Studio Technologies 5401A Operation & User’s Manual
Read Online
Read the Studio Technologies 5401A Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
50701-0721, Issue 2
Copyright © 2021 by Studio Technologies, Inc., all rights reserved
studio-tech.com
User Guide
Issue 2, July 2021
This User Guide is applicable for serial numbers
M5401A-01001 and later with Main MCU Firmware 1.04 and later
Model 5401A
Dante® Leader Clock
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 3
Table of Contents
Revision History ................................................................................................................. 4
Introduction ......................................................................................................................... 5
Installation .......................................................................................................................... 9
Dante Configuration ........................................................................................................... 12
Model 5401A Configuration ................................................................................................ 15
Operation ............................................................................................................................ 29
Technical Notes .................................................................................................................. 40
Specifications ..................................................................................................................... 45
Appendix A–Compatible Sync Input Sources ..................................................................... 47
Appendix B–Network Configuration Examples ................................................................... 48
Appendix C–Dante Controller Network Default Configuration Values ................................ 51
Appendix D–Menu Structure .............................................................................................. 52
Appendix E–Screen Captures ............................................................................................ 53
Appendix F–Model 5401A Default Configuration Values .................................................... 58
Appendix G–PTPv2 (IEEE® 1588-2008) Default Characteristics ...................................... 59
Appendix H–Accessing the Unit when User Name and/or Password are Not Known ....... 60
Issue 2, July 2021
Model 5401A User Guide
Page 4
Studio Technologies, Inc.
Revision History
Issue 2, July 2021:
• Documents support for 176.4 and 192 kHz sample rates.
• Miscellaneous corrections and clarifications.
Issue 1, May 2021:
• Initial release.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 5
Introduction
The Model 5401A Dante Leader Clock pro-
vides precise timing signals for applications
that utilize the Dante audio-over-IP media
networking technology. The unit implements
a high-performance IEEE® 1588 precision
time protocol (PTP) server, compatible with
the requirements of Dante and capable of
simultaneously supporting the timing needs
of up to hundreds of Dante-compatible
devices. As expected, the Model 5401A
provides the PTPv1 (IEEE 1588-2002)
compatibility that’s required by Dante.
In addition, the unit supports PTPv2 (IEEE
1588-2008) for AES67 applications. A word
clock output provides a general-purpose
timing reference for use by external devic-
es. The Model 5401A also generates eight
sine wave audio tones on Dante transmit-
ter (output) channels which can be useful
during audio and data network installation,
maintenance, and operation. A sync input
connection allows the Model 5401A’s in-
ternal oscillator to be synchronized with a
variety of timing and reference signals.
The Model 5401A is suitable for use in fixed
and mobile broadcast facilities, post-pro-
duction studios, commercial and education-
al theater environments, and entertainment
applications. Only power and one, two, or
three Ethernet network connections are
required for full operation. Using Dante’s
inherent capabilities two Model 5401A units
can serve in primary and backup Leader
clock roles for redundant operation.
The unit’s three Gigabit Ethernet (GigE)
network interfaces can be configured for
use in a range of network implementations.
For high-reliability audio applications two
of the interfaces can support Dante redun-
dancy operation while the third is used for
accessing the management webpages. To
meet the latest interoperability standard the
Model 5401A’s Dante implementation sup-
ports AES67-2018. The unit also integrates
with the Dante Domain Manager™ (DDM)
software application.
An integrated web server allows fast and
flexible monitoring and configuration of
the unit’s networking, clocking, and Dante
performance. Front-panel LED indicators,
an LCD display, and pushbutton switches
provide users with direct access to key
operating parameters.
The Model 5401A can be powered by 100-
240 V, 50/60 Hz mains or a source of 12
volts DC. Both can be simultaneously con-
nected to provide redundant operation. The
lightweight enclosure mounts in one space
(1U) of a 19-inch equipment rack. Industry-
standard connectors are used for Ethernet,
DC power, and AC mains interconnections.
Updating the Model 5401A’s operating
software can be easily performed using a
standard USB flash drive.
Figure 1. Model 5401A Dante Leader Clock front and back views
Issue 2, July 2021
Model 5401A User Guide
Page 6
Studio Technologies, Inc.
Applications
Applications for the Model 5401A include
broadcast and post-production facilities,
college and university audio networks, are-
nas, stadiums, corporate installations, and
virtually any application where substantial
numbers of Dante-compatible devices are
utilized. The Model 5401A will serve as a
stable and consistent Leader clock for the
entire Dante “network.” And, as expected,
the Model 5401A is compatible with all
Dante devices, no matter what their function
or manufacturer. Applications that utilize
devices compatible with AES67 will also
benefit from the Model 5401A’s resources.
Why a Dedicated Dante
Leader Clock?
With Dante ubiquitous in fixed and mobile
facilities of all sizes and types, the need
arose for a cost-effective, purpose-
designed, dedicated Leader clock. While
an inherent strength of Dante networking
is its carefully implemented use of the IEEE
1588 standard to ensure that all connected
devices maintain a common timing refer-
ence, the actual performance can vary
widely depending on the specific Dante
devices in use and the overall number of
devices on a network. There are many
Dante-compatible devices that can provide
adequate basic performance as a Leader
clock, but with the Model 5401A networked
audio systems get the benefits of a high-
performance Primary Leader Clock, along
with additional unique capabilities. The
unit’s feature set, along with the associ-
ated internal hardware and software, was
designed to provide optimum performance,
flexibility, and system integrity.
Timing Sources
The Model 5401A can provide excellent
Leader clock performance using its tem-
perature- stabilized internal oscillator, which
exceeds the capability of standard Dante
devices by at least an order of magnitude.
While its standalone performance is excel-
lent, the Model 5401A can also be “locked”
to a variety of external signals for integra-
tion into facilities that include a central or
main timing reference. Compatible signals
include word clock, video reference, and
10 MHz.
Word clock is a square wave signal that is
often used as a timing reference in audio-
only facilities. Several common word clock
rates, including 48, 96 kHz, and the more-
exotic 192 kHz, are compatible with the
Model 5401A’s sync input. Video reference
(“sync”) signals are found in most broadcast
and post-production facilities. The Model
5401A supports the most-common video
format/rate combinations including “black
burst,” bi- and tri-level HD, and several that
are specifically intended for 4K applications.
Industrial and commercial facilities often uti-
lize a GPS-disciplined source of 10 MHz as
a timing reference. This sine wave signal is
typically compatible with the Model 5401A’s
sync input.
Word Clock Output
The Model 5401A generates a precise word
clock output signal that can be used as a
timing reference for related equipment. It’s
specifically intended for “locking” digital
audio devices in applications that use the
Model 5401A to provide timing reference
signals for the associated Dante equipment.
In this way, all devices in an installation will
share a common timing reference.
The word clock output rate can be 44.1, 48,
88.2, 96, 176.4, or 192 kHz. The underlying
timing source for the word clock output is
derived from the Model 5401A’s main timing
source. As previously reviewed, the internal
oscillator, if desired, can be “locked” to an
external source. The main timing source
is divided and processed by the Model
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 7
5401A’s logic circuitry to create the highly
stable word clock output. This ensures that
the word clock output is synchronized with
the unit’s PTPv1 and PTPv2 server func-
tionality.
Audio Tone Generator
The Model 5401A generates eight sine
wave audio tones intended for general-pur-
pose use. These audio tones are available
from the Model 5401A by way of Dante
transmitter (output) channels and can be
connected, using the Dante Controller ap-
plication, to Dante receivers (inputs) on
related equipment. The flexibility of being
able to interconnect signals (create Dante
“subscriptions”) between all Dante devices
on a network allows the audio tones to be
used for a variety of purposes. Configura-
tion choices allow the frequency and level
of each sine wave tone to be optimized for
use in specific applications.
Leader Clock Support for
Dante Networks
A core part of the technology underlying
Dante audio-over-IP networking ensures
that all connected devices follow a com-
mon timing reference. This is accomplished
using the PTPv1 (IEEE 1588-2002) and
PTPv2 (IEEE 1588-2008) precision time
protocols. Any connected Dante device
can be used as a Leader clock; there is no
requirement that a dedicated Leader clock
device be utilized to realize adequate func-
tionality. However, the actual performance
can vary widely depending on the specific
Dante devices available and the overall
number of Dante devices on a network.
Many Dante devices utilize the 2- or 4-
channel Ultimo™ ULT or UXT integrated
circuits to implement Dante connectiv-
ity. While Ultimo devices will fully support
Dante audio transport, they are not well
suited to serve as a Leader clock. Ultimo’s
PTP performance is limited and does not
have the ability to synchronize with an
external timing reference. Other Dante
devices may use the Brooklyn II module
or Broadway integrated circuit to support
Dante connectivity. In some cases, these
devices can provide good basic perfor-
mance as a Leader clock.
However, problems and limitations may
arise when these devices are called upon
to perform “double duty,” serving in both a
primary function (such as analog-to-Dante
interfacing or audio signal processing) as
well as acting as a Leader clock. This is un-
derstandable as the main purpose of these
devices is to serve functions other than act-
ing as a primary synchronization reference.
Timing related features, such as allowing
connection of a video bi- or tri-level sync
signal is rarely, if ever, supported. And PTP
performance can degrade when the com-
puting power of a device is intended pri-
marily for handling and manipulating digital
audio signals. This can lead to the required
PTP resources being in short supply when
the number of Dante devices that need
timing messages moves into the hundreds.
Also, firmware updates, cabling changes,
and other maintenance tasks typically asso-
ciated with a general-purpose Dante device
would impact the Leader clock functionality
for an entire installation.
The Model 5401A was specifically designed
to support a Dante-based audio system’s
Leader clock requirement. And the unit’s
generation of audio tones and implementa-
tion of the word clock output utilize hard-
ware circuitry that is separate from that
associated with its PTP functionality. As
such, this secondary functionality will not
interfere with PTP operation. Unlike a
general-purpose Dante device, once mount-
ed in an equipment rack and the required
Issue 2, July 2021
Model 5401A User Guide
Page 8
Studio Technologies, Inc.
interconnections are made, the Model
5401A will perform its tasks without risk
of interruption due to conflicting resource
demands.
Flexible Networking
Capability
Using the Dante Controller application
program, the Model 5401A’s three Eth-
ernet ports can be selected to operate in
one of four modes: Switched, Redundant,
Switched+Mgmt, and Redundant+Mgmt.
This should allow virtually any desired
networking implementation to be easily
achieved.
By using the Switched or Redundant net-
work modes, separate network connections
will be maintained for Dante audio and
management purposes.
In the Switched mode a single Ethernet
connection to either of the Model 5401A’s
two Dante Ethernet ports will provide Dante
Leader clock functionality. The remain-
ing Dante Ethernet port will provide Dante
network “loop-through” capability and can
be used to interface with another piece
of Ethernet-connected equipment. The
management Ethernet port will be used to
access the Model 5401A’s monitoring and
configuration webpages.
In the Redundant mode two independent
Ethernet connections are made to the
Model 5401A’s two Dante Ethernet ports,
enabling Dante’s redundant networking
capability. Again, the management Ether-
net port will be used to access the Model
5401A’s monitoring and configuration
webpages.
In the Switched+Mgmt mode a single Ether-
net connection is used for both Dante Lead-
er clock functionality as well as providing
access to the Model 5401A’s management
webpages. The remaining Dante Ethernet
port will provide network “loop-through”
capability and can be used to interface
with another piece of Ethernet-connected
equipment.
In the Redundant+Mgmt mode two inde-
pendent Ethernet connections can be made
to the Model 5401A’s two Dante Ethernet
ports. This will enable Leader clock ca-
pability for applications that utilize Dante
redundancy. Access to the Model 5401A’s
management webpages will be made by
way of the Ethernet connection made to the
Dante primary Ethernet port.
Operating Power
The Model 5401A allows an AC mains
source of 100-240 V, 50/60 Hz to be directly
connected. It can also be DC powered us-
ing a 10-18 volt source that is connected via
a broadcast-standard 4-pin XLR connector.
If both AC and DC power sources are con-
nected the unit will be powered by the AC
mains supply. Only if the AC mains source
fails will appreciable power be drawn from
the DC source. This allows a source of DC,
typically an external power supply, to serve
in a backup capacity. With this arrangement
normal operation can continue even if AC
mains power is lost.
Future Capabilities
The Model 5401A was designed so that its
capabilities can be enhanced in the future.
A USB receptacle located on the unit’s
back panel, allows the three firmware files
(embedded software) to be updated us-
ing a USB flash drive. The Model 5401A’s
Dante firmware can be updated using one
of the unit’s Ethernet connections, helping
to ensure that the Dante capabilities remain
up to date. All software files and configura-
tion parameters are stored in non-volatile
memory.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 9
Installation
In this section the Model 5401A will be
mounted in one space (1U) of an equipment
rack. In many cases, an external synchroni-
zation source will be connected to the sync
input BNC jack. If needed, a connection may
be made to the word clock output BNC jack
on the back panel. One or more Ethernet
data connections will be made. AC mains
and/or DC power will be connected to the
Model 5401A.
Using a coaxial cable terminated with a BNC
plug, an external source of synchronization
may be connected to the sync input. A word
clock output is provided by way of a BNC
jack and may be utilized by one or more
pieces of equipment. Up to three Ethernet
data connections will be made to the Model
5401A using standard RJ45 patch cables.
AC mains power can be connected to the
Model 5401A by means of a detachable cord
that is compatible with the unit’s 3-pin IEC
320 C14 inlet connector. Some applications
may warrant connection to a source of nomi-
nal 12 volts DC which can be made by way
of a 4-pin XLR connector. A DC source can
be used to power the Model 5401A as well
as serving as a backup power source should
AC mains not be present.
What’s Included
The shipping carton contains a Model 5401A
Dante Leader Clock and instructions on how
to obtain an electronic copy of this guide.
Also included in the shipping carton is a
North-American-standard AC mains cord.
For destinations outside of North America
the local reseller or distributor should pro-
vide an appropriate AC mains cord.
Mounting the Model 5401A
The Model 5401A Dante Leader Clock re-
quires one space (1U) in a standard 19-inch
(48.3 cm) equipment rack. Secure the unit
into the designated equipment rack using
two mounting screws per side. As the Mod-
el 5401A does not contain a fan or other
noise-producing source it can be located
within a room or other structure where au-
dio monitoring is going to take place. Some
or all of the connections involving the sync
input BNC jack, the word clock output BNC
jack, the Ethernet interface RJ45 jacks, and
the AC mains and/or DC power connectors
may be utilized.
Twisted-pair (UTC) Ethernet has a 100-
meter (325-foot) interconnection cable limi-
tation. But that can be overcome by using
fiber-optic interconnections between the
Model 5401A and the Ethernet switch or
switches in the one or more associated
local-area-networks (LANs).
Sync Input
An external synchronization source can be
connected to the Model 5401A’s sync input
BNC jack. Located on the back panel, this
input allows the Model 5401A’s internal tim-
ing to be “locked” to an external reference.
Signals that are compatible with the Model
5401A’s sync input include word clock, bi-
level video, tri-level video, and 10 MHz sine
wave. A configuration setting in the Sync
Input webpage defines what type of signal
is going to be connected. Another setting
defines if a termination impedance is ap-
plied to the sync input. Refer to the Specifi-
cations section of this guide for the general
characteristics required of acceptable exter-
nal sync signals.
A connected word clock signal must be a
square wave with a rate that matches the
Dante sample rate as defined in the Dante
Controller application. The rate can be 44.1,
48, 88.2, 96, 176.4, or 192 kHz. If termina-
tion has been enabled for the sync input
when it has been configured for word clock
an impedance of 75 ohms will be applied.
Issue 2, July 2021
Model 5401A User Guide
Page 10
Studio Technologies, Inc.
A source of bi-level or tri-level video can
also be connected to the sync input. Circuit-
ry within the Model 5401A will decode many
of the common video rates and formats, al-
lowing them to serve as a timing reference.
