chart and Operating Point
The output voltage set Vout is always linear proportional to the control signal
Ureg.
The desired control signal is selected via the DIP switcher:
0-5V, 0-10V, 0-20mA oder 4-20mA.
Model
Value UA1 (V)
Value IA1 (A)
Value UA2 (V)
Value IA2 (A)
Pmax (IA1/IA2)
CPS-EX2000.024
30Vdc
66,7A
24Vdc
84A
2001/2016W
CPS-EX2000.036
45Vdc
44,4A
36Vdc
56A
1998/2016W
CPS-EX2000.048
58Vdc
34,5A
48Vdc
42A
2001/2016W
CPS-EX2000.072
90Vdc
22,2A
72Vdc
28A
1998/2016W
CPS-EX2000.110
150Vdc
13,3A
110Vdc
18,2A
1995/2002W
Inrush Current Limiter (electronic)
The power supply unit has an electronic current limiter
(230Vac=14,6Arms/20,7Apeak).
It is a precisely working circuit instead of a usual simple NTC
solution. The accuracy is ±10%, regardless of the operating
temperature and the duty cycles (interval ≥10s). We recommend
the smallest circuit breaker a characteristic B with 16A.
Temperature Monitoring & Derating
The maximum ambient temperature during operation is + 60°C. If the
overtemperature protection is activated, the power supply but not the fan is
switched off.
The measuring point is 50mm outside the power supply at the front side
(fan/blower input). The power supply unit starts automatically when it has
cooled down.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.14/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Open Collector Circuit Interface
Between all open collector outputs and the power output is a reinforced
isolation of max. 400Vdc and a basic isolation of max. 600Vdc working
voltage.
(Note: this applies to all signals from CON1 and CON2, regardless of whether
they are designed as open collector, or not)
Series Operation
Two or more units of the same model and output voltage can be operated up to a total voltage of 600Vdc in
series (not applicable to EN62368-1). Due to the dielectric strength of the internal components used, only the
models with an output voltage of 48Vdc and later are approved for series operation. Other power supplies are
not approved for series operation above 60Vdc.
If the units are remotely controlled via the analog interface it is compulsory to use a potential-free control
voltage!
Parallel Operation & N+1 Decoupling
To increase the overall power of the power supply, up to 5 units of the same model with the same output
voltage may be operated in parallel. We recommend using a busbar for the DC power connector. Make sure
that the cable lengths and cable cross-sections of all power supplies to the busbar or to the star point are
identical. Allow proper connection for low contact resistance. If you want to use the sensing function, connect it
also to the star point or busbar. To avoid measurement errors, select the line length from the neutral point or
from the busbar to the load as short as possible and use the maximum possible conductor cross-section.
The CPS-EX models have no internal O-ring diode, to operate the devices N+1 redundant.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.15/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.16/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Electrical Safety (Factory-Test / Field-Test Owner)
¹) ≥48Vdc= 2800Vdc
Type and factory test are the manufacturer. While repeating damage can
happen to the power supply unit. For the field test (owner) follow the below instruction:
a)
Use suitable test equipment, raising the voltage slowly
b)
Short circuit L1 and N, and all the DC output terminals.
c)
Use only test voltages of 50/60Hz. The outputs are unearthed and
therefore they have no resistance to GND/PE.
d)
If the residual voltage is ≥60Vdc, observe the safety standards.
Use only specially insulated screwdriver to trim the Ua/Ia.
ANALOGUE INTERFACE
T
A
B
C1)
D
E
Type Test
60s
2500Vac
3000Vac
500Vdc
3000Vac
500Vdc
Factory Test
5s
2000Vac
2000Vac
500Vdc
1000Vdc
500Vdc
Field Test
2s
2000Vac
2000Vac
500Vdc
1000Vdc
500Vdc
Cut-off current setting >25mA
>25mA
>1mA
>1mA
>1mA
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.17/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Mechanics
Aluminium-housing IP20.
Cooling is achieved via
front-to-rear fans.
To ensure adequate heat
dissipation, 50mm to the
front and 150mm
blockade-free distance
from the device back wall
must be guaranteed.
The harnesses are to be
designed and installed to
that the air outlet of the
unit is not being blocked.
In a rack mounting of
multiple subracks, the rear
distance of the cable-
management increases,
depending on the type of
the air duct.
An optional cable-
accession assistance for
the racks will be available
soon.
