Datalogic Gryphon I GBT4100 Quick Reference Manual
Text of the manual
Gryphon™ I GBT4100
General Purpose Handheld
Linear Imager Barcode Reader
with Bluetooth® Wireless Technology
Quick Reference Guide
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the con-
tents of this documentation or the procedures described therein
may be reproduced or transmitted in any form or by any means
without prior written permission of Datalogic Scanning, Inc. or
its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Owners of Datalogic products are hereby granted a non-exclu-
sive, revocable license to reproduce and transmit this documen-
tation for the purchaser's own internal business purposes.
Purchaser shall not remove or alter any proprietary notices,
including copyright notices, contained in this documentation
and shall ensure that all notices appear on any reproductions of
the documentation.
Should future revisions of this manual be published, you can
acquire printed versions by contacting your Datalogic represen-
tative. Electronic versions may either be downloadable from the
Datalogic website (www.scanning.datalogic.com) or provided
on appropriate media. If you visit our website and would like to
make comments or suggestions about this or other Datalogic
publications, please let us know via the "Contact Datalogic"
page.
Disclaimer
Datalogic has taken reasonable measures to provide informa-
tion in this manual that is complete and accurate, however, Dat-
alogic reserves the right to change any specification at any time
without prior notice.
Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the
E.U. All other brand and product names may be trademarks of
their respective owners.
Patents
This product is covered by one or more of the following patents.
Design Pat.: USD599,799; USD 606,076S; EP 870,787; CN
1,067,263.
US Pat.: 5,144,118; 5,311,000; 5,481,098; 5,493,108; 5,929,421;
5,992,740; 6,098,883; 6,260,764; 6,443,360 B1; 6,517,003 B2;
6,631,846 B2; 6,808,114 B1; 6,817,525 B2; 6,997,385 B2; 7,075,663
B2; 7,387,246 B2.
European Pat.: 789,315 B1; 926,620 B1; 962,880 B1; 997,760 B1;
1,128,314 B1; 1,128,315 B1; 1,164,536 B1; 1,217,571 B1; 1,396,811
B1; 1,413,971 B1.
Table of Contents
Software Product Policy .............................................................................. 4
Customers Under Software Support ........................................... 4
Configuring the Base Station .................................................................... 5
Changing the Base Station Position ................................. 5
Connecting the Base Station ..................................................................... 7
Securing the DC Power Cord (Optional) ......................... 8
Using the BC40xx™ Radio Base ....................................................10
Radio Base LEDs ..................................................................... 10
Charging the Batteries ...............................................................................11
Battery Safety .....................................................................................12
Replacing the Batteries ..................................................................14
Linking the Reader ......................................................................................16
Link Datalogic RF Devices to Base................................... 16
Link Scanner to Bluetooth Adapater .............................. 16
System and Network Layout ........................................................17
Typical Setup with Cradle and Host................................ 17
Selecting the Interface Type ....................................................................18
Interface Selection ...........................................................................18
Configuring the Interface ................................................... 18
Keyboard Interface................................................................ 21
Scancode Tables .................................................................... 23
Country Mode......................................................................... 23
Caps Lock State ...................................................................... 28
Numlock.................................................................................... 29
Programming ................................................................................................30
Using Programming Barcodes .....................................................30
Configure Other Settings ...............................................................30
Resetting Standard Product Defaults ........................................30
Stand Detection ...........................................................................................31
Technical Specifications ............................................................................32
LED and Beeper Indications .....................................................................35
Error Codes ....................................................................................................37
Base Station Indications ............................................................................38
Statement of Agency Compliance ........................................................39
FCC Class B Compliance Statement ...........................................39
FCC RF Radiation Exposure Statement.......................... 40
Canadian Notice ................................................................................40
Power Supply .....................................................................................40
Imager Labeling ................................................................................41
Cleaning ..........................................................................................................41
WEEE Statement ..........................................................................................42
Warranty .........................................................................................................43
Ergonomic Recommendations ...............................................................44
Services and Support .................................................................................45
Quick Reference Guide
1
Datalogic Scanning, Inc.
GRYPHON™ PRODUCT SERIES
END USER LICENSE AGREEMENT
Notice to End User: The Datalogic Product you have acquired contains embed-
ded Software, which is integral to the product's operation. This Software is
being provided to you under license, subject to the terms and conditions of this
Agreement. If you use the Datalogic Product, you will be deemed to have
accepted the terms and conditions of this Agreement. If you do not intend to be
bound to the terms of this Agreement, Datalogic is not willing to license the
Software to you, you may not use the Datalogic Product or the Software, and
you must contact the party from whom you acquired the Datalogic Product for
instructions.
This End User Software License Agreement ("Agreement") is a legally binding agree-
ment governing the licensing of the Software and Documentation by Datalogic Scan-
ning, Inc. and its Affiliates ("Datalogic") to the entity or person who has purchased or
otherwise acquired a Datalogic Product ("End User"). For purposes of this Agreement,
any software that is associated with a separate end-user license agreement is licensed
to you under the terms of that license agreement. Datalogic and End User hereby
agree as follows:
1. Definitions.
1.1 "Affiliate" means a business entity currently existing or later acquired that controls,
is controlled by, or is under common control with Datalogic S.p.A.
1.2 "Documentation" means materials such as user's guides, program reference
guides, quick reference guides, manuals, or similar materials associated with or
related to the Datalogic Product, whether in printed, "online", or other form.
1.3 "Proprietary Information" means: (a) source code, object code, software, docu-
mentation, and any related internal design, system design, data base design,
algorithms, technology, technical data or information, implementation tech-
niques, and trade secrets related to the Software, (b) any other trade secrets
marked appropriately or identified as proprietary or confidential, and (c) any
information that End User, under the circumstances, should recognize as confi-
dential. Proprietary Information does not include any information that the
receiving party can establish was (1) in the public domain, (2) already in the
receiving party's possession or rightfully known prior to receipt, (3) rightfully
learned from a third party not in violation of any other's proprietary rights, or
(4) independently developed without access to Proprietary Information.
1.4 "Datalogic Product" means the Datalogic® Gryphon™ series scanner product,
including all embedded Software in and all Documentation related to such
product, which has been purchased or otherwise acquired by End User,
whether obtained directly or indirectly from Datalogic.
1.5 "Software" means any software or computer programs of Datalogic or its third
party licensors in machine readable form which is embedded in the Datalogic
Product, whether obtained directly or indirectly from Datalogic, including any
replacement, update, upgrade, enhancement or modification.
2. Scope Of License Granted.
2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license
to use the Software, solely on the Datalogic Product in which it is embedded
("designated Datalogic Product"), in machine-readable form only, solely for
End User's internal business purposes. This Agreement does not convey own-
ership of the Software to End User. Title to the Software shall be and remain
with Datalogic or the third party from whom Datalogic has obtained a licensed
right. As used in this Agreement, the term "purchase" or its equivalents when
applied to the Software shall mean "acquire under license." End User is not
entitled to receipt or use of the source code to any Software.
