uvádí www.emareg.cz [email protected] Pro technickou pomoc a dotazy nás kontaktujte +420/ 777884900 [email protected] Registrátor teploty s tiskárnou, bezdrátový pøenos mezi èidly a kabinou

food  products. Thanks  to  it,  food  companies  and  carriers  can  monitor,  archive  and  document  the

temperature at every stage of the food supply and storage chain. The device meets the requirements of the European Union Directive 92/1/EWG and the European Commission Regulation no. 37/2005. The recorder also meets the standards PN­EN 12830:2002 and PN­EN 13485:2002. The set includes a manufacturer calibration certificate. A calibration certificate in accordance with EN ISO/IEC 17025 is available at an additional cost. The recorder is made in a small, ergonomic housing with a modern graphical display and a built­in thermal printer. It is powered by a built­in battery that allows you to work without a charger for 48 hours. Thanks to these features and wireless communication with measurement sensors, the device is fully mobile and comfortable in everyday use. The set includes a car holder for mounting the device in the driver's cabin and a car charger. The recorder has 4 temperature measurement channels and 4 signaling channels for door opening by the 1400mAh (removable) battery with power  supply  from  vehicle  installation  12...24V  DC ±10%(battery life minimum one year). Each wireless sensor has a built­in temperature probe and the ability  to  connect  the  door  open  sensor.  For  each  wireless  sensor,  you  can  also  connect  a  one additional temperature probe via a 10mb cable sensor (Cable sensor DR203).  As a result, the wireless sensor can, for example, be mounted directly in the refrigeration chamber and measure the ambient temperature and, in addition, the second temperature can be measured by a cable probe inserted into the refrigerator compartment or another fridge. After  connecting  the  door  limit sensor,  each  chamber  door  open  and close  operate  can  be  signaled  and  recorded.  Sensors  are designed  to  work  in  hard  environmental conditions  (low  temperatures,  high  humidity)  with  IP­65 protection. Cable probes with stainless steel measuring tips allow direct food contact. DR­203 is designed to monitor and record temperature. Built­in non­volatile memory allows you to record 125,000 measurements points (memory: 3 years at the memorization frequency of 15 minutes). The interval for saving data to the memory can be set in the range from 1 min to 24 hours. When the memory is full, the recorder works in a loop, the oldest samples are overwritten by new measurements points. The recorder can work in one of two modes: ­ continuous registration ­ registration of deliveries (only during the course) In the first mode, the device records the measurements all the time and can save data even after switching off the recorder (if the  Auto­OFF parameter set = NO) or loss of communication with radio sensors. It is possible thanks to the sensor's cache memory (1000 measurements points), which saves the data to it's own memory and sends it after regaining communication with the recorder. In the second case, the registration data process is switched on and off with the every start and stop button operate, which simultaneously marks the start and end of the course. During  operation,  the  recorder  indicates  the  current  temperature  of  the  sensors,  time  and  alarm thresholds messages. After pressing the info button, you can display the state of the sensors and the ?measured since the device was turned on. The built­in menu allows for a wide configuration of the device: ­ temperature alarm thresholds for each sensor ­ sound signaling of alarms ­ entering the names of sensors and user descriptions in the header and footer of the print report by built in printer ­ choosing a language, setting the date, time and time zone ­ selection of the registration method and it's parameters ­ bluetooth communication settings The parameters menu is divided into two groups: ­ basic for the driver ­ advanced for the service department Access to the service department menu can be password protected. After entering the password, the memory data can be deleted and all parameters settings can be restored to the factory settings. 2

