Digigram VX442e Operation & User’s Manual
Read Online
Read the Digigram VX442e Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
For technical support,
please contact your system supplier.
Digigram S.A.
82/84 Allée Galilée, 38330 Montbonnot-Saint-Martin, FRANCE
Tel: +33 (0)4 76 52 47 47• Fax: +33 (0) 4 76 52 18 44• E-mail: [email protected]
Digigram Asia Pte Ltd.
60 Albert Street, #09-11 OG Albert Complex, Singapore 189969
Tel: +65 6291 2234 • Fax: +65 6291 3433 • E-mail: [email protected]
2
VX442e User manual
Table of Contents
INFORMATION FOR THE USER
5
IMPORTANT NOTICE
6
CONTENTS OF THIS PACKAGE
6
FEATURES
6
VX442e main hardware features
7
Main software features
7
Minimum hardware requirements
8
Software requirements
8
Supported operating systems
8
HARDWARE INSTALLATION
9
Installing the card
9
Interrupt and memory address
9
SOFTWARE INSTALLATION
10
Standard installation under Windows
10
Digigram Control Center
12
ASIO Control Panel
13
How to check the installation
14
The ‘Digigram Hardware Settings’ (‘DHS’) panel
15
SPECIFICATIONS
16
Configuration
16
Inputs
16
Outputs
17
Connectors
17
Audio specifications
17
Audio performance
18
Development environments
18
APPENDICES
19
VX442e schematic diagram
19
3
68-pin SCSI connector pinout
21
Cable delivered by Digigram
22
Breakout cable schematic
22
Breakout cable wiring diagram
23
Adapter cable Sub-D 62⬄ SCSI 68 MDR (before July 2015)
24
Adapter cable Sub-D 62⬄ SCSI 68 MDR (since July 2015)
24
Cable for connection to BoB8 (before July 2015)
25
Cable for connection to BoB8 (since July 2015)
25
Copyright 2008 Digigram. All rights reserved.
No portion of this manual may be reproduced without prior written consent from Digigram. The copyright protection
claimed here includes photocopying, translation and/or reformatting of the information contained in this manual.
While every effort has been made to ensure accuracy, Digigram is not responsible for errors and omissions, and
reserves the right to make improvements or changes in the products and programs described without notice.
Digigram and the Digigram logo, and VX442e are registered trademarks or trademarks of Digigram S.A. Other
trademarks are property of their respective holders.
4
VX442e User manual
INFORMATION FOR THE USER
This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a CLASS
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions contained
in this data sheet, may cause harmful interference to radio and television
communications. However, there is no guarantee that interference will not occur in
a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
* reorient or relocate the receiving antenna
* increase the separation between the equipment and the receiver
* connect the equipment into an outlet on a circuit different from that of the
receiver
* consult the dealer or an experienced audio television technician.
Note:
Connecting this device to peripheral devices that do not comply with
CLASS B requirements or using an unshielded peripheral data cable could also
result in harmful interference to radio or television reception. The user is
cautioned
that any changes or modifications not expressly approved by
the party responsible
for compliance could void the user’s authority to
operate this equipment. To ensure
that the use of this product does not
contribute to interference, it is necessary to use
shielded I/O cables.
Warning:
Electrostatic
discharge
(ESD)
can
damage
several components on the board. To avoid
such damage in handling the board, take the
following precautions:
Bring the device and everything that contacts it
to ground potential by providing a conductive
surface and discharge paths. As a minimum, observe these precautions:
●
Disconnect all power and signal sources.
●
Place the device on a grounded conductive work surface.
5
Ground yourself via a grounding wrist strap or by holding a
grounded object.
●
Ground any tool that will contact the device.
Due to the reduced length of the PCI EXPRESSTM bus connector and the
resulting lack of mechanical stability, we strongly advise against
transporting the PCIe® card(s) installed in a computer, unless its chassis or
case provides a dedicated support to keep the card securely in place in
order to avoid physical damage.
