Aeroflex 3500 Operation Manual
Read Online
Read the Aeroflex 3500 Operation Manual online using the built-in PDF viewer.
Text of the manual
EXPORT CONTROL WARNING: This document contains controlled technology or technical data
under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot
be transferred to any foreign third party without the specific prior approval of the U.S. Department
of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable
by fine, imprisonment, or both.
Communications
Test Set
3500 / 3500A
Operation Manual
Issue-4
Subject to Export Control, see Cover Page for details.
OPERATION MANUAL
COMMUNICATIONS TEST SET
3500 / 3500A
PUBLISHED BY
Aeroflex
COPYRIGHT © Aeroflex 2010
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise without the prior permission of the publisher.
Reissued
Jan 2010
Issue-2
Apr 2010
Issue-3
May 2010
Issue-4
Mar 2011
10200 West York / Wichita, Kansas 67215 U.S.A. / (316) 522-4981 / FAX (316) 524-2623
Subject to Export Control, see Cover Page for details.
Electromagnetic Compatibility:
For continued EMC compliance, all external cables must be shielded and three meters or less in
length.
Nomenclature Statement:
In this manual, 3500 / 3500A, Test Set or Unit refers to the 3500 / 3500A Communications Test Set.
Subject to Export Control, see Cover Page for details.
SAFETY FIRST: TO ALL OPERATIONS PERSONNEL
REFER ALL SERVICING OF UNIT TO QUALIFIED TECHNICAL PERSONNEL. THIS UNIT CONTAINS NO
OPERATOR SERVICEABLE PARTS.
WARNING: USING THIS EQUIPMENT IN A MANNER NOT SPECIFIED BY THE ACCOMPANYING
DOCUMENTATION MAY IMPAIR THE SAFETY PROTECTION PROVIDED BY THE EQUIPMENT.
CASE, COVER OR PANEL REMOVAL
Opening the Case Assembly exposes the operator to electrical hazards that can result in electrical shock or
equipment damage. Do not operate this Test Set with the Case Assembly open.
SAFETY IDENTIFICATION IN TECHNICAL MANUAL
This manual uses the following terms to draw attention to possible safety hazards, that may exist when
operating or servicing this equipment.
CAUTION: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN
EQUIPMENT OR PROPERTY DAMAGE (E.G., FIRE).
WARNING: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN
PERSONAL INJURY OR DEATH.
SAFETY SYMBOLS IN MANUALS AND ON UNITS
CAUTION: Refer to accompanying documents. (This symbol refers to specific CAUTIONS
represented on the unit and clarified in the text.)
AC OR DC TERMINAL: Terminal that may supply or be supplied with AC or DC voltage.
DC TERMINAL: Terminal that may supply or be supplied with DC voltage.
AC TERMINAL: Terminal that may supply or be supplied with AC or alternating voltage.
EQUIPMENT GROUNDING PRECAUTION
Improper grounding of equipment can result in electrical shock.
USE OF PROBES
Check the specifications for the maximum voltage, current and power ratings of any connector on the Test Set
before connecting it with a probe from a terminal device. Be sure the terminal device performs within these
specifications before using it for measurement, to prevent electrical shock or damage to the equipment.
POWER CORDS
Power cords must not be frayed, broken nor expose bare wiring when operating this equipment.
USE RECOMMENDED FUSES ONLY
Use only fuses specifically recommended for the equipment at the specified current and voltage ratings.
INTERNAL BATTERY
This unit contains a Lithium Ion Battery, serviceable only by a qualified technician.
CAUTION: SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TO
COMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTION AND
INTERFERENCE TO COMMUNICATION SERVICES OUT TO A DISTANCE OF SEVERAL MILES.
USERS OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTS IN
RADIATION OF A SIGNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARY
PRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.
Subject to Export Control, see Cover Page for details.
DECLARATION OF CONFORMITY
The Declaration of Conformity Certificate included with
the Unit should remain with the Unit.
Aeroflex recommends the operator reproduce a copy of
the Declaration of Conformity Certificate to be stored
with the Operation Manual for future reference.
Subject to Export Control, see Cover Page for details.
i
SCOPE
This Manual contains Instructions for operating the 3500 / 3500A. It is strongly recommended that
the Operator be thoroughly familiar with this manual before attempting to operate the equipment.
ORGANIZATION
The Manual is composed of the following Chapters:
CHAPTER 1 - INTRODUCTION
Provides an Introduction and a Brief Overview of Functions and Features. Principles of
Operation are also included.
CHAPTER 2 - OPERATING INSTRUCTIONS
Identifies and functionally describes all Controls, Indicators and Connectors.
Identifies and explains all Operation Screens and Menus.
Provides a Turn-On Procedure and Initial Adjustments.
Provides Applications.
CHAPTER 3 - OPERATOR MAINTENANCE
Identifies and explains Routine Service, Troubleshooting, Maintenance and Storage
Procedures.
CHAPTER 4 - OPTIONS
Identifies and explains the Options available for the 3500 / 3500A.
TABLE OF CONTENTS
ii
Subject to Export Control, see Cover Page for details.
PARAGRAPH
PAGE
CHAPTER 1 - INTRODUCTION
1-1
General Information .................................................................................... 1-1
1-1A
Scope .................................................................................................... 1-1
1-1B
Nomenclature Cross-Reference List .......................................................... 1-1
1-2
Equipment Capabilities and Features ............................................................ 1-2
1-2A
Capabilities ............................................................................................ 1-2
1-2B
Features ................................................................................................ 1-3
1-3
Equipment Data .......................................................................................... 1-4
1-4
Principles of Operation ................................................................................ 1-15
CHAPTER 2 - OPERATING INSTRUCTIONS
2-1
Operator’s Controls, Indicators and Connectors.............................................. 2-1
2-2
Operation Screens and Menu Configurations .................................................. 2-5
2-2-1
Screen Icons .......................................................................................... 2-6
2-2-2
System Menu .......................................................................................... 2-8
2-2-2A
Duplex Test Screen............................................................................. 2-9
2-2-2B
Receiver Test Screen .......................................................................... 2-18
2-2-2C
Transmitter Test Screen ...................................................................... 2-26
2-2-2D
ANT-Cable Test Screen ....................................................................... 2-31
2-2-2E
Audio Function Generator Test Screen .................................................. 2-40
2-2-3
Meters Menu .......................................................................................... 2-44
2-2-3A
SINAD Meter Screen ........................................................................... 2-45
2-2-3B
Distortion Meter Screen ....................................................................... 2-47
2-2-3C
AF Counter Screen ............................................................................. 2-49
2-2-3D
Audio Level Meter Screen .................................................................... 2-51
2-2-4
Self Test Menu ....................................................................................... 2-53
2-2-4A
Self Test Screen ................................................................................. 2-54
2-2-4B
Diagnostic Screen............................................................................... 2-55
2-2-4C
Calibration Screen .............................................................................. 2-58
2-2-5
Utilities Menu ......................................................................................... 2-59
2-2-5A
Annunciator Setup Screen ................................................................... 2-60
2-2-5B
Remote Setup Screen .......................................................................... 2-61
2-2-5C
Version Screen ................................................................................... 2-66
2-2-5D
Date / Time Screen ............................................................................. 2-67
2-2-5E
HW Config Setup Screen ..................................................................... 2-68
2-2-5F
Options Screen ................................................................................... 2-70
2-2-5G
USB Manager Screen .......................................................................... 2-71
2-2-5H
Unit Copy Screen ................................................................................ 2-72
2-2-6
Other Meters / Functions ......................................................................... 2-73
2-2-6A
DCS Decode Meter ............................................................................. 2-74
2-2-6B
DTMF Decode Meter ........................................................................... 2-75
2-2-6C
Function Generator ............................................................................. 2-76
2-2-6D
Modulation Meter Screen ..................................................................... 2-77
2-2-6E
RF Error Meter Screen ........................................................................ 2-79
2-2-6F
RF Power Meter Screen ....................................................................... 2-81
2-2-6G
RSSI Meter Screen ............................................................................. 2-83
2-2-7
Other Functions ...................................................................................... 2-85
2-2-7A
Recall Configuration Screen ................................................................ 2-85
2-2-7B
Save Configuration Screen .................................................................. 2-86
2-3
Preventive Maintenance Checks and Services ................................................ 2-87
2-3-1
General ................................................................................................. 2-87
2-3-2
Preventive Maintenance Procedures ......................................................... 2-87
2-3-2A
Tools, Materials and Equipment Required .............................................. 2-87
2-3-2B
Routine Checks .................................................................................. 2-87
2-3-2C
Schedule of Checks ............................................................................ 2-87
Subject to Export Control, see Cover Page for details.
iii
PARAGRAPH
PAGE
CHAPTER 2 - OPERATING INSTRUCTIONS (cont)
2-4
Operation Under Usual Conditions ................................................................ 2-88
2-4-1
Turn-On Procedure ................................................................................. 2-88
2-4-2
Screen Warnings and Cautions ................................................................. 2-90
2-5
Operating Procedures .................................................................................. 2-91
2-5-1
Introduction ............................................................................................ 2-91
2-5-2
Typical Vehicle Installation Test ............................................................... 2-92
2-5-3
Advanced Vehicle Installation Testing ....................................................... 2-96
2-5-4
Measuring SWR ...................................................................................... 2-97
2-5-5
Measuring DTF (Distance to Fault) ........................................................... 2-102
2-5-6
Measuring Reverse Power........................................................................ 2-108
2-5-7
Loading Software using USB Memory Device ............................................. 2-112
CHAPTER 3 - MAINTENANCE
3-1
Service Upon Receipt .................................................................................. 3-1
3-1-1
Service Upon Receipt of Material .............................................................. 3-1
3-1-1A
Unpacking .......................................................................................... 3-1
3-1-1B
Checking Unpacked Equipment ............................................................ 3-1
3-1-2
Preliminary Servicing and Adjustment of Equipment .................................... 3-2
3-2
Troubleshooting .......................................................................................... 3-3
3-3
Maintenance Procedures .............................................................................. 3-7
3-3-1
Battery Recharging ................................................................................. 3-7
3-3-2
Battery Replacement ............................................................................... 3-8
3-3-3
Fuse Replacement .................................................................................. 3-11
3-3-4
Handle Replacement ............................................................................... 3-14
3-3-5
Bumper Replacement .............................................................................. 3-16
3-4
Preparation for Storage or Shipment ............................................................. 3-17
3-4A
Packaging ............................................................................................ 3-17
3-4B
Environment ........................................................................................... 3-17
CHAPTER 4 - OPTIONS
4-1
General ..................................................................................................... 4-1
4-2
Installing Options ........................................................................................ 4-2
4-3
Spectrum Analyzer Option (35000010) ........................................................... 4-3
4-3-1
Spectrum Analyzer Screen ....................................................................... 4-4
4-3-2
Spectrum Analyzer Screen Features and Functions .................................... 4-5
4-4
Oscilloscope Option (35000001) ................................................................... 4-15
4-4-1
Oscilloscope Screen ............................................................................... 4-15
4-4-2
Oscilloscope Screen Features and Functions ............................................. 4-16
4-5
Tracking Generator Option (35000070) .......................................................... 4-23
4-5-1
Tracking Generator Screen ...................................................................... 4-23
4-5-2
Tracking Generator Screen Features and Functions .................................... 4-24
4-6
P25 Option (35000100) ................................................................................ 4-31
4-6-1
P25 Mini-Meter ....................................................................................... 4-31
4-6-2
P25 Mini-Meter Features and Functions ..................................................... 4-32
4-6-3
Digital Receive (P25) Screen Features and Functions ................................. 4-33
4-7
DMR Option (35000200) ............................................................................... 4-35
4-7-1
DMR Mini-Meter ...................................................................................... 4-35
4-7-2
DMR Mini-Meter Features and Functions ................................................... 4-36
4-7-3
Digital Receive (DMR) Screen Features and Functions ................................ 4-37
4-8
NXDN Option (35000400) ............................................................................. 4-41
4-8-1
NXDN Mini-Meter .................................................................................... 4-41
4-8-2
NXDN Mini-Meter Features and Functions .................................................. 4-42
4-8-3
Digital Receive (NXDN) Screen Features and Functions .............................. 4-43
Subject to Export Control, see Cover Page for details.
PARAGRAPH
PAGE
CHAPTER 4 - OPTIONS (cont)
4-9
dPMR Option (35000300) ............................................................................. 4-45
4-9-1
dPMR Mini-Meter .................................................................................... 4-45
4-9-2
dPMR Mini-Meter Features and Functions .................................................. 4-46
4-9-3
Digital Receive (dPMR) Screen Features and Functions .............................. 4-47
4-10
ARIBT98 Option (35000500) ......................................................................... 4-49
4-10-1
ARIBT98 Mini-Meter ................................................................................ 4-49
4-10-2
ARIBT98 Mini-Meter Features and Functions .............................................. 4-50
4-10-3
Digital Receive (ARIBT98) Screen Features and Functions .......................... 4-51
4-11
Scripting Option (35000060) ......................................................................... 4-53
4-11-1
Scripts Screen ........................................................................................ 4-53
4-11-2
Scripts Screen Features and Functions ..................................................... 4-54
4-11-3
Transfer Scripts to the 3500 / 3500A ......................................................... 4-55
4-11-4
Copy Scripts with Unit Copy Screen .......................................................... 4-57
4-11-5
General Scripting Commands ................................................................... 4-58
4-11-6
Scripting Flowcharts................................................................................ 4-59
APPENDICES
A
Connector Pin-Out Tables ............................................................................ A-1
A-1
I/O Connectors ....................................................................................... A-1
A-2
AUDIO Connector Pin-Out Table ............................................................... A-3
A-3
REMOTE Connector Pin-Out Table ............................................................ A-5
B
Abbreviations ............................................................................................ B-1
C
Remote Operation ....................................................................................... C-1
INDEX
LIST OF ILLUSTRATIONS / TABLES
Subject to Export Control, see Cover Page for details.
v
LIST OF ILLUSTRATIONS
TITLE
PAGE
Controls, Connectors and Indicators
2-1
Comm Breakout Box Connectors
2-4
Menu / Screen Hierarchy
2-5
LIST OF TABLES
TITLE
PAGE
3500 I/O Connectors
A-1
3500A I/O Connectors
A-2
3500 AUDIO Connector Pin-Out Table
A-3
3500A AUDIO Connector Pin-Out Table
A-4
3500 REMOTE Connector Pin-Out Table
A-5
3500A REMOTE Connector Pin-Out Table
A-6
SERVICE UPON RECEIPT OF MATERIAL
Subject to Export Control, see Cover Page for details.
vii
Unpacking
Special-design packing material inside this shipping carton provides maximum protection for the
3500 / 3500A. Avoid damaging the carton and packing material during equipment unpacking. Use
the following steps for unpacking the 3500 / 3500A.
● Cut and remove the sealing tape on the carton top and open the carton.
● Grasp the 3500 / 3500A transit case firmly, while restraining the shipping carton, and lift the
equipment and packing material vertically and place the 3500 / 3500A transit case and end cap
packing on a suitable flat, clean and dry surface.
● Remove the protective plastic bag from the 3500 / 3500A transit case. Place protective plastic
bag and end cap packing material inside shipping carton. Store the shipping carton for future use
should the 3500 /3500A need to be returned.