Xxx 125 000 measuring points wireless sensor memory: 1000 measuring points 1400mAh battery removable power supply 12...24V DC ±10% from vehicle installation or attached car charger work without charger up to 48h during registration of 40mA, while printing to 3A 4 temperature channels 4 signal door channels (normally closed or open) ±0,3 : ­20...+50 ±0,5 °C in the range °C: , in the remaining °C 1min...24hours thermal, printing speed 80 mm/s, thermal paper with a roll width of 57 mm, a roll with a diameter of 35 mm graphic OLED with backlight IP­30, housing for assembly in the driver's cabin, ­20...50°C ­50,0...+99,9°C printout of current reports printout of delivery reports printout of historical reports continuous registration or courses copying data to portable USB media cooperation with a smartphone (Bluetooth) sending data to the server SMS notification PDF reports by e­mail GPS location automatic change of summer time, time zones temperature and door opening alarms sound signaling editing user data on the printout password to access the service menu restoring factory settings, deleting data   3 years, non­volatile memory Menu and print language: Polish, English, German, French, Italian, Spanish, Czech, Slovak, Croatian, Romanian, Russian, Ukrainian EU Directives: 2014/30/EC ; 2014/35/EC; 2014/53/EU; 92/1/EU Norms: EN­61326­1:2013; EN­61326­2­1:2013; EN­61010­1:2010; EN­301489­1 V1.9.2:2011; EN­12830:1999; EN 13486:2002 USB 2.0 micro type B, optional: Bluetooth 4.0 class 2 wireless radio communication 868MHz range up to 100m in open space (standard antenna) range up to 200m in open space (additional optional antenna) IP­65, hermetic housing ­50...99.9°C 3.6V LS14500 battery 2600mAh size AA (R6) or A (R23) replacement battery lifetime min. 1 year Xxx 3

­  wireless  sensor  with  built­in  temperature  probe  and  the  possibility  of  connecting  a  second

temperature probe on the cable and a door opening sensor ­ instruction manual /warranty card ­ thermal paper roll (width 57 mm, diameter 30 mm) ­ universal car charger for 12V/24V cigarette lighter ­ car holder for mounting the recorder in the cabin Please read the instruction manual carefully before installation. Any damage caused by not following these instructions causes the warranty/guarantee to be lost! In the event of any material losses, the manufacturer bears no responsibility! In the case of damage to property caused by improper use of the device, the manufacturer bears no responsibility! Dear customer, the following safety rules apply to health protection describe the correct use of the product and instructions for use. ® For safety reasons, rebuilding or modification of the product isn¶t allowed ® Repairs may only be carried out by the manufacturer or specialized workshops ® The recorder and charger can be operated only in dry interiors. The devices can not be dampened or wet. Otherwise there is a risk of failure ® Don¶t use the charger unattended. Despite the built­in safety system, problems can not be ruled out when charging the battery ® When the device isn¶t used for a long time, remove the battery from the recorder and disconnect the charger from the power source. Then store the battery and charger in a clean and dry place. Please remember that the car charger draws energy even when there is no device connected to it. When not in use, disconnect it to avoid discharging the battery ® A lithium­ion battery was used to power the recorder. The battery can not be dampened or wet. Protect the battery from heat and direct sunlight. Do not short circuit the battery electrically or throw it in a fire. There is a danger of explosion and fire! ® Charge the batteries at least once every 3 months. Otherwise, the battery life will be shortened ® The 3.6V lithium­thylium battery was used to power the sensor. Do not short circuit the battery electrically or throw it in a fire. There is a danger of explosion and fire! ® Always insert the battery in accordance with the polarity (plus/+ and minus/­) given on the battery and sensor board ® The recorder is maintenance­free, never dismantle it yourself (except when inserting/removing the battery during storage) ® Use soft, clean and dry material for cleaning ® Data security: before any changes to the configuration of parameters in the service menu, you must back up the data to an external portable data memory. The manufacturer isn¶t responsible for data loss, caused by incorrect settings or improper use. The producer also doesn¶t accept claims regarding data loss or consequential damages of the device ® The recorder should work in conditions of ambient temperature in the range from ­20°C to 50°C and relative humidity in the range from 10% to 90% ® The holder with the recorder can be mounted on the windshield only when it does not cover the driver's view. When mounting the holder, choose a place so that the handle does not pose a threat also during a road incident ® Don't mount the recorder within the range of work of the airbags. 4

The  built­in  USB  port  allows  you  to  download  data  from  the  recorder's  memory  to  a  pendrive.  In

addition,  the  recorder  can  be  equipped  with  a  Bluetooth  interface  for  communication  with  mobile devices.  Free  application  for  mobile  devices,  allows  for  easy  operation  of  the  device  from  the smartphone  screen.  The  application  allows  you  to  monitor  temperature,  signal  alarms,  implement courses, send SMS notifications and send PDF reports to e­mail. It also gives the possibility of sending information about the GPS location and measurement data to a remote server, called "cloud´ www.escomonitor.com Thanks to this, through the web browser, it is possible to monitor and manage the fleet of vehicles. Cloud  allows you to view the temperature, location of vehicles and their routes, temperature alarm thresholds  and  automatic  generation  of  PDF  reports  by  e­mail  and  sending  SMS  notifications. Example of installation and arrangement of measuring sensors: 5

