Datalogic PowerScan D8300 Reference Manual

Text of the manual

Ask the experts at POSMicro.com.

1.800.241.6264 Live Chat Now [email protected] Monday - Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING* SE Habla Español *Free ground shipping to the continental USA on orders over $100. For Help Call 1.800.241.6264 Datalogic PowerScan D8300 Manual More information available at POSMicro.com

Datalogic Scanning, Inc.

959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this docu- mentation or the procedures described therein may be reproduced or transmit- ted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scan- ning”). Owners of Datalogic products are hereby granted a non-exclusive, revo- cable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprie- tary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.data- logic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publica- tions, please let us know via the "Contact Datalogic" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A and the E.U. All other brand and product names referred to herein may be trademarks of their respective owners.

INTRODUCTION .......................................................................................... 1

2 INSTALLATION ............................................................................................ 2 2.1 PowerScan® D8330 Interface Cable Connections ........................................ 2 2.2 BC-80X0 Interface Cable Connections ......................................................... 4 2.3 RS-232 Connection ....................................................................................... 5 2.4 USB............................................................................................................... 5 2.5 IBM USB POS ............................................................................................... 6 2.6 WEDGE Connection ..................................................................................... 7 2.7 PEN Emulation Connection ........................................................................... 7 2.8 Network Connections .................................................................................... 8 2.8.1 BC-8060 Network Connectors ...................................................................... 8 2.8.2 Network Cabling ............................................................................................ 9 2.8.3 Network Termination ................................................................................... 10 2.9 PowerScan® M8300 Battery Maintenance .................................................. 11 2.9.1 Battery Charging ......................................................................................... 11 2.9.2 Replacing PowerScan® M8300 Batteries .................................................... 11 2.10 Mounting The BC-80X0 / C-8000 Cradle .................................................... 12 2.10.1 Desktop Mounting ....................................................................................... 13 2.10.2 Wall Mounting ............................................................................................. 16 3 POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS .................. 18 3.1 Stand-alone Layouts ................................................................................... 18 3.1.1 Point-to-Point Reader Layout ...................................................................... 18 3.1.2 Stand-Alone Layout with Multiple Readers ................................................. 18 3.1.3 Multiple Stand-Alone Layouts ..................................................................... 19 3.1.4 C-BOX Layout ............................................................................................. 20 3.2 Multidrop STAR-System™ Network Layouts .............................................. 21 3.2.1 Host Master Layout ..................................................................................... 21 3.2.2 BC-8060 Master Layout .............................................................................. 22 3.2.3 Master BC-8060 Network Troubleshooting ................................................. 23 4 CONFIGURATION ...................................................................................... 24 4.1 Configuration Methods ................................................................................ 24 4.1.1 Reading Configuration Barcodes ................................................................ 24 4.1.2 Using Datalogic Aladdin™ .......................................................................... 24 4.1.3 Copy Command .......................................................................................... 24 4.1.4 Sending Configuration Strings from Host .................................................... 25 4.2 Setup Procedures ....................................................................................... 25 4.3 PowerScan® D8330 Setup .......................................................................... 26 4.4 PowerScan® M8300/BC-80X0 Point-to-Point Setup ................................... 26 4.5 PowerScan® M8300/BC-80X0 Stand-Alone Setup ..................................... 27 4.5.1 Using Multiple M-Series Readers with Same Cradle .................................. 29 4.5.2 PowerScan® M8300/STAR-Modem™ in Stand-Alone Mode ...................... 30

PowerScan® M8300/STAR-System™ Setup .............................................. 31

4.7 BC-8060 STAR-System™ Network Setup .................................................. 33 4.8 Interface Selection ...................................................................................... 35 4.9 USB Reader Configuration .......................................................................... 38 4.10 Changing Default Settings .......................................................................... 40 RS-232 Parameters .................................................................................... 41 USB Parameters ......................................................................................... 46 Wedge Parameters ..................................................................................... 52 Pen Emulation ............................................................................................. 59 Network Parameters ................................................................................... 64 Data Format ................................................................................................ 69 Power Save ................................................................................................. 81 Reading Parameters ................................................................................... 83 Decoding Parameters ................................................................................. 89 Code Selection ............................................................................................ 92 Advanced Formatting ................................................................................ 110 Radio Parameters ..................................................................................... 129 Display and Keypad Parameters (3-Key Model) ...................................... 135 Display and Keypad Parameters (16-Key Model) ..................................... 139 5 REFERENCES ......................................................................................... 160 5.1 RS-232 Parameters .................................................................................. 160 5.1.1 Handshaking ............................................................................................. 160 5.1.2 ACK/NACK Protocol.................................................................................. 161 5.1.3 FIFO .......................................................................................................... 162 5.1.4 RX Timeout ............................................................................................... 163 5.2 Pen Parameters ........................................................................................ 163 5.2.1 Minimum Output Pulse .............................................................................. 163 5.2.2 Conversion to Code 39 and Code 128 ...................................................... 163 5.2.3 Overflow .................................................................................................... 164 5.2.4 Output and Idle Levels .............................................................................. 164 5.2.5 Inter-Block Delay ....................................................................................... 165 5.3 Network Parameters ................................................................................. 165 5.3.1 Slave Address Range First/Last ................................................................ 165 5.3.2 Network Warning Message ....................................................................... 165 5.3.3 Reception Warning Message .................................................................... 166 5.3.4 Master Header/Terminator Selection ........................................................ 166 5.4 Data Format .............................................................................................. 166 5.4.1 Header/Terminator Selection .................................................................... 166 5.4.2 Define Special Key Sequence ................................................................... 168 5.4.3 Address Stamping ..................................................................................... 175 5.4.4 Address Delimiter ...................................................................................... 175 5.4.5 Time Stamping Format.............................................................................. 176 5.4.6 Time Stamping Delimiter ........................................................................... 176 5.5 Power Save ............................................................................................... 176 5.5.1 Sleep State ............................................................................................... 176

Enter Sleep Timeout ................................................................................. 177

5.6 Reading Parameters ................................................................................. 177 5.6.1 Trigger Signal ............................................................................................ 177 5.6.2 Trigger Click .............................................................................................. 177 5.6.3 Trigger-Off Timeout ................................................................................... 177 5.6.4 Reads per Cycle ....................................................................................... 177 5.6.5 Safety Time ............................................................................................... 178 5.7 Decoding Parameters ............................................................................... 178 5.7.1 Ink-Spread ................................................................................................ 178 5.7.2 Overflow Control ....................................................................................... 178 5.7.3 Interdigit Control ........................................................................................ 179 5.8 Advanced Formatting ................................................................................ 179 5.8.1 Match Conditions ...................................................................................... 179 5.9 Radio Parameters (M8300 Series Only) ................................................... 179 5.9.1 Radio Protocol Timeout............................................................................. 179 5.9.2 Radio RX Timeout ..................................................................................... 180 5.9.3 Power-Off Timeout .................................................................................... 180 5.9.4 Transmission Mode ................................................................................... 181 5.9.5 Beeper Control for Radio Response ......................................................... 181 5.9.6 Single Store .............................................................................................. 182 5.9.7 Batch Mode ............................................................................................... 182 5.9.8 Find Me (PowerScan® M8300 only) .......................................................... 184 5.10 Display Parameters (Some M8300 Models only) ...................................... 185 5.10.1 Display Mode ............................................................................................ 185 5.11 Configuration Editing Commands ............................................................. 186 5.12 Custom Default Configuration ................................................................... 187 5.13 Code Type Recognition............................................................................. 187 5.14 Configuration Copying Commands ........................................................... 188 5.14.1 Copy PowerScan D8330 Series ............................................................. 188 5.14.2 Copy PowerScan M8300 Series ............................................................ 189 5.14.3 Copy BC-80X0 .......................................................................................... 190 5.15 Default Parameters for POS Terminals ..................................................... 191 5.16 Firmware Upgrade .................................................................................... 192 5.17 16-Key PowerScan M8300-DK Display and Keypad Parameters ............ 193 5.17.1 16-key Keyboard Data Format Enable/Disable ......................................... 193 5.17.2 Scanner Code ID ...................................................................................... 194 5.17.3 Scanner Code Length ............................................................................... 194 6 MESSAGE FORMATTING ....................................................................... 195 6.1 Standard Message Formatting .................................................................. 195 6.2 16-key DK Message Formatting ................................................................ 196 6.3 Messages from Host to Reader ................................................................ 198 6.3.1 Cursor Control ........................................................................................... 199 6.3.2 Font Selection ........................................................................................... 199 6.3.3 Clearing Display ........................................................................................ 199 6.3.4 LED and Beeper Control ........................................................................... 200