IMPORTANT NOTICE
This card has been tested and found to comply with the following
standards:
●
International: CISPR22 Class B
●
Europe: EMC 89/336/CEE (1992) specifications
●
United States: FCC Rules-Part 15-Class B (digital device)
In order to guarantee compliance with the above standards in an
installation, the following must be done:
●
the provided cable must not be modified
●
additional cables used must have their respective shield connected
to each extremity
CONTENTS OF THIS PACKAGE
Thank you for purchasing a Digigram sound card.
In its OEM version, the card is delivered without the breakout cable.
6
VX442e User manual
FEATURES
The VX442e is an audio card for PCI EXPRESSTM (PCIe®) bus. It is in
PCI EXPRESSTM x1 format and can thus be plugged into any PCIe® slot
(x1, x2, x4, x8, x16, x32).
VX442e main hardware features
●
4 balanced ∗ analog mono line inputs, with software programmable
1
analog and digital gain
●
4 servo-balanced ∗∗ analog mono line outputs, with software
2
programmable analog and digital gain
●
192 kHz / 24-bit converters
●
Maximum level on analog inputs and outputs: +24 dBu
●
2 AES/EBU ∗∗∗ stereo inputs, with hardware sample rate converters
3
(up to 192 kHz)
●
2 AES/EBU∗∗∗ stereo outputs (up to 192 kHz)
●
1 AES/EBU∗∗∗ stereo sync input (up to 192 kHz)
●
1 standard Word Clock input (up to 96 kHz)
●
1 standard Word Clock output (up to 96 kHz)
●
1 video sync input
●
1 SMPTE/LTC (Linear Time-code) input
Main software features
●
Real-time, simultaneous record and playback in PCM (8, 16 and 24
bits), Float IEEE754 conversion supported (with 24-bit fixed-point
dynamic range)
●
When using the np SDK, real-time mixing of several PCM audio
streams, direct monitoring, level adjustment, panning, cross-fades,
punch-in/punch-out, scrubbing
●
Low latency drivers.
1∗ can be used with unbalanced signals
2∗∗ electronically servo-balanced outputs provide automatic level adjustment to
accommodate either balanced or unbalanced lines
3∗∗∗ can be used as S/PDIF interface as well
7
Minimum hardware requirements
PCI EXPRESS™ (PCIe®) slot (x1, x2, x4, x8, x16 or x32).
CPU power and memory required depend on the operating system and
on the audio application used.
Software requirements
To use your VX442e, install the driver from the HR Runtime package
version 1.72 or higher. This package includes:
●
a Digigram np driver enabling OEM applications to best
capitalize on the boards
●
a WDM DirectSound driver
●
a Wave driver (under Windows XP and Server 2003 only. As of
Windows 7, Wave devices are not supported by Windows)
●
an ASIO driver (optional installation)
Note: the HR Runtime package for Windows Vista does not include a
Wave driver. In case your audio application explicitly requires a
Wave interface, a Wave driver is available on request. In this case,
please contact Digigram.
Supported operating systems
The VX442e runs under Windows and Windows Server versions as of
Windows XP and Server 2003.
8
VX442e User manual
HARDWARE INSTALLATION
Due to the reduced length of the PCI EXPRESS™bus connector and the
resulting lack of mechanical stability, we strongly advise against transporting the
PCIe® card(s) installed in a computer, unless its chassis or case provides a
dedicated support to keep the card securely in place in order to avoid physical
damage.
The card has to be installed in the computer prior to installing its driver.
Installing the card
Gently plug the card in a free PCI slot and press it down to position it
firmly. Tighten the screw.
Interrupt and memory address
Hardware interrupt and addresses are automatically set up at start-up by
the PCI PnP BIOS.
9
the installation of the software requires administrator rights
on your computer
Please visit the Digigram web site at www.digigram.com for the most
recent driver.
In case you run a specific application developed or installed by a
Digigram Partner, this application might require the use of a specific
driver version. In this case, make sure that the updated driver has been
approved by your supplier.
Standard installation under Windows
If the driver has been downloaded from our web site, it has to be
expanded prior to the driver’s installation as follows: double-click on the
downloaded file (self-expanding). You can use the default destination
location (Windows temporary folder) or select another directory.