Refer to Appendix A, located at the end of
this guide, for a list of compatible rates and
formats. If the sync input is configured for
video and termination has been enabled an
impedance of 75 ohms will be applied.
A source of 10 MHz sine wave can be con-
nected to the Model 5401A’s sync input.
This type of signal is commonly used as
a timing reference in industrial and instru-
mentation applications. An impedance of 50
ohms will be applied to the sync input if ter-
mination has been enabled and the source
is selected for 10 MHz.
Word Clock Output
A word clock output signal is provided for
use by other devices that want to be “timed”
from the Model 5401A. Available by way
of a BNC jack located on the back panel,
the square wave output has a frequency
that matches the unit’s configured Dante
sample rate. Choices are 44.1, 48, 88.2, 96,
176.4, and 192 kHz. The exact frequency
of the word clock output is based on the
timing reference that has been selected for
the Model 5401A. If, for example, the Sync
Input was selected as the unit’s timing refer-
ence, then the word clock output would be
“locked” to it.
The source impedance of the word clock
signal is 75 ohms and its unterminated
output level is 5 volts peak-to-peak (Vpp).
When externally terminated with a 75 ohm
load the word clock output level will drop to
2.5 Vpp.
Ethernet Connections
The Model 5401A provides three Giga-
bit Ethernet (GigE) ports for flexibility and
compatibility with many networking imple-
mentations. Two ports are provided for
interconnections with one or two local area
networks (LANs) associated with Dante
audio-over-IP networking schemes. They
are labeled as PRI (primary) and SEC (sec-
ondary). The third Ethernet port, labeled
MGMT, can be used to access the Model
5401A management resources. An internal
web server function supports the Model
5401A’s management port’s webpages.
These webpages are used for configura-
tion, monitoring, and maintenance of Model
5401A operation. Refer to Figure 2 for an
overview of the Model 5401A’s three Ether-
net ports and how they can operate.
Using the Dante Controller application,
the three Ethernet ports can be config-
ured to operate in one of four modes:
Switched, Redundant, Switched+Mgmt, or
Redundant+Mgmt. If configured for either
the Switched or Redundant modes the
management webpages are accessed by
way of the management Ethernet port.
When configured for the Switched+Mgmt
mode the management webpages are
accessed by way of either the primary or
secondary Ethernet ports. When configured
for the Redundant+Mgmt mode the man-
agement webpages are accessed using an
Ethernet connection made to the primary
Ethernet port.
By providing three Ethernet ports and four
configuration modes, the Model 5401A al-
lows support for virtually all facilities, includ-
ing those that utilize separate networks for
Dante audio transport and equipment man-
agement. In this way, “production” networks
that support transport of audio signals by
way of a single LAN (Switched mode) or
two LANs (Redundant mode) can be sepa-
rate from an engineering network that is
used by technical personnel for configuring
and maintaining a facility or “plant.”
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 11
Connections to the three Ethernet interfac-
es are made by way of standard RJ45 jacks
that are located on the back of the Model
5401A’s enclosure. The Ethernet interfaces
support auto MDI/MDI-X so that crossover
cables are not required. Refer to Appen-
dix B, located at the end of this guide, for
examples of how the Model 5401A’s three
Ethernet interfaces might be utilized. It’s dif-
ficult to conceive of a network environment
that the unit wouldn’t be able to effectively
support.
Dante Port Connections
At least one 1000BASE-T (GigE) Ethernet
connection is required for Model 5401A
Dante operation. It should be connected
to the primary RJ45 jack. A second
1000BASE-T (GigE) connection can be
made to the secondary RJ45 jack if Redun-
dant Dante is desired. For this functional-
ity to be active the Model 5401A’s network
configuration must be set for the Redun-
dant or Redundant+Mgmt mode within the
Dante Controller software application. While
technically 100BASE-TX (100 Mb/s) Ether-
net can also be used for these Dante con-
nections, it is not optimal. Additionally, it’s
important to note that 10BASE-T (10 Mb/s)
Ethernet connections are not sufficient.
When configured in Dante Controller for
the Switched or Switched+Mgmt modes the
Model 5401A’s Dante secondary Ethernet
connection can also be used as a “loop
through” port such as would be provided by
an Ethernet switch. Switched mode is the
default setting but using the Dante second-
ary port in this manner for applications other
than troubleshooting or “looping” to access
the Model 5401A’s management port is
not recommended. It will function reliably
but “daisy chaining” Ethernet signals can
limit flexibility and present a failure point;
it’s optimal if each Dante Ethernet interface
connects directly to a separate port on an
Ethernet switch.
Management Port Connection
If required by the needs of an application,
the management webpages can be ac-
cessed using an Ethernet signal connected
to the Model 5401A’s management Ethernet
port. This requires that the network mode in
Dante Controller be configured for Switched
or Redundant. It’s recommended that a
1000BASE-T (GigE) connection be made
but a 100BASE-TX (100 Mb/s) connection
is sufficient. (GigE will provide the best per-
formance and it’s assumed that all contem-
porary applications will support it.)
Access to the Model 5401A’s management
webpages can also be obtained using the
same network connection or connections
that are being used for Dante audio. This
requires that the network mode in Dante
Controller be configured for Switched+Mgmt
or Redundant+Mgmt. Appendix B provides
example of how these network scenarios
can easily be implemented.
Dante Controller Network
Model 5401A Ethernet Port
Switch Configuration
Pri
Sec
Mgmt
Switched
Dante
Management
Redundant
Dante Primary
Dante Secondary
Management
Switched+Mgmt
Dante and Management
Disabled
Redundant+Mgmt
Dante Primary and Management
Dante Secondary
Disabled
Figure 2. Model 5401A Ethernet Port Configuration and Operation
Issue 2, July 2021
Model 5401A User Guide
Page 12
Studio Technologies, Inc.
Connecting Power
The Model 5401A requires a source of AC
mains or nominal 12 volts DC for operation.
Either source can be connected with the
same result. Both can also be simultane-
ously connected if a redundant (backup)
power scheme is desired.
Connecting AC Mains Power
The Model 5401A can operate directly
from AC mains power of 100 to 240 volts,
50/60 Hz, 5 watts maximum. As a “universal
mains input” device there are no switches
to set or jumpers to install. A 3-pin IEC
320 C14 inlet connector on the back panel
mates with a detachable mains cord set.
All units are supplied from the factory
with an AC mains cord that has a North-
American (NEMA 5-15L) standard plug on
one end and an IEC 320 C13 connector
on the other end. Units intended for use in
other destinations require that an appropri-
ate mains cord be obtained. The wire colors
in the mains cord should conform to the
internationally recognized color code and
be terminated accordingly:
Connection
Wire Color
Neutral (N)
Light Blue
Line (L)
Brown
Earth/Ground (E)
Green/Yellow
Because the Model 5401A does not contain
a power on/off switch it will begin operation
as soon as AC mains power is connected.
Safety Warning: The Model 5401A does
not contain an AC mains disconnect
switch. As such, the AC mains cord plug
serves as the disconnection device.
Safety considerations require that the
plug and associated inlet be easily ac-
cessible to allow rapid disconnection
of AC mains power should it prove
necessary.
Connecting DC Power
The Model 5401A can also operate from
a source of 10 to 18 volts DC. The current
required from a 12 volts DC source is 0.5
ampere (500 milliamperes) maximum. A
4-pin male XLR connector, located on the
unit’s back panel, is used to connect the
source of DC. Prepare a mating connec-
tor (female) so that pin 1 is DC– and pin
4 is DC+. Pins 2 and 3 are not used and
should remain unconnected. This connector
type and pinout have become a broadcast
DC power standard and should be familiar
to many technical personnel. Because the
Model 5401A contains no power on/off switch
it will begin operation as soon as a DC power
source is connected.
As previously mentioned, both an AC mains
source and a DC source can be connected
at the same time. If this is the implementation
then the AC mains source will always power
the Model 5401A with the DC source serving
as a “hot standby.” Only if the AC source fails
will the unit draw power from the DC source.
This will occur automatically with no interrup-
tion of Model 5401A operation. In this
“standby” mode (when an AC mains source
is connected) the Model 5401A draws less
than 110 microamperes (uA) from a 12 volts
DC input.
Dante Configuration
For audio and timing to correctly pass from
the Model 5401A requires that several Dante-
related parameters be configured. These
configuration settings are stored in non-
volatile memory within the Model 5401A’s
Dante network interface circuitry. Configu-
ration will typically be done with the Dante
Controller software application, available for
download free of charge at audinate.com.
Refer to Appendix C of the list of the Model
5401A’s Dante Controller default configura-
tion. Versions of Dante Controller are avail-
able to support several operating systems.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 13
The Model 5401A’s Dante interface is com-
patible with the Dante Domain Manager
(DDM) software application. Refer to DDM
documentation, also available from Audi-
nate, for details on which Model 5401A
and related parameters may have to be
configured.
Audio Routing
The Model 5401A’s eight Dante transmitter
(output) channels can be assigned to the
desired Dante receiver (input) channels on
associated equipment. This will route the
eight channels associated with the tone
generator function. Within Dante Controller
a “subscription” is the term used for routing
a transmitter flow (a group of up to four out-
put channels) to a receiver flow (a group of
up to four input channels).
The Model 5401A uses a Brooklyn II mod-
ule to implement its Dante functionality. The
number of transmitter flows associated with
this module is 32 and, as such, typically
no flow limitation should occur. These flows
can either be unicast, multicast, or a combi-
nation of the two. Note, however, that when
AES67 mode is enabled in Dante Controller
the Dante transmitter (output) channels will
only function in multicast; unicast is not
supported.
Unit and Channel Names
The Model 5401A has a default Dante
device name of ST-5401A- along with a
unique suffix. The suffix identifies the spe-
cific Model 5401A that is being configured.
The suffix’s actual alpha and/or numeric
characters relate to the MAC address of the
unit’s Brooklyn II module. The eight Dante
transmitter (output) channels associated
with the tone outputs have default names
of Tone 1 through Tone 8. Using Dante
Controller, the device and channel names
can be revised as appropriate for a specific
application.
Device Configuration
The Model 5401A supports audio sample
rates of 44.1, 48, 88.2, 96, 176.4, and 192
kHz with no pull-up/down options available.
The digital audio data is in the form of 24-bit
pulse-code modulation (PCM 24) samples.
Clocking- and latency-related parameters
can be adjusted if required in Dante Control-
ler but the default values are typically correct.
Network Configuration –
Dante
As has been covered previously in this guide,
the Model 5401A allows connection of one,
two, or three Ethernet signals using standard
RJ45 jacks which are located on the back
panel. In many applications, two of the jacks
will be used for Dante audio and the third
for connecting to a network designated for
device management purposes. It’s also pos-
sible to access the Model 5401A’s manage-
ment webpages using the Dante Ethernet
ports. The Model 5401A’s Dante ports are
labeled PRI and SEC indicating that they are
typically used for the primary and secondary
connections. The third Ethernet port is la-
beled MGMT, indicating that it is intended for
use accessing the management webpages.
How these three Ethernet ports function can
be selected in the Network Config – Switch
Configuration section of Dante Control-
ler. The choices are Switched, Redundant,
Switched+Mgmt, and Redundant+Mgmt.
If Switched is selected then the Model 5401A
can establish one Dante audio connection
with an Ethernet network. It doesn’t matter
which RJ45 jack is utilized, although for clar-
ity this would typically be the primary jack.
The secondary RJ45 jack can be used to
interconnect with another piece of networked
equipment. The management Ethernet port
will be used to access the management
webpages.
Issue 2, July 2021
Model 5401A User Guide
Page 14
Studio Technologies, Inc.
If the Model 5401A’s Dante network is con-
figured for Switched ensure that only one
of the two Dante RJ45 jacks on the back
panel is connected to the LAN associated
with the Dante network. If both of the Model
5401A’s Dante RJ45 jacks are routed to
ports on the same LAN this will typically
“crash” the network! (Although some of the
latest/most-advanced Ethernet switches
will automatically detect and prevent such
a “network bridging” issue from occurring.)
If Switched+Mgmt is selected the same
issues as discussed in the previous two
paragraphs would again apply. The only
difference is that the management web-
pages would be accessed using the same
Dante Ethernet port that is being used to
access the Dante network. The manage-
ment Ethernet port will be disabled.
If Redundant is selected then Dante’s
Redundant networking capability will be
enabled. In this case, separate Ethernet
LAN connections should be made to the
Dante primary and Dante secondary RJ45
jacks. Again, the Model 5401A’s separate
management Ethernet port will be used to
access the management webpages.
If Redundant+Mgmt is selected in Dante
Controller then the network connection
made to the Dante primary Ethernet port
will also be used to access the manage-
ment web-pages. The Model 5401A’s sepa-
rate management port will be disabled.
IP Addresses
When a Model 5401A has been configured
for either the Switched or Switched+Mgmt
network mode a single Dante IP address
will be associated with the network connec-
tion that is made to either the Dante primary
or the Dante secondary RJ45 jack. If the
network configuration has been selected
for Redundant or Redundant+Mgmt then
separate IP addresses and related network
parameters will be assigned to the Dante
primary and Dante secondary Ethernet
ports. No matter what network mode has
been selected the Model 5401A will always
have a separate management IP address.
Typically, the Model 5401A’s Dante IP
address or addresses and related network
parameters will be determined automati-
cally using DHCP or, if that’s not available,
the link-local network protocol. If desired,
the Dante Controller application does allow
Dante IP addresses and related network
parameters to be manually set to a fixed
(static) configuration. While this is a more-
involved process than simply letting DHCP
or link-local “do their thing,” if fixed address-
ing is necessary then this capability is
available.
Note that if the Model 5401A’s network
configuration has been set for Redundant
or Redundant+Mgmt then the Dante prima-
ry and Dante secondary IP addresses and
related parameters can be independently
configured. This allows both Dante inter-
faces to be configured automatically, both
interfaces to be configured manually, or one
interface to be configured automatically and
the other to be configured manually.
By default, the Model 5401A’s management
IP address and related network parameters
will be determined automatically using
DHCP or link-local. A configuration option,
accessible using the front-panel display
and associated buttons or the management
webpages, allows manual control of the
management IP address, subnet mask, and
gateway address values.
AES67 Configuration –
AES67 Mode
Dante Controller allows a Model 5401A to
be configured for AES67 operation. This
requires the AES67 mode to be set for
Enabled. As previously noted in this guide,
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 15
if AES67 mode is enabled then PTPv2 will
be utilized and the Dante transmitter (out-
put) channels will use multicast. The sam-
ple rate will be fixed at 48 kHz.
Preferred Clock Source
By the very nature of its intended applica-
tion, the Model 5401A will normally serve
as the Leader Clock for all Dante-enabled
devices. The unit has the ability to com-
municate with the Dante network, selecting
itself as the Preferred Leader and causing
the Enabled Sync to External function to
be enabled. The status of these two pa-
rameters can be observed using the Clock
Status function in Dante Controller.
Settings accessible using the Model
5401A’s management webpages allow ex-
tensive changes to the clock configuration.
These are provided for use when trouble-
shooting or addressing special applications.
In most cases, the Model 5401A’s default
settings would be appropriate and should
be utilized.
Model 5401A
Configuration
Many Model 5401A Dante Leader Clock
operating parameters can be configured
using the management system’s webpages
that are provided by way of one of the unit’s
Ethernet ports. The specific port utilized for
management will depend on the network
configuration that is selected using the
Dante Controller application. A standard
web browser is all that is required to utilize
the menu webpages.
Several key network configuration param-
eters can also be viewed and revised using
the Model 5401A’s front-panel graphics dis-
play and associated pushbutton switches.
Refer to Appendix D for details on which
parameters can be revised in this manner.