Setting RTC .............................................................................................. 200

6.4 Messages from SCANNER Command Keys ............................................. 201 6.4.1 PowerScan M8300 keypad ....................................................................... 201 6.4.2 PowerScan M8300-DK 16-key keypad ..................................................... 202 7 TECHNICAL FEATURES ......................................................................... 203 7.1 PowerScan® D8330 .................................................................................. 203 7.2 PowerScan® M8300 .................................................................................. 204 7.3 PowerScan® M8300-DK 16-Key Model ..................................................... 205 7.4 BC-80X0 / C-8000 ..................................................................................... 207 7.5 System and Radio Features ...................................................................... 208 7.6 Status Indicators ....................................................................................... 208 7.7 Reading Tables ......................................................................................... 211

POWERSCAN® D8330/M8300 READERS

Figure A – PowerScan® D8330/M8300 Series Readers Figure B – PowerScan® M8300 Series Readers with Display LEDs Keypad Display Laser Output Window Laser Output Window POWERSCAN® M8300 Battery Cover POWERSCAN® D8330 Cable Connector LEDs Trigger

BC-80X0 / C-8000 CRADLES

Figure C – BC-8000 The label on the cradle contains LED indicators and a scan finder button. When the button is pressed, the cradle transmits a “broadcast” message. All properly configured scanners (Radio RX Timeout set to keep the radio “awake”) linked to that base (through a bind or a join sequence) and within radio range coverage will emit a beep sequence once every 2 seconds for 30 seconds. A scanner is considered to be linked when the last transmission ends properly. The scan finder works only in stand-alone layout (point to point or multiple readers). Figure D – C-8000 LEDs LEDs Scan Finder Button

Datalogic renews its range of industrial laser scanners introducing the PowerScan®

family: PowerScan® D8330 and PowerScan® M8300. Robustness and ergonomics remain unsurpassed: clearly audible beeper and bright "good read" LEDs for areas where noise levels are normally high; the aim mode, which helps point to the right code, has now been extended to the whole PowerScan® family. Optical parts are completely suspended on shock absorbers and a careful choice of the body materials, such as the co-moulded rubber, protect the PowerScan® from damage due to "falls". New enhanced architecture, based on an M16 high-speed microprocessor, enables exceptional performance for promptness and reading speed of standard codes as well as the ability to read poorly printed and damaged codes. Puzzle Solver Technology™, a patent from Datalogic, adds further strength to the PowerScan® powerful engine. In all applications where mobility is a value, the new PowerScan® M8300 represents the key to increase productivity and flexibility in the working area. PowerScan® M8300 communicates through a low power, license free radio in the 433 MHz band (910 MHz for USA version) and allows bi-directional communication between the base station and the host. PowerScan® M8300 also includes a display and either a 3 or 16-key push-button keypad. Thanks to these features, the operator can receive information from the host, interact with the central system and visualize the code read. The cordless system offers scalable solutions to solve simple applications and complex projects: • Point to point: each reader is associated with its own base station; • Multipoint: up to 32 readers transmit data to one base station; • Network: to cover a wide area, connecting up to 16 bases and 512 readers simultaneously working in automatic roaming. PowerScan® M8300 is 100% compatible with STAR-System™, the new Datalogic RF narrow band solution for mobile applications that provides the widest family of narrow band devices on the market. Your PowerScan® reader is supplied with its own Quick Reference Guide, which provides connection, diagrams, reading diagrams, basic application parameter settings, default values, and specific technical features. You can use either the Quick Reference Guide or this Manual for initial configuration in order to set the default values and select the interface for your application. This manual provides all the necessary information for complete mechanical installation and system software configuration.

Connections should always be made with power OFF!

CAUTION 2.1 POWERSCAN® D8330 INTERFACE CABLE CONNECTIONS The PowerScan® D8330 reader incorporates a multi-standard interface, which can be connected to a Host by plugging the correct interface cable into the connector and closing the cable cover. A. Rubber gasket B. Plastic boot C. Cable spacer D. Cover E. Strain relief

Follow the given procedure for correct cable insertion:

 Slip the cover over the cable.  Push the plastic boot into the rubber gasket. Take care that the tab on the plastic boot is aligned with the notch in the rubber gasket.  Push the plastic boot and gasket into the handle. Ensure that the “Front” marking on the plastic boot is facing out, with the arrow pointing towards the front of the scanner.  Insert the cable into the socket of the plastic boot.  Insert the cable spacer into the cable wire and slide it towards the handle.  Push the cover along the cable towards the reader, and hook it over the yellow “tooth”.  Insert the strain relief into the cover and tighten the screw to fix the whole assembly to the reader handle. Connections should always be made with power OFF! CAUTION Align 1 2 3 4 5 6 7 Notch Tab Arrow

BC-80X0 INTERFACE CABLE CONNECTIONS

BC-80X0 Connectors The BC-80X0 incorporates a multi-standard interface, which can be connected to a Host by simply plugging the correct interface cable into the Host connector, placed on the base of the cradle. In addition the cradle must be connected to an external power supply. Disconnecting the BC-80X0 Cable To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle. Push down on the clip while unplugging the cable. Interface Cable Power

BC-8060 Network Connectors

The multidrop network is a bus system which is propagated from one BC-8060 cradle to another using individual cables. This is possible thanks to the RS-485 connector on the front panel of the cradle. All cradles are connected together within the bus system through the Datalogic RS-485 splitter cable (CAB-428, part number 90A051950), which must be inserted in the RS-485 cradle connector. Obviously cable length is to be kept to a minimum as with all bus systems. Power Supply RS-485 (BC-8060only) MULTI-INTERFACE RS-232, USB, Wedge, PEN Emulation

The Multidrop line is made using RJ45 connectors and a cable having the following

specifications: • twisted pair AWG 24 wires • 120 Ω impedance • maximum network cable length 1200 meters Pin Function Multidrop Cables 1 RS-485 + 2 RS-485 - 3 N.C. 4 VDC – 5 VDC – 6 N.C. 7 VDC + 8 VDC + 5 2 RJ45 5 2 RJ45 1 1 VDC- RS-485- RS-485+ Twisted Pair – RS-485 bus 8 5 2 RJ45 8 5 2 RJ45 1 1 Twisted Pair – RS-485 bus Twisted Pair - Power supply VDC+ VDC- RS-485- RS-485+ When wiring the multidrop cables, note the following: Pin 8 (or 7) can be connected only if the power has to be propagated from a cradle to a STARGATE™ base station or STAR-Box™ converter via the cable. Pins 5 (or 4) should always be connected as reference ground. To avoid excessive voltage drop, it is recommended not to propagate power between BC-8060 cradles when used as battery chargers but to supply each cradle individually. The total number of devices, which can be connected to a single power supply, depends on the power supply voltage, the wire length and resistance and therefore the voltage drop. Do NOT connect VDC+ between network devices that are individually powered. Data only Data and Power Supply Pin 1

The first and last cradles of the chain (the two ends of the bus) must be properly

terminated. The cradle has an internal terminator that can be selected via jumper. For this selection you must open the device. No Termination Static Dynamic Terminator for Multidrop Network Static termination works for all network configurations. However, the network is always under load even when no data transmission takes place. Dynamic termination can be used for baud rates at or above 38400 and provides less load on the network when idle.

