EXPORT CONTROL WARNING: This document contains controlled technology or technical data

under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both. Communications Test Set 3500 / 3500A Operation Manual Issue-4

Subject to Export Control, see Cover Page for details.

OPERATION MANUAL COMMUNICATIONS TEST SET 3500 / 3500A PUBLISHED BY Aeroflex COPYRIGHT © Aeroflex 2010 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior permission of the publisher. Reissued Jan 2010 Issue-2 Apr 2010 Issue-3 May 2010 Issue-4 Mar 2011 10200 West York / Wichita, Kansas 67215 U.S.A. / (316) 522-4981 / FAX (316) 524-2623

Subject to Export Control, see Cover Page for details.

Electromagnetic Compatibility: For continued EMC compliance, all external cables must be shielded and three meters or less in length. Nomenclature Statement: In this manual, 3500 / 3500A, Test Set or Unit refers to the 3500 / 3500A Communications Test Set.

Subject to Export Control, see Cover Page for details.

SAFETY FIRST: TO ALL OPERATIONS PERSONNEL REFER ALL SERVICING OF UNIT TO QUALIFIED TECHNICAL PERSONNEL. THIS UNIT CONTAINS NO OPERATOR SERVICEABLE PARTS. WARNING: USING THIS EQUIPMENT IN A MANNER NOT SPECIFIED BY THE ACCOMPANYING DOCUMENTATION MAY IMPAIR THE SAFETY PROTECTION PROVIDED BY THE EQUIPMENT. CASE, COVER OR PANEL REMOVAL Opening the Case Assembly exposes the operator to electrical hazards that can result in electrical shock or equipment damage. Do not operate this Test Set with the Case Assembly open. SAFETY IDENTIFICATION IN TECHNICAL MANUAL This manual uses the following terms to draw attention to possible safety hazards, that may exist when operating or servicing this equipment. CAUTION: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN EQUIPMENT OR PROPERTY DAMAGE (E.G., FIRE). WARNING: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN PERSONAL INJURY OR DEATH. SAFETY SYMBOLS IN MANUALS AND ON UNITS CAUTION: Refer to accompanying documents. (This symbol refers to specific CAUTIONS represented on the unit and clarified in the text.) AC OR DC TERMINAL: Terminal that may supply or be supplied with AC or DC voltage. DC TERMINAL: Terminal that may supply or be supplied with DC voltage. AC TERMINAL: Terminal that may supply or be supplied with AC or alternating voltage. EQUIPMENT GROUNDING PRECAUTION Improper grounding of equipment can result in electrical shock. USE OF PROBES Check the specifications for the maximum voltage, current and power ratings of any connector on the Test Set before connecting it with a probe from a terminal device. Be sure the terminal device performs within these specifications before using it for measurement, to prevent electrical shock or damage to the equipment. POWER CORDS Power cords must not be frayed, broken nor expose bare wiring when operating this equipment. USE RECOMMENDED FUSES ONLY Use only fuses specifically recommended for the equipment at the specified current and voltage ratings. INTERNAL BATTERY This unit contains a Lithium Ion Battery, serviceable only by a qualified technician. CAUTION: SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TO COMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTION AND INTERFERENCE TO COMMUNICATION SERVICES OUT TO A DISTANCE OF SEVERAL MILES. USERS OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTS IN RADIATION OF A SIGNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARY PRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.

Subject to Export Control, see Cover Page for details.

DECLARATION OF CONFORMITY The Declaration of Conformity Certificate included with the Unit should remain with the Unit. Aeroflex recommends the operator reproduce a copy of the Declaration of Conformity Certificate to be stored with the Operation Manual for future reference.

Subject to Export Control, see Cover Page for details.

i SCOPE This Manual contains Instructions for operating the 3500 / 3500A. It is strongly recommended that the Operator be thoroughly familiar with this manual before attempting to operate the equipment. ORGANIZATION The Manual is composed of the following Chapters: CHAPTER 1 - INTRODUCTION Provides an Introduction and a Brief Overview of Functions and Features. Principles of Operation are also included. CHAPTER 2 - OPERATING INSTRUCTIONS Identifies and functionally describes all Controls, Indicators and Connectors. Identifies and explains all Operation Screens and Menus. Provides a Turn-On Procedure and Initial Adjustments. Provides Applications. CHAPTER 3 - OPERATOR MAINTENANCE Identifies and explains Routine Service, Troubleshooting, Maintenance and Storage Procedures. CHAPTER 4 - OPTIONS Identifies and explains the Options available for the 3500 / 3500A.

TABLE OF CONTENTS

ii Subject to Export Control, see Cover Page for details. PARAGRAPH PAGE CHAPTER 1 - INTRODUCTION 1-1 General Information .................................................................................... 1-1 1-1A Scope .................................................................................................... 1-1 1-1B Nomenclature Cross-Reference List .......................................................... 1-1 1-2 Equipment Capabilities and Features ............................................................ 1-2 1-2A Capabilities ............................................................................................ 1-2 1-2B Features ................................................................................................ 1-3 1-3 Equipment Data .......................................................................................... 1-4 1-4 Principles of Operation ................................................................................ 1-15 CHAPTER 2 - OPERATING INSTRUCTIONS 2-1 Operator’s Controls, Indicators and Connectors.............................................. 2-1 2-2 Operation Screens and Menu Configurations .................................................. 2-5 2-2-1 Screen Icons .......................................................................................... 2-6 2-2-2 System Menu .......................................................................................... 2-8 2-2-2A Duplex Test Screen............................................................................. 2-9 2-2-2B Receiver Test Screen .......................................................................... 2-18 2-2-2C Transmitter Test Screen ...................................................................... 2-26 2-2-2D ANT-Cable Test Screen ....................................................................... 2-31 2-2-2E Audio Function Generator Test Screen .................................................. 2-40 2-2-3 Meters Menu .......................................................................................... 2-44 2-2-3A SINAD Meter Screen ........................................................................... 2-45 2-2-3B Distortion Meter Screen ....................................................................... 2-47 2-2-3C AF Counter Screen ............................................................................. 2-49 2-2-3D Audio Level Meter Screen .................................................................... 2-51 2-2-4 Self Test Menu ....................................................................................... 2-53 2-2-4A Self Test Screen ................................................................................. 2-54 2-2-4B Diagnostic Screen............................................................................... 2-55 2-2-4C Calibration Screen .............................................................................. 2-58 2-2-5 Utilities Menu ......................................................................................... 2-59 2-2-5A Annunciator Setup Screen ................................................................... 2-60 2-2-5B Remote Setup Screen .......................................................................... 2-61 2-2-5C Version Screen ................................................................................... 2-66 2-2-5D Date / Time Screen ............................................................................. 2-67 2-2-5E HW Config Setup Screen ..................................................................... 2-68 2-2-5F Options Screen ................................................................................... 2-70 2-2-5G USB Manager Screen .......................................................................... 2-71 2-2-5H Unit Copy Screen ................................................................................ 2-72 2-2-6 Other Meters / Functions ......................................................................... 2-73 2-2-6A DCS Decode Meter ............................................................................. 2-74 2-2-6B DTMF Decode Meter ........................................................................... 2-75 2-2-6C Function Generator ............................................................................. 2-76 2-2-6D Modulation Meter Screen ..................................................................... 2-77 2-2-6E RF Error Meter Screen ........................................................................ 2-79 2-2-6F RF Power Meter Screen ....................................................................... 2-81 2-2-6G RSSI Meter Screen ............................................................................. 2-83 2-2-7 Other Functions ...................................................................................... 2-85 2-2-7A Recall Configuration Screen ................................................................ 2-85 2-2-7B Save Configuration Screen .................................................................. 2-86 2-3 Preventive Maintenance Checks and Services ................................................ 2-87 2-3-1 General ................................................................................................. 2-87 2-3-2 Preventive Maintenance Procedures ......................................................... 2-87 2-3-2A Tools, Materials and Equipment Required .............................................. 2-87 2-3-2B Routine Checks .................................................................................. 2-87 2-3-2C Schedule of Checks ............................................................................ 2-87

Subject to Export Control, see Cover Page for details.

iii PARAGRAPH PAGE CHAPTER 2 - OPERATING INSTRUCTIONS (cont) 2-4 Operation Under Usual Conditions ................................................................ 2-88 2-4-1 Turn-On Procedure ................................................................................. 2-88 2-4-2 Screen Warnings and Cautions ................................................................. 2-90 2-5 Operating Procedures .................................................................................. 2-91 2-5-1 Introduction ............................................................................................ 2-91 2-5-2 Typical Vehicle Installation Test ............................................................... 2-92 2-5-3 Advanced Vehicle Installation Testing ....................................................... 2-96 2-5-4 Measuring SWR ...................................................................................... 2-97 2-5-5 Measuring DTF (Distance to Fault) ........................................................... 2-102 2-5-6 Measuring Reverse Power........................................................................ 2-108 2-5-7 Loading Software using USB Memory Device ............................................. 2-112 CHAPTER 3 - MAINTENANCE 3-1 Service Upon Receipt .................................................................................. 3-1 3-1-1 Service Upon Receipt of Material .............................................................. 3-1 3-1-1A Unpacking .......................................................................................... 3-1 3-1-1B Checking Unpacked Equipment ............................................................ 3-1 3-1-2 Preliminary Servicing and Adjustment of Equipment .................................... 3-2 3-2 Troubleshooting .......................................................................................... 3-3 3-3 Maintenance Procedures .............................................................................. 3-7 3-3-1 Battery Recharging ................................................................................. 3-7 3-3-2 Battery Replacement ............................................................................... 3-8 3-3-3 Fuse Replacement .................................................................................. 3-11 3-3-4 Handle Replacement ............................................................................... 3-14 3-3-5 Bumper Replacement .............................................................................. 3-16 3-4 Preparation for Storage or Shipment ............................................................. 3-17 3-4A Packaging ............................................................................................ 3-17 3-4B Environment ........................................................................................... 3-17 CHAPTER 4 - OPTIONS 4-1 General ..................................................................................................... 4-1 4-2 Installing Options ........................................................................................ 4-2 4-3 Spectrum Analyzer Option (35000010) ........................................................... 4-3 4-3-1 Spectrum Analyzer Screen ....................................................................... 4-4 4-3-2 Spectrum Analyzer Screen Features and Functions .................................... 4-5 4-4 Oscilloscope Option (35000001) ................................................................... 4-15 4-4-1 Oscilloscope Screen ............................................................................... 4-15 4-4-2 Oscilloscope Screen Features and Functions ............................................. 4-16 4-5 Tracking Generator Option (35000070) .......................................................... 4-23 4-5-1 Tracking Generator Screen ...................................................................... 4-23 4-5-2 Tracking Generator Screen Features and Functions .................................... 4-24 4-6 P25 Option (35000100) ................................................................................ 4-31 4-6-1 P25 Mini-Meter ....................................................................................... 4-31 4-6-2 P25 Mini-Meter Features and Functions ..................................................... 4-32 4-6-3 Digital Receive (P25) Screen Features and Functions ................................. 4-33 4-7 DMR Option (35000200) ............................................................................... 4-35 4-7-1 DMR Mini-Meter ...................................................................................... 4-35 4-7-2 DMR Mini-Meter Features and Functions ................................................... 4-36 4-7-3 Digital Receive (DMR) Screen Features and Functions ................................ 4-37 4-8 NXDN Option (35000400) ............................................................................. 4-41 4-8-1 NXDN Mini-Meter .................................................................................... 4-41 4-8-2 NXDN Mini-Meter Features and Functions .................................................. 4-42 4-8-3 Digital Receive (NXDN) Screen Features and Functions .............................. 4-43

Subject to Export Control, see Cover Page for details.

PARAGRAPH PAGE CHAPTER 4 - OPTIONS (cont) 4-9 dPMR Option (35000300) ............................................................................. 4-45 4-9-1 dPMR Mini-Meter .................................................................................... 4-45 4-9-2 dPMR Mini-Meter Features and Functions .................................................. 4-46 4-9-3 Digital Receive (dPMR) Screen Features and Functions .............................. 4-47 4-10 ARIBT98 Option (35000500) ......................................................................... 4-49 4-10-1 ARIBT98 Mini-Meter ................................................................................ 4-49 4-10-2 ARIBT98 Mini-Meter Features and Functions .............................................. 4-50 4-10-3 Digital Receive (ARIBT98) Screen Features and Functions .......................... 4-51 4-11 Scripting Option (35000060) ......................................................................... 4-53 4-11-1 Scripts Screen ........................................................................................ 4-53 4-11-2 Scripts Screen Features and Functions ..................................................... 4-54 4-11-3 Transfer Scripts to the 3500 / 3500A ......................................................... 4-55 4-11-4 Copy Scripts with Unit Copy Screen .......................................................... 4-57 4-11-5 General Scripting Commands ................................................................... 4-58 4-11-6 Scripting Flowcharts................................................................................ 4-59 APPENDICES A Connector Pin-Out Tables ............................................................................ A-1 A-1 I/O Connectors ....................................................................................... A-1 A-2 AUDIO Connector Pin-Out Table ............................................................... A-3 A-3 REMOTE Connector Pin-Out Table ............................................................ A-5 B Abbreviations ............................................................................................ B-1 C Remote Operation ....................................................................................... C-1 INDEX

LIST OF ILLUSTRATIONS / TABLES

Subject to Export Control, see Cover Page for details. v LIST OF ILLUSTRATIONS TITLE PAGE Controls, Connectors and Indicators 2-1 Comm Breakout Box Connectors 2-4 Menu / Screen Hierarchy 2-5 LIST OF TABLES TITLE PAGE 3500 I/O Connectors A-1 3500A I/O Connectors A-2 3500 AUDIO Connector Pin-Out Table A-3 3500A AUDIO Connector Pin-Out Table A-4 3500 REMOTE Connector Pin-Out Table A-5 3500A REMOTE Connector Pin-Out Table A-6

SERVICE UPON RECEIPT OF MATERIAL

Subject to Export Control, see Cover Page for details. vii Unpacking Special-design packing material inside this shipping carton provides maximum protection for the 3500 / 3500A. Avoid damaging the carton and packing material during equipment unpacking. Use the following steps for unpacking the 3500 / 3500A. ● Cut and remove the sealing tape on the carton top and open the carton. ● Grasp the 3500 / 3500A transit case firmly, while restraining the shipping carton, and lift the equipment and packing material vertically and place the 3500 / 3500A transit case and end cap packing on a suitable flat, clean and dry surface. ● Remove the protective plastic bag from the 3500 / 3500A transit case. Place protective plastic bag and end cap packing material inside shipping carton. Store the shipping carton for future use should the 3500 /3500A need to be returned. Checking Unpacked Equipment ● Inspect the equipment for damage incurred during shipment. If the equipment has been damaged, report the damage to Aeroflex. ● Check the equipment against the packing slip to see if the shipment is complete. Report all discrepancies to Aeroflex.

