IDS Keypad Bus
Remote Receiver
(Digital - No Relays)
2.
Features
•
Four channel receiver
•
High noise immunity
•
238 Users + 64 supervised RF devices may be
learned
•
Signal Jamming Detection and Ambient Noise
Level indication
•
Advanced RF anti-collision software
•
Panel arming / disarming / stay arming and panic
through keypad bus
•
Expansion of panel zones with RF devices such
6.
RF Passives are done through the panel keypad.
The programming of any of the other features does
however still need to be done using the Dip
switches.
•
Jumper 5 is the power jumper that may be used to
remove power from the unit when required to do
so during programming.
Programming the Unit in Stand -
Alone Mode. (Power Up Settings)
3.
as RF passives.
Introduction
N.B. to change any settings on the receiver unit, the
receiver needs to be powered down, the settings
changed and then powered up again.
P/N 860-06-0004
The IDS Digital Wireless Receiver is an extremely versatile
receiver unit that may be used in conjunction with any
DIGITAL IDS alarm panel such as the IDS 816, 1224 or
1632. When used with a DIGITAL IDS alarm panel, the
receiver connects onto the same communication and power
bus as the keypad and no other connections are needed
to make use of any of the advanced receiver functions.
Restoring the Factory Default Settings :
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
2. Switch Dip switches 1, 5, 6, 7 and 8 ON
3. Restore Power to the Unit by replacing J1
4. Switch Dip Switch 8 OFF
5. Wait for the LED’s to start flashing alternately.
Specifications
Power Supply
12V - 16V DC
Max. Power Consumption
175mA
Weight
145g
Dimensions (H x W x L)
33 x 66 x 104
Colour
White
Users
238
Passives (Supervised)
64
4.
5.
Installation and Wiring
•
When connected to a DIGITAL IDS alarm panel,
the D+ and D- data lines must be connected to the
panel’s D+ and D- data lines.
•
For ease of programming Jumper 5 may be used
to remove power to the unit after installation.
Switches and Jumpers
•
The IDS Digital Wireless Receiver has 8 Dip
switches, 1 Tamper switch and 1 Jumper.
•
The 8 Dip switches are used to program the
receiver and adjust its available features. When
connected to an IDS DIGITAL alarm panel the
programming of users and RF devices such as
6. Switch ALL Dip switches OFF.
7. When the LED’s stop flashing the unit is in the
normal operating mode
The factory default settings with all Dip switches
OFF and all jumpers ON are as follow:
Three Minute Retrigger Protect
Off
Remote Learn
Off
Panic Remote Learn
Off
RF Device Learn
Off
Ambient Noise Level Test
Off
3 S ec Remote Panic
Enabled
Power Jumper
On
Arm / Disarm Button
Button 1
Stay Arm Button
Button 2
Instant Panic Button
None
IDS
IDS 700-284-4 B August 2007
IDS
IDS
1
2
3
IDS Keypad Bus Remote Receiver
IDS Keypad Bus Remote Receiver
IDS Keypad Bus Remote Receiver
3 Sec Hold for Panic Button
All
Signal Jamming Detect Period
30s
Device Not Reporting
1hr max
Deleting ALL the User Remotes :
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
2. Switch Dip switches 2, 5, 6, 7 and 8 ON
3. Restore Power to the Unit by replacing J1
4. Switch Dip Switch 8 OFF
5. Wait for the LED’s to start alternating
6. Switch ALL Dip switches OFF.
7. When the LED’s stop flashing the unit is in the
normal operating mode
Deleting all Supervised RF Devices
(e.g. RF Passive IR's) :
8. When the LED’s stop flashing the unit is in the
normal operating mode
Assigning an Arm / Disarm Button on a Remote :
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
2. Switch Dip switches 3 and 8 ON
3. Restore Power to the Unit by replacing J1
4. Press the button on a known remote that will
become the Arm / Disarm button.
5. Switch Dip switch 8 OFF.
6. Wait for the LED’s to start flashing alternately.
7. Switch ALL Dip switches OFF.
8. When the LED’s stop flashing the unit is in the
normal operating mode.
Assigning a Stay Arm Button on a Remote :
Remote Arm or Disarm 3 Minute Retrigger Protecting :
1. Switch Dip switch 2 ON to enable retrigger
protecting.
To indicate the Ambient Noise Level :
N.B. This function must be disabled during normal
operation
This function allows the testing of ambient noise in the
environment surrounding the receiver during
installation.