POWERSCAN® M8300 BATTERY MAINTENANCE

2.9.1 Battery Charging Once the system is connected and powered, you can place the PowerScan® M8300 into the cradle to charge the battery. When the reader is correctly inserted in the cradle, the "Reader" red LED on the cradle goes on to indicate that the battery is charging. The "Reader" green LED on the cradle goes on when the battery is completely charged. 2.9.2 Replacing PowerScan® M8300 Batteries To change the batteries in your PowerScan® M8300 scanner, press the black button or unscrew the fixing screw on the handle cover and extract the battery pack from the reader handle. When the batteries are extracted from the scanner, the timer maintains the current hour and date for about 1 minute. NOTE Replace the old battery pack with a new one by inserting it within the reader handle and pushing it until it clicks. Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force. WARNING 1 2

2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE

The cradle package contains the following items: BC-80X0 / C-8000 Cradle BC-80X0 Quick Reference / C-8000 Quick Reference BC-8000 Antenna 2 wall-mounting lock hinges 2 adhesive strips 4 rubber feet 1 horizontal base 1 inclined base The cradle (either BC-80X0 or C-8000) can be mounted for portable or fixed desktop usage, or it can be fixed to a wall. The horizontal base allows portable and fixed desktop usage, while the inclined base provides desktop and wall mounting guaranteeing a comfortable handling of the PowerScan® M8300 reader. BC-80X0/C-8000 Cradle mounted on the Horizontal Base BC-80X0/C-8000 Cradle mounted on the Inclined Base

For desktop usage, you can mount the cradle either on the horizontal base, for reduced

overall dimensions, or on the inclined base for a more ergonomic taking out and insertion of the reader onto the cradle. Horizontal base Top View Bottom View Inclined base Top View Bottom View Mounting Tabs (4) Mounting Holes (2) Rubber Foot Seat (4) Adhesive Strip Seat (2) Cable Channels Mounting Tabs (4) Mounting Holes (4) Cable Channels Adhesive Strip Seat (2) Rubber Foot Seat (4)

Portable Desktop Use

1. Correctly position the BC-80X0/C-8000 onto the base by sliding it along the mounting tabs until aligned. 2. Carefully clean the rubber foot seats of the base to remove any impurities that could reduce adhesion. 3. Remove the protective plastic from the rubber feet and stick them onto the bottom surface of the base. 4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight. Fixed Desktop Use For fixed desktop installation, use the adhesive strips or fixing screws (not provided) according to your needs. For mounting with adhesive strips: 1. Position the cradle onto the base by sliding it along the mounting tabs until aligned. 2. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion. 3. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.

4. Position the cables to be connected to the BC-80X0/C-8000 cradle along the

dedicated channels, as shown in the figures below: Horizontal Base Inclined Base 5. Remove the plastic from the other side of the strips and affix the base to the table. 6. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight. For mounting with screws: 1. Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels, as shown in the figures below: 2. Position the base on the table and affix it by means of the screws (not provided). 3. Position the cradle on the base by sliding it along the mounting tabs until aligned. 4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.

1. Remove the yellow caps and insert the two wall mounting lock hinges provided

with your cradle. 2. Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels (see figures at page 14).

If using the adhesive strips:

a. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion. b. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface. c. Remove the plastic from the other side of the strips and affix the base to the wall as indicated in the figure below. If using the mounting screws: 3. Using the mounting holes on the base as a pattern, mark the wall where you desire to mount the BC- 80X0/C-8000. 4. Drill the appropriate size holes and insert the threaded dowels (not provided) into the holes. 5. Position the base on the wall as indicated in the figure below and affix it by means of the screws (not provided). Inclined Base Wall-mounting 6. Attach the cradle on the base by sliding it along the mounting tabs until aligned. 7. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.

POWERSCAN® M8300 SYSTEM AND NETWORK

LAYOUTS There are two basic system layouts that can be employed: Stand-alone systems (including Point-to-Point layouts) and Multidrop STAR-System™ Networks. 3.1 STAND-ALONE LAYOUTS 3.1.1 Point-to-Point Reader Layout 3.1.2 Stand-Alone Layout with Multiple Readers In stand-alone systems, each cradle is connected to a single Host.

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS

19 3.1.3 Multiple Stand-Alone Layouts Many stand-alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses. Multiple Stand-alone Systems in the Same Area Since the cradles can communicate to multiple PowerScan® M8300 readers, you might find it useful to employ one or more C-8000 battery chargers in addition to the BC-80X0 cradle, so that the battery re-charging operation can be performed for several scanners at the same time. Host Host Host PowerScan® M8300 BC-80X0 BC-80X0 BC-80X0 BIND BIND BIND JOIN JOIN PowerScan® M8300 PowerScan® M8300

In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232

interface to a C-BOX connection box as part of a fixed scanner network. This allows the flexibility of a hand-held reading station integrated into a variety of fixed scanning applications so that all readers (both fixed and hand-held), in the system provide communications to the Host. The various C-BOX models provide many interface types for the Host system such as RS-232, RS-485, Profibus. JOIN BIND BC-80X0 C-Box Scanner System cables to Host PowerScan® M8300

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS

21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand-alone systems can operate in the same physical area without interfering with each other, it may be desirable to bridge data from multiple base stations in a network to a single Host. PowerScan® M8300 readers are compatible with STAR-System™ networks. These networks provide seamless active roaming for any RF reading device in the system. 3.2.1 Host Master Layout A. Host Master with STAR-Link™ B. STAR-Box™ converter C. BC-8060 slave cradles D. STARGATE™ base stations Example Multidrop STAR-System™ Network with Host as Master In this layout the Host acts as the Master using STAR-Link™ software. The Host is connected in RS-232 to a STAR-Box™ converter, which is connected to the first slave in the RS-485 network. In this way the base stations provide communications between a single Host and all 2.8.3 readers in the system. STARGATE™ base stations are used as slaves in this network. The Slaves at the ends of the network must be terminated (see the STARGATE™ and STAR-Box™ Installation Manuals and par. ). See par. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system configuration specifications. Internal Termination Internal Termination RS-485 + VDC RS-485 + VDC RS-232 A B C C D RS-485 Only CAB-428 Splitter

BC-8060 Master Layout

A. Host B. BC-8060 Master cradle C. BC-8060 Slave cradles D. STARGATE™ base station Example Multidrop STAR-System™ Network with BC-8060 as Master In this layout an BC-8060 cradle acts as the Master. The Host is connected to the BC-8060 Master using any one of the multi-standard interfaces (RS-232, USB, WEDGE, or PEN Emulation). The Master is then connected to the slaves in the RS-485 network. In this way the slave cradles provide communications between a single Host and all 2.8.3 readers in the system. STARGATE™ base stations can also be used as slaves in this network. The devices at the ends of the network must be terminated (see par. ). See pars. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system configuration specifications. Internal Termination Internal Termination RS-485 + VDC RS-485 Only USB, or RS-232, or Wedge, or Pen Emulation A B C C D RS-485 Only CAB-428 Splitter

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS

23 3.2.3 Master BC-8060 Network Troubleshooting Two diagnostic strings can be sent via RS-232 from the Host to the Master cradle in order to have feedback about the network itself. #+LSlave Returns a list of all the Slaves recognized at boot up. Example: In a network where the Master cradle has address 0188 and one Slave cradle with address 0001, the response is: 188 1 #+Alive Executes a continuous Alive request to the slave xxxx in order to monitor the performance of the connection. A diagnostic message is displayed on the Host. Example: If this command is sent for slave cradle with address 0032, the response is: /*32: BC-80X0 SOFTWARE RELEASE 1.00 20/10/2006*/ if there are no communication errors /*32: FAIL*/ if there are communication errors. To exit from this command, reset the system by cycling power to the Master cradle.