Subject to Export Control, see Cover Page for details.

Checking Unpacked Equipment (cont) STANDARD ITEMS DESCRIPTION PART NUMBER QTY MODEL 3500 Communications Test Set 1 3500 ONLY 3500A Communications Test Set 1 3500A ONLY Adapter (BNC-F to TNC-M) 23758 (2200-0410-700) 5 3500 / 3500A Antenna (BNC) (50 MHz) 9149 (1201-7617-001) 1 3500A ONLY Antenna (BNC) (150 MHz) 9145 (1201-7616-801) 1 3500A ONLY Antenna (BNC) (450 MHz) 9147 (1201-7616-901) 1 3500A ONLY Antenna (BNC) (800 MHz) 9143 (1201-7616-001) 1 3500A ONLY Cable (BNC) (M-M) (48 in) 62368 (6041-4284-400) 2 3500 / 3500A Cable (TNC) (M-M) (48 in) 62398 (6041-5680-800) 1 3500 / 3500A Case, Accessory 5763 (1000-6200-800) 1 3500 ONLY Case, Accessory 5762 (1000-6200-700) 1 3500A ONLY Case, Soft-Sided Carrying 10191 (1412-0006-006) 1 3500 ONLY Case, Soft-Sided Carrying 10192 (1412-0006-007) 1 3500A ONLY Comm Breakout Box 64598 (7005-6242-900) 1 3500 / 3500A External DC Power Supply 67374 (7110-6200-200) 1 3500 / 3500A Fuse, Spare (5 A, 32 Vdc, Type F) 56080 (5106-0000-057) 2 3500 / 3500A Handset 64592 (7005-6240-200) 1 3500 ONLY Handset Cable 62403 (6041-6280-000) 1 3500 ONLY Handset 64606 (7005-6244-700) 1 3500A ONLY Manual, Getting Started (Paper) 6107 (1002-6200-8P0) 1 3500 / 3500A Manual, Operation/ICW (CD) 6105 (1002-6200-2C0) 1 3500 / 3500A Power Cable (AC) 62302 (6041-0001-000) 1 3500 ONLY Power Cable (AC) (3-wire leads) 27516 (23424/159) 1 3500A ONLY Power Cable (AC) (Continental Europe) 27480 (23422/007) 1 3500A ONLY Power Cable (AC) (North America) 27478 (23422/005) 1 3500A ONLY Power Cable (AC) (UK) 27477 (23422/002) 1 3500A ONLY Power Cable (DC Cigarette Lighter) 62404 (6041-6281-400) 1 3500 / 3500A Short-Open-Load VSWR Calibrator (TNC) 38245 (2901-0000-054) 1 3500 / 3500A USB Flash Drive (1 GB) 67327 (7110-1100-600) 1 3500A ONLY

Subject to Export Control, see Cover Page for details.

ix Checking Unpacked Equipment (cont) STANDARD ITEMS Adapter (BNC-F to TNC-M) (23758) (2200-0410-700) Antenna (BNC) (50 MHz) (9149) (1201-7617-001) Antenna (BNC) (150 MHz) (9145) (1201-7616-801) Antenna (BNC) (450 MHz) (9147) (1201-7616-901) Antenna (BNC) (800 MHz) (9143) (1201-7616-001) BNC Cable (M-M) (48 in) (62368) (6041-4284-400) TNC Cable (M-M) (48 in) (62398) (6041-5680-800) Accessory Case (3500) (5763) (1000-6200-800)

Subject to Export Control, see Cover Page for details.

Checking Unpacked Equipment (cont) STANDARD ITEMS Accessory Case (3500A) (5762) (1000-6200-700) Soft-Sided Carrying Case (10191) (1412-0006-006) Soft-Sided Carrying Case (10192) (1412-0006-007) Comm Breakout Box (64598) (7005-6242-900) External DC Power Supply (67374) (7110-6200-200) Spare Fuse (5 A, 32 Vdc, Type F) (56080) (5106-0000-057) Handset (3500) (64592) (7005-6240-200) Handset Cable (3500) (62403) (6041-6280-000)

Subject to Export Control, see Cover Page for details.

xi Checking Unpacked Equipment (cont) STANDARD ITEMS Handset (3500A) (64606) (7005-6244-700) Getting Started Manual (6107) (1002-6200-8P0) Operation / ICW Manual (61105 (1002-6200-2C0) AC Power Cable (62302) (6041-0001-000) Power Cable (AC) (3 wire leads) (27516) (23424/159) Power Cable (AC) (Continental Europe) (27480) (23422/007) Power Cable (AC) (North America) (27478) (23422/005) Power Cable (AC) (UK) (27477) (23422/002)

Subject to Export Control, see Cover Page for details.

Checking Unpacked Equipment (cont) STANDARD ITEMS Power Cable (DC Cigarette Lighter) (62404) (6041-6281-400) VSWR Calibrator (TNC) (38245) (2901-0000-054) USB Flash Drive (1 GB) (67327) (7110-1100-600)

Subject to Export Control, see Cover Page for details.

xiii Checking Unpacked Equipment (cont) OPTIONAL ITEMS (These optional items may be included if ordered) DESCRIPTION PART NUMBER QTY MODEL Antenna (BNC) (50 MHz) 9149 (1201-7617-001) 1 3500 ONLY Antenna (BNC) (150 MHz) 9145 (1201-7616-801) 1 3500 ONLY Antenna (BNC) (450 MHz) 9147 (1201-7616-901) 1 3500 ONLY Antenna (BNC) (800 MHz) 9143 (1201-7616-001) 1 3500 ONLY Attenuator (20 dB / 50 W) Attenuator (20 dB / 50 W) Adapter (N-F to BNC-F) Adapter (N-M to TNC-M) 82559 38240 (2901-0000-049) 23770 (2200-0412-800) 23766 (2200-0412-400) 1 1 1 3500 / 3500A Attenuator (20 dB / 150 W) Attenuator (20 dB / 150 W) Adapter (N-F to BNC-F) Adapter (N-M to BNC-F) 82560 38242 (2901-0000-051) 23770 (2200-0412-800) 20327 (2113-0000-004) 1 1 1 3500 / 3500A Battery, Spare 67076 (7020-0012-500) 1 3500 / 3500A Case, Transit 10242 (1412-6200-500) 1 3500 / 3500A Desk Top Stand 63656 (6500-5681-000) 1 3500 / 3500A Directional Coupler (20 to 200 MHz) Directional Coupler (20 to 200 MHz) Attenuator (10 dB) Adapter (N-M to BNC-F) Cable (BNC) (M-M) (16 in) 63964 47290 (4100-0900-000) 38255 (2901-0401-010) 20327 (2113-0000-004) 62405 (6041-6282-000) 1 1 2 2 3500 / 3500A Flip Cover 63966 (7001-6242-100) 1 3500 / 3500A Maintenance Manual (CD) 6108 (1002-6201-4C0) 1 3500 / 3500A Tripod 67474 (7112-8102-500) 1 3500 / 3500A Tripod and Stand with Dolly Tripod Tripod Stand Dolly 82553 67474 (7112-8102-500) 63659 (6500-5881-100) 6361 (1005-1000-000) 1 3500 / 3500A

Subject to Export Control, see Cover Page for details.

Checking Unpacked Equipment (cont) OPTIONAL ITEMS Antenna (BNC) (50 MHz) (9149) (1201-7617-001) Antenna (BNC) (150 MHz) (9145) (1201-7616-801) Antenna (BNC) (450 MHz) (9147) (1201-7616-901) Antenna (BNC) (800 MHz) (9143) (1201-7616-001) 20 dB / 50 W Attenuator (38240) (2901-0000-049) 20 dB / 150 W Attenuator (38242) (2901-0000-051) Adapter (N-M to TNC-M) (23766) (2200-0412-400) Adapter (N-M to BNC-F) (20327) (2113-0000-004) Adapter (N-F to BNC-F) (23770) (2200-0412-800) Spare Battery (67076) (7020-0012-500)

Subject to Export Control, see Cover Page for details.

xv Checking Unpacked Equipment (cont) OPTIONAL ITEMS Transit Case (10242) (1412-6200-500) Directional Coupler (47290) (4100-0900-000) 10 dB Attenuator (38255) (2901-0401-010) BNC Cable (M-M) (16 in) (62405) (6041-6282-000) Desk Top Stand (63656) (6500-6242-100) Flip Cover (63966) (7001-6242-100) Maintenance Manual (6108) (1002-6201-4C0) Tripod (67474) (7112-8102-500)

Subject to Export Control, see Cover Page for details.

Checking Unpacked Equipment (cont) OPTIONAL ITEMS Tripod / Stand / Dolly (67474) (7112-8102-500) / (63659) (6500-5881-100) / (6361) (1005-1000-000)

CHAPTER 1 - INTRODUCTION

Subject to Export Control, see Cover Page for details. 1-1 1-1. GENERAL INFORMATION A. Scope Type of Manual: Operation Manual Equipment Name and Model Number: 3500 / 3500A Communications Test Set Purpose of Equipment: The 3500 / 3500A Communications Test Set is used for testing radios and related equipment. B. Nomenclature Cross-Reference List COMMON NAME OFFICIAL NOMENCLATURE 3500 / 3500A 3500 / 3500A Communications Test Set Test Set or Unit 3500 / 3500A Communications Test Set

Subject to Export Control, see Cover Page for details.

1-2. EQUIPMENT CAPABILITIES AND FEATURES The 3500 / 3500A is a Handheld Communications Test Set for Radio installation testing. The 3500 / 3500A is capable of measuring high power, up to 200 W, as well as fault finding for antennas, power amplifiers and interconnects. The 3500 / 3500A meets the needs of a variety of vehicular radios, as well as commercial radio applications. The 3500 / 3500A is designed for ease of use, portability, reliability and long service life. The 3500 / 3500A may also be used for bench testing in the General Communications environment. Power is derived from an internal battery. For DC input, the DC IN Connector is provided for battery charging, bench operation or servicing. The 3500 / 3500A and supplied accessories are stored in a Soft Carrying Case or a Transit Case. A. Capabilities Capabilities  RF Receiver Testing - Up to 1 GHz bandwidth; AM, FM, frequency and level measurements.  RF Generator Testing - Up to 1 GHz bandwidth; AM, FM, 1 kHz / 150 Hz and external modulation sources.  RF Power Meter - 20 W intermittent duty cycle; 200 W with an external attenuator.  VSWR measurements.  Simple operation with few key strokes and textual displays.  Large LCD Display with user adjustable Backlight and Contrast.  Self Test and Diagnostics for internal validation and testing.  Internal Battery allows 6 hours intermittent use, 5 hours continuous use before recharge.  Automatic power shutdown after approximately 5 to 20 minutes (selectable) of non-use when AC power is not connected.  Compact and lightweight enough to allow for one person operation.

Subject to Export Control, see Cover Page for details.

1-3 B. Features Features  System Menu  Duplex Test Screen  Receiver Test Screen  Transmitter Test Screen  ANT-Cable Test Screen  Audio Function Generator Test Screen  Meters Menu  SINAD Meter Screen  Distortion Meter Screen  AF Counter Screen  Audio Level Meter Screen  Self Test Menu  Self Test Screen  Diagnostic Screen  Calibration Screen  Utilities Menu  Annunciator Screen  Remote Screen  Version Screen  Date/Time Screen  HW Config Screen  Options Screen  USB Manager Screen  Unit Copy Screen Optional Features  Spectrum Analyzer Screen  Oscilloscope Screen  Tracking Generator  P25 Test  DMR  NXDN  dPMR  ARIBT98  Scripting

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA NOTE • Where specified resolution exceeds specified accuracy, the specified resolution takes precedence. • Accuracy and resolution stated in percentages are referenced to the measured or selected value. • All RF characteristics are referenced to 50 Ω. • Allow warm-up period of at least 5 minutes. • Received (input) signal modulation bandwidth does not exceed selected receiver IF bandwidth. • Specifications are subject to change without notice. RF GENERATOR PORT INPUT PROTECTION ANT Port: ............................................................................................................. +20 dBm SWR Port: ............................................................................................................ +20 dBm T/R Port: .......................................................................................+44 dBm (Thermal alarm) FREQUENCY Range: ......................................................................................................... 2 to 1000 MHz Accuracy: ............................................................................................... Same as Timebase Resolution: ................................................................................................................. 1 Hz OUTPUT LEVEL RANGE (TNC FEMALE) T/R Connector (dBm / μV): .................................................. -50 to -120 dBm / 707.1 to 0.2 μV ANT Connector (dBm / μV): ................................................. -30 to -90 dBm / 7071.1 to 7.1 μV SWR Connector (dBm / μV): ............................................ -5 to -65 dBm / 125743.3 to 125.7 μV Level Accuracy: ......................................................................................................... ±2 dB ±3 dB (<-100 dBm) Level Resolution: ....................................................................1 dB / 0.1 μV (1 dB Step Size) CONNECTOR VSWR ANT Connector: .......................................................................................................<1.5 : 1 T/R Connector: ...................................................................................................... <1.25 : 1 SWR Connector: ......................................................................................................<1.5 : 1 SSB PHASE NOISE: .......................................................................... -80 dBc/Hz at 20 kHz offset SPURIOUS Harmonics: ............................................................................................................. -30 dBc Non-Harmonics: .................... -40 dBc (>±20 kHz Offset from Carrier) in Band (2 MHz to 1 GHz) RESIDUAL FM: .............................................................................. <60 Hz in 300 Hz to 3 kHz BW RESIDUAL AM: ................................................................................. <5% in 300 Hz to 3 kHz BW

Subject to Export Control, see Cover Page for details.

