EMC2 Avamar Gen4S Installation Manual

Specifications

Brand: EMC2
Category: Computer Hardware
Model: Avamar Gen4S
File Type: PDF
File Size: —
Pages: 50

Read Online

Read the EMC2 Avamar Gen4S Installation Manual online using the built-in PDF viewer.

Text of the manual

Copyright © 2001-2016 EMC Corporation. All rights reserved. Published in the USA.

Published May, 2016 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC², EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com). EMC Corporation Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.EMC.com 2 EMC Avamar Data Store Gen4S Customer Installation Guide

Important terms and concepts.......................................................................10

Nodes.............................................................................................. 10 Utility node...................................................................................... 10 Storage nodes..................................................................................10 Single-node servers......................................................................... 10 Extended retention media access node............................................10 NDMP accelerator node....................................................................11 Node resource database (probe.xml)................................................11 Avamar Downloader Service.............................................................11 Local downloader service.................................................................11 Avamar FTP site................................................................................11 Avamar Installation Manager............................................................11 Avamar login manager..................................................................... 11 Packages......................................................................................... 12 Bonded network interfaces.............................................................. 12 High-availability network .................................................................12 ConnectEMC.....................................................................................12 Email home......................................................................................13 EMC repository.................................................................................13 Local repository............................................................................... 13 Manifest file.....................................................................................13 Information for customers............................................................................. 13 Fundamental Avamar principles....................................................... 14 Avamar 7.x installation features overview......................................................14 How long will the Avamar software installation take?........................14 Avamar Installation Manager............................................................15 Process flow.....................................................................................15 Log files........................................................................................... 16 In-flight encryption...........................................................................16 Avamar Downloader Service.............................................................16 Hardware Specifications 19 Hardware specifications................................................................................20 M600 (2.0 TB licensed capacity)...................................................... 20 M1200 (3.9 TB licensed capacity).................................................... 20 M2400 (7.8 TB licensed capacity).................................................... 20 Avamar Business Edition/S2400 node (7.8 TB licensed capacity).....20 Service port connectivity............................................................................... 20 M600, M1200, and M2400.............................................................. 21 S2400..............................................................................................21 Node components.........................................................................................21 M600, M1200, M2400, and Avamar Business Edition (S2400) Nodes ........................................................................................................ 22 Preface Chapter 1 Chapter 2 CONTENTS EMC Avamar Data Store Gen4S Customer Installation Guide 3

Basic networking configuration..................................................................... 26

Supported network configurations................................................................ 27 Single-node servers......................................................................... 27 Advanced network configuration – dpnnetutil utility......................................29 Features provided by dpnnetutil.......................................................30 Replication....................................................................................................30 Single-node servers......................................................................... 30 Installation Prerequisites 33 Important notices..........................................................................................34 Prerequisites.................................................................................................34 Site and environmental requirements...............................................34 Required tools, equipment, software, and information..................... 34 Verifying checksums........................................................................ 36 Mounting the Single-Node Server 37 How to begin.................................................................................................38 Rail assembly kit...........................................................................................38 Hardware Installation....................................................................................38 System Preparation 43 Preparing the server for software installation.................................................44 Chapter 3 Chapter 4 Chapter 5 Chapter 6 CONTENTS 4 EMC Avamar Data Store Gen4S Customer Installation Guide

As part of an effort to improve its product lines, EMC periodically releases revisions of its

software and hardware. Therefore, all versions of the software or hardware currently in use may not support some functions that are described in this document. The product release notes provide the most up-to-date information on product features. Contact your EMC technical support professional if a product does not function correctly or does not function as described in this document. Note This document was accurate at publication time. Go to EMC Online Support (https:// support.emc.com) to ensure that you are using the latest version of this document. Purpose This publication describes how to configure and install a new Avamar Data Store (ADS) Gen4S single-node server. Implementation is typically performed remotely by EMC personnel. Audience The information in this publication is primarily intended for persons responsible for configuring and installing ADS Gen4S. Installation in this context is the physical rack and stack, power, cable, and initial network configuration required to facilitate software implementation done by EMC personnel or an authorized partner. EMC field personnel and partners should use SolVe Desktop documentation. Revision history The following table presents the revision history of this document. Table 1 Revision history Revision Date Description 01 October 25, 2012 Q4 Data Store Release 01 version. 02 February 11, 2013 Gen4S General Availability Release 02 version. 03 July 10, 2013 Initial release of Avamar 7.0 04 May 9, 2016 Avamar 7.3 and Gen4T General Availability Related documentation The following EMC publications provide additional information: l EMC Avamar Data Store Customer Service Guide Special notice conventions used in this document EMC uses the following conventions for special notices: DANGER Indicates a hazardous situation which, if not avoided, results in death or serious injury. EMC Avamar Data Store Gen4S Customer Installation Guide 5

Indicates a hazardous situation which, if not avoided, could result in death or serious

injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Addresses practices that are not related to personal injury. Note Presents information that is important, but not hazard-related. Typographical conventions EMC uses the following type style conventions in this document: Table 2 Typographical conventions Bold Used for names of interface elements, such as names of windows, dialog boxes, buttons, fields, tab names, key names, and menu paths (what the user specifically selects or clicks) Italic Used for full titles of publications referenced in text Monospace Used for: l System code l System output, such as an error message or script l Pathnames, file names, prompts, and syntax l Commands and options Monospace italic Used for variables Monospace bold Used for user input [ ] Square brackets enclose optional values | Vertical bar indicates alternate selections - the bar means “or” { } Braces enclose content that the user must specify, such as x or y or z ... Ellipses indicate nonessential information omitted from the example Where to get help The Avamar support page provides access to licensing information, product documentation, advisories, and downloads, as well as how-to and troubleshooting information. This information may enable you to resolve a product issue before you contact EMC Customer Support. To access the Avamar support page: 1. Go to https://support.EMC.com/products. 2. Type a product name in the Find a Product by Name box. 3. Select the product from the list that appears. Preface 6 EMC Avamar Data Store Gen4S Customer Installation Guide