Management IP Address
It’s easy to identify the Model 5401A’s man-
agement IP address by way of the front-
panel display. If the screen saver function
is active, as it will be in most situations,
one of the five pages that will automatically
display will show the current management
IP address. As such, a user can simply
observe the sequencing menu pages and
watch for the one that displays the cur-
rent management IP address. If it’s desired
that the current management IP address
be continuously displayed then the Enter
pushbutton switch on the front panel should
be pressed. This will stop the screen saver
function and cause the current manage-
ment IP address to display. It will also allow
the various menu pages to be accessed
using the up, down, left, and right pushbut-
ton switches. Simultaneously pressing the
left and right arrow buttons will cause the
screen saver mode to begin again. The
screen saver mode will also automatically
start two minutes after the last press of any
of the front-panel pushbutton switches.
How the management Ethernet port obtains
its IP address will depend on the manage-
ment interface configuration setting. The
default method is automatic so the Model
5401A’s management port will first try to
obtain an IP address using DHCP. If that
is not successful an IP address will be
assigned using the link-local protocol. An
address of 169.254.x.x will indicate that an
IPv4 address was established using link-lo-
cal. The Model 5401A may also have been
configured to use a manual (fixed or static)
IP address. The front-panel display and as-
sociated pushbuttons, or the Model 5401A’s
management webpages, can be used to re-
view and/or make changes to the manage-
ment IP address and related parameters.
Issue 2, July 2021
Model 5401A User Guide
Page 16
Studio Technologies, Inc.
Accessing the Management
Webpages
To access the Model 5401A’s home web-
page, type the unit’s management IP ad-
dress into a browser’s search bar. (It’s
possible that some browsers may require
including the text http:// followed by the IP
address.) Of course, the computer associ-
ated with the browser must be on the same
LAN and subnet as the Model 5401A.
Home Menu
Once the Model 5401A menu system has
been accessed the Home webpage will ap-
pear. It provides six display-only fields along
with a link to the Login menu webpage. The
fields are similar to those provided in the
Main menu configuration webpage. The
current clock source field will display which
timing source is actively being utilized by
the Model 5401A. The Sync Input status
field displays the current operating condi-
tion of the sync input whose BNC jack is
located on the unit’s back panel. The four
Dante sync status fields will display the role
that the Model 5401A is actively playing as
PTPv1 and PTPv2 timing resources for the
devices connected to the associated net-
work or networks. Details about these fields
are provided in the Main menu paragraphs
found later in this section.
Login Menu
From the Home webpage click on the Login
tab to access the Login webpage. Entry of
a valid user name and password is required
to access the additional configuration
menus. The Model 5401A doesn’t incorpo-
rate a sophisticated security implementa-
tion. The User name and password, as well
as the underlying software, is intended to
keep “honest” people from making unau-
thorized changes to the configuration of the
Model 5401A. It is not intended as a sophis-
ticated, rigorous security system.
Should the applicable user name and/or
password be misplaced, refer to the Techni-
cal Notes section and/or Appendix H of this
guide for a recovery method.
User Name: Enter the Model 5401A’s user
name into this field. It is case sensitive.
The default user name is guest. If both the
default user name and the default password
are active then the user name will display in
this field.
Password: Enter the Model 5401A’s pass-
word into this field. It is case sensitive. The
default password is guest. If both the default
user name and the default password are
active then the password will display in this
field.
Log In Button: Click on the Log In button
to submit the entered user name and pass-
word. If the correct entries have been made
the Main menu webpage will display. If an
incorrect user name and/or password is
entered then a login failed message will be
displayed.
Main Menu
Once the correct user name and password
have been submitted the Main menu web-
page will be displayed. This menu provides
the ability to select three important operating
parameters as well as displaying seven key
real-time conditions. In addition, the menu
system allows direct access to other menu
webpages. Refer to Appendix E for a view of
the Main menu.
Main Clock Source: This is a configurable
field with three choices: Internal, Sync Input,
and Dante.
This setting determines which source will
be the main (normal) timing source that is
used by the Model 5401A’s circuitry as its
own “Leader” timing reference. This is the
clock source that will be used by the Model
5401A’s PTPv1 and PTPv2 servers that
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 17
are critical to the Model 5401A’s support
of related Dante devices. When Internal is
selected the Model 5401A’s temperature-sta-
bilized, high-performance crystal oscillator
is utilized. This will provide excellent timing
accuracy and consistent long-term perfor-
mance. This source is far superior to that
provided by other standard Dante devices.
This is the correct choice if a high-quality
reference signal is not going to be connected
to the sync input.
When Sync Input is selected the Model
5401A’s sync input function will be utilized.
Using a BNC jack, located on the Model
5401A’s back panel, an external source of
word clock, video reference, or 10 MHz sine
wave can be connected. Circuitry within the
Model 5401A will “lock” (synchronize) the
internal timing signals to the externally pro-
vided reference signal.
Selecting Dante will instruct the Model
5401A to use the clock signal provided by
its Dante interface circuitry as its reference
timing source. The Dante interface circuitry
will either use its internal crystal oscillator or
synchronize to another Dante device on the
associated network. The actual clock source
used by the Model 5401A’s Dante interface
will depend on a setting in the Dante Con-
troller application.
The Model 5401A includes the choice of
Dante as the main clock source only for trou-
ble-shooting or other factory-directed activi-
ties. It’s not expected that this selection will
ever be used during normal Model 5401A
operation. By selecting Dante the excellent
timing performance that can be provided by
the sync input or the internal oscillator would
not be utilized.
Failover Clock Source: This is a configu-
rable field with two choices: Internal and
Dante.
This configuration choice selects which tim-
ing source will be used should the Model
5401A’s selected main clock source be-
come unavailable. Specifically, the failover
source will be used if a valid sync source is
not connected to the sync input. If Internal
is selected then the unit’s crystal oscillator
will be utilized as the Leader clock source
should a valid sync input signal be unavail-
able. If Dante is selected then the failover
source will be the timing signal derived from
the Model 5401A’s Dante interface.
From a performance standpoint it’s prefer-
able to select Internal. This ensures that the
best clock performance can be obtained
should the failover condition be active.
However, selecting Dante would allow an
interesting, albeit obscure, alerting feature to
become active. In the Dante Controller ap-
plication, a device such as the Model 5401A
that has been selected as the Preferred
Leader with an external source allowed will
have an error condition occur if the Model
5401A’s Dante interface doesn’t detect an
external reference being applied. And los-
ing the external reference is what the Model
5401A’s circuitry will do should failover be
activated and Dante selected as the failover
source. In this way, a Dante network user
could be alerted to a clocking issue should
the Model 5401A lose its sync input source.
However, having an error condition reported
in the Dante Controller application is prob-
ably not terribly important. The Dante SYNC
LED, located on the Model 5401A’s front
panel, will also offer a clear indication of a
loss of an external sync input signal. This
LED will typically slowly flash green when
the Model 5401A is functioning correctly
as the Leader clock for the Dante network.
However, should the unit be configured to
use an external sync input signal and a valid
one is not present, the SYNC LED will flash
orange to indicate this loss of lock and that
the failover source is in use. In addition, the
display will provide a text indication of this
condition.
Issue 2, July 2021
Model 5401A User Guide
Page 18
Studio Technologies, Inc.
Force Preferred Leader: This is a configu-
rable field with two choices: Disabled and
Enabled.
This function impacts how the Model 5401A
will control a Dante network’s selection
of which device is going to serve as the
Leader clock. As the main reason for the
Model 5401A’s existence is to serve as a
Leader clock, in most applications the unit
should be serving in that role. By forcing the
Model 5401A to be a Preferred Leader clock
it helps to ensure optimal Dante network
operation. By enabling this configuration,
users of the Dante Controller application
will not be able to accidentally disable the
Model 5401A as a Preferred Leader. One
can observe exactly what is meant by the
term Force Preferred Leader by unchecking
the Model 5401A’s Preferred Leader check
box in Dante Controller. After a short inter-
val the box will automatically return to the
enabled (checked) state.
How the Model 5401A handles forcing the
Dante network to be a Preferred Leader
clock and, if applicable, automatically sup-
porting an external clock input is not trivial.
This ability to control Dante network opera-
tion is part of the unit’s “secret sauce.” If the
Model 5401A’s clock source is configured
for Dante then the Model 5401A will force
off (uncheck) the Enable Sync to External
selection in Dante Controller. If the Model
5401A’s main clock source is configured for
Internal or Sync Input then the Model 5401A
will force on (check) the Enable Sync to
External configuration in Dante Controller.
This will apply as long as this specific Model
5401A is acting as Primary Leader, Leader,
or AES67 Leader.
Submit: A Submit button is located below
the Force Preferred Leader field. For any
changes made to the three configurable
fields on the Main menu webpage to be
saved and acted upon the Submit button
must be pressed.
Current Clock Source: This is a display-
only field with choices of Internal, Internal
(Failover Active), Sync Input, Dante, and
Dante (Failover Active).
The text Failover Active will display in red
as a warning of an abnormal condition that
warrants intervention. The current clock
source field can also display --- which in-
dicates a major hardware error and would
warrant contacting the factory.
When Internal is displayed it indicates that
the Model 5401A’s internal temperature-
stabilized oscillator is being used as its
timing reference. When Internal (Failover
Active) is displayed an abnormal condition
is occurring. In this case, the Model 5401A
has been configured to use an external
sync signal as the main clock source but
a valid one is not available; it is using its
internal temperature-stabilized oscillator as
the failover timing reference. If Sync Input
is displayed this indicates that an external
timing reference signal is connected to the
sync input BNC jack on the Model 5401A’s
back panel and it is being used as the main
clock source. If Dante is displayed this indi-
cates that the Model 5401A is using a timing
reference derived from its Dante network
interface. This is not an invalid condition but
would typically only occur in a troubleshoot-
ing situation. If Dante (Failover Active) is
displayed an abnormal condition is occur-
ring. In this case, the Model 5401A is using
a timing reference derived from its Dante
network interface. However, this is only oc-
curring because the configured main clock
source is not currently available.
Sync Input Status: This is a display-
only field with choices of Locked (Active),
Locked (Standby), Unlocked, and Idle. As
a warning of an abnormal condition the text
Unlocked will display in the color red.
If Locked (Active) is displayed this indicates
that a valid signal is connected to the Model
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 19
5401A’s sync input and is serving as the
unit’s timing reference. If Locked (Standby)
is displayed this indicates that a valid sig-
nal is connected to the Model 5401A’s sync
input and while it is capable of serving as
the unit’s main timing reference it is not cur-
rently serving as the main clock source.
If Unlocked is displayed it can be the re-
sult of several conditions. It can display if
a signal is connected to the Model 5401A’s
sync input but is not being recognized as
a valid timing reference. This can occur for
multiple reasons. The most common would
be due to a configuration mismatch, such as
if a video reference is connected while the
Model 5401A’s sync input is configured to
support a word clock source. It might also
indicate that a non-supported word clock
rate or an incompatible video reference is
connected. Unlocked could also be dis-
played if no signal is connected to the sync
input or if a connected signal is incorrectly
terminated, e.g., no termination applied
when one is required or if two terminations
(“a double termination”) were present.
Idle will display if the sync input has not
been selected as the Model 5401A’s main
clock source and a valid source has not
been connected to the sync input. It simply
indicates that the sync input circuitry is not
actively receiving an external signal.
Primary Leader Clock: A display-only field
will show the MAC (media access control)
address of the Dante network’s currently
active Primary Leader Clock. Displayed to
the right of the MAC address will be an ad-
ditional piece of information about what spe-
cific device is associated with the displayed
MAC address. If the MAC address is asso-
ciated with this specific Model 5401A then
the text will show (This Device). If the MAC
address is not for this specific Model 5401A
the text will show (Other Device).
A logical question to ask would be “so what
is this Other Device?” Unfortunately, the
Model 5401A’s firmware does not have
the ability to know more about a specific
Primary Leader Clock other than its MAC
address. It can only determine if the MAC
address matches this specific Model 5401A
or not. If the address doesn’t match then
another device has to be serving as the
Primary Leader. The Dante Controller may
provide more detailed information about a
Dante network’s clocking. And network soft-
ware or hardware tools may allow a MAC
address to be associated with a specific
device.
Note that the information provided in this
field can be a bit confusing, even to the
writer of this guide. But for a network maven
it can be very useful when troubleshooting
a complex network timing issue. Reviewing
several related issues to Primary Leader
Clock can be valuable. First of all, it’s impor-
tant to note that the reference to the word
primary in “Primary Leader Clock” has noth-
ing to do with the primary and secondary
Ethernet interfaces! In this context Primary
Leader Clock refers to the device that all
other devices in a Dante network will follow.
In most cases, a Model 5401A will serve
as the Primary Leader Clock. But there is
no requirement that it must play this role.
For example, a Model 5401A can serve as
a Leader Clock while following the timing
provided by another device that’s serving
as the Primary Leader Clock. For another
example, one Model 5401A could serve as
the Primary Leader Clock while several oth-
er Model 5401A units serve as PTP bound-
ary clocks. These boundary clocks would,
by way of a unicast PTP message, synchro-
nize with the Primary Leader Clock. The
boundary clocks could then provide PTPv1
and PTPv2 functionality (using multicast)
with timing based on that derived from the
Primary Leader Clock. This method may be
Issue 2, July 2021
Model 5401A User Guide
Page 20
Studio Technologies, Inc.
used to provide Dante device timing across
different subnets for complex or especially
large applications. For more in-depth control
of these clocking issues the Dante Domain
Manager (DDM) software application can be
very useful.
Dante Sync Status: The Model 5401A can
simultaneously serve as a Leader clock for
both Dante primary and Dante secondary
networks and is capable of supporting both
PTPv1 (IEEE 1588-2002) and PTPv2 (IEEE
1588-2008). As such the unit is capable of
acting as four independent Leader clocks:
PTPv1 for Dante primary, PTPv2 for Dante
primary, PTPv1 for Dante secondary, and
PTPv2 for Dante secondary. While the
PTP processes are asymmetrical, they do
share the same internal timing reference.
The Model 5401A can also act as a PTPv1
and PTPv2 clock follower but that would
typically be utilized only for test purposes.
Standard and Redundant Dante (no AES67
support) uses PTPv1 and that is always
enabled in the Model 5401A. AES67 utilizes
PTPv2 clocking and if support for AES67
is desired within the Dante environment it
must be enabled using a configuration set-
ting in the Dante Controller application.
The Model 5401A’s Main menu has four
fields that display the real-time sync sta-
tus of the PTPv1 and PTPv2 functions for
the Dante primary and Dante secondary
interfaces. If the network configuration in
Dante Controller for this specific Model
5401A has been selected for Switched or
Switched+Mgmt the clocking status of the
Dante primary interface will be displayed.
In this situation, the Dante primary PTPv1
interface will show Leader, Follower, Link
Down, or Error (with the latter showing in
red text). If AES67 support is enabled in
Dante Controller then the same choices
will also be displayed in the primary PTPv2
field. If AES67 support is not enabled then
Disabled will show in the primary PTPv2
field. Since Dante secondary is not enabled
then the secondary PTPv1 and secondary
PTPv2 fields will show Disabled.
If the Model 5401A’s network configura-
tion has been selected for Redundant or
Redundant+Mgmt then both the primary
PTPv1 and secondary PTPv1 sync sta-
tus fields will display their respective sync
status. They will show the same choices
as described above: Leader, Follower, Link
Down, or Error (with the latter showing in
red text). If AES67 support is enabled in
Dante Controller then the same choices will
also be displayed in the primary PTPv2 and
secondary PTPv2 fields. If AES67 support is
not enabled then Disabled will show in both
the primary PTPv2 and secondary PTPv2
fields.
Should Leader be displayed in a specific
field it would indicates that this specific
Model 5401A is acting as the Leader clock
for the Dante network and clock function
associated with that field. If Follower is dis-
played this indicates that this specific Model
5401A is obtaining its timing reference from
another Dante device on the network. This
would be the current display if this specific
Model 5401A was serving as a “hot” stand-
by Dante Leader clock.