1-5 1-3. EQUIPMENT DATA (cont) RF GENERATOR MODULATION - FM Modulation Frequency (Rate) - AM and FM: Range: ..................................................................................................... 0 Hz to 20 kHz Resolution: .......................................................................................................... 0.1 Hz Accuracy: ............................................................................................... Timebase ±2 Hz Modulation Waveforms - AM and FM ............................................................ Sine, DCS, DTMF FM Deviation Range: ........................... Off, 0 Hz to 100 kHz (AFGEN1 and AFGEN2 selectable) Total Harmonic Distortion: .............. 3% (1000 Hz Rate, >2 kHz Deviation, 300 Hz to 3 kHz BPF) FM Deviation Resolution: ........................................................................................... 10 Hz FM Deviation Accuracy: .............................. ±10% (2 to 50 kHz deviation, 150 Hz to 5 kHz rate) MIC IN (3500): Microphone Input: ..................................................................................... 1 to 30 mVrms FM Input Frequency Range: ................................................................... 400 Hz to 1.2 kHz FM Input Slope: .................................................. Positive voltage yields positive deviation MIC IN (3500A): Microphone Input: .......................................... 2 to 15 mVrms (8 mVrms nominal) (Range 1) 35 to 350 mVrms (100 mVrms nominal) (Range 2) 2 to 32 mVrms (20 mVrms nominal) (Range 3) FM Input Frequency Range: ...................................................................... 300 Hz to 3 kHz FM Deviation: .................................................................................... Off, 0 Hz to 80 kHz FM Modulation Accuracy: ........................................................... ±20% (300 Hz to 1.2 kHz) ±30% (>1.2 kHz) FM Input Slope: .................................................. Positive voltage yields positive deviation Ext AUDIN Input: Switchable Loads: ................................................................. 150 Ω, 600 Ω, High Z (3500) 150 Ω, 600 Ω, 1 KΩ, High Z (3500A) Input Levels: ............................................................................................. 0.05 to 3 Vrms FM Input Frequency Range: ...................................................................... 300 Hz to 5 kHz FM Input Level Sensitivity: .................................... 1 kHz / 35 mVrms nominal (High Z Load) FM Input Slope: .................................................. Positive voltage yields positive deviation

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA (cont) RF GENERATOR MODULATION - AM Modulation Frequency (Rate) - AM and FM: Range: ..................................................................................................... 0 Hz to 20 kHz Resolution: .......................................................................................................... 0.1 Hz Accuracy: ............................................................................................... Timebase ±2 Hz AM Modulation: Range: ............................................... OFF, 0% to 100% (AFGEN1 and AFGEN2 selectable) Resolution: ............................................................................................................ 0.1% Accuracy: ............................... 10% of setting, 150 Hz to 5 kHz rate, 10% to 90% Modulation Total Harmonic Distortion: ................3% (20% to 90% mod, 1000 Hz rate, 300 Hz to 3 kHz BPF) Ext AUDIN Input: Switchable Loads: ................................................................. 150 Ω, 600 Ω, High Z (3500) 150 Ω, 600 Ω, 1 KΩ, High Z (3500A) Input Levels: ............................................................................................. 0.05 to 3 Vrms AM Input Frequency Range: ...................................................................... 300 Hz to 5 kHz AM Input Level Sensitivity: ........................................ 1% / 35 mVrms nominal (High Z Load) MIC IN (3500): AM Input Frequency Range: ................................................................... 400 Hz to 1.2 kHz MIC IN (3500A): Microphone Input: .......................................... 2 to 15 mVrms (8 mVrms nominal) (Range 1) 35 to 350 mVrms (100 mVrms nominal) (Range 2) 2 to 32 mVrms (20 mVrms nominal) (Range 3) AM Input Frequency Range: ...................................................................... 300 Hz to 3 kHz AM Modulation: .................................................................................. Off, 0 Hz to 80 kHz AM Modulation Accuracy: ........................................................... ±20% (300 Hz to 1.2 kHz) ±30% (>1.2 kHz)

Subject to Export Control, see Cover Page for details.

1-7 1-3. EQUIPMENT DATA (cont) AUDIO GENERATORS (AFGEN1 AND AFGEN2) NOTE If two sources are selected, they are summed together. AFGEN1 and AFGEN2 may be routed to the external AUD Out connection on the handset. Specifications are for each FGEN individually. Frequency Range: ......................................................................................... 30 Hz to 5 kHz 0 to 20 kHz (operational) Frequency Resolution: .............................................................................................. 0.1 Hz Frequency Accuracy: ................................................................................... Timebase ±2 Hz Output Level: Load Impedance: ................................................................................................... 600 Ω Audio Level Out: ....................................................................................... 0 to 1.57 Vrms Resolution: ..................................................................................................... 0.01 Vrms Accuracy: .............................................................................................................. ±10% Distortion: ................................................................. <3% (1 kHz rate, sine 300 Hz to 3 kHz) HANDSET (PROVIDED) OR H-250 HANDSET WITH ADAPTER Frequency: .............................................................................................. 300 Hz to 1.2 kHz Input Level: .................................................................................................. 0.03 to 8 Vrms PTT OPERATION NOTE PTT ON / OFF changes between TRANSMITTER TEST and RECEIVER TEST. PTT ON: ............................................................................................................. Low, GND PTT OFF: ......................................................................................... High, Open with Pullup

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA (cont) RF RECEIVER FREQUENCY RANGE: .......................................................................................... 2 to 1000 MHz ACCURACY: ............................................................................................................... Timebase RESOLUTION: ................................................................................................................... 1 Hz INPUT AMPLITUDE Minimum Input Level (Audio Sensitivity): ANT Connector: ................. -80 dBm typical, 10 dB SINAD / 22.4 μV (-110 dBm with Preamp) T/R Connector: ..................................................... -40 dBm typical, 10 dB SINAD, 2236 μV Useable Input Level Range (Receiver Measurements): ANT Connector: ..................... -60 to -10 dBm (RF Error, Distortion, Modulation, AF Counter) -80 to -10 dBm with Preamp ON -90 to -10 dBm (RSSI) -110 to -10 dBm with Preamp ON Minimum Input Level (Receiver Measurements) T/R Connector: ............................... -20 dBm (RF Error, Distortion, Modulation, AF Counter) -50 dBm (RSSI) Maximum Input Level: ANT Connector: ..................................................... +20 dBm for 10 seconds, Alarm sounds T/R Connector: ......................................................................................... +37 dBm (AM) +43 dBm (FM) NOTE Overtemp Alarm trips if the power is left on too long and the temperature of the Power Termination gets too hot. FM Demod Output (AUD OUT): IF BW: ........................................... 5, 6.25, 8.33, 10, 12.5, 25, 30, 100 and 300 kHz IF BW Audio Filters BW: .................................. C-Wt BP, CCITT BP, NONE, 15 kHz LP, 300 Hz LP, 300 Hz HP, 5 kHz LP, 300 Hz to 5 kHz BP, 300 Hz to 3 kHz BP, 300 Hz to 20 kHz BP and 3 kHz LP Level Sensitivity: ...................................................... (3 Vrms/kHz Dev) / IF BW (kHz) ±15% AM Demod Output (AUD OUT): IF BW: ................................................................... 5, 6.25, 8.33, 10, 12.5, 25 and 30 kHz Audio Filters BW: .................................. C-Wt BP, CCITT BP, NONE, 15 kHz LP, 300 Hz LP, 300 Hz HP, 5 kHz LP, 300 Hz to 5 kHz BP, 300 Hz to 3 kHz BP, 300 Hz to 20 kHz BP and 3 kHz LP Level Sensitivity: ............................................................................ 7 mVrms / %AM ±15% Speaker Output: ........................... 75 dBa minimum at 0.5 m, 600 to 1800 Hz, maximum volume Volume Control: ........................................................................ Level Range, Scale 0 to 100 LO Emissions: ....................................................................................................... >-50 dBc Quieted Channels: ........ 10 frequencies allowed between 2 and 999.999 MHz, quieted by ≤30 dB

Subject to Export Control, see Cover Page for details.

1-9 1-3. EQUIPMENT DATA (cont) DUPLEX NOTE Duplex Test is Receiver and Transmitter Tests simultaneously. Performance parameters are the same as the independent Receiver and Transmitter Test Screens. RF TRANSMITTER TEST METERS RF ERROR METER Meter Operating Range: ........................................................................................ ±200 kHz Resolution: ................................................................................................................. 1 Hz Accuracy: ................................................................................................... Timebase ±2 Hz RSSI METER (RF Power within Receiver IF BW) Display Range / Units: ........................................................ -120 to +43 dBm (10 pW to 20 W) -120 to +53 dBm (10 pW to 200 W) (Ext Atten set to 20 dB) Useable Meter Reading - RF Level Range: ANT Connector: ....................................................................................... -90 to -10 dBm -110 to -10 dBm (Preamp ON) T/R Connector: ........................................................................................ -50 to +43 dBm Resolution: .......................................................................................................... 0.01 dBm Accuracy: ................................................................................................................. ±3 dB RF POWER METER (Broadband RF Power into T/R Connector) Display Range / Units: .................................................................... 0 to +43 dBm (0 to 20 W) 0 to +53 dBm (0 to 200 W) (Ext Atten set to 20 dB) Minimum Input Level (w/ dBm): .................................................................. 0.10 W / +20 dBm Maximum Input Level: ............................................... +43 dBm / 20 W for 10 minutes at +25°C or until Thermal Alarm sounds (whichever occurs first) Alarms: ................................................................ +44 dBm for 5 seconds ON, 5 minutes OFF or until Thermal Alarm sounds (whichever occurs first) Meter Modes: ............................................................................................... Average Power Display Units: .................................................................................... W or dBm (selectable) Resolution: ........................................................................................... 0.01 (W), 0.1 (dBm) Accuracy No External Attenuator: .......................................................... ±1 dB for internal attenuator With External Attenuator: ........................................... ±1 dB ± external attenuator accuracy NOTE When External Attenuator is selected, 20 dB is added to the measurements of 50 or 200 W.

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA (cont) RF POWER METER (Broadband RF Power into T/R Connector) (cont) External 20 dB Attenuator Accuracy 50 W Attenuator: ............................................................................................... ±0.75 dB 150 W Attenuator: ............................................................................................. ±0.50 dB External 20 dB Attenuator Power Rating: 50 W Attenuator - 20 dB: ................................................................. 50 W average at 25°C 150 W Attenuator - 20 dB: ................................ 150 W average for temperatures up to 25°C, linearly de-rated to 125 W at 55°C, horizontal 200 W peak for 30 seconds ON/ 5 minutes OFF at 25°C FM DEVIATION METER Meter Deviation Range: ........................................................................... 500 Hz to ±100 kHz Meter Modes: ........................................................................... Peak+, Peak-, (Peak-Peak)/2 Resolution: ................................................................................................................. 1 Hz Accuracy: ...................................................................... ±10% (500 Hz to 100 kHz Deviation) ±5% (1 to 10 kHz Deviation) 150 Hz and 1 kHz Rate AM MODULATION METER Meter Range: .................................................................................................... 5% to 100% Meter Modes: ........................................................................... Peak+, Peak-, (Peak-Peak)/2 Resolution: ................................................................................................................... 1% Accuracy: ................................ ±5% of reading, 1 kHz rate, 30% to 90% modulation, 3 kHz LPF SWR MEASUREMENT FREQUENCY Range: ......................................................................................................... 2 to 1000 MHz Calibration and Sweep Bandwidth:..................................... 2 to 1000 MHz, 0.1 MHz Resolution SWR READING Display Range: ................................................................................................. 1.00 to 7.00 Resolution: ................................................................................................................. 0.01 Accuracy: .........................................................±10% of SWR readings (calibrated) <300 MHz ±20% of SWR readings (calibrated) >300 MHz DTF READING Test Range: ...................................................................................... 3 to 328 ft (1 to 100 m) Display Range: .................................................................................................. 40 to 400 ft (Range is function of Frequency Span and Cable Velocity Factor and Cable Loss) Accuracy: ................................................................................................................... ±3 ft

Subject to Export Control, see Cover Page for details.

1-11 1-3. EQUIPMENT DATA (cont) AUDIO METERS AUDIO INPUT (EXT AUD IN) (BNC Input on Handset) EXT AUD IN Input : Frequency Range: ....................... 300 Hz to 10 kHz (1 kHz for SINAD and Distortion Meters) Input Level (3500): ................................................................................. 50 to 1.5 mVrms Input Level (3500A): .................................................................................... 0.2 to 5 Vp-p SINAD METER Measurement Sources: ......................................................................... EXT AUD IN, DEMOD Audio Frequency Notch: ............................................................................................. 1 kHz Reading Range: .................................................................................................. 0 to 40 dB Resolution: .............................................................................................................. 0.1 dB Accuracy: .............................................................. ±1.5 dB, reading >8 dB, <40 dB, ±1 Count DISTORTION METER Measurement Sources: ......................................................................... EXT AUD IN, DEMOD Audio Frequency Notch: ............................................................................................. 1 kHz Reading Range: ................................................................................................ 0% to 100% Resolution: ................................................................................................................ 0.1% Accuracy: ..................................................................... ±10%, reading >1%, <20%, ±1 Count AF COUNTER Input Dynamic Range: FM: ........................... 15 Hz to 20 kHz (IF BW set appropriately for received modulation BW) AM: ......................... 100 Hz to 10 kHz (IF BW set appropriately for received modulation BW) Baseband Audio In: ............................................................................ 10 mVp-p to 5 Vp-p Audio Input Range: ...................................................................................... 15 Hz to 20 kHz Ext Audio Input: ................................................................................. 10 mVrms to 1.5 Vrms Resolution: .............................................................................................................. 0.1 Hz Accuracy: ................................................................................................................. ±1 Hz AUDIO FREQUENCY LEVEL METER Measurement Sources: .............................................................................. EXT AUD IN, DVM Frequency Range: ..................................................................................... 200 Hz to <5 kHz Input Level: EXT AUD IN (3500):........................................................................ 10 mVrms to 1.5 Vrms EXT AUD IN (3500A):.............................. 10 mVrms to 3 Vrms (x1), 1 Vrms to 30 Vrms (÷10) DVM (3500): ............................................................................... 1 Vrms to 30 Vrms (÷20) DVM (3500A): ........................................ 10 mVrms to 3 Vrms (x1), 1 Vrms to 30 Vrms (÷20) Display Unit Resolution: .......................... 0.001 V, 0.001 mV, 0.001 dBμV, 0.001 dBm, 0.001 W Accuracy: ............................................................................................... ±5% (EXT AUD IN)