2.2
End User shall not copy, modify, decompile, disassemble, reverse engineer, or
otherwise reproduce or remanufacture the Software, whether modified or
unmodified, nor sell, assign, sublicense, distribute, lend, rent, give, or other-
wise transfer the Software to any other person or organization, for purposes
other than as expressly provided in this Agreement, without Datalogic's prior
written consent.
3. Transfers, Support.
3.1
Any copying, installing, reproduction, remanufacture, reverse engineering,
electronic transfer, or other use of the Software on other than the designated
Datalogic Product will be a material breach of this Agreement. However, Data-
Gryphon™ I GBT4100
logic may elect not to terminate this Agreement or the granted licenses, but
instead may elect to notify End User that End User is deemed to have ordered
and accepted a license for each breaching use. End User shall pay Datalogic
the applicable list price for such licenses as of the date of such breach.
3.2
End User shall not sell, assign, sublicense, distribute, lend, rent, give, or other-
wise transfer the Datalogic Product to any third party unless such third party
agrees with Datalogic in writing to be bound by the terms and conditions of
this Agreement. Any such transfer of the Datalogic Product absent such agree-
ment shall be null and void.
3.3
End User may obtain support for Software from Datalogic at Datalogic's stan-
dard support fees and under Datalogic's standard support terms and condi-
tions in effect at the time the support is requested.
4. Intellectual Property.
End User acknowledges that the Software constitutes valuable trade secrets of Data-
logic or Datalogic's third party licensors and that the Software is protected by intellec-
tual property laws and treaties. The license set forth in this Agreement does not transfer
to End User any ownership of Datalogic's or its third party licensors' copyrights, patents,
trademarks, service marks, trade secrets, or other intellectual property rights and End
User shall have no right to commence any legal actions to obtain such rights. End User
shall not remove, modify, or take any other action that would obscure any copyright,
trademark, patent marking, or other intellectual property notices contained in or on the
Datalogic Product.
5. Proprietary Information.
5.1
End User acknowledges that Proprietary Information is the confidential, pro-
prietary, and trade secret property of Datalogic and Datalogic's third party
licensors and End User acquires no right or interest in any Proprietary Informa-
tion.
5.2
End User shall not disclose, provide, or otherwise make available the Proprie-
tary Information of Datalogic or its third party licensors to any person other
than End User's authorized employees or agents who are under confidentiality
agreement, and End User shall not use the Proprietary Information other than
in conjunction with use of the Datalogic Product exclusively for End User's
internal business purposes. End User shall take steps to protect the Proprietary
Information no less securely than if it were End User's own intellectual prop-
erty.
5.3
The provisions of this Proprietary Information Section shall survive and con-
tinue for five (5) years after the termination of this Agreement.
6. Limited Warranty.
6.1
Datalogic warrants that, under normal use and operation, the Datalogic Prod-
uct will conform substantially to the applicable Documentation for the period
specified in the Documentation. During this period, for all reproducible non-
conformities for which Datalogic has been given written notice, Datalogic will
use commercially reasonable efforts to remedy nonconformities verified by
Datalogic. End User agrees to supply Datalogic with all reasonably requested
information and assistance necessary to help Datalogic in remedying such
nonconformities. For all defects reported to Datalogic within the warranty
period, Datalogic's liability is limited to providing End User with one copy of
corrections or responding to End User's problem reports according to Data-
logic's standard assistance practices. Datalogic does not warrant that the prod-
uct will meet End User's requirements or that use of the product will be
uninterrupted or error free, or that Datalogic's remedial efforts will correct any
nonconformance. This limited warranty does not cover any product that have
been subjected to damage or abuse, whether intentionally, accidentally, or by
neglect, or to unauthorized repair or unauthorized installation, and shall be
void if End User modifies the product, uses the product in any manner other
than as established in the Documentation, or if End User breaches any of the
provisions of this Agreement.
6.2
EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PRO-
VIDED "AS IS" AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND,
EXPRESS OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCT,
AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABIL-
ITY AND FITNESS FOR A PARTICULAR PURPOSE.
7. Infringement.
7.1
Datalogic will defend End User against any claim in a lawsuit that the Datalogic
Product furnished hereunder infringe a United States patent or copyright of a
third party and Datalogic will pay any damages finally awarded against End
User by a court of competent jurisdiction that are attributable to such claim or
will pay End User's part of any settlement that is attributable to such claim,
Quick Reference Guide
3
provided, that 1) End User notifies Datalogic promptly in writing of the claim,
2) Datalogic controls the defense or settlement of the claim, and 3) End User
cooperates fully with Datalogic in such defense or settlement. All notices of a
claim should be sent to Datalogic Scanning, Inc., Legal Department, 959 Terry
Street, Eugene, OR 97402.
7.2
In the defense or settlement of any such claim, Datalogic may, at its option, 1)
procure for End User the right to continue using the Datalogic Product, 2)
modify the Datalogic Product so that it becomes non-infringing, 3) replace the
Datalogic Product with an equivalent product not subject to such claim, or 4)
provide End User an opportunity to return the Datalogic Product and receive a
refund of the purchase price paid, less a reasonable allowance for use.
7.3
Datalogic shall have no liability to End User for claims of infringement based
upon 1) the use of any Datalogic Product in combination with any product
which Datalogic has not either furnished or authorized for use with such Data-
logic Product 2) the use of any Datalogic Product designed, manufactured, or
modified to the specifications of End User, or 3) End User's modification of the
Datalogic Product without written authorization from Datalogic.
7.4
THE FOREGOING STATES DATALOGIC'S COMPLETE AND ENTIRE OBLIGATION
CONCERNING CLAIMS OF PATENT, COPYRIGHT, OR OTHER INTELLECTUAL
PROPERTY INFRINGEMENT, CANCELS AND SUPERCEDES ANY PRIOR AGREE-
MENTS, WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING
SUCH CLAIMS, AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST, CON-
TEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PAR-
TIES, WHETHER ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE
WRITING SIGNED BY BOTH PARTIES.
8. Limitation Of Liability.
EXCEPT AS PROVIDED IN SECTION 7, DATALOGIC SHALL NOT BE LIABLE FOR ANY CLAIMS
AGAINST END USER BY ANY OTHER PARTY. IN NO EVENT SHALL DATALOGIC'S LIABILITY
FOR DAMAGES, IF ANY, WHETHER BASED UPON CONTRACT, TORT (INCLUDING NEGLI-
GENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS,
EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO
CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR
LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER
SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT, INCIDENTAL, PUNITIVE, EXEMPLARY,
OR OTHER SIMILAR DAMAGES, EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBIL-
ITY OF SUCH DAMAGES.
9. Government Restricted Rights; International Use.
9.1
Use, duplication, or disclosure of the Software by the U.S. Government is sub-
ject to the restrictions for computer software developed at private expense as
set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or
52.227-19 or in the Rights in Technical Data and Computer Software clause at
DFARS 252.227-7013(c)(1)(ii), whichever is applicable.
9.2
If End User is using the Datalogic Product outside of the United States, End
User must comply with the applicable local laws of the country in which the
Datalogic Product is used, with U.S. export control laws, and with the English
language version of this Agreement. The provisions of the "United Nations
Convention on International Sale of Goods" shall not apply to this Agreement.