The  recorder  has  been  designed  for  use  in  the

driver's  cab.  The  kit  includes  a  car  holder  for mounting  on  the  front  or  side  window  of  the  car. When mounting the bracket, select the appropriate mounting location, following the instructions below: Dispose  of  the  product  at  the  end  of  its  operation  in  accordance  with  applicable  legal regulations. In accordance with European Directive 2002/96/WE and the Act on Waste Electrical and Electronic Equipment, this label indicates the ban on the placement of used electronic equipment together with other household waste. Return the worn device to the appropriate storage point, or send it to us, because dangerous components in the device may be a threat to the environment. Batteries  and  accumulators  containing  harmful  substances.  Used  batteries  and accumulators can be taken away free of charge to the appropriate storage point, to us or wherever batteries and accumulators are sold. Thanks  to  this,  you  meet  legal  requirements  and  contribute  to  the  protection  of  the environment! ASSEMBLY: Press the suction cup (A) in the designated area, to the front or side window of the car, making sure that the suction cup and glass are clean, without any traces of water or other contaminants. Then move the locking lever (B) towards the glass. After mounting the bracket on the glass, unlock the lower support (C) and place the recorder between the two jaws (D) of the bracket. Then snap the DR­203 with the jaws so that it is rigidly placed and that it does not slide out while driving. Use the two knobs to adjust the viewing angle, position and direction of the recorder display. ­ do not cover the driver's field of vision ­ do not mount the set within the range of the operation of the airbags ­ do not attach the set too close or opposite the head so that it doesn't pose a threat during a road incident C B D D E A Turn the knobs so that the handle doesn't unlock and doesn't move while driving. After some time of use, re­tighten the knobs and tighten the clamping jaws and make sure that the recorder is properly mounted. At any time, the recorder can be removed from the holder by releasing the (E) unlocking button. 6

  symbol  in  the  display  does  not  flash.The  first

charging of the battery recorder should last for a minimum of 3 hours. The battery symbol informs about the state of charge of the recorder. The device should not be completely discharged and the battery life may be reduced. It is forbidden to connect chargers, phones and other mobile devices to the micro USB socket on the left side of the DR­203 recorder! This socket is intended only for transferring data to a USB flash drive (pendrive) BATTERY When the device is not used for a long time, remove  the  battery  from  the  recorder  and disconnect the charger from the power source. To remove the battery, turn the recorder to the other side. Press the latch in the middle of the case and remove the battery from the device. Keep the battery and charger in a clean and dry place. Read the safety rules for battery and car charger in point 5.1 7

CONSTRUCTION: BATTERY REPLACEMENT (if the red LED flashes every 60 sec.): B A C D E F CONNECTION: Notes for D1: ­ polarity of wires does not matter ­ female connectors 2.8 x 0.8 mm ­ use a two­core cable with a cross­section of min. 0,5 mm2 and length up to 30m Notes for T2: ­ polarity is important ­ sensor cable with a length of 10mb extension allowed up to 20mb using a cable with screen and 26AWG section A  built­in temperature sensor B  additional temperature probe on a cable with a length of 10m C  radio antenna D 1 hermetic housing with room for battery and wire connectors E  signaling diodes on the board: unscrew 4 screws and remove the housing cover COM (green): radio communication BAT(red): low battery SIGNALING OF DIODES: ­ every 60 sec. blinks once (communication OK) ­ every 60 sec. blinks twice (communication lost) ­ blinks once at startup after inserting the battery ­ every 60 sec. blinks once (low battery voltage) ­ blinks once at startup after inserting the battery DESCRIPTION: ted  Each wireless sensor has a built­in temperature probe. Additionally, it has the possibility of connecting the door opening signaling sensor and the second temperature probe on The recorder has 4 temperature measurement channels and 4 signaling channels for door opening operation. Temperature sensors are connec  to the recorder wirelessly. 2  mount a new battery in the holder, paying attention to the correct one polarity (the negative pole is on the side of the antenna) 3  screw in again, solidly 4 screws on the housing cover F  mounting brackets 8