Checking Unpacked Equipment
● Inspect the equipment for damage incurred during shipment. If the equipment has been damaged,
report the damage to Aeroflex.
● Check the equipment against the packing slip to see if the shipment is complete. Report all
discrepancies to Aeroflex.
Subject to Export Control, see Cover Page for details.
Checking Unpacked Equipment (cont)
STANDARD ITEMS
DESCRIPTION
PART NUMBER
QTY
MODEL
3500 Communications Test Set
1
3500 ONLY
3500A Communications Test Set
1
3500A ONLY
Adapter (BNC-F to TNC-M)
23758 (2200-0410-700)
5
3500 / 3500A
Antenna (BNC) (50 MHz)
9149 (1201-7617-001)
1
3500A ONLY
Antenna (BNC) (150 MHz)
9145 (1201-7616-801)
1
3500A ONLY
Antenna (BNC) (450 MHz)
9147 (1201-7616-901)
1
3500A ONLY
Antenna (BNC) (800 MHz)
9143 (1201-7616-001)
1
3500A ONLY
Cable (BNC) (M-M) (48 in)
62368 (6041-4284-400)
2
3500 / 3500A
Cable (TNC) (M-M) (48 in)
62398 (6041-5680-800)
1
3500 / 3500A
Case, Accessory
5763 (1000-6200-800)
1
3500 ONLY
Case, Accessory
5762 (1000-6200-700)
1
3500A ONLY
Case, Soft-Sided Carrying
10191 (1412-0006-006)
1
3500 ONLY
Case, Soft-Sided Carrying
10192 (1412-0006-007)
1
3500A ONLY
Comm Breakout Box
64598 (7005-6242-900)
1
3500 / 3500A
External DC Power Supply
67374 (7110-6200-200)
1
3500 / 3500A
Fuse, Spare (5 A, 32 Vdc, Type F)
56080 (5106-0000-057)
2
3500 / 3500A
Handset
64592 (7005-6240-200)
1
3500 ONLY
Handset Cable
62403 (6041-6280-000)
1
3500 ONLY
Handset
64606 (7005-6244-700)
1
3500A ONLY
Manual, Getting Started (Paper)
6107 (1002-6200-8P0)
1
3500 / 3500A
Manual, Operation/ICW (CD)
6105 (1002-6200-2C0)
1
3500 / 3500A
Power Cable (AC)
62302 (6041-0001-000)
1
3500 ONLY
Power Cable (AC) (3-wire leads)
27516 (23424/159)
1
3500A ONLY
Power Cable (AC) (Continental Europe)
27480 (23422/007)
1
3500A ONLY
Power Cable (AC) (North America)
27478 (23422/005)
1
3500A ONLY
Power Cable (AC) (UK)
27477 (23422/002)
1
3500A ONLY
Power Cable (DC Cigarette Lighter)
62404 (6041-6281-400)
1
3500 / 3500A
Short-Open-Load VSWR Calibrator (TNC)
38245 (2901-0000-054)
1
3500 / 3500A
USB Flash Drive (1 GB)
67327 (7110-1100-600)
1
3500A ONLY
Subject to Export Control, see Cover Page for details.
ix
Checking Unpacked Equipment (cont)
STANDARD ITEMS
Adapter (BNC-F to TNC-M)
(23758) (2200-0410-700)
Antenna (BNC) (50 MHz)
(9149) (1201-7617-001)
Antenna (BNC) (150 MHz)
(9145) (1201-7616-801)
Antenna (BNC) (450 MHz)
(9147) (1201-7616-901)
Antenna (BNC) (800 MHz)
(9143) (1201-7616-001)
BNC Cable (M-M) (48 in)
(62368) (6041-4284-400)
TNC Cable (M-M) (48 in)
(62398) (6041-5680-800)
Accessory Case (3500)
(5763) (1000-6200-800)
Subject to Export Control, see Cover Page for details.
Checking Unpacked Equipment (cont)
STANDARD ITEMS
Accessory Case (3500A)
(5762) (1000-6200-700)
Soft-Sided Carrying Case
(10191) (1412-0006-006)
Soft-Sided Carrying Case
(10192) (1412-0006-007)
Comm Breakout Box
(64598) (7005-6242-900)
External DC Power Supply
(67374) (7110-6200-200)
Spare Fuse (5 A, 32 Vdc, Type F)
(56080) (5106-0000-057)
Handset (3500)
(64592) (7005-6240-200)
Handset Cable (3500)
(62403) (6041-6280-000)
Subject to Export Control, see Cover Page for details.
xi
Checking Unpacked Equipment (cont)
STANDARD ITEMS
Handset (3500A)
(64606) (7005-6244-700)
Getting Started Manual
(6107) (1002-6200-8P0)
Operation / ICW Manual
(61105 (1002-6200-2C0)
AC Power Cable
(62302) (6041-0001-000)
Power Cable (AC) (3 wire leads)
(27516) (23424/159)
Power Cable (AC) (Continental Europe)
(27480) (23422/007)
Power Cable (AC) (North America)
(27478) (23422/005)
Power Cable (AC) (UK)
(27477) (23422/002)
Subject to Export Control, see Cover Page for details.
Checking Unpacked Equipment (cont)
STANDARD ITEMS
Power Cable (DC Cigarette Lighter)
(62404) (6041-6281-400)
VSWR Calibrator (TNC)
(38245) (2901-0000-054)
USB Flash Drive (1 GB)
(67327) (7110-1100-600)
Subject to Export Control, see Cover Page for details.
xiii
Checking Unpacked Equipment (cont)
OPTIONAL ITEMS
(These optional items may be included if ordered)
DESCRIPTION
PART NUMBER
QTY
MODEL
Antenna (BNC) (50 MHz)
9149 (1201-7617-001)
1
3500 ONLY
Antenna (BNC) (150 MHz)
9145 (1201-7616-801)
1
3500 ONLY
Antenna (BNC) (450 MHz)
9147 (1201-7616-901)
1
3500 ONLY
Antenna (BNC) (800 MHz)
9143 (1201-7616-001)
1
3500 ONLY
Attenuator (20 dB / 50 W)
Attenuator (20 dB / 50 W)
Adapter (N-F to BNC-F)
Adapter (N-M to TNC-M)
82559
38240 (2901-0000-049)
23770 (2200-0412-800)
23766 (2200-0412-400)
1
1
1
3500 / 3500A
Attenuator (20 dB / 150 W)
Attenuator (20 dB / 150 W)
Adapter (N-F to BNC-F)
Adapter (N-M to BNC-F)
82560
38242 (2901-0000-051)
23770 (2200-0412-800)
20327 (2113-0000-004)
1
1
1
3500 / 3500A
Battery, Spare
67076 (7020-0012-500)
1
3500 / 3500A
Case, Transit
10242 (1412-6200-500)
1
3500 / 3500A
Desk Top Stand
63656 (6500-5681-000)
1
3500 / 3500A
Directional Coupler (20 to 200 MHz)
Directional Coupler (20 to 200 MHz)
Attenuator (10 dB)
Adapter (N-M to BNC-F)
Cable (BNC) (M-M) (16 in)
63964
47290 (4100-0900-000)
38255 (2901-0401-010)
20327 (2113-0000-004)
62405 (6041-6282-000)
1
1
2
2
3500 / 3500A
Flip Cover
63966 (7001-6242-100)
1
3500 / 3500A
Maintenance Manual (CD)
6108 (1002-6201-4C0)
1
3500 / 3500A
Tripod
67474 (7112-8102-500)
1
3500 / 3500A
Tripod and Stand with Dolly
Tripod
Tripod Stand
Dolly
82553
67474 (7112-8102-500)
63659 (6500-5881-100)
6361 (1005-1000-000)
1
3500 / 3500A
Subject to Export Control, see Cover Page for details.
Checking Unpacked Equipment (cont)
OPTIONAL ITEMS
Antenna (BNC) (50 MHz)
(9149) (1201-7617-001)
Antenna (BNC) (150 MHz)
(9145) (1201-7616-801)
Antenna (BNC) (450 MHz)
(9147) (1201-7616-901)
Antenna (BNC) (800 MHz)
(9143) (1201-7616-001)
20 dB / 50 W Attenuator
(38240) (2901-0000-049)
20 dB / 150 W Attenuator
(38242) (2901-0000-051)
Adapter (N-M to TNC-M)
(23766) (2200-0412-400)
Adapter (N-M to BNC-F)
(20327) (2113-0000-004)
Adapter (N-F to BNC-F)
(23770) (2200-0412-800)
Spare Battery
(67076) (7020-0012-500)
Subject to Export Control, see Cover Page for details.
xv
Checking Unpacked Equipment (cont)
OPTIONAL ITEMS
Transit Case
(10242) (1412-6200-500)
Directional Coupler
(47290) (4100-0900-000)
10 dB Attenuator
(38255) (2901-0401-010)
BNC Cable (M-M) (16 in)
(62405) (6041-6282-000)
Desk Top Stand
(63656) (6500-6242-100)
Flip Cover
(63966) (7001-6242-100)
Maintenance Manual
(6108) (1002-6201-4C0)
Tripod
(67474) (7112-8102-500)
Subject to Export Control, see Cover Page for details.
Checking Unpacked Equipment (cont)
OPTIONAL ITEMS
Tripod / Stand / Dolly
(67474) (7112-8102-500) / (63659) (6500-5881-100) /
(6361) (1005-1000-000)
CHAPTER 1 - INTRODUCTION
Subject to Export Control, see Cover Page for details.
1-1
1-1.
GENERAL INFORMATION
A.
Scope
Type of Manual:
Operation Manual
Equipment Name and Model Number:
3500 / 3500A Communications Test Set
Purpose of Equipment:
The 3500 / 3500A Communications Test Set is used for
testing radios and related equipment.
B.
Nomenclature Cross-Reference List
COMMON NAME
OFFICIAL NOMENCLATURE
3500 / 3500A
3500 / 3500A Communications Test Set
Test Set or Unit
3500 / 3500A Communications Test Set
Subject to Export Control, see Cover Page for details.
1-2.
EQUIPMENT CAPABILITIES AND FEATURES
The 3500 / 3500A is a Handheld Communications Test Set for Radio installation testing. The 3500 /
3500A is capable of measuring high power, up to 200 W, as well as fault finding for antennas, power
amplifiers and interconnects. The 3500 / 3500A meets the needs of a variety of vehicular radios, as
well as commercial radio applications.
The 3500 / 3500A is designed for ease of use, portability, reliability and long service life. The 3500 /
3500A may also be used for bench testing in the General Communications environment.
Power is derived from an internal battery. For DC input, the DC IN Connector is provided for battery
charging, bench operation or servicing.
The 3500 / 3500A and supplied accessories are stored in a Soft Carrying Case or a Transit Case.
A.
Capabilities
Capabilities
RF Receiver Testing - Up to 1 GHz bandwidth; AM, FM, frequency and level measurements.
RF Generator Testing - Up to 1 GHz bandwidth; AM, FM, 1 kHz / 150 Hz and external
modulation sources.
RF Power Meter - 20 W intermittent duty cycle; 200 W with an external attenuator.
VSWR measurements.
Simple operation with few key strokes and textual displays.
Large LCD Display with user adjustable Backlight and Contrast.
Self Test and Diagnostics for internal validation and testing.
Internal Battery allows 6 hours intermittent use, 5 hours continuous use before recharge.
Automatic power shutdown after approximately 5 to 20 minutes (selectable) of non-use when
AC power is not connected.
Compact and lightweight enough to allow for one person operation.
Subject to Export Control, see Cover Page for details.
1-3
B.
Features
Features
System Menu
Duplex Test Screen
Receiver Test Screen
Transmitter Test Screen
ANT-Cable Test Screen
Audio Function Generator Test Screen
Meters Menu
SINAD Meter Screen
Distortion Meter Screen
AF Counter Screen
Audio Level Meter Screen
Self Test Menu
Self Test Screen
Diagnostic Screen
Calibration Screen
Utilities Menu
Annunciator Screen
Remote Screen
Version Screen
Date/Time Screen
HW Config Screen
Options Screen
USB Manager Screen
Unit Copy Screen
Optional Features
Spectrum Analyzer Screen
Oscilloscope Screen
Tracking Generator
P25 Test
DMR
NXDN
dPMR
ARIBT98
Scripting
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA
NOTE
• Where specified resolution exceeds specified accuracy, the specified
resolution takes precedence.
• Accuracy and resolution stated in percentages are referenced to the
measured or selected value.
• All RF characteristics are referenced to 50 Ω.
• Allow warm-up period of at least 5 minutes.
• Received (input) signal modulation bandwidth does not exceed selected
receiver IF bandwidth.
• Specifications are subject to change without notice.
RF GENERATOR
PORT INPUT PROTECTION
ANT Port: ............................................................................................................. +20 dBm
SWR Port: ............................................................................................................ +20 dBm
T/R Port: .......................................................................................+44 dBm (Thermal alarm)
FREQUENCY
Range: ......................................................................................................... 2 to 1000 MHz
Accuracy: ............................................................................................... Same as Timebase
Resolution: ................................................................................................................. 1 Hz
OUTPUT LEVEL RANGE (TNC FEMALE)
T/R Connector (dBm / μV): .................................................. -50 to -120 dBm / 707.1 to 0.2 μV
ANT Connector (dBm / μV): ................................................. -30 to -90 dBm / 7071.1 to 7.1 μV
SWR Connector (dBm / μV): ............................................ -5 to -65 dBm / 125743.3 to 125.7 μV
Level Accuracy: ......................................................................................................... ±2 dB
±3 dB (<-100 dBm)
Level Resolution: ....................................................................1 dB / 0.1 μV (1 dB Step Size)
CONNECTOR VSWR
ANT Connector: .......................................................................................................<1.5 : 1
T/R Connector: ...................................................................................................... <1.25 : 1
SWR Connector: ......................................................................................................<1.5 : 1
SSB PHASE NOISE: .......................................................................... -80 dBc/Hz at 20 kHz offset
SPURIOUS
Harmonics: ............................................................................................................. -30 dBc
Non-Harmonics: .................... -40 dBc (>±20 kHz Offset from Carrier) in Band (2 MHz to 1 GHz)
RESIDUAL FM: .............................................................................. <60 Hz in 300 Hz to 3 kHz BW
RESIDUAL AM: ................................................................................. <5% in 300 Hz to 3 kHz BW
Subject to Export Control, see Cover Page for details.
1-5
1-3.