Reading Configuration Barcodes

This manual can be used for complete setup and configuration of your reader by following the setup procedures in this chapter (see par. 4.2 for an overview). If you wish to change the default settings, this manual provides complete configuration of your reader in an easy way. To configure your reader: 1) Open the folded page in Appendix C 2) Read the Enter Configuration code with the hex-numeric table and keep it open during the device configuration. ONCE 3) Modify the desired parameters in one or more sections following the procedures given for each group. , available at the top of each page of configuration. 4) Read the Exit and Save Configuration code ONCE , available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 1. 4.1.2 Using Datalogic Aladdin™ Datalogic Aladdin™ is a multi-platform utility program providing a quick and user- friendly configuration method via the RS-232/USB-COM interface. It also allows upgrading the software of the connected device (see the Datalogic Aladdin™ Help On-Line for more details). 4.1.3 Copy Command A previously configured device (Master), can be used to send its configuration directly to other devices of the same type (Slaves). The particular procedure for each device is given in par. 5.14.

Sending Configuration Strings from Host

An alternative configuration method is provided in Appendix A using the RS-232 interface. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily. 4.2 SETUP PROCEDURES For PowerScan® D8330 Series readers, follow the setup procedures in pars. 4.3, and 4.8. For PowerScan® M8300 Series readers, the setup procedures depend on two basic applications, Stand-alone or STAR-System™. Stand-alone applications allow communication with the Host by either the BC-80X0 cradle (par. 4.5), or by the STAR-Modem™ radio modem (par. 4.5.2). STAR-System™ applications allow communication with the Host through an RS-485 network by the STARGATE™ RF base station or by the BC-8000 cradle (par. 4.6 and par. 4.7). Proceed as shown in the following diagram: Begin Setup by choosing the setup procedure for your PowerScan® reader as indicated below. End of Setup Your reader is now ready to read barcodes using the default settings. Stand Alone Applications PowerScan® M8300/BC-80X0 Par. 4.4 Par. 4.7 Optional Par. 4.4.1 multiple readers per BC-8000 PowerScan® M8300/STAR-Modem™ in Stand Alone Mode Par. 4.4.2 PowerScan® D8330 Par. 4.3 Par. 4.7 STAR-System™ Network Applications BC-8000 Par. 4.6 STAR-System™ Applications PowerScan® M8300/STAR-System™ Par. 4.5 • STARGATE™ • BC-8000 Network • STAR-Modem™ in STAR-System™ Mode

POWERSCAN® D8330 SETUP

1. Read the restore default parameters code below. Restore PowerScan® D8330 Default Ì$+$*oÎ After reading the above code, go to par. 4.8 Interface Selection . 4.4 POWERSCAN® M8300/BC-80X0 POINT-TO-POINT SETUP A rapid configuration procedure has been devised for point-to-point applications where a single A special pre-printed bind-address label provided in the BC-80x0 base station package can be used to bind the PowerScan® M8300 reader to the base station with the address coded on the label. The address is also written numerically on the label to be easily recognized. Valid addresses are in the range from 0000 to 1999. Make sure that all cradles used in the same area have different addresses. reader is associated exclusively with its own BC-80x0 base station and where it is not necessary to set the Date and Time parameters. To rapidly configure your point-to-point application: 1. Apply the bind-address label onto the BC-80x0 base station as indicated in the BC-80x0 Quick Reference Guide. 2. When the BC-80X0 cradle is connected and powered, read the Bind-Address label to pair the PowerScan® M8300 to the BC-80X0 cradle. The green LED on the PowerScan® M8300 will blink: the reader is ready to be positioned onto the cradle. 3. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the PowerScan® M8300, and the green LED on the reader will go off. If it ever becomes necessary to change the reader, just read the bind-address label applied to the cradle and position the new reader onto the cradle. Do not use multiple readers with this configuration method. 4. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference Guide”. END of procedure. YOUR READER IS NOW READY TO READ CODES. Green LED

POWERSCAN® M8300/BC-80X0 STAND-ALONE SETUP

Read the restore default parameters code below. 1. Restore PowerScan® M8300 Default Ì$+$*oÎ Follow the procedure below to set the radio address and bind PowerScan® M8300 to the BC-80X0 cradle. 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY) 4. Set Time ÌIB'Î + four digits for Hour and Minutes (HHMM)

Set Radio Address

ÌRA0RFHÎ + four digits for the PowerScan® M8300 Address (from 0000 to 1999). All readers used in the same area must have different addresses. 6. Exit and Save Configuration Ì$-?Î 7. Read the Bind code to pair the PowerScan® M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following paragraph 4.5.1, ‘Using Multiple M8300 Series Readers with Same Cradle'. Bind Ì$+RN0$-IÎ The green LED on the PowerScan® M8300 will blink; the reader is ready to be inserted into the cradle. 8. Firmly insert the reader into the BC-80X0 cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the PowerScan® M8300, and the green LED on the reader will go off. green LED

9. Read the BC-80X0 restore default code:

Restore BC-80X0 Default Ì$+RX0$-qÎ Go to par. 4.8 Interface Selection . 4.5.1 Using Multiple M-Series Readers with Same Cradle If you want to use several M-Series readers with the same BC-80X0 cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join (step 7). 7. Join Ì$+RN1$-NÎ The green LED on the PowerScan® M8300 will blink: the reader is ready to be positioned onto the cradle. Complete step 8. END of procedure. All readers associated with the same cradle must have different addresses. CAUTION YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

PowerScan® M8300/STAR-Modem™ in Stand-Alone Mode

To configure a PowerScan® M8300 reader to communicate with STAR-Modem™ in Stand-alone Mode, follow the procedure in par. 4.5 substituting steps 6 and 7 with those below: 6. STAR-Modem™ Address ÌRSRÎ Read the code above and the four-digit address of the STAR-Modem™. 7. Exit and Save configuration Ì$-?Î END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

POWERSCAN® M8300/STAR-SYSTEM™ SETUP

The following procedure allows configuring a PowerScan® M8300 reader to communicate with various STAR-System™ devices such as STARGATE™ RF base stations. 1. Restore PowerScan® M8300 Default Ì$+$*oÎ 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY) 4. Set Time ÌIB'Î + four digits for Hour and Minutes (HHMM) 5. Set the connection according to the length of the codes to be read: Code Length ≤240 Characters ÌRA1aÎ Code Length >240 Characters (not for systems with BC-8000 as Master) ÌRA2dÎ

Set Radio Address

ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. All readers must have different addresses. 7. First STAR-System™ Address ÌRSRÎ Read the code above and the four-digit address of the First STAR-System™ device in the system. 8. Set Last STAR-System™ Address ÌRTTÎ Read the code above and the four-digit address of the Last STAR-System™ device in the system. Whenever the system is composed of a single base station, the first and last base station addresses (steps 7 and 8) must have the same value. NOTE 9. Exit and Save Configuration Ì$-?Î END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