connected  on  the  cable),  number  and  location  of  temperature  measurement  points  and  logic

signals from the door. This is a very important aspect regarding reliable temperature monitoring during transport and food storage.  According  to  the  guidelines  of  GDP  (Good  Distribution Practice) and the HACCP system, it is necessary to identify the threats of too high or low temperatures that may break the so­called cold chain and locate critical control points, their necessary number and critical conditions that will allow later setting of alarm thresholds in the recorder menu. The location of the measurement sensors should be preceded by the mapping of the cooling chamber with the determination of the temperature distribution, checking the effectiveness of the cold store and the final assessment of the risk analysis, which will allow the optimal selection of their location and number. The following assembly notes should be taken into consideration when analyzing and making decisions: sensors are adapted to work in hard environment conditions (low temperatures, high humidity) with IP­65 enclosure protection to keep the housing tight, it is forbidden to make additional mounting holes. It is also important to firmly tighten the housing cover, and the cables of additional sensors, lead out of the housing through a cable gland measuring tips of additional cable probes are made of stainless steel and allow direct contact with food the standard range of wireless sensors in open terrain is 100m. When installing the sensor inside  an  insulated  cold  room  with  walls  and  partitions  made  of  metal,  which  constitute  a screen, for a radio signal, the propagation of radio waves is very limited and the distance for proper communication between the recorder and the sensors decreases. This is not a problem when used in delivery trucks and trucks with integrated refrigeration. However, when used in vehicles with a trailer or trailer, an optional long­range antenna must be used sensors  should  be  installed  in  ventilated  areas,  not  exposed  to  mechanical  damage when loading or unloading goods sensors should be installed min. 50 cm from the cold room lighting sources it is recommended to install min. 1 temperature sensor for each refrigeration chamber, in the upper part of the room, in place of 2/3 of the evaporator chamber length and additionally a temperature sensor (optional cable probe) on the return of air attach the wireless sensor to the wall in the holes of the mounting brackets using two screws or screws with a diameter of 3mm for mobile cold rooms, refrigerators and other places exposed to additional mechanical damage, it is recommended to use temperature probes on the cable the cable probe should be connected to the T2 connector in the wireless sensor according to color markings given in the description "CONNECTION" in point 5.4 the cable probe is a 10m cable. It is allowed to extend the cable to 20mb using a three­core cable with a screen with a minimum 26AWG (0.14 mm2). The wires and the screen should be ® ® ® ® ® ® ® ® ® ® ® 9

®  to signal the opening of the chamber door, connect to the input D1 of the wireless sensor, a two­ core cable with a thickness of min. 0.5mm2, the limit sensor should be installed in the door. When the door is opened, the limit switch contacts close or open and sends the status change signal to the recorder. The door alarm configuration is available in the service menu. The door limit switch is available as an accessory. The sensor cables do not require polarity of the wires The signaling of door opening is to consist only in shorting or opening the digital input circuit D1, not on transferring voltage! When using this input for signaling aggregate operation or defrost cycles, special care should be taken to ensure that no signaling circuit is energized Display 3 1 1 2 4 5 printer compartment with space for thermal paper 2 micro USB port for data transfer 3 power socket 4 Service socket (not used) 5 The kit includes a roll of thermal paper that must be installed in the printer. Thermal paper used for printing is standard and available at points of sale with paper products. It is recommended to use rollers with a width of 57 mm and a diameter of 35 mm. Paper installation method: 1. open the printer cover (grab in places marked with arrows) place a roll of paper in the printer compartment (right part of the thermal paper) and pull it out about 3 cm of paper over  serrated printer's knife close the printer door by controlling to make paper he left the printer correctly tear off the protruding end of the paper using the casing mounted on it serrated cutting knife 2. 3. 4. Thermal paper is "single­sided" and must be correctly installed in the printer. If, after starting printing, the printout is invisible, install the paper so that it unwinds from the other side. 10