EQUIPMENT DATA (cont)
RF GENERATOR MODULATION - FM
Modulation Frequency (Rate) - AM and FM:
Range: ..................................................................................................... 0 Hz to 20 kHz
Resolution: .......................................................................................................... 0.1 Hz
Accuracy: ............................................................................................... Timebase ±2 Hz
Modulation Waveforms - AM and FM ............................................................ Sine, DCS, DTMF
FM Deviation Range: ........................... Off, 0 Hz to 100 kHz (AFGEN1 and AFGEN2 selectable)
Total Harmonic Distortion: .............. 3% (1000 Hz Rate, >2 kHz Deviation, 300 Hz to 3 kHz BPF)
FM Deviation Resolution: ........................................................................................... 10 Hz
FM Deviation Accuracy: .............................. ±10% (2 to 50 kHz deviation, 150 Hz to 5 kHz rate)
MIC IN (3500):
Microphone Input: ..................................................................................... 1 to 30 mVrms
FM Input Frequency Range: ................................................................... 400 Hz to 1.2 kHz
FM Input Slope: .................................................. Positive voltage yields positive deviation
MIC IN (3500A):
Microphone Input: .......................................... 2 to 15 mVrms (8 mVrms nominal) (Range 1)
35 to 350 mVrms (100 mVrms nominal) (Range 2)
2 to 32 mVrms (20 mVrms nominal) (Range 3)
FM Input Frequency Range: ...................................................................... 300 Hz to 3 kHz
FM Deviation: .................................................................................... Off, 0 Hz to 80 kHz
FM Modulation Accuracy: ........................................................... ±20% (300 Hz to 1.2 kHz)
±30% (>1.2 kHz)
FM Input Slope: .................................................. Positive voltage yields positive deviation
Ext AUDIN Input:
Switchable Loads: ................................................................. 150 Ω, 600 Ω, High Z (3500)
150 Ω, 600 Ω, 1 KΩ, High Z (3500A)
Input Levels: ............................................................................................. 0.05 to 3 Vrms
FM Input Frequency Range: ...................................................................... 300 Hz to 5 kHz
FM Input Level Sensitivity: .................................... 1 kHz / 35 mVrms nominal (High Z Load)
FM Input Slope: .................................................. Positive voltage yields positive deviation
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA (cont)
RF GENERATOR MODULATION - AM
Modulation Frequency (Rate) - AM and FM:
Range: ..................................................................................................... 0 Hz to 20 kHz
Resolution: .......................................................................................................... 0.1 Hz
Accuracy: ............................................................................................... Timebase ±2 Hz
AM Modulation:
Range: ............................................... OFF, 0% to 100% (AFGEN1 and AFGEN2 selectable)
Resolution: ............................................................................................................ 0.1%
Accuracy: ............................... 10% of setting, 150 Hz to 5 kHz rate, 10% to 90% Modulation
Total Harmonic Distortion: ................3% (20% to 90% mod, 1000 Hz rate, 300 Hz to 3 kHz BPF)
Ext AUDIN Input:
Switchable Loads: ................................................................. 150 Ω, 600 Ω, High Z (3500)
150 Ω, 600 Ω, 1 KΩ, High Z (3500A)
Input Levels: ............................................................................................. 0.05 to 3 Vrms
AM Input Frequency Range: ...................................................................... 300 Hz to 5 kHz
AM Input Level Sensitivity: ........................................ 1% / 35 mVrms nominal (High Z Load)
MIC IN (3500):
AM Input Frequency Range: ................................................................... 400 Hz to 1.2 kHz
MIC IN (3500A):
Microphone Input: .......................................... 2 to 15 mVrms (8 mVrms nominal) (Range 1)
35 to 350 mVrms (100 mVrms nominal) (Range 2)
2 to 32 mVrms (20 mVrms nominal) (Range 3)
AM Input Frequency Range: ...................................................................... 300 Hz to 3 kHz
AM Modulation: .................................................................................. Off, 0 Hz to 80 kHz
AM Modulation Accuracy: ........................................................... ±20% (300 Hz to 1.2 kHz)
±30% (>1.2 kHz)
Subject to Export Control, see Cover Page for details.
1-7
1-3.
EQUIPMENT DATA (cont)
AUDIO GENERATORS (AFGEN1 AND AFGEN2)
NOTE
If two sources are selected, they are summed together. AFGEN1 and AFGEN2
may be routed to the external AUD Out connection on the handset.
Specifications are for each FGEN individually.
Frequency Range: ......................................................................................... 30 Hz to 5 kHz
0 to 20 kHz (operational)
Frequency Resolution: .............................................................................................. 0.1 Hz
Frequency Accuracy: ................................................................................... Timebase ±2 Hz
Output Level:
Load Impedance: ................................................................................................... 600 Ω
Audio Level Out: ....................................................................................... 0 to 1.57 Vrms
Resolution: ..................................................................................................... 0.01 Vrms
Accuracy: .............................................................................................................. ±10%
Distortion: ................................................................. <3% (1 kHz rate, sine 300 Hz to 3 kHz)
HANDSET (PROVIDED) OR H-250 HANDSET WITH ADAPTER
Frequency: .............................................................................................. 300 Hz to 1.2 kHz
Input Level: .................................................................................................. 0.03 to 8 Vrms
PTT OPERATION
NOTE
PTT ON / OFF changes between TRANSMITTER TEST and RECEIVER TEST.
PTT ON: ............................................................................................................. Low, GND
PTT OFF: ......................................................................................... High, Open with Pullup
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA (cont)
RF RECEIVER
FREQUENCY RANGE: .......................................................................................... 2 to 1000 MHz
ACCURACY: ............................................................................................................... Timebase
RESOLUTION: ................................................................................................................... 1 Hz
INPUT AMPLITUDE
Minimum Input Level (Audio Sensitivity):
ANT Connector: ................. -80 dBm typical, 10 dB SINAD / 22.4 μV (-110 dBm with Preamp)
T/R Connector: ..................................................... -40 dBm typical, 10 dB SINAD, 2236 μV
Useable Input Level Range (Receiver Measurements):
ANT Connector: ..................... -60 to -10 dBm (RF Error, Distortion, Modulation, AF Counter)
-80 to -10 dBm with Preamp ON
-90 to -10 dBm (RSSI)
-110 to -10 dBm with Preamp ON
Minimum Input Level (Receiver Measurements)
T/R Connector: ............................... -20 dBm (RF Error, Distortion, Modulation, AF Counter)
-50 dBm (RSSI)
Maximum Input Level:
ANT Connector: ..................................................... +20 dBm for 10 seconds, Alarm sounds
T/R Connector: ......................................................................................... +37 dBm (AM)
+43 dBm (FM)
NOTE
Overtemp Alarm trips if the power is left on too long and the temperature of the
Power Termination gets too hot.
FM Demod Output (AUD OUT):
IF BW: ........................................... 5, 6.25, 8.33, 10, 12.5, 25, 30, 100 and 300 kHz IF BW
Audio Filters BW: .................................. C-Wt BP, CCITT BP, NONE, 15 kHz LP, 300 Hz LP,
300 Hz HP, 5 kHz LP, 300 Hz to 5 kHz BP, 300 Hz to 3 kHz BP,
300 Hz to 20 kHz BP and 3 kHz LP
Level Sensitivity: ...................................................... (3 Vrms/kHz Dev) / IF BW (kHz) ±15%
AM Demod Output (AUD OUT):
IF BW: ................................................................... 5, 6.25, 8.33, 10, 12.5, 25 and 30 kHz
Audio Filters BW: .................................. C-Wt BP, CCITT BP, NONE, 15 kHz LP, 300 Hz LP,
300 Hz HP, 5 kHz LP, 300 Hz to 5 kHz BP, 300 Hz to 3 kHz BP,
300 Hz to 20 kHz BP and 3 kHz LP
Level Sensitivity: ............................................................................ 7 mVrms / %AM ±15%
Speaker Output: ........................... 75 dBa minimum at 0.5 m, 600 to 1800 Hz, maximum volume
Volume Control: ........................................................................ Level Range, Scale 0 to 100
LO Emissions: ....................................................................................................... >-50 dBc
Quieted Channels: ........ 10 frequencies allowed between 2 and 999.999 MHz, quieted by ≤30 dB
Subject to Export Control, see Cover Page for details.
1-9
1-3.
EQUIPMENT DATA (cont)
DUPLEX
NOTE
Duplex Test is Receiver and Transmitter Tests simultaneously. Performance
parameters are the same as the independent Receiver and Transmitter Test
Screens.
RF TRANSMITTER TEST METERS
RF ERROR METER
Meter Operating Range: ........................................................................................ ±200 kHz
Resolution: ................................................................................................................. 1 Hz
Accuracy: ................................................................................................... Timebase ±2 Hz
RSSI METER (RF Power within Receiver IF BW)
Display Range / Units: ........................................................ -120 to +43 dBm (10 pW to 20 W)
-120 to +53 dBm (10 pW to 200 W) (Ext Atten set to 20 dB)
Useable Meter Reading - RF Level Range:
ANT Connector: ....................................................................................... -90 to -10 dBm
-110 to -10 dBm (Preamp ON)
T/R Connector: ........................................................................................ -50 to +43 dBm
Resolution: .......................................................................................................... 0.01 dBm
Accuracy: ................................................................................................................. ±3 dB
RF POWER METER (Broadband RF Power into T/R Connector)
Display Range / Units: .................................................................... 0 to +43 dBm (0 to 20 W)
0 to +53 dBm (0 to 200 W) (Ext Atten set to 20 dB)
Minimum Input Level (w/ dBm): .................................................................. 0.10 W / +20 dBm
Maximum Input Level: ............................................... +43 dBm / 20 W for 10 minutes at +25°C
or until Thermal Alarm sounds (whichever occurs first)
Alarms: ................................................................ +44 dBm for 5 seconds ON, 5 minutes OFF
or until Thermal Alarm sounds (whichever occurs first)
Meter Modes: ............................................................................................... Average Power
Display Units: .................................................................................... W or dBm (selectable)
Resolution: ........................................................................................... 0.01 (W), 0.1 (dBm)
Accuracy
No External Attenuator: .......................................................... ±1 dB for internal attenuator
With External Attenuator: ........................................... ±1 dB ± external attenuator accuracy
NOTE
When External Attenuator is selected, 20 dB is added to the measurements of
50 or 200 W.
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA (cont)
RF POWER METER (Broadband RF Power into T/R Connector) (cont)
External 20 dB Attenuator Accuracy
50 W Attenuator: ............................................................................................... ±0.75 dB
150 W Attenuator: ............................................................................................. ±0.50 dB
External 20 dB Attenuator Power Rating:
50 W Attenuator - 20 dB: ................................................................. 50 W average at 25°C
150 W Attenuator - 20 dB: ................................ 150 W average for temperatures up to 25°C,
linearly de-rated to 125 W at 55°C, horizontal
200 W peak for 30 seconds ON/ 5 minutes OFF at 25°C
FM DEVIATION METER
Meter Deviation Range: ........................................................................... 500 Hz to ±100 kHz
Meter Modes: ........................................................................... Peak+, Peak-, (Peak-Peak)/2
Resolution: ................................................................................................................. 1 Hz
Accuracy: ...................................................................... ±10% (500 Hz to 100 kHz Deviation)
±5% (1 to 10 kHz Deviation)
150 Hz and 1 kHz Rate
AM MODULATION METER
Meter Range: .................................................................................................... 5% to 100%
Meter Modes: ........................................................................... Peak+, Peak-, (Peak-Peak)/2
Resolution: ................................................................................................................... 1%
Accuracy: ................................ ±5% of reading, 1 kHz rate, 30% to 90% modulation, 3 kHz LPF
SWR MEASUREMENT
FREQUENCY
Range: ......................................................................................................... 2 to 1000 MHz
Calibration and Sweep Bandwidth:..................................... 2 to 1000 MHz, 0.1 MHz Resolution
SWR READING
Display Range: ................................................................................................. 1.00 to 7.00
Resolution: ................................................................................................................. 0.01
Accuracy: .........................................................±10% of SWR readings (calibrated) <300 MHz
±20% of SWR readings (calibrated) >300 MHz
DTF READING
Test Range: ...................................................................................... 3 to 328 ft (1 to 100 m)
Display Range: .................................................................................................. 40 to 400 ft
(Range is function of Frequency Span and Cable Velocity Factor and Cable Loss)
Accuracy: ................................................................................................................... ±3 ft
Subject to Export Control, see Cover Page for details.
1-11
1-3.
EQUIPMENT DATA (cont)
AUDIO METERS
AUDIO INPUT (EXT AUD IN) (BNC Input on Handset)
EXT AUD IN Input :
Frequency Range: ....................... 300 Hz to 10 kHz (1 kHz for SINAD and Distortion Meters)
Input Level (3500): ................................................................................. 50 to 1.5 mVrms
Input Level (3500A): .................................................................................... 0.2 to 5 Vp-p
SINAD METER
Measurement Sources: ......................................................................... EXT AUD IN, DEMOD
Audio Frequency Notch: ............................................................................................. 1 kHz
Reading Range: .................................................................................................. 0 to 40 dB
Resolution: .............................................................................................................. 0.1 dB
Accuracy: .............................................................. ±1.5 dB, reading >8 dB, <40 dB, ±1 Count
DISTORTION METER
Measurement Sources: ......................................................................... EXT AUD IN, DEMOD
Audio Frequency Notch: ............................................................................................. 1 kHz
Reading Range: ................................................................................................ 0% to 100%
Resolution: ................................................................................................................ 0.1%
Accuracy: ..................................................................... ±10%, reading >1%, <20%, ±1 Count
AF COUNTER
Input Dynamic Range:
FM: ........................... 15 Hz to 20 kHz (IF BW set appropriately for received modulation BW)
AM: ......................... 100 Hz to 10 kHz (IF BW set appropriately for received modulation BW)
Baseband Audio In: ............................................................................ 10 mVp-p to 5 Vp-p
Audio Input Range: ...................................................................................... 15 Hz to 20 kHz
Ext Audio Input: ................................................................................. 10 mVrms to 1.5 Vrms
Resolution: .............................................................................................................. 0.1 Hz
Accuracy: ................................................................................................................. ±1 Hz
AUDIO FREQUENCY LEVEL METER
Measurement Sources: .............................................................................. EXT AUD IN, DVM
Frequency Range: ..................................................................................... 200 Hz to <5 kHz
Input Level:
EXT AUD IN (3500):........................................................................ 10 mVrms to 1.5 Vrms
EXT AUD IN (3500A):.............................. 10 mVrms to 3 Vrms (x1), 1 Vrms to 30 Vrms (÷10)
DVM (3500): ............................................................................... 1 Vrms to 30 Vrms (÷20)
DVM (3500A): ........................................ 10 mVrms to 3 Vrms (x1), 1 Vrms to 30 Vrms (÷20)
Display Unit Resolution: .......................... 0.001 V, 0.001 mV, 0.001 dBμV, 0.001 dBm, 0.001 W
Accuracy: ............................................................................................... ±5% (EXT AUD IN)
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA (cont)
OSCILLOSCOPE (OPTIONAL)
Single Input Channels: ............................................................ DVM, Audio In, Internal Demod
Input Impedance:
DVM Input: ............................................................................................................ 1 MΩ
Audio I/O Input: .................................................................... 150 Ω, 600 Ω, High Z (3500)
150 Ω, 600 Ω, 1 KΩ, Divide-by-10, High Z (3500A)
Coupling:
DVM Input: ........................................................................................... AC, DC and GND
Audio I/O Input: ........................................................................................................ AC
FM Internal Demod: ................................................................................................... DC
AC Internal Demod: ................................................................................................... AC
Range:
DVM and Audio I/O Output: ................................ 10 mV/Div to 10 V/Div in a 1,2,5 sequence
FM Internal Demodulation: ............................ 0.1 kHz/Div to 50 kHz/Div in a 1,2,5 sequence
AM Internal Demodulation: ........................................................... 5%, 10%, 20%, 50%/Div
Vertical Accuracy: ................................................................ 10% of Full Scale (DC to 5 kHz)
Bandwidth: ............................................................................................................... 5 kHz
Horizontal Sweep:
Range: ...................................................................................... 0.5 ms/Div to 0.1 sec/Div
Accuracy: .............................................................................................. 3% of Full Scale
Trigger Source: .......................................................................... Auto or Normal (Internal)
Trigger Adjustment: .................................................................. Variable on Vertical Scale
Markers: ..................................................................................................... Two Markers
Displays Vertical Measurement (Voltage, kHz, % Modulation)
Displays Delta in Time between Markers
SPECTRUM ANALYZER (OPTIONAL)
Frequency:
Range: ................................................................................................... 2 MHz to 1 GHz
Span: ....................................................................... 10 kHz to 5 MHz in a 1,2,5 sequence
Windows: ................................................................................. Hanning, Flat Top, Rectangle
Vertical Scale: .................................................................................. 2, 5, 10, 15, 20 dB/Div
Marker Range: ................................................................ 1 kHz to 5 MHz in a 1,2,5 sequence
Marker Offset: ........................................................... ±1 kHz to 0.5 Span in a 1,2,5 sequence
Power Bandwidth Accuracy: ........................................... ±3 dB Typical (30 dB Signal to Noise)
Noise Floor: ................................................................. ±3 dB Typical (30 dB Signal to Noise)
Subject to Export Control, see Cover Page for details.
