IDS 860-06-0005 Manual 

Text of the manual

IDS Two Channel Remote Receiver

IDS Two Channel Remote Receiver IDS Two Channel Remote Receiver • The Normally Open (NO), Normally Closed (NC) IDS Two Channel Receiver (Digital) P/N 860-06-0005 Specifications Power Supply 12V - 16V DC Max. Power Consumption 175mA Weight 145g Dimensions (H x W x L) 33 x 66 x 104 2. Features • Two channel receiver • High noise immunity • 238 Users + 64 supervised RF devices may be learned • Signal Jamming Detection and Ambient Noise Level indication • Advanced RF anti-collision software • Individual relay pulse periods selectable up to 10 minutes • Dedicated panic remotes may be learned • Selectable retrigger protection on any relay • Panel arming / disarming / stay arming and panic through keypad bus • Expansion of panel zones with RF devices such as RF passives. 3. Introduction The IDS Digital Wireless Receiver is an extremely versatile receiver unit that may be used either as a standalone product or in conjunction with any DIGITAL IDS alarm panel such as the IDS 816, 1224 or 1632. When used with a DIGITAL IDS alarm panel, the receiver connects onto the same communication and power bus as the keypad and no other connections are needed to make use of any of the advanced receiver functions. 4. Installation and Wiring • The IDS Digital Wireless receiver may be used in either a standalone mode or connected to an IDS and Common (COM) outputs of both relays are available to be connected to external devices such as gate operators or other alarm panels. • Relay 4ís NO contact is only available with jumper 6 in position 2. When Jumper 6 is in position 1 Relay 4ís NO contact is connected to ground via the tamper switch on the receiver. • For ease of programming Jumper 5 may be used to remove power to the unit after installation. 5. Switches, Jumpers, and Relays • The IDS Digital Wireless Receiver has 8 DIP switches, 1 Tamper switch and 2 Jumpers • The 8 DIP switches are used to program the receiver and adjust its available features. When connected to an IDS DIGITAL alarm panel the programming of users and RF devices such as RF Passives are done through the panel keypad. The programming of any of the other features does however still need to be done using the DIP switches. • Jumper 5 is the power jumper that may be used to remove power from the unit when required to do so during programming. • Jumper 6 selects between Relay 4ís NO contact or the Tamper Switch Contact. The tamper switch is internally connected to ground. • Any of the relay outputs may be used to switch a maximum of 3A at a maximum of 24V DC. The relays are not intended for switching high voltage Colour White Channels 2 Users 238 Passives (Supervised) 64 • • DIGITAL alarm panel. When used in standalone mode, the receiver needs a supply of between 12V and 16V DC. The Data lines D+ and D- do not need to be connected. When connected to a DIGITAL IDS alarm panel, the D+ and D- data lines must be connected to the panelís D+ and D- data lines. (Connection of relays to arm and disarm the panel via zones is NOT needed. Arming and disarming of the panel is done through the data bus.) signals directly such as lights or motors. IDS IDS 700-284-5 AUG 2005 VER 1.40 IDS IDS 1 2 3

IDS Two Channel Remote Receiver

IDS Two Channel Remote Receiver IDS Two Channel Remote Receiver 6. Programming the Unit in Stand-Alone Mode. (Power Up Settings) N.B. to change any settings on the receiver unit, the receiver needs to be powered down, the settings changed and then powered up again. Restoring the Factory Default Settings: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 1, 5, 6, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Switch DIP Switch 8 OFF. 5. Wait for the LEDís to start flashing alternately. 6. Switch ALL Dip switches OFF. 7. When the LEDís stop flashing the unit is in the normal operating mode. The factory default settings with all Dip switches OFF and all jumpers ON are as follow: Three Minute Retrigger Protect Off Remote Learn Off Panic Remote Learn Off RF Device Learn Off Ambient Noise Level Test Off Device Failure Relay Disabled Panic Relay Enabled 3 Sec Remote Panic Enabled Relays Pulse Relay 4 Output Selected Power Jumper On Relay Pulse Period 3 Sec Relays Safe / Secure Secure Panic Relay Relay 4 RF Device Output Relay None Remote Button Outputs Button 1 Relay 1 3 Sec Hold for Panic Button All Relay 3 Min Retrigger Protect None Signal Jamming Detect Period 30s Device Not Reporting 1hr max Deleting ALL the User Remotes: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 2, 5, 6, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Switch DIP Switch 8 OFF. 5. Wait for the LEDís to start alternating. 6. Switch ALL DIP switches OFF. 7. When the LEDís stop flashing the unit is in the normal operating mode. Deleting ALL Supervised RF Devices (e.g. RF Passive IR’s): 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 3, 5, 6, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Switch DIP Switch 8 OFF. 5. Wait for the LEDís to start flashing alternately. 6. Switch ALL DIP switches OFF. 7. When the LEDís stop flashing the unit is in the normal operating mode. Adjusting the Relay Pulse Periods: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. To adjust relay 1ís pulse period, switch DIP switch 1 ON.* 5. Wait for as long as the pulse needs to be (Up to 10 minutes). 6. Switch DIP switch 1 OFF (For relay 1ís pulse period). 7. Switch DIP switch 8 OFF. 8. Wait for the LEDís to start flashing alternately. 9. Switch ALL DIP switches OFF. 10. When the LEDís stop flashing the unit is in the normal operating mode. Changing Between Relay Safe and Secure Modes: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 6 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. To make Relay 1 and 4 Fail Safe, switch DIP switches 1 and 4 ON.* (Any relay not selected will be Fail Secure.) 5. Switch DIP switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL DIP switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. Selecting the Panic Relay Output: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 6, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Select the relay to be the Panic Relay.* (If no relay is selected, the panic relay will be disabled.) 5. Switch DIP switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL DIP switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. * * Where indicated DIP switch 1 represents Relay 1, DIP switch 4 represents Relay 4. IDS IDS 700-284-5 AUG 2005 VER 1.40 IDS IDS 4 5 6