If Link Down is displayed this will indicate
that a valid Ethernet connection has not
been made to the RJ45 jack associated with
that field’s Model 5401A’s Ethernet inter-
face. A display of Error would indicate that
this specific Model 5401A is having a per-
manent or temporary issue with its internal
circuitry. There may be occasions where
Error would display for a few seconds while
Model 5401A circuitry first becomes active.
Sync Input Menu
The Sync Input menu has parameters that
are related to the Model 5401A’s sync input.
This allows an external source of timing to
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 21
be connected to the Model 5401A by way of
a BNC jack that is located on the unit’s back
panel. Refer to Appendix E for a view of the
Sync Input menu.
Lock Status: This is a display-only field
that can show Unlocked, Locked followed
by one of the word clock rates, Locked fol-
lowed by one of the video rates, or Locked
(10 MHz). It’s also possible that it could
display Error which would indicate a Model
5401A hardware problem. This would be a
rare occurrence and, in this case, contact-
ing the factory would be recommended.
This field reflects the operation of the Model
5401A’s sync input circuitry. Unlocked will
display if no signal source is connected
or if the connected source doesn’t match
the selected sync input type. For example,
Unlocked will display if Word Clock has
been selected as the sync input type but
a video sync signal has been connected.
The detected rate will be displayed follow-
ing the term Locked whenever the sync
input is locked to the connected signal. If
this is a word clock signal then one of the
six compatible rates will be displayed: 44.1,
48, 88.2, 96, 176.4, or 192 kHz. If Locked
displays due to a video source being con-
nected then the actual rate/format charac-
teristics will also be displayed. If the sync
input is locked due to a 10 MHz signal being
recognized then Locked (10 MHz) will dis-
play. The compatible sync input sources are
listed in Appendix A of this guide.
Unlocked will be displayed, in the text color
red, if the sync input has been selected on
the Main menu as the Model 5401A’s clock
source but either no signal is connected to
the sync input or a non-compatible signal is
connected. A non-compatible signal would
include a sync input type being selected for
Word Clock and then a word clock signal
at a different rate than the current Dante
sample rate is connected. For example, an
incompatible situation would be where the
current Dante sample rate is 48 kHz but
the connected word clock signal is 96 kHz.
Probably the most common non-compatible
signal would be a situation where a video
reference signal is connected to the sync
input but the sync input type was left at the
default (Word Clock) rather than being se-
lected for Video.
Current Dante Sample Rate: This is a
display-only field that can show 44.1 kHz,
48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz, or
192 kHz. It can also display Error in the
unlikely event that there is an issue with the
Brooklyn II module that provides the Model
5401A’s Dante interface.
This field displays the Model 5401A’s cur-
rently selected sample rate as used by the
Model 5401A’s Dante transmitter (output)
channels. The Dante transmitter (output)
channels provide eight sine wave tone
labeled Tone 1 through Tone 8. Changes to
the Dante sample rate are made using the
Dante Controller software application.
Type: This is a configurable field with three
choices: Word Clock, Video, or 10 MHz.
If the Model 5401A’s clock source has been
selected to Sync Input on the Main menu
the type of connected source must be de-
fined to match the application. If Word Clock
is selected then a square wave source with
a rate of 44.1, 48, 88.2, 96, 176.4, or 192
kHz needs to be connected. For proper
operation the nominal unloaded level of the
word clock source must be 5 volts DC peak-
to-peak. Also, the connected word clock
source must match the displayed current
Dante sample rate. This is a bit of a “chick-
en or the egg” situation since it can be con-
fusing as to who is supposed to control the
sample rate and who is supposed to follow
the sample rate! The Dante Controller soft-
ware application should be used to select
the desired Model 5401A sample rate. This
Issue 2, July 2021
Model 5401A User Guide
Page 22
Studio Technologies, Inc.
is the sample rate desired for the sine wave
audio channels provided by the tone gen-
erator function. In most applications this will
be 48 kHz. It’s possible that in some audio-
only applications 96 kHz or even 192 kHz
will be selected. Once the desired sample
rate has been selected and/or confirmed,
an external word clock source of the same
rate should be connected. If the available
external word clock source has a rate differ-
ent than the current Dante sample rate then
a review of the entire application must be
performed and a common rate selected.
If Video is selected for the sync input type
then a wide range of bi- and tri-level video
reference signals can be connected to the
sync input BNC jack. The Model 5401A’s
circuitry will automatically decode many of
the most common format/rate combinations.
These include ubiquitous “black burst” sig-
nals as well as signals intended to support
4K video applications. Refer to Appendix A
at the end of this guide for a detailed list of
compatible video sources.
If 10 MHz is selected then the sync input is
expecting connection of a sinusoidal source
of 10 MHz. A signal of this type is typically
associated with industrial or instrumentation
applications. It may also be provided by a
GPS (satellite) receiver.
If a choice of sync sources is available for a
specific application it’s recommended that
a source of word clock be utilized. This is
not because a word clock source is inher-
ently better, but rather the recommendation
is related to the Model 5401A’s circuit de-
sign. The unit’s logic circuitry has to per-
form the least amount of processing with a
word clock input signal as compared to that
required to utilize a video reference or a 10
MHz signal. All compatible signals will work
well but using a source of word clock re-
quires the least logic “horsepower.”
Termination: This is a configurable field
with two choices: Off and On.
If desired, the Model 5401A can apply a
terminating impedance to the sync input
connection. The need for an input source
to be terminated, or not, will depend on the
source of the external sync signal. Typically,
a source of sync should have one (and only
one) termination applied. A timing reference
source can generally be shared (“bused”) to
multiple devices with only the last connec-
tion on the “string” having an appropriate
termination.
If the sync input termination is configured
for Off then the sync input’s impedance will
be considered “high Z.” If the sync input
termination is selected to On and the sync
input type is selected for Word Clock or
Video the termination impedance will be 75
ohms. If 10 MHz has been selected as the
sync input type then a termination imped-
ance of 50 ohms will be applied.
These termination values were selected to
meet the technical requirements of indus-
try-standard reference signals. Word clock
should be a square wave with a source
impedance of 75 ohms. Video is typically a
complex analog signal with a source imped-
ance of 75 ohms. And a 10 MHz reference
is a normally a sine wave with a source
impedance of 50 ohms.
Submit: A Submit button is located on the
bottom of the Sync Input menu webpage.
To save any changes made to fields on the
Sync Input webpage requires that the Sub-
mit button be pressed. The Model 5401A
will immediately incorporate operating
changes as soon as the Submit button has
been pressed.
Tone Generator Menu
The Model 5401A’s tone generator function
is capable of creating eight precision sine
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 23
wave tones with independent frequency and
level configuration. The frequency range is
1 to 22000 hertz (Hz) and the level range
is –99 to 0 dBFS. Refer to Appendix E for a
view of the Tone Generator menu.
The tone signals have Dante transmitter (out-
put) default names of Tone 1 through Tone 8.
It’s expected that most applications will only
use a few of the tones. But having eight out-
put channels provides flexibility in creating a
set of tones with various frequency and level
combinations. These can be useful in a range
of applications including identifying individual
channels in a multi-channel arrangement,
e.g., stereo, 5.1, or 7.1.
Frequency (Hz): These eight fields reflect
the Model 5401A’s currently selected sine
wave tone generator frequencies. For each
channel enter the desired frequency in full
hertz. Don’t use a suffix such as k or kHz, nor
enter a comma or period to delineate thou-
sands. Entering 1001 would be correct while
1,001 or 1.001 k would not be acceptable.
The default tone frequencies were selected
in hundreds of hertz with the first digit match-
ing the channel number: 100, 200, 300, etc.
This can be useful when checking a series of
channels as this pattern can be easily recog-
nized either by ear or using equipment that
can display the frequency in text. Some ap-
plications may need the common 1000
or 10000 Hz reference sine wave tones
and there’s no problem configuring these
if desired.
Level (dBFS): These eight fields display
the level of the Model 5401A’s sine wave
tone outputs. The output level for each of
the audio output channels is independently
adjustable over a range of –99 to 0 dBFS.
The level is selectable in 1-dBFS steps.
Enter the desired level in full dBFS with a
hyphen as the prefix to indicate less than full
scale. In applications that comply with the
SMPTE® audio standards the typical nominal
level will be –20 dBFS which can be thought
of as 20 dB less than full scale or digital
0. In EBU applications the typical nominal
level will be –18 dBFS. Some applications
may benefit from a sine wave test tone
that’s 12 dB less than the reference level.
This would equate to configuring an output
to –34 dBFS (SMPTE) or –32 dBFS (EBU).
These would typically be associated with a
1000 Hz tone.
The default tone levels were selected in a
pattern that could help identify a specific
channel. Dante transmitter (output) channel
Tone 1 has a default level of –21 dBFS with
the value of 1 being selected to reflect the
channel number. Each subsequent chan-
nel then reduces its level by 1 dB. So, for
example, the second channel, Tone 2, has
a level of –22 dBFS. While these level steps
may not be readily discernible to human
ears most test equipment or metering could
easily be used to identify specific channels.
Submit: A Submit button is located at the
bottom of the Level (dBFS) column on the
Tone Generator menu webpage. To save
any changes made to the level or frequency
fields requires that the Submit button be
pressed. Changes will be made immediately
after pressing the Submit button.
Network Menu
Refer to Appendix E for a view of the
Network menu.
Interfaces
There are twelve display-only fields that
relate to the key parameters that are associ-
ated with the Dante and management inter-
faces. For clarity they display in the form of
a simple table.
IP Addresses: These three display-only
fields will show the current IP addresses
associated with the Model 5401A’s Dante
primary, Dante secondary, and manage-
Issue 2, July 2021
Model 5401A User Guide
Page 24
Studio Technologies, Inc.
ment ports. The Dante primary and manage-
ment fields will show either Link Down or an
IP address. The Dante secondary field will
show Disabled, Link Down, or an IP address.
Link down will display if an Ethernet connec-
tion has not been made to the appropriate
RJ45 jack on the Model 5401A’s back panel.
Disabled will show if Dante redundancy has
not been enabled in the Dante Controller
application. The 32-bit IP v4 addresses will
be displayed in what’s known as dot-decimal
notation (4 octets, each separated by a dot).
How the IP addresses are assigned will de-
pend on the Model 5401A’s network configu-
ration setting as performed using the Dante
Controller application. Each IP address can
be established automatically using a DHCP
server or the IPv4 link-local protocol. An
IP address assigned to the Dante primary
interface by link-local will have a format
of 169.254.x.x. An IP address assigned to
the Dante secondary interface by link-local
will have a format of 172.31.x.x. The Dante
primary and secondary IP addresses can
also be individually set to a manual (static or
fixed) IP addresses using the Dante Control-
ler application.
If the network configuration is selected for
switched the Dante primary IP address
will be associated with a network connec-
tion made to either the Dante primary or
Dante secondary RJ45 jacks on the Model
5401A’s back panel. Link down will display
if no connection is present. The IP address
for the Dante secondary interface will show
disabled as it is not being utilized in this
network mode. The management IP address
will be associated with a network connection
made to the management RJ45 jack on the
Model 5401A’s back panel.
If the network configuration is selected for
Redundant then the Dante primary IP ad-
dress will be associated with the RJ45 jack
labeled PRI on the Model 5401A’s back
panel. Link Down will display if a valid
Ethernet connection has not been made to
the Dante primary Ethernet interface. The
Dante secondary IP address will be associ-
ated with the RJ45 jack labeled SEC on the
Model 5401A’s back panel. Link Down will
display if a valid Ethernet connection has not
been made with the Dante secondary Ether-
net interface. The management IP address
with be associated with a network connec-
tion made to the RJ45 jack labeled MGMT
on the Model 5401A’s back panel.
If the network configuration is selected in
Dante Controller for Switched+Mgmt then
the Dante primary IP address will be asso-
ciated with a network connection made to
either the Dante primary or the Dante sec-
ondary RJ45 jacks on the Model 5401A’s
back panel. The IP address field for the
Dante secondary interface will show Dis-
abled as it is not be utilized. The manage-
ment IP address will be associated with a
network connection made to either the Dante
primary or Dante secondary RJ45 jacks
If the network configuration is selected for
Redundant+Mgmt then the Dante primary
IP address will be associated with a connec-
tion made to the RJ45 jack labeled PRI on
the Model 5401A’s back panel. Link Down
will display if a valid Ethernet connection has
not been made. The Dante secondary IP
address will be associated with an Ethernet
connection made to the RJ45 jack labeled
SEC on the Model 5401A’s back panel. Link
Down will display if a valid Ethernet connec-
tion has not been made with the Dante sec-
ondary Ethernet interface. The management
IP address with be associated with a net-
work connection made to the Dante primary
RJ45 jack located on the Model 5401A’s
back panel.
If the Model 5401A’s network configuration
in Dante Controller is selected for Switched
or Switched+Mgmt ensure that only one of
the RJ45 jacks on the back panel is con-
nected to the LAN associated with the Dante
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 25
devices. The other RJ45 jack can be used
to interconnect with another piece of net-
worked equipment. But having both the
Model 5401A’s Dante primary and Dante
secondary RJ45 jack routed to ports on the
same LAN will typically “crash” the network!
Subnet Mask Values: These three fields
will show the subnet mask values associ-
ated with the Dante primary, Dante second-
ary, and management ports. They will show
either Link Down or a subnet mask value.
The subnet mask value will be displayed in
dot-decimal notation. When the IP address
of the Dante primary or Dante secondary
interfaces have been obtained using link-
local the subnet mask value will always be
255.255.0.0.
Gateway Addresses: These three fields
will show the gateway address associated
with the Dante primary, Dante secondary,
and management ports. They will show
either Link Down, ---, or a value in dot-deci-
mal notion. A gateway address is usually
obtained using DHCP or by way of a fixed
(or static) stored value. When an IP address
has been obtained using link-local then
there will be no gateway address and --- will
display. A Dante interface will typically only
use a gateway address as a means of ac-
cessing an update server that’s is located
outside of the Dante network’s LAN.
MAC Addresses: Three display-only fields
will show the MAC (media access control)
addresses associated with the network in-
terface controller (NIC) devices used for the
Dante primary, Dante secondary, and man-
agement ports. These are fixed hardware
addresses assigned to Ethernet ports. Each
is unique among all Ethernet ports and can-
not be changed. The Model 5401A displays
MAC addresses as six groups of two hexa-
decimal digits, separated by hyphens. No
MAC address will be displayed if an Ether-
net interface has been disabled.
Switch Configuration: This is a display-
only field that shows the Model 5401A’s
network configuration as determined by
a setting in the Dante Controller applica-
tion. The term “Switch” refers to an Eth-
ernet switching and routing integrated
circuit that is part of the Model 5401A’s
hardware. How this integrated circuit is
configured determines the how the Model
5401A’s three GigE Ethernet ports function.
The field will show Switched, Redundant,
Switched+Mgmt, or Redundant+Mgmt. It
will also display Error in the unlikely event
that an error in the Dante interface circuit,
provided by a Brooklyn II module, has
occurred.
Management Interface
Configuration
There are four fields that relate to the Model
5401A’s management interface. They don’t
have any relation to the Dante primary and
Dante secondary IP addresses and their
associated network parameters.
IP Address Configuration: This is a con-
figurable field with two choices: Automatic
and Manual.
The selected configuration impacts how the
Model 5401A obtains the IP address that is
used for accessing the Model 5401A’s man-
agement web server and associated menu
webpages. This setting has no impact on
how the Model 5401A obtains IP addresses
for the primary and secondary Dante IP
interfaces.