BC-8060 STAR-SYSTEM™ NETWORK SETUP

When the BC-8060 cradle model is used in an RS-485 network, it must be initially configured. To do this using configuration barcodes, follow the procedure below using any PowerScan® M8300 reader. 1. Set BC-8060 Address Ì$+RF4Î + four digits for the BC-8060 Address (from 0000 to 1999). All cradles used in the network must have different addresses. 2. Exit and Save configuration Ì$-?Î 3. Read the Bind code to pair the PowerScan® M8300 to the BC-8060 cradle for configuration. Bind Ì$+RN0$-IÎ The green LED on the PowerScan® M8300 will blink; the reader is ready to be inserted into the cradle. 4. Firmly insert the reader into the BC-8060 cradle within 10 seconds, a beep will be emitted, signaling that the BC-8060 cradle has been paired to the PowerScan® M8300, and the green LED on the reader will go off. green LED

5. Read the BC-8060 restore default code:

Restore BC-8060 Default Ì$+RX0$-qÎ 6. Read the desired Enable Network code. Enable RS-485 Master Ì$+RZ2$-ÇÎ Enable RS-485 Slave Ì$+RZ1$-~Î END of procedure. For Host Master Network Layouts (see par. 3.2), The network configuration parameters can be changed through STAR-Link™ software running on the PC. Star-Link™ software can be downloaded for free from the web site: www.scanning.datalogic.com. For BC-8060 Master Network Layouts (see par. 3.2), The network configuration parameters can be changed either through the Datalogic Aladdin™ configuration software running on the PC or by reading the barcode selections in the Network section of this manual starting on page 64. If using configuration barcodes, it is advised to completely configure the cradles before reconfiguring the PowerScan® M8300 reader (see below). After completing the BC-8060 cradle configuration and connections in the network, you must reconfigure the PowerScan® M8300 reader using the STAR-System™ procedure in par. 4.6. NOTE

Read the interface selection code for your application.

RS-232 Standard Ì$+CP0$-$Î POS TERMINALS Nixdorf Mode A Ì$+CM2EC0$->Î Fujitsu ICL Mode Ì$+CM1$-ÈÎ Ì$+CM0$-ÃÎ For POS terminal default settings refer to par. 5.15. PEN Ì$+CP6$-BÎ

IBM AT or PS/2 PCs

Ì$+CP500$-aÎ IBM XT PC Notebook Ì$+CP503$-vÎ Ì$+CP505$-ÈÎ IBM SURE1 IBM Terminal 3153 Ì$+CP506$-$Î Ì$+CP504$-}Î IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard). KEY TRANSMISSION MODE make-only keyboard Ì$+CP502$-oÎ make-break keyboard Ì$+CP501$-hÎ KEYBOARD TYPE  advanced keyboard Ì$+FK1$-ÉÎ typewriter keyboard Ì$+FK0$-ÄÎ

The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly

independently from the Keyboard Nationality used. You do not need to make a Keyboard Nationality selection. (default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON. IBM AT - ALT mode Ì$+CP507$-+Î PC Notebook - ALT mode Ì$+CP508$-2Î WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard ASCII Keyboard Ì$+CP510$-gÎ Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ

USB READER CONFIGURATION

The USB interface is available for PowerScan® D8330, BC-80x0 and C-8000 devices and is compatible with the following Operating Systems: Windows 98 (and later) IBM POS for Windows Mac OS 8.0 (and later) 4690 Operating System USB Start-up As with all USB devices, upon connection, the Host performs several checks by communicating with the device. During this phase normal operations are suspended (the LED on the PowerScan® D8330 reader blinks). Two basic conditions must be met before the device is ready, the correct USB driver must be loaded and sufficient power must be supplied to the reader .  For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). Normally the Host supplies sufficient power to the device and the start-up phase ends correctly. (The reader's LED stops blinking and the reader emits the beep OK signal). In rare cases, if the Host does not supply sufficient power to the device, a dialog box will appear on the Host and the device will be blocked (the reader's LED continues blinking). In this case, disconnect the USB device cable at the Host (the reader's LED stops blinking), and then try a different USB port as indicated by the Operating System message. (The device emits the beep OK signal. You can now read codes).  At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web page http://www.scanning.datalogic.com . The device is ready. Successive start-ups will automatically recognize the previously loaded drivers. Connect device to Host Select desired USB interface code (USB-KBD is default) Read test codes. Device is READY Load drivers (if requested) Load drivers (if requested) reader LED blinks reader LED off - BEEP OK First Start-Up 1 2

When configuring USB-COM, the relevant files and drivers must be installed from

the USB Device Installation software, which can be downloaded from the web site http://www.scanning.datalogic.com.

CHANGING DEFAULT SETTINGS

Once your reader is setup, you can change the default parameters to meet your application needs. Refer to the preceding paragraphs for initial configuration in order to set the default values and select the interface for your application. In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group. The first four groups are for Standard Interface parameter configuration for all PowerScan® D8330 series readers and PowerScan® M8300/BC-80X0 Stand-alone configurations only: RS-232 USB WEDGE PEN EMULATION NETWORK PARAMETERS are available only for BC-8060 Network configurations. The following parameter groups are common to all interface applications: DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation. POWER SAVE manages overall current consumption in the reading device. READING PARAMETERS control various operating modes and indicator status functioning. DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions. CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host. It cannot be used with Pen Emulation connections. RADIO PARAMETERS (M8300 series only) allow configuration of radio control parameters. DISPLAY PARAMETERS (some M8300 series models only) allow configuration of reader display parameters.

All PowerScan® D8330 Series readers

+ PowerScan® M8300/BC-80X0 configurations only  BAUD RATE   PARITY   DATA BITS   STOP BITS   HANDSHAKING   ACK/NACK PROTOCOL   FIFO   INTER-CHARACTER DELAY   RX TIMEOUT   SERIAL TRIGGER LOCK  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

Exit and Save Configuration

Ì$+;Î RS-232 Ì$-?Î 42 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î 2400 baud 4800 baud ÌCD4aÎ ÌCD5dÎ  9600 baud 19200 baud ÌCD6gÎ ÌCD7jÎ 38400 baud ÌCD8mÎ PARITY  none ÌCC0SÎ even parity odd parity ÌCC1VÎ ÌCC2YÎ

Exit and Save Configuration

Ì$+;Î RS-232 Ì$-?Î 43 DATA BITS 7 bits ÌCA0OÎ  8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP BITS  1 stop bit ÌCB0QÎ 2 stop bits ÌCB1TÎ HANDSHAKING  disable ÌCE0WÎ hardware (RTS/CTS) software (XON/XOFF) ÌCE1ZÎ ÌCE2]Î RTS always ON ÌCE3`Î See par. 5.1.1 for details.

Exit and Save Configuration

Ì$+;Î RS-232 Ì$-?Î 44 ACK/NACK PROTOCOL  disable ÌER0sÎ enable ÌER1vÎ See par. 5.1.2 for details, particularly on implementing this parameter with PowerScan® M8300. FIFO disable ÌEC0UÎ  enable ÌEC1XÎ See par. 5.1.3 for details. INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds  delay disabled 

Exit and Save Configuration

Ì$+;Î RS-232 Ì$-?Î 45 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds  rx timeout 5 seconds See par. 5.1.4 for details. SERIAL TRIGGER LOCK  disabled ÌCR0qÎ enable and select characters ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − First Character enables device trigger − Second Character inhibits device trigger until the first character is received again.  