Info button (UP and more) 1 delivery button (DOWN and decreasing) press 3 sec. to disable/enable registration (only in the "Delivery" registration mode) 2 menu button (LEFT and cancel) press 3 sec. to turn on/off recorder 3 2 4 1 3 6 12 11 10 9 8 7 5 13 print button (RIGHT and accept) 4 the temperature measurement value 5 the temperature sensor number 6 battery voltage level indicator flashing: the charger is not connected lights up: charger connected 7 temperature registration started 12 11 10 13 8  Bluetooth communication indicator blinking: waiting for connection lights up: connected Symbol       indicates which door are open temperature exceeding alarm 9 delivery of goods (the course is on) current time temperature unit After completing the recorder installation, the device must be configured. The parameters menu is divided into two groups: ­ basic menu for the driver ­ advanced menu for the serviceman press to cancel the changes and to exit one level up in the menu. While text editing press to move to the editing of previous character. To start menu configuration press "menu" button. Next using the keyboard buttons, configure the device following the instructions below: Press to change the parameter values and to switch between the parameters in the menu. Press to start editing parameter or to confirm changes, while text editing move to editing next character The basic menu is intended for the driver who will use the device daily. It contains basic settings necessary for convienient use. This menu is not protected by a password. 11

the  change  of  back  time  is  blocked  to  prevent

overwriting and loss of data. First, archive the data via USB or Bluetooth, and then delete the memory in the service menu of the recorder. Then you will be able to set a time earlier than the current one. When the recorder has stored data in the memory, the  change  of  back  date  is  blocked  to  prevent overwriting and loss of data. First, archive the data via USB or Bluetooth, and then delete the memory in the service menu of the recorder. Then you will be able to set a date earlier than the current one. Temperature and door­opening alarms sound signalisation Access  to  the  service  menu  can  be  protected  by  a password.To enter to the service menu you have to give a correct password and press µOK.¶button. When password is set to 0000 access to the service menu is unprotected. 12

Addition/removal and configuration of sensors (see section 10.5) Operation mode of the recorder. Recording interval(frequency of data saving). Setting range: 00:01...23:59 min:hour. Constant: Delivery: ­ records data continuously ­ recording is signalled with icon ­ recording the time of load/unload by pressing button ­ after the load start, drive is signalled with icon ­ If you want the sensors to save data themselves after turning off the recorder: see section "Auto­OFF" There are two operation modes: ­ records data only during the delivery ­ delivery and recording process starts/ends manually by pressing button for 3 seconds ­ delivery and data recording signalled with icons        and Auto­OFF=YES ­ after turning off the recorder, the sensors go into sleep mode and they do not save the data. Auto­OFF=NO ­ after turning off the recorder, the sensors are still saving data in their cache memory. Sensor¶s cache memory can hold 1000 measurements. When cache memory is full, sensor overwrites the oldest data with the newest measurements. After turning on the recorder and restoring the communication, the sensors send overdue data to the recorder. In both operation modes data is saved in a memory with a capacity of 125,000 measurements. If memory is full recorder overwrites the oldest measurements. Sensors have their own memory with a capacity of 1000 measurements. If they lose radio communication with a recorder they save data in their own cache memory (in a loop). After the connection is restored they send overdue data to the recorder. 13

Automatic change of time from winter to summer and vice versa. Set the UTC time zone for your area (see map). Headline ­ text on the begining of each printout in which user can place information, e.g company name and adress, vehicle registration number. Maximum 4 lines of text, 19 characters each line. Depending on the chosen language, you can use entire alphabet. Starting with lowercase letters, then capital letters, numbers and finally special characters. Use  button to chose a character. Press  to move to next character edition. Press  to back to edition of previous character. When you finish press  for 3 seconds to save data. Footer ­ text at the bottom of each printout, under the place for a signature, in which you can place additional user information, e.g Driver¶s first and last name, advertising slogan or carrier¶s website adress. Maximum 4 lines of text, 19 characters each line. Depending on the chosen language, you can use entire alphabet. Starting with lowercase letters, then capital letters, numbers and finally special characters. Use  button to chose a character. Press  to move to next character edition. Press  to back to edition of previous character. When you finish press  for 3 seconds to save data. Bluetooth configuration (parametr is visible only in the devices with Bluetooth module installed). Name of the recorder seen in a network and PIN code necessary to pair with a mobile device. Default PIN code is: 1234. It can be edited by the user. Header text Daylight saving time and time zone setting Footer text 14