Selecting the Automatic setting causes the
Model 5401A to use the DHCP or, if DHCP
is not available, the IPv4 link-local protocol
to establish the IP address for the Model
5401A’s management port. When selected
to use Automatic, upon establishing a con-
nection to the configured Model 5401A
RJ45 jack the DHCP protocol will request
an IP address and related parameters. If
Issue 2, July 2021
Model 5401A User Guide
Page 26
Studio Technologies, Inc.
obtaining an IP address in this manner is
not successful then the IPv4 link-local proto-
col will be used. (If an IP address has the
format of 169.254.x.x then it was assigned
using IPv4 link-local.) Even if the IP ad-
dress was established using link-local the
DHCP protocol will remain active. In this
case, approximately every 30 seconds the
Model 5401A’s firmware will check for the
presence of a DHCP server. If one be-
comes available then an IP address will be
requested and, when obtained, will auto-
matically replace the IP address that was
previously established by link-local.
The Manual setting allows the desired
IP address and related parameters to be
manually entered. This can be useful when
a fixed addressing scheme has been estab-
lished. In this way, a static IP address can
be entered along with the other important
network parameters.
When selected for Automatic the fields for
the manual IP address, subnet mask value,
and gateway IP address will be “grayed
out” (will have a gray background) to indi-
cate that their values cannot be manually
changed. In this condition they are display-
only. Changing between Automatic and
Manual and vice-versa will not impact the
values stored in the manual IP address,
manual subnet mask value, and manual
gateway IP address fields.
Note that to minimize the chance of los-
ing access to the management web server,
restoring the Model 5401A’s default configu-
ration values will not change the currently
selected IP address configuration choice.
Manual IP Address: This field shows the
stored IP address associated with the
management web server when the manual
mode has been selected for the IP address
configuration. This address has nothing to
do with the IP address utilized by the prima-
ry and secondary Dante ports. When IP
address configuration is selected for Auto-
matic this field is grayed out and the value
cannot be revised. Whenever the IP ad-
dress configuration is selected for Manual
the manual IP address can be modified as
desired to meet the requirements of the
application. After entering an IP address,
using the standard dot-decimal notation, the
Submit button at the bottom of the webpage
must be pressed for the changes to be
stored. A system reboot is required for the
revised manual IP address to be utilized.
The Reboot function is available on the sys-
tem webpage and the front panel. Restoring
the Model 5401A to its default values will
not change the stored manual IP address.
Manual Subnet Mask Value: This field
shows the stored subnet mask value as-
sociated with the management web server
when the manual mode has been selected
for the IP address configuration. When IP
address configuration is selected for Auto-
matic this field is grayed out and the value
cannot be revised. When the IP address
configuration is selected for Manual this
field will not be grayed out and the value
can be modified as desired to meet the
requirements of the application. After en-
tering a revised subnet mask value, using
the standard dot-decimal notation format,
the Submit button must be pressed for the
change to be stored. A system reboot is
required for the revised subnet mask value
to be utilized. Restoring the Model 5401A’s
default values will not change the stored
manual subnet mask value.
Manual Gateway: This field shows the
stored gateway value associated with the
management web server when the manual
mode has been selected for the IP address
configuration. When IP address configura-
tion is selected for Automatic the manual
gateway field is grayed out and the value
cannot be revised. When the IP address
configuration is selected for Manual this
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 27
field will not be grayed out and the value
can be modified as desired. After enter-
ing a revised gateway value, using dot-
decimal notation, the Submit button must
be pressed for the change to be stored. A
system reboot is required for the revised
gateway value to be utilized. Restoring
the Model 5401A’s default values will not
change the stored manual gateway value.
Submit: The Submit button is located at the
bottom of the Management Interface area
of the Network menu webpage. To save any
changes made to four fields in the Manage-
ment Interface requires that the Submit
button be pressed. To utilize those changes
requires that a Model 5401A reboot to take
place. That can occur by using the system
Reboot function on the system webpage or
a selection on the front panel’s menus.
Access Menu
As a security method a user name and
password must be entered before the con-
figuration webpages can be accessed. (This
is what you did to get this far!) These values
can be changed as desired. Refer to Appen-
dix E for a view of the Access menu.
The Model 5401A’s access security method
is in no way rigorous. The user name and
password are sent to and received from
the Model 5401A as plain text. They are
also stored within the Model 5401A as plain
text. There is no security method or encryp-
tion associated with these fields. Anyone
“snooping” on the LAN that is transporting
Model 5401A management data will see all
values in plain text. The ability to select user
name and password values is intended sim-
ply to provide a means of keeping “honest”
users from easily changing the configuration
of a Model 5401A. If unauthorized access
is of concern then it’s recommended that
the Model 5401A’s network configuration be
selected for Switched or Redundant. And
then an Ethernet connection to the Model
5401A’s management RJ45 jack should not
be present except when access by autho-
rized personnel is desired.
The default user name is guest and the
default password is guest. These are case
sensitive. If neither of the default entries
are changed then they will display in the
user name and password entry fields on the
Login menu webpage. If the default user
name and/or default password is changed
then neither the user name nor the pass-
word will display upon accessing the Login
menu webpage.
Management Log Credentials
User Name: In this field a revised user
name can be entered. The user name must
be a minimum of five characters, a maxi-
mum of 15 characters, and is case sensi-
tive. All 95 of the printable ASCII characters
can be used. These include upper and
lower alphabetic characters, numbers, and
standard punctuation marks.
New Password: In this field a revised
password can be entered. The password
must be a minimum of five characters, have
a maximum of 15 characters, and is case
sensitive. All 95 of the printable ASCII char-
acters can be used. These include upper
and lower alphabetic characters, numbers,
and standard punctuation marks.
Confirm New Password: For a new pass-
word to be considered valid, enter it identi-
cally into this field.
Submit: The Submit button is located
below the field for Confirm New Password.
To save changes made to the user name
and/or New password fields requires that
the Submit button be pressed. Changes
made will be effective upon the next attempt
at logging into the Model 5401A. Restor-
ing the Model 5401A to its default values
does not change the stored user name and
password.
Issue 2, July 2021
Model 5401A User Guide
Page 28
Studio Technologies, Inc.
System Menu
This menu has six display-only fields as
well as functions that allow the default set-
tings to be restored and the system to be
rebooted (restarted). Refer to Appendix E
for a view of the System menu.
One of the display-only fields shows the
hardware serial number and the remain-
ing six provide details about the firmware
(embedded software) that is being actively
utilized by the Model 5401A.
Serial Number: This is a display-only field
that shows the Model 5401A’s hardware
serial number. This number has been
assigned at the factory and cannot be
changed.
Version Information: The version informa-
tion section consists of five rows of infor-
mation that provides details about the five
firmware (embedded software) files that are
being used by the Model 5401A. These are
display only and will include a date if that is
specified as part of the firmware release.
Main MCU Firmware: This display-only
field shows the version number and asso-
ciated release date of the Model 5401A’s
Main MCU firmware. This firmware can
be field-updated using a USB flash drive.
Update details are provided in the Technical
Notes section of this guide.
Main FPGA Firmware: This display-only
field that shows the version number and
associated date of the Model 5401A’s Main
FPGA (field-programmable-gate-array) firm-
ware. This firmware can be field-updated
using a USB flash drive. Update details are
provided in the Technical Notes section of
this guide.
Sync FPGA Firmware: This display-
only field shows the version number and
associated date of the Model 5401A’s
synchronization board FPGA (field-program-
mable-gate-array) firmware. This firmware
can be field-updated using a USB flash
drive. Update details are provided in the
Technical Notes section of this guide.
Dante Product: This display-only field
shows the product version number and
associated date that’s stored in and being
utilized by the Dante interface. (The Dante
interface is implemented using a Brook-
lyn II module from Audinate.) This version
number is assigned by Studio Technologies
as an identifier when a file is released that
combines specific Model 5401A configura-
tion information along with Dante operat-
ing firmware. The firmware for the Model
5401A’s Dante interface can be updated by
way of an Ethernet connection using the
Dante Updater software application that’s
provided as part of the Dante Controller
software application.
Dante Firmware: This is a display-only field
that shows the version number of the firm-
ware associated with the Dante interface
(Brooklyn II module) that the Model 5401A
utilizes for Dante interconnectivity. No date
is associated with this file. The displayed
version number is assigned by Audinate
and can’t be changed by Studio Technolo-
gies. It is incorporated into the Dante Prod-
uct (.dnt) file that is released by Studio
Technologies’ specifically for the Model
5401A. As noted previously, this firmware,
part of the Dante product firmware, can
be updated by way of an Ethernet connec-
tion using the Dante Updater software
application.
Restore Default Settings: The Restore
Default Settings function allows many of the
Model 5401A’s default configuration settings
to be restored. However, it will not impact
the network configuration or user name and
password settings. For the defaults to be
restored the associated check box must be
enabled prior to pressing the Submit but-
ton. Be careful when using this function as
invoking it after enabling the check box will
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 29
immediately cause the defaults to be re-
stored. Refer to Appendix F for a list of the
default values.
System Reboot: The Reboot function is
located on the bottom of the System menu
webpage. It allows the Model 5401A to be
rebooted (restarted) without having to per-
form a power cycle. (The function can be
considered to invoke a “cold boot.”) For
a system reboot to take place the check
box must be enabled prior to pressing the
Reboot button. During normal operation a
system reboot will never be required. But
after changes are made to any of the unit’s
management interface network configura-
tion a reboot is required. A system reboot
will cause the three Ethernet interfaces to go
through a reconnection process, necessary
should any of the management network pa-
rameters be revised. (These changes can be
made by way of the Network menu choices
or using the front-panel display and buttons.)
Menu Text and Links
The following provides details on some of
the text and links that are presented on the
Model 5401A’s webpages.
Device Name: In the upper-right corner of
each Model 5401A webpage is the Dante
device name. This name is unique to each
device in a Dante deployment and is used
as part of the Dante subscription (channel
routing) process. The name can be changed
from within the Dante Controller application.
Identify Device Link: In the upper-right
corner of each webpage, directly below the
device name, is a link called Identify Device.
Clicking on it will cause the Dante identify
action to commence on the specific Model
5401A. The action will consist of the front-
panel display’s green backlight flashing five
times. This command will help confirm that
the web server on the desired Model 5401A
is being accessed.
Company Name Link: On the bottom of
each webpage is a link with the title Studio
Technologies, Inc. Clicking on this link will
cause the browser to open the Home web-
page of the Studio Technologies website.
Log Out Link; In the upper-right corner of
most of the Configuration menu webpages is
a link called Log Out. It will cause the Model
5401A’s web server to end the session, log-
ging out the user and returning to the Home
menu. To again access the configuration
webpages requires that the user click on the
Login tab and provide a valid user name and
password.
Operation
Now that the Model 5401A is installed and
configured it’s ready for use. The unit is de-
signed for continuous, unattended operation.
However, there are a number of nuances
in the unit’s operation. This may make it
worthwhile for personnel to spend some
time reviewing this section.
Upon application of AC mains or DC power,
the Model 5401A will go through a power-up
sequence. The eight bi-color LEDs on the
Model 5401A’s front panel will light green,
then light red in a confirmation sequence.
The unit’s graphics display will show the
Studio Technologies logo graphics image,
followed by a menu page that shows the
product name (Model 5401A) and the Dante
name. Then the version number of the Main
MCU firmware will display. After a few sec-
onds the screen saver mode, detailed later
in this section, will begin operation.
Upon power being applied the green LED
adjacent to the USB receptacle on the back
panel will flash once to indicate that its as-
sociated circuitry is performing correctly.
Also, upon power being applied to the Model
5401A the LEDs on the back panel associat-
ed with the unit’s three Ethernet RJ45 jacks
will briefly flash as a functional test.
Issue 2, July 2021
Model 5401A User Guide
Page 30
Studio Technologies, Inc.
After the Model 5401A has completed its
power-up sequences the unit will begin
operation. The eight front-panel LEDs will
reflect the real-time status of the unit’s major
functions. The front-panel display will allow
the viewing of over 20 menu pages show-
ing status and configuration conditions. In
addition, using the front-panel pushbutton
switches some of the unit’s configuration
settings can be revised as required.
The following paragraphs will detail the
operation of the front-panel LEDs.
Power LEDs
Two LEDs indicate the presence of incoming
AC mains and nominal 12 volts DC power.
They are labeled AC and DC and can light
green or red. When a source of AC mains
power is connected the AC LED will light
green. (This is actually in response to 12
volts DC that is being generated by the in-
ternally located AC mains input/12 volts DC
output power supply.) The LED labeled DC
will light green whenever a connected DC
source exceeds approximately 10 volts. The
DC LED will light red when the DC input is
between approximately 9 and 10 volts, indi-
cating a low-voltage condition. Once the DC
input is less than approximately 9 volts the
DC LED will not light and the Model 5401A
will no longer operate from the DC source.
Network LEDs
Three LEDs provide status indications re-
lated to the Model 5401A’s three Ethernet
network interfaces. Two of the LEDs are
associated with the Model 5401A’s Dante
primary and Dante secondary Ethernet
ports. They are labeled PRI and SEC. The
third LED, labeled MGMT, is associated with
the unit’s management Ethernet port. The
way in which the three Ethernet interfaces
and their associated status LEDs function
depend on the network configuration as
selected using the Dante Controller applica-
tion. The choices are Switched, Redundant,
Switched+Mgmt, and Redundant+Mgmt.
Switched Network Operation
PRI LED: The PRI LED will light red when no
Ethernet connection is present on the Dante
primary or Dante secondary Ethernet ports. It
will light green whenever a Gigabit Ethernet
connection is present on either the Dante
primary or the Dante secondary Ethernet port
and a link has been established. It will light
orange whenever a 100 Mb/s Ethernet con-
nection is present on either the Dante prima-
ry or the Dante secondary Ethernet port and
a link has been established.
SEC LED: The SEC LED will not light.
MGMT LED: When no Ethernet connection
is present on the management Ethernet port
the MGMT LED will not light. It will light green
whenever a Gigabit or 100 Mb/s Ethernet
signal is connected and a link has been
established.
Redundant Network Operation
PRI LED: The PRI LED will light red when no
Ethernet connection is present on the Dante
primary Ethernet port. It will light green when-
ever a Gigabit Ethernet connection is pres-
ent on the Dante primary Ethernet port and a
link has been established. It will light orange
whenever a 100 Mb/s Ethernet connection is
present and a link has been established.
SEC LED: The SEC LED will light red when
no Ethernet connection is present on the
Dante secondary Ethernet port. It will light
green whenever a Gigabit Ethernet connec-
tion is present on the Dante secondary
Ethernet port and a link has been estab-
lished. It will light orange whenever a 100
Mb/s Ethernet connection is present and a
link has been established.
MGMT LED: When no Ethernet connection
is present on the management Ethernet port
the MGMT LED will not light. It will light green
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 31
whenever a Gigabit or 100 Mb/s Ethernet
connection is present and a link has been
established.
Switched+Mgmt Network Operation
PRI LED: The PRI LED will light red when
no Ethernet connection is present on the
Dante primary or Dante secondary Ethernet
ports. It will light green whenever a Gigabit
Ethernet connection is present on the Dante
primary or Dante secondary Ethernet ports
and a link has been established. It will light
orange whenever a 100 Mb/s Ethernet con-
nection is present on either Ethernet port
and a link has been established.
SEC LED: The SEC LED will not light.
MGMT LED: The MGMT LED will not light if
an Ethernet connection is not present on the
Dante primary or Dante secondary Ethernet
ports. It will light green whenever a Gigabit
or 100 Mb/s Ethernet connection is present
on either the Dante primary or Dante sec-
ondary Ethernet port and a link has been
established.
Redundant+Mgmt Network Operation
PRI LED: The PRI LED will light red when no
Ethernet connection is present on the Dante
primary Ethernet port. It will light green
whenever a Gigabit Ethernet connection is
present on the Dante primary Ethernet port
and a link has been established. It will light
orange whenever a 100 Mb/s Ethernet con-
nection is present on the Dante primary Eth-
ernet port and a link has been established.
SEC LED: The SEC LED will light red when
an Ethernet connection is not present on the
Dante secondary Ethernet port. It will light
green whenever a Gigabit Ethernet connec-
tion is present on the Dante secondary Eth-
ernet port and a link has been established.