4. Click the arrow next to the Find a Product by Name box.

5. (Optional) Add the product to the My Saved Products list by clicking Add to My Saved Products in the upper right corner of the Support by Product page. Documentation The Avamar product documentation provides a comprehensive set of feature overview, operational task, and technical reference information. Review the following documents as well as product administration and user guides: l Release notes provide an overview of new features and known limitations for a release. l Technical notes provide technical details about specific product features, including step-by-step tasks, where necessary. l White papers provide an in-depth technical perspective of a product or products as applied to critical business issues or requirements. Knowledgebase The EMC Knowledgebase contains applicable solutions that you can search for either by solution number (for example, esgxxxxxx) or by keyword. To search the EMC Knowledgebase: 1. Click Advanced at the upper right corner of the page, next to the icon. 2. Type either the solution number or keywords in the search box. 3. (Optional) Limit the search to specific products by clicking Advanced, then typing a product name in the Scope by product box and then selecting the product from the list that appears. 4. Select Knowledgebase from the Scope by resource list. 5. (Optional) Specify advanced options and values in the available fields. 6. Click the icon. Online communities Go to EMC Community Network (https://community.EMC.com) for peer contacts, conversations, and content on product support and solutions. Interactively engage online with customers, partners, and certified professionals for all EMC products. Live chat To engage EMC Customer Support by using live interactive chat, click Join Live Chat on the Service Center panel of the Avamar support page. Service Requests For in-depth help from EMC Customer Support, submit a service request by clicking Create Service Request on the Service Center panel of the Avamar support page. Note To open a service request, you must have a valid support agreement. Contact your EMC sales representative for details about obtaining a valid support agreement or with questions about your account. To review an open service request, click the Expand link on the Service Center panel, click Manage Service Requests, and then click View and manage service requests. Preface EMC Avamar Data Store Gen4S Customer Installation Guide 7

EMC recommends that you enable ConnectEMC and Email Home on all Avamar

systems: l ConnectEMC automatically generates service requests for high priority events. l Email Home sends configuration, capacity, and general system information to EMC Customer Support. Your comments Your suggestions help EMC continue to improve the accuracy, organization, and overall quality of the user publications. Send your opinions of this document to [email protected]. Please include the following information: l Product name and version l Document name, part number, and revision (for example, 01) l Page numbers l Other details that help EMC address the documentation issue Preface 8 EMC Avamar Data Store Gen4S Customer Installation Guide

This chapter provides general information about Avamar terminology, an overview of

installation features for the Avamar Data Store (ADS), and a high-level road map of the installation. Topics in this chapter include: l Important terms and concepts...............................................................................10 l Information for customers..................................................................................... 13 l Avamar 7.x installation features overview..............................................................14 General Information 9

Important terms and concepts

This section provides a list of terms you can use to familiarize yourself with the Avamar family of hardware. Some of these terms, since they refer to multi-node Avamar systems, are not used anywhere else in this guide. Nodes The primary building block in any Avamar system is a node. Each node is a self- contained, rack-mountable, network-addressable server that runs Avamar software on the Linux operating system. All Avamar nodes are Domain Name System (DNS) clients. Note The term "server" in the previous definition is used in the typical industry context (that is, a computer that provides services to other computers or devices). However, for the remainder of this guide, unless otherwise specified, the term "server" is used to refer to a single node or multi-node Avamar system. The term "node" is used to refer to the individual computer/storage platforms that make up an Avamar server. All nodes run the Linux operating system and use RAID data protection. Nodes have 2, 6, 8, or 12 hard drives, depending on node type and storage capacity. The primary differences between node types are: l The amount of internal data storage (if any) l How internal data storage is configured and allocated (that is, RAID level, number of logical units [LUNs] and so forth) l The Avamar application software that is installed on each node type Utility node In scalable multi-node Avamar servers, a single utility node provides essential internal services for the server (for example, administrator server, replication, external authentication, network time protocol [NTP], and Web access). Because utility nodes are dedicated to running these essential services, they cannot be used to store backups. Storage nodes The remaining nodes in scalable multi-node Avamar servers are storage nodes, which store the actual backups. There are three storage node models, the primary difference being the amount of usable storage available: the M600, M1200, and M2400. They are also offered as single node Avamar servers. Single-node servers A single-node Avamar server, whose installation is described in this guide, combines all the features and functions of utility and storage nodes in a single node. In addition to the three storage nodes that were mentioned previously, EMC offers another model for single-node server usage: the Avamar Business Edition (S2400). Extended retention media access node The media access node exports backup data from an Avamar server to a tape library (physical or virtual) for long-term retention purposes. It has a 10GbE port and an HBA port General Information 10 EMC Avamar Data Store Gen4S Customer Installation Guide

that allows a tape device to be connected directly to the node via fiber-optic cable. It is

not part of an ADS server (not connected to the Avamar multi-node system’s internal network). For installation instructions, refer to the EMC Avamar Extended Retention Media Access Node Hardware Installation Guide. NDMP accelerator node An Avamar NDMP accelerator (accelerator node) is a dedicated single-node Avamar client that, when used as part of an Avamar system, provides a complete backup and recovery solution for supported EMC Isilon, VNX, VNXe, and Celerra systems, and NetApp filers by using Network Data Management Protocol (NDMP) to communicate with these storage devices. It is not part of the ADS server. For installation instructions, refer to the EMC Avamar NDMP Accelerator User Guide. Node resource database (probe.xml) An XML file that stores the types and IP addresses of Avamar server nodes. In addition, probe.xml stores the types and IP addresses of optional nodes, and supports both Network Address Translation (NAT) and multiple network interfaces. Avamar Downloader Service A Windows-based file distribution system that delivers software installation packages to target Avamar systems. Avamar Downloader Service provides more information. Local downloader service A component integrated into the Avamar Installation Manager. The local downloader service (LDLS) allows administrators to check the EMC repository for updated software packages by using the Avamar Installation Manager web interface. The LDLS supports environments where local Windows hosts are unavailable, removing the requirement to copy files directly to the local repository. Avamar FTP site An EMC FTP site that provides anonymous access to Avamar hotfixes and operating system (OS) patches. The FTP site is ftp://ftp.avamar.com. Typically, access to this site is for EMC personnel (there may be exceptions). The contents of the FTP site are not browsable. Avamar Installation Manager A web interface that manages installation, upgrade, and maintenance packages. Avamar Installation Manager on page 15 provides more information. Avamar login manager A process that provides access to an external authentication database, which enables the Avamar system to use existing username and password information for Avamar authentication. Without the login manager, Avamar can only use its internal authentication mechanism. An Avamar server installation or upgrade installs the login manager, and then starts it. The login manager uses the domains configuration file to identify the supported domains. General Information NDMP accelerator node 11