To  restore  device  to  the  default  settings  press

,  to cancel press  button. After pressing  a message, as seen on left, will appear. To  restore  device  to  the  default  settings  press ,  to cancel press  button. After  pressing   the  process  of  restoring  will  start. Settings will be restored to default. Data memory, printout counter and time/date settings will be saved. Memory removal. To remove all memory data press  , to cancel press button. After  pressing   a  message,  as  seen  on  left,  will appear. To remove all memory data press to cancel process press  button. After pressing  the process of data removal will start. Data will be lost irrevocably. Data security: before any change to the parameters in the service menu, please make a safety backup of the data on an external data carrier. Producer is not responsible for data loss caused with a incorrect setting in the service menu, improper use of the device and accidential data removal by an unauthorized persons. Does not accept claims regarding data loss or consequential damages. Protecting access to the service menu with an unique password is highly recommended. Service menu access password When password is set to 0000 access to service menu is unlocked and does not require a password to enter to the menu. 15

Run  user¶s  menu  and  go  to  the  service  menu.  If  the

access to the menu is protected ­ enter a password and confirm pressing µOK.¶. ADDING SENSORS: Recorder has 4 measuring channels. It can operate with 4 temperature sensors,no matter they are wireless sensors or additional   cable probes. You can pair the device with 4 independent wireless sensors or or e.g. 2 wireless sensors and 2 additional cable probes.. Before pairing the sensors with the recorder, run the sensors and connect them accordingly to paragraph 5.4 then follow the Sensor will not be visible in radio network, if it ever has been previously paired with another recorder. To pair the sensor with a new device, please remove the battery out of the sensor Go to µSensors¶ section, then µAdd¶ and start searching sensors in the network with a button¶OK¶ Searching lasts around 1 minute and it is signalled by following message: After  completing  the  recorder  will  display  a  list  of  all available sensors. Example on the left. Check the sensor¶s number and choose the one you want to add by pressing . If  it  is  wireless  sensor  with  data  stored  in  the  cache memory, the following message will appear: Confirm  with  µOK¶or  cancel  the  download  of uneccesaryprevious data with µ ¶ button. After adding a sensor the device will go back to the list of sensors. Add another sensor and follow the process as above or exit the add  list using µmenu¶ button. Each  wireless  sensor  has  an  unique identification  adress, which can be found on the label. Cable probe has a number similar to wireless sensor  to  which  it¶s  connected.  (First  three numbers are the same, last one is higher by one value . Address: 15B3 Sensor¶s adress: Measurement Range  Battery Adress If the sensor you would like to add is not on the list please check the battery, diod signalisation, cable probe  connection  or  possibly  reset  the  sensor  by removing  a  battery  for  3  minutes.  Try  to  restart searching. After  adding 4 sensors, following message will appear: Exit sensor adding function with µ button 16

Open  the  user¶s  menu  and  go  to  service  menu.  If  the

access is protected enter the password and confirm with ³OK.´button. SENSOR CONFIGURATING: After completing adding of the sensors you have to configure them. Each sensor can be set with: ­ measurement calibration ­ two temperature alarm levelss (MIN and MAX) ­ name ­ door opening alarm Then go to section µ Sensors¶ take option µEdition¶ and press µOK...¶ List of connected sensors will appear. Chose a sensor to configure and press µOK..¶. All sensor¶s parameters will be displayed. Chose a parameter to configure and press ³OK.¶.  ­ when the value of measured temperature is different than real value you can calibrate the temperature sensor. Parameter value is added to the measured value. ­ Value range: ­10.0...+10.0°C   ­  minimal  temperature  level.  If  the temperature reaches this level, the recorder will activate buzz alarm  and an alarm will be displayed. Alarms will be saved in the memory  and  marked  on  the  printout.  Setting  range:  ­   ­  maximum  temperature   level.  If  the temperature reaches this level, the recorder will activate buzz alarm and an alarm will be displayed. Alarms will be saved in the memory and marked on the printout. Setting range: ­50.0...+99.9°C  ­ user¶s description e.g. Rear sensor, fridge etc. Using µup/down¶ ­ chose a character Using µOK.¶ ­ edit next character. Using µMenu¶ edit previous character Save description by pressing µOK..¶ for 3 seconds   ­wireless  sensor  is  equipped  with  door­ opening sensor. Connect door sensor to logical input D1 with cables as in paragraph 5.4 and chose a circuit type: ­ NO (normally opened) alarm after closing D1 ­NC (normally closed) alarm after opening D1 NO ­ door sensor deactivated 17