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA (cont) OSCILLOSCOPE (OPTIONAL) Single Input Channels: ............................................................ DVM, Audio In, Internal Demod Input Impedance: DVM Input: ............................................................................................................ 1 MΩ Audio I/O Input: .................................................................... 150 Ω, 600 Ω, High Z (3500) 150 Ω, 600 Ω, 1 KΩ, Divide-by-10, High Z (3500A) Coupling: DVM Input: ........................................................................................... AC, DC and GND Audio I/O Input: ........................................................................................................ AC FM Internal Demod: ................................................................................................... DC AC Internal Demod: ................................................................................................... AC Range: DVM and Audio I/O Output: ................................ 10 mV/Div to 10 V/Div in a 1,2,5 sequence FM Internal Demodulation: ............................ 0.1 kHz/Div to 50 kHz/Div in a 1,2,5 sequence AM Internal Demodulation: ........................................................... 5%, 10%, 20%, 50%/Div Vertical Accuracy: ................................................................ 10% of Full Scale (DC to 5 kHz) Bandwidth: ............................................................................................................... 5 kHz Horizontal Sweep: Range: ...................................................................................... 0.5 ms/Div to 0.1 sec/Div Accuracy: .............................................................................................. 3% of Full Scale Trigger Source: .......................................................................... Auto or Normal (Internal) Trigger Adjustment: .................................................................. Variable on Vertical Scale Markers: ..................................................................................................... Two Markers Displays Vertical Measurement (Voltage, kHz, % Modulation) Displays Delta in Time between Markers SPECTRUM ANALYZER (OPTIONAL) Frequency: Range: ................................................................................................... 2 MHz to 1 GHz Span: ....................................................................... 10 kHz to 5 MHz in a 1,2,5 sequence Windows: ................................................................................. Hanning, Flat Top, Rectangle Vertical Scale: .................................................................................. 2, 5, 10, 15, 20 dB/Div Marker Range: ................................................................ 1 kHz to 5 MHz in a 1,2,5 sequence Marker Offset: ........................................................... ±1 kHz to 0.5 Span in a 1,2,5 sequence Power Bandwidth Accuracy: ........................................... ±3 dB Typical (30 dB Signal to Noise) Noise Floor: ................................................................. ±3 dB Typical (30 dB Signal to Noise)

Subject to Export Control, see Cover Page for details.

1-13 1-3. EQUIPMENT DATA (cont) TIMEBASE STANDARD OSCILLATOR Temperature Stability: .............................................................................. ±0.25 ppm at 25°C ±0.5 ppm over temperature range Aging: ............................................................................................................. 1 ppm / year Warmup Time: ...................................................................................................... 3 minutes ENVIRONMENTAL / PHYSICAL OVERALL DIMENSIONS: ................... 231 mm (9.1 in) (W), 285 mm (11.2 in) (L), 70 mm (2.8 in) (D) WEIGHT: .................................................. 8.5 lbs.; 12 lbs with accessories and soft carrying case TEMPERATURE Storage: ...................................................................................................... -51°C to +71°C NOTE Battery must not be subjected to temperatures below -20°C, nor above +60°C. Operation: ................................................................................................... -20°C to +50°C NOTE Battery is to be charged at 0°C to +45°C. HUMIDITY Storage: ....................................................................................... MIL-PRF-28800F, Class 2 Operation: .................................................................................... MIL-PRF-28800F, Class 2 ALTITUDE Operation: .................................................................................... MIL-PRF-28800F, Class 2 SHOCK Operation: .................................................................................... MIL-PRF-28800F, Class 2 BENCH HANDLING Operation: .................................................................................... MIL-PRF-28800F, Class 2 VIBRATION Operation: .................................................................................... MIL-PRF-28800F, Class 2 COMPLIANCE USE: ...................................................................................................... Pollution Degree 2 EMC: ........................................................................................... MIL-PRF-28800F, Class 2 AC INPUT POWER AC Input Voltage Range: ................................ 100 to 240 VAC, 1.5 A maximum, 47 Hz to 63 Hz AC Input Voltage Fluctuation: ............................................. <10% of the nominal input voltage Transient Overvoltage: .................................................... According to Installation Category II

Subject to Export Control, see Cover Page for details.

1-3. EQUIPMENT DATA (cont) AC-DC CONVERTER Usage Environment: ................................................................ Indoor use, Pollution Degree 2 Operating Temperature: ................................................................................... 0°C to +40°C Storage Temperature: ................................................................................... -20°C to +85°C EMI: ........................................................................ EN55022 Class B, EN61000-3-2 Class D Safety: ......................................... UL 1950, CSA 22.2 No. 234 and No.950, IEC 950/EN 60950 DC INPUT CONNECTOR (DC IN) DC Input Voltage Range: ................................................................................... 11 to 32 Vdc DC Power Input: Maximum: .............................................................................................................. 55 W Nominal:................................................................................................................ 25 W DC Fuse Requirement: ........................................................................... 5 A, 32 Vdc, Type F BATTERY Battery Type: ....................................................................... Lithium Ion (Li Ion) Battery pack NOTE Battery must not be subjected to temperatures below -20°C, nor above +60°C. Operation Time: ............................................................................... 5 hours continuous use Charge Time: .......................................................................................................... 4 hours NOTE Battery is to be charged at 0°C to +45°C. Dead Battery (<10% capacity) is to be charged for 20 minutes before operation on AC Power. STATIC THERMAL CHARACTERISTICS Ambient, Power ON, RF Power OFF: ............................................. <15°C rise after 30 minutes Ambient, Power ON, RF Power ON: .............................................. <25°C rise after 30 minutes

Subject to Export Control, see Cover Page for details.

1-15 1-4. PRINCIPLES OF OPERATION The 3500 contains the following assemblies: LCD T/R KEYPAD RF DIGITIZER POWER SUPPLY BATTERY MULTI- FUNCTION RF SWR ANT REMOTE DC IN AUDIO The Power Supply PCB Assy is responsible for supplying power to the internal modules for operation and for charging the internal batteries. The RF Digitizer PCB Assy converts the baseband signal to a modulated 10.5 MHz Tx IF which is upconverted in the RF Assy to provide an RF Generator output. The Receive signals are down-converted to 13 MHz and demodulated to baseband signals. The Multi-Function PCB Assy includes the processors, FPGA and memory to send data from the RF Digitizer PCB Assy through the Power PC to the ColdFire for display on the LCD Display. Keyboard inputs are processed to provide instructions to the RF Assy. The RF Assy consists of the RF Controller PCB Assy and the RF Converter PCB Assy. The RF Converter PCB Assy converts the 10.5 MHz TX IF to the 2 MHz to 1 GHz RF and from the 2 MHz to 1 GHz receiver input to the 13 MHz RX IF. The RF Converter PCB Assy also contains the VSWR coupler and associated circuitry and the Power Termination. The RF Controller PCB Assy provides the TCXO, LOs and digital circuitry necessary for software control and for tuning and level control.

Subject to Export Control, see Cover Page for details.

1-4. PRINCIPLES OF OPERATION (cont) The 3500A contains the following assemblies: LCD T/R AUDIO I/O RF DIGITIZER POWER SUPPLY BATTERY MULTI- FUNCTION RF SWR ANT REMOTE DC IN KEYPAD AUDIO DVM AUDIO IN AUDIO OUT The Power Supply PCB Assy is responsible for supplying power to the internal modules for operation and for charging the internal batteries. The RF Digitizer PCB Assy converts the baseband signal to a modulated 10.5 MHz Tx IF which is upconverted in the RF Assy to provide an RF Generator output. The Receive signals are down-converted to 13 MHz and demodulated to baseband signals. The Multi-Function PCB Assy includes the processors, FPGA and memory to send data from the RF Digitizer PCB Assy through the Power PC to the ColdFire for display on the LCD Display. Keyboard inputs are processed to provide instructions to the RF Assy. The RF Assy consists of the RF Controller PCB Assy and the RF Converter PCB Assy. The RF Converter PCB Assy converts the 10.5 MHz TX IF to the 2 MHz to 1 GHz RF and from the 2 MHz to 1 GHz receiver input to the 13 MHz RX IF. The RF Converter PCB Assy also contains the VSWR coupler and associated circuitry and the Power Termination. The RF Controller PCB Assy provides the TCXO, LOs and digital circuitry necessary for software control and for tuning and level control. The Audio I/O PCB Assy provides the DVM/Scope, Audio In and Audio Out signals to the 3500A Front Panel.

CHAPTER 2 - OPERATING INSTRUCTIONS

Subject to Export Control, see Cover Page for details. 2-1 062-006b 3500 AUDIO OUT AUDIO IN DVM 1 2 3 4 5 6 7 8 9 0 (3500A) (3500) 14 15 16 17 18 19 10 11 12 13 7 8 9 1 5 3 2 4 6 20 22 21 (3500A ONLY) 2-1. OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS 1 ANT Connector 2 T/R Connector 3 DC IN Connector 4 AUDIO Connector 5 SWR Connector 6 REMOTE Connector 7 Display (LCD) 8 Multi-Function Soft Keys 9 Number Keys 10 CONTRAST / • Key 11 BACKLIGHT / ± Key 12 CHARGE Indicator 13 POWER Key 14 POWER Indicator 15 FAULT Indicator 16  DOWN Key 17  LEFT Key 18  RIGHT Key 19  UP Key 20 DVM Connector 21 AUDIO IN Connector 22 AUDIO OUT Connector Figure 2-1. Controls, Connectors and Indicators

Subject to Export Control, see Cover Page for details.

2-1. OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont) ITEM DESCRIPTION  LEFT Key Used to move the on-screen cursor from one frame to another. Also used to move the on-screen cursor to the next digit to the left in an edit field. NOTE: The on-screen cursor moves in a fixed order. This is to ensure that all frames and fields are accessed in a predictable fashion.  RIGHT Key Used to move the on-screen cursor from one frame to another. Also used to move the on-screen cursor to the next digit to the right in an edit field. NOTE: The on-screen cursor moves in a fixed order. This is to ensure that all frames and fields are accessed in a predictable fashion.  UP Key Used to move the on-screen cursor from one field to another within a frame. Also used to increment an edit field. NOTE: The on-screen cursor moves in a fixed order. This is to ensure that all frames and fields are accessed in a predictable fashion.  DOWN Key Used to move the on-screen cursor from one field to another within a frame. Also used to decrement an edit field. NOTE: The on-screen cursor moves in a fixed order. This is to ensure that all frames and fields are accessed in a predictable fashion. AUDIO Connector Used for connection to the Microphone. AUDIO IN Connector (3500A only) Used to receive external modulation input, and as input for the SINAD and Distortion Meters and AF Counter. AUDIO OUT Connector (3500A only) Used as output for Demod and Function Generators and for Audio In signal output. ANT Connector Used for over-the-air tests. BACKLIGHT / ± Key Used for selecting the Backlight Adjust Mode. The  UP or  DOWN Keys may be used to adjust the Backlight level to one of 25 different settings. Used to change between positive (+) and negative (-) values during data entry. CHARGE Indicator Illuminates when external DC power is applied: GREEN Battery at Full Charge YELLOW Battery is Charging RED Battery Charge Failure CONTRAST / • Key Used for selecting the Contrast Adjust Mode. The  UP or  DOWN Keys may be used to adjust the Contrast level to one of 25 different settings. Used to add a decimal point (•) to values during data entry.

Subject to Export Control, see Cover Page for details.

2-3 2-1. OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont) ITEM DESCRIPTION DC IN Connector Used for operation of the 3500 / 3500A or battery charging. Display (LCD) Used for viewing menus and screens. Soft Key boxes appear at the bottom of the menus/screens. DVM Connector (3500A only) Provides DC coupled input for the Audio Level Meter and the Oscilloscope (Option) functions. FAULT Indicator Illuminates when a fault exists in the 3500 / 3500A: YELLOW Caution Condition exists RED Warning Condition exists Multi-Function Soft Keys Five Soft Keys are provided. The legends are displayed in boxes at the bottom of the Display. Number Keys Used for data entry or to select a numbered item. Alternate key functions are utilized when selecting file names in the Save Screen. POWER Indicator Illuminates when the 3500 / 3500A is powered up. POWER Key Used for powering the 3500 / 3500A ON and OFF. REMOTE Connector (External I/O) Used for communicating with external equipment. SWR Connector Used for measuring the VSWR of Antenna systems. Also used as a transmit signal output. T/R Connector Used for high power direct connection to radio equipment.

Subject to Export Control, see Cover Page for details.

2-1. OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont) Figure 2-2. Comm Breakout Box Connectors CONNECTOR FUNCTION USB HOST Connector Used to connect to external unit. RS-232 Connector Used to connect to RS-232 external unit. ETHERNET Connector Used to connect to an external unit. REMOTE Connector Used for communicate with the 3500 / 3500A.

Subject to Export Control, see Cover Page for details.

2-5 2-2. OPERATION SCREENS AND MENU CONFIGURATIONS SYSTEM *M ENU DISTORTION SINAD AF *COUNTER AUDIO*LEVEL*M ETER UTILITIES *M ENU SELF*TEST *M ENU AUDIO RECEIVER DUPLEX TRANSM ITTER ANT-CABLE *TEST DIAGNOSTIC SELF*TEST CALIBRATION OPTIONS HW*CONFIG USB*M ANAGER REM OTE ANNUNCIATOR VERSION DATE */*TIM E M ETERS*M ENU UNIT*COPY Figure 2-3. Menu / Screen Hierarchy

Subject to Export Control, see Cover Page for details.

2-2-1. SCREEN ICONS The screen icons are displayed at the top left of the test screens. 41 20 29 SCREEN FEATURE FUNCTION PPC CPU Usage Displays the level of PPC usage. When the PPC usage is 20% to 39%, the icon is displayed as vertical bar. When the PPC usage is 40% to 59%, the icon is displayed as two vertical bars. When the PPC usage is 60% to 79%, the icon is displayed as three vertical bars. When the PPC usage is 80% to 100%, the icon is displayed as four vertical bars. The icon blinks when the PPC usage is >90%. NUMBER Internal Temperature Displays the current FPGA temperature in °C. (Example: 41) When the internal temperature is <-20°C or >85°C, a warning message is displayed. Flash Save Status Displays the status of a save operation. When the icon is fully drawn, all settings are currently saved to Flash. Afer editing, the lower right half of the icon disappears until the settings are saved to Flash. Phase Loop Lock (PLL) Displays the status of the Generator and Receiver Synthesizer Lock. Under normal conditions, the icon is displayed as a square. If the Generator becomes unlocked, a warning message is displayed and a triangle shape is displayed (blinking) above the square icon. If the Receiver becomes unlocked, a warning message is displayed and a triangle shape is displayed (blinking) below the square icon. Battery Level Indicator Displays the percentage of the battery life remaining. When the battery level is<20 (on a 0 to 100 scale) the battery level icon blinks.