Avamar software installation files, hotfix patches, and operating system (OS) patches

available from the EMC repository. Packages comprise three types: l Client - A release of Avamar file system or application backup software. l Server - A new release of Avamar server software, a service pack, or a patch for the operating system, management console, or Avamar software. l Workflow - A package that runs operations such as replacing a node or changing the session security configuration. Package files use the extension .avp. Bonded network interfaces Bonded network interfaces are used in high-availability (HA) configurations that try to eliminate node ports and switches as single points of failure. Two separate customer network switches are required, one connected to each of two physical interfaces of an ADS node. Outgoing replication and management networks can be configured for bonding through the additional ports on the single-node server. High-availability network HA configuration provides for continued operation in the event of a single point of failure between network components. The primary objective is to provide multiple paths to the customer network so that the system can recover from an individual device or link failure. To do this, HA configuration employs bonded network interfaces that connect to two customer network switches. Each switch is connected to one of two physical interfaces of an ADS node. ConnectEMC A Linux-based program that transfers event data from an Avamar server to EMC Technical Support. Installation of the Avamar software automatically initializes ConnectEMC by passing values from the workflow to the ConnectEMC configuration files. The server software installation requires you to set the ConnectEMC attributes listed in the following table: Table 3 ConnectEMC attributes Attribute Example setting Site name ABC Company, Site ID: 123456 Address: 123 Main Street, Anytown, CA 92618 US Email server mail.example.com Email sender address [email protected] You can set other ConnectEMC attributes after the installation by using Avamar Administrator. Additional information about ConnectEMC is available from the following resources: l EMC Avamar Administration Guide l ConnectEMC for Linux 3.0 Reference Guide General Information 12 EMC Avamar Data Store Gen4S Customer Installation Guide

An Avamar feature that automatically emails configuration, capacity, and general system

information to EMC Technical Support once daily, and critical alerts in near-real time on an as-needed basis. Email home uses the same email server that you configure for ConnectEMC. EMC repository A repository that contains server installation packages, client installation packages, and manifest files. The EMC repository currently spans two locations: ftp://ftp.avamar.com and EMC Subscribenet: l High urgency packages such as hot fixes and OS patches are available from ftp:// ftp.avamar.com. l Low urgency packages that have security and entitlement considerations are available from EMC Subscribenet. The actual source location of a package is transparent to the user. The repository is located on the EMC network. Each EMC customer has its own download center that contains files available to it. These files are maintained by the EMC Subscribenet team. Outgoing communication from the Avamar Downloader Service and LDLS to the EMC repository is encrypted with SSL over an HTTP connection. Local repository The /data01/avamar/repo/packages directory on the utility node or single-node server. The directory contains the most current manifest file from the EMC repository, installation packages, and workflow packages. The Avamar Downloader Service and LDLS push packages from the EMC repository to the local repository. If a customer site does not allow Internet access, you can manually copy packages into the local repository. Manifest file An XML file listing all packages currently available for download from the EMC repository. When the EMC Subscribenet team adds a package to the EMC repository, it then adds an entry to the manifest file that describes the package. When the EMC Subscribenet team removes the package from the repository, it then removes the entry for the package from the manifest file. The Avamar Downloader Service automatically downloads the manifest file from the EMC repository once a day and determines if new download packages are available. The Avamar Downloader Service sends the new manifest file to the local repository for each Avamar system. The LDLS manages changes to the manifest file in a similar way to the Avamar Downloader Service. However, the LDLS downloads the manifest file directly to each Avamar system without the requirement for an intermediate host. Information for customers The following is a collection of information about Avamar and the ADS that can guide you when installing and using this product. The EMC Online Support site is a great resource for information and links: https:// support.emc.com/products/ General Information Email home 13

Avamar software downloads are located on the Avamar FTP site: ftp://ftp.avamar.com

Obtaining an Avamar license key file requires an account for the EMC Software Licensing Central (SLC) on the EMC Online Support site. EMC Technical Support is responsible for obtaining a license key file for your system. For information about cross-version and cross-equipment compatibility, refer to the EMC Avamar Compatibility and Interoperability Matrix on the EMC Online Support site. For numerous best-practice tips about installing, configuring, upgrading, and using Avamar, refer to the EMC Avamar Operational Best Practices Guide on the EMC Online Support site. Numerous technical notes provide supplemental information about rare, unique, or version-specific installation, implementation, and configuration scenarios. Find technical notes by title on the EMC Online Support site. For instance, one technical note, Avamar Client Downloads and Client Manager Installer Upgrades Technical Note, describes how to upgrade client downloads and Avamar Client Manager client installers. Note Starting in Avamar 7.2.x, Avamar Enterprise Manager is no longer available. The technical note Avamar Enterprise Manager Transition to Backup and Recovery Manager provides more information. Fundamental Avamar principles When working with Avamar, always consider the following: l The best practice for replication is to move data from an older generation Avamar server to a newer one and not the reverse. This scenario is typically used to replicate data from the old server as a first step before upgrading it to the latest version of Avamar software, after which the data can be replicated back. l All single-node servers must be replicated, except the S2400 (Avamar Business Edition). Avamar 7.x installation features overview EMC personnel install the Avamar software after you complete the preliminary hardware installation and configuration described in this guide. The Avamar Installation Manager automates the software installation process on servers. EMC Technical Support uses this utility during implementation. Avamar 7.x also includes the Avamar Downloader Service, a Microsoft Windows-based application that automates the installation of future patches and other packages to your Avamar system. Starting in Avamar 7.3, the LDLS is also available for direct download of packages. How long will the Avamar software installation take? Completing the Avamar server software installation takes about two hours, plus the amount of time it takes to upload the Avamar software installation packages to the server. General Information 14 EMC Avamar Data Store Gen4S Customer Installation Guide