Data security: before any change to the parameters in the service menu, please make a safety backup of the data on an external data carrier. Producer is not responsible for data loss caused with a incorrect setting in the service menu, improper use of the device and accidential data removal by an unauthorized persons. Does not accept claims regarding data loss or consequential damages. Protecting access to the service menu with an unique password is highly recommended. DELETE  SENSOR: At the  service menu level you can remove a sensor: Open user¶s menu and go to the service menu. If menu is protected, enter the password and confirm using µOK.¶ Go to section µSensors¶ > Delete> OK. The list of connected sensors will appear. Chose a sensor to delete  using µOK.¶ A message will appear: Confirm using µOK.¶ or cancel deleting using µmenu¶ button. After removing the sensor, you will be moved back to the list. Chose another sensor and follow the above instruction or exit deleting function using µmenu¶ button. Current measurements printout To print current measurements press           . Printing window will apeear (as on the left). Choose option:  and press Recorder will start printing and display a message: Due to built­in thermal printer you can document the process of temperature recording and have an evidence for the receivers or control services. You can print 3 types of printout reports: ­ Present values (current measurements printout) ­ Delivery report ­ Historical report (report from a given time) Data is printed chronologically, from the newest to the oldest measurements. 18

Delivery report. If you are using a µdelivery¶ option (paragraph 12), you can print a last delivery report, without a need of entering a specific date and time. Printing window will apeear (as on the left). Choose option:  and press Recorder will start printing and display a message: Recorder will start printing and display a message: If the delivery is still in progress (      backlited), a report from the moment of load to the moment of printout report will be printed After completing the delivery a report from the load to the unload will be printed. If the message µno data¶ appears, this means there is no data of the delivery in the memory. To cancel the printing press µOK.¶ Historical report In this option recorder is printing data from a given time. Printing window will appear (as on the left) Choose option: µHistorical report¶ and press µOK.¶ If the message µno data¶ appears, this means there is no data of the chosen time in the memory. To cancel the printing press µOK..¶ Measurement data is saved at a fixed interval, and events such as loading / unloading, temperature alarm and door opening are saved as additional cells in memory. Overdue data from sensors, after regaining lost communication, are added to the recorder's memory. Therefore, when printing, it happens that in one minute several events may occur and the sensor error is overwritten with the correct measurement, with the same time, because it was later downloaded from the sensor's cache memory after recovering the Set start date using  buttons and press Set end date using  buttons and press Set end time using  buttons and press Set start time using  buttons and press To print a last delivery report press          . To print a historical report press          . 19

18 Vehicle registration number User¶s data (header) Time of load and unload Connection lost Signature Temperature  alarm Model, version and factory number FIRMA VAN, 05­300 SANOK, MLECZNA 6 T1 = czujnik temperatury front 1 T2 = czujnik temperatury ty³ 2 T3 = zamra¿arka 3 T4 = lodówka 4 D1234 = drzwi otwarte .......................................................................... .......................................................................... Raport z dostawy: DR­203 v.1 Numer fabryczny: 20180511 .......................................................................... www.esco.eu.com R.00023 2018­08­22   23:31 Czas   T1[°C] T2  T3  T4 D1234: [°C] [°C] [°C] ­­­­­­­­­­­­­­­­­­­­­­2018­08­22­­­­­­­­­­­­­­­­­­­­­­ Podpis: ........................................................................ ­­­­­­­­­­­­­­­­­­­­­­Za³adunek­­­­­­­­­­­­­­­­­­­­­­­ 21:59 ­­­­­­­­­­­­­­­­­­­­­­Roz³adunek­­­­­­­­­­­­­­­­­­­­­ 08:00    ­19.3    3.6   13.2   18.0 07:35    ­21.0    0.9   15.9   EE ­­­­­­­­­­­­­­­­­­­­­­­­2018­08­22­­­­­­­­­­­­­­­­­­­ Numer rej.:   WAW 99BB ­21.3    1.9   15.6   16.8 03:35    ­22.4    0.8   14.2   19.1 Names of the sensors Number and date of the printout User¶s data (footer) Door opened ALARM = wskazania alarmu MIN/MAX EE = brak po³¹czenia EXEMPLARY PRINTOUT: 20