Important note: this default procedure installs the ‘Digigram Hardware
Settings’ control panel. This application allows the configuration of the
hardware resources of Digigram cards for all audio applications. The DHS
allows for instance to define the clock of the card, the input source, input and
output analog and digital gain, Sample Rate Converters, digital output format,
etc...
Please note that, with the DHS installed, controls available through the
DirectSound control panel are limited to:
●
Volume control for input and output
●
Wave control
Under Windows XP and Server 2003 you may also install the driver without
installing the DHS control panel, and in this case more controls are available
through the DirectSound control panel:
●
Volume control for input
●
Wave control
●
Monitoring control
●
Analog input level
●
Digital input level
●
Clock selection: AES Sync, AES1, Word Clock
●
Digital output format: professional, consumer
10
VX442e User manual
To do so, install the driver with the command line: “setup x_topology” (not
available under Windows Vista). For detailed information, please refer to the
dedicated document on our web site.
●
Shutdown your computer and insert your VX card.
●
Restart your computer.
●
Click on Cancel if the Found New Hardware Wizard appears.
●
Double-click
on
the
HR
Runtime
vxx.msi/HR
Runtime
vxx.msi for Vista icon to launch the driver installation.
●
A welcome message is displayed, click Next to continue.
●
The “License Agreement” window appears: read it, and click
on
“I accept the terms in the license agreement” to approve it.
●
Do the same in the next window for Virtual PCX and PC Codec
Legal Notice.
●
In the “Custom Setup” window, the “Drivers for the HR
boards” are displayed; by default, both WDM DirectSound and
ASIO HR are installed.
To install the Wave driver ∗, select ‘Wave’.
4
To be able to use your VX card through np, select the
‘Digigram np’ component option (or make sure that the np
application explicitly sets the ‘VX_FLAG’ with PCXInitialize()).
Next.
●
In the “Ready to Install the Program Window”, click on Install to
start copying the files.
●
Note: In case you use an unsigned driver version,
the “Digital Signature Not Found” message may
appear because a non-Microsoft software is about
to be installed.
Click on Continue in the “Hardware installation”
window (Windows XP, Server 2003).
●
Under Windows Vista:
Click Allow in the “User Account Control” window.
Click Install in the “Windows Security” window.
●
In the “Digigram drivers” window, select the number and the
size of buffers required by your applications. Click on Ok.
●
Click Finish to complete the driver installation.
4∗ Windows XP and Server 2003 only; for Windows Vista, a Wave driver is
available on request.
11
Digigram Control Center
This control panel allows to define:
●
the number of buffers and their size
●
the granularity
Please note that for all sound cards of the VX range, “PCM only” is the
only operating mode, therefore this button is not functional in the
Digigram control panel (CPL). (To access this control panel, go to
, , , ).
For detailed information on how to use the Digigram control panel,
please refer to its online help (“? Help” button).
12
VX442e User manual
ASIO Control Panel
To launch the ASIO control panel, go to , ,
, .
It allows to:
●
set/modify the size of ASIO buffers (and thus latency)
●
select the number of bits per sample (16 or 24)
●
select the LTC frame rate
●
select the I/O used
●
enable/disable the hardware monitoring control
For more information on this ASIO control panel, please refer to its
online help.
Removing the driver under Windows XP and Windows
Server 2003
●
Open the Windows Control Panel and double-click on the
Add/Remove Software icon.
●
Select “Digigram HR Runtime …”, and Change/Remove.
●
Select Remove in the HR Runtime window.
●
Follow the instructions to finish to remove the driver.
Removing the driver under Windows Vista
●
Open the Windows Control Panel and double-click on the
Programs and Features icon.
●
Select
“Digigram
HR
Runtime
for
Vista…”,
and
Change/Remove.
●
Select Remove in the HR Runtime window.
●
Follow the instructions to finish removing the driver.
13
How to check the installation
Once the cards and the driver have been installed according to the
procedure described in this manual, you can verify that the card is
properly installed and works fine as follows:
●
Menu , , tab “Audio”, Default device (Playback device,
Recording device). The card’s channels can be selected. The
card can be used with any DirectSound application.