Uploading the installation package can take a significant amount of time, depending on

the method used. Installing and configuring the Avamar Downloader Service and LDLS are considered post-installation tasks because they are not required to perform Avamar software installation. Avamar Installation Manager During installation, the Avamar Installation Manager user interface is installed on the utility node or single-node server. The Avamar Installation Manager user interface enables EMC personnel to: l Install or upgrade the Avamar software l Install OS, Avamar software, or other hotfix patches after initial Avamar software installation Avamar Installation Manager controls the following: l The EMC repository manifest file l Downloading of packages from the Avamar Downloader Service and LDLS l Monitoring the local repository for any software packages manually added to the server l Dependency and version checks of the downloaded packages l Management of the temporary directory that is used to extract the packages l Deletion of software packages after a successful installation or upgrade Process flow The following diagram shows how the Avamar Downloader Service, LDLS, and Avamar Installation Manager work together with other components to automatically provide installation, upgrade, and hot fix packages. Figure 1 Process Flow for Packages Process flow tasks: General Information Avamar Installation Manager 15

1. The Avamar Downloader Service or LDLS checks with the EMC repository for new

manifest files. This check is done automatically every 24 hours. l The Avamar Downloader Service downloads the manifest from the EMC repository and pushes it to the Avamar Installation Manager, or l The LDLS downloads the manifest from the EMC repository directly to the Avamar Installation Manager. Note During the first communication handshake between the Avamar Downloader Service and Avamar Installation Manager, the Avamar Downloader Service passes information such as its version, its host and IP address, and so forth, to the Avamar Installation Manager. 2. The Avamar Installation Manager processes the manifest file and notifies the user of new packages. 3. The user requests the package by clicking the Download button in the Avamar Installation Manager. l The Avamar Downloader Service then downloads the package and pushes it to the Avamar Installation Manager, or l The Avamar Installation Manager downloads the package directly using the LDLS. 4. The user installs the package by clicking the Install button in the Avamar Installation Manager. Log files The Avamar Installation Manager provides log file information through the web interface. The log information can be exported to a file (.xls or .pdf). The Avamar Installation Manager also provides the Download all system logs icon , which enables you to download all system log files for troubleshooting issues, for example. You must log in to the EMC Customer Support account to use the Download all system logs icon. In-flight encryption A new installation of Avamar sets in-flight encryption to High as the default setting. An upgrade does not change the current in-flight encryption setting. The EMC Avamar Administration Guide provides more information about in-flight encryption. Avamar Downloader Service The Avamar Downloader Service is a file distribution system that delivers software installation packages to target Avamar systems. The distribution process uses minimal bandwidth by downloading only files that you request through the Avamar Installation Manager. The Avamar Downloader Service uses a local file cache to ensure that a file is fetched only once from the EMC repository, no matter how many times an Avamar system requests the file. You can remove old files from the local repository to free disk space. General Information 16 EMC Avamar Data Store Gen4S Customer Installation Guide

Avamar Downloader Service security

The Avamar Downloader Service validates each package that it downloads to ensure that the package has been correctly signed and transmitted. The Avamar Downloader Service accepts incoming requests only from Avamar systems that are on a known systems list. The Avamar Downloader Service encrypts outgoing communication to the EMC repository by using SSL (Secure Socket Layers) over an HTTP connection. Note If the site prohibits access to the Internet, you can manually copy packages to the / data01/avamar/repo directory, and then move them to the /packages directory on the single-node server instead of using the Avamar Downloader Service. Avamar Downloader Service components This section describes the components of the Avamar Downloader Service. Table 4 Avamar Downloader Service components Component Description Avamar Downloader Service Windows service Monitors the EMC repository. When a package is available for the Avamar system, the Avamar Downloader Service service automatically downloads the package and pushes it to the local repository on the Avamar utility node or single-node server. Avamar Downloader Service monitor A process that provides status message about the Avamar Downloader Service. Moving the mouse over the tray icon displays status messages from the Avamar Downloader Service monitor. Right-clicking the icon displays these options: Configure Service Opens the Avamar Downloader Service configuration application. Open Repository Opens the local file cache directory on the Windows server (C:\Program Files\EMC\Avamar Downloader Service\repository). Run Diagnosis Runs a test of packages in the local manifest file and for network connectivity to the EMC repository. Check for New Packages Queries the EMC repository for a new manifest file. Show Advanced Settings Allows the input of new EMC repository credentials or the restoration of Avamar Downloader Service to default settings. Check for Updates Checks for an updated version of the Avamar Downloader Service software. General Information Avamar Downloader Service 17

Table 4 Avamar Downloader Service components (continued)

Component Description About Shows the version of the Avamar Downloader Service. Exit Closes the Avamar Downloader Service. The Avamar Downloader Service installation also creates: l A local repository in the installation directory. This directory is where the Avamar Downloader Service puts packages it fetches from the EMC repository. l A Start menu program group: EMC Avamar Downloader Service , where is the version of the Avamar system software that is installed on the server. The program group contains: n Avamar Downloader Service Configuration n Avamar Downloader Service Monitor l A desktop shortcut to the Avamar Downloader Service configuration application. General Information 18 EMC Avamar Data Store Gen4S Customer Installation Guide

This chapter contains information about the ADS hardware that relates to single-node

server installation. Topics in this chapter include: l Hardware specifications........................................................................................20 l Service port connectivity....................................................................................... 20 l Node components.................................................................................................21 Hardware Specifications 19

Each node runs the SuSE Linux Enterprise Server v11 SP1 operating system and features

a service port. See Service port connectivity on page 20 for more information. The M600, M1200, and M2400 can be used as single-node servers or as storage nodes within a multi-node server. The S2400 (Avamar Business Edition) is available only as a single-node server and does not require replication. The Extended Retention Media Access and NDMP Accelerator nodes are optional nodes associated with, but not part of, the Avamar server. M600 (2.0 TB licensed capacity) l Six 3.5” hard drives l Dual 750W power supplies l Eight 10/100/1000baseT GbE ports l RMM4 management port M1200 (3.9 TB licensed capacity) l Six 3.5” hard drives l Dual 750W power supplies l Eight 10/100/1000baseT GbE ports l RMM4 management port M2400 (7.8 TB licensed capacity) l Twelve 3.5” hard drives l One 2.5” SSD drive (internal mounting) l Dual 750W power supplies l Eight 10/100/1000baseT GbE ports l RMM4 management port Avamar Business Edition/S2400 node (7.8 TB licensed capacity) l Eight 3.5” hard drives l One 2.5” SSD drive (internal mounting) l Dual 750W power supplies l Eight 10/100/1000baseT GbE ports l RMM4 management port Service port connectivity For each node type, use the following service port information to determine how to connect to the node. Unless otherwise specified, connection to a node service port can only occur after the node has booted. Hardware Specifications 20 EMC Avamar Data Store Gen4S Customer Installation Guide