In  this  record  mode,  device  after  starting,

automatically records data and constantly save them There is no possibility to turn off the recording during work. Recording is signalled with icon In  this  mode  device  does  not  record  data automatically.  User  himself  start  and  stops   the process of data recording by pressing button start/stop for 3 seconds Recording is signalled with icon Time Data recording ON OFF Time Data recording ON OFF start 3s stop 3s In the continuos mode data are saved constantly and delivery  function  is  additionally  used  to  record  the start and end of delivery  (Load and Unload) in order to later identification of the course in the printout. To register the start of delivery, press button Icon will appear and message will be displayed: To register the end of the delivery, press Icon        will go out and message will be displayed: While recording you can initiate an unlimited number of delivery, thanks to app for the mobile devices you can add additional comments to every load/unload. It allows you to easier identification of dates, type and places In the delivery mode, the start of recording is at the same time the begining of delivery(Load), and the stop  of  recording  is  the  moment  of  the  end  of delivery(unload). To  start  the  delivery  and  start  the  data  recording press µstart¶ button for 3 seconds Icons                and a message will be displayed To end the delivery and data recording press And hold the button for 3 seconds Icons                will go out and a message will appear: Time Delivery Load Load Unload Unload Time Delivery Load Start Start Load Unload Unload 3s 3s 3s 3s Stop Stop Data recording 21

at  10.8°C,  but  it  will  turn  off,  when  the  temperature  rises  to  11.8°C  and  vice  versa  if  the

Alarm MAX=20.2°C, turns on at 20.2°C, but turns off when it drops to 19.2°C Wireless sensor is equipped with logical input to which a limit sensor, for signaling door opening ,can be connected. Connecting method is described (see 5.4), and the settings of the type of door opening circuit(NO / NC) are in the service menu (see 10.4) While opening the door, connectors of limit sensor are opening or closing and they pass a signal of changing the position to the recorder. Recorder will turn on a sound signallisation for a moment Icon with door number will be displayed         (number of the wireless sensor to which the door opening sensor is connected). The event occured will be saved in the recorder¶s memory and marked on the printout. INFO  function  helps  the  user  to  quickly  check  the  status  of  sensors  and  emergency situations. After  pressing the button a window  will be Sensor¶s number Range Battery Minimum Maksimum The information window will be displayed for 5 seconds, after which, if alarm states are active, alarm messages will be displayed. Then recorder will return to normal display mode. To quickly return to normal display mode press the button. The MIN and MAX values are extreme values that have occured since the recorder was turned on. This values are for information purposes only and theyare not saved to the memory. (Do not confuse these values with the temperature threshold described in the paragraph 13). 22

The built­in USB port allows you to save data from the recorder¶s memory to an external USB flash drive. Due to its dimensions, the recorder has a USB micro typ B connector. It is the same connector as the USB micro power connector in most mobile devices on the market. Please buy a memory card with a micro USB type connector, available in general sale, or alternatively a carrier with a standard USB connector Number of the record, date, time and measurements Recorder will display a message: 2 Recorder will start data copying and a message will be displayed: 3 Confirm pressing After completing  a message will appear: 4 Remove a USB flash drive from the recorder and connect to a USB port on your computer Open the disk in Windows Explorer. On the USB disk will be created the main DR­203 folder in which they will be created subfolders with individual ones serial numbers of recorders. In a single subfolder with factory number, TXT files will be saved with data with the date and time of creation. 6 All the data from the recorder¶s memory will be saved in the TXT file. You can open the file with Excel. We recommend to archive the files on a separate drive. Door opened Temperature alarm Unload It is forbidden to connect chargers, phones and other mobile devices to the micro USB socket of the recorder! This jack is intended only for transferring data to a USB stick (pendrive) In order to copy data please plug in a USB flash drive with micro connector to the recorder socket 1 5 7 Factory number 23