Subject to Export Control, see Cover Page for details.

2-7 2-2-1. SCREEN ICONS (cont) SCREEN FEATURE FUNCTION NUMBER Battery Temperature Displays the Battery temperature in °C. (Example: 20) If the battery temperature is >53°C a warning message is displayed and the battery level icon blinks. ANT Connector Overload Indicates if the ANT Connector is in overload mode. If the ANT Connector is in overload mode, a warning message is displayed and the lower half of the icon blinks. T/R Connector Overload Indicates if the T/R Connector is in overload mode. If the T/R Connector is in overload mode, a warning message is displayed and the lower half of the icon blinks. SWR Connector Overload Indicates if the SWR Connector is in overload mode. If the SWR Connector is in overload mode, a warning message is displayed and the lower half of the icon blinks. NUMBER RF Temperature Displays the T/R Connector temperature in °C. (Example: 29) The RF temperature increases when more RF power is dissipated. AGC Compression Displays the level of Receiver compression. With no AGC compression the icon is displayed as a box. When AGC is in compression, a message is displayed and the icon is displayed as an hourglass. DVM Overload Displays the DVM Overload status. When conditions are normal the icon is displayed as a triangle. When an overload occurs, a message is displayed, the icon is displayed as a lightening bolt inside a triangle and the icon blinks.

Subject to Export Control, see Cover Page for details.

2-2-2. SYSTEM MENU When the unit is powered ON, the System Menu is displayed, or when the Meters Menu, Self Test Menu or Utilities Menu is displayed, press the F3 “System” Key to access the System Menu: Meters System Selftest Util 1 - DUPLEX TEST 2 - RECEIVER TEST 3 - TRANSMITTER TEST 4 - ANT-CABLE TEST 5 - AUDIO SCREEN FEATURE FUNCTION 1 - DUPLEX TEST Displays the Duplex Test Screen (para 2-2-2A). 2 - RECEIVER TEST Displays the Receiver Test Screen (para 2-2-2B). 3 - TRANSMITTER TEST Displays the Transmitter Test Screen (para 2-2-2C). 4 - ANT-CABLE TEST Displays the ANT-Cable Test Screen (para 2-2-2D). 5 - AUDIO Displays the Audio Test Screen (para 2-2-2E). F2 “Meters” Displays the Meters Menu (para 2-2-3). F3 “System” Displays the System Menu (para 2-2-2). F4 “Selftest” Displays the Self Test Menu (para 2-2-4). F5 “Util” Displays the Utilities Menu (para 2-2-5).

Subject to Export Control, see Cover Page for details.

2-9 A. Duplex Test Screen When the System Menu is displayed, press the 1 Key to access the Duplex Test Screen: Edit Return Hold Setup PTT on DUPLEX TEST Generator Off Receiver More MH z: 40.000000 MH z: 40.000000 Port: T/R Port: T/R Level: -70 dBm Mod: FM 10k Ext Attn dB: 0 AFBW: 0.3k HP Modulator Freq FM Analog Gen 1: On 1000.0 H z 6.25 kH z Gen 2: On 150.0 H z 3.25 kH z MIC: On 6.25 kH z Ext Aud: Off Load: High Z Volume: 100 Squelch: -50 dBm Speaker: Audio In AudOut: Audio In Save Recall 41 20 29 (CTCSS) Modulator Freq/Code FM DCS Gen 1: Off 150.0 H z 3.50 kH z Dcs: Non Inv 023 6.25 kH z MIC: Off 0.00 kH z Ext Aud: Off Load: High Z Modulator FM DTMF Gen 1: Off 150.0 H z 3.50 kH z DTMF: Burst Trig Lo: 6.25 kH z Seq: 0123456789 Hi: 6.25 kH z Mark: 200 ms Space: 200 ms (DCS) (DTMF) SCREEN FEATURE FUNCTION Status (Generator) Displays the status (On / Off) of the Generator. MHz (Generator) Used to select the signal generator frequency. Range: 2.000000 to 1000.000000 MHz in 0.000001 MHz increments Port (Generator) Used to select the signal generator output connector. Select: Ant, T/R or SWR Receiver More Ext Attn dB: 0.0 Preamp: Auto

Subject to Export Control, see Cover Page for details.

A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION Level (Generator) Used to select the signal generator output level. The Generator Output Level Units can be toggled between dBm and μV. Select: Ant -90 to -30 dBm in 1 dB increments T/R -120 to -50 dBm in 1 dB increments SWR -65 to -5 dBm in 1 dB increments Select: Ant 7.07 to 7071.03 μV in 1 dB increments T/R 0.22 to 707.11 μV in 1 dB increments SWR 125.74 to 125743.3 μV in 1 dB increments Ext Attn dB (Generator) Used to select the external attenuation on the output connector. Select: 0 to 30 dB in 1 dB increments MHz (Receiver) Used to select the signal receiver frequency. Range: 2.000000 to 1000.000000 MHz in 0.000001 MHz increments Port (Receiver) Used to select the signal receiver input connector. Select: Ant or T/R Mod (Receiver) Used to select the signal receiver modulation type. Select: AM Modulation Meter changes to AM%. FM Modulation Meter changes to FM DEV. IFBW (field to right of Mod Field) Used to select the IF bandwidth. Select: (for AM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k or 30k (for FM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k, 30k, 100k or 300k AFBW (Receiver) Used to select the bandwidth filter. Select: 0.3k LP, 3k LP, 5k LP, 15k LP, CCITT BP, C-Wt BP, 0.3-3k BP, 0.3-5k BP, 0.3-20k BP, 0.3k HP or None. More Toggles the Receiver Frame to display the Cable Offset and Preamp Fields. Cable Offset (Receiver) Used to select the cable loss. Cable loss is used by the RSSI and Power Meters to display the power level at the UUT. Select: 0 to 30.0 dB in 0.01 dB steps Ext Attn dB (Receiver) Used to select the external attenuation on the input connector. Select: 0.0 to 30.0 dB in 0.1 dB increments Preamp (Receiver) Used to select preamp operation. Select: Auto, On or Off Modulation Type Used to select the modulation type. Select: AM, FM or Off

Subject to Export Control, see Cover Page for details.

2-11 A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION Modulator Used to change functionality of the modulation source fields. Press F1 “ENTER” Key to toggle between Analog (CTCSS), DCS and DTMF modulation source fields. NOTE: The total combined modulation from all sources in each Modulatorframe cannot exceed 100% for AM or 100 kHz for FM. If the modulation level of a selection source is set to a value that would cause the total modulation to exceed the modulation limit, the value of the unselected sources are lowered automatically. Analog (CTCSS) Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments Gen 2 Used to select internal modulation. This setting can be toggled between Gen 2, DCS (Digitally Coded Squelch) and DCS INV (Inverse DCS). Select: On or Off Select: AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments MIC Used to select the external Microphone and the level of modulation for the microphone input. Select: On The external Microphone modulates the test set signal generator. Off Deactivates the external Microphone input. AM 0% to 100% in 0.1% increments FM 0 to 100 kHz in 0.01 kHz increments Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z

Subject to Export Control, see Cover Page for details.

A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION Ext Aud Used to select external modulation. Select: On Permits an external tone generator to modulate the test set signal generator. Off Deactivates the external Audio input. DCS Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments Dcs Used to select the DCS state. Select: AM: Inv (Interted), NonInv (Non-Inverted) or Off DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054, 065, 071, 072, 073, 074, 114, 115, 116, 125, 131, 132, 134, 143, 152, 155, 156, 162, 165, 172, 174, 205, 223, 226, 243, 244, 245, 251, 261, 263, 265, 271, 306, 311, 315, 331, 343, 346, 351, 364, 365, 371, 411, 412, 413, 423, 431, 432, 445, 464, 465, 466, 503, 506, 516, 532, 546, 565, 606, 612, 624, 627, 631, 632, 654, 662, 664, 703, 712, 723, 731, 732, 734, 743 or 754 %Mod 0% to 100% in 0.1% increments Select: FM: Inv (Interted), NonInv (Non-Inverted) or Off DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054, 065, 071, 072, 073, 074, 114, 115, 116, 125, 131, 132, 134, 143, 152, 155, 156, 162, 165, 172, 174, 205, 223, 226, 243, 244, 245, 251, 261, 263, 265, 271, 306, 311, 315, 331, 343, 346, 351, 364, 365, 371, 411, 412, 413, 423, 431, 432, 445, 464, 465, 466, 503, 506, 516, 532, 546, 565, 606, 612, 624, 627, 631, 632, 654, 662, 664, 703, 712, 723, 731, 732, 734, 743 or 754 Dev kHz 0 to 100 kHz in 0.01 kHz increments

Subject to Export Control, see Cover Page for details.

2-13 A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION MIC Used to select the external Microphone and the level of modulation for the microphone input. Select: On The external Microphone modulates the test set signal generator. Off Deactivates the external Microphone input. AM 0% to 100% in 0.1% increments FM 0 to 100 kHz in 0.01 kHz increments Ext Aud Used to select external modulation. Select: On Permits an external tone generator to modulate the test set signal generator. Off Deactivates the external Audio input. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z DTMF Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments Dtmf Used to select the DTMF state. Select: AM: State Burst, Cont (Continuous) or Off %Mod 0% to 100% in 0.1% increments (Lo) 0% to 100% in 0.1% increments (Hi) Seq Up to 12 characters (0 to 9, A, B, C, D) FM: State Burst, Cont (Continuous) or Off Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments 0 to 100 kHz in 0.01 kHz increments Seq Up to 12 characters (0 to 9, A, B, C, D) Mark Used to select the DTMF timing. Select: 100 to 1000 ms in 1 ms increments Space Used to select the DTMF timing. Select: 100 to 1000 ms in 1 ms increments

Subject to Export Control, see Cover Page for details.

A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION Volume Used to select the Handset volume level. Select: 0 to 100 Squelch Used to select the Squelch level for Duplex and Transmitter tests. Select: -150 to 50 dBm in 1 dB increments Squelch operates in conjunction with the Receiver RSSI Meter. When the RSSI Meter is under this threshold, then the speaker audio is silenced. The RSSI Meter does not need to be displayed on the screen for squelch to be operational. Speaker Used to select the Speaker Output. Select: Audio In, Demod or Fgen Aud Out Used to select the Audio Output Connector. Select: Audio In, Demod or Fgen Save Displays the Save Configuration Screen (para 2-2-7B) to store the current state of the test screen in the internal memory. Recall Displays the Recall Configuration Screen (para 2-2-7A) to recall a stored state of the test screen from internal memory. Meters (not shown) Several Meters can be selected to appear on the Duplex Test Screen. Meters are selected in the Duplex Test Setup Screen. F1 “Edit” / “Done” / “Zoom” / “Enter” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Zoom Displays the screen of the field selected. Enter Moves cursor into meter / function on test screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen. Meters save configurations and readings. Control frames save settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Find” Hold Freezes the screen. Resume Restores the screen to active mode. Find Used to scan and find RF signals. F4 “Setup” Displays the Duplex Test Setup Screen.

Subject to Export Control, see Cover Page for details.

2-15 A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION F5 “Ptt on” / “Ptt off” / “Esc” Ptt on Activates MIC. Turns RF Generator ON and turns Demod Audio OFF. Ptt off Deactivates MIC. Turns RF Generator OFF and turns Demod Audio ON. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

A. Duplex Test Screen (cont) When the Duplex Test Screen is displayed, press the F4 “Setup” Key to access the Duplex Test Setup Screen: DUPLEX TEST SETUP Modulation Meter 0 DCS Decode 0 RSSI Meter 0 Audio Level 0 RF Error Meter 0 RF Power Meter 0 SINAD Meter 0 Distortion Meter 0 AF Counter 0 DTMF Decode 0 Edit Return 1 4 7 2 5 8 3 6 9 41 20 29 Mod-FM Dev 16.670 kHz RSSI 0.0 dBm RF Error 0.0 kHz RF Power 0.0 Watts SINAD Audio In 0.0 dB Distortion Audio In 0.0% AF Cntr Audio In 0.0 Hz DTMF Decode 01234 0123456789 DCS Decode State Run Inv 155 Audio Level Audio In 0.000 V

Subject to Export Control, see Cover Page for details.

2-17 A. Duplex Test Screen (cont) SCREEN FEATURE FUNCTION Modulation Meter Used to select the position of the Modulation Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 RSSI Meter Used to select the position of the RSSI Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 RF Error Meter Used to select the position of the RF Error Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 RF Power Meter Used to select the position of the RF Power Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 SINAD Meter Used to select the position of the SINAD Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 Distortion Meter Used to select the position of the Distortion Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 6, 8 or 9 AF Counter Used to select the position of the AF Counter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 DTMF Decode Used to select the position of the DTMF Decode Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 DCS Decode Used to select the position of the DCS Decode Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 Audio Level Used to select the position of the Audio Level Meter on the Duplex Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 Meter Chart Displays the areas of the Duplex Test Screen and a number representing each area (i.e., 3 is top right on the Duplex Test Screen, etc.). F1 “Edit” / “Done” / “Zoom Edit Highlights the selected field to be changed. Done Ends the Field Edit and saves the new setting / value. Zoom Displays the screen of the field selected. F2 “Return” Displays the Duplex Test Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

B. Receiver Test Screen When the System Menu is displayed, press the 2 Key to access the Receiver Test Screen: Edit Return Hold Setup RECEIVER TEST Generator Off MH z: 40.000000 Port: T/R Level: -70 dBm Ext Attn dB: 0 Modulator Freq FM Analog Gen 1: On 1000.0 H z 6.25 kH z Gen 2: On 150.0 H z 3.25 kH z MIC: On 6.25 kH z Ext Aud: Off Load: High Z Volume: 100 Squelch: -50 dBm Speaker: Audio In AudOut: Audio In Save Recall 41 20 29 (CTCSS) Modulator Freq/Code FM DCS Gen 1: Off 150.0 H z 3.50 kH z Dcs: Non Inv 023 6.25 kH z MIC: Off 0.00 kH z Ext Aud: Off Load: High Z Modulator FM DTMF Gen 1: Off 150.0 H z 3.50 kH z DTMF: Burst Trig Lo: 6.25 kH z Seq: 0123456789 Hi: 6.25 kH z Mark: 200 ms Space: 200 ms (DCS) (DTMF) SCREEN FEATURE FUNCTION Status (Generator) Displays the status (On / Off) of the Generator. MHz Used to select the signal generator frequency. Range: 2.000000 to 1000.000000 MHz in 0.000001 MHz increments Port Used to select the signal generator output connector. Select: Ant, T/R or SWR

Subject to Export Control, see Cover Page for details.

