Priman PN-8830 Quick Start Manual
Text of the manual
Multi-Tyres simultaneous Inflation&N2P Feature
Nitrogen Tyre Inflation System Operation Steps
1. Set final target pressure using the + and - buttons. The LCD
screen will show the target pressure.
2. Connect air hose(s) to tire valve stem(s).
3. Turn red valve handle to the “FILL” position.
4. Press “FILL/PURGE” once for standard inflation or Push
and hold “FILL/PURGE” for 2 seconds for nitrogen
conversion.
5. When unit “beeps” and the LCD screen flashes the target
pressure, tire inflation is complete.
6. Allow 15 seconds for the pressure in all tires to equalize,
then turn red valve handle to the “STOP” position.
7. Immediately remove hose(s).
1.1 This Manual
Congratulations on selecting the nitrogen tire inflation equipment. Please read and
familiarize yourself with this manual before attempting to use this unit. Although this
unit is very simple to operate, the user will be working with high-pressure gas that
must be handled with caution. Compressed gas, if handled improperly, can result in
serious or fatal injury.
1.2 General Specifications *
Power Requirement 100-240Vac 50/60Hz
Operating Temperature -20ºC/-4°F to 70ºC/158°F
Compressed Air Input Range 87-123psi/860-850kPa/6-8.5bar
Nitrogen Purity 95-99.99%
Nitrogen Output 70L/min (2.5cfm) @ 131psi/9bar/900kPa
Maximum Nitrogen Pressure in Tank 116psi/800kPa/8bar
Accuracy +/-1 psi, 7 kPa, 0.07 bar
Units of Measurement psi, kPa, bar
*Note: Specifications may vary for non-standard equipment. Contact your service
agent for further information.
1.3 Safety
General
The unit has standard process plant components and electrical equipment, which can
be hazardous to individuals unfamiliar with such equipment. It is the users’
responsibility to permit only trained and qualified process plant operators familiar
with the handling of compressed gases to operate this equipment.
Breathing
This unit is designed to produce high purity nitrogen from 95 – 99.99% purity.
Nitrogen is a colorless, odorless gas that will not support life. If released in an
unventilated area, it will displace the oxygen and can cause injury or death from
asphyxiation.
CAUTION: Nitrogen gas represents an extreme asphyxiation hazard when not
handled properly. Product gas should not be vented or otherwise discharged
except through the normal piping system. Appropriate signs should be placed in
the area of the nitrogen system warning of the hazards.
1. Unpack the carton and identify the components.
Description Quantity
Generator Unit
1
System Pressure Gauge 1
Tire Fill Hoses with Chucks 2
Hose/Cord Storage Hooks 4
Air Supply Caution
Compressed air should be supplied to the unit with the air dried to a dew point
temperature lower than the expected minimum ambient temperature. Typical dew
point from a properly sized refrigerated air dryer is sufficient (+40°F, 4°C). No water
in liquid form should be present. Inlet air pressure must be less than 123 PSI.
2.1 Nitrogen Generator - Exploded View
3.0 Preparation for Use
1. Plug unit power cord into power source.
2. Connect a compressed air supply line to the inlet located on the Pre-Filter.
3. Turn the red handle of the Fill Control Valve (Fill/Stop Valve) to the “STOP”
position.
4. Turn the unit on by depressing the Power Switch. The Unit will immediately begin
to produce nitrogen. The nitrogen pressure gauge located on the Unit above the
Pre-Filter assembly will indicate the nitrogen pressure in the system.
5. The equipment is now ready to use.
WARNING
To avoid the risk of personal injury, especially to the eyes, face and skin, DO NOT
direct the air stream at any person(s).
CAUTION
To avoid equipment damage, never exceed the maximum inlet pressure.
NOTE: The filter bowls on the Pre-Filter assembly will accumulate water and oil
when the generator is in operation but drain automatically whenever the generator unit
is powered down or the filter housings are depressurized. It is recommended that the
generator unit be powered down when not in use to ensure filter bowls remain drained
and conserve power/unit life.
It is important that the filter elements are replaced on a regular basis (at least
every 6 months) to prevent contaminates from entering the Unit.
4.0 Control Panel
4.1 Switch and Control Functions
1. "-": Reduce final target pressure
2. "+": Increase final target pressure
3. Power Switch: Turns unit on and off
4. "FILL/PURGE": Inflation/Deflation start
5. Fill Control Valve
6. Outlets: For tire fill hoses
7. Compressed Air Inlet
8. Nitrogen Pressure Gauge: Indicates system nitrogen pressure
9. Nitrogen Outlet: For optional storage tank
5.0 Operation