10. Termination.
10.1
Either party may terminate this Agreement or any license granted under this
Agreement at any time upon written notice if the other party breaches any
provision of this Agreement.
10.2
Upon termination of this Agreement, End User immediately shall cease using
any nonembedded software and shall return to Datalogic or destroy all non-
embedded software covered by this Agreement, and shall furnish Datalogic
with a certificate of compliance with this provision signed by an officer or
authorized representative of End User. For embedded software, End User
agrees to sign a waiver prepared by Datalogic concerning further use of the
embedded Software. End User's resumed or continued use of the embedded
Software after termination shall constitute End User's agreement to be bound
by the terms and conditions of this Agreement for such use.
11. General Provisions.
11.1 Entire Agreement; Amendment. This document contains the entire agreement
between the parties relating to the licensing of the Software and supersedes
all prior or contemporaneous agreements, written or oral, between the parties
concerning the licensing of the Software. This Agreement may not be
changed, amended, or modified except by written document signed by Data-
logic.
11.2 Notice. All notices required or authorized under this Agreement shall be given in
Software Product Policy
4
Gryphon™ I GBT4100
writing, and shall be effective when received, with evidence of receipt. Notices
to Datalogic shall be sent to the attention of Contract Administration, Data-
logic Scanning, Inc., 959 Terry Street, Eugene, OR 97402, or such other address
as may be specified by Datalogic in writing.
11.3 Waiver. A party's failure to enforce any of the terms and conditions of this Agree-
ment shall not prevent the party's later enforcement of such terms and condi-
tions.
11.4 Governing Law; Venue: This Agreement and the rights of the parties hereunder
shall be governed by and construed in accordance with the laws of the State of
Oregon U.S.A, without regard to the rules governing conflicts of law. The state
or federal courts of the State of Oregon located in either Multnomah or Lane
counties shall have exclusive jurisdiction over all matters regarding this Agree-
ment, except that Datalogic shall have the right, at its absolute discretion, to
initiate proceedings in the courts of any other state, country, or territory in
which End User resides, or in which any of End User's assets are located.
11.5 Attorneys' Fees. In the event an action is brought to enforce the terms and condi-
tions of this Agreement, the prevailing party shall be entitled to reasonable
attorneys' fees, both at trial and on appeal.
- END -
Software Product Policy
Datalogic reserves the right to ship its products with the latest
version of software/firmware available. This provides our custom-
ers with the very latest in Datalogic software technology.
The only exception to this policy is when the buyer has a signed
contract with Datalogic that clearly defines the terms and condi-
tions for making software/firmware changes in products shipped
to the buyer.
Customers Under Software Support
Customers that elect to subscribe to Datalogic Software Mainte-
nance and Support Agreement will receive 30 days advance noti-
fication of: (1) the release of a new software version; and/or (2)
discontinuation of any prior software version that will no longer
be supported. Datalogic will provide maintenance for a fee that
will assist customers in transitioning to the next software version.
If a customer is currently using the software version being discon-
tinued, the customer may elect to transition to any one of the
newer versions, depending on the hardware in use.
To arrange for a Software Maintenance and Support Agreement
please contact your Datalogic sales person.
Quick Reference Guide
5
Setting Up the Reader
Follow the steps below to connect and get your reader up and
communicating with its host.
1.
Configure the Base Station starting on this page.
2.
Charge the Batteries (see page 11).
3.
Link to the Base Station (see page 16).
4.
Select the Interface Type (see page 18).
5.
Configure the Reader starting on page 30 (optional,
depends on settings needed).
Configuring the Base Station
The base charger/station may be configured in desk application to
hold the reader in two different positions, either a horizontal or
standing position, in order to provide the most comfortable use
depending on needs.
Changing the Base Station Position
The base station is configured by installing one of two sets of me-
chanical parts that come with the cordless kit. The default mounts
(shown below) provide three options: vertical (wall) mounting,
standing (45°), or horizontal mounting with a higher mechanical
retention of the scanner. Use the other mounts only for horizontal
mounting, with lower retention of the scanner. The different
parts may be interchanged to customize retention preferences.
A tool such as a rigid pen or a flat screwdriver can be used
to change the mounts. Do not allow it to touch the con-
tacts.
Standing
Horizontal
Configuring the Base Station
6
Gryphon™ I GBT4100
1.
Insert the appropriate parts for the desired base station
position, as shown below.
2.
Using your thumbs, push open the plastic tabs on the
bottom of the base to free the wing holders.
Standing,
Horizontal
Horizontal
or Vertical
Only
Tab
Tab
Connecting the Base Station
Quick Reference Guide
7
3.
The stand can now be repositioned in either horizontal
or standing position.
Connecting the Base Station
Figure 1 shows how to connect the Base Station to a terminal, PC
or other host device. Turn off the host before connection and con-
sult the manual for that equipment (if necessary) before proceed-
ing. Connect the interface cable before applying power to the Base
Station.
Base Station Connection and Routing: Fully insert the Power Ca-
ble and Interface (I/F) Cable connectors into their respective ports
in the underside of the Base Station (see Figure 1). Then connect
to an AC Adapter, and plug the AC power cord into the (wall)
outlet.
NOTE
Gryphon BT can also be Powered by the Terminal. The
external power supply is recommended but not necessary.
When powered by the Terminal, the battery charger is
automatically set as Slow charge.
Horizontal
Standing
Connecting the Base Station
8
Gryphon™ I GBT4100
Figure 1. Connecting the Base Station
Securing the DC Power Cord (Optional)
The DC power cord for the adapter can be secured to the bottom
of the base in order to maximize the mechanical retention of the
cable itself. The routing of the power cord can be changed to ac-
commodate the base station positioning: horizontal, stand or wall
mounting. The cables can be looped around to the front of the
Base Station, or fed directly out the back of the Base Station, as
shown in Figure 2 on page 8.
Figure 2. Options for routing the DC cord
Please refer to the arrows depicted on the bottom of the base when
placing the cables, detailed in Figure 3.
Base
Station
I/F Cable
AC/DC
Adapter
DC Power
Cord
Wall plug
Connector
Connecting the Base Station
Quick Reference Guide
9
Figure 3. Arrows showing routing
Host Connection: Verify before connection that the reader’s cable
type is compatible with your host equipment. Most connections
plug directly into the host device as shown in Figure 4 on page 9.
Keyboard Wedge interface cables have a ‘Y’ connection where its
female end mates with the male end of the cable from the key-
board and the remaining end at the keyboard port on the termi-
nal/PC.
Figure 4. Connecting to the Host
Power Connection : Plug the AC Adapter in to an approved AC
wall socket with the cable facing downwards (as shown in Figure
1) to prevent undue strain on the socket.
U
S
B
I
B
M
K
e
y
b
o
a
rd
W
e
d
g
e
W
a
n
d
or...
or...
or...
Connecting the Base Station
10
Gryphon™ I GBT4100
Disconnecting the Cable: To detach the cable, insert a paper clip
or similar object into the hole on the base, as shown in Figure 5.