2-19 B. Receiver Test Screen (cont) SCREEN FEATURE FUNCTION Level Used to select the signal generator output level. The Generator Output Level Units can be toggled between dBm and μV. Select: Ant -90 to -30 dBm in 1 dB increments T/R -120 to -50 dBm in 1 dB increments SWR -65 to -5 dBm in 1 dB increments Select: Ant 7.07 to 7071.03 μV in 1 dB increments T/R 0.22 to 707.11 μV in 1 dB increments SWR 125.74 to 125743.3 μV in 1 dB increments Ext Attn dB Used to select the external attenuation on the output connector. Select: 0 to 30 dB in 1 dB increments Modulation Type Used to select the modulation type. Select: AM, FM or Off Modulator Used to change functionality of the modulation source fields. Press F1 “ENTER” Key to toggle between Analog (CTCSS), DCS and DTMF modulation source fields. NOTE: The total combined modulation from all sources in each Modulatorframe cannot exceed 100% for AM or 100 kHz for FM. If the modulation level of a selection source is set to a value that would cause the total modulation to exceed the modulation limit, the value of the unselected sources are lowered automatically. Analog (CTCSS) Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments

Subject to Export Control, see Cover Page for details.

B. Receiver Test Screen (cont) SCREEN FEATURE FUNCTION Gen 2 Used to select internal modulation. This setting can be toggled between Gen 2, DCS (Digitally Coded Squelch) and DCS INV (Inverse DCS). Select: On or Off Select: AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments MIC Used to select the external Microphone and the level of modulation for the microphone input. Select: On The external Microphone modulates the test set signal generator. Off Deactivates the external Microphone input. AM 0% to 100% in 0.1% increments FM 0 to 100 kHz in 0.01 kHz increments Ext Aud Used to select external modulation. Select: On Permits an external tone generator to modulate the test set signal generator. Off Deactivates the external Audio input. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z DCS Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments

Subject to Export Control, see Cover Page for details.

2-21 B. Receiver Test Screen (cont) SCREEN FEATURE FUNCTION Dcs Used to select the DCS state. Select: AM: Inv (Interted), NonInv (Non-Inverted) or Off DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054, 065, 071, 072, 073, 074, 114, 115, 116, 125, 131, 132, 134, 143, 152, 155, 156, 162, 165, 172, 174, 205, 223, 226, 243, 244, 245, 251, 261, 263, 265, 271, 306, 311, 315, 331, 343, 346, 351, 364, 365, 371, 411, 412, 413, 423, 431, 432, 445, 464, 465, 466, 503, 506, 516, 532, 546, 565, 606, 612, 624, 627, 631, 632, 654, 662, 664, 703, 712, 723, 731, 732, 734, 743 or 754 %Mod 0% to 100% in 0.1% increments Select: FM: Inv (Interted), NonInv (Non-Inverted) or Off DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054, 065, 071, 072, 073, 074, 114, 115, 116, 125, 131, 132, 134, 143, 152, 155, 156, 162, 165, 172, 174, 205, 223, 226, 243, 244, 245, 251, 261, 263, 265, 271, 306, 311, 315, 331, 343, 346, 351, 364, 365, 371, 411, 412, 413, 423, 431, 432, 445, 464, 465, 466, 503, 506, 516, 532, 546, 565, 606, 612, 624, 627, 631, 632, 654, 662, 664, 703, 712, 723, 731, 732, 734, 743 or 754 Dev kHz 0 to 100 kHz in 0.01 kHz increments MIC Used to select the external Microphone and the level of modulation for the microphone input. Select: On The external Microphone modulates the test set signal generator. Off Deactivates the external Microphone input. AM 0% to 100% in 0.1% increments FM 0 to 100 kHz in 0.01 kHz increments Ext Aud Used to select external modulation. Select: On Permits an external tone generator to modulate the test set signal generator. Off Deactivates the external Audio input. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z

Subject to Export Control, see Cover Page for details.

B. Receiver Test Screen (cont) DTMF Modulation Source Fields Gen 1 Used to select internal modulation. Select: On or Off AM: Freq 0 to 20000 Hz in 1 Hz increments %Mod 0% to 100% in 0.1% increments FM: Freq 0 to 20000 Hz in 1 Hz increments Dev kHz 0 to 100 kHz in 0.01 kHz increments Dtmf Used to select the DTMF state. Select: AM: State Burst, Cont (Continuous) or Off %Mod 0% to 100% in 0.1% increments (Lo) 0% to 100% in 0.1% increments (Hi) Seq Up to 12 characters (0 to 9, A, B, C, D) FM: State Burst, Cont (Continuous) or Off Dev kHz 0 to 100 kHz in 0.01 kHz increments 0 to 100 kHz in 0.01 kHz increments Seq Up to 12 characters (0 to 9, A, B, C, D) Mark Used to select the DTMF timing. Select: 100 to 1000 ms in 1 ms increments Space Used to select the DTMF timing. Select: 100 to 1000 ms in 1 ms increments Volume Used to select the Handset volume level. Select: 0 to 100 Squelch Used to select the Squelch level for Duplex and Transmitter tests. Select: -150 to 50 dBm in 1 dB increments Squelch operates in conjunction with the Receiver RSSI Meter. When the RSSI Meter is under this threshold, then the speaker audio is silenced. The RSSI Meter does not need to be displayed on the screen for squelch to be operational. Speaker Used to select the Speaker Output. Select: Audio In or Mod Aud Out Used to select the Audio Output Connector. Select: Audio In or Mod Save Displays the Save Configuration Screen (para 2-2-7B) to store the current state of the test screen in the internal memory. Recall Displays the Recall Configuration Screen (para 2-2-7A) to recall a stored state of the test screen from internal memory.

Subject to Export Control, see Cover Page for details.

2-23 B. Receiver Test Screen (cont) SCREEN FEATURE FUNCTION Meters (not shown) Several Meters can be selected to appear on the Receiver Test Screen. Meters are selected in the Receiver Test Setup Screen. F1 “Edit” / “Done” / “Zoom” / “Enter” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Zoom Displays the screen of the field selected. Enter Moves cursor into meter / function on test screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen. Meters save configurations and readings. Control frames save settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F4 “Setup” Displays the Receiver Test Setup Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

B. Receiver Test Screen (cont) RECEIVER TEST SETUP SINAD Meter 0 Distortion Meter 0 AF Counter 0 Audio Level 0 7 Edit Return 1 4 2 5 8 3 6 9 41 20 29 SINAD Audio In 0.0 dB Distortion Audio In 0.0% AF Cntr Audio In 0.0 Hz Audio Level Audio In 0.000 V SCREEN FEATURE FUNCTION SINAD Meter Used to select the position of the SINAD Meter on the Receiver Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 Distortion Meter Used to select the position of the Distortion Meter on the Receiver Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 AF Counter Used to select the position of the AF Counter on the Receiver Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9 Audio Level Used to select the position of the Audio Level Meter on the Receiver Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 6, 8 or 9

Subject to Export Control, see Cover Page for details.

2-25 B. Receiver Test Screen (cont) SCREEN FEATURE FUNCTION Meter Chart Displays the areas of the Receiver Test Screen and a number representing each area (i.e., 3 is top right on the Receiver Test Screen, etc.). F1 “Edit” / “Done” Edit Highlights the selected field to be changed. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Receiver Test Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

C. Transmitter Test Screen When the System Menu is displayed, press the 3 Key to access the Transmitter Test Screen: Edit Return Hold Setup TRANSMITTER TEST Receiver More MH z: 40.000000 Port: T/R Mod: FM 10k AFBW: None Volume: 100 Squelch: -50 dBm Speaker: Audio In AudOut: Audio In Save Recal l 41 20 29 SCREEN FEATURE FUNCTION MHz Used to select the signal receiver frequency. Range: 2.000000 to 1000.000000 MHz in 0.000001 MHz increments Port Used to select the signal receiver input connector. Select: Ant or T/R Mod Used to select the signal receiver modulation type. Select: AM Modulation Meter changes to AM%. FM Modulation Meter changes to FM DEV. IFBW (field to right of Mod Field) Used to select the IF bandwidth. Select: (for AM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k or 30k (for FM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k, 30k, 100k or 300k AFBW Used to select the bandwidth filter. Select: 0.3k LP, 3k LP, 5k LP, 15k LP, CCITT BP, C-Wt BP, 0.3-3k BP, 0.3-5k BP, 0.3-20k BP, 0.3k HP or None. More Toggles the Receiver Frame to display the Ext Attn dB and Preamp Fields. Ext Attn dB Used to select the external attenuation on the input connector. Select: 0.0 to 30.0 dB in 0.1 dB increments TRANSMITTER TEST Receiver More Ext Attn dB: 0.0 Preamp: Auto

Subject to Export Control, see Cover Page for details.

2-27 C. Transmitter Test Screen (cont) SCREEN FEATURE FUNCTION Preamp (Receiver) Used to select preamp operation. Select: Auto, On or Off Volume Used to select the Handset volume level. Select: 0 to 100 Squelch Used to select the Squelch level for Duplex and Transmitter tests. Select: -150 to 50 dBm in 1 dB increments Squelch operates in conjunction with the Receiver RSSI Meter. When the RSSI Meter is under this threshold, then the speaker audio is silenced. The RSSI Meter does not need to be displayed on the screen for squelch to be operational. Speaker Used to select the Speaker Output. Select: Audio In, Demod or Fgen Aud Out Used to select the Audio Output Connector. Select: Audio In, Demod or Fgen Save Displays the Save Configuration Screen (para 2-2-7B) to store the current state of the test screen in the internal memory. Recall Displays the Recall Configuration Screen (para 2-2-7A) to recall a stored state of the test screen from internal memory. Meters (not shown) Several Meters can be selected to appear on the Transmitter Test Screen. Meters are selected in the Transmitter Test Setup Screen. F1 “Edit” / “Done” / “Zoom” / “Enter” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Zoom Displays the screen of the field selected. Enter Displays additional fields on test screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen. Meters save configurations and readings. Control frames save settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Find” Hold Freezes the screen. Resume Restores the screen to active mode. Find Used to scan and find RF signals. F4 “Setup” Displays the Transmitter Test Setup Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

C. Transmitter Test Screen (cont) When the Transmitter Test Screen is displayed, press the F4 “Setup” Key to access the Transmitter Test Setup Screen: TX TEST SETUP Fgen 0 DTMF Decode 0 Modulation Meter 0 DCS Decode 0 RSSI Meter 0 Audio Level 0 RF Error Meter 0 Distortion Meter 0 SINAD Meter 0 RF Power Meter 0 AF Counter 0 Edit Return 1 4 7 2 5 8 3 6 9 41 20 29 Function Generator Freq Level #1: Off 0.0 Hz 0.20 Vrms #2: Off 0.0 Hz 0.20 Vrms Mod-FM Dev 16.670 kHz RSSI 0.0 dBm RF Error 0.0 kHz Distortion Audio In 0.0% SINAD Audio In 0.0 dB RF Power 0.0 Watts AF Cntr Audio In 0.0 Hz DTMF Decode 01234 0123456789 DCS Decode State Run Inv 155 Audio Level Audio In 0.000 V

Subject to Export Control, see Cover Page for details.

2-29 C. Transmitter Test Screen (cont) SCREEN FEATURE FUNCTION Fgen (Function Generator) Used to select the position of the Function Generator on the Transmitter Test Screen (refer to Meter Chart). Since the Function Generator occupies the screen space of two functions on the Transmitter Test Screen, the space directly adjacent to the screen space selected must be empty in order for the Function Generator to be displayed. (e.g. To select screen space 2; screen space 3 must be empty) Select: 0 (Meter not shown), 2, 4, 5 or 8 Status Select: On or Off Freq Select: 0 to 20000 Hz in 0.1 Hz increments Level Select: 0.00 to 1.57 Vrms in 0.01 V increments The Function Generator utilizes the AUDIO Connector for signal output. Modulation Meter Used to select the position of the Modulation Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 RSSI Meter Used to select the position of the RSSI Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 RF Error Meter Used to select the position of the RF Error Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 Distortion Meter Used to select the position of the Distortion Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 SINAD Meter Used to select the position of the SINAD Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 RF Power Meter Used to select the position of the RF Power Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 AF Counter Used to select the position of the AF Counter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 DTMF Decode Used to select the position of the DTMF Decode Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 DCS Decode Used to select the position of the DCS Decode Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9

Subject to Export Control, see Cover Page for details.

C. Transmitter Test Screen (cont) SCREEN FEATURE FUNCTION Audio Level Used to select the position of the Audio Level Meter on the Transmitter Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9 Meter Chart Displays the areas of the Transmitter Test Screen and a number representing each area (i.e., 3 is top right on the Transmitter Test Screen, etc.). F1 “Edit” / “Done” Edit Highlights the selected field to be changed. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Transmitter Test Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-31 D. ANT-Cable Test Screen When the System Menu is displayed, press the 4 Key to access the ANT-Cable Test Screen: ANT-CABLE TEST 7.00 2009-01-06 11:35:30 SWR 1.00 35.0 MHz 45.0 Type: SWR Freq (MHz): 40.0 Span (MHz): 10.0 Start (MHz): 35.0 Stop (MHz): 45.0 Edit Return Hold Cal Marker 41 20 29 (RF Mode) SCREEN FEATURE FUNCTION VSWR Progress Bar A graphical representation of the percentage completed for the current measurement. Type Used to select the mode of testing. Select: SWR, DTF, RL, LOSS or Raw Freq Used to select/display the Center Frequency. Range: 2.0 to 1000.0 MHz in 0.1 MHz increments Displays the Center Frequency entered by the operator or the calculated Center Frequency if the Start and Stop Frequencies are entered. Span Used to select/display the Frequency Span. Range: (SWR) 10 to 998 MHz in 0.1 MHz increments (DTF) 100 to 998 MHz in 0.1 MHz increments (RL) 10 to 998 MHz in 0.1 MHz increments (LOSS) 10 to 998 MHz in 0.1 MHz increments Displays the Frequency Span entered by the operator or the calculated Frequency Span if the Start and Stop Frequencies are entered.