1. Switch Dip switch 4 ON to enable noise level
testing.
2. ONLY install the receiver in an environment with
Normal or Better Noise Levels.
During Noise Testing the LED’s indicate the following:
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
2. Switch Dip switches 3, 5, 6, 7 and 8 ON
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
OFF
RED
LED
OFF
GREEN
LED
NOISE
LEVEL
VERY LOW
3. Restore Power to the Unit by replacing J1
4. Switch Dip Switch 8 OFF
5. Wait for the LED’s to start flashing alternately.
6. Switch ALL Dip switches OFF.
7. When the LED’s stop flashing the unit is in the
normal operating mode
2. Switch Dip switches 2 and 8 ON
3. Restore Power to the Unit by replacing J1
4. Press the button on a known remote that will
become the Stay Arm button.
5. Switch Dip switch 8 OFF.
6. Wait for the LED’s to start flashing alternately.
7. Switch ALL Dip switches OFF.
OFF
OFF
SLOW
FAST
ON
SLOW
FAST
ON
ON
ON
LOW
NORMAL
HIGH
VERY HIGH
POSSIBLE JAMMING
Assigning a Dedicated Panic Button to a Remote :
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing jumper
J1 and switch all Dip switches OFF.
2. Switch Dip switches 4 and 8 ON
3. Restore Power to the Unit by replacing J1
7.
8. When the LED’s stop flashing the unit is in the
normal operating mode.
Programming the Unit in Stand -
Alone Mode. (Normal Settings)
Learn New Panic Remotes :
1. Switch Dip Switch 6 ON
2. Press any button on the remotes to be learned.
3. Switch Dip switch 6 OFF to exit the learn mode.
Disable the 3 second Hold for Panic Feature :
4. Press the button on a known remote that will
become an instant panic button.
5. Switch Dip switch 8 OFF.
6. Wait for the LED’s to start flashing alternately.
7. Switch ALL Dip switches OFF.
These settings may be adjusted during normal
operation and it is not necessary to power the unit
down for the settings to take effect.
1. To disable the 3 second hold for panic feature on
ALL remotes switch Dip switch 7 ON.
IDS
IDS 700-284-4 B August 2007
IDS
IDS
4
5
6
IDS Keypad Bus Remote Receiver
IDS Keypad Bus Remote Receiver
IDS Keypad Bus Remote Receiver
8.
Programming a Unit Connected to a
Digital IDS alarm panel.
10.
Program Summary and LED Indications
Learning and Deleting Individual User Remotes :
Switch Settings
1 2 3 4 5 6 7 8
R G
Function
1. To learn a new user remote, leave Dip switch 3
ON. (it need not be switched OFF for normal
operation when connected to an IDS DIGITAL
alarm panel)
2. Follow the user manual of the DIGITAL IDS alarm
panel for learning new users.
Learning new supervised RF devices and deleting
devices by zone allocation :
1. Follow the user manual of the DIGITAL IDS alarm
panel for learning new RF devices and deleting
~ ~ ~ ~ ~ ~ 1 0
1 0 PANIC DISABLE
~ ~
~ ~ ~ 1 ~ 0
1 2 LEARN PANIC
~ ~
~ 1 ~ ~ ~ 0
1 0 TEST NOISE
~ ~
1 ~ ~ ~ ~ 0
1 4 LEARN
1 ~ ~ ~ ~ ~ ~ 0
1 0
0 0 0 1 0 0 0 1 0 3 PANIC BUTTON
0 0 1 0 0 0 0 1 0 3 ARM BUTTON
0 1 0 0 0 0 0 1 0 3 STAY BUTTON
0 0 1 0 0 0 1 1 1 3 LEARN DEVICE
0 1 0 0 0 0 1 1 3 2 RECEIVER ID
0 0 1 0 1 1 1 1 4 4 DELETE DEVICES
0 1 0 0 1 1 1 1 4 4 DELETE REMOTES
1 0 0 0 1 1 1 1 3 3 FACTORY RESETS
9.
RF devices by zone.
Connector, Switch and Jumper Positions
0 = OFF
1 = ON
2 = BLINK
3 = FAST
4 = SLOW
5 = ALT
R = RED LED
G = GREEN LED
3 4 MEMORY FULL
1 1 BUSY SIGNAL
0 0 INVALID SIGNAL
5 5 LOW BATT
ON
1 2 3 4 5 6 7 8
+ 12V
GND
D -
D +
IDS
IDS 700-284-4 B August 2007
IDS
IDS
7
8
9