Figure 5. Disconnecting the Cable
Using the BC40xx™ Radio Base
Radio Base LEDs
LEDs on the Gryphon I Base provide information about the Bases
well as battery charging status, as shown in Figure 6.
Figure 6. Gryphon I Base LEDs
The following table describes the significance of each LED.
NOTE
Gryphon BT can also be Powered by the Terminal. The exter-
nal power supply is recommended but not necessary. When
powered by the Terminal, the battery charger is automati-
cally set as Slow charge.
Insert
Paper Clip
YELLOW LED
RED LED —
GREEN LED
BUTTON
Charging the Batteries
Quick Reference Guide
11
Table 1. Radio Base LEDs
The button can be used to force device connection via the Data-
logic Aladdin Software tool, and for paging the scanner when it is
activated. Refer to the Gryphon I Product Reference Guide
(PRG) for a more detailed explanation.
Charging the Batteries
To charge the battery, simply insert the Gryphon into the base.
The LEDs on the base (shown in Table 1 above) will indicate the
status of the battery.
LED
STATUS
Power on / Data
Yellow On = Base is powered
Yellow Blinking = Base receives data and
commands from the Host or the Reader.
Charging
Red On = the Battery is charging.
Charge completed
Green On = the Battery is completely charged.
Charging +
Charge completed
Red and Green Blinking together = the Reader
is not correctly placed onto the Base.
NOTE
Before using the Battery, read “Battery Safety” in the
following section. Datalogic recommends annual
replacement of rechargeable battery packs to ensure
maximum performance.
Charging the Batteries
12
Gryphon™ I GBT4100
Battery Safety
To install, charge and/or do any other action on the battery, fol-
low the instructions in this manual.
WARNING
Do not discharge the battery using any device except
for the scanner. When the battery is used in devices
other than the designated product, it may damage the
battery or reduce its life expectancy. If the device
causes an abnormal current to flow, it may cause the
battery to become hot, explode or ignite and cause
serious injury.
Lithium-ion battery packs may get hot, explode or
ignite and cause serious injury if exposed to abusive
conditions. Be sure to follow the safety warnings
listed on the following page.
WARNING
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and nega-
tive terminal of the battery pack to each other
with any metal object (such as wire).
• Do not carry or store the battery pack together
with metal objects.
• Do not pierce the battery pack with nails, strike it
with a hammer, step on it or otherwise subject it
to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or
allow the battery to get wet.
• Do not apply voltages to the battery pack con-
tacts.
In the event the battery pack leaks and the fluid gets
into your eye, do not rub the eye. Rinse well with water
and immediately seek medical care. If left untreated,
the battery fluid could cause damage to the eye.
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) tem-
perature range.
Use only the authorized power supplies, battery pack,
chargers, and docks supplied by your Datalogic reseller.
The use of any other power supplies can damage the
device and void your warranty.
Do not disassemble or modify the battery. The battery
contains safety and protection devices, which, if dam-
aged, may cause the battery to generate heat, explode
or ignite.
Charging the Batteries
Quick Reference Guide
13
As with other types of batteries, Lithium-Ion (LI) batteries will
lose capacity over time. Capacity deterioration is noticeable after
one year of service whether the battery is in use or not. It is diffi-
cult to precisely predict the finite life of a LI battery, but cell man-
ufacturers rate them at 500 charge cycles. In other words, the
batteries should be expected to take 500 full discharge / charge cy-
cles before needing replacement. This number is higher if partial
discharging / recharging is adhered to rather than full / deep dis-
charging,
The typical manufacturer advertised useful life of LI batteries is
one to three years, depending on usage and number of charges,
etc., after which they should be removed from service, especially
in mission critical applications. Do not continue to use a battery
that is showing excessive loss of capacity, it should be properly re-
cycled / disposed of and replaced. For most applications, batteries
should be replaced after one year of service to maintain customer
satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in
comply with European Directive 2006/66/EC, 2002/95/EC,
2002/96/EC and subsequent modifications, US and China regu-
latory and others laws and regulations about the environment.
CAUTION
Do not place the battery in or near fire, on stoves or
other high temperature locations.
Do not place the battery in direct sunlight, or use or
store the battery inside cars in hot weather. Doing so
may cause the battery to generate heat, explode or
ignite. Using the battery in this manner may also result
in a loss of performance and a shortened life expec-
tancy.
CAUTION
Do not place the battery in microwave ovens, high-pres-
sure containers or on induction cookware.
Immediately discontinue use of the battery if, while
using, charging or storing the battery, the battery emits
an unusual smell, feels hot, changes color or shape, or
appears abnormal in any other way.
Do not replace the battery pack when the device is
turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Charging the Batteries
14
Gryphon™ I GBT4100
Replacing the Batteries
Use the following procedure to change the reader’s battery:
1.
With a screwdriver, unscrew the battery cover screw.
2.
Unplug the three screws securing the battery holder, and
unplug the white connector.
NOTE
Before proceeding, read “Battery Safety” on the
preceding pages. Datalogic recommends annual
replacement of rechargeable battery packs to
ensure maximum performance.
Connector
Screw
Screw
Screw
Charging the Batteries
Quick Reference Guide
15
3.
Carefully lift out the gold contacts circuit, and remove
the battery holder while letting the white connector pass
through the hole in the battery holder (as shown below).
4.
Remove the old battery from its place (if present), and
insert the new battery in the same position.
5.
Replace the battery holder, plug in the connector and
return the contacts circuit to its previous location.
6.
Insert the cover in the handle and screw it back into
place.
NOTE
When inserting the new battery into the handle, take care
to position the battery and the connector as shown.
Pass-through
hole
Gold
contacts
circuit
Linking the Reader
16
Gryphon™ I GBT4100
Linking the Reader
Link Datalogic RF Devices to Base
For RF devices, before configuring the interface it is necessary to
link the handheld with the base.
To link the handheld and the base, press the trigger to wake it and
place it on the base. If the reader was previously linked to another
base, you must first scan the Unlink barcode before re-linking to
the new base.
Link Scanner to Bluetooth Adapater
1.
Install any drivers provided with the Bluetooth adapter.
2.
Scan the Enable RF Link to Server label below to make the
scanner visible to the host computer.
3.
Use the host computer’s Bluetooth manager to “Discover
new devices” and select "Datalogic Scanner." If you
receive an error message, it may be necessary to disable
security on the device.
4.
Use an RS-232 terminal program to see incoming data
on the port designated by the computer's Bluetooth
manager.
Unlink
Enable RF Link to Server
Linking the Reader
Quick Reference Guide
17
System and Network Layout
Typical Setup with Cradle and Host
Figure 7. Reader Layout
Selecting the Interface Type
18
Gryphon™ I GBT4100
Selecting the Interface Type
Upon completing the physical connection between the reader and
its host, proceed directly to Interface Selection on page 18 for in-
formation and programming for the interface type the reader is
connected to (for example: RS-232, Keyboard Wedge, USB, etc.)
and scan the appropriate barcode to select your system’s correct
interface type.