1-13
1-3.
EQUIPMENT DATA (cont)
TIMEBASE
STANDARD OSCILLATOR
Temperature Stability: .............................................................................. ±0.25 ppm at 25°C
±0.5 ppm over temperature range
Aging: ............................................................................................................. 1 ppm / year
Warmup Time: ...................................................................................................... 3 minutes
ENVIRONMENTAL / PHYSICAL
OVERALL DIMENSIONS: ................... 231 mm (9.1 in) (W), 285 mm (11.2 in) (L), 70 mm (2.8 in) (D)
WEIGHT: .................................................. 8.5 lbs.; 12 lbs with accessories and soft carrying case
TEMPERATURE
Storage: ...................................................................................................... -51°C to +71°C
NOTE
Battery must not be subjected to temperatures below -20°C, nor above +60°C.
Operation: ................................................................................................... -20°C to +50°C
NOTE
Battery is to be charged at 0°C to +45°C.
HUMIDITY
Storage: ....................................................................................... MIL-PRF-28800F, Class 2
Operation: .................................................................................... MIL-PRF-28800F, Class 2
ALTITUDE
Operation: .................................................................................... MIL-PRF-28800F, Class 2
SHOCK
Operation: .................................................................................... MIL-PRF-28800F, Class 2
BENCH HANDLING
Operation: .................................................................................... MIL-PRF-28800F, Class 2
VIBRATION
Operation: .................................................................................... MIL-PRF-28800F, Class 2
COMPLIANCE
USE: ...................................................................................................... Pollution Degree 2
EMC: ........................................................................................... MIL-PRF-28800F, Class 2
AC INPUT POWER
AC Input Voltage Range: ................................ 100 to 240 VAC, 1.5 A maximum, 47 Hz to 63 Hz
AC Input Voltage Fluctuation: ............................................. <10% of the nominal input voltage
Transient Overvoltage: .................................................... According to Installation Category II
Subject to Export Control, see Cover Page for details.
1-3.
EQUIPMENT DATA (cont)
AC-DC CONVERTER
Usage Environment: ................................................................ Indoor use, Pollution Degree 2
Operating Temperature: ................................................................................... 0°C to +40°C
Storage Temperature: ................................................................................... -20°C to +85°C
EMI: ........................................................................ EN55022 Class B, EN61000-3-2 Class D
Safety: ......................................... UL 1950, CSA 22.2 No. 234 and No.950, IEC 950/EN 60950
DC INPUT CONNECTOR (DC IN)
DC Input Voltage Range: ................................................................................... 11 to 32 Vdc
DC Power Input:
Maximum: .............................................................................................................. 55 W
Nominal:................................................................................................................ 25 W
DC Fuse Requirement: ........................................................................... 5 A, 32 Vdc, Type F
BATTERY
Battery Type: ....................................................................... Lithium Ion (Li Ion) Battery pack
NOTE
Battery must not be subjected to temperatures below -20°C, nor above +60°C.
Operation Time: ............................................................................... 5 hours continuous use
Charge Time: .......................................................................................................... 4 hours
NOTE
Battery is to be charged at 0°C to +45°C. Dead Battery (<10% capacity) is to
be charged for 20 minutes before operation on AC Power.
STATIC THERMAL CHARACTERISTICS
Ambient, Power ON, RF Power OFF: ............................................. <15°C rise after 30 minutes
Ambient, Power ON, RF Power ON: .............................................. <25°C rise after 30 minutes
Subject to Export Control, see Cover Page for details.
1-15
1-4.
PRINCIPLES OF OPERATION
The 3500 contains the following assemblies:
LCD
T/R
KEYPAD
RF
DIGITIZER
POWER
SUPPLY
BATTERY
MULTI-
FUNCTION
RF
SWR
ANT
REMOTE
DC IN
AUDIO
The Power Supply PCB Assy is responsible for supplying power to the internal modules
for operation and for charging the internal batteries.
The RF Digitizer PCB Assy converts the baseband signal to a modulated 10.5 MHz Tx IF
which is upconverted in the RF Assy to provide an RF Generator output. The Receive
signals are down-converted to 13 MHz and demodulated to baseband signals.
The Multi-Function PCB Assy includes the processors, FPGA and memory to send data
from the RF Digitizer PCB Assy through the Power PC to the ColdFire for display on the
LCD Display. Keyboard inputs are processed to provide instructions to the RF Assy.
The RF Assy consists of the RF Controller PCB Assy and the RF Converter PCB Assy.
The RF Converter PCB Assy converts the 10.5 MHz TX IF to the 2 MHz to 1 GHz RF and
from the 2 MHz to 1 GHz receiver input to the 13 MHz RX IF. The RF Converter PCB Assy
also contains the VSWR coupler and associated circuitry and the Power Termination. The
RF Controller PCB Assy provides the TCXO, LOs and digital circuitry necessary for
software control and for tuning and level control.
Subject to Export Control, see Cover Page for details.
1-4.
PRINCIPLES OF OPERATION (cont)
The 3500A contains the following assemblies:
LCD
T/R
AUDIO I/O
RF
DIGITIZER
POWER
SUPPLY
BATTERY
MULTI-
FUNCTION
RF
SWR
ANT
REMOTE
DC IN
KEYPAD
AUDIO
DVM
AUDIO IN
AUDIO OUT
The Power Supply PCB Assy is responsible for supplying power to the internal modules
for operation and for charging the internal batteries.
The RF Digitizer PCB Assy converts the baseband signal to a modulated 10.5 MHz Tx IF
which is upconverted in the RF Assy to provide an RF Generator output. The Receive
signals are down-converted to 13 MHz and demodulated to baseband signals.
The Multi-Function PCB Assy includes the processors, FPGA and memory to send data
from the RF Digitizer PCB Assy through the Power PC to the ColdFire for display on the
LCD Display. Keyboard inputs are processed to provide instructions to the RF Assy.
The RF Assy consists of the RF Controller PCB Assy and the RF Converter PCB Assy.
The RF Converter PCB Assy converts the 10.5 MHz TX IF to the 2 MHz to 1 GHz RF and
from the 2 MHz to 1 GHz receiver input to the 13 MHz RX IF. The RF Converter PCB Assy
also contains the VSWR coupler and associated circuitry and the Power Termination. The
RF Controller PCB Assy provides the TCXO, LOs and digital circuitry necessary for
software control and for tuning and level control.
The Audio I/O PCB Assy provides the DVM/Scope, Audio In and Audio Out signals to the
3500A Front Panel.
CHAPTER 2 - OPERATING INSTRUCTIONS
Subject to Export Control, see Cover Page for details.
2-1
062-006b
3500
AUDIO OUT
AUDIO IN
DVM
1
2
3
4
5
6
7
8
9
0
(3500A)
(3500)
14
15
16
17
18
19
10
11
12
13
7
8
9
1
5
3
2
4
6
20
22
21
(3500A ONLY)
2-1.
OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS
1
ANT Connector
2
T/R Connector
3
DC IN Connector
4
AUDIO Connector
5
SWR Connector
6
REMOTE Connector
7
Display (LCD)
8
Multi-Function Soft Keys
9
Number Keys
10
CONTRAST / • Key
11
BACKLIGHT / ± Key
12
CHARGE Indicator
13
POWER Key
14
POWER Indicator
15
FAULT Indicator
16
DOWN Key
17
LEFT Key
18
RIGHT Key
19
UP Key
20
DVM Connector
21
AUDIO IN Connector
22
AUDIO OUT Connector
Figure 2-1. Controls, Connectors and Indicators
Subject to Export Control, see Cover Page for details.
2-1.
OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont)
ITEM
DESCRIPTION
LEFT Key
Used to move the on-screen cursor from one frame to
another. Also used to move the on-screen cursor to the
next digit to the left in an edit field.
NOTE: The on-screen cursor moves in a fixed order.
This is to ensure that all frames and fields are
accessed in a predictable fashion.
RIGHT Key
Used to move the on-screen cursor from one frame to
another. Also used to move the on-screen cursor to the
next digit to the right in an edit field.
NOTE: The on-screen cursor moves in a fixed order.
This is to ensure that all frames and fields are
accessed in a predictable fashion.
UP Key
Used to move the on-screen cursor from one field to
another within a frame. Also used to increment an edit
field.
NOTE: The on-screen cursor moves in a fixed order.
This is to ensure that all frames and fields are
accessed in a predictable fashion.
DOWN Key
Used to move the on-screen cursor from one field to
another within a frame. Also used to decrement an edit
field.
NOTE: The on-screen cursor moves in a fixed order.
This is to ensure that all frames and fields are
accessed in a predictable fashion.
AUDIO Connector
Used for connection to the Microphone.
AUDIO IN Connector (3500A only)
Used to receive external modulation input, and as input
for the SINAD and Distortion Meters and AF Counter.
AUDIO OUT Connector (3500A only)
Used as output for Demod and Function Generators and
for Audio In signal output.
ANT Connector
Used for over-the-air tests.
BACKLIGHT / ± Key
Used for selecting the Backlight Adjust Mode. The
UP or DOWN Keys may be used to adjust the
Backlight level to one of 25 different settings.
Used to change between positive (+) and negative (-)
values during data entry.
CHARGE Indicator
Illuminates when external DC power is applied:
GREEN
Battery at Full Charge
YELLOW
Battery is Charging
RED
Battery Charge Failure
CONTRAST / • Key
Used for selecting the Contrast Adjust Mode. The
UP or DOWN Keys may be used to adjust the
Contrast level to one of 25 different settings.
Used to add a decimal point (•) to values during data
entry.
Subject to Export Control, see Cover Page for details.
2-3
2-1.
OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont)
ITEM
DESCRIPTION
DC IN Connector
Used for operation of the 3500 / 3500A or battery
charging.
Display (LCD)
Used for viewing menus and screens. Soft Key boxes
appear at the bottom of the menus/screens.
DVM Connector (3500A only)
Provides DC coupled input for the Audio Level Meter
and the Oscilloscope (Option) functions.
FAULT Indicator
Illuminates when a fault exists in the 3500 / 3500A:
YELLOW
Caution Condition exists
RED
Warning Condition exists
Multi-Function Soft Keys
Five Soft Keys are provided. The legends are
displayed in boxes at the bottom of the Display.
Number Keys
Used for data entry or to select a numbered item.
Alternate key functions are utilized when selecting file
names in the Save Screen.
POWER Indicator
Illuminates when the 3500 / 3500A is powered up.
POWER Key
Used for powering the 3500 / 3500A ON and OFF.
REMOTE Connector (External I/O)
Used for communicating with external equipment.
SWR Connector
Used for measuring the VSWR of Antenna systems.
Also used as a transmit signal output.
T/R Connector
Used for high power direct connection to radio
equipment.
Subject to Export Control, see Cover Page for details.
2-1.
OPERATOR’S CONTROLS, INDICATORS AND CONNECTORS (cont)
Figure 2-2. Comm Breakout Box Connectors
CONNECTOR
FUNCTION
USB HOST Connector
Used to connect to external unit.
RS-232 Connector
Used to connect to RS-232 external unit.
ETHERNET Connector
Used to connect to an external unit.
REMOTE Connector
Used for communicate with the 3500 / 3500A.
Subject to Export Control, see Cover Page for details.
2-5
2-2.
OPERATION SCREENS AND MENU CONFIGURATIONS
SYSTEM *M ENU
DISTORTION
SINAD
AF *COUNTER
AUDIO*LEVEL*M ETER
UTILITIES *M ENU
SELF*TEST *M ENU
AUDIO
RECEIVER
DUPLEX
TRANSM ITTER
ANT-CABLE *TEST
DIAGNOSTIC
SELF*TEST
CALIBRATION
OPTIONS
HW*CONFIG
USB*M ANAGER
REM OTE
ANNUNCIATOR
VERSION
DATE */*TIM E
M ETERS*M ENU
UNIT*COPY
Figure 2-3. Menu / Screen Hierarchy
Subject to Export Control, see Cover Page for details.
2-2-1.
SCREEN ICONS
The screen icons are displayed at the top left of the test screens.
41 20 29
SCREEN FEATURE
FUNCTION
PPC CPU Usage
Displays the level of PPC usage.
When the PPC usage is 20% to 39%, the icon is displayed as vertical
bar.
When the PPC usage is 40% to 59%, the icon is displayed as two
vertical bars.
When the PPC usage is 60% to 79%, the icon is displayed as three
vertical bars.
When the PPC usage is 80% to 100%, the icon is displayed as four
vertical bars. The icon blinks when the PPC usage is >90%.
NUMBER
Internal Temperature
Displays the current FPGA temperature in °C. (Example: 41)
When the internal temperature is <-20°C or >85°C, a warning message
is displayed.
Flash Save Status
Displays the status of a save operation.
When the icon is fully drawn, all settings are currently saved to Flash.
Afer editing, the lower right half of the icon disappears until the
settings are saved to Flash.
Phase Loop Lock (PLL)
Displays the status of the Generator and Receiver Synthesizer Lock.
Under normal conditions, the icon is displayed as a square.
If the Generator becomes unlocked, a warning message is displayed
and a triangle shape is displayed (blinking) above the square icon.
If the Receiver becomes unlocked, a warning message is displayed
and a triangle shape is displayed (blinking) below the square icon.
Battery Level Indicator
Displays the percentage of the battery life remaining.
When the battery level is<20 (on a 0 to 100 scale) the battery level
icon blinks.
Subject to Export Control, see Cover Page for details.
2-7
2-2-1.
SCREEN ICONS (cont)
SCREEN FEATURE
FUNCTION
NUMBER
Battery Temperature
Displays the Battery temperature in °C. (Example: 20)
If the battery temperature is >53°C a warning message is displayed
and the battery level icon blinks.
ANT Connector Overload
Indicates if the ANT Connector is in overload mode.
If the ANT Connector is in overload mode, a warning message is
displayed and the lower half of the icon blinks.
T/R Connector Overload
Indicates if the T/R Connector is in overload mode.
If the T/R Connector is in overload mode, a warning message is
displayed and the lower half of the icon blinks.
SWR Connector Overload
Indicates if the SWR Connector is in overload mode.
If the SWR Connector is in overload mode, a warning message is
displayed and the lower half of the icon blinks.