M600, M1200, and M2400

Table 5 M600, M1200, and M2400 service ports Node state Service port Service port IP address Kickstarted (straight from manufacturing) or rekickstarted NIC8 (eth7) 10.99.99.5 After Avamar multi-node installation Switch port 24 Use the internal network IP address assigned to the node during installation After Avamar single node installation NIC8 (eth7) 10.99.99.5 S2400 Table 6 S2400 service ports Node state Service port Service port IP address Kickstarted (straight from manufacturing) or rekickstarted NIC8 (eth7) 10.99.99.5 After Avamar single node installation NIC8 (eth7) 10.99.99.5 Node components Before handling ADS Gen4S equipment, first familiarize yourself with the Gen4S node types and component locations for your specific hardware. See the figures and tables that follow for details. Hardware Specifications M600, M1200, and M2400 21

M600, M1200, M2400, and Avamar Business Edition (S2400) Nodes

Figure 2 Front View Table 7 M600, M1200, M2400, and Avamar Business Edition (S2400) node front panel components Feature Description Service tag A pull-out label for serial number and other system information. Hard drives Hot swappable 3.5” hard drives: l M600 node - Six in the 0 through 5 drive locations. All others are blank. l M1200 node - Six in the 0 through 5 drive locations. All others are blank. l M2400 node - 12 in the 0 through 11 drive locations. l Avamar Business Edition (S2400) node - Eight in the 0 through 7 drive locations. All others are blank. Front control panel A set of buttons, controls, and indicators: l System ID button - Use to locate a particular node in the rack. When pushed, the LED on the front and the system status indicator on the back panel flash blue until the button is pushed again. l Non-Maskable Interrupt (NMI) button - Use to troubleshoot software and device driver errors. Press by using the end of a paper clip. When pressed, it puts the node in a halt state and issues the NMI. Use this button only if directed to do so by qualified support personnel. Hardware Specifications 22 EMC Avamar Data Store Gen4S Customer Installation Guide

Table 7 M600, M1200, M2400, and Avamar Business Edition (S2400) node front panel

components (continued) Feature Description l NIC activity LEDs - One LED per NIC on the back panel. Network link detected = LED solid on. Network activity = LED blinking according to activity. l System Cold Reset Button - Reboots and reinitializes the node. l System Status LED - Green or amber LED showing system health. Solid green indicates the node is booted and ready. All other states indicate a level of degraded status, which should be reported through Avamar systems. l Power Button with Integrated LED - Toggles system power on and off. l Hard Drive Activity LED - Indicates drive activity from onboard controllers. Figure 3 M600, M1200, M2400, and Avamar Business Edition (S2400) Node Rear View Table 8 M600, M1200, M2400, and Avamar Business Edition (S2400) node rear panel components Feature Description Power supply #1 750W power supply. Power supply #2 750W power supply. Fiber optic ports Dual Qlogic 8 Gbps fibre channel ports - connects a tape library or VTL to the node. NICs 1-8 10/100/1000baseT GbE ports. 10GbE ports Dual 10Gb Ethernet ports: l Left: NIC 9 (eth8) l Right: NIC 10 (eth9) Monitor port Connects a VGA display to the system. Serial port Connects a serial device to the system. USB ports Connects a USB device to the system. Hardware Specifications M600, M1200, M2400, and Avamar Business Edition (S2400) Nodes 23

Table 8 M600, M1200, M2400, and Avamar Business Edition (S2400) node rear panel

components (continued) Feature Description RMM4 port Dedicated management port for the RMM4 card. Hardware Specifications 24 EMC Avamar Data Store Gen4S Customer Installation Guide

This chapter provides a comprehensive description of optional networking features and

requirements for the ADS single-node server. Topics in this chapter include: l Overview...............................................................................................................26 l Basic networking configuration............................................................................. 26 l Supported network configurations........................................................................ 27 l Advanced network configuration – dpnnetutil utility..............................................29 l Replication............................................................................................................30 Networking 25

The information in this chapter is for reference only. If advanced network or replication

configuration is required, this chapter describes procedures that must be performed by EMC personnel before Avamar software installation can be done. Included in this chapter are: l General overview of ADS networking principles related to single-node servers l Descriptions of the different network configurations supported by single-node servers l An overview of the optional dpnnetutil advanced configuration utility l Descriptions of replication schemes supported by single-node servers Unlike multi-node servers, the Avamar single-node server has no internal network functionality. The eth1 port (NIC2) is not dedicated to Avamar-specific traffic. Customers typically provide network switching and connections to match their infrastructure for backups, replication, and node management. For the ADS external network, default settings are: l The server is connected directly to customer network switches through NIC1 (eth0) and NIC3 (eth2) ports (bonded as bond0) by default for backing up customer data. l NIC1 is the primary, NIC3 is the secondary (failover). l If RMM4 functionality is used and set to shared, the default shared port is NIC1 (eth0). The preceding default settings can be changed through the dpnnetutil utility described in Advanced network configuration – dpnnetutil utility on page 29. Default network configuration is performed during Avamar software installation. Basic networking configuration ADS Gen4S single node servers follow these configuration principles: l All networking ports are bonded in pairs, by default. l For single-node servers, NIC1 (eth0) and NIC3 (eth2) port bonding can be broken to facilitate incoming replication, which is delivered directly to the server, or for server management. If this bond is broken, high availability backup capability is not possible. l The external customer network switch can be shared with other applications. l If the customer network environment is segregated using backup virtual local area networks (VLANs), corresponding VLANs must be configured on the Avamar server. The customer network administrator must provide a list of VLAN IDs to be used by EMC personnel when running the dpnnetutil utility. l For networks that do not require advanced configuration like VLAN and network address translation (NAT) support, the network configuration included in the standard software installation is used. The exception is eth0, which must be configured in advance of software installation. Networking 26 EMC Avamar Data Store Gen4S Customer Installation Guide