Interface Selection
Each reader model will support one of the following sets of host
interfaces:
General Purpose Models: RS-232, RS-232 OPOS, USB, Key-
board Wedge, Wand.
Retail Point of Sale Models : RS-232, RS-232 OPOS, USB, IBM
46XX.
Information and programming options for each interface type are
provided in this section.
Configuring the Interface
Scan the programming barcode which selects the appropriate in-
terface type matching the system the reader will be connected to.
If you need to customize additional settings and features associat-
ed with that interface, proceed to the corresponding chapter in
the Gryphon™ I PRG.
NOTE
Unlike some other programming features and options,
interface selections require that you scan only one pro-
gramming barcode label. DO NOT scan an ENTER/EXIT bar-
code prior to scanning an interface selection barcode.
Some interfaces require the scanner to start in the dis-
abled state when powered up. If additional scanner con-
figuration is desired while in this state, pull the trigger
and hold for 5 seconds. The scanner will change to a state
that allows programming with barcodes.
Selecting the Interface Type
Quick Reference Guide
19
RS-232
RS-232 standard interface
Select RS232-STD
RS-232 Wincor-Nixdorf
Select RS232-WN
RS-232 for use with OPOS/UPOS/JavaPOS
Select RS-232 OPOS
USB Com to simulate RS-232 standard interface
Select USB-COM-STDa
Selecting the Interface Type
20
Gryphon™ I GBT4100
IBM
IBM-46xx Port 5B reader interface
Select IBM-P5B
IBM-46xx Port 9B reader interface
Select IBM-P9B
USB-OEM
USB-OEM
(can be used for OPOS/UPOS/JavaPOS)
Select USB-OEM
a. Download the correct USB Com driver from www.datalogic.com
Selecting the Interface Type
Quick Reference Guide
21
Keyboard Interface
Use the programming barcodes to select options for USB
Keyboard and Wedge Interfaces.
KEYBOARD
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/
Standard Key Encoding
Select KBD-AT
Keyboard Wedge for IBM AT PS2 with standard key encoding but without external
keyboard
Select KBD-AT-NK
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95
w/Alternate Key
Select KBD-AT-ALT
Keyboard Wedge for IBM AT PS2 with alternate key encoding but without exter-
nal keyboard
Select KBD-AT-ALT-NK
Selecting the Interface Type
22
Gryphon™ I GBT4100
KEYBOARD (continued)
PC/XT w/Standard Key Encoding
Select KBD-XT
Keyboard Wedge for IBM Terminal 3153
Select KBD-IBM-3153
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard
Select KBD-IBM-M
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard
Select KBD-IBM-MB
Keyboard Wedge for DIGITAL Terminals
VT2xx, VT3xx, VT4xx
Select KBD-DIG-VT
USB Keyboard with standard key encoding
Select USB Keyboard
Selecting the Interface Type
Quick Reference Guide
23
Scancode Tables
Reference the Gryphon™ I PRG for information about control
character emulation which applies to keyboard interfaces.
Country Mode
This feature specifies the country/language supported by the key-
board. Only the following interfaces support ALL Country
Modes.
•
USB Keyboard (without alternate key encoding)
•
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95
w/Std Key Encoding
•
Keyboard Wedge for IBM AT PS2 with standard key
encoding but without external keyboard
•
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95
without Alternate Key
•
Keyboard Wedge for IBM AT PS2 without alternate key
encoding but without external keyboard
All other interfaces support ONLY the following Country Modes:
U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.
KEYBOARD (continued)
USB Keyboard with alternate key encoding
Select USB Alternate Keyboard
USB Keyboard for Apple computers
Select USB-KBD-APPLE
WAND EMULATION
Wand Emulation
Select WAND
Selecting the Interface Type
24
Gryphon™ I GBT4100
COUNTRY MODE
ENTER/EXIT PROGRAMMING MODE
Country Mode = U.S.
Country Mode = Belgium
Country Mode = Britain
Country Mode = Croatia*
*Supports only the interfaces listed in the Country Mode feature
description
Selecting the Interface Type
Quick Reference Guide
25
COUNTRY MODE (continued)
Country Mode = Czechoslovakia*
Country Mode = Denmark*
Country Mode = France
Country Mode = Germany
Country Mode = Hungary*
Country Mode = Italy
*Supports only the interfaces listed in the Country Mode feature
description
Selecting the Interface Type
26
Gryphon™ I GBT4100
COUNTRY MODE (continued)
Country Mode = Japanese 106-key*
Country Mode = Norway*
Country Mode = Poland*
Country Mode = Portugal*
Country Mode = Romania*
Country Mode = Slovakia*
*Supports only the interfaces listed in the Country Mode feature
description
Selecting the Interface Type
Quick Reference Guide
27
COUNTRY MODE (continued)
Country Mode = Spain
Country Mode = Sweden
Country Mode = Switzerland*
*Supports only the interfaces listed in the Country Mode feature
description
Selecting the Interface Type
28
Gryphon™ I GBT4100
Caps Lock State
This option specifies the format in which the reader sends charac-
ter data. This applies to keyboard wedge interfaces. This does not
apply when an alternate key encoding keyboard is selected.
ENTER/EXIT PROGRAMMING MODE
Caps Lock State = Caps Lock OFF
Caps Lock State = Caps Lock ON
Caps Lock State = AUTO Caps Lock Enable
Selecting the Interface Type
Quick Reference Guide
29
Numlock
This option specifies the setting of the Numbers Lock (Numlock)
key while in keyboard wedge interface. This only applies to alter-
nate key encoding interfaces. It does not apply to USB keyboard.
ENTER/EXIT PROGRAMMING MODE
Numlock = Numlock key unchanged
Numlock = Numlock key toggled
Gryphon™ I GBT4100
Programming
The reader is factory-configured with a set of standard default fea-
tures. After scanning the interface barcode from the Interfaces sec-
tion, you can select other options and customize your reader
through use of the instructions and programming barcodes avail-
able in the Gryphon™ I Product Reference Guide (PRG). Check
the corresponding features section for your interface, and also the
Data Editing and Symbologies chapters of the PRG.
Using Programming Barcodes
This manual contains barcodes which allow you to reconfigure
your reader. Some programming barcode labels, like the Standard
Product Default Settings on page 30, require only the scan of that
single label to enact the change.
Other barcodes require the reader to be placed in Programming
Mode prior to scanning them. Scan an ENTER/EXIT barcode
once to enter Programming Mode; scan the desired parameter set-
tings; scan the ENTER/EXIT barcode again to accept your
changes, which exits Programming Mode and returns the reader
to normal operation.
Configure Other Settings
Additional programming barcodes are available in the Gry-
phon™ I PRG to allow for customizing programming features. If
your installation requires different programming than the stan-
dard factory default settings, refer to the PRG.
Resetting Standard Product Defaults
Reference the PRG for a listing of standard factory settings. If you
aren’t sure what programming options are in your reader, or
you’ve changed some options and want the factory settings re-
stored, scan the Standard Product Default Settings barcode below to
copy the factory configuration for the currently active interface to
the current configuration.
NOTE
Factory defaults are based on the interface type. Con-
figure the reader for the correct interface before scan-
ning this label.