NUMBER
RF Temperature
Displays the T/R Connector temperature in °C. (Example: 29)
The RF temperature increases when more RF power is dissipated.
AGC Compression
Displays the level of Receiver compression.
With no AGC compression the icon is displayed as a box.
When AGC is in compression, a message is displayed and the icon is
displayed as an hourglass.
DVM Overload
Displays the DVM Overload status.
When conditions are normal the icon is displayed as a triangle.
When an overload occurs, a message is displayed, the icon is
displayed as a lightening bolt inside a triangle and the icon blinks.
Subject to Export Control, see Cover Page for details.
2-2-2.
SYSTEM MENU
When the unit is powered ON, the System Menu is displayed, or when the Meters Menu, Self Test
Menu or Utilities Menu is displayed, press the F3 “System” Key to access the System Menu:
Meters
System
Selftest
Util
1 - DUPLEX TEST
2 - RECEIVER TEST
3 - TRANSMITTER TEST
4 - ANT-CABLE TEST
5 - AUDIO
SCREEN FEATURE
FUNCTION
1 - DUPLEX TEST
Displays the Duplex Test Screen (para 2-2-2A).
2 - RECEIVER TEST
Displays the Receiver Test Screen (para 2-2-2B).
3 - TRANSMITTER TEST
Displays the Transmitter Test Screen (para 2-2-2C).
4 - ANT-CABLE TEST
Displays the ANT-Cable Test Screen (para 2-2-2D).
5 - AUDIO
Displays the Audio Test Screen (para 2-2-2E).
F2 “Meters”
Displays the Meters Menu (para 2-2-3).
F3 “System”
Displays the System Menu (para 2-2-2).
F4 “Selftest”
Displays the Self Test Menu (para 2-2-4).
F5 “Util”
Displays the Utilities Menu (para 2-2-5).
Subject to Export Control, see Cover Page for details.
2-9
A.
Duplex Test Screen
When the System Menu is displayed, press the 1 Key to access the Duplex Test Screen:
Edit
Return
Hold
Setup
PTT on
DUPLEX TEST
Generator
Off
Receiver More
MH z: 40.000000
MH z: 40.000000
Port: T/R
Port: T/R
Level: -70 dBm Mod: FM 10k
Ext Attn dB: 0
AFBW: 0.3k HP
Modulator Freq FM Analog
Gen 1: On 1000.0 H z 6.25 kH z
Gen 2: On 150.0 H z 3.25 kH z
MIC: On 6.25 kH z
Ext Aud: Off Load: High Z
Volume:
100
Squelch:
-50 dBm
Speaker:
Audio In
AudOut:
Audio In
Save
Recall
41 20 29
(CTCSS)
Modulator Freq/Code FM DCS
Gen 1: Off 150.0 H z
3.50 kH z
Dcs: Non Inv 023
6.25 kH z
MIC: Off
0.00 kH z
Ext Aud: Off Load: High Z
Modulator FM DTMF
Gen 1: Off 150.0 H z 3.50 kH z
DTMF: Burst Trig Lo: 6.25 kH z
Seq: 0123456789 Hi: 6.25 kH z
Mark: 200 ms Space: 200 ms
(DCS) (DTMF)
SCREEN FEATURE
FUNCTION
Status (Generator)
Displays the status (On / Off) of the Generator.
MHz (Generator)
Used to select the signal generator frequency.
Range:
2.000000 to 1000.000000 MHz in 0.000001 MHz
increments
Port (Generator)
Used to select the signal generator output connector.
Select:
Ant, T/R or SWR
Receiver More
Ext Attn dB: 0.0
Preamp: Auto
Subject to Export Control, see Cover Page for details.
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
Level (Generator)
Used to select the signal generator output level.
The Generator Output Level Units can be toggled between dBm and
μV.
Select:
Ant
-90 to -30 dBm in 1 dB increments
T/R
-120 to -50 dBm in 1 dB increments
SWR
-65 to -5 dBm in 1 dB increments
Select:
Ant
7.07 to 7071.03 μV in 1 dB increments
T/R
0.22 to 707.11 μV in 1 dB increments
SWR
125.74 to 125743.3 μV in 1 dB increments
Ext Attn dB (Generator)
Used to select the external attenuation on the output connector.
Select:
0 to 30 dB in 1 dB increments
MHz (Receiver)
Used to select the signal receiver frequency.
Range:
2.000000 to 1000.000000 MHz in 0.000001 MHz
increments
Port (Receiver)
Used to select the signal receiver input connector.
Select:
Ant or T/R
Mod (Receiver)
Used to select the signal receiver modulation type.
Select:
AM
Modulation Meter changes to AM%.
FM
Modulation Meter changes to FM DEV.
IFBW
(field to right of Mod Field)
Used to select the IF bandwidth.
Select:
(for AM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k or 30k
(for FM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k, 30k, 100k
or 300k
AFBW (Receiver)
Used to select the bandwidth filter.
Select:
0.3k LP, 3k LP, 5k LP, 15k LP, CCITT BP, C-Wt BP,
0.3-3k BP, 0.3-5k BP, 0.3-20k BP, 0.3k HP or None.
More
Toggles the Receiver Frame to display the Cable Offset and Preamp
Fields.
Cable Offset (Receiver)
Used to select the cable loss. Cable loss is used by the RSSI and
Power Meters to display the power level at the UUT.
Select:
0 to 30.0 dB in 0.01 dB steps
Ext Attn dB (Receiver)
Used to select the external attenuation on the input connector.
Select:
0.0 to 30.0 dB in 0.1 dB increments
Preamp (Receiver)
Used to select preamp operation.
Select:
Auto, On or Off
Modulation Type
Used to select the modulation type.
Select:
AM, FM or Off
Subject to Export Control, see Cover Page for details.
2-11
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
Modulator
Used to change functionality of the modulation source fields.
Press F1 “ENTER” Key to toggle between Analog (CTCSS), DCS and
DTMF modulation source fields.
NOTE:
The total combined modulation from all sources in each
Modulatorframe cannot exceed 100% for AM or 100 kHz for
FM.
If the modulation level of a selection source is set to a value
that would cause the total modulation to exceed the
modulation limit, the value of the unselected sources are
lowered automatically.
Analog (CTCSS) Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Gen 2
Used to select internal modulation.
This setting can be toggled between Gen 2, DCS (Digitally Coded
Squelch) and DCS INV (Inverse DCS).
Select:
On or Off
Select:
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
MIC
Used to select the external Microphone and the level of modulation for
the microphone input.
Select:
On
The external Microphone modulates the test set
signal generator.
Off
Deactivates the external Microphone input.
AM
0% to 100% in 0.1% increments
FM
0 to 100 kHz in 0.01 kHz increments
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
Subject to Export Control, see Cover Page for details.
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
Ext Aud
Used to select external modulation.
Select:
On
Permits an external tone generator to modulate
the test set signal generator.
Off
Deactivates the external Audio input.
DCS Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Dcs
Used to select the DCS state.
Select:
AM:
Inv (Interted), NonInv (Non-Inverted) or Off
DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054,
065, 071, 072, 073, 074, 114, 115, 116, 125,
131, 132, 134, 143, 152, 155, 156, 162, 165,
172, 174, 205, 223, 226, 243, 244, 245, 251,
261, 263, 265, 271, 306, 311, 315, 331, 343,
346, 351, 364, 365, 371, 411, 412, 413, 423,
431, 432, 445, 464, 465, 466, 503, 506, 516,
532, 546, 565, 606, 612, 624, 627, 631, 632,
654, 662, 664, 703, 712, 723, 731, 732, 734,
743 or 754
%Mod
0% to 100% in 0.1% increments
Select:
FM:
Inv (Interted), NonInv (Non-Inverted) or Off
DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054,
065, 071, 072, 073, 074, 114, 115, 116, 125,
131, 132, 134, 143, 152, 155, 156, 162, 165,
172, 174, 205, 223, 226, 243, 244, 245, 251,
261, 263, 265, 271, 306, 311, 315, 331, 343,
346, 351, 364, 365, 371, 411, 412, 413, 423,
431, 432, 445, 464, 465, 466, 503, 506, 516,
532, 546, 565, 606, 612, 624, 627, 631, 632,
654, 662, 664, 703, 712, 723, 731, 732, 734,
743 or 754
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Subject to Export Control, see Cover Page for details.
2-13
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
MIC
Used to select the external Microphone and the level of modulation for
the microphone input.
Select:
On
The external Microphone modulates the test set
signal generator.
Off
Deactivates the external Microphone input.
AM
0% to 100% in 0.1% increments
FM
0 to 100 kHz in 0.01 kHz increments
Ext Aud
Used to select external modulation.
Select:
On
Permits an external tone generator to modulate
the test set signal generator.
Off
Deactivates the external Audio input.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
DTMF Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Dtmf
Used to select the DTMF state.
Select:
AM:
State
Burst, Cont (Continuous) or Off
%Mod
0% to 100% in 0.1% increments (Lo)
0% to 100% in 0.1% increments (Hi)
Seq
Up to 12 characters (0 to 9, A, B, C, D)
FM:
State
Burst, Cont (Continuous) or Off
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
0 to 100 kHz in 0.01 kHz increments
Seq
Up to 12 characters (0 to 9, A, B, C, D)
Mark
Used to select the DTMF timing.
Select:
100 to 1000 ms in 1 ms increments
Space
Used to select the DTMF timing.
Select:
100 to 1000 ms in 1 ms increments
Subject to Export Control, see Cover Page for details.
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
Volume
Used to select the Handset volume level.
Select:
0 to 100
Squelch
Used to select the Squelch level for Duplex and Transmitter tests.
Select:
-150 to 50 dBm in 1 dB increments
Squelch operates in conjunction with the Receiver RSSI Meter.
When the RSSI Meter is under this threshold, then the speaker
audio is silenced. The RSSI Meter does not need to be displayed
on the screen for squelch to be operational.
Speaker
Used to select the Speaker Output.
Select:
Audio In, Demod or Fgen
Aud Out
Used to select the Audio Output Connector.
Select:
Audio In, Demod or Fgen
Save
Displays the Save Configuration Screen (para 2-2-7B) to store the
current state of the test screen in the internal memory.
Recall
Displays the Recall Configuration Screen (para 2-2-7A) to recall a
stored state of the test screen from internal memory.
Meters (not shown)
Several Meters can be selected to appear on the Duplex Test
Screen.
Meters are selected in the Duplex Test Setup Screen.
F1 “Edit” / “Done” / “Zoom” /
“Enter”
Edit
Highlights the selected field to be changed or changes
the field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Zoom
Displays the screen of the field selected.
Enter
Moves cursor into meter / function on test screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the
screen. Meters save configurations and readings.
Control frames save settings. The data dump is stored
in a time-stamped ASCII report and can be retrieved at
a later time.
F3 “Hold” / “Resume” / “Find”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Find
Used to scan and find RF signals.
F4 “Setup”
Displays the Duplex Test Setup Screen.
Subject to Export Control, see Cover Page for details.
2-15
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
F5 “Ptt on” / “Ptt off” / “Esc”
Ptt on
Activates MIC. Turns RF Generator ON and turns
Demod Audio OFF.
Ptt off
Deactivates MIC. Turns RF Generator OFF and turns
Demod Audio ON.
Esc
Ends the Field Edit, but does NOT save any changes
to the setting or value.
Subject to Export Control, see Cover Page for details.
A.
Duplex Test Screen (cont)
When the Duplex Test Screen is displayed, press the F4 “Setup” Key to access the Duplex Test Setup
Screen:
DUPLEX TEST SETUP
Modulation Meter
0
DCS Decode
0
RSSI Meter
0
Audio Level
0
RF Error Meter
0
RF Power Meter
0
SINAD Meter
0
Distortion Meter
0
AF Counter
0
DTMF Decode
0
Edit
Return
1
4
7
2
5
8
3
6
9
41 20 29
Mod-FM Dev
16.670 kHz
RSSI
0.0 dBm
RF Error
0.0 kHz
RF Power
0.0 Watts
SINAD Audio In
0.0 dB
Distortion Audio In
0.0%
AF Cntr Audio In
0.0 Hz
DTMF Decode
01234
0123456789
DCS Decode
State Run
Inv 155
Audio Level Audio In
0.000 V
Subject to Export Control, see Cover Page for details.
2-17
A.
Duplex Test Screen (cont)
SCREEN FEATURE
FUNCTION
Modulation Meter
Used to select the position of the Modulation Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
RSSI Meter
Used to select the position of the RSSI Meter on the Duplex Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
RF Error Meter
Used to select the position of the RF Error Meter on the Duplex Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
RF Power Meter
Used to select the position of the RF Power Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
SINAD Meter
Used to select the position of the SINAD Meter on the Duplex Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
Distortion Meter
Used to select the position of the Distortion Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 6, 8 or 9
AF Counter
Used to select the position of the AF Counter on the Duplex Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
DTMF Decode
Used to select the position of the DTMF Decode Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
DCS Decode
Used to select the position of the DCS Decode Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
Audio Level
Used to select the position of the Audio Level Meter on the Duplex
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
Meter Chart
Displays the areas of the Duplex Test Screen and a number
representing each area (i.e., 3 is top right on the Duplex Test
Screen, etc.).
F1 “Edit” / “Done” / “Zoom
Edit
Highlights the selected field to be changed.
Done
Ends the Field Edit and saves the new setting / value.
Zoom
Displays the screen of the field selected.
F2 “Return”
Displays the Duplex Test Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting
or value.
Subject to Export Control, see Cover Page for details.
B.
Receiver Test Screen
When the System Menu is displayed, press the 2 Key to access the Receiver Test Screen:
Edit
Return
Hold
Setup
RECEIVER TEST
Generator
Off
MH z: 40.000000
Port: T/R
Level: -70 dBm
Ext Attn dB: 0
Modulator Freq FM Analog
Gen 1: On 1000.0 H z 6.25 kH z
Gen 2: On 150.0 H z 3.25 kH z
MIC: On 6.25 kH z
Ext Aud: Off Load: High Z
Volume:
100
Squelch:
-50 dBm
Speaker:
Audio In
AudOut:
Audio In
Save
Recall
41 20 29
(CTCSS)
Modulator Freq/Code FM DCS
Gen 1: Off 150.0 H z
3.50 kH z
Dcs: Non Inv 023
6.25 kH z
MIC: Off
0.00 kH z
Ext Aud: Off Load: High Z
Modulator FM DTMF
Gen 1: Off 150.0 H z 3.50 kH z
DTMF: Burst Trig Lo: 6.25 kH z
Seq: 0123456789 Hi: 6.25 kH z
Mark: 200 ms Space: 200 ms
(DCS) (DTMF)
SCREEN FEATURE
FUNCTION
Status (Generator)
Displays the status (On / Off) of the Generator.
MHz
Used to select the signal generator frequency.
Range:
2.000000 to 1000.000000 MHz in 0.000001 MHz
increments
Port
Used to select the signal generator output connector.
Select:
Ant, T/R or SWR
Subject to Export Control, see Cover Page for details.
2-19
B.
Receiver Test Screen (cont)
SCREEN FEATURE
FUNCTION
Level
Used to select the signal generator output level.
The Generator Output Level Units can be toggled between dBm and
μV.