As noted in this list of basic network configurations, Avamar systems support the use

of VLANs and separately support the use of NAT. However, Avamar does not support the use of NAT on VLANs. l If all backup, replication, and management interfaces are used, ensure that they are configured for different subnets. l All network ports autonegotiate to 1 Gb Ethernet (full duplex) on the external customer network. l Connections to the customer network are standard leaf connections directly with the single-node server. See the following sections for further clarification of possible ADS networking configurations. Supported network configurations The following sections describe networking scenarios supported by ADS Gen4S servers. l Single uplink to an external customer network l Dual uplink to an external customer network l Dual uplink plus options to an external customer network Single-node servers Single uplink to external customer network The following figure illustrates a single uplink from the server to the customer network switch. Figure 4 Single Uplink Dual uplink to external customer network For high-availability configurations, the following figure illustrates dual uplinks from the server to the customer network. Networking Supported network configurations 27

Figure 5 Dual Uplink

The high-availability external network provides an Avamar server that continues operating through any single network component failure, including: l Any ADS network interface on the external network l Any single uplink cable from the ADS to the customer network l Any port on the customer network used in the uplink l An entire customer switch used in the uplink l Connectivity between customer switches used in the uplink Dual uplink plus options to external customer network For high-availability configurations plus replication and management traffic options, the following figure illustrates: l Dual uplinks from the server to the customer network for high-availability backups, and l Single or dual connections to the customer network for outgoing replication or administration traffic. Networking 28 EMC Avamar Data Store Gen4S Customer Installation Guide

Figure 6 Dual Uplink plus Options

This high-availability external network provides an Avamar server that continues operating through any single failure in a default or optional network component, including: l Any ADS network interface on the external network l Any single uplink cable from the ADS to the customer network l Any port on the customer network used in the uplink l An entire customer switch used in the uplink l Connectivity between customer switches used in the uplink Advanced network configuration – dpnnetutil utility For ordinary implementations, the normal software installation process provides all functionality that is required to configure networking on ADS systems. For more advanced configurations, the interactive dpnnetutil utility must be run before software installation. Advanced configuration scenarios include: l Support for VLAN interfaces to backup networks l Setting custom hostnames l Configuring Network Address Translation (NAT) Note Only EMC personnel can run the dpnnetutil utility. If the customer site requires advanced network configuration, alert the EMC Account Team that the implementation specialist must run dpnnetutil before installing the Avamar software. While dpnnetutil is running, the customer may be asked to check certain hardware-related connectivity errors that the utility might report. Networking Advanced network configuration – dpnnetutil utility 29

Features provided by dpnnetutil

Running dpnnetutil provides the following features: Single-node Gen4S systems For single-node systems, the feature set includes: l Detection of cabling and connectivity errors during configuration, including: n No link detected on a network interface n Link speed below 1GB n Auto negotiation n Full duplex When an error is detected, a dialog box is displayed that describes the error and the network interfaces affected. l Determination of the cabling schema based on the number of physical network interfaces and link presence. l Configuration of the backup, replication, and management networks, including: n Requesting IP addresses and netmask for replication and management networks n Allowing edit and confirmation later Note Remember, if all backup, replication, and management interfaces are configured for use on the single node server, they must be configured for different subnets. l Configuration of backup VLAN interfaces, including: n Requesting a list of VLAN IDs available on the customer network switch n Requesting corresponding parameters for each VLAN ID (IP, netmask) The customer network administrator must provide a list of correct VLAN IDs (typically in the range 1 to 4094). The site networking topology must be such that all clients are able to resolve the Avamar server by the same hostname from different VLANs. Otherwise, backup failures may occur. The dpnnetutil utility populates probe.xml with information obtained during the configuration procedure. Replication The following sections describe the types of replication architectures supported by ADS systems. For complete instructions on setting up and performing replication, including terms and concepts, capabilities and limitations, and best practices, see the EMC Avamar Administration Guide. Single-node servers The networking architecture of ADS Gen4S and the Avamar software provide two types of replication: Basic and Dedicated. They are described in the following sections. Basic replication The source and target systems each have a single network for traffic of all purposes. Replication is in and out on this single network between the source and target pair. The Networking 30 EMC Avamar Data Store Gen4S Customer Installation Guide

target system can be either a multi-node or single-node Avamar server. The following

image shows a multi-node server as the target. Figure 7 Basic Replication Network To configure basic replication, the Avamar software must be installed. The EMC Avamar Administration Guide provides more information about configuring basic replication. Dedicated replication A system that is configured for dedicated replication has dedicated networks on both source and target systems. On the source system, dedicated backup, replication, and management ports can be configured. The following image shows a multi-node server as the target. Figure 8 Dedicated Replication Network To configure dedicated replication, the Avamar software must be installed. An EMC implementation specialist must manually perform additional steps. Networking Single-node servers 31

This chapter describes the prerequisites for installing an Avamar single-node server.

Topics in this chapter include: l Important notices..................................................................................................34 l Prerequisites.........................................................................................................34 Installation Prerequisites 33

The previous chapters provide reference materials. The actual installation process begins

with the following instructions. NOTICE If, during any part of these installation instructions, you encounter hardware or software failure, contact your EMC Account Team for assistance in obtaining the proper services. Installation is not covered under warranty or maintenance contract. NOTICE Modifying the Avamar system in any way other than as instructed by product documentation or authorized EMC personnel is strictly forbidden. This includes installing third-party software on the node; creating, modifying or deleting any file or directory in an Avamar system; or changing any configuration settings in the hardware, firmware, or operating system. Prerequisites A single-node server combines on a single node all the features and functions of the utility and storage nodes of a multi-node server. This includes hosting basic control and communication services (for example, administrator server, NTP, and so forth), as well as storing the actual client backups. Regardless of configuration, all nodes are already burned in and preloaded with the operating system. WARNING The node is heavy and should be installed into or removed from a rack by two people. To avoid personal injury or damage to the equipment, do not try to lift, remove, or install the node without a mechanical lift or help from another person. Site and environmental requirements The EMC Avamar Data Store Gen4, Gen4S, and Gen4T Site Prep Technical Specifications provide component part numbers and a complete understanding of on-site hardware requirements that must be fulfilled before installation of an ADS system (rack space, power, cooling, and so forth). Required tools, equipment, software, and information Before starting, obtain the following: Table 9 Required Items Requirement Description Tools l Phillips-head screwdriver l Tie wraps l Flashlight Installation Prerequisites 34 EMC Avamar Data Store Gen4S Customer Installation Guide