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.18/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
19“ Subrack 2U & 3U
2U Subrack for 1-3 CPS-EX2000 with up to 6kW continuous power
3U Subrack for 1-5 CPS-EX2000 with up to 10kW continuous power
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.19/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Wall Mount Option & 3D Heat Dissipation (3D-HD)
Our aligned and controlled heat dissipation design opens possibilities that are formerly being reserved to
custom design power supplies: Steplessly hard mount of the CPS-EX2000/3000 power supply modules in a 3D-
room.
In practice that means that one can mount the modules into every angle imaginable. Our 3D Heat Dissipation
(3D-HD) ensures optimal cooling in each mounting position you may consider.
All you may consider is to make sure, that at least a distance of 5cm (2 Inch) to the front cooling slots and 15cm
(6 Inch) to the rear cooling openings are guaranteed to prevent from blocking the airflow. The cabling must also
not block the heat dissipation.
When the CPS-EX2000/3000 is hard mounted the optional front plates cannot be used. The standard control
LEDs allow visualization from any mounting position (see below drawing).
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.20/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Available Options
Test Certificate and Calibration
Optionally we offer with the delivery of a CPS power supply a Manufacturer's Inspection Certificate of electrical
setpoint / actual values. The power supply then is "calibrated". Such Manufacturers Calibration Certificate for
each power supply can uniquely be assigned via the device serial number.
A manufacturer calibration of a CPS can frequently be done via controlled recirculation on a regular basis.
Please request the help of your local CPS dealer or contact us directly: [email protected]
Ordering Codes
Product Code
Information
Article Number
CPS-EX2000.024(R2)
24Vdc model incl. analogue interface
3041110002CA
CPS-EX2000.036(R2)
36Vdc model incl. analogue interface
3041110003CA
CPS-EX2000.048(R2)
48Vdc model incl. analogue interface
3041110004CA
CPS-EX2000.072(R2)
72Vdc model incl. analogue interface
3041110005CA
CPS-EX2000.110(R2)
110Vdc model incl. analogue interface
3041110006CA
Certifcate Calibration
Separate works certificate for manufacturer calibration of the power supply
4031107001CA
19“ Frontplate 2U
Including mounting material
2201006001CA
19“ Frontplate 3U
Including mounting material
2201007001CA
19“ Blindplate 2U
Including mounting material
2201009001CA
19“ Blindplate 3U
Including mounting material
2201010001CA
19“ Subrack 2U
3 Modules mountable only in conjunction with front panel 2U orderable
2201004001CA
19“ Subrack 3U
5 Modules mountable only in conjunction with front panel 3U orderable
2201005001CA
19“ Rack-Rail
2x Support Rails for rack mount, mounting kit included
2201008001CA
Hard Mount Holder narrow
2x Holder for narrow wall mount, mounting kit included
2201011001CA
Hard Mount Holder flat
2x Holder for flat wall mount, mounting kit included
2201012001CA
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany P.21/21 (07/2017.01.3)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77 www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Safety regulations: Please read these instructions completely before using the equipment. Keep these
instructions on to hand. The device may only be operated by trained specialist staff.
Installation:
1) The device is designed for devices and systems
that meet the standard requirements for hazardous
voltages, power, and fire prevention.
2.) Installation and service only by trained specialists.
The AC power must be switched off. The work is to be
labelled; accidental reconnection of the system must
be prevented.
3.) Opening the device, its modification, loosening
bolts, or operation outside the specified herein
specification or in an unsuitable environment, has the
immediate loss of warranty to follow. We disclaim any
responsibility for any resulting damage to persons or
things.
4.) Note: The device must not be operated without an
upstream circuit breaker (CB). We recommend the use
of B-Type 16A. It is prohibited to use the unit without
PE. It may be necessary upstream device has a power
switch.
Warning:
Non-compliance these warnings can result in fire
and serious injury or death.
1. Never operate device without PE connection.
2. Before connecting the device to the AC
network, make wires free of voltage and ensure
that it cannot accidentally switch on.
3. Allow neat and professional cabling.
4. Never open nor try to repair the unit. Inside
are dangerous voltages that can cause electrical
shock hazard.
5. Avoid metal pieces or other conductive
material to fall into the item
6. Do not operate the device in damp or wet
conditions
7. Do not operate the unit under EX-conditions
All parameters after 15 minutes of continuous operation at full load / 25°C / 230Vac 50/60Hz, unless otherwise indicated.