Select:
Ant
-90 to -30 dBm in 1 dB increments
T/R
-120 to -50 dBm in 1 dB increments
SWR
-65 to -5 dBm in 1 dB increments
Select:
Ant
7.07 to 7071.03 μV in 1 dB increments
T/R
0.22 to 707.11 μV in 1 dB increments
SWR
125.74 to 125743.3 μV in 1 dB increments
Ext Attn dB
Used to select the external attenuation on the output connector.
Select:
0 to 30 dB in 1 dB increments
Modulation Type
Used to select the modulation type.
Select:
AM, FM or Off
Modulator
Used to change functionality of the modulation source fields.
Press F1 “ENTER” Key to toggle between Analog (CTCSS), DCS and
DTMF modulation source fields.
NOTE:
The total combined modulation from all sources in each
Modulatorframe cannot exceed 100% for AM or 100 kHz for
FM.
If the modulation level of a selection source is set to a value
that would cause the total modulation to exceed the
modulation limit, the value of the unselected sources are
lowered automatically.
Analog (CTCSS) Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Subject to Export Control, see Cover Page for details.
B.
Receiver Test Screen (cont)
SCREEN FEATURE
FUNCTION
Gen 2
Used to select internal modulation.
This setting can be toggled between Gen 2, DCS (Digitally Coded
Squelch) and DCS INV (Inverse DCS).
Select:
On or Off
Select:
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
MIC
Used to select the external Microphone and the level of modulation for
the microphone input.
Select:
On
The external Microphone modulates the test set
signal generator.
Off
Deactivates the external Microphone input.
AM
0% to 100% in 0.1% increments
FM
0 to 100 kHz in 0.01 kHz increments
Ext Aud
Used to select external modulation.
Select:
On
Permits an external tone generator to modulate
the test set signal generator.
Off
Deactivates the external Audio input.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
DCS Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Subject to Export Control, see Cover Page for details.
2-21
B.
Receiver Test Screen (cont)
SCREEN FEATURE
FUNCTION
Dcs
Used to select the DCS state.
Select:
AM:
Inv (Interted), NonInv (Non-Inverted) or Off
DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054,
065, 071, 072, 073, 074, 114, 115, 116, 125,
131, 132, 134, 143, 152, 155, 156, 162, 165,
172, 174, 205, 223, 226, 243, 244, 245, 251,
261, 263, 265, 271, 306, 311, 315, 331, 343,
346, 351, 364, 365, 371, 411, 412, 413, 423,
431, 432, 445, 464, 465, 466, 503, 506, 516,
532, 546, 565, 606, 612, 624, 627, 631, 632,
654, 662, 664, 703, 712, 723, 731, 732, 734,
743 or 754
%Mod
0% to 100% in 0.1% increments
Select:
FM:
Inv (Interted), NonInv (Non-Inverted) or Off
DCS Code 023, 025, 026, 031, 032, 043, 047, 051, 054,
065, 071, 072, 073, 074, 114, 115, 116, 125,
131, 132, 134, 143, 152, 155, 156, 162, 165,
172, 174, 205, 223, 226, 243, 244, 245, 251,
261, 263, 265, 271, 306, 311, 315, 331, 343,
346, 351, 364, 365, 371, 411, 412, 413, 423,
431, 432, 445, 464, 465, 466, 503, 506, 516,
532, 546, 565, 606, 612, 624, 627, 631, 632,
654, 662, 664, 703, 712, 723, 731, 732, 734,
743 or 754
Dev kHz
0 to 100 kHz in 0.01 kHz increments
MIC
Used to select the external Microphone and the level of modulation for
the microphone input.
Select:
On
The external Microphone modulates the test set
signal generator.
Off
Deactivates the external Microphone input.
AM
0% to 100% in 0.1% increments
FM
0 to 100 kHz in 0.01 kHz increments
Ext Aud
Used to select external modulation.
Select:
On
Permits an external tone generator to modulate
the test set signal generator.
Off
Deactivates the external Audio input.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
Subject to Export Control, see Cover Page for details.
B.
Receiver Test Screen (cont)
DTMF Modulation Source Fields
Gen 1
Used to select internal modulation.
Select:
On or Off
AM:
Freq
0 to 20000 Hz in 1 Hz increments
%Mod
0% to 100% in 0.1% increments
FM:
Freq
0 to 20000 Hz in 1 Hz increments
Dev kHz
0 to 100 kHz in 0.01 kHz increments
Dtmf
Used to select the DTMF state.
Select:
AM:
State
Burst, Cont (Continuous) or Off
%Mod
0% to 100% in 0.1% increments (Lo)
0% to 100% in 0.1% increments (Hi)
Seq
Up to 12 characters (0 to 9, A, B, C, D)
FM:
State
Burst, Cont (Continuous) or Off
Dev kHz
0 to 100 kHz in 0.01 kHz increments
0 to 100 kHz in 0.01 kHz increments
Seq
Up to 12 characters (0 to 9, A, B, C, D)
Mark
Used to select the DTMF timing.
Select:
100 to 1000 ms in 1 ms increments
Space
Used to select the DTMF timing.
Select:
100 to 1000 ms in 1 ms increments
Volume
Used to select the Handset volume level.
Select:
0 to 100
Squelch
Used to select the Squelch level for Duplex and Transmitter tests.
Select:
-150 to 50 dBm in 1 dB increments
Squelch operates in conjunction with the Receiver RSSI Meter. When
the RSSI Meter is under this threshold, then the speaker audio is
silenced. The RSSI Meter does not need to be displayed on the
screen for squelch to be operational.
Speaker
Used to select the Speaker Output.
Select:
Audio In or Mod
Aud Out
Used to select the Audio Output Connector.
Select:
Audio In or Mod
Save
Displays the Save Configuration Screen (para 2-2-7B) to store the
current state of the test screen in the internal memory.
Recall
Displays the Recall Configuration Screen (para 2-2-7A) to recall a
stored state of the test screen from internal memory.
Subject to Export Control, see Cover Page for details.
2-23
B.
Receiver Test Screen (cont)
SCREEN FEATURE
FUNCTION
Meters (not shown)
Several Meters can be selected to appear on the Receiver Test
Screen.
Meters are selected in the Receiver Test Setup Screen.
F1 “Edit” / “Done” / “Zoom” /
“Enter”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Zoom
Displays the screen of the field selected.
Enter
Moves cursor into meter / function on test screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen.
Meters save configurations and readings. Control frames
save settings. The data dump is stored in a time-stamped
ASCII report and can be retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F4 “Setup”
Displays the Receiver Test Setup Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting
or value.
Subject to Export Control, see Cover Page for details.
B.
Receiver Test Screen (cont)
RECEIVER TEST SETUP
SINAD Meter
0
Distortion Meter
0
AF Counter
0
Audio Level
0
7
Edit
Return
1
4
2
5
8
3
6
9
41 20 29
SINAD Audio In
0.0 dB
Distortion Audio In
0.0%
AF Cntr Audio In
0.0 Hz
Audio Level Audio In
0.000 V
SCREEN FEATURE
FUNCTION
SINAD Meter
Used to select the position of the SINAD Meter on the Receiver Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
Distortion Meter
Used to select the position of the Distortion Meter on the Receiver
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
AF Counter
Used to select the position of the AF Counter on the Receiver Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
Audio Level
Used to select the position of the Audio Level Meter on the Receiver
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 6, 8 or 9
Subject to Export Control, see Cover Page for details.
2-25
B.
Receiver Test Screen (cont)
SCREEN FEATURE
FUNCTION
Meter Chart
Displays the areas of the Receiver Test Screen and a number
representing each area (i.e., 3 is top right on the Receiver Test
Screen, etc.).
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Receiver Test Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting or
value.
Subject to Export Control, see Cover Page for details.
C.
Transmitter Test Screen
When the System Menu is displayed, press the 3 Key to access the Transmitter Test Screen:
Edit
Return
Hold
Setup
TRANSMITTER TEST
Receiver More
MH z: 40.000000
Port: T/R
Mod: FM 10k
AFBW: None
Volume:
100
Squelch:
-50 dBm
Speaker:
Audio In
AudOut:
Audio In
Save
Recal l
41 20 29
SCREEN FEATURE
FUNCTION
MHz
Used to select the signal receiver frequency.
Range:
2.000000 to 1000.000000 MHz in 0.000001 MHz
increments
Port
Used to select the signal receiver input connector.
Select:
Ant or T/R
Mod
Used to select the signal receiver modulation type.
Select:
AM
Modulation Meter changes to AM%.
FM
Modulation Meter changes to FM DEV.
IFBW
(field to right of Mod Field)
Used to select the IF bandwidth.
Select:
(for AM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k or 30k
(for FM): 5k, 6.25k, 8.33k, 10k, 12.5k, 25k, 30k, 100k
or 300k
AFBW
Used to select the bandwidth filter.
Select:
0.3k LP, 3k LP, 5k LP, 15k LP, CCITT BP, C-Wt BP,
0.3-3k BP, 0.3-5k BP, 0.3-20k BP, 0.3k HP or None.
More
Toggles the Receiver Frame to display the Ext Attn dB and Preamp
Fields.
Ext Attn dB
Used to select the external attenuation on the input connector.
Select:
0.0 to 30.0 dB in 0.1 dB increments
TRANSMITTER TEST
Receiver More
Ext Attn dB: 0.0
Preamp: Auto
Subject to Export Control, see Cover Page for details.
2-27
C.
Transmitter Test Screen (cont)
SCREEN FEATURE
FUNCTION
Preamp (Receiver)
Used to select preamp operation.
Select:
Auto, On or Off
Volume
Used to select the Handset volume level.
Select:
0 to 100
Squelch
Used to select the Squelch level for Duplex and Transmitter tests.
Select:
-150 to 50 dBm in 1 dB increments
Squelch operates in conjunction with the Receiver RSSI Meter.
When the RSSI Meter is under this threshold, then the speaker
audio is silenced. The RSSI Meter does not need to be displayed
on the screen for squelch to be operational.
Speaker
Used to select the Speaker Output.
Select:
Audio In, Demod or Fgen
Aud Out
Used to select the Audio Output Connector.
Select:
Audio In, Demod or Fgen
Save
Displays the Save Configuration Screen (para 2-2-7B) to store the
current state of the test screen in the internal memory.
Recall
Displays the Recall Configuration Screen (para 2-2-7A) to recall a
stored state of the test screen from internal memory.
Meters (not shown)
Several Meters can be selected to appear on the Transmitter Test
Screen.
Meters are selected in the Transmitter Test Setup Screen.
F1 “Edit” / “Done” / “Zoom” /
“Enter”
Edit
Highlights the selected field to be changed or changes
the field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Zoom
Displays the screen of the field selected.
Enter
Displays additional fields on test screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the
screen. Meters save configurations and readings.
Control frames save settings. The data dump is stored
in a time-stamped ASCII report and can be retrieved at a
later time.
F3 “Hold” / “Resume” / “Find”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Find
Used to scan and find RF signals.
F4 “Setup”
Displays the Transmitter Test Setup Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting
or value.
Subject to Export Control, see Cover Page for details.
C.
Transmitter Test Screen (cont)
When the Transmitter Test Screen is displayed, press the F4 “Setup” Key to access the Transmitter
Test Setup Screen:
TX TEST SETUP
Fgen
0
DTMF Decode
0
Modulation Meter
0
DCS Decode
0
RSSI Meter
0
Audio Level
0
RF Error Meter
0
Distortion Meter
0
SINAD Meter
0
RF Power Meter
0
AF Counter
0
Edit
Return
1
4
7
2
5
8
3
6
9
41 20 29
Function Generator
Freq Level
#1: Off 0.0 Hz 0.20 Vrms
#2: Off 0.0 Hz 0.20 Vrms
Mod-FM Dev
16.670 kHz
RSSI
0.0 dBm
RF Error
0.0 kHz
Distortion Audio In
0.0%
SINAD Audio In
0.0 dB
RF Power
0.0 Watts
AF Cntr Audio In
0.0 Hz
DTMF Decode
01234
0123456789
DCS Decode
State Run
Inv 155
Audio Level Audio In
0.000 V
Subject to Export Control, see Cover Page for details.
2-29
C.
Transmitter Test Screen (cont)
SCREEN FEATURE
FUNCTION
Fgen (Function Generator)
Used to select the position of the Function Generator on the
Transmitter Test Screen (refer to Meter Chart).
Since the Function Generator occupies the screen space of two
functions on the Transmitter Test Screen, the space directly adjacent
to the screen space selected must be empty in order for the Function
Generator to be displayed. (e.g. To select screen space 2; screen
space 3 must be empty)
Select:
0 (Meter not shown), 2, 4, 5 or 8
Status
Select:
On or Off
Freq
Select:
0 to 20000 Hz in 0.1 Hz increments
Level
Select:
0.00 to 1.57 Vrms in 0.01 V increments
The Function Generator utilizes the AUDIO Connector for signal
output.
Modulation Meter
Used to select the position of the Modulation Meter on the Transmitter
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
RSSI Meter
Used to select the position of the RSSI Meter on the Transmitter Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
RF Error Meter
Used to select the position of the RF Error Meter on the Transmitter
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
Distortion Meter
Used to select the position of the Distortion Meter on the Transmitter
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
SINAD Meter
Used to select the position of the SINAD Meter on the Transmitter
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
RF Power Meter
Used to select the position of the RF Power Meter on the Transmitter
Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
AF Counter
Used to select the position of the AF Counter on the Transmitter Test
Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
DTMF Decode
Used to select the position of the DTMF Decode Meter on the
Transmitter Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
DCS Decode
Used to select the position of the DCS Decode Meter on the
Transmitter Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
Subject to Export Control, see Cover Page for details.
C.
Transmitter Test Screen (cont)
SCREEN FEATURE
FUNCTION
Audio Level
Used to select the position of the Audio Level Meter on the
Transmitter Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 2, 3, 4, 5, 6, 8 or 9
Meter Chart
Displays the areas of the Transmitter Test Screen and a number
representing each area (i.e., 3 is top right on the Transmitter Test
Screen, etc.).
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Transmitter Test Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting or
value.
Subject to Export Control, see Cover Page for details.
2-31
D.
ANT-Cable Test Screen
When the System Menu is displayed, press the 4 Key to access the ANT-Cable Test Screen:
ANT-CABLE TEST
7.00
2009-01-06
11:35:30
SWR
1.00
35.0 MHz 45.0
Type: SWR Freq (MHz): 40.0 Span (MHz): 10.0
Start (MHz): 35.0 Stop (MHz): 45.0
Edit
Return
Hold
Cal
Marker
41 20 29
(RF Mode)
SCREEN FEATURE
FUNCTION
VSWR Progress Bar
A graphical representation of the percentage completed for the
current measurement.
Type
Used to select the mode of testing.
Select:
SWR, DTF, RL, LOSS or Raw
Freq
Used to select/display the Center Frequency.
Range:
2.0 to 1000.0 MHz in 0.1 MHz increments
Displays the Center Frequency entered by the operator or the
calculated Center Frequency if the Start and Stop Frequencies are
entered.
Span
Used to select/display the Frequency Span.
Range:
(SWR)
10 to 998 MHz in 0.1 MHz increments
(DTF)
100 to 998 MHz in 0.1 MHz increments
(RL)
10 to 998 MHz in 0.1 MHz increments
(LOSS) 10 to 998 MHz in 0.1 MHz increments
Displays the Frequency Span entered by the operator or the
calculated Frequency Span if the Start and Stop Frequencies are
entered.