Handshaking, Ack/Nack protocol, FIFO,

Inter-character delay, Rx timeout, Serial trigger lock   USB-KBD Keyboard nationality, FIFO, Inter-character delay, Inter-code delay, USB keyboard speed   USB-IBM No parameter selection required.  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

Exit and Save Configuration

Ì$+;Î USB-COM Ì$-?Î 47 HANDSHAKING  disable ÌCE0WÎ hardware (RTS/CTS) software (XON/XOFF) ÌCE1ZÎ ÌCE2]Î RTS always ON ÌCE3`Î See par. 5.1.1 for details. ACK/NACK PROTOCOL  disable ÌER0sÎ enable ÌER1vÎ See par. 5.1.2 for details, particularly on implementing this parameter with PowerScan® M8300. FIFO disable ÌEC0UÎ  enable ÌEC1XÎ See par. 5.1.3 for details.

Exit and Save Configuration

Ì$+;Î USB-COM Ì$-?Î 48 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds  delay disabled RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds  rx timeout 5 seconds See par. 5.1.4 for details. SERIAL TRIGGER LOCK  disabled ÌCR0qÎ enable and select characters ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − First Character enables device trigger − Second Character inhibits device trigger until the first character is received again.   

Exit and Save Configuration

Ì$+;Î USB-KBD Ì$-?Î 49 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default. Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ2jÎ German Italian ÌFJ3mÎ ÌFJ1gÎ Spanish Swedish ÌFJ6vÎ ÌFJ5sÎ  USA ÌFJ0dÎ

Exit and Save Configuration

Ì$+;Î USB-KBD Ì$-?Î 50 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs. Japanese ÌFJ8|Î Russian (Latin) Russian (Cyrillic) ÌFJ9ÃÎ ÌFJA0Î Hungarian Slovenian, Croatian, Serbian (Latin) ÌFJB3Î ÌFJC6Î Romanian Czech Republic ÌFJD9Î ÌFJE<Î FIFO disable ÌEC0UÎ  enable ÌEC1XÎ See par. 5.1.3 for details.

Exit and Save Configuration

Ì$+;Î USB-KBD Ì$-?Î 51 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds  delay disabled INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds  delay disabled USB KEYBOARD SPEED  Normal ÌUT10cÎ Fast ÌUT01dÎ  

All PowerScan® D8330 Series readers

+ PowerScan® M8300/BC-80X0 configurations only  KEYBOARD NATIONALITY   CAPS LOCK   CAPS LOCK AUTO-RECOGNITION   NUM LOCK   INTER-CHARACTER DELAY   INTER-CODE DELAY   KEYBOARD SETTING   WEDGE CONTROL CHARACTER EMULATION  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE, available at the top of each page.

Exit and Save Configuration

Ì$+;Î WEDGE Ì$-?Î 53 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ2jÎ German Italian ÌFJ3mÎ ÌFJ1gÎ Spanish Swedish ÌFJ6vÎ ÌFJ5sÎ  USA ÌFJ0dÎ

Exit and Save Configuration

Ì$+;Î WEDGE Ì$-?Î 54 The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs. Japanese ÌFJ8|Î Russian (Latin) Russian (Cyrillic) ÌFJ9ÃÎ ÌFJA0Î Hungarian Slovenian, Croatian, Serbian (Latin) ÌFJB3Î ÌFJC6Î Romanian Czech Republic ÌFJD9Î ÌFJE<Î CAPS LOCK  caps lock OFF ÌFE0ZÎ caps lock ON ÌFE1]Î Select the appropriate code to match your keyboard caps lock status. NOTE: Caps lock manual configuration is ignored when Caps Lock Auto-Recognition is enabled. For PC Notebook interface selections, the caps lock status is automatically recognized; therefore this command is not necessary.

Exit and Save Configuration

Ì$+;Î WEDGE Ì$-?Î 55 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ  enable ÌFP1sÎ NUM LOCK toggle num lock ÌFL1kÎ  num lock unchanged ÌFL0hÎ This selection is used together with the Alt Mode interface selection for AT or Notebook PCs. It changes the way the Alt Mode procedure is executed; therefore it should be set as follows: • if your keyboard Num Lock is normally on • if your keyboard Num Lock is use num lock unchanged normally off use toggle num lock In this way the device will execute the Alt Mode procedure correctly for your application. INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds  delay disabled 

Exit and Save Configuration

Ì$+;Î WEDGE Ì$-?Î 56 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds  delay disabled KEYBOARD SETTING ALPHANUMERIC KEYBOARD SETTING The device (reader or cradle) can be used with terminals or PCs with various keyboard types and nationalities through a simple keyboard setting procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Keyboard setting consists of communicating to the device how to send data corresponding to the keyboard used in the application. The keys must be set in a specific order. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys. If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Example: Each pressed and released key must generate an acoustic signal on the device; otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the device emits 2 beeps. NOTE: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". setting the alphanumeric keyboard ÌFB0TÎ Read the code above. Press the keys shown in the following table according to their numerical order.  

Some ASCII characters may be missing as this depends on the type of keyboard: these are

generally particular characters relative to the various national symbologies. In this case: • The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with keys not used, or substituted with each other. • characters can be substituted with other single symbols (e.g. "SPACE") even if not included in the barcode set used. • characters can be substituted with others corresponding to your keyboard. The device signals the end of the procedure with 2 beeps indicating the keys have been registered. 01 : Shift 02 : Alt 03 : Ctrl 04 : Backspace 05 : SPACE 28 : 7 51 : N 06 : ! 29 : 8 52 : O 07 : " 30 : 9 53 : P 08 : # 31 : : 54 : Q 09 : $ 32 : ; 55 : R 10 : % 33 : < 56 : S 11 : & 34 : = 57 : T 12 : ' 35 : > 58 : U 13 : ( 36 : ? 59 : V 14 : ) 37 : @ 60 : W 15 : * 38 : A 61 : X 16 : + 39 : B 62 : Y 17 : , 40 : C 63 : Z 18 : - 41 : D 64 : [ 19 : . 42 : E 65 : \ 20 : / 43 : F 66 : ] 21 : 0 44 : G 67 : ^ 22 : 1 45 : H 68 : _ (underscore) 23 : 2 46 : I 69 : ` 24 : 3 47 : J 70 : { 25 : 4 48 : K 71 : | 26 : 5 49 : L 72 : } 27 : 6 50 : M 73 : ~ 74 : DEL Do not place the reader onto the BC-80X0 cradle during this procedure. Otherwise, the battery charging will occur modifying the LEDs functioning. CAUTION

Exit and Save Configuration

Ì$+;Î WEDGE Ì$-?Î 58 CONTROL CHARACTER EMULATION  Ctrl + Shift + Key ÌFO0nÎ Ctrl + Key ÌFO1qÎ

All PowerScan® D8330 Series readers

+ PowerScan® M8300/BC-80X0 configurations only  OPERATING MODE   MINIMUM OUTPUT PULSE   CONVERSION TO CODE 39   OVERFLOW   OUTPUT LEVEL   IDLE LEVEL   INTER-BLOCK DELAY  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Default value 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

The operating mode parameters are complete commands and do not require reading the

Enter and Exit configuration codes. OPERATING MODE  interpret mode Ì$]8Î Interprets commands without sending them to the decoder. transparent mode Ì$[4Î Sends commands to the decoder without interpreting them.

Exit and Save Configuration

Ì$+;Î PEN EMULATION Ì$-?Î 61 MINIMUM OUTPUT PULSE 200 µs low resolution code emulation high resolution code emulation ÌDG0\Î 400 µs  600 µs ÌDG1_Î ÌDG2bÎ 800 µs 1 ms ÌDG3eÎ ÌDG4hÎ 1.2 ms ÌDG5kÎ See par. 5.2.1 for details.

