powersoft D-Cell 504 Service Manual

Specifications

Brand: powersoft
Category: Amplifier
Model: D-Cell 504 (Service Manual)
File Type: PDF
File Size: —
Pages: 12

Read Online

Read the powersoft D-Cell 504 Service Manual online using the built-in PDF viewer.

Text of the manual

Keep This Manual For Future Reference

© 2012 - 2013 Powersoft powersoft_DCell504_servman_en_v1.2 service manual D-Cell 504 REV 1.2 June 2013

Table of contents

1 Important safety instructions 3 2 Tools 3 3 Disassembly the power supply 4 4 Disassembly the amplifier board 4 5 Assembly outline D-Cell 504 power supplies 5 6 Assembly outline D-Cell 504 amplifier board 6 7 Checking the power supply 7 8 Failure of the varistor 7 9 Failure of the inductor 8 10 Checkng the output stage 8 11 Failure of the MOSFETs 9 12 Further tests 9 13 Spare part list 10 D-Cell 504 10 1 Important safety instructions WE RECOMMEND THAT ALL SERVICE OPERATIONS ARE CARRIED OUT BY A TECHNICIAN IN THE MANNER DESCRIBED IN THIS GUIDE. IF NOT EXPLICITLY STATED OTHERWISE, DISCONNECT THE AMPLIFIER FROM THE MAINS BEFORE OPERATING THE AMPLIFIER. WARNING! INTERNAL CAPACITORS BANK COULD BE CHARGED AND HARMFUL This technical document is aimed to be a support guide in solving the most recurrent failures of the D-Cell504 amplifier modules. The troubleshooting approach will help you characterize the kind of fault you incur. A recovery method and the related assembly outline detail is thoroughly explained for the most common faults. The components to be replaced are clearly shown in red print to help their identification. At the end of this guide you can find a detailed list with the description and the respective Powersoft internal reference code of the spare parts. 2 Tools f f Phillips PH 0 screwdriver. f f Phillips PH 1 screwdriver. f f Small cutter f f Tweezers f f Function generator or test CD + CD player. f f Double trace oscilloscope (it must be disconnected from the ground) and probes. f f Multimeter. f f Soldering station. f f Mains insulation transformer/variac. 3 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN !

3 Disassembly the power supply

1. Remove the six top cover fixing screws 2. Carefully remove the PSU board from the heat sink 4 Disassembly the amplifier board 1. Remove the six top cover fixing screws 2. Carefully remove the PSU board from the heat sink FIGURE 1: DC Power supply: remove six screws. FIGURE 2: AC Power supply: remove six screws. FIGURE 3: D-Cell 504 amplifier board: remove six screws. 4

5 Assembly outline D-Cell 504 power supplies

FIGURE 4: D-Cell 504 AC power supply. FIGURE 5: D-Cell 504 DC power supply. 5

6 Assembly outline D-Cell 504 amplifier board

FIGURE 6: D-Cell 504 amplifier board - Top view. FIGURE 7: D-Cell 504 amplifier board - Bottom view. 6

7 Checking the power supply

Evidence of a fault in the power supply stage is a blown main fuse (located close to the main switch). Before replacing it, check if the protection varistor is also blown. If not, disassemble the power supply board from the chassis and check all components as illustrated in the following paragraphs. If the protection varistor is blown, move on to the next step regarding the varistor issue 8 Failure of the varistor A varistor RV1 short circuit, resulting in its permanent damage, can occur if a mains voltage higher than 250VAC is applied to the D-Cell PSU. In this case the main fuse is also always blown. 1. Components to be replaced: f f RV1 varistor f f F1 Fuse We recommend anchoring the varistor with silicone glue to the nearest capacitor. FIGURE 8: Fuse. FIGURE 9: Fuse on PCB. 7

9 Failure of the inductor

If the 47 µH inductor in position L835T should fail, please replace it with a new inductor of the same nominal value but with a maximum current tolerated of 1.3 A. This specific power supply fault is present in first series power supplies equipped with inductors with an inadequate maximum current tolerance. 1. Components to be replaced: f f 47 µH inductor We recommend securing the inductor to the body of the coil with silicone. 10 Checkng the output stage Hold the probes of a multimeter on the two fuses in the secondary stage of the power supply, F800T and F8001T. Then check in the AMP stage which of the two channels has at least one MOSFET with the drain- source junction short circuited FIGURE 10: L825T inductor. FIGURE 11: L825T inductor position on the PCB. FIGURE 12: Output fuses on the PCB. 8

11 Failure of the MOSFETs

1. The MOSFETs are located on the bottom side of the amplifier’s PCB. 2. Components to be replaced: f f Channel 1 MOSFETs Q200, Q201 f f Channel 2 MOSFETs Q500, Q501 We recommend to carefully position the Sil-Pads to ensure the proper heat exchange between the com- ponents and the chassis. 12 Further tests 1. After checking and replacing all the defective components, try to test the module applying an incremental voltage through a variac. 2. Connect the probes of your multimeter to the CN800T connector on the power supply board; with respect to ground: f f on pins 1 to 4 sense +VCC, f f on pins 12 to 16 sense –VCC. 3. The unit should start to work at about 90 VAC. The Rail voltages ±VCC must be about ±40VDC. FIGURE 14: MOSFETs. FIGURE 13: Output MOSFETs on the bottom side of the PCB. 9

13 Spare part list

D-Cell 504 Powersoft code Description Position FU000020 Fuse 3.15A 250VDc (5x20mm) Fast CF Series Main switch VR000006 VARISTOR S20K300 RV800T LI000015 PTVA 47UH 1.3A H=14mm D=9.4mm L835T FUS00001 FUSE 10A 6.1mmx2.69mm FAST F serie451 LITTELFUSE F800T, F801T MO000043 IRC IRFB5615PBF 150V/25A/32mOhm Q200, Q201, Q500, Q501 IS000042 GAP PAD ULTRASOFT 40MILS 18X50 DIGIMOD Q200, Q201, Q500, Q501 10

Via Enrico Conti, 5

50018 Scandicci (FI) Italy Tel: +39 055 735 0230 Fax: +39 055 735 6235 General inquiries: [email protected] Sales: [email protected] Application & technical support: [email protected] Service & maintenance: [email protected] www.powersoft-audio.com © 2012 - 2013 Powersoft powersoft_DCell504_servman_en_v1.2

Other Amplifier Manuals