Subject to Export Control, see Cover Page for details.
D.
ANT-Cable Test Screen (cont)
SCREEN FEATURE
FUNCTION
Start
Used to select/display the Start Frequency.
Range:
2.0 to 1000 MHz in 0.1 MHz increments
Displays the Start Frequency entered by the operator or the
calculated Start Frequency if the Center Frequency and Frequency
Span are entered.
Stop
Used to select/display the Stop Frequency.
Range:
2.0 to 1000 MHz in 0.1 MHz increments
Displays the Stop Frequency entered by the operator or the calculated
Stop Frequency if the Center Frequency and Frequency Span are
entered.
F1 “Edit” / “Done” / “Next”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Next
Displays the next pop-up screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume” /
“Abort”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Abort
Stops the action to calibrate the SWR Connector.
F4 “Cal”
Instruction pop-ups are displayed to calibrate the SWR Connector.
F5 “Marker” / “Scale”
“RF” / “Esc”
Marker
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Marker Mode.
Scale
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Scale Mode.
RF
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to RF Mode.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
2-33
D.
ANT-Cable Test Screen (cont)
ANT-CABLE TEST
7.00
2009-06-25
11:35:30
SWR
1.00
35.0 MHz 45.0
Marker: 1 Off Delta: 1 Pos: 0.00 Delta 0.00
Move Left Right VSWR 0.00 Delta 0.00
Edit
Return
Hold
Cal
Scale
41 20 29
(Marker Mode)
ANT-CABLE TEST
0.00
2009-06-25
11:35:30
dB
-50.0
0.1 Ft 415.5
Marker: 1 Off Delta: 1 Pos: 0.00 Delta 0.00
Move Left Right dB 0.00 Delta 0.00
Edit
Return
Hold
Cal
Cable
41 20 29
(DTF - Marker Mode)
Subject to Export Control, see Cover Page for details.
D.
ANT-Cable Test Screen (cont)
SCREEN FEATURE
FUNCTION
VSWR Progress Bar
A graphical representation of the percentage completed for the
current measurement.
Marker
Used to select and enable one of three markers on the Graphical
Display.
Select:
1 to 3
Marker Status
Used to set the Marker selected to ON or OFF.
Delta
Used to enable the Delta Marker Function.
Select:
1 to 3
DTF
Displays the distance to fault.
Delta (Top)
Displays the Delta in SWR/Return Loss between the Active Marker
selected in the Marker Field and the Marker selected in the Delta
Field.
Move/Min/Max
Used to move the Active Marker on the Graphical Display.
Select:
Max, Min or Move
Left Right
Used to move the Active Marker selected in the Marker Field to the
left or to the right on the Graphical Display.
Pos
Displays the Horizontal Axis of the Active Marker.
VSWR / dB
Displays the reading of the Active Marker.
VSWR
Displays the SWR reading.
dB
Displays the DTF, RL or LOSS reading.
Delta (Bottom)
Displays the Delta in Frequency or Distance between the Active
Marker selected in the Marker Field and the Marker selected in the
Delta Field.
F1 “Edit” / “Done” / “Next”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Next
Displays the next pop-up screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume” /
“Abort”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Abort
Stops the action to calibrate the SWR Connector.
F4 “Cal”
Instruction pop-ups are displayed to calibrate the SWR Connector.
Subject to Export Control, see Cover Page for details.
2-35
D.
ANT-Cable Test Screen (cont)
SCREEN FEATURE
FUNCTION
F5 “Marker” / “Scale”
“Cable” / “RF” / “Esc”
Marker
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Marker Mode.
Scale
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Scale Mode.
Cable
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Cable Mode.
RF
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to RF Mode.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
D.
ANT-Cable Test Screen (cont)
ANT-CABLE TEST
0.00
2009-06-25
11:35:30
dB
-50.0
0.1 Ft 415.5
Cable: USER Velocity: 0.66 Loss: 3.00
Est Length: 415.5 Unit Feet
Edit
Return
Hold
Cal
Scale
41 20 29
(DTF - Cable Mode)
SCREEN FEATURE
FUNCTION
VSWR Progress Bar
A graphical representation of the percentage completed for the
current measurement.
Cable
Used to select the type of coaxial cable used on the system under
test.
Select:
RG-400, RG-223, RG-214, RG-213, RG-174, RG-58C,
RG-58B, RG-58A, RG-58foam, RG-58, RG-55B, RG-55A,
RG-55, RG-8A, RG-8foam, RG-8, RG-8x or USER.
Velocity
Used to select the velocity of the propergation (Vp) factor for the
cable selected.
Select:
0.0 to 1.0 in 0.01 increments
Loss
Used to select the cable insertion loss per 100 ft for the cable
selected.
Select:
0.00 to 100.00 in 0.01 increments
Est Length
Used to select the estimated length of the cable under test.
Select:
42.0 to 619.4 ft in 0.1 ft increments.
12.8 to 304.8 m in 0.1 m increments
When an estimated length is entered, the frequency span adjusts to
the correct level automatically.
Unit
Used to select the units of measure.
Select:
Feet or Meters
Subject to Export Control, see Cover Page for details.
2-37
D.
ANT-Cable Test Screen (cont)
SCREEN FEATURE
FUNCTION
F1 “Edit” / “Done” / “Next”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Next
Displays the next pop-up screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume” /
“Abort”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Abort
Stops the action to calibrate the SWR Connector.
F4 “Cal”
Instruction pop-ups are displayed to calibrate the SWR Connector.
F5 “Marker” / “Scale”
“RF” / “Esc”
Marker
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Marker Mode.
Scale
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Scale Mode.
RF
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to RF Mode.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
D.
ANT-Cable Test Screen (cont)
ANT-CABLE TEST
7.0
0.00
2009-01-06
11:35:30
dB
-50.0
0.1 Ft 415.5
Scale: User Top: 0 Bottom: -50
Edit
Return
Hold
Cal
RF
41 20 29
(Scale Mode)
SCREEN FEATURE
FUNCTION
VSWR Progress Bar
A graphical representation of the percentage completed for the
current measurement.
Scale
Used to scale the Vertical Axis of the Graphical Display.
Select:
Fixed or User
Top
Used to set the upper limit of the Vertical Axis.
Select:
-100 to 100
Bottom
Used to set the lower limit of the Vertical Axis.
Select:
-100 to 100
F1 “Edit” / “Done” / “Next”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Next
Displays the next pop-up screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume” /
“Abort”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
Abort
Stops the action to calibrate the SWR Connector.
F4 “Cal”
Instruction pop-ups are displayed to calibrate the SWR Connector.
Subject to Export Control, see Cover Page for details.
2-39
D.
ANT-Cable Test Screen (cont)
SCREEN FEATURE
FUNCTION
F5 “Marker” / “Scale”
“RF” / “Esc”
Marker
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Marker Mode.
Scale
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to Scale Mode.
RF
Used to change the displayed fields and functionality
on the ANT-Cable Test Screen to RF Mode.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
E.
Audio Function Generator Test Screen
When the System Menu is displayed, press the 5 Key to access the Audio Function Generator Test
Screen.
The Audio Function Generator Test Screen utilizes the AUDIO Connector for signal output.
Edit
Return
Hold
Setup
AF GEN
Function Generator
Freq Level
# 1: On 1000.0 Hz 1.00 Vrms
# 2: On 2400.0 Hz 1.00 Vrms
Volume:
100
Squelch:
-50 dBm
Speaker:
Audio In
AudOut:
Audio In
Save
Recal l
41 20 29
SCREEN FEATURE
FUNCTION
#1 (Function Generator)
Used to select Function Generator #1.
Select:
On or Off
Freq
0 to 20000 Hz in 0.1 Hz increments
Level
0.00 to 1.57 Vrms in 0.01 V increments
#2 (Function Generator)
Used to select Function Generator #2.
Select:
On or Off
Freq
0 to 20000 Hz in 0.1 Hz increments
Level
0.00 to 1.57 Vrms in 0.01 V increments
NOTE:
The combined output level from both Function Generators cannot exceed 1.57 Vrms.
If the level of a selected Function Generator is set so the combined output level would
exceed 1.57 Vrms, then the output level of the unselected Function Generator is lowered
automatically.
Volume
Used to select the Handset volume level.
Select:
0 to 100
Subject to Export Control, see Cover Page for details.
2-41
E.
Audio Function Generator Test Screen (cont)
SCREEN FEATURE
FUNCTION
Squelch
Used to select the Squelch level for Duplex and Transmitter tests.
Select:
-150 to 50 dBm in 1 dB increments
Squelch operates in conjunction with the Receiver RSSI Meter.
When the RSSI Meter is under this threshold, then the speaker audio
is silenced. The RSSI Meter does not need to be displayed on the
screen for squelch to be operational.
Speaker
Used to select the Speaker Output.
Select:
Audio In, Demod or Fgen
Aud Out
Used to select the Audio Output Connector.
Select:
Audio In, Demod or Fgen
Save
Displays the Save Configuration Screen (para 2-2-7B) to store the
current state of the test screen in the internal memory.
Recall
Displays the Recall Configuration Screen (para 2-2-7A) to recall a
stored state of the test screen from internal memory.
Meters (not shown)
Several Meters can be selected to appear on the Audio Function
Generator Screen.
Meters are selected in the Audio Function Generator Setup Screen.
F1 “Edit” / “Done” / “Zoom” /
“Enter”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
Zoom
Displays the screen of the field selected.
Enter
Moves cursor into meter / function on test screen.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen.
Meters save configurations and readings. Control frames
save settings. The data dump is stored in a time-stamped
ASCII report and can be retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F4 “Setup”
Displays the Audio Function Generator Setup Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting
or value.
Subject to Export Control, see Cover Page for details.
E.
Audio Function Generator Test Screen (cont)
When the Audio Function Generator Test Screen is displayed, press the F4 “Setup” Key to access the
Audio Function Generator Test Setup Screen:
AF GEN SETUP
SINAD Meter
0
Distortion Meter
0
AF Counter
0
Audio Level
0
7
Edit
Return
1
4
2
5
8
3
6
9
41 20 29
SINAD Audio In
0.0 dB
Distortion Audio In
0.0%
AF Cntr Audio In
0.0 Hz
Audio Level Audio In
0.000 V
SCREEN FEATURE
FUNCTION
SINAD Meter
Used to select the position of the SINAD Meter on the Audio Function
Generator Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 4, 5, 6, 8 or 9
Distortion Meter
Used to select the position of the Distortion Meter on the Audio
Function Generator Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 4, 5, 6, 8 or 9
AF Counter
Used to select the position of the AF Counter on the Audio Function
Generator Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 4, 5, 6, 8 or 9
Subject to Export Control, see Cover Page for details.
2-43
E.
Audio Function Generator Test Screen (cont)
SCREEN FEATURE
FUNCTION
Audio Level
Used to select the position of the Audio Level Meter on the Audio
Function Generator Test Screen (refer to Meter Chart).
Select:
0 (Meter not shown), 3, 4, 5, 6, 8 or 9
Meter Chart
Displays the areas of the Audio Function Generator Test Screen and a
number representing each area (i.e., 3 is top right on the Audio
Function Generator Test Screen, etc.).
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Audio Function Generator Test Screen.
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting or
value.
Subject to Export Control, see Cover Page for details.
2-2-3.
METERS MENU
When the System Menu, Self Test Menu or Utilities Menu is displayed, press the F2 “Meters” Key to
access the Meters Menu:
Meters
System
Selftest
Util
1 - SINAD
2 - DISTORTION
3 - AF COUNTER
4 - AUDIO LEVEL METER
SCREEN FEATURE
FUNCTION
1 - SINAD
Displays the SINAD Meter Screen (para 2-2-3A).
2 - DISTORTION
Displays the Distortion Meter Screen (para 2-2-3B).
3 - AF COUNTER
Displays the AF Counter Screen (para 2-2-3C).
4 - AUDIO LEVEL METER
Displays the Audio Level Meter Screen (para 2-2-3D).
F2 “Meters”
Displays the Meters Menu (para 2-2-3).
F3 “System”
Displays the System Menu (para 2-2-2).
F4 “Selftest”
Displays the Self Test Menu (para 2-2-4).
F5 “Util”
Displays the Utilities Menu (para 2-2-5).
Subject to Export Control, see Cover Page for details.
2-45
A.
SINAD Meter Screen
When the Meters Menu is displayed, press the 1 Key to access the SINAD Meter Screen:
The SINAD Meter Screen utilizes the AUDIO Connector and AUDIO IN Connector for signal input.
SINAD Audio In
0.0 dB
Edit
Return
Hold
SINAD
Source
Audio In
Load
High Z
Avg Reading
1
Range
Auto
Filter
15k LP
Limits dB State
Lower
0.0 Off
Upper
60.0 Off
59.1
0.0
dB
60.0
41 20 29
(MINI-METER)
SCREEN FEATURE
FUNCTION
Source
Used to select the SINAD Meter input source on the SINAD Meter
Screen and/or the SINAD Mini-Meter.
Select:
Audio In or Demod (Duplex Test Screen)
Audio In (Receiver Test Screen)
Audio In or Demod (Transmitter Test Screen)
Audio In (Audio Function Generator Screen)
When the SINAD Meter Screen is selected from the Meters Menu,
‘Audio In’ is the only setting available.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
Avg Reading
Used to select the SINAD Meter Averaging.
Select:
1 to 99
This is the number of readings to average for the displayed value.
Range
Used to select the meter range.
Select:
Auto, 0-20dB, 0-40dB or 0-60dB
Filter
Used to select the audio filter.
Select:
None. 15k LP or 0.3-3k BP
Subject to Export Control, see Cover Page for details.
A.
SINAD Meter Screen (cont)
SCREEN FEATURE
FUNCTION
Limits - Lower
Used to enable the SINAD Meter Low Limit.
Select:
0.0 to 60.0 dBm in 0.1 dB increments
Sets the marker on the SINAD Meter Bar to the Lower Limit selected.
Limits - Upper
Used to enable the SINAD Meter Upper Limit.
Select:
0.0 to 60.0 dBm in 0.1 dB increments
Sets the marker on the SINAD Meter Bar to the Upper Limit selected.
State - Lower Limit
Used to display the Lower Limit Marker on the SINAD Meter Bar.
Select:
On or Off
State - Upper Limit
Used to display the Upper Limit Marker on the SINAD Meter Bar.
Select:
On or Off
SINAD Meter Bar
A graphical representation of the received SINAD Meter readings.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F5 “Return” / “Esc”
Return
Closes the SINAD Meter Screen and returns to the Test
Screen.
Esc
Ends the Field Edit, but does NOT save any changes to the
setting or value.
Subject to Export Control, see Cover Page for details.
2-47
B.
Distortion Meter Screen
When the Meters Menu is displayed, press the 2 Key to access the Distortion Meter Screen:
The Distortion Meter Screen utilizes the AUDIO Connector and AUDIO IN Connector (3500A only) for
signal input.
Distortion Audio In
0.0%
Edit
Return
Hold
DISTORTION
Source:
Audio In
Load:
150
Avg Reading:
1
Range:
Auto
Filter:
15k LP
Limits % State
Lower
0.0 Off
Upper
100.0 Off
99.0
0.0
%
100.0
41 20 29
(MINI-METER)
SCREEN FEATURE
FUNCTION
Source
Used to select the Distortion Meter input source on the Distortion
Meter Screen and/or the Distortion Mini-Meter.