Available WDM devices are:
●VX442e 1+2 (WDM) (record and playback)
●VX442e 3+4 (WDM) (record and playback)
●
The card is also visible via the np interface: go to
and
select
.
●
In the “Digigram drivers” window, select the ‘General
Information’ tab.
In the “Modules Information” window, you can see the HR
Runtime modules that have been installed, and their versions.
●
In the “Digigram drivers” window, select the ‘Diagnostics’ tab.
You should see here the icons of the cards you have installed.
●
If the card you have installed is listed:
●
Right click on the icon of the card.
●Select ‘Diagnostics’, and Play Sine. This plays in loop a sine
signal on the outputs of the card. You can also select Play file
to play in loop a file of your choice (PCM only).
If the playback is correct, the card is correctly installed and
works.
●To stop the playback, right click on the card icon, and select
Stop Activities.
●
If the card is not displayed:
●Make sure that during the HR runtime installation the “Driver
for the HR boards” has been selected in the “Select
components” window.
●Make sure that the card is correctly inserted in the PCI slot, and
screwed on the PC chassis.
●If necessary, uninstall the HR runtime package as described in
this manual, and re-install it.
●
If the Wave driver has been installed ∗:
5
5 ∗ Windows XP and Server 2003 only; for Vista, a Wave driver is available on
request.
14
VX442e User manual
● Go to menu , , , , tab “Audio”, Default device (Playback
device, Recording device). The card’s channels can be
selected. The card can be used with any Wave application.
Available Wave recording and playback devices are:
●
VX442e 1+2 (Wave) (record and playback)
●
VX442e 3+4 (Wave) (record and playback)
●
If the ASIO driver has been installed:
●
The card is visible from any ASIO application.
The ‘Digigram Hardware Settings’ (‘DHS’) panel
Digigram
Hardware
Settings
(DHS) is an application allowing to
configure the hardware resources of Digigram cards for all audio
applications using them.
A resource being managed by the DHS application can not be modified
by any other applications. To enable an audio application to modify a
Digigram card resource, this resource must not be managed by the
DHS.
Note: As soon as a resource of a card is managed by the DHS,
the clock selection of this card MUST be defined in the DHS.
The DHS allows to:
●
Select the clock the card uses
●
Select the input source
●
Adjust analog and digital gains of inputs and outputs
●
Enable Sample Rate Converters of an input
●
Select the input monitored on an output
●
Set the monitoring gains
●
Define the digital output format
For more detailed information on how to use this control panel, please
refer to its on-line help.
15
PCI Express™ (PCIe®) x1
(x2, x4, x8, x16, x32 compatible)
Size
168 mm × 111 mm x 20 mm
Power requirements
(+3.3V / +12V)
2.5 A / 0.1 A
Operating: temp / humidity
(non-condensing)
0°C/+50°C • 5%/90%
Storage: temp / humidity
(non-condensing)
-5°C/+70°C • 0%/95%
Inputs
VX442e
Analog line inputs (mono)
4 balanced∗
Maximum input level/
impedance
+24 dBu/ >10 kΩ
AES/EBU ∗∗ inputs
6
(stereo)
2 with switchable hw sample rate
converters,
ratio 1:8 to 7,5:1,
up to 192 kHz
Programmable input gain
analog: from –94.5dB à +15.5 dB ⊗
7
digital: from –110 dB à +18 dB
Other inputs
AES/EBU Sync (up to 192 kHz),
Word clock (up to 96 kHz), LTC, Video
AES11 synchronization
Yes