IDS Two Channel Remote Receiver

IDS Two Channel Remote Receiver IDS Two Channel Remote Receiver Selecting the Relay to Activate When a Remote Button is Pressed: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 5 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Select the relay to be the new Output Relay.* (If no relay is selected, no relay will be activated when the remote button is pressed.) 5. Press the button on a learned remote that must activate the selected relay output. 6. Switch DIP switch 8 OFF. 7. Wait for the LEDís to start flashing alternately. 8. Switch ALL DIP switches OFF. 9. When the LEDís stop flashing the unit is in the normal operating mode. Protecting Relays from retriggering within 3 minutes after a previous trigger: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 5, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Select the relay(s) to be retrigger protected.* 5. Switch DIP switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL DIP switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. Assigning a Relay to be Activated when a RF Device is Triggered: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 5, 6 and 8 ON. 3. Restore Power to the Unit by replacing J5 4. Select the relay to be activated.* (If no relay is selected, no relay will be activated when the remote button is pressed.) 5. Trigger the device that must activate the selected Relay Output. 6. Switch Dip switch 8 OFF. 7. Wait for the LEDís to start flashing alternately. 8. Switch ALL Dip switches OFF. 9. When the LEDís stop flashing the unit is in the normal operating mode. Assigning a Dedicated Panic Button to a Remote: N.B. This Function will affect ALL remotes. 1. Remove power from the unit by removing jumper J5 and switch all Dip switches OFF. 2. Switch Dip switches 4 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Press the button on a known remote that will become an instant panic button. 5. Switch Dip switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL Dip switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. Assigning an Arm / Disarm Button on a Remote: N.B. This Function will affect ALL remotes. 1. Remove power from the unit by removing jumper J5 and switch all Dip switches OFF. 2. Switch Dip switches 3 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Press the button on a known remote that will become the Arm / Disarm button. 5. Switch Dip switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL Dip switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. Assigning a Stay Arm Button on a Remote: N.B. This Function will affect ALL remotes. 1. Remove power from the unit by removing jumper J5 and switch all Dip switches OFF. 2. Switch Dip switches 2 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Press the button on a known remote that will become the Stay Arm button. 5. Switch Dip switch 8 OFF. 6. Wait for the LEDís to start flashing alternately. 7. Switch ALL Dip switches OFF. 8. When the LEDís stop flashing the unit is in the normal operating mode. Assigning the Device Failure Output Relay: 1. Remove power from the unit by removing jumper J5 and switch all Dip switches OFF. 2. Switch Dip switches 4, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Switch Dip switch 4 OFF. 5. Select the relay to be the Device Failure Relay.* (If no relay is selected, the device failure relay will be disabled.) 6. Switch Dip switch 8 OFF. 7. Wait for the LEDís to start flashing alternately. 8. Switch ALL Dip switches OFF. 9. When the LEDís stop flashing the unit is in the normal operating mode. Learning a New RF Device such as a RF Passive IR: 1. Remove power from the unit by removing jumper J5 and switch all Dip switches OFF. 2. Switch Dip switches 3, 7 and 8 ON. 3. Restore Power to the Unit by replacing J5. 4. Press the TAMPER switch on the Device to be Learned. 5. Switch Dip switch 8 OFF. 6. Remove power from the unit and adjust Dip switch setting as needed. 7. Restore power to the unit. When the LEDís stop flashing the unit will be in normal operating mode. * * Where indicated DIP switch 1 represents Relay 1, DIP switch 4 represents Relay 4. IDS IDS 700-284-5 AUG 2005 VER 1.40 IDS IDS 7 8 9