Standard Product Default Settings
Quick Reference Guide
31
Stand Detection
The following labels control how the scanner behaves when it is
placed into a cradle or stand that has the hardware to support au-
tomatic stand detection.
Switch to Stand Mode: Automatically switches the scanner to
Stand Mode when the scanner is placed in the stand.
Switch to Flashing: Automatically switches the scanner to Flash
Mode when the scanner is placed in the stand.
Switch to Always On: Automatically switches the scanner to Al-
ways On mode when the scanner is placed in the stand.
Ignore Autorecognition: Disables mode switching when the scan-
ner is placed in a stand.
Switch to Stand Mode
Switch to Flashing
Switch to Always On
Ignore Autorecognition
Gryphon™ I GBT4100
Technical Specifications
The following table contains Physical and Performance Charac-
teristics, User Environment and Regulatory information.
Item
Description
Physical Characteristics
Color
White/Gray
Black/Gray
Dimensions
Height 7.1”/181 mm
Length 3.9”/100 mm
Width 2.8”/71 mm
Weight (without cable)
Approximately
8.7 ounces/246 g (reader with display)
8.7 ounces/246 g (base charger)
Electrical Characteristics
Battery Type
Li-Ion battery pack
Charge time for full charge
from full discharge
4 hours with external power supply adaptera
max 22h hours with Host power
(in this case no supply adapter is needed)a
Operating autonomy
(continuous reading)
30,000 reads
(typical)
Cradle consumption
and DC input supply range
Volt 4.75-14 VDC; Power <8Wb;
Imax 500mA when in host/bus powered modeb.
Performance Characteristics
Light Source
LEDs
Roll (Tilt) Tolerance
± 35° from normal
Pitch Tolerance
± 65°
Skew (Yaw) Tolerance
± 65°
Field of View
10” (25.4cm) wide at 12.5” (31.8cm) from the reader
Depth of Field (Typical)c
3 mil – 2.9” to 4.7” (7.5cm to 12cm)
13 mild – 1.2” to 23.6” (3cm to 60cm)
20 mil – 1.2” to 31.5” (3cm to 80cm)
Quick Reference Guide
33
Minimum Element Width
3 mil
Print Contrast Minimum
15% minimum reflectance
Decode Capability
UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Phar-
macode 39; Code 128; C128 ISBT; Code 128 add-ons; I 2
of 5; Standard 2 of 5; Code 11;Codabar; EAN 128; Code
93; MSI; GS1 DataBar™ Omnidirectional, GS1 DataBar™
Limited, GS1 DataBar™ Expanded; Code4, Code5.
Interfaces Supportedd
RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM
46xx (ports5B and 9B), USB Com Std., USB Keyboard,
USB Alternate Keyboard, USB OEM, Keyboard Wedge
(AT with or w/o Alternate Key, IBM AT PS2 with or w/o
Alternate Key, PC-XT, IBM 3153, IBM Terminals 31xx,
32xx,34xx, 37xx make only and make break keyboard,
Digital Terminals VT2x, VT3xx, VT4xx, and Apple) and
Wand Emulation.
User Environment
Operating Temperature
32° to 122° F (0° to 50° C)
Charging Temperature
32° to 104° F (0° to 40° C)
Storage Temperature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity,
non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.8 meters
(5.9 feet) to concrete
Ambient Light Immunity
Up to 100,000 Lux
Contaminants Spray/rain
Dust/particulates
IEC 529-IP52 (scanner only)
ESD Level
16 KV
a.
Charge Times are much lower when battery is within daily typical operat-
ing condition.
b.
Typical input current measured under factory default configuration.
c.
13 mils DOF based on EAN. All others are Code 39. All labels grade A, typi-
cal environmental light, 20°C, label inclination 10°
d.
See Interface Selection on page 18 for a listing of available interface sets
by model type.
Item
Description
Gryphon™ I GBT4100
Item
Description
Regulatory
Electrical Safety
UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
Obtained:
Europe - CE, Australia - C-tick, Russia – GOST,
USA/CANADA – FCC/IC, Japan – JRF/VCCI
Pending:
Mexico - NOM + Cofetel, South Korea - KCC,
Brazil - ANATEL, Argentina - CNC
LED class safety
IEC Class 1
Radio Features
Frequency Range
2400 to 2483.5 MHz
Range (in open air)
30 m
LED and Beeper Indications
Quick Reference Guide
35
LED and Beeper Indications
The reader’s beeper sounds and its LED illuminates to indicate
various functions or errors on the reader. An optional “Green
Spot” also performs useful functions. The following tables list
these indications. One exception to the behaviors listed in the ta-
bles is that the reader’s functions are programmable, and may or
may not be turned on. For example, certain indications such as
the power-up beep can be disabled using programming barcode
labels.
INDICATION
DESCRIPTION
LED
BEEPER
Power-up Beep
The reader is in
the process of
powering-up.
Reader beeps
four times at
highest fre-
quency and vol-
ume upon
power-up.
Good Read Beep
A label has been
successfully
scanned by the
reader.
LED behavior
for this indica-
tion is configu-
rable via the
feature “Good
Read: When to
Indicate”
(see the PRG for
information.)
The reader will
beep once at cur-
rent frequency,
volume, mono/
bi-tonal setting
and duration
upon a success-
ful label scan.
ROM Failure
There is an error
in the reader's
software/pro-
gramming
Flashes
Reader sounds
one error beep at
highest volume.
Limited Scan-
ning Label Read
Indicates that a
host connection
is not established
when the IBM or
USB interface is
enabled.
N/A
Reader 'chirps'
six times at the
highest fre-
quency and cur-
rent volume.
Reader Active
Mode
The reader is
active and ready
to scan.
The LED is lit
steadilya
N/A
Quick Reference Guide
36
Reader
Disabled
The reader has
been disabled by
the host.
The LED blinks
continuously
N/A
Green Spot is on
continuously
While in Stand
Mode or Trigger
Stand Mode the
green spot shall
be on while in
stand watch
state.
N/A
N/A
Green Spota
flashes momen-
tarily
Upon successful
read of a label,
the software shall
turn the green
spot on for the
time specified by
the configured
value.
N/A
N/A
Programming Mode - The following indications ONLY occur when the
reader is in Programming Mode.
Label Program-
ming Mode
Entry
A valid program-
ming label has
been scanned.
LED blinks con-
tinuously
Reader sounds
four low fre-
quency beeps.
Label Program-
ming Mode
Rejection of
Label
A label has been
rejected.
N/A
Reader sounds
three times at
lowest fre-
quency and cur-
rent volume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where
multiple labels
must be scanned
to program one
feature, this indi-
cation acknowl-
edges each
portion as it is
successfully
scanned.
N/A
Reader sounds
one short beep at
highest fre-
quency and cur-
rent volume.
INDICATION
DESCRIPTION
LED
BEEPER
Quick Reference Guide
37
Error Codes
Upon startup, if the reader sounds a long tone, this means the
reader has not passed its automatic Selftest and has entered FRU
(Field Replaceable Unit) isolation mode. If the reader is reset, the
sequence will be repeated. The following table describes the LED
flashes/beep codes associated with an error found.