Select:
Audio In or Demod (Duplex Test Screen)
Audio In (Receiver Test Screen)
Audio In or Demod (Transmitter Test Screen)
Audio In (Audio Function Generator Screen)
When the Distortion Meter Screen is selected from the Meters Menu,
‘Audio In’ is the only setting available.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
Avg Reading
Used to select the Distortion Meter Averaging.
Select:
1 to 99
This is the number of readings to average for the displayed value.
Range
Used to select the meter range.
Select:
Auto, 0-10%, 0-20%, 0-50% or 0-100%
Filter
Used to select the audio filter.
Select:
None. 15k LP or 0.3-3k BP
Subject to Export Control, see Cover Page for details.
B.
Distortion Meter Screen (cont)
SCREEN FEATURE
FUNCTION
Limits - Lower
Used to enable the Distortion Meter Low Limit.
Select:
0.0% to 100.0% in 0.1% increments
Sets the marker on the Distortion Bar to the Lower Limit selected.
Limits - Upper
Used to enable the Distortion Meter Upper Limit.
Select:
0.0% to 100.0% in 0.1% increments
Sets the marker on the Distortion Meter Bar to the Upper Limit
selected.
State - Lower Limit
Used to display the Lower Limit Marker on the Distortion Meter Bar.
Select:
On or Off
State - Upper Limit
Used to display the Upper Limit Marker on the Distortion Meter Bar.
Select:
On or Off
Distortion Meter Bar
A graphical representation of the received Distortion Meter readings.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F5 “Return” / “Esc”
Return
Closes the Distortion Meter Screen and returns to the Test
Screen.
Esc
Ends the Field Edit, but does NOT save any changes to the
setting or value.
Subject to Export Control, see Cover Page for details.
2-49
C.
AF Counter Screen
When the Meters Menu is displayed, press the 3 Key to access the AF Counter Screen:
The AF Counter Screen utilizes the AUDIO Connector and AUDIO IN Connector (3500A only) for
signal input.
AF Cntr Audio In
0.0 Hz
Edit
Return
Hold
AF COUNTER
Source
Audio In
Load
High Z
Avg Reading
1
Range
Auto
Limits
Hz State
Lower
15.0 Off
Upper
20000.0 Off
4926.0
15.0
Hz
20000.0
41 20 29
(MINI-METER)
SCREEN FEATURE
FUNCTION
Source
Used to select the AF Counter input source on the AF Counter Screen
and/or the AF Counter Mini-Meter.
Select:
Audio In, Demod, or Mod (Duplex Test Screen)
Audio In or Mod (Receiver Test Screen)
Audio In, Demod or Fgen (Transmitter Test Screen)
Audio In or Fgen (Audio Function Generator Test Screen)
When the AF Counter Screen is selected from the Meters Menu,
‘Audio In’ is the only setting available.
Load
Used to select the Audio input signal load (Ω).
Select:
150, 600, 1K (3500A), Div10 (3500A) or High Z
Avg Reading
Used to select the AF Counter Averaging.
Select:
1 to 99
This is the number of readings to average for the displayed value.
Range
Used to select the meter range.
Select:
Auto, 15-100Hz, 15-1000Hz, 15-10000Hz or 15-20000Hz
Limits - Lower
Used to select the AF Counter Lower Limit.
Select:
15.0 to 20000.0 Hz in 0.1 Hz increments
Sets the marker on the AF Counter Bar to the Lower Limit selected.
Subject to Export Control, see Cover Page for details.
C.
AF Counter Screen (cont)
SCREEN FEATURE
FUNCTION
Limits - Upper
Used to select the AF Counter Upper Limit.
Select:
15.0 to 20000.0 Hz in 0.1 Hz increments
Sets the marker on the AF Counter Bar to the Upper Limit selected.
State - Lower Limit
Used to display the Lower Limit Marker on the AF Counter Bar.
Select:
On or Off
State - Upper Limit
Used to display the Upper Limit Marker on the AF Counter Bar.
Select:
On or Off
AF Counter Bar
A graphical representation of the received AF Counter readings.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F5 “Return” / “Esc”
Return
Closes the AF Counter Screen and returns to the Test
Screen.
Esc
Ends the Field Edit, but does NOT save any changes to the
setting or value.
Subject to Export Control, see Cover Page for details.
2-51
D.
Audio Level Meter Screen
When the Meters Menu is displayed, press the 4 Key to access the Audio Level Meter Screen.
The Audio Level Meter Screen utilizes the AUDIO Connector, AUDIO IN Connector (3500A only) and
DVM Connector (3500A only) for signal input.
Audio Level Audio In
0.000 V
Edit
Return
Hold
AUDIO LEVEL METER
Source
DVM
Detector
RMS
DivBy20 Off
Load
High Z
Ext Load 1
Range
Auto
Unit
V
Avg Reading
1
Limits
Vol ts State
Lower
0.0 Off
Upper
50.0 Off
11.400
0.0
V
50.0
41 20 29
(MINI-METER)
SCREEN FEATURE
FUNCTION
Source
Used to select the Audio Level Meter input source on the Audio Level
Meter Screen and/or the Audio Level Meter Mini-Meter.
Select:
Audio In or DVM
Detector
Used to select the measurement type.
Select:
Peak+, Peak-, PK2PK or RMS
DivBy20
Used to select the divide-by-20 function on the output level (DVM
only)
Select:
On or Off
Load
Used to select the Audio input signal load (Ω).
Select:
Audio In
150, 600, 1K (3500A), Div10 (3500A) or High Z
DVM
High Z
Ext Load
Used to select the impedance of an external load. The selected
impedance value is used to calculate power when the Unit Field is set
to dBm or Watts.
Select:
1 to 90000 Ω in 1 Ω increments
Range
Used to select the meter range.
Select:
Auto, 0-0.1V, 0-0.2V, 0-0.5V, 0-1V or 0-3.5V
Subject to Export Control, see Cover Page for details.
D.
Audio Level Meter Screen (cont)
SCREEN FEATURE
FUNCTION
Unit
Used to select the Audio Level Meter units of measure.
Select:
dBm, dBuV, mV, V or Watts
Avg Reading
Used to select the Audio Level Meter Averaging.
Select:
1 to 99
This is the number of readings to average for the displayed value.
Limits - Lower
Used to select the Audio Level Meter Lower Limit.
Select:
0.0 to 100.0 V in 0.1 V increments
Sets the marker on the Audio Level Meter Bar to the Lower Limit
selected.
Limits - Upper
Used to select the Audio Level Meter Upper Limit.
Select:
0.0 to 100.0 V in 0.1 V increments
Sets the marker on the Audio Level Meter Bar to the Upper Limit
selected.
State - Lower Limit
Used to display the Lower Limit Marker on the Audio Level Meter Bar.
Select:
On or Off
State - Upper Limit
Used to display the Upper Limit Marker on the Audio Level Meter Bar.
Select:
On or Off
AF Counter Bar
A graphical representation of the received Audio Level Meter
readings.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return” / “Save”
Return
Displays the System Menu (para 2-2-2)
Save
Performs a data dump of frames displayed on the screen,
including configurations, readings and settings. The data
dump is stored in a time-stamped ASCII report and can be
retrieved at a later time.
F3 “Hold” / “Resume”
Hold
Freezes the screen.
Resume
Restores the screen to active mode.
F5 “Return” / “Esc”
Return
Closes the Audio Level Meter Screen and returns to the
Test Screen.
Esc
Ends the Field Edit, but does NOT save any changes to the
setting or value.
Subject to Export Control, see Cover Page for details.
2-53
2-2-4.
SELF TEST MENU
When the System Menu, Self Test Menu or Utilities Menu is displayed, press the F4 “Selftest” Key to
access the Self Test Menu:
Meters
System
Selftest
Util
1 - SELFTEST
2 - DIAGNOSTIC
3 - CALIBRATION
SCREEN FEATURE
FUNCTION
1 - SELFTEST
Displays the Self Test Screen (para 2-2-4A).
2 - DIAGNOSTIC
Displays the Diagnostic Screen (para 2-2-4B).
3 - CALIBRATION
Displays the Calibration Screen (para 2-2-4C).
F2 “Meters”
Displays the Meters Menu (para 2-2-3).
F3 “System”
Displays the System Menu (para 2-2-2).
F4 “Selftest”
Displays the Self Test Menu (para 2-2-4).
F5 “Util”
Displays the Utilities Menu (para 2-2-5).
Subject to Export Control, see Cover Page for details.
A.
Self Test Screen
When the Self Test Menu is displayed, press the 1 Key to access the Self Test Screen:
Edit
Return
Start
SELF TEST
Test Mode:
Normal Run
TDM
Pass
0
Fail
0
Modulation
Pass
0
Fail
0
41 20 29
SCREEN FEATURE
FUNCTION
Test Mode
Used to select the run mode of the Self Test.
Select:
Normal Run (runs Self Test one time)
Loop All (runs Self Test continuously)
TDM
Displays the pass/fail status of the TDM (Time-Division Multiplexing)
Self Test.
Each time the test is performed, the fields next to Pass or Fail are
incremented. The fields are cleared if the Self Test is re-initialized.
Modulation
Displays the pass/fail status of the Modulation Self Test.
Each time the test is performed, the fields next to Pass or Fail are
incremented. The fields are cleared if the Self Test is restarted.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Self Test Menu (para 2-2-4).
F5 “Start” / “Stop” / “Esc”
Start
Initiates the Self Test.
Stop
Terminates the Self Test.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
2-55
B.
Diagnostic Screen
When the Self Test Menu is displayed, press the 2 Key to access the Diagnostic Screen:
Edit
Return
Start
STAND ALONE TEST
Mode:
Normal Run
RF CPLD
Invalid
Distortion
Invalid
TDM
Invalid
Gen Lock
Invalid
FPGA
Invalid
Rec Lock
Invalid
Temperature
Invalid
Button Battery
Invalid
AM Mod
Invalid
AF Counter
Invalid
FM Mod
Invalid
Time Domain
Invalid
RF Power
Invalid
Freq Domain
Invalid
RF Error
Invalid
SWR
Invalid
RSSI
Invalid
DTMF
Invalid
SPI
Invalid
DCS
Invalid
SINAD
Invalid
RF CPLD
Pass:
0
Fail:
0
41 20 29
SCREEN FEATURE
FUNCTION
Mode
Used to select the run mode of the Diagnostic Tests.
Select:
Normal Run, Loop Selected, Run Selected or Loop All
RF CPLD
Used to test Complex Programmable Logic Device.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
TDM
Used to test the Time-Division Multiplexing.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
FPGA
Used to test the Field Programmable Gate Array.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Temperature
Used to test the Temperature. Sensing Devices.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
AM Mod
Used to test AM Modulation.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
FM Mod
Used to test FM Modulation.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Subject to Export Control, see Cover Page for details.
B.
Diagnostic Screen (cont)
SCREEN FEATURE
FUNCTION
RF Power
Used to test RF Power.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
RF Error
Used to test RF Error.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
RSSI
Used to test the Received Signal Strength Indication.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
SPI
Used to test Serial Peripheral Interface.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
SINAD
Used to test the SINAD Meter.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Distortion
Used to test the Distortion Meter.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Gen Lock
Used to test the Generator (1st LO / 2nd LO).
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Rec Lock
Used to test the Receiver (1st LO / 2nd LO).
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Button Battery
Used to test the battery used to maintain non-volatile memory.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
AF Counter
Used to test the AF Counter.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Time Domain
Used to test the Time Domain.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Freq Domain
Used to test the Frequency Domain.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
SWR
Used to test the SWR.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Subject to Export Control, see Cover Page for details.
2-57
B.
Diagnostic Screen (cont)
SCREEN FEATURE
FUNCTION
DTMF
Used to test the DTMF.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
DCS
Used to test the DCS.
The test status field (right of the test) displays INVALID until the test
is run, then displays RUNNING, STOPPED, PASSED or FAILED.
Pass / Fail Counters
Displays Pass / Fail record of the Diagnostic Test selected.
The Pass / Fail Counters are incremented each time the test is
performed. The Pass / Fail Counters are cleared if the Diagnostics
Screen is re-initialized.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Self Test Menu (para 2-2-4).
F5 “Start” / “Stop” / “Esc”
Start
Initiates the Diagnostic Testing.
Stop
Terminates the Diagnostic Testing.
Esc
Ends the Field Edit, but does NOT save any changes to
the setting or value.
Subject to Export Control, see Cover Page for details.
C.
Calibration Screen
When the Self Test Menu is displayed, press the 3 Key to access the Calibration Screen:
Edit
Return
CALIBRATION
CAL PASSWORD: 0
41 20 29
SCREEN FEATURE
FUNCTION
CAL PASSWORD
Used to enter the Calibration Password.
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Self Test Menu (para 2-2-4).
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting or
value.
Refer to the 3500 / 3500A Maintenance Manual for more information on calibrating the 3500 / 3500A.
Subject to Export Control, see Cover Page for details.
2-59
2-2-5.
UTILITIES SCREEN
When the System Menu, Meters Menu or Self Test Menu is displayed, press the F5 “Util” Key to
access the Utilities Menu:
Meters
System
Selftest
Util
1 - ANNUNCIATOR
2 - REMOTE
3 - VERSION
4 - DATE AND TIME
5 - HW CONFIG
6 - OPTIONS
7 - USB MANAGER
8 - UNIT COPY
SCREEN FEATURE
FUNCTION
1 - ANNUNCIATOR
Displays the Annunciator Screen (para 2-2-5A).
2 - REMOTE
Displays the Remote Screen (para 2-2-5B).
3 - VERSION
Displays the Version Screen (para 2-2-5C).
4 - DATE / TIME
Displays the Date / Time Screen (para 2-2-5D).
5 - HW CONFIG
Displays the HW Config Screen (para 2-2-5E).
6 - OPTIONS
Displays the Options Screen (para 2-2-5F).
7 - USB MANAGER
Displays the USB Manager Screen (para 2-2-5G).
8 - UNIT COPY
Displays the Unit Copy Screen (para 2-2-5H).
F2 “Meters”
Displays the Meters Menu (para 2-2-3).
F3 “System”
Displays the System Menu (para 2-2-2).
F4 “Selftest”
Displays the Self Test Menu (para 2-2-4).
F5 “Util”
Displays the Utilities Menu (para 2-2-5).
Subject to Export Control, see Cover Page for details.
A.
Annunciator Screen
When the Utilities Menu is displayed, press the 1 Key to access the Annunciator Screen:
Edit
Return
ANNUNCIATOR
Alarm:
On
Key Press:
Off
PTT:
Off
41 20 29
SCREEN FEATURE
FUNCTION
Alarm
Used to enable the audible alarm.
Select:
On or Off
Key Press
Used to enable the audible tone on each key press.
Select:
On or Off
PTT
Used to enable the audible tone when the PTT is pressed on the
microphone.
Select:
On or Off
F1 “Edit” / “Done”
Edit
Highlights the selected field to be changed or changes the
field value if the field only contains two selections.
Done
Ends the Field Edit and saves the new setting / value.
F2 “Return”
Displays the Utilities Menu (para 2-2-5).
F5 “Esc”
Ends the Field Edit, but does NOT save any changes to the setting or