6∗∗ can be used as S/PDIF interface as well
7⊗ maximum sensitivity: 0 dBFs for –15.5 dBu input
16
VX442e User manual
Outputs
VX442e
Analog line outputs
(mono)
4 servo-balanced ∗
8
Maximum output level /
impedance
+24 dBu / <100 Ω
Digital outputs (stereo)
2 AES/EBU ∗∗, up to 192 kHz
9
Programmable output
gain
analog: from –86 dB to +24 dB
digital: from –110 dB to +18 dB
Other output
Word clock (up to 96 kHz)
Connectors
VX442e
Internal connectors
Inter-board Sync
External connector
68-pin SCSI MDR
Digigram accessories
available
Breakout cable or 2U 19“ Breakout Box
Audio specifications
VX442e
Sampling frequencies
available
Programmable from 32 to 192 kHz
A/D and D/A
converter resolution
24 bits
Supported audio
formats
PCM (8, 16, 24 bits), Float IEEE754
8∗ electronically servo-balanced outputs provide automatic level adjustment to
accommodate either balanced or unbalanced lines
9∗∗ can be used as S/PDIF interface as well
17
Measurements done at Fs=48 kHz unless stated otherwise,
with filter on the 22 Hz - 22 kHz range
VX442e
Frequency response
(record + play)
20 Hz–20 kHz: ±0.2 dB
Channel phase
difference: 20/20kHz
<0.2°/2°
Dynamic range
(A-weighted)
Analog In: >104 dBA
Analog Out: >104 dBA
THD + noise 1 kHz
at –1 dBfs
Analog In: <–97 dB
Analog Out: <–94 dB
THD + N 1 kHz AES/EBU
In w/ SRC
<-130 dB
Crosstalk (Analog in or
out)
1 kHz at 24 dBu: <–100 dB
15 kHz at 24 dBu: <–85 dB
Development environments
VX442e
Digigram management
np SDK (HR Runtime, PCM)
Other management
Wave
∗,Wasapi, DirectSound, ASIO, (all
10
PCM)
OS supported
Windows and Windows Server versions
as of XP and Server 2003 (32 & 64 bits)
Main on-board
processing features (with
np SDK)
PCM play & rec, Float IEEE754,
direct monitoring, real-time mixing,
level adjustment, panning, cross-fade,
punch-in/punch-out, scrubbing
10 ∗ Windows XP and Server 2003 only; for Windows Vista, a Wave driver is available
on request.
18
J1: 68-pin SCSI MDR female I/O connector
J1 before July 2015
J1 connector is fixed to the card
bracket using Philips screws, and
is adapted to clip themale SCSI
connector of the cable.
J1 after July 2015
The connector is fixed to the card
bracket using locking screws.
The male SCSI connector of the
cable is now screwed in the
locking screws.
20
VX442e User manual
68-pin SCSI connector pinout
D
i
g
i
t
a
l
Pin Signal
Pi
n
Signal
Pi
n
Signal
1
AES/EBU IN 4 +
11
AES/EBU OUT 2
+
41
GND
2
AES/EBU IN 4 -
12
AES/EBU OUT 2
-
42
GND
3
AES/EBU SYNC +
15
Video IN
43
4
AES/EBU SYNC -
16
GND
44
5
AES/EBU IN 2 +
35
45
AES/EBU OUT 1 +
6
AES/EBU IN 2 -
36
46
AES/EBU OUT 1 -
7
GND
37
Reserved
47
Word Clock IN
8
GND
38
Reserved
48
GND
9
39
AES/EBU IN 1 +
49
Word Clock OUT
10
40
AES/EBU IN 1 -
50
GND
A
n
a
l
o
g
Pi
n
Signal
Pi
n
Signal
Pi
n
Signal
13
LTC IN
28
57
OUT 1 +
14
GND
29
58
OUT 1 +
17
30
59
GND
18
31
IN 4 +
60
GND
19
32
IN 4 -
61
20
33
IN 2 +
62
21
OUT 4 +
34
IN 2 -
63
22
OUT 4 -
51
64
23
OUT 2 +
52
65
IN 3 +
24
OUT 2 -
53
66
IN 3 -
25
GND
54
67
IN 1 +
26
GND
55
OUT 3 +
68
IN 1 -
27
56
OUT 3 -
21
Cable delivered by Digigram
The cable for VX442e consists in two parts: the breakout cable, and the
SCSI <-> Sub-D adapter.
Breakout cable schematic
22
Adapter cable Sub-D 62⬄SCSI 68 MDR (before July
2015)
Adapter cable Sub-D 62⬄SCSI 68 MDR (since July
2015)
24
VX442e User manual
Cable for connection to BoB8 (before July 2015)
Cable for connection to BoB8 (since July 2015)
25