Label Program-
ming Mode
Acceptance of
Programming
Configuration
option(s) have
been successfully
programmed via
labels and the
reader has exited
Programming
Mode.
N/A
Reader sounds
one high fre-
quency beep and
4 low frequency
beeps followed
by reset beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has
been scanned.
N/A
Reader sounds
two times at low
frequency and
current volume.
a.
Except when in sleep mode or when a Good Read LED Duration other than 00
is selected
NUMBER OF
LED
FLASHES/
BEEPS
ERROR
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for
assistance
2
Interface PCB
4
Reader Module
5
Laser Pointer (if so
equipped)
6
Digital PCB
14
CPLD/Code Mismatch
INDICATION
DESCRIPTION
LED
BEEPER
Base Station Indications
38
Gryphon™ I GBT4100
Base Station Indications
INDICATION
LEDS
Power-up Complete
Yellow LED on
Reader Disabled by the HOST or the com-
munication with HOST is not established
Yellow LED blinking ~1Hz
Data/labels are transmitted to the HOST
Yellow LEDs turned off for
100mSec
Programming Mode
Yellow LED blinks quickly
Configuration alignment with the HH is in
progress
Red LED blinks quickly
Battery charger in progress
Red LED on
Battery charger complete
Green LED on
Battery charger error
Green LED and Red LEDs blink
alternatively ~1Hz
No HH is placed on the cradle
Red and Green LEDs off
Statement of Agency Compliance
Quick Reference Guide
39
Regulatory Information
All models are designed to be compliant with rules and regula-
tions in locations they are sold and will be labeled as required.
Any changes or modifications to equipment, not expressly ap-
proved by Datalogic could void the user's authority to operate the
equipment.
Statement of Agency Compliance
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any in-
terference received, including interference that may cause unde-
sired operation.
FCC Class B Compliance Statement
The user is cautioned that changes or modifications not expressly
approved by the part responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the
limits for a Class B digital device pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. How-
ever, there is no guarantee that interference will not occur in a par-
ticular installation. If this equipment does cause harmful
interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encour-
aged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and
receiver.
•
Connect the equipment into an outlet on a circuit differ-
ent from that to which the receiver is connected.
•
Consult the dealer or an experienced radio or television
technician for help.
Statement of Agency Compliance
40
Gryphon™ I GBT4100
FCC RF Radiation Exposure Statement
To comply with FCC RF exposure compliance requirements, for
mobile configurations, a separation distance of at least 20 cm
must be maintained between the antenna of this device and all
persons.
This device must not be co-located or operating in conjunction
with any other antenna or transmitter.
Canadian Notice
This equipment does not exceed the Class B limits for radio noise
emissions as described in the Radio Interference Regulations of
the Canadian Department of Communications.
Le present appareil numerique n’emet pas de bruits radioelec-
triques depassant les limites applicables aux appareils numeriques
de la classe B prescrites dans le Reglement sur le brouillage radio-
electrique edicte par le ministere des Communications du Cana-
da.
Power Supply
This device is intended to be connected to a UL Listed/CSA Cer-
tified computer which supplies power directly to the reader or else
be supplied by UL Listed/CSA Certified Power Unit marked
“Class 2” or LPS power source rated 5-14V minimum 900mA,
which supplies power directly to the Base/Charger via the power
connector of the Base itself.
CAUTION
Exposure to Radio-Frequency Radiation
CAUTION
Do not attempt to open or otherwise service any compo-
nents in the optics cavity. Opening or servicing any part
of the optics cavity by unauthorized personnel may vio-
late laser safety regulations.
Quick Reference Guide
41
Imager Labeling
Sample labels are shown here to illustrate their location only.
Please view the labels on your product for actual details.
Cleaning
Exterior surfaces and scan windows exposed to spills, smudges or
debris accumulation require periodic cleaning to ensure best per-
formance during scanning operations. Contacts on the scanner
and the base should also be cleaned as needed to ensure a good
connection.
Always use a soft, lint-free cloth or lens tissue dampened with iso-
propyl alcohol (or equivalent) or water-based window cleaner. A
cotton swab may be used for hard-to-reach areas.
CAUTION
Do not use abrasive cleansing agents or abrasive pads to
clean scan windows or plastics.
Do not spray or pour liquids directly onto the unit.
R
C
US
239045
10
DATALOGIC SCANNING INC.
EUGENE , OREGON
USA
SEE P ACK AGE FOR
PATENT LISTING
CLAS S 1 LED PRODUCT
N263
Scanner Regulatory Label
Base Station Label
Gryphon™ I GBT4100
WEEE Statement
English
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE),
please refer to the website at www.scanning.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche
consultare il sito Web www.scanning.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques (WEEE),
veuillez consulter le site internet www.scanning.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE) erhalten
Sie auf der Webseite www.scanning.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los residuos del
equipo eléctrico y electrónico (WEEE), visite la página Web
www.scanning.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e
Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web
www.scanning.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考
Datalogic 公司的网站www.scanning.datalogic.com/。
Japanese
廃電気電子機器(WEEE) の処理についての関連事項は
Datalogic のサイト www.scanning.datalogic.com をご参照下さ
い。
Waste Electrical and Electronic Equipment
(WEEE) Statement
Quick Reference Guide
43
Warranty
Datalogic warrants to Customer that Datalogic's products will be free from defects in
materials and workmanship for a period of one year from product shipment.
Datalogic Scanning Limited Factory
Warranty
Warranty Coverage
Datalogic Scanning (“Datalogic”) hardware products are warranted against defects in
material and workmanship under normal and proper use. The liability of Datalogic un-
der this warranty is limited to furnishing the labor and parts necessary to remedy any
defect covered by this warranty and restore the product to its normal operating con-
dition. Repair or replacement of product during the warranty does not extend the orig-
inal warranty term. Products are sold on the basis of specifications applicable at the
time of manufacture and Datalogic has no obligation to modify or update products
once sold.