It will light orange whenever a 100 Mb/s
Ethernet connection is present on the Dante
secondary Ethernet port and a link has been
established.
MGMT LED: The MGMT LED will not light
if an Ethernet connection is not present
on the Dante primary Ethernet port. It will
light green whenever a Gigabit or 100 Mb/s
Ethernet connection is present on the Dante
primary Ethernet port and a link has been
established.
Dante LEDs
Two LEDs are associated with the Model
5401A’s Dante interface. The system LED,
labeled SYS, and the synchronization LED,
labeled SYNC, will both light red as the
Model 5401A’s Dante interface starts to func-
tion and awaits connection and full operation
with one or two local area networks (LANs).
(Two networks are utilized only when Dante
redundancy is enabled.) The SYS LED will
light red to indicate that the Dante interface
is not ready to pass data to other devices.
It will blink red if there is an issue commu-
nicating with the internal Dante Brooklyn II
module. It will light green when the Dante
interface is operating normally and is ready
to pass Dante data.
The SYNC LED will light red to indicate that
the Model 5401A’s Dante interface has not
established timing synchronization. The
complete action of the SYNC LED will de-
pend on the Switch configuration as set
using the Dante Controller application. If
Switched or Switched+Mgmt has been se-
lected then the SYNC LED will slowly flash
green if this specific Model 5401A is serving
as the PTPv1 Leader clock for the associ-
ated Dante network. This will be a normal
situation as usually this unit will be provid-
ing the timing reference for all of the other
Dante devices. The SYNC LED slowly flash-
ing green can be misconstrued as an error
condition, but it is not. The SYNC LED slowly
flashing green will mimic the action that other
Dante devices will perform if they are acting
as the Leader clock.
Issue 2, July 2021
Model 5401A User Guide
Page 32
Studio Technologies, Inc.
The SYNC LED will slowly flash orange if
the Model 5401A is serving as the PTPv1
Leader clock for the Dante network and its
failover mode is active. This would indicate
that the unit was specified to utilize the sync
input but is not able to do so. If the SYNC
LED is lit solid orange then the Model 5401A
is not acting as the PTPv1 Leader clock for
the Dante network and the failover mode is
active.
The SYNC LED lighting orange, whether
solid or flashing, would typically indicate an
error condition that should be resolved. The
SYNC LED will light solid green when the
Model 5401A is acting as the Follower clock.
In this case, the unit is using another Dante
device on the network to provide its timing
reference. This would not be a typical situa-
tion and might only occur while performing
system testing or serving in a backup role.
If Redundant or Redundant+Mgmt has been
selected then the SYNC LED will slowly
flash green if this specific Model 5401A
is serving as the PTPv1 Leader clock for
either the Dante primary or Dante second-
ary network. The SYNC LED will slowly flash
orange if this Model 5401A is serving as the
PTPv1 Leader clock for the Dante primary
network and its failover mode is active. This
would indicate that the unit was specified
to utilize the sync input but is not able to
do so.
If the SYNC LED is lit solid orange then the
Model 5401A is not acting as the PTPv1
Leader clock for the Dante primary network
and its failover mode is active. The SYNC
LED lighting orange, whether solid or flash-
ing, would typically indicate an error condi-
tion that should be resolved.
The SYNC LED will light solid green when
the Model 5401A is not acting as the PTPv1
Leader clock for the Dante primary and
Dante secondary networks, unless the unit
is locked to another Leader clock. In this
case, the unit is using another Dante device
to provide the timing reference for the Dante
primary network. This would not be a typical
situation and might only occur while perform-
ing system testing or serving in a backup
role.
The management webpages should be
utilized to observe the Model 5401A’s com-
plete sync status. Using the Home and Main
webpages, the status of the Dante primary
and Dante secondary interfaces, including
their support for PTPv1 and PTPv2, will be
displayed.
Note that it’s possible that up to 30 or 40
seconds may be required for the SYNC LED
to reach its final state after the Model 5401A
powers up or performs a reboot (restart).
Also, both the SYS and SYNC LEDs will
flash red whenever the Model 5401A’s net-
work configuration mode is changing. (This
would be performed using the Dante Con-
troller application.) After the revised network
configuration has been established the SYS
and SYNC LEDs will perform normally.
External Lock LED
An LED, labeled SYNC IN, is associated
with the status of the Model 5401A’s external
synchronization input. If the unit’s main clock
source has been configured to utilize an ex-
ternal source of sync then the LED will light
green if a valid source has been connected.
The SYNC IN LED will light red if a valid
signal has not been connected. This would
typically indicate an error condition that
should be investigated. If the Model 5401A’s
main clock source has not been selected to
use the external sync input then the SYNC
IN LED will function in a slightly different
manner. It will light green whenever a valid
source is connected to the external sync
input. It will not light if a valid source has
not been connected.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 33
RJ45 LED Indicators
On the Model 5401A’s back panel there are
three RJ45 jacks that are provided for inter-
facing with the unit’s three Ethernet ports.
Two of the ports are typically used for Dante
and the third for management functions.
The Ethernet ports are labeled Dante PRI,
Dante SEC, and MGMT. Associated with
each RJ45 jack are two LEDs. One LED
is labeled LINK and lights orange when a
GigE Ethernet connection has been estab-
lished with that specific port. The other LED
is labeled ACT and flashes green to indicate
activity, responding to Ethernet data travel-
ing through the specific port.
The Model 5401A’s three Ethernet ports,
as a group, can be configured, using the
Dante Controller application, to operate in
one of four network configuration modes:
Switched, Redundant, Switched+Mgmt, and
Redundant+Mgmt. Details about the four
network configuration modes are provided
in other sections of this guide. The manner
in which the LEDs associated with each
RJ45 jack will light depends on the network
configuration. The following sections detail
the operation of the LEDs based on the
specific network configuration.
Switched Network Mode
Dante PRI RJ45 LEDs:
LINK (Orange): Off if no Ethernet signal is
connected or if a 100 Mb/s Ethernet signal
is connected; lit if a GigE Ethernet signal is
connected.
ACT (Green): Off if no data traffic; flashes
to show data traffic.
Dante SEC RJ45 LEDs:
LINK (Orange): Off if no Ethernet signal is
connected or if a 100 Mb/s Ethernet signal
is connected; lit if a GigE Ethernet signal is
connected.
ACT (Green): Off if no data traffic; flashes
to show data traffic.
MGMT RJ45 LEDs:
LINK (Orange): Off if no Ethernet signal is
connected or if a 100 Mb/s Ethernet signal
is connected; lit if a GigE Ethernet signal is
connected.
ACT (Green): Off if no data traffic; flashes
to show data traffic.
Redundant Network Mode
Same as Switched.
Switched+Mgmt Network Mode
Dante PRI RJ45 LEDs:
LINK (Orange): Off if no Ethernet signal is
connected or if a 100 Mb/s Ethernet signal
is connected; lit if a GigE Ethernet signal is
connected.
ACT (Green): Off if no data traffic; flashes
to show data traffic.
Dante SEC RJ45 LEDs:
LINK (Orange): Off if no Ethernet signal is
connected or if a 100 Mb/s Ethernet signal
is connected; lit if a GigE Ethernet signal is
connected.
ACT (Green): Off if no data traffic; flashes
to show data traffic.
MGMT RJ45 LEDs:
LINK (Orange): Will not light.
ACT (Green): Will not light.
Redundant+Mgmt Network Mode
Same as Switched+Mgmt.
Issue 2, July 2021
Model 5401A User Guide
Page 34
Studio Technologies, Inc.
Front-Panel Display Page
Descriptions
The following sections provide information
about the Model 5401A’s front-panel menu
pages. Additional details can be found in the
Model 5401A Configuration section of this
guide. Refer to Appendix D for the menu
structure diagram.
Row One
There are five display pages associated with
the top row which we’ll refer to as row one.
They relate to the timing status of the as-
sociated Dante network, the Model 5401A’s
selected internal timing, parameters related
to the sync input, and display of timing pa-
rameters that can be useful for factory trou-
bleshooting.
Dante Sync Status Primary PTPv1: This
menu page will display the PTPv1 sync
status for the Dante primary interface. It
will show Leader, Follower, Link Down, or Er-
ror. The management webpages should be
utilized to observe the Model 5401A’s com-
plete sync status. Using the Home and Main
webpages, the status of the Dante primary
and Dante secondary interfaces, including
their support for PTPv1 and PTPv2, will be
displayed.
Current Clock Source: This menu page will
display which timing source is actively be-
ing used by the Model 5401A’s circuitry. The
possibilities are Internal, Internal (Failover
Active), Sync Input, Dante, Dante (Failover
Active), and ---. Should the text Failover
Active be present it will alternate on and off
as a warning of an abnormal condition. This
would typically warrant intervention.
Sync Input Type & Status: This display
page shows two parameters. The top line will
show the type of input that has been config-
ured for the sync input. The possibilities are
Word Clock, Video, or 10 MHz. The bottom
line will show the status of the sync input
circuitry. The possibilities are Locked,
Unlocked, Standby, and Idle.
Sync Input Termination: This menu page
will display the status of a terminating imped-
ance being applied to the sync input BNC
jack. The two possibilities are Off and On.
Phase Detector Deviation (Factory Use):
This menu page will display two numbers
related to how well the Model 5401A’s inter-
nal logic circuitry is “locking” to an external
timing reference. The information on this
menu page will only be relevant if the factory
has been contacted in regards to a technical
issue.
Row Two
Row two has five front-panel menu pages
that involve the management IP address and
related parameters. Two are display-only
and three allow changes to be made.
Current Management IP Address: This
menu page will show the IP address as-
sociated with the Model 5401A’s internal
management web server. This address can
be assigned automatically using the DHCP
protocol or, if a DHCP server is not available,
using the IPv4 link-local protocol. (An IP ad-
dress that has the format of 169.254.x.x was
assigned using IPv4 link-local.) The manage-
ment IP address can also be manually as-
signed with a fixed or static IP address. If no
Ethernet connection has been made the text
Link Down will be displayed.
If the Model 5401A’s network configuration in
the Dante Controller application is selected
for Switched or Redundant then this menu
page will show the IP address that’s associ-
ated with the connection made to the Model
5401A’s management RJ45 jack.
If the Model 5401A’s network configuration
in the Dante Controller application is select-
ed for Switched+Mgmt then the IP address
that is displayed will be associated with a
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 35
connection that is made to either the
Dante primary or Dante secondary Ethernet
interface.
If the network configuration in Dante
Controller has been selected for
Redundant+Mgmt then the IP address that
is displayed will be associated with a con-
nection that is made to the Dante primary
Ethernet interface.
Current Management Subnet Mask
Value: This menu page will show the sub-
net mask value setting that is active for the
management interface and associated web
server. If the IP address and related network
parameters were obtained by way of DHCP
then this field will display an IPv4 subnet
mask value in dot-decimal notation. If the
IP configuration mode is selected for Auto-
matic and the current IP address was ob-
tained by way of link-local, then 255.255.0.0
will show. It’s also possible that the subnet
mask value was manually entered as part of
a fixed or static IP address setting.
Management IP Configuration: This menu
page allows the display and revision of the
method that the Model 5401A will use to ob-
tain a management IP address and related
parameters. The choices are Automatic and
Manual. The selected configuration impacts
how the Model 5401A obtains the IP ad-
dress that is used for accessing the man-
agement web server and associated menu
webpages. This setting has no impact on
how the Model 5401A obtains IP addresses
for the Dante primary and Dante secondary
Ethernet interfaces.
An arrow icon will display in the upper-right
corner of this menu page. This indicates
that the setting can be changed. If the
active method is not the desired one, press
the Enter pushbutton switch located on the
front panel. Use the left and right arrow
buttons to select the desired method. Then
again press the Enter button. The entry will
be stored. To cause the Model 5401A to
use a new setting requires that the unit be
rebooted (restarted). This can be performed
using another front-panel menu page, a
selection in one of the management web-
pages, or by power cycling the unit.
Selecting the Automatic setting causes the
Model 5401A to use DHCP or, if DHCP is
not available, the IPv4 link-local protocol to
establish the IP address for the manage-
ment port. Even if the IP address was es-
tablished using link-local the DHCP protocol
will remain active. In this case, approxi-
mately every 30 seconds the Model 5401A’s
firmware will check for the presence of a
DHCP server. If one becomes available
then an IP address will be requested and,
when obtained, will automatically replace
the IP address that was previously estab-
lished by link-local.
The Manual setting allows the desired
IP address and related parameters to be
manually entered. This can be useful when
a fixed or static addressing scheme has
been established. In this way, a designated
IP address can be entered along with the
other necessary network parameters.
Note that to minimize the chance of los-
ing access to the management web server,
restoring the Model 5401A’s default configu-
ration values will not change the currently
selected IP address configuration choice.
Manual Management IP Address: This
menu page shows the stored IP address
associated with the connection used to
access the management web server. (This
address has nothing to do with the IP ad-
dress utilized by the Dante primary and
Dante secondary Ethernet interfaces.) It
will be utilized only when the manual mode
has been selected for the management IP
address configuration. When the IP address
configuration has been selected for Auto-
matic this field cannot be changed and a
Issue 2, July 2021
Model 5401A User Guide
Page 36
Studio Technologies, Inc.
lock icon will show in the upper-right corner
of the display.
Whenever the IP address configuration is
selected for Manual the manual IP address
can be modified as desired. This will be
indicated by a circle with arrows icon that
will show in the upper-right corner of the
display. To start the process of changing the
manual management IP address press the
Enter pushbutton switch on the front panel.
An icon with a wrench and screwdriver will
display to indicate that an edit is in process.
Use the left and right arrow pushbutton
switches to select which specific digit of
the IP address number is to be modified.
Press the up and down arrow pushbuttons
to select the desired number. The standard
dot-decimal notation is used to display and
revise the IP address. Once all the desired
changes have been made press the Enter
button to store them.
To cause the Model 5401A to use a new
setting requires that the unit be rebooted
(restarted). This can be performed using
another front-panel menu page, using a
function on a management webpage, or by
power cycling the unit. Restoring the Model
5401A to its default values will not change
the stored manual IP address.
Manual Management Subnet Mask Value:
This menu page shows the stored subnet
mask value associated with the connection
used to access the management web serv-
er. (This value has nothing to do with the
subnet mask values utilized by the Dante
primary and Dante secondary ports.) It will
be utilized only when the manual mode has
been selected for the management IP ad-
dress configuration. When the IP address
configuration has been selected for Auto-
matic this field cannot be changed and a
lock icon will show in the upper-right corner
of the display.
Whenever the IP address configuration is
selected for Manual the manual manage-
ment subnet mask value can be modified
as desired. This will be indicated by a circle
with arrows icon that will show in the up-
per-right corner of the display. To start
the process of changing the subnet mask
value press the Enter pushbutton switch
on the front panel. An icon with a wrench
and screwdriver will display to indicate that
an edit is in process. Use the up and down
arrow pushbutton switches to select the de-
sired subnet mask value. Once the desired
value has been selected press the Enter
button to store it.
To cause the Model 5401A to use a new
manual management subnet mask value re-
quires that the unit be rebooted (restarted).
This can be performed using another front-
panel menu page, using a function on a
management webpage, or by power cycling
the unit. Restoring the Model 5401A to its
default values will not change the stored
subnet mask value.
Row Three
Row three has a total of six menu pages.
Four of the menu pages relate to the Dante
primary interface with three of these allow-
ing both display and configuration changes
to be made. The fifth menu page allows the
configuration of the Ethernet switch inte-
grated circuit to be displayed. A sixth menu
page allows the Dante interface to be re-
booted (restarted).
Dante Device Name: The Dante de-
vice name is shown on this menu page.