Table 9 Required Items (continued)

Requirement Description l Mechanical lift or another person to assist you with lifting l Material for labeling cords and cables l Paper clip or other similar object Applications l PuTTY l WinSCP Networking information l Hostnames and IP addresses for: n The Avamar server to be installed n One or more Network Time Protocol (NTP) servers n One or more Domain Name System (DNS) servers n SMTP server l Gateway, netmask, and domain for the Avamar server to be installed l IP address for the RMM4 port l Firewall openings (if appropriate) Files Avamar software for use by EMC personnel: l AvamarBundle_SLES11_64- VERSION.zip, which includes: n avinstaller-bootstrap- VERSION.sles11_64.x86_64.ru n n dpnnetutil-VERSION.run n AvamarDownloaderService- windows-x86_VERSION.msi (32- bit version) n AvamarDownloaderService- windows-x86_64-VERSION.msi (64-bit version) n ADS_Gen4_switch_config_01- VERSION.zip n ADS_network_test_SLES- VERSION.run l AvamarBundle_SLES11_64- VERSION.md5sum l The latest version of this installation guide Licensing data l Customer number (Customer ID) Installation Prerequisites Required tools, equipment, software, and information 35

Table 9 Required Items (continued)

Requirement Description l Reference ID (Asset reference ID) Cabling l Cat6 Ethernet cable Verifying checksums After copying the required files to your computer, perform the following: Procedure 1. Verify the checksums and ensure that corruption did not occur during copying. If the checksum does not match, recopy the file to the computer. Note For more information about how to verify checksums using Windows 7, refer to Microsoft KB841290. 2. Extract the files inside AvamarBundle_SLES11_64-VERSION.zip on your computer. Installation Prerequisites 36 EMC Avamar Data Store Gen4S Customer Installation Guide

Mounting the Single-Node Server

The primary purpose of this chapter is to describe how to mount a single-node server in an EMC Titan rack. It can also be used as a general guide for mounting a single-node server in a different environment that uses similar standard racks. Topics in this chapter include: l How to begin.........................................................................................................38 l Rail assembly kit...................................................................................................38 l Hardware Installation............................................................................................38 Mounting the Single-Node Server 37

How to begin

Begin installation by unpacking components and identifying the parts inside. WARNING The node is heavy and should be installed into or removed from a rack by two people. To avoid personal injury or damage to the equipment, do not try to lift, remove, or install the node without a mechanical lift or help from another person. Rail assembly kit The following rail assembly kit is used in all installations: l All nodes: EMC part number 100-564-117 Telco installation is not supported for Gen4S systems. Figure 9 PN 100-564-117 (Left: Assembled, Right: Inner and Outer Rails Separated) Hardware Installation Use the following installation procedure to either mount an Avamar Data Store Gen4S single node server in an EMC Titan rack or in a similar, standard rack in your environment. In the latter case, you should take the following instructions as a general guideline that might require adjustment depending on your environment. Procedure 1. Remove the inner rails from the rail assemblies. See Rail assembly kit on page 38 for additional detailed information. a. On each rail assembly, slide the inner rail out from the slide rail as far as possible. See next image. Mounting the Single-Node Server 38 EMC Avamar Data Store Gen4S Customer Installation Guide

Figure 10 Rail Release

b. On the inner rail, slide the blue disconnect tab forward to release the inner rail from the slide rail. See next image. Figure 11 Disconnect Tab c. Slide the inner rail completely out of the slide rail. See next image. Figure 12 Remove Inner Rail 2. Attach an inner rail to each side of the chassis. a. Align the large end of the rail notches on the inner rail with the connection studs on the side of the chassis. See next image. Figure 13 Attach Inner Rails Mounting the Single-Node Server Hardware Installation 39

b. Push the flat side of the inner rail onto connection studs. See next image.

Figure 14 Connection Studs c. Slide the inner rail backwards along the chassis until the studs fit securely into the small end of the rail notches. An audible click indicates that the rail is secure. See next images (chassis front is at left in both images). Figure 15 Securing Rail 3. Install each slide rail (outside portion of the rail assembly) in the cabinet. a. From the front of the cabinet, align rail alignment posts with the rear channel holes for the bottom 1U (1.75 in) of cabinet space for the node, and insert the alignment posts securely into the holes. See next image. An audible click indicates that the connection is secure. Figure 16 Attach Outer Rail b. Pull the slide rail forward so the front alignment posts go securely into the holes on the front channel. An audible click indicates that the connection is secure. Mounting the Single-Node Server 40 EMC Avamar Data Store Gen4S Customer Installation Guide

c. Secure the rail to the rear channel with a small stablizer screw.

d. Pull the front alignment pins into position in the cabinet's front channel. An audible click indicates the rail is firmly attached to the channel. See previous image. 4. Install the node in the rack. WARNING The enclosure is heavy and should be installed into or removed from a rack by two people. To avoid personal injury or damage to the equipment, do not attempt to lift and install the enclosure into a rack without a mechanical lift or help from another person. When installing the node in the cabinet, do not pick the node up by its power/control module and do not push on its power/control module. This module is on the right side of the front of the node. a. From the front of the cabinet, align the inner rails attached to the chassis with the channels on the inside of the slide rails. b. Slide the chassis into the slide rails and push the chassis into the cabinet. An audible click indicates that the slide rails are engaged and locked. c. On the outside of each rail assembly, slide the blue disconnect tab forward to unlock the node, and push the chassis completely into the cabinet. See next image. Figure 17 Push Chassis Until Click in Place d. To further secure the rail assembly and chassis in the cabinet, insert and tighten a small stabilizer screw directly behind each bezel latch. See next image. Mounting the Single-Node Server Hardware Installation 41

Figure 18 Secure Chassis

5. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch brackets until it snaps into place. See the next image. Figure 19 Front Bezel 6. Connect both power cables to the server and power source. 7. Connect Ethernet cabling when directed in the installation instructions in System Preparation on page 43 Mounting the Single-Node Server 42 EMC Avamar Data Store Gen4S Customer Installation Guide

This chapter prepares the single-node server for Avamar software installation.