IDS Two Channel Remote Receiver

IDS Two Channel Remote Receiver IDS Two Channel Remote Receiver 7. Programming the Unit in Stand-Alone Mode. (Normal Settings) These settings may be adjusted during normal operation and it is not necessary to power the unit down for the settings to take effect. Remote Arm or Disarm 3 Minute Retrigger Protecting: 1. Switch Dip switch 2 ON to enable retrigger protecting. Learning New Remotes: 1. Switch DIP switch 3 ON to enable learning of new remotes. 2. Press any button on the remotes to be learned. 3. Switch DIP switch 3 OFF to exit the learn mode. To indicate the Ambient Noise Level: N.B. This function must be disabled during normal operation This function allows the testing of ambient noise in 2. Press any button on the remotes to be learned. 3. Switch DIP switch 6 OFF to exit the learn mode. Disable the 3 second Hold for Panic Feature: 1. To disable the 3 second hold for panic feature on ALL remotes switch DIP switch 7 ON. Changing the Relays from Pulsing to Toggling: 1. Remove power from the unit by removing jumper J5 and switch all DIP switches OFF. 2. Switch DIP switches 5, 6, 7 & 8 on. 3. Restore the power to the Unit by replacing J5. 4. To select toggling relays, use DIP switches 1 & 4 for Relays 1 & 4. 5. Switch DIP switch 8 off. 6. Wait for the LEDís to start alternating. 7. Switch all DIP switches off and set DIP switches 9. Connector, Switch and Jumper Positions 10. Program Summary and LED Indications: the environment surrounding the receiver during to the desired setting. Switch Settings 1 2 3 4 5 6 7 8 R G Function installation. 1. Switch DIP switch 4 ON to enable noise level testing. 2. ONLY install the receiver in an environment with normal or better noise Levels. During noise testing the LEDís indicate the following: 8. Programming a Unit Connected to a DIGITAL IDS alarm panel. When connected to a DIGITAL IDS alarm panel, programming of the unit is as for the Stand-Alone mode with the following exceptions. ~ ~ ~ ~ ~ ~ 1 0 1 0 PANIC DISABLE ~ ~ ~ ~ ~ 1 ~ 0 1 2 LEARN PANIC ~ ~ ~ ~ 1 ~ ~ 0 2 0 ERROR RELAY ~ ~ ~ 1 ~ ~ ~ 0 1 0 TEST NOISE ~ ~ 1 ~ ~ ~ ~ 0 1 4 LEARN ~ 1 ~ ~ ~ ~ ~ 0 1 0 RETRIG PROTECT 1 ~ ~ ~ ~ ~ ~ 0 1 0 0 0 0 0 0 0 1 1 3 0 PULSE PERIOD RED LED GREEN LED NOISE LEVEL Learning and Deleting Individual User Remotes: 1. To learn a new user remote, leave DIP switch 3 0 0 0 0 0 1 0 1 4 3 SAFE/SECURE 0 0 0 0 0 1 1 1 4 0 PANIC RELAY 0 0 0 0 1 0 0 1 4 1 RELAY FOR OFF OFF VERY LOW ON (it need not be switched OFF for normal operation when connected to an IDS DIGITAL 0 0 0 0 1 0 1 1 3 1 RELAY RETRIGGER 0 0 0 0 1 1 0 1 0 4 RELAY FOR DEVICE OFF SLOW LOW alarm panel). 0 0 0 1 0 0 0 1 0 3 PANIC BUTTON OFF FAST NORMAL 2. Follow the user manual of the DIGITAL IDS alarm 0 0 1 0 0 0 0 1 0 3 ARM BUTTON 0 1 0 0 0 0 0 1 0 3 STAY BUTTON SLOW ONHIGH panel for learning new users. 0 0 0 1 0 0 1 1 2 1 ERROR RELAY FAST ONVERY HIGH Learning New Supervised RF Devices and deleting 0 0 1 0 0 0 1 1 1 3 LEARN DEVICE 0 1 0 0 0 0 1 1 3 2 RECEIVER ID ON ON POSSIBLE JAMMING Devices by Zone allocation: 1. Follow the user manual of the DIGITAL IDS alarm 0 0 0 0 1 1 1 1 1 2 ELAY PULSE / TOGGLE 0 0 1 0 1 1 1 1 4 4 DELETE DEVICES Enabling the Device Failure Relay Output: 1. Switch DIP switch 5 ON panel for learning new RF devices and deleting RF devices by zone. 0 1 0 0 1 1 1 1 4 4 DELETE REMOTES 1 0 0 0 1 1 1 1 3 3 FACTORY RESETS Learn New Panic Remotes: 1. Switch DIP Switch 6 ON IDS IDS 700-284-5 AUG 2005 VER 1.40 IDS 0 = OFF 1 = ON 2 = BLINK 3 = FAST 4 = SLOW 5 = ALT R = RED LED G = GREEN LED 3 4 MEMORY FULL 1 1 BUSY SIGNAL 0 0 INVALID SIGNAL 5 5 LOW BATT IDS 10 11 12

Other Receiver Manuals