This name is unique to each device in a
Dante deployment and is used as part of
the Dante subscription (channel routing)
process. The name can be changed from
within the Dante Controller application. The
text shown on this menu page is same as
is shown in the upper-right corner of each
Model 5401A management webpage.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 37
Dante Primary IP Configuration: This
menu page allows the display and revision
of the method that the Model 5401A’s Dante
interface will use to obtain the Dante prima-
ry IP address and related parameters. The
choices are Automatic and Manual. This
setting has no impact on how the Model
5401A obtains IP addresses for the Dante
secondary interface and management inter-
face webpages.
An arrow icon will display in the upper-right
corner of this menu page. This indicates
that the setting can be changed. If the ac-
tive method is not the desired one, press
the Enter pushbutton switch located on the
front panel. Use the left and right arrow
buttons to select the desired method. Then
again press the Enter button. The entry will
then be stored. To cause the Model 5401A
to use a new setting requires that the unit
be rebooted (restarted). This can be per-
formed using another front-panel menu
page, a selection in one of the management
webpages, or by power cycling the unit.
Selecting the Automatic setting causes
the Model 5401A’s Dante interface to use
DHCP or, if DHCP is not available, the
IPv4 link-local protocol to establish the IP
address used by the Dante primary inter-
face. (An IP address that has the format of
169.254.x.x was assigned using IPv4 link-
local.) Even if the IP address was estab-
lished using link-local the DHCP protocol
will remain active. In this case, the Model
5401A’s Dante interface will continue to
check for the presence of a DHCP server. If
one becomes available then an IP address
will be requested and, when obtained, will
automatically replace the IP address that
was previously established by link-local.
The Manual setting allows the desired
Dante primary IP address and related pa-
rameters to be manually entered. This can
be useful when a fixed or static addressing
scheme has been established. In this way, a
designated IP address can be entered
along with the other necessary network
parameters.
To cause the Model 5401A to use a re-
vised Dante primary IP address configura-
tion method requires that the unit’s Dante
interface be rebooted (restarted). This can
be performed using the reboot Dante front-
panel menu page or by rebooting the entire
Model 5401A. This latter action can be ac-
complished using the reboot system menu
page, using a function on one of the man-
agement webpages, or by power cycling
the Model 5401A.
Note that to minimize the chance of losing
access to the Dante network, restoring the
Model 5401A’s default configuration values
will not change the stored Dante primary IP
address configuration method.
Dante Primary IP Address: This menu
page shows the IP address associated with
the Dante primary interface. (This address
has nothing to do with the IP addresses
utilized by the Dante secondary and man-
agement interface ports.) It can be revised
only when the manual mode has been se-
lected for the Dante primary IP configura-
tion. When the IP address configuration has
been selected for Automatic this field cannot
be changed and a lock icon will show in the
upper-right corner of the display. If no Ether-
net connection has been made the text Link
Down will be displayed.
If the network configuration is selected in the
Dante Controller application for Switched or
Switched+Mgmt then the Dante primary IP
address will be associated with a network
connection made to either the primary or the
secondary RJ45 jacks on the Model 5401A’s
back panel. If the network configuration is
selected for Redundant or Redundant+Mgmt
then the Dante primary IP address will be
associated with the RJ45 jack labeled PRI
on the Model 5401A’s back panel.
Issue 2, July 2021
Model 5401A User Guide
Page 38
Studio Technologies, Inc.
Whenever the IP address configuration
is selected for Manual the manual Dante
primary IP address can be modified as
desired. This will be indicated by a circle
with arrows icon that will show in the up-
per-right corner of the display. To start the
process of changing the Dante primary IP
address press the Enter pushbutton switch
on the front panel. An icon with a wrench
and screwdriver will display to indicate that
an edit is in process. Use the left and right
arrow pushbutton switches to select which
specific digit of the IP address number is to
be modified. Press the up and down arrow
pushbuttons to select the desired number.
The standard dot-decimal notation is used
to display and revise the Dante primary IP
address. Once all the desired changes have
been made press the Enter button to store
them.
To cause the Model 5401A to use the new
Dante primary IP address setting requires
that the unit’s Dante interface be rebooted
(restarted). This can be performed using the
reboot Dante front-panel menu page. Re-
booting the entire the Model 5401A can also
be utilized to cause a new Dante primary
IP address to be used. This can be ac-
complished using the reboot system menu
page, using a function on one of the man-
agement webpages, or by power cycling the
Model 5401A. Restoring the Model 5401A
to its default values will not change a stored
Dante primary IP address.
Dante Primary Subnet Mask Value: This
menu page shows the stored subnet mask
value associated with the Dante primary
interface. (This value has nothing to do
with the subnet mask values utilized by the
Dante secondary or management ports.) It
will be utilized only when the manual mode
has been selected for the Dante primary IP
address configuration. When the IP address
configuration has been selected for Auto-
matic this field cannot be changed and a
lock icon will show in the upper-right corner
of the display.
Whenever the IP address configuration is
selected for Manual the subnet mask value
can be modified as desired. This will be
indicated by a circle with arrows icon that
will show in the upper-right corner of the
display. To start the process of changing the
subnet mask value press the Enter pushbut-
ton switch on the front panel. An icon with
a wrench and screwdriver will display to
indicate that an edit is in process. Use the
up and down arrow pushbutton switches to
select the desired subnet mask value. Once
the desired value has been selected press
the Enter button to store it.
To instruct the Model 5401A to use the new
Dante subnet mask value requires that the
unit’s Dante interface be rebooted (restart-
ed). This can be performed using the reboot
Dante front-panel menu page. Rebooting
the entire Model 5401A can also be used
to cause a new Dante primary subnet mask
value to be used. This can be accomplished
using the reboot system menu page, using
a function on one of the management
webpages, or by power cycling the Model
5401A. Restoring the Model 5401A to its
default values will not change a stored
Dante primary subnet mask value.
Ethernet Switch Configuration: This
menu page shows the Model 5401A’s net-
work configuration as determined by a set-
ting in the Dante Controller application. The
term “switch” refers to an Ethernet switching
and routing integrated circuit that is part
of the Model 5401A’s hardware. How this
integrated circuit is configured determines
the how the Model 5401A’s three Ether-
net ports will function. The field will show
Switched, Redundant, Switched+Mgmt, or
Redundant+Mgmt. It will also display Error
in the unlikely event that an error has oc-
curred in the Brooklyn II module that sup-
ports the Model 5401A’s Dante interface.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 39
Reboot Dante: This menu page allows
the Dante interface to be rebooted (re-
started). This can be useful to force the
Model 5401A’s Dante interface to utilize
revised Dante primary IP address and
related parameter configuration changes. It
can also be useful when troubleshooting a
Dante network issue. An arrow icon shows
in the upper-right corner of the reboot Dante
menu. To start the process of rebooting the
Dante interface press the Enter pushbutton
on the unit’s front panel. This will lead to
a confirmation page being displayed. Use
the left and right arrow pushbutton switches
to select the desired action. The choices
are to cancel or to confirm. Press the Enter
pushbutton switch to select the highlighted
action.
Note that if the Dante interface is rebooted
it may take 20 to 60 seconds for the Model
5401A’s operation to fully restore. And
during this time period the management
Ethernet port will also disconnect and then
reconnect.
Row Four
Row four contains six menu pages. Five
of the pages provide information about the
specific Model 5401A, including its serial
number and versions of the firmware (em-
bedded software) that are in use. It also in-
cludes a menu page that allows the system
to be rebooted (restarted).
Product Name & Serial Number: This
menu page shows the name of the prod-
uct (Model 5401A) and the hardware se-
rial number. The name and serial number,
along with three MAC addresses associated
with the Ethernet interfaces, are assigned
at the factory and cannot be changed.
Main MCU Firmware Version: This menu
page shows the version number of the
Model 5401A’s Main MCU firmware. This
firmware can be updated using a USB flash
drive. Update details are provided in the
Technical Notes section of this guide.
Main FPGA Firmware Version: This menu
page shows the version number of the
Model 5401A’s Main FPGA (field-program-
mable-gate-array) firmware. This firmware
can be updated using a USB flash drive.
Update details are provided in the Technical
Notes section of this guide.
Sync FPGA Firmware Version: This menu
page shows the version number Model
5401A’s internal synchronization board
FPGA (field-programmable-gate-array)
firmware. This firmware can be updated
using a USB flash drive. Update details are
provided in the Technical Notes section of
this guide.
Dante Product Version: This menu page
shows the product version number that’s
stored in and being utilized by the Dante
interface. The Model 5401A’s Dante inter-
face is implemented using a Brooklyn II
module from Audinate. This version number
is assigned by Studio Technologies as an
identifier when a file is released that com-
bines specific Model 5401A configuration
information along with Audinate-developed
Dante operating firmware. The firmware for
the Model 5401A’s Dante interface can be
updated by way of an Ethernet connection
using the Dante Updater software applica-
tion that’s provided as part of the Dante
Controller software application.
Reboot System: This menu page allows
the Model 5401A to be rebooted (restarted).
This can be useful to force the Model 5401A
to utilize all revised management and Dante
interface configuration changes. An arrow
icon shows in the upper-right corner of the
reboot Dante menu. To start the process
of rebooting the Model 5401A press the
Enter pushbutton on the unit’s front panel.
This will lead to a confirmation page being
displayed. Use the left and right arrow push-
Issue 2, July 2021
Model 5401A User Guide
Page 40
Studio Technologies, Inc.
button switches to select the desired action.
The choices are to cancel or to confirm.
Press the Enter pushbutton switch to select
the highlighted action.
After performing a system reboot (restart),
20 to 60 seconds may be required for the
Model 5401A’s operation to fully restore.
During this time period the management
Ethernet port will briefly disconnect and
then reconnect.
Screen Saver
A “screen saver” mode will automatically
activate two minutes after the last press of a
front-panel pushbutton switch. When active,
the screen saver mode will cause a continu-
ous sequence of five menu pages to acti-
vate. Each menu page will be present for
about three seconds before the next menu
page will display.
When the screen saver mode is active
pressing the Enter pushbutton switch on
the front panel will cause it to stop and the
current management IP address menu page
to immediate display. To cause the screen
saver mode to immediately start simultane-
ously press the left and right arrow pushbut-
ton switches on the front panel.
There are five menu pages that will display
when the screen saver mode is active.
Details regarding the information provided
in menu pages 2-5 were documented in
previously sections of this guide. The menu
pages consist of:
1. The Studio Technologies’ company logo
graphic.
2. The product name (Model 5401A) and
the Dante device name.
3. The Dante sync status.
4. The current clock source.
5. The current management IP address.
Technical Notes
PTPv1, PTPv2, and AES67
For clock synchronization “native” Dante
utilizes version 1 of the Precision Time
Protocol (PTPv1). Technically, the appli-
cable standard is IEEE 1588-2002, which is
what the Model 5401A supports for applica-
tions that utilize both single and redundant
Dante. When operating in the Redundant
or Redundant+Mgmt network modes, inde-
pendent PTPv1 server functionality is sup-
ported, one instance provided for the Dante
primary port and a second instance provid-
ed for the Dante secondary port.
Applications that utilize AES67 require PTP
version 2 (PTPv2) as covered under the
standard IEEE 1588-2008. (And following
details as specified in the SMPTE ST2059-2
profile.) The Model 5401A will provide sup-
port for PTPv2 if the AES67 mode has been
enabled in the Dante Controller application.
This is in addition to PTPv1 support; both
can function simultaneously. When AES67
mode has been enabled and Redundant
or Redundant+Mgmt mode is selected,
then both the Model 5401A’s Dante primary
and Dante secondary Ethernet interfaces
will provide independent PTPv2 server
functionality. (And to highlight, this is in
addition to PTPv1 functionality.)
In Dante-related AES67 applications the
Model 5401A can provide good PTPv2 func-
tionality. But the Model 5401A can’t serve
as a general-purpose PTPv2 grandmaster
clock. Limitations in Dante’s AES67 imple-
mentation restricts Studio Technologies’
ability to adjust PTPv2 operating parame-
ters, something that some applications may
require. Refer to Appendix G, located at the
end of the guide, for details on the default
PTPv2 implementation that the Model
5401A provides.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 41
Dante IP Addresses
If the Model 5401A’s Dante interface has
been configured in the Dante Controller
application for Switched or Switched+Mgmt
operation, by default the Model 5401A’s
Dante primary Ethernet interfaces will
attempt to automatically obtain an IP ad-
dress and associated settings using DHCP
(Dynamic Host Configuration Protocol). If
a DHCP server is not detected then an IP
address will automatically be assigned us-
ing the link-local protocol. This protocol is
known in the Microsoft® world as Automatic
Private IP Addressing (APIPA). It is also
sometimes referred to as auto-IP (PIPPA).
Link-local will randomly assign a unique IP
address in the IPv4 range of 169.254.0.1
to 169.254.255.254. In this way, multiple
Dante-enabled devices will connect to-
gether and automatically function, whether
or not a DHCP server is active on the LAN.
Even two Dante-enabled devices that are
directly interconnected using an RJ45 patch
cord should correctly acquire IP addresses
and be able to communicate with each
other. As previously discussed in this guide,
using Dante Controller the Model 5401A’s
Dante Ethernet IP address(es) and related
network parameters can also be set for
manual (fixed or static) operation.
If the Model 5401A’s Dante interface has
been configured in Dante Controller for
Redundant or Redundant+Mgmt operation
then both the Model 5401A’s Dante primary
and Dante secondary Ethernet interfaces
will attempt to automatically obtain IP ad-
dresses and associated network settings
using DHCP. If DHCP is not available then
link-local IP addresses will be assigned. If
automatic assignment of IP addresses is
not desired each interface can be individu-
ally configured using Dante Controller to
use a manual (fixed or static) IP address
and related network parameters.
The specific IP address assigned to each of
the Model 5401A’s Dante interfaces can be
identified using several methods. The Dante
Controller application will directly display the
network parameters of the primary and, if
utilized, secondary Ethernet interfaces. An-
other means is to utilize the Model 5401A’s
network configuration webpage to directly
display the IP addresses assigned to the
primary and, if utilized, secondary Ethernet
ports. The Model 5401A’s front-panel menu
system can also be selected to display the
Dante primary IP address.
Optimizing Dante Network
Performance
For best Dante audio-over-IP performance a
network that supports VoIP QoS (voice-over-
internet-protocol quality of service) capabil-
ity is recommended. This can typically be
implemented on virtually all contemporary
managed Ethernet switches. There are even
specialized switches that are optimized for
entertainment-associated applications. Also,
it’s recommended that IGMP snooping func-
tionality on Ethernet switch ports associated
with Dante devices be disabled. This can be
important, allowing Dante-related multicast
data traffic, including PTPv1, to be correctly
supported. Refer to the Audinate website
(audinate.com) for details on how to opti-
mize a network for Dante applications.
Management IP Address and
Configuration
It’s easy to determine the active IP address
being used by the Model 5401A’s manage-
ment Ethernet port. The most direct method
is to simply watch the front-panel screens
that are active in the “screen saver” mode.
This mode will enable automatically two min-
utes after the last press of any of the front-
panel buttons. The front-panel menu system
also allows the management IP address
to be displayed and, if required, revised. A
Issue 2, July 2021
Model 5401A User Guide
Page 42
Studio Technologies, Inc.
menu structure diagram is available in Ap-
pendix D of this guide. It’s also available as
a separate document on the Studio Tech-
nologies website.
By default, the Model 5401A’s management
Ethernet interface address configuration is
set for automatic. In this way, it will attempt
to automatically obtain an IP address and
associated settings using DHCP. If a DHCP
server is not detected an IP address will
automatically be assigned using the link-lo-
cal protocol in the IPv4 range of 169.254.0.1
to 169.254.255.254. There are two ways
that the management Ethernet IP address
and related network parameters can be set
to a manual (fixed or static) configuration.
The first method uses the front-panel display
and buttons to allow the management Eth-
ernet network parameters to be viewed and
revised as desired. An even easier method
might be to use the network configuration
webpage that is provided as part of the
Model 5401A’s management webpages.