Exit and Save Configuration

Ì$+;Î PEN EMULATION Ì$-?Î 62 CONVERSION TO CODE 39 (D8330 SERIES ONLY)  disable conversion to Code 39 ÌDA0PÎ Transmits codes in their original format. enable conversion to Code 39 ÌDA1SÎ Converts codes read into Code 39 format. See par. 5.2.2 for details. CONVERSION TO CODE 39 AND CODE 128 (M8300 SERIES ONLY)  enable conversion to Code 39 ÌDA1SÎ Converts codes read into Code 39 format. enable conversion to Code 128 ÌDA0PÎ Converts codes read into Code 128 format. See par. 5.2.2 for details. OVERFLOW narrow ÌDH0^Î  medium wide ÌDH1aÎ ÌDH2dÎ See par. 5.2.3 for details.

Exit and Save Configuration

Ì$+;Î PEN EMULATION Ì$-?Î 63 OUTPUT LEVEL  normal ÌDD0VÎ (white = logic level 0) inverted ÌDD1YÎ (white = logic level 1) See par. 5.2.4 for details. IDLE LEVEL  normal ÌDE0XÎ (black level) inverted ÌDE1[Î (white level) See par. 5.2.4 for details. INTER-BLOCK DELAY delay between character blocks transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds  delay disabled See par. 5.2.5 for details. 

BC-8060 model configurations only

 RS-485 NETWORK   NETWORK BAUD RATE   SLAVE ADDRESS RANGE   NETWORK WARNING MESSAGE   RECEPTION WARNING MESSAGE   MASTER CRADLE HEADER   MASTER CRADLE TERMINATOR  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups. 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

Exit and Save Configuration

Ì$+;Î NETWORK PARAMETERS Ì$-?Î 65 RS-485 NETWORK  disable RS-485 network ÌRZ0)Î enable RS-485 slave enable RS-485 master ÌRZ1,Î ÌRZ2/Î See par. 3.2 for details. If a BC-8060 cradle is errantly configured as a Slave but not connected to a network, it may not be able to receive further commands from the reader. In this case it can be reconfigured by executing the bind procedure, which returns the cradle to Stand-alone configuration. NOTE NETWORK BAUD RATE 9600 ÌJE0^Î 19200  38400 ÌJE1aÎ ÌJE2dÎ

Exit and Save Configuration

Ì$+;Î NETWORK PARAMETERS Ì$-?Î 66 SLAVE ADDRESS RANGE First Address ÌJB(Î Read the code above and the four-digit address of the First Slave device in the system. Last Address ÌJC*Î Read the code above and the four-digit address of the Last Slave device in the system. See par. 5.3.1 for details. NETWORK WARNING MESSAGE  network warning message not transmitted ÌJG0bÎ network warning message transmitted ÌJG1eÎ See par. 5.3.2 for details. RECEPTION WARNING MESSAGE reception warning message not transmitted ÌJH0dÎ  reception warning message transmitted ÌJH1gÎ See par. 5.3.3 for details.  

Exit and Save Configuration

Ì$+;Î NETWORK PARAMETERS Ì$-?Î 67 MASTER CRADLE HEADER  no header ÌJA00/Î one character header two character header  ÌJA013Î  ÌJA027Î three character header four character header  ÌJA03;Î  ÌJA04?Î five character header six character header  ÌJA05CÎ  ÌJA06GÎ seven character header eight character header  ÌJA07KÎ  ÌJA08OÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range: 00-FE Example : four character header + 41 + 42 + 43 + 44 = Header ABCD For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.

Exit and Save Configuration

Ì$+;Î NETWORK PARAMETERS Ì$-?Î 68 MASTER CRADLE TERMINATOR  no terminator ÌJA102Î one character terminator two character terminator  ÌJA116Î  ÌJA12:Î three character terminator four character terminator  ÌJA13>Î  ÌJA14BÎ five character terminator six character terminator  ÌJA15FÎ  ÌJA16JÎ seven character terminator eight character terminator  ÌJA17NÎ  ÌJA18RÎ After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Valid characters are in the range: 00-FE Example: two character terminator + 0D + 0A = Terminator CR LF For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.

NOT FOR PEN INTERFACES

 CODE IDENTIFIER   CUSTOM CODE IDENTIFIER   HEADER   TERMINATOR   SPECIAL KEYS   FIELD ADJUSTMENT   FIELD ADJ. CHARACTER   CODE LENGTH TX   CHARACTER REPLACEMENT   ADDRESS STAMPING   ADDRESS DELIMITER   TIME STAMPING   TIME DELIMITER  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE, available at the top of each page.

CODE IDENTIFIER TABLE

CODE AIM STANDARD DATALOGIC STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 normal 5 bars ] S y O 2/5 matrix 3 bars ] X y Q EAN 8 ] E 4 A EAN 13 ] E 0 B UPC A ] X y C UPC E ] X y D EAN 8 with 2 ADD ON ] E 5 J EAN 8 with 5 ADD ON ] E 6 K EAN 13 with 2 ADD ON ] E 1 L EAN 13 with 5 ADD ON ] E 2 M UPC A with 2 ADD ON ] X y F UPC A with 5 ADD ON ] X y G UPC E with 2 ADD ON ] X y H UPC E with 5 ADD ON ] X y I Code 39 ] A y V Code 39 Full ASCII ] A y W CODABAR ] F y R ABC CODABAR ] X y S Code 128 ] C y T EAN 128 ] C y k ISBT 128 ] C4 f Code 93 ] G y U CIP/39 ] X y Y CIP/HR ] X y e Code 32 ] X y X MSI ] M y Z Code 11 ] H y b Code 16K ] K 0 p Code 49 ] T y q GS1 DataBar™ Expanded Linear and Stacked ] e 0 t GS1 DataBar Limited ] e 0 v GS1 DataBar 14 Linear and Stacked ] e 0 u • AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.). • When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). • The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character. • Write in the Custom character identifiers in the table above for your records.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 71 CODE IDENTIFIER  disable ÌEB0SÎ Datalogic standard AIM standard ÌEB1VÎ ÌEB2YÎ custom ÌEB3\Î CUSTOM CODE IDENTIFIER define custom code identifier(s) ÌEH/Î  Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page).  Select the code type from the code table in Appendix B for the identifier you want to change.  You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step : valid characters are in the range 00-FD. Example : To define Code 39 Code Identifier = @ define custom code identifier(s) Code 39 Read ÌEH/Î + ÌVWÎ + 40 + FF 

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 72 HEADER no header ÌEA00*Î one character header two character header  ÌEA01.Î  ÌEA022Î three character header four character header  ÌEA036Î  ÌEA04:Î five character header six character header  ÌEA05>Î  ÌEA06BÎ seven character header eight character header  ÌEA07FÎ  ÌEA08JÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 74. Example : four character header + 41 + 42 + 43 + 44 = Header ABCD For more details see par. 5.4.1 and par. 5.4.2.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 73 TERMINATOR no terminator ÌEA10-Î one character terminator two character terminator  ÌEA111Î  ÌEA125Î three character terminator four character terminator  ÌEA139Î  ÌEA14=Î five character terminator six character terminator  ÌEA15AÎ  ÌEA16EÎ seven character terminator eight character terminator  ÌEA17IÎ  ÌEA18MÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 74. Example: two character terminator + 0D + 0A = Terminator CR LF For more details see par. 5.4.1 and par. 5.4.2.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 74 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces It is necessary to define each Special Key by following the procedure given in par. 5.4.2. NOTE Select one or more of the following Special Keys according to your needs. Special Key 1 Ì9CÄÎ Special Key 2 Special Key 3 Ì9DÆÎ Ì9EÈÎ Special Key 4 Special Key 5 Ì9FÊÎ ÌA0bÎ