Subject to Export Control, see Cover Page for details.

D. ANT-Cable Test Screen (cont) SCREEN FEATURE FUNCTION Start Used to select/display the Start Frequency. Range: 2.0 to 1000 MHz in 0.1 MHz increments Displays the Start Frequency entered by the operator or the calculated Start Frequency if the Center Frequency and Frequency Span are entered. Stop Used to select/display the Stop Frequency. Range: 2.0 to 1000 MHz in 0.1 MHz increments Displays the Stop Frequency entered by the operator or the calculated Stop Frequency if the Center Frequency and Frequency Span are entered. F1 “Edit” / “Done” / “Next” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Next Displays the next pop-up screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Abort” Hold Freezes the screen. Resume Restores the screen to active mode. Abort Stops the action to calibrate the SWR Connector. F4 “Cal” Instruction pop-ups are displayed to calibrate the SWR Connector. F5 “Marker” / “Scale” “RF” / “Esc” Marker Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Marker Mode. Scale Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Scale Mode. RF Used to change the displayed fields and functionality on the ANT-Cable Test Screen to RF Mode. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-33 D. ANT-Cable Test Screen (cont) ANT-CABLE TEST 7.00 2009-06-25 11:35:30 SWR 1.00 35.0 MHz 45.0 Marker: 1 Off Delta: 1 Pos: 0.00 Delta 0.00 Move Left Right VSWR 0.00 Delta 0.00 Edit Return Hold Cal Scale 41 20 29 (Marker Mode) ANT-CABLE TEST 0.00 2009-06-25 11:35:30 dB -50.0 0.1 Ft 415.5 Marker: 1 Off Delta: 1 Pos: 0.00 Delta 0.00 Move Left Right dB 0.00 Delta 0.00 Edit Return Hold Cal Cable 41 20 29 (DTF - Marker Mode)

Subject to Export Control, see Cover Page for details.

D. ANT-Cable Test Screen (cont) SCREEN FEATURE FUNCTION VSWR Progress Bar A graphical representation of the percentage completed for the current measurement. Marker Used to select and enable one of three markers on the Graphical Display. Select: 1 to 3 Marker Status Used to set the Marker selected to ON or OFF. Delta Used to enable the Delta Marker Function. Select: 1 to 3 DTF Displays the distance to fault. Delta (Top) Displays the Delta in SWR/Return Loss between the Active Marker selected in the Marker Field and the Marker selected in the Delta Field. Move/Min/Max Used to move the Active Marker on the Graphical Display. Select: Max, Min or Move Left Right Used to move the Active Marker selected in the Marker Field to the left or to the right on the Graphical Display. Pos Displays the Horizontal Axis of the Active Marker. VSWR / dB Displays the reading of the Active Marker. VSWR Displays the SWR reading. dB Displays the DTF, RL or LOSS reading. Delta (Bottom) Displays the Delta in Frequency or Distance between the Active Marker selected in the Marker Field and the Marker selected in the Delta Field. F1 “Edit” / “Done” / “Next” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Next Displays the next pop-up screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Abort” Hold Freezes the screen. Resume Restores the screen to active mode. Abort Stops the action to calibrate the SWR Connector. F4 “Cal” Instruction pop-ups are displayed to calibrate the SWR Connector.

Subject to Export Control, see Cover Page for details.

2-35 D. ANT-Cable Test Screen (cont) SCREEN FEATURE FUNCTION F5 “Marker” / “Scale” “Cable” / “RF” / “Esc” Marker Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Marker Mode. Scale Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Scale Mode. Cable Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Cable Mode. RF Used to change the displayed fields and functionality on the ANT-Cable Test Screen to RF Mode. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

D. ANT-Cable Test Screen (cont) ANT-CABLE TEST 0.00 2009-06-25 11:35:30 dB -50.0 0.1 Ft 415.5 Cable: USER Velocity: 0.66 Loss: 3.00 Est Length: 415.5 Unit Feet Edit Return Hold Cal Scale 41 20 29 (DTF - Cable Mode) SCREEN FEATURE FUNCTION VSWR Progress Bar A graphical representation of the percentage completed for the current measurement. Cable Used to select the type of coaxial cable used on the system under test. Select: RG-400, RG-223, RG-214, RG-213, RG-174, RG-58C, RG-58B, RG-58A, RG-58foam, RG-58, RG-55B, RG-55A, RG-55, RG-8A, RG-8foam, RG-8, RG-8x or USER. Velocity Used to select the velocity of the propergation (Vp) factor for the cable selected. Select: 0.0 to 1.0 in 0.01 increments Loss Used to select the cable insertion loss per 100 ft for the cable selected. Select: 0.00 to 100.00 in 0.01 increments Est Length Used to select the estimated length of the cable under test. Select: 42.0 to 619.4 ft in 0.1 ft increments. 12.8 to 304.8 m in 0.1 m increments When an estimated length is entered, the frequency span adjusts to the correct level automatically. Unit Used to select the units of measure. Select: Feet or Meters

Subject to Export Control, see Cover Page for details.

2-37 D. ANT-Cable Test Screen (cont) SCREEN FEATURE FUNCTION F1 “Edit” / “Done” / “Next” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Next Displays the next pop-up screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Abort” Hold Freezes the screen. Resume Restores the screen to active mode. Abort Stops the action to calibrate the SWR Connector. F4 “Cal” Instruction pop-ups are displayed to calibrate the SWR Connector. F5 “Marker” / “Scale” “RF” / “Esc” Marker Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Marker Mode. Scale Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Scale Mode. RF Used to change the displayed fields and functionality on the ANT-Cable Test Screen to RF Mode. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

D. ANT-Cable Test Screen (cont) ANT-CABLE TEST 7.0 0.00 2009-01-06 11:35:30 dB -50.0 0.1 Ft 415.5 Scale: User Top: 0 Bottom: -50 Edit Return Hold Cal RF 41 20 29 (Scale Mode) SCREEN FEATURE FUNCTION VSWR Progress Bar A graphical representation of the percentage completed for the current measurement. Scale Used to scale the Vertical Axis of the Graphical Display. Select: Fixed or User Top Used to set the upper limit of the Vertical Axis. Select: -100 to 100 Bottom Used to set the lower limit of the Vertical Axis. Select: -100 to 100 F1 “Edit” / “Done” / “Next” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Next Displays the next pop-up screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” / “Abort” Hold Freezes the screen. Resume Restores the screen to active mode. Abort Stops the action to calibrate the SWR Connector. F4 “Cal” Instruction pop-ups are displayed to calibrate the SWR Connector.

Subject to Export Control, see Cover Page for details.

2-39 D. ANT-Cable Test Screen (cont) SCREEN FEATURE FUNCTION F5 “Marker” / “Scale” “RF” / “Esc” Marker Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Marker Mode. Scale Used to change the displayed fields and functionality on the ANT-Cable Test Screen to Scale Mode. RF Used to change the displayed fields and functionality on the ANT-Cable Test Screen to RF Mode. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

E. Audio Function Generator Test Screen When the System Menu is displayed, press the 5 Key to access the Audio Function Generator Test Screen. The Audio Function Generator Test Screen utilizes the AUDIO Connector for signal output. Edit Return Hold Setup AF GEN Function Generator Freq Level # 1: On 1000.0 Hz 1.00 Vrms # 2: On 2400.0 Hz 1.00 Vrms Volume: 100 Squelch: -50 dBm Speaker: Audio In AudOut: Audio In Save Recal l 41 20 29 SCREEN FEATURE FUNCTION #1 (Function Generator) Used to select Function Generator #1. Select: On or Off Freq 0 to 20000 Hz in 0.1 Hz increments Level 0.00 to 1.57 Vrms in 0.01 V increments #2 (Function Generator) Used to select Function Generator #2. Select: On or Off Freq 0 to 20000 Hz in 0.1 Hz increments Level 0.00 to 1.57 Vrms in 0.01 V increments NOTE: The combined output level from both Function Generators cannot exceed 1.57 Vrms. If the level of a selected Function Generator is set so the combined output level would exceed 1.57 Vrms, then the output level of the unselected Function Generator is lowered automatically. Volume Used to select the Handset volume level. Select: 0 to 100

Subject to Export Control, see Cover Page for details.

2-41 E. Audio Function Generator Test Screen (cont) SCREEN FEATURE FUNCTION Squelch Used to select the Squelch level for Duplex and Transmitter tests. Select: -150 to 50 dBm in 1 dB increments Squelch operates in conjunction with the Receiver RSSI Meter. When the RSSI Meter is under this threshold, then the speaker audio is silenced. The RSSI Meter does not need to be displayed on the screen for squelch to be operational. Speaker Used to select the Speaker Output. Select: Audio In, Demod or Fgen Aud Out Used to select the Audio Output Connector. Select: Audio In, Demod or Fgen Save Displays the Save Configuration Screen (para 2-2-7B) to store the current state of the test screen in the internal memory. Recall Displays the Recall Configuration Screen (para 2-2-7A) to recall a stored state of the test screen from internal memory. Meters (not shown) Several Meters can be selected to appear on the Audio Function Generator Screen. Meters are selected in the Audio Function Generator Setup Screen. F1 “Edit” / “Done” / “Zoom” / “Enter” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. Zoom Displays the screen of the field selected. Enter Moves cursor into meter / function on test screen. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen. Meters save configurations and readings. Control frames save settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F4 “Setup” Displays the Audio Function Generator Setup Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

E. Audio Function Generator Test Screen (cont) When the Audio Function Generator Test Screen is displayed, press the F4 “Setup” Key to access the Audio Function Generator Test Setup Screen: AF GEN SETUP SINAD Meter 0 Distortion Meter 0 AF Counter 0 Audio Level 0 7 Edit Return 1 4 2 5 8 3 6 9 41 20 29 SINAD Audio In 0.0 dB Distortion Audio In 0.0% AF Cntr Audio In 0.0 Hz Audio Level Audio In 0.000 V SCREEN FEATURE FUNCTION SINAD Meter Used to select the position of the SINAD Meter on the Audio Function Generator Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 4, 5, 6, 8 or 9 Distortion Meter Used to select the position of the Distortion Meter on the Audio Function Generator Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 4, 5, 6, 8 or 9 AF Counter Used to select the position of the AF Counter on the Audio Function Generator Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 4, 5, 6, 8 or 9

Subject to Export Control, see Cover Page for details.

2-43 E. Audio Function Generator Test Screen (cont) SCREEN FEATURE FUNCTION Audio Level Used to select the position of the Audio Level Meter on the Audio Function Generator Test Screen (refer to Meter Chart). Select: 0 (Meter not shown), 3, 4, 5, 6, 8 or 9 Meter Chart Displays the areas of the Audio Function Generator Test Screen and a number representing each area (i.e., 3 is top right on the Audio Function Generator Test Screen, etc.). F1 “Edit” / “Done” Edit Highlights the selected field to be changed. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Audio Function Generator Test Screen. F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-2-3. METERS MENU When the System Menu, Self Test Menu or Utilities Menu is displayed, press the F2 “Meters” Key to access the Meters Menu: Meters System Selftest Util 1 - SINAD 2 - DISTORTION 3 - AF COUNTER 4 - AUDIO LEVEL METER SCREEN FEATURE FUNCTION 1 - SINAD Displays the SINAD Meter Screen (para 2-2-3A). 2 - DISTORTION Displays the Distortion Meter Screen (para 2-2-3B). 3 - AF COUNTER Displays the AF Counter Screen (para 2-2-3C). 4 - AUDIO LEVEL METER Displays the Audio Level Meter Screen (para 2-2-3D). F2 “Meters” Displays the Meters Menu (para 2-2-3). F3 “System” Displays the System Menu (para 2-2-2). F4 “Selftest” Displays the Self Test Menu (para 2-2-4). F5 “Util” Displays the Utilities Menu (para 2-2-5).

Subject to Export Control, see Cover Page for details.

2-45 A. SINAD Meter Screen When the Meters Menu is displayed, press the 1 Key to access the SINAD Meter Screen: The SINAD Meter Screen utilizes the AUDIO Connector and AUDIO IN Connector for signal input. SINAD Audio In 0.0 dB Edit Return Hold SINAD Source Audio In Load High Z Avg Reading 1 Range Auto Filter 15k LP Limits dB State Lower 0.0 Off Upper 60.0 Off 59.1 0.0 dB 60.0 41 20 29 (MINI-METER) SCREEN FEATURE FUNCTION Source Used to select the SINAD Meter input source on the SINAD Meter Screen and/or the SINAD Mini-Meter. Select: Audio In or Demod (Duplex Test Screen) Audio In (Receiver Test Screen) Audio In or Demod (Transmitter Test Screen) Audio In (Audio Function Generator Screen) When the SINAD Meter Screen is selected from the Meters Menu, ‘Audio In’ is the only setting available. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z Avg Reading Used to select the SINAD Meter Averaging. Select: 1 to 99 This is the number of readings to average for the displayed value. Range Used to select the meter range. Select: Auto, 0-20dB, 0-40dB or 0-60dB Filter Used to select the audio filter. Select: None. 15k LP or 0.3-3k BP

Subject to Export Control, see Cover Page for details.