If Datalogic determines that a product has defects in material or workmanship, Data-
logic shall, at its sole option repair or replace the product without additional charge
for parts and labor, or credit or refund the defective products duly returned to Data-
logic. To perform repairs, Datalogic may use new or reconditioned parts, compo-
nents, subassemblies or products that have been tested as meeting applicable
specifications for equivalent new material and products. Customer will allow Datalog-
ic to scrap all parts removed from the repaired product. The warranty period shall ex-
tend from the date of shipment from Datalogic for the duration published by Datalogic
for the product at the time of purchase (Warranty period). Datalogic warrants repaired
hardware devices against defects in workmanship and materials on the repaired as-
sembly for a 90 day period starting from the date of shipment of the repaired product
from Datalogic or until the expiration of the original warranty period, whichever is lon-
ger. Datalogic does not guarantee, and it is not responsible for, the maintenance of,
damage to, or loss of configurations, data, and applications on the repaired units and
at its sole discretion can return the units in the “factory default” configuration or with
any software or firmware update available at the time of the repair (other than the
firmware or software installed during the manufacture of the product). Customer ac-
cepts responsibility to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer must notify Datalog-
ic of the claimed defect before the expiration of the applicable Warranty period and
obtain from Datalogic a return authorization number (RMA) for return of the product
to a designated Datalogic service center. If Datalogic determines Customer’s claim is
valid, Datalogic will repair or replace product without additional charge for parts and
labor. Customer shall be responsible for packaging and shipping the product to the
designated Datalogic service center, with shipping charges prepaid. Datalogic shall
pay for the return of the product to Customer if the shipment is to a location within the
country in which the Datalogic service center is located. Customer shall be responsi-
ble for paying all shipping charges, duties, taxes, and any other charges for products
returned to any other locations. Failure to follow the applicable RMA policy, may re-
sult in a processing fee. Customer shall be responsible for return shipment expenses
for products which Datalogic, at its sole discretion, determines are not defective or
eligible for warranty repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i)
any product which has been damaged, modified, altered, repaired or
upgraded by other than Datalogic service personnel or its authorized
representatives;
(ii)
any claimed defect, failure or damage which Datalogic determines was
caused by faulty operations, improper use, abuse, misuse, wear and
tear, negligence, improper storage or use of parts or accessories not
approved or supplied by Datalogic;
(iii)
any claimed defect or damage caused by the use of product with any
other instrument, equipment or apparatus;
(iv)
any claimed defect or damage caused by the failure to provide proper
maintenance, including but not limited to cleaning the upper window in
accordance with product manual;
Gryphon™ I GBT4100
(v)
any defect or damage caused by natural or man-made disaster such
as but not limited to fire, water damage, floods, other natural disasters,
vandalism or abusive events that would cause internal and external
component damage or destruction of the whole unit, consumable
items;
(vi)
any damage or malfunctioning caused by non-restoring action as for
example firmware or software upgrades, software or hardware recon-
figurations etc.;
(vii)
the replacement of upper window/cartridge due to scratching, stains or
other degradation and/or
(viii)
any consumable or equivalent (e.g., cables, power supply, batteries,
keypads, touch screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this war-
ranty except to a purchaser or transferee of product. No attempted assignment or
transfer in violation of this provision shall be valid or binding upon Datalogic.
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR OTHERWISE, IN-
CLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANT-
ABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT.
DATALOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUS-
TOMER ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PROD-
UCTS UNDER THE ABOVE. THE REMEDY SET FORTH IN THIS WARRANTY
STATEMENT IS THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY FOR WAR-
RANTY CLAIMS. UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE
TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY IN-
CIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAG-
ES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE
POSSIBILITY OF SUCH DAMAGES.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic. Data-
logic shall assume risk of loss or damage for product in Datalogic’s possession. In the
absence of specific written instructions for the return of product to Customer, Data-
logic will select the carrier, but Datalogic shall not thereby assume any liability in con-
nection with the return shipment.
Ergonomic Recommendations
•
Reduce or eliminate repetitive motion
•
Maintain a natural position
•
Reduce or eliminate excessive force
•
Keep objects that are used frequently within easy reach
•
Perform tasks at correct heights
•
Reduce or eliminate vibration
•
Reduce or eliminate direct pressure
•
Provide adjustable workstations
•
Provide adequate clearance
•
Provide a suitable working environment
•
Improve work procedures.
CAUTION
In order to avoid or minimize the potential risk of ergo-
nomic injury follow the recommendations below. Consult
with your local Health & Safety Manager to ensure that you
are adhering to your company’s safety programs to prevent
employee injury.
Services and Support
Quick Reference Guide
45
Services and Support
Datalogic provides several services as well as technical support
through its website. Log on to www.scanning.datalogic.com and
click on the links indicated for further information.
Products
Search through the links to arrive at your product page where you
can download specific Manuals and Software & Utilities, includ-
ing:
•
Datalogic Aladdin™, a multi-platform utility program
that allows device configuration using a PC. It provides
RS-232 interface configuration as well as configuration
bar code printing.
Service & Support
•
Technical Support - Product documentation and pro-
gramming guides and Technical Support Department in
the world
•
Service Programs - Warranty Extensions and Mainte-
nance Agreements
•
Repair Services - Flat Rate Repairs and Return Material
Authorization (RMA) Repairs.
•
Downloads – Manuals & Documentation, Data Sheets,
Product Catalogues, etc.
Contact Us
•
Information Request Form and Sales & Service Network
declares that the
déclare que le
bescheinigt, daß das Gerät
declara que el
Gryphon GBT41xx-YY ; Cordless Barcode Reader
Gryphon BC 40X0-YY-BT ; Cordless Base station/Charger
sono conformi alle Direttiva del Consiglio Europeo sottoelencata:
are in conformity with the requirements of the European Council Directive listed below:
sont conforme aux spécifications des Directive de l'Union Européenne ci-dessous:
den nachstehenden angeführten Direktive des Europäischen Rats entsprechen:
cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente:
1999/5/EC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
DECLARATION OF CONFORMITY
EC-062
Rev.:1
Pag.:1 di 1
Datalogic Scanning Group Srl
Via S. Vitalino, 13
Lippo di Calderara di Reno (BO)
40012 Italy
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine modelle
y todos sus modelos
ETSI EN 301 489-17 v1.3.2, April 2008 : ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR
RADIO EQUIPMENT; PART 17: SPECIFIC CONDITIONS FOR 2,4 GHZ
WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE
RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING
SYSTEMS
ETSI EN 300 328-3 v1.7.1, October 2006 :
ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION
EQUIPMENT OPERATING IN THE 2,4 GHZ ISM BAND AND USING WIDE
BAND MODULATION TECHNIQUES; HARMONIZED EN COVERING
ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE
DIRECTIVE
EN 60950-1, December 2006 +
Amendment A11, March 2009:
INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS
Lippo di Calderara, October 29th, 2010
Ruggero Cacioppo
Quality Assurance Manager
10
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2009-2011 Datalogic Scanning, Inc.
820032414 (Rev. C)
October / 2011
www.scanning.datalogic.com
Australia
Datalogic Scanning Pty Ltd
Telephone: [61] (2) 9870 3200
[email protected]
France and Benelux
Datalogic Scanning SAS
Telephone: [33].01.64.86.71.00
[email protected]
Germany
Datalogic Scanning GmbH
Telephone: 49 (0) 61 51/93 58-0
[email protected]
India
Datalogic Scanning India
Telephone: 91- 22 - 64504739
[email protected]
Italy
Datalogic Scanning SpA
Telephone: [39] (0) 39/62903.1
[email protected]
Japan
Datalogic Scanning KK
Telephone: 81 (0)3 3491 6761
[email protected]
Latin America
Datalogic Scanning, Inc
Telephone: (305) 742-2206
[email protected]
Singapore
Datalogic Scanning Singapore PTE LTD
Telephone: (65) 6435-1311
[email protected]
Iberia
Datalogic Scanning SAS Sucursal en España
Telephone: 34 91 746 28 60
[email protected]
United Kingdom
Datalogic Scanning LTD
Telephone: 44 (0) 1582 791700
[email protected]