Topics in this chapter include: l Preparing the server for software installation.........................................................44 System Preparation 43

Preparing the server for software installation

Perform the following to prepare for Avamar software installation. These steps include configuring the primary backup network port and copying bootstrap utility files. Before you begin CAUTION Do not connect any external network cables to a customer network switch at this time. Connecting external network cables could interfere with the function of the customer's production network and with Avamar software installation. NOTICE Do not try to run either file. EMC personnel will use these files later during Avamar software installation. Note Do not power on cold ADS equipment. The approved operating temperature range is 50° to 95°F (10° to 35°C), and the typical temperature gradation is 10°C per hour. If the ADS components have been located in a colder environment, allow time for the equipment to reach room temperature. For Gen4S systems, the default primary backup network port is (eth0, Gb1). Procedure 1. Configure the network switch or switches to which you plan to connect the single- node Avamar server for a flat layer-2 configuration. Seek the advice of your network administrator to do this. 2. Connect power to the Avamar server and press the power button on the front of the node. 3. Connect the laptop as follows: a. From Start, open Control Panel. b. Note In Windows 7, the Control Panel can be configured for one of three views using the View By drop-down: Category, Large Icons, and Small Icons. The latter two are functionally identical. For Category view, click Network and Internet > Network and Sharing Center. For Icon view, click Network and Sharing Center. c. In the left pane, click Change Adapter Settings. d. Right-click Local Area Connection and select Properties. e. Double-click Internet Protocol Version 4 (TCP/IPv4). f. Select Use the following IP address. g. Set the IP address to 10.99.99.99. h. Set the Subnet mask to 255.255.255.0. System Preparation 44 EMC Avamar Data Store Gen4S Customer Installation Guide

Set the Default gateway to 10.99.99.5.

j. Click OK to close the Internet Protocol Version 4 (TCP/IPv4) Properties sheet. k. Click OK to close the Local Area Connection Properties sheet. l. Using an Ethernet Cat6 cable, connect the laptop to the eth7 network interface (NIC8 port). m. At a Windows command prompt, type ipconfig to ensure that the new IP address is active. If not, right-click Local Area Connection and disable it, then re-enable it. 4. Using PuTTY, open a connection to the Avamar service port (10.99.99.5). 5. Log in as the root user. 6. Open the YaST Linux configuration application by typing: yast The YaST Control Center appears. Figure 20 YaST Control Center Note In YaST, use the Tab key to move to an option. Correct typing errors or replace default settings by using the Backspace key. To select a checkbox (a set of parentheses), press the spacebar. 7. Use the down-arrow to highlight Network Devices, the right arrow to move to the box on the right, and the down-arrow to highlight Network Settings, and then press Enter. The Network Settings screen appears. System Preparation Preparing the server for software installation 45

Figure 21 YaST Network Settings - Overview

8. Tab to the Name list and use the arrow keys to select the primary backup network port, noted at the beginning of this task. As you move from one entry to the next in the list, the description in the second box changes. You may need to tab to the second box and use the arrow keys to scroll until you can see the interface name assigned to each network card. 9. With the primary backup network port selected, tab to Edit and press Enter. The Network Card Setup screen appears. Figure 22 YaST Network Card Setup 10. Use the arrow keys to select the Address tab, if required. 11. Tab to Statically assigned IP address. System Preparation 46 EMC Avamar Data Store Gen4S Customer Installation Guide

12. Select the checkbox (with an X) by pressing the spacebar.

13. Tab to IP address. 14. Type the IP address assigned to the primary backup network port. 15. Tab to Subnet Mask. 16. Type the subnet mask address assigned to the primary backup network port. 17. Tab to Hostname. 18. Delete the default hostname. 19. Type the hostname assigned to the single-node server. The hostname must resolve to the IPv4 address used by backup clients and the address to be assigned to the primary backup network port in the followup Avamar server software installation. 20. Tab to Next at the bottom of the screen and press Enter. The Network Settings screen appears. 21. Tab to the top menu and use the arrow keys to select Hostname/DNS. Figure 23 YaST Network Settings - Hostname/DNS 22. Tab to Hostname. 23. Delete the default hostname. 24. Type the correct hostname. This parameter must be the short name of the hostname that you typed on the previous screen. 25. Tab to Domain Name. 26. Delete the default domain name. 27. Type the correct domain name. 28. Tab to the DNS configuration section and specify these parameters. Type up to three IPv4 addresses of DNS recurring name resolving servers. System Preparation Preparing the server for software installation 47

29. Tab to Domain Search.

30. Use the right arrow to move the cursor to the end of the default entry and delete the default domain name. 31. Type the correct domain name to be searched. 32. Tab to the top menu and use the right arrow to select Routing. The Network Settings-Routing screen appears and Default Gateway should be highlighted. Figure 24 YaST Network Settings - Routing 33. Type the default gateway address. 34. Tab to OK at the lower right of the screen and press Enter. The Network Settings screen closes and a saving configuration information message is displayed. 35. In the YaST Control Center, tab to Quit at the lower right of the screen and press Enter. 36. Connect cabling from the primary backup network port to the customer network switch, and replication and management network cabling, if used. NOTICE Do not connect cabling for high-availability ports at this time. Doing so can cause serious disruptions to the customer network. 37. Use WinSCP to copy the following files from your computer to the /usr/local/ avamar/src/ directory: l AvamarBundle_SLES11_64-.zip l AvamarBundle_SLES11_64-.zip.md5sum where is the version of the Avamar software to be installed. 38. Disconnect the Ethernet cable from the eth7 (NIC8) port. System Preparation 48 EMC Avamar Data Store Gen4S Customer Installation Guide

39. Close the terminal window.

40. Verify connectivity to the primary backup network port from the customer network by establishing a PuTTY session. Results This concludes customer installation activities for the ADS single-node server. System Preparation Preparing the server for software installation 49