Model 5401A Firmware
Update Procedure
It’s possible that updated versions of the
three firmware (embedded software) files
that are utilized by the Model 5401A’s
MCU (microcontroller) and two FPGA (field-
programmable-gate-array) integrated circuits
will be released to add features or correct
issues. Refer to the Studio Technologies’
website for the latest firmware files. The
Model 5401A has the ability to load appli-
cable firmware files into non-volatile memory
by way of a standard USB flash drive. The
Model 5401A implements a USB host func-
tion and provides access by way of a type
A receptacle located on the back panel.
The Model 5401A updates its firmware us-
ing three files. The Main MCU firmware is
named M5401A.bin, the Main FPGA firm-
ware is named DSMC.bit, and the Sync
FPGA firmware is named CLOK.bit.
The update process begins by preparing
a USB flash drive. The flash drive doesn’t
have to be empty (blank) but must be in the
personal-computer-standard FAT32 for-
mat. One, two, or all three of the firmware
files can be automatically loaded at essen-
tially the same time. On the flash drive’s
root folder, save the desired new firmware
files, ensuring that the required names are
specified. The file name for the Main MCU
firmware must be M5401A.bin. The file
name for the Main FPGA firmware must be
DSMC.bit. And the file name for the Sync
FPGA firmware must be CLOK.bit. Be
certain to use the eject command to ensure
that the file is correctly stored on the USB
flash drive.
Studio Technologies will supply each firm-
ware file inside a .zip archive file. While the
firmware file inside of the zip file will adhere
to the naming convention required by the
Model 5401A, the name of the zip file itself
will include the file’s version number. For ex-
ample, a zip file named M5401Av1r04MCU.
zip would indicate that version 1.04 of the
Main MCU firmware (M5401A.bin) is con-
tained within this zip file.
Once the prepared USB flash drive is in-
serted into the USB receptacle, located on
the Model 5401A’s back panel, the Model
5401A must be powered off and then pow-
ered on again. At this point the file(s) stored
on the USB flash drive will automatically
load. The precise steps required will be
highlighted in the following paragraphs.
To install one, two, or all three of the firm-
ware files follow these steps:
1. Remove power from the Model 5401A.
This will entail removing the AC mains
power connector or removing the con-
nector associated with the external
source of nominal 12 volts DC. (Both
must be disconnected if dual powering
has been implemented.)
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 43
2. Locate the USB receptacle on the
Model 5401A’s back panel. It is labeled
Firmware Update. Directly adjacent to
the USB receptacle is a small hole that
provides visual access to a green LED
indicator.
3. Insert the prepared USB flash drive into
the USB receptacle.
4. Apply power to the Model 5401A. Power
can be provided by connecting AC mains
or a source of nominal 12 volts DC.
5. After a few seconds the Model 5401A
will run a “boot loader” program that will
automatically load and save the new
firmware file(s) that are present on the
USB flash drive. The update process can
range from approximately 10 seconds to
approximately 60 seconds, depending
on which of the three files are going to
be updated. While files are being loaded
the green LED, located adjacent to the
USB receptacle, will flash slowly. Once
the entire loading process has complet-
ed the Model 5401A will reboot (restart)
using the newly saved firmware.
6. At this time the Model 5401A is function-
ing with the newly loaded firmware and
the USB flash drive can be removed.
7. It’s a good idea to confirm that the de-
sired Model 5401A’s Main MCU, Main
FPGA, and Sync FPGA firmware ver-
sions are loaded and operating as
expected. There are two methods for
observing the Model 5401A’s firmware
version numbers. The most direct is to
use the front-panel display. Alternately,
the System webpage from the manage-
ment webpages can be utilized.
Note that no harm will occur if power is ap-
plied to the Model 5401A that has a USB
flash drive connected that doesn’t have rel-
evant files in its root folder. Upon power up
the green LED, located adjacent to the USB
receptacle, will flash on and off rapidly for a
few seconds to indicate that a valid file has
not been found. After this warning, normal
operation using the unit’s existing firmware
will begin.
Dante Firmware Update
As previously discussed in this guide, the
Model 5401A implements Dante connec-
tivity using the Brooklyn II module from
Audinate. The Dante Controller software ap-
plication can be used to determine the ver-
sion of the firmware (embedded software)
that resides in the Brooklyn II module. The
System webpage provided by the Model
5401A’s management web server can also
be used to identify the firmware version.
The firmware (embedded software) residing
in the Brooklyn II module can be updated
using the Model 5401A’s Dante primary Eth-
ernet port. Performing the update process
is easily accomplished using an automated
method called Dante Updater that’s includ-
ed as part of the Dante Controller software
application. The Dante Controller applica-
tion is available, free of charge, from the
Audinate website (audinate.com).
The latest Model 5401A firmware file, with
an extension of .dnt, is available on the Stu-
dio Technologies’ website as well being part
of Audinate’s product library database. The
latter allows the Dante Updater software ap-
plication that is included with Dante Control-
ler to automatically query and, if required,
update the Model 5401A’s Dante interface.
Restoring Model 5401A’s
Default Configuration Values
A command in the System Information
webpage provided by the Model 5401A’s
management web server allows most of the
configuration settings to be restored to their
default configuration values. This can be
useful but must be used with caution. Any
customization made to the Model 5401A’s
Issue 2, July 2021
Model 5401A User Guide
Page 44
Studio Technologies, Inc.
configuration will be lost. This can be offset
in a positive way by returning the Model
5401A to a known configuration, a point that
might aid in troubleshooting an issue. Refer
to Appendix F for a list of the default values.
Lost User Name and/or
Password
As is covered in detail in other sections
of this guide, gaining access to the Model
5401A’s configuration menu webpages
requires entering the correct user name
and password. If the default entries, both
of which are guest, are stored for use then
they will display on the Login menu web-
page. Pressing the Log In button on that
webpage will then access the Main configu-
ration webpage. If either or both the user
name and the password have been config-
ured to be something other than guest (the
default) then nothing will show in the fields
associated with the login menu webpage.
If knowledge of the stored user name and/or
password is “lost” then the Model 5401A
includes a “backdoor” to allow access. But
as a security measure physical access to
the unit is required to utilize that access
method; there is no means to access the
unit via an Ethernet port without knowledge
of the user name and password. The exact
process of accessing the Model 5401A’s
configuration webpages without knowledge
of the user name and/or password is de-
tailed in Appendix H, located at the end of
this guide.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 45
Specifications
Applications:
High-performance Leader clock for Dante audio-over-IP
applications. Also supports AES67-2018 applications.
In addition, provides audio tones on Dante transmitter
(output) channels for general-purpose use and a word
clock synchronization output.
Precision Time Protocol (PTP) Support: PTPv1
(IEEE 1588-2002) for Dante; PTPv2 (IEEE 1588-2008) for
AES67-2018
Timing Reference:
Source: internal time base, external sync input, or via
an existing Dante network, selectable
Internal Time Base:
Type: 24.576 MHz temperature-stabilized crystal
oscillator
Initial Accuracy: 1 ppm (parts-per-million)
Long-Term Accuracy: 1 ppm (parts-per-million) per
year
Temperature Stability: ±280 ppb (parts-per-billion),
0-50 degrees C
Sync Input:
Compatible Sources: word clock, bi-level video,
tri-level video, 10 MHz
Termination: 50 ohms (10 MHz), 75 ohms (word clock
or video), or high Z (unterminated), selectable
Word Clock Compatibility: square wave, 5 Vpp
nominal unloaded, 44.1, 48, 88.2, 96, 176.4, or 192 kHz
Video Signal Compatibility: bi- or tri-level, 1 Vpp
nominal into 75 ohm load
10 MHz Signal Compatibility: sine wave, 3 Vpp
nominal into 50 ohm load
Word Clock Output:
Type: square wave
Rate: 44.1, 48, 88.2, 96, 176.4, or 192 kHz
Source Impedance: 75 ohms
Amplitude: 5 Vpp, unterminated; 2.5 Vpp, externally
terminated with 75 ohms
Jitter: 0.01 UI (using internal time base)
Network Audio Technology:
Type: Dante audio-over-IP
AES67-2018 Support: yes
Dante Domain Manager™ (DDM) Support: yes
Ethernet Interface Configuration: Switched,
Redundant, Switched+Mgmt, or Redundant+Mgmt,
selectable
Clock Source: follows Model 5401A timing reference
configuration
Sample Rate: 44.1, 48, 88.2, 96, 176.4, or 192 kHz,
selectable
Bit Depth: 24
Number of Dante Transmitter (Output) Channels: 8
Number of Dante Transmitter Flows: 32
Audio Tone Generator:
Type: continuous sine wave signals on Dante
transmitter (output) channels
Number of Channels: 8
Frequency: 1 Hz to 22 kHz, individually configurable
in 1-Hz steps
Amplitude: 0 to –99 dBFS, individually configurable
in 1-dB steps
Distortion (THD+N): <0.0001% (<–121 dB), measured
at 1 kHz, –1 dBFS
Network Interfaces:
Qty: 3. Dante Primary, Dante Secondary, and
Management
Type: 1000BASE-T Gigabit Ethernet (GigE) per IEEE
802.3ab (100 Mb/s supported but not recommended for
optimal performance; 10 Mb/s not supported)
Ethernet Connection NIC Status LEDs: one link and
one activity for each Ethernet interface
Front-Panel Display: backlit LCD
Front-Panel LEDs: 8, dual-color
Functions: provides indication of condition of incoming
AC and DC power, status of three Ethernet interfaces,
status of Dante connectivity, and status of sync input
Software Updating: USB flash drive supports updating
of Main MCU, Main FPGA, and Sync FPGA firmware
(embedded software); Dante interface updated via
Ethernet interface
Power Sources:
AC Mains: 100 to 240 V, 50/60 Hz, 5 W maximum
DC: 10 to 18 V, 0.5 A max: 110 uA maximum with
12 volts DC and AC mains present, 190 uA maximum
with 18 volts DC and AC mains present
Issue 2, July 2021
Model 5401A User Guide
Page 46
Studio Technologies, Inc.
Connectors:
Sync Input, Word Clock Output: 2, BNC jack (female
connector), per IEC 61169-8 Annex A
Ethernet: 3, RJ45 jack
USB: type A receptacle (used only for updating
firmware)
DC Input: 4-pin male XLR (pin 1 negative, pin 4
positive)
AC Mains Input: 3-blade male, IEC 320 C14-
compatible (mates with C13)
Environmental:
Operating Temperature: 0 to 50 degrees C (32 to
122 degrees F)
Storage Temperature: –40 to 70 degrees C (–40 to
158 degrees F)
Humidity: 5 to 95%, non-condensing
Altitude: not characterized
Dimensions (Overall):
19.00 inches wide (48.3 cm)
1.72 inches high (4.4 cm)
7.9 inches deep (20.1 cm)
Mounting: one space (1U) in a standard 19-inch rack
Weight: 3.0 pounds (1.4 kg)
Specifications and information contained in this
User Guide subject to change without notice.
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 47
Appendix A–Compatible Sync Input Sources
The Model 5401A’s external sync input has been tested and confirmed for correct operation
with the following signals:
Word Clock: Square wave signal with rate of 44.1, 48, 88.2, 96, 176.4, and 192 kHz
10 MHz: Sine wave signal with an amplitude of 1 Vrms, nominal, terminated with 50 ohms
Bi-Level and Tri-Level Video: See table below
Video Format
NTSC (“Black Burst”)
PAL (“Black Burst”)
720p/50 Hz
720p/59.94 Hz
720p/60 Hz
1080psf/23.98 Hz
1080psf/24 Hz
1080i/50 Hz
1080i/59.94 Hz
1080i/60 Hz
1080p/23.98 Hz
1080p/24 Hz
1080p/25 Hz
1080p/29.97 Hz
1080p/30 Hz
1080p/50 Hz
1080p/59.94 Hz
1080p/60 Hz
Issue 2, July 2021
Model 5401A User Guide
Page 48
Studio Technologies, Inc.
Appendix B–Network Configuration Examples
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 51
Appendix C–Dante Controller Network Default
Configuration Values
Dante Interface Default Values:
Device Config, Sample Rate: 48k
Device Config, Clocking, Unicast Delay Requests: Disabled
Device Config, Device Latency: Latency: 1.0 msec
Network Config, Switch Configuration, Current: Switched
Network Config, Addresses: Obtain an IP Address Automatically (default)
AES67 Config, AES67 Mode, Current: Disabled
Leader Clock, Preferred Leader: Enabled
Leader Clock, Enable Sync to External: Enabled
Issue 2, July 2021
Model 5401A User Guide
Page 52
Studio Technologies, Inc.
Appendix D–Menu Structure
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 53
Appendix E–Screen Captures
Issue 2, July 2021
Model 5401A User Guide
Page 58
Studio Technologies, Inc.
Main Menu:
Main Clock Source: Internal
Failover Clock Source: Dante
Force Preferred Leader: Enabled
Sync Input Menu:
Type: Word Clock
Termination: On
Tone Generator Menu:
Tone 1: Frequency 100 Hz, Level –21 dBFS
Tone 2: Frequency 200 Hz, Level –22 dBFS
Tone 3: Frequency 300 Hz, Level –23 dBFS
Tone 4: Frequency 400 Hz, Level –24 dBFS
Tone 5: Frequency 500 Hz, Level –25 dBFS
Tone 6: Frequency 600 Hz, Level –26 dBFS
Tone 7: Frequency 700 Hz, Level –27 dBFS
Tone 8: Frequency 800 Hz, Level –28 dBFS
Network Menu, Management Interface:
IP Address Configuration: Automatic
Manual IP Address: 192.168.1.26
Manual Subnet Mask: 255.255.255.0
Manual Gateway: 192.168.1.1
(Note: Using the Restore Default Settings command in the System menu does not restore
these items to their default configuration values.)
Access Menu, Management Login Credentials:
User Name: guest
Password: guest
(Note: Using the Restore Default Settings command in the System menu does not restore
these items to their default configuration values.)
Appendix F–Model 5401A Default Configuration Values
Model 5401A User Guide
Issue 2, July 2021
Studio Technologies, Inc.
Page 59
Appendix G–PTPv2 (IEEE® 1588-2008) Default
Characteristics
Notes:
1. For Model 5401A PTPv2 support to be active AES67 compatibility check box must be
enabled in Dante Controller application.
2. These default configuration characteristics apply to both the Dante primary and Dante
secondary Ethernet interfaces.
Domain: 0
Priority 1: 114
Clock Class: 248
Accuracy: Unknown (0xFE)
Variance: 61536
Priority 2: 112
Unique ID: 00:1D:C1:XX:XX:XX
DSCP: EF (46)
Issue 2, July 2021
Model 5401A User Guide
Page 60
Studio Technologies, Inc.
Appendix H–Accessing the Unit when User Name
and/or Password are Not Known
Follow this procedure to access the Configuration menu webpages if the user name and/or
password is not known.
1. Remove power from the Model 5401A.
2. Press and hold the left arrow and Enter buttons.
3. While continuing to hold the two buttons apply AC Mains or 12 volts DC power.
4. Continue to hold the two buttons and allow the Model 5401A to start. The Status LEDs
on the front panel will first light green then light red in their start-up sequence.
5. Once the Status LEDs have completed their start-up sequence release the two buttons.
6. Use a web browser to access the Model 5401A’s Configuration menu webpages. The
management port’s IP address to use is shown in the current management IP address
page on the front-panel display. Pressing the Enter button will cause the current manage-
ment IP address page to immediately show on the front-panel display.
7. From the Home webpage select the Login webpage tab. Leave the user name and pass-
word fields empty and click the Log In button. This will allow access to the Configuration
menu selections. At this point your web browser should display the Model 5401A’s Home
webpage.
8. Navigate to the Access menu. From this webpage you will be able to view the stored user
name. You will not be able to view the previously saved password. Enter and confirm a
new password. Henceforth, to access the Model 5401A’s Configuration menu will require
the use of the stored user name and password.