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 75 FIELD ADJUSTMENT  disable field adjustment ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define  Read the enable field adjustment code: the field adjustment: enable field adjustment  ÌEF+Î  Select the code type from the Code Identifier Table B in Appendix .  Select the type of adjustment to perform: right addition Ì01Î left addition right deletion Ì12Î Ì23Î left deletion Ì34Î  Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: • Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter. • If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0. • You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families. Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment Code 39 right addition Read ÌEF+Î + ÌVWÎ + Ì01Î + 04

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 76 FIELD ADJUSTMENT CHARACTER  Read the field adjustment character code: field adjustment character  ÌEG-Î  Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 74. To define the field adjustment character = A: Example: Read field adjustment character + 41 CODE LENGTH TX  code length not transmitted ÌEE0YÎ code length transmitted in variable-digit format ÌEE1\Î code length transmitted in fixed 4-digit format ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 77 CHARACTER REPLACEMENT  disable character replacement ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:  Read one of the following character replacement codes: first character replacement  ÌEO1pÎ second character replacement  ÌEO2sÎ third character replacement  ÌEO3vÎ  From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families.  From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE), which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 74.  From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE), which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 74. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 78 Example : The following strings define: 1. First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character. 2. Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character. first character replacement Code 39 ASCII characters corresponding to the HEX value for character 0 ASCII characters corresponding to the HEX value for character 1 ÌEO1pÎ + ÌVWÎ + 30 + 31 For Code 39 codes containing the string "0123", the contents transmitted will be "1123". second character replacement Code 39 ASCII characters corresponding to the HEX value for character A ASCII characters corresponding to the HEX value for character B ÌEO2sÎ + ÌVWÎ + 41 + 42 For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 79 ADDRESS STAMPING (M8300 SERIES ONLY)  disable reader address stamping ÌRU0ÊÎ  disable cradle address stamping enable reader address stamping ÌRW0#Î ÌRU1"Î enable cradle address stamping ÌRW1&Î See par. 5.4.3 for details. ADDRESS DELIMITER (M8300 SERIES ONLY)  disable reader address delimiter ÌRV0!Î  disable cradle address delimiter enable reader address delimiter and select characters ÌRY0'Î  ÌRV1$Î enable cradle address delimiter and select characters  ÌRY1*Î Read 2 HEX characters in the range 00-FE. Read 2 HEX characters in the range 00-FE. See par. 5.4.4 for details.

Exit and Save Configuration

Ì$+;Î DATA FORMAT Ì$-?Î 80 TIME STAMPING (M8300 SERIES ONLY)  disable ÌIL0kÎ hour/minutes/seconds month/day/year hour/minutes/seconds day/month/year ÌIL1nÎ hour/minutes/seconds month/day/year ÌIL3tÎ ÌIL4wÎ day/month/year ÌIL5zÎ See par. 5.4.5 for details. TIME STAMPING DELIMITER (M8300 SERIES ONLY) enable  disable select delimiter  ÌIM1pÎ Read 2 HEX characters in the range 00-FE. See par. 5.4.6 for details.

ENTER SLEEP TIMEOUT

 1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

Exit and Save Configuration

Ì$+;Î POWER SAVE Ì$-?Î 82 SLEEP STATE  disable ÌBQ0nÎ enable ÌBQ1qÎ See par. 5.5.1 for details. For M8300 series readers, sleep state is entered immediately after reading a code and is not configurable. ENTER SLEEP TIMEOUT enter sleep timeout ÌBR@Î Read 2 numbers in the range 00-99: 00 = Enter Sleep state immediately 01-99 = corresponds to a max. 9.9 sec. delay before entering the Sleep state.  enter sleep timeout = 0.6 sec. See par. 5.5.2 for details. 

READS PER CYCLE

  SAFETY TIME   BEEPER INTENSITY   BEEPER TONE   BEEPER TYPE   BEEPER LENGTH   GOOD READ SPOT DURATION   AIMING SYSTEM   CRADLE BEEPER INTENSITY  1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Read the code and follow the procedure given  = Default value 3. Read the Exit and Save Configuration code ONCE, available at the top of each page.

Exit and Save Configuration

Ì$+;Î READING PARAMETERS Ì$-?Î 84 TRIGGER TYPE  hardware trigger ÌBK1eÎ Restores TRIGGER MODE software trigger always on ÌBK0bÎ Enables FLASH MODE ÌBK3kÎ TRIGGER SIGNAL  trigger active level ÌBA0NÎ trigger active pulse ÌBA1QÎ See par. 5.6.1 for details. TRIGGER CLICK  disable ÌBc0+Î enable ÌBc1.Î See par. 5.6.2 for details.

Exit and Save Configuration

Ì$+;Î READING PARAMETERS Ì$-?Î 85 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically.  trigger-off timeout disabled See par. 5.6.3 for details. FLASH MODE "FLASH" ON duration ÌBB0PÎ "FLASH" OFF duration ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds.  Flash-ON = 1 sec. Flash-OFF = 0.6 sec READS PER CYCLE  one read per cycle ÌBC0RÎ multiple reads per cycle ÌBC1UÎ See par. 5.6.4 for details.   

Exit and Save Configuration

Ì$+;Î READING PARAMETERS Ì$-?Î 86 SAFETY TIME safety time ÌBE&Î Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code.  safety time = 0.5 sec See par. 5.6.5 for details. BEEPER INTENSITY * very low intensity ÌBG0ZÎ low intensity medium intensity ÌBG1]Î ÌBG2`Î  high intensity ÌBG3cÎ * This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 7.6. 

Exit and Save Configuration

Ì$+;Î READING PARAMETERS Ì$-?Î 87 BEEPER TONE tone 1 ÌBH0\Î  tone 2 tone 3 ÌBH1_Î ÌBH2bÎ tone 4 ÌBH3eÎ BEEPER TYPE  monotone ÌBJ0`Î bitonal ÌBJ1cÎ BEEPER LENGTH long ÌBI0^Î  short ÌBI1aÎ

Exit and Save Configuration

Ì$+;Î READING PARAMETERS Ì$-?Î 88 GOOD READ SPOT DURATION disable ÌBV0xÎ short  medium ÌBV1{Î ÌBV2~Î long ÌBV3ÅÎ AIMING SYSTEM  disabled ÌBj09Î enabled ÌBj1<Î CRADLE BEEPER INTENSITY disable ÌJI0fÎ low intensity medium intensity ÌJI1iÎ ÌJI2lÎ  high intensity ÌJI3oÎ

Before changing these parameter values read the descriptions in

par. 5.7. CAUTION 1. Read the Enter Configuration code ONCE , available at the top of each page. 2. Read configuration codes from the desired groups.  = Default value 3. Read the Exit and Save Configuration code ONCE , available at the top of each page.

Exit and Save Configuration

Ì$+;Î DECODING PARAMETERS Ì$-?Î 90 INK SPREAD disable ÌAX0{Î  enable ÌAX1~Î See par. 5.7.1 for details. OVERFLOW CONTROL disable ÌAW1|Î  enable ÌAW0yÎ See par. 5.7.2 for details. INTERDIGIT CONTROL disable ÌAV0wÎ  enable ÌAV1zÎ See par. 5.7.3 for details.

Exit and Save Configuration

Ì$+;Î DECODING PARAMETERS Ì$-?Î 91 DECODING SAFETY  one read ÌED0WÎ (decoding safety disabled) two reads three reads ÌED1ZÎ ÌED2]Î four reads ÌED3`Î Required number of good reads before accepting code. PUZZLE SOLVER™  disable ÌAU0uÎ enable ÌAU1xÎ In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it. To read codes using this technology, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly. Conditions: • This parameter is only valid for the following codes: EAN 8 without Add-on EAN 13 without Add-on UPC A without Add-on Code 128 Code 39 • For Code 39, Check digit control is forced. • PuzzleSolver is not valid for ISBT 128 code.

Other Barcode Reader Manuals