A. SINAD Meter Screen (cont) SCREEN FEATURE FUNCTION Limits - Lower Used to enable the SINAD Meter Low Limit. Select: 0.0 to 60.0 dBm in 0.1 dB increments Sets the marker on the SINAD Meter Bar to the Lower Limit selected. Limits - Upper Used to enable the SINAD Meter Upper Limit. Select: 0.0 to 60.0 dBm in 0.1 dB increments Sets the marker on the SINAD Meter Bar to the Upper Limit selected. State - Lower Limit Used to display the Lower Limit Marker on the SINAD Meter Bar. Select: On or Off State - Upper Limit Used to display the Upper Limit Marker on the SINAD Meter Bar. Select: On or Off SINAD Meter Bar A graphical representation of the received SINAD Meter readings. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F5 “Return” / “Esc” Return Closes the SINAD Meter Screen and returns to the Test Screen. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-47 B. Distortion Meter Screen When the Meters Menu is displayed, press the 2 Key to access the Distortion Meter Screen: The Distortion Meter Screen utilizes the AUDIO Connector and AUDIO IN Connector (3500A only) for signal input. Distortion Audio In 0.0% Edit Return Hold DISTORTION Source: Audio In Load: 150 Avg Reading: 1 Range: Auto Filter: 15k LP Limits % State Lower 0.0 Off Upper 100.0 Off 99.0 0.0 % 100.0 41 20 29 (MINI-METER) SCREEN FEATURE FUNCTION Source Used to select the Distortion Meter input source on the Distortion Meter Screen and/or the Distortion Mini-Meter. Select: Audio In or Demod (Duplex Test Screen) Audio In (Receiver Test Screen) Audio In or Demod (Transmitter Test Screen) Audio In (Audio Function Generator Screen) When the Distortion Meter Screen is selected from the Meters Menu, ‘Audio In’ is the only setting available. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z Avg Reading Used to select the Distortion Meter Averaging. Select: 1 to 99 This is the number of readings to average for the displayed value. Range Used to select the meter range. Select: Auto, 0-10%, 0-20%, 0-50% or 0-100% Filter Used to select the audio filter. Select: None. 15k LP or 0.3-3k BP

Subject to Export Control, see Cover Page for details.

B. Distortion Meter Screen (cont) SCREEN FEATURE FUNCTION Limits - Lower Used to enable the Distortion Meter Low Limit. Select: 0.0% to 100.0% in 0.1% increments Sets the marker on the Distortion Bar to the Lower Limit selected. Limits - Upper Used to enable the Distortion Meter Upper Limit. Select: 0.0% to 100.0% in 0.1% increments Sets the marker on the Distortion Meter Bar to the Upper Limit selected. State - Lower Limit Used to display the Lower Limit Marker on the Distortion Meter Bar. Select: On or Off State - Upper Limit Used to display the Upper Limit Marker on the Distortion Meter Bar. Select: On or Off Distortion Meter Bar A graphical representation of the received Distortion Meter readings. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F5 “Return” / “Esc” Return Closes the Distortion Meter Screen and returns to the Test Screen. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-49 C. AF Counter Screen When the Meters Menu is displayed, press the 3 Key to access the AF Counter Screen: The AF Counter Screen utilizes the AUDIO Connector and AUDIO IN Connector (3500A only) for signal input. AF Cntr Audio In 0.0 Hz Edit Return Hold AF COUNTER Source Audio In Load High Z Avg Reading 1 Range Auto Limits Hz State Lower 15.0 Off Upper 20000.0 Off 4926.0 15.0 Hz 20000.0 41 20 29 (MINI-METER) SCREEN FEATURE FUNCTION Source Used to select the AF Counter input source on the AF Counter Screen and/or the AF Counter Mini-Meter. Select: Audio In, Demod, or Mod (Duplex Test Screen) Audio In or Mod (Receiver Test Screen) Audio In, Demod or Fgen (Transmitter Test Screen) Audio In or Fgen (Audio Function Generator Test Screen) When the AF Counter Screen is selected from the Meters Menu, ‘Audio In’ is the only setting available. Load Used to select the Audio input signal load (Ω). Select: 150, 600, 1K (3500A), Div10 (3500A) or High Z Avg Reading Used to select the AF Counter Averaging. Select: 1 to 99 This is the number of readings to average for the displayed value. Range Used to select the meter range. Select: Auto, 15-100Hz, 15-1000Hz, 15-10000Hz or 15-20000Hz Limits - Lower Used to select the AF Counter Lower Limit. Select: 15.0 to 20000.0 Hz in 0.1 Hz increments Sets the marker on the AF Counter Bar to the Lower Limit selected.

Subject to Export Control, see Cover Page for details.

C. AF Counter Screen (cont) SCREEN FEATURE FUNCTION Limits - Upper Used to select the AF Counter Upper Limit. Select: 15.0 to 20000.0 Hz in 0.1 Hz increments Sets the marker on the AF Counter Bar to the Upper Limit selected. State - Lower Limit Used to display the Lower Limit Marker on the AF Counter Bar. Select: On or Off State - Upper Limit Used to display the Upper Limit Marker on the AF Counter Bar. Select: On or Off AF Counter Bar A graphical representation of the received AF Counter readings. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F5 “Return” / “Esc” Return Closes the AF Counter Screen and returns to the Test Screen. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-51 D. Audio Level Meter Screen When the Meters Menu is displayed, press the 4 Key to access the Audio Level Meter Screen. The Audio Level Meter Screen utilizes the AUDIO Connector, AUDIO IN Connector (3500A only) and DVM Connector (3500A only) for signal input. Audio Level Audio In 0.000 V Edit Return Hold AUDIO LEVEL METER Source DVM Detector RMS DivBy20 Off Load High Z Ext Load 1 Range Auto Unit V Avg Reading 1 Limits Vol ts State Lower 0.0 Off Upper 50.0 Off 11.400 0.0 V 50.0 41 20 29 (MINI-METER) SCREEN FEATURE FUNCTION Source Used to select the Audio Level Meter input source on the Audio Level Meter Screen and/or the Audio Level Meter Mini-Meter. Select: Audio In or DVM Detector Used to select the measurement type. Select: Peak+, Peak-, PK2PK or RMS DivBy20 Used to select the divide-by-20 function on the output level (DVM only) Select: On or Off Load Used to select the Audio input signal load (Ω). Select: Audio In 150, 600, 1K (3500A), Div10 (3500A) or High Z DVM High Z Ext Load Used to select the impedance of an external load. The selected impedance value is used to calculate power when the Unit Field is set to dBm or Watts. Select: 1 to 90000 Ω in 1 Ω increments Range Used to select the meter range. Select: Auto, 0-0.1V, 0-0.2V, 0-0.5V, 0-1V or 0-3.5V

Subject to Export Control, see Cover Page for details.

D. Audio Level Meter Screen (cont) SCREEN FEATURE FUNCTION Unit Used to select the Audio Level Meter units of measure. Select: dBm, dBuV, mV, V or Watts Avg Reading Used to select the Audio Level Meter Averaging. Select: 1 to 99 This is the number of readings to average for the displayed value. Limits - Lower Used to select the Audio Level Meter Lower Limit. Select: 0.0 to 100.0 V in 0.1 V increments Sets the marker on the Audio Level Meter Bar to the Lower Limit selected. Limits - Upper Used to select the Audio Level Meter Upper Limit. Select: 0.0 to 100.0 V in 0.1 V increments Sets the marker on the Audio Level Meter Bar to the Upper Limit selected. State - Lower Limit Used to display the Lower Limit Marker on the Audio Level Meter Bar. Select: On or Off State - Upper Limit Used to display the Upper Limit Marker on the Audio Level Meter Bar. Select: On or Off AF Counter Bar A graphical representation of the received Audio Level Meter readings. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” / “Save” Return Displays the System Menu (para 2-2-2) Save Performs a data dump of frames displayed on the screen, including configurations, readings and settings. The data dump is stored in a time-stamped ASCII report and can be retrieved at a later time. F3 “Hold” / “Resume” Hold Freezes the screen. Resume Restores the screen to active mode. F5 “Return” / “Esc” Return Closes the Audio Level Meter Screen and returns to the Test Screen. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-53 2-2-4. SELF TEST MENU When the System Menu, Self Test Menu or Utilities Menu is displayed, press the F4 “Selftest” Key to access the Self Test Menu: Meters System Selftest Util 1 - SELFTEST 2 - DIAGNOSTIC 3 - CALIBRATION SCREEN FEATURE FUNCTION 1 - SELFTEST Displays the Self Test Screen (para 2-2-4A). 2 - DIAGNOSTIC Displays the Diagnostic Screen (para 2-2-4B). 3 - CALIBRATION Displays the Calibration Screen (para 2-2-4C). F2 “Meters” Displays the Meters Menu (para 2-2-3). F3 “System” Displays the System Menu (para 2-2-2). F4 “Selftest” Displays the Self Test Menu (para 2-2-4). F5 “Util” Displays the Utilities Menu (para 2-2-5).

Subject to Export Control, see Cover Page for details.

A. Self Test Screen When the Self Test Menu is displayed, press the 1 Key to access the Self Test Screen: Edit Return Start SELF TEST Test Mode: Normal Run TDM Pass 0 Fail 0 Modulation Pass 0 Fail 0 41 20 29 SCREEN FEATURE FUNCTION Test Mode Used to select the run mode of the Self Test. Select: Normal Run (runs Self Test one time) Loop All (runs Self Test continuously) TDM Displays the pass/fail status of the TDM (Time-Division Multiplexing) Self Test. Each time the test is performed, the fields next to Pass or Fail are incremented. The fields are cleared if the Self Test is re-initialized. Modulation Displays the pass/fail status of the Modulation Self Test. Each time the test is performed, the fields next to Pass or Fail are incremented. The fields are cleared if the Self Test is restarted. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Self Test Menu (para 2-2-4). F5 “Start” / “Stop” / “Esc” Start Initiates the Self Test. Stop Terminates the Self Test. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

2-55 B. Diagnostic Screen When the Self Test Menu is displayed, press the 2 Key to access the Diagnostic Screen: Edit Return Start STAND ALONE TEST Mode: Normal Run RF CPLD Invalid Distortion Invalid TDM Invalid Gen Lock Invalid FPGA Invalid Rec Lock Invalid Temperature Invalid Button Battery Invalid AM Mod Invalid AF Counter Invalid FM Mod Invalid Time Domain Invalid RF Power Invalid Freq Domain Invalid RF Error Invalid SWR Invalid RSSI Invalid DTMF Invalid SPI Invalid DCS Invalid SINAD Invalid RF CPLD Pass: 0 Fail: 0 41 20 29 SCREEN FEATURE FUNCTION Mode Used to select the run mode of the Diagnostic Tests. Select: Normal Run, Loop Selected, Run Selected or Loop All RF CPLD Used to test Complex Programmable Logic Device. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. TDM Used to test the Time-Division Multiplexing. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. FPGA Used to test the Field Programmable Gate Array. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Temperature Used to test the Temperature. Sensing Devices. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. AM Mod Used to test AM Modulation. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. FM Mod Used to test FM Modulation. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED.

Subject to Export Control, see Cover Page for details.

B. Diagnostic Screen (cont) SCREEN FEATURE FUNCTION RF Power Used to test RF Power. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. RF Error Used to test RF Error. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. RSSI Used to test the Received Signal Strength Indication. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. SPI Used to test Serial Peripheral Interface. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. SINAD Used to test the SINAD Meter. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Distortion Used to test the Distortion Meter. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Gen Lock Used to test the Generator (1st LO / 2nd LO). The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Rec Lock Used to test the Receiver (1st LO / 2nd LO). The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Button Battery Used to test the battery used to maintain non-volatile memory. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. AF Counter Used to test the AF Counter. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Time Domain Used to test the Time Domain. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Freq Domain Used to test the Frequency Domain. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. SWR Used to test the SWR. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED.

Subject to Export Control, see Cover Page for details.

2-57 B. Diagnostic Screen (cont) SCREEN FEATURE FUNCTION DTMF Used to test the DTMF. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. DCS Used to test the DCS. The test status field (right of the test) displays INVALID until the test is run, then displays RUNNING, STOPPED, PASSED or FAILED. Pass / Fail Counters Displays Pass / Fail record of the Diagnostic Test selected. The Pass / Fail Counters are incremented each time the test is performed. The Pass / Fail Counters are cleared if the Diagnostics Screen is re-initialized. F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Self Test Menu (para 2-2-4). F5 “Start” / “Stop” / “Esc” Start Initiates the Diagnostic Testing. Stop Terminates the Diagnostic Testing. Esc Ends the Field Edit, but does NOT save any changes to the setting or value.

Subject to Export Control, see Cover Page for details.

C. Calibration Screen When the Self Test Menu is displayed, press the 3 Key to access the Calibration Screen: Edit Return CALIBRATION CAL PASSWORD: 0 41 20 29 SCREEN FEATURE FUNCTION CAL PASSWORD Used to enter the Calibration Password. F1 “Edit” / “Done” Edit Highlights the selected field to be changed. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Self Test Menu (para 2-2-4). F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value. Refer to the 3500 / 3500A Maintenance Manual for more information on calibrating the 3500 / 3500A.

Subject to Export Control, see Cover Page for details.

2-59 2-2-5. UTILITIES SCREEN When the System Menu, Meters Menu or Self Test Menu is displayed, press the F5 “Util” Key to access the Utilities Menu: Meters System Selftest Util 1 - ANNUNCIATOR 2 - REMOTE 3 - VERSION 4 - DATE AND TIME 5 - HW CONFIG 6 - OPTIONS 7 - USB MANAGER 8 - UNIT COPY SCREEN FEATURE FUNCTION 1 - ANNUNCIATOR Displays the Annunciator Screen (para 2-2-5A). 2 - REMOTE Displays the Remote Screen (para 2-2-5B). 3 - VERSION Displays the Version Screen (para 2-2-5C). 4 - DATE / TIME Displays the Date / Time Screen (para 2-2-5D). 5 - HW CONFIG Displays the HW Config Screen (para 2-2-5E). 6 - OPTIONS Displays the Options Screen (para 2-2-5F). 7 - USB MANAGER Displays the USB Manager Screen (para 2-2-5G). 8 - UNIT COPY Displays the Unit Copy Screen (para 2-2-5H). F2 “Meters” Displays the Meters Menu (para 2-2-3). F3 “System” Displays the System Menu (para 2-2-2). F4 “Selftest” Displays the Self Test Menu (para 2-2-4). F5 “Util” Displays the Utilities Menu (para 2-2-5).

Subject to Export Control, see Cover Page for details.

A. Annunciator Screen When the Utilities Menu is displayed, press the 1 Key to access the Annunciator Screen: Edit Return ANNUNCIATOR Alarm: On Key Press: Off PTT: Off 41 20 29 SCREEN FEATURE FUNCTION Alarm Used to enable the audible alarm. Select: On or Off Key Press Used to enable the audible tone on each key press. Select: On or Off PTT Used to enable the audible tone when the PTT is pressed on the microphone. Select: On or Off F1 “Edit” / “Done” Edit Highlights the selected field to be changed or changes the field value if the field only contains two selections. Done Ends the Field Edit and saves the new setting / value. F2 “Return” Displays the Utilities Menu (para 2-2-5). F5 “Esc” Ends the Field Edit, but does NOT save any changes to the setting or value.

